Specifications
SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 4/1/2013 C: \HASS74\ARLINGTON72 . SDF JOB TITLE: Arlington Heights Lot #72 WATER SUPPLY DATA SOURCE PRESS. PRESS . @ FLOW PRESS . @ DEMAND PREESS. RECEIV ED ' TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) APR 0 2 2013 8 118 . 0 54 . 0 12 3 0. 0 117 . 9 26. 8 51 .2 CITY OF TIGARD .T.-PS DIVISION AGGREGATE FLOW ANALYSIS: FF 2013-- DO DWI 15337 chw {B refs rI'd V, TOTAL FLOW AT SOURCE 26. 8 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0 . 0 GPM OTHER HOSE STREAM ALLOWANCES 0. 0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26. 8 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 9. 0 K= 4 . 90 7 . 0 13 . 0 2 9 . 0 K= 4 . 90 7 . 9 13 . 8 3 9. 5 - - - - 8 .2 - - - 4 19. 5 - - - - 21 . 0 - - - 5 8 . 0 - - - - 31 . 4 - - - 6 1 . 0 - - - - 35 . 8 - - - 7 1 . 0 - - - - 39. 8 - - - 8 0. 0 SOURCE 51.2 26. 8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 4/1/2013 C: \HASS74\ARLINGTON72 . SDF JOB TITLE: Arlington Heights Lot #72 PIPE DATA PIPE TAG Q (GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ . PT DISC. VEL (FPS) HW (C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -13 . 0 0. 874 PL 12 . 00 PF 1 . 4 1 9 . 0 4 . 9 7 . 0 13.0 6. 9 150 FTG T PE -0.2 3 9 . 5 0. 0 8 . 2 0.0 0 . 094 TL 15 . 11 PV Pipe: 2 -13 . 8 0 . 874 PL 1 . 50 PF 0 . 5 2 9 . 0 4 . 9 7 . 9 13. 8 7 . 4 150 FTG T PE -0. 2 3 9 . 5 0 . 0 8 . 2 0. 0 0 . 105 TL 4 . 61 PV Pipe: 3 -26. 8 0 . 874 PL 36. 00 PF 17 . 2 3 9. 5 0 . 0 8 .2 0.0 14 . 3 150 FTG 2E3T PE -4 . 3 4 19 . 5 0. 0 21 . 0 0.0 0 . 359 TL 47 . 80 PV Pipe: 4 -26. 8 0 . 874 PL 12 . 50 PF 5 . 4 4 19 . 5 0 . 0 21 . 0 0.0 14 . 3 150 FTG 2E PE 5 . 0 5 8 . 0 0 . 0 31 . 4 0.0 0. 359 TL 14 . 99 PV Pipe: 5 -26. 8 1 . 080 PL 7 . 00 PF 1. 4 5 8 . 0 0. 0 31 . 4 0 .0 9. 4 120 FTG ---- PE 3 . 0 6 1 . 0 0 . 0 35 . 8 0 . 0 0 . 194 TL 7 . 00 PV Pipe: 6 FIXED PRESSURE LOSS DEVICE 7 1 . 0 0 . 0 39. 8 0. 0 4 . 0 psi, 26. 8 gpm 6 1 . 0 0 . 0 35 . 8 0. 0 Pipe: 7 -26. 8 1 . 101 PL 94 . 00 PF 11 . 0 7 1 . 0 0 . 0 39. 8 0.0 9. 0 150 FTG ---- PE 0. 4 8 0 . 0 SRCE 51 . 2 (N/A) 0. 117 TL 94 . 00 PV NOTES: (1) Calculations were performed by the HASS 7 . 4 computer program under license no. 5010113212 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 (2) The system has been calculated to provide an average imbalance at each node of 0 . 005 gpm and a maximum imbalance at any node of 0 . 033 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 14 . 3 ft/sec at pipe 3 . (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD. PIP SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 4/1/2013 C: \HASS74\ARLINGTON72 . SDF JOB TITLE: Arlington Heights Lot #72 PAGE: * MATERIAL: S40 HWC: 120 -Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatV1v AlmChk DPV1v NPTee ' 0. 874 0 . 82 2 . 06 0 . 82 2 . 06 2 . 47 0. 41 4 . 11 4 . 11 2 . 06 1 . 080 2 . 30 5 . 76 2 . 30 5. 76 6. 91 1 . 15 11 . 52 11 . 52 5 . 76 1 . 101 2 . 53 6. 33 2 . 53 6. 33 7 . 59 1 . 27 12 . 66 12 . 66 6. 33 O ' W H WATER SUPPLY ANALYSIS A " 140.0 Static: 118 .00 psi Resid: 54.00 psi Flow: 1230.0 gpm y ,A r m LEGEND " N yo n H W 1 Available pressure P- 1 117 .95 psi @ 26.8 gpm w 2 Required pressure o G112.0 51.17 psi @ 26.8 gpm m A x ro m x U I-'. H w z G x E 0 m w P r o m R 84.0 (7 K H E S N M S K U o R > C E 56.0 H • 2 A n ( z p o > 9 i K i x )=/ H (n UJ 28.0 V) .A r H z ca H O 0. 0 z z ea N Ai M m 0 r'7 -14 . 7 I I 1 i I I 1 1 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) ttjco Fire Suppression & Building d ng Products rapidresponse Technical Services 800-381-9312 +1-401-781-8220 HOME FIRE SPRINKLER SYSTEM ff www.tyco-fire.com Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4,9 K-Factor General The Series LFII Residential Flat-Plate Concealed Pendent Sprinkler has a 4.9 Description (60,5)K-factor that provides the required residential flow rates at reduced pres- - The TYCO RAPID RESPONSE Series sures,enabling smaller pipe sizes and �{4} � LFII Residential Flat-Plate Concealed water supply requirements. 41. irgq Pendent Sprinklers(TY2524)are decora- This sprinkler has been designed with `'' tive,fast response,fusible solder sprin- heat sensitivity and water distribution t kiers designed for use in residential oc- characteristics proven to help in the con- cupancies such as homes, apartments, trol of residential fires and to improve dormitories, and hotels. the chance for occupants to escape or The Cover Plate/Retainer Assembly con- be evacuated. ,,- *, :., ;; ceals the sprinkler operating compo- The Series LFII Residential Flat-Plate .;. .i °I2- ic" nents above the ceiling.The flat profile Concealed Pendent Sprinklers are . of the Cover Plate provides the optimum shipped with a Disposable Protective aesthetically appealing sprinkler design. Cap.The Protective Cap protects the Additionally,the concealed design of the sprinkler during ceiling installation or _ -_ _ _Series_LFII_Residential Flat-Plate Con--__-finish:=After.ceilirig iristallatiorl=is colt-=---Technical • cealed Pendent Sprinklers provides 1/2 plete, the Protective Cap is removed inch(12,8 mm)vertical adjustment.This and the Cover Plate/Retainer Assem- Data adjustment provides a measure of flex- bly is installed. Removing the Protec- ibility when cutting fixed pipe drops. tive Cap is required for proper sprinkler Approvals The Series LFII Residential Flat-Plate performance. UL and C-UL Listed Concealed Pendent Sprinklers are in- NSF-61 Certified tended for use in the following systems: NOTICE The Series LFII Residential Flat-Plate • per NFPA 13D, wet pipe residential The Series LFII Residential Flat-Plate Concealed Pendent Sprinklers are only sprinkler systems for one-and two- Concealed Pendent Sprinklers(TY2524) listed with the Series LFII Concealed family dwellings and mobile homes; described herein must be installed and Cover Plates having a factory-applied •per NFPA 13R, wet pipe residential maintained in compliance with this doc- finish. sprinkler systems for pipe oc- ument and with the applicable standards cupnkler s up to and including four of the National Fire Protection Associa Maximum Working Pressure Lion,in addition to the standards of any 175 psi(12,1 bar) stories in height;and authorities having jurisdiction. Failure •per NFPA 13,wet pipe sprinkler sys- to do so may impair the performance Discharge Coefficient tems for the residential portions of of these devices. K=4.9 h arge GPM/psi'rz(70,6 LPM/bar's any occupancy. Owners are responsible for maintaining Temperature Rating their fire protection system and devices Sprinkler: 160°F(71°C) in proper operating condition. The in Cover Plate: 139°F(59°C) IMPORTANT stal ling contractor or sprinkler manu- Vertical Adjustment Always refer to Technical Data facfurershould be contacted with any 1/2 inch (12,7 mm) Sheet TFP700 for the `INSTALLER questions. WARNING" that provides cautions Finishes with respect to handling and instal- Model/Sprinkler Refer to the Ordering Procedure lation of sprinkler systems and corn- section. ponents. improper handling and in- Identification Physical - stallation can permanently damage y ' al Characteristics a sprinkler system or its components • Cover Plate/Retainer Assembly: and cause the sprinkler to fail to Number (SIN) • Cover Plate Copper operate in a fire situation or cause it TY2524 Ejection Spring . . . . Stainless Steel to operate prematurely. Retainer Brass Page 1 of 6 OCTOBER 2010 TFP443 • TFP443 Page 2 of 6 Horizontal Ceiling Sloped Ceiling Sloped Ceiling Minimum Flow(bland Minimum FlowNNand Minimum Flowro'and Residual Pressure Residual Pressure Residual Pressure Maximum Maximum (Maximum 2-inch rise (Greater than 2-inch rise (Greater than 4-inch rise Coverage Spacing for 12-inch run) up to maximum 4-inch up to maximum 8-inch Area I') rise for 12-inch run) rise for 12-inch run) 160°F(71°C) 160°F(71°C) 160°F(71°C) Sprinkler Sprinkler Sprinkler 12'x 12' 12' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (3,7 m x 3,7 m) (3,7 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 14'x 14' 14' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (4,3 m x 4,3 m) (4,3 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 16'x 16' 16' 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (4,9 m x 4,9 m) (4,9 m) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) • 18'x 18' 18' 17 GPM(64,3 LPM) 22 GPM(83,3 LPM) 22 GPM(83,3 LPM) (5,5 m x 5,5 m) (5,5 m) 12.0 psi(0,83 bar) 20.2 si(1,39 bar P ( bar) 20.2 psi(1,39 bar) 20'x 20' 20' 20 GPM(75,7 LPM) 24 GPM(90,8 LPM) 24 GPM(90,8 LPM) (6,1 m x 6,1 m) (6,1 m) 16.7 psi(1,15 bar) 24.0 psi(1,65 bar) 24.0 psi(1,65 bar) (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which Hydraulic Design section under the Design Criteria are stated. (b)The Minimum Flow requirement is based on minimum flow in GPM(LPM)from each sprinkler,The associated residual pressures- are calculated using the nominal K-factor.Refer to"Hydraulic Design"in the Design Criteria section for details. TABLE A SERIES LFiI RESIDENTIAL FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA WET PIPE SYSTEMS • Body Cup Assembly: Design For systems designed to NFPA 13, the Y Brass ___ - _ _number of design s. lklers_is_to_be____ . _ _Cap: .. ."..-.::-:.--.-:�:.-Bronze-=_ - - -. - ---- - - Saddle -the four most hydraulically--demanding--- - - - Brass r�ter�a sprinklers.The minimum required dis- Sealing Assembly Beryllium The TYCO RAPID RESPONSE Series charge from each of the four sprinklers Nickel w/Teflon' LFII Residential Flat-Plate Concealed is to be the greater of the following: Soldered Link Halves Nickel Pendent Sprinklers (TY2524) are UL Lever Bronze •flow rates given in Table A for NFPA Compression Screw Brnze and C-UL Listed for installation in ac- 13D and 13R as a function of tern- Deflector cordance with the following criteria. perature rating and the maximum al- Brose Guide Pin Housing Bronze towable coverage area Guide Pins Bronze NOTICE • minimum discharge of 0.1 GPM/ Support Cup Steel When conditions exist that are outside sq. ft. over the "design area" corn- the scope of the provided criteria, re- prised of the four most hydraulically fer to the Residential Sprinkler Design demanding sprinklers for actual cov- Operation Guide TFP490 for the manufacturer's erage areas protected by the four recommendations that may be accept- sprinklers When exposed to heat from a fire,the able to the Authority Having Jurisdiction. Cover Plate,which is normally soldered The Series LFII Residential Flat Plate Obstruction To Water Distribution to the Retainer at three points,falls away Concealed Pendent Sprinklers must Locate sprinklers in accordance with the to expose the Sprinkler/Support Cup As- obstruction rules of NFPA for residential to expose At this point,the Deflector,sup- not be used in applications where the p air pressure above the ceiling is greater sprinklers as well as obstruction criteria ported by the Guide Pins, drops down than that below. Down drafts through described within TYCO technical data to its operated position. sheet TFP490. the Support Cup can delay sprinkler op The Solder Link Element of the Sprinkler/ eration in a fire situation. Operational Sensitivity Support Cup Assembly is comprised of two link halves that are soldered togeth- System Type Install sprinklers relative to the ceiling er with a thin layer of solder. When the Only wet pipe systems may be utilized, mounting surface as shown in Figure 3. rated temperature is reached, the sot- Sprinkler Spacing Hydraulic Design der melts and the two link halves se a- p Table A provides the minimum required The minimum spacing between sprin- rate, allowing the sprinkler to activate klers is 8 feet(2,4 m). and flow water. sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R as a function The maximum spacing between sprin- of temperature rating and the maximum klers cannot exceed the length of the allowable coverage areas.The sprinkler coverage area(Table A)being hydrau- flow rate is the minimum required dis- lically calculated;for example, a maxi- charge from each of the total number of mum of 12 feet for a 12 ft.x 12 ft. cov- 1 Registered trademark of Dupont "design sprinklers"as specified in NFPA erage area or 20 feet for a 20 ft. x 20 ft. 13D or NFPA 13R. coverage area. TFP443 Page 3 of 6 BODY , V SEALING (1/2"NPT) , / ASSEMBLY CAP ' ' ��j=•///%�1'`_�1 SPRINKLER � 111144.=.4,'� lj WRENCHING SADDLE 1 ;:��`` = SUPPORT 1 ; I AREA r ■Ii ,I� ; COMPRESSION CUP WITH 1 SCREW ROLL FORMED / THREADS It)��'I It_ LEVER WRENCH Lt, „ � RECESS GUIDE I '�_�' PIN ,.._.,-.�■..�.......��., f 1 SOLDER LINK � d • I I ELEMENT %Ilikid i GUIDE PIN i HOUSING i i I __ DEFLECTOR , --\J L I (OPERATED PUSH WRENCH DEFLECTOR ' r z----r---_i-i � POSITION) IN TO ENSURE I SPRINKLER/SUPPORT CUP I ENGAGEMENT ASSEMBLY WITH SPRINKLER 1 I WRENCHING AREA THREAD INTO RETAINER SUPPORT CUP 1 i WITH THREAD " UNTIL MOUNTING J • I DIMPLES FIGURE2 SURFACE IS c CD O 1 W-TYPE 78 FLUSH WITH ) EJECTION SPRINKLER WRENCH - --CEI LING----- --- -- ---- – – — —- SPRING SOLDER COVER PLATE/RETAINER COVER TAB ASSEMBLY PLATE • FIGURE 1 FLAT-PLATE CONCEALED PENDENT SPRINKLER(TY2524) ASSEMBLY 2-1/2'DIA. SPRINKLER- (63,5 mm) 1/2'(12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER ASSEMBLY NPT ADJUSTMENT FITTING / OPERATED -��1_ � SPRINKLER --,_imm.....h. _ • a� 1-718'11/8' PLATE���V (47,6 mm �� � ----,...../■_•,............_ , EINE L____� = t :rm 1/8"GAP 13,2 mm) RETAINER r 1_ ��� COVER- SPRINKLER- I 7/8'(22,2 mm) I I 3/16" RETAINER SUPPORT CUP SURFACE MOUNTING 1-1/8°(28,6 mm) • �. ASSEMBLY ASSEMBLY (4,8 mm) 1 -'-� . .-LW - " 3-3/16'DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 PROTECTIVE CAP AND ACTIVATED DEFLECTOR INSTALLATION DIMENSIONS TFP443 Page 4 of 6 installation 6. Screw on the Cover Plate/Retainer Replace sprinklers that: Assembly until its flange contacts The TYCO RAPID RESPONSE Series the ceiling. • were damaged by dropping,striking, LFII Residential Flat Plate Concealed Do not continue to screw on the wrench twisting, wrench slippage, or Pendent Sprinklers must be installed Cover Plate/Retainer Assembly such the like. in accordance with the following that it lifts a ceiling panel out of its • were modified or over-heated. instructions. normal position. • are leaking or exhibiting visible signs NOTICE If the Cover Plate/Retainer Assembly of corrosion. cannot be engaged with the Mounting Responsibility lies with owners for the Damage to the Solder Link Element dur- Cup or the Cover Plate/Retainer As- inspection,testing,and maintenance of ing installation can be avoided by han- sembly cannot be engaged sufficiently their fire protection system and devices dling the sprinkler by the Support Cup to contact the ceiling,the Sprinkler in compliance with this document, as only;that is, do not apply pressure to the Fitting must be repositioned. well as with the applicable standards of Solder Link Element(Figure 1). the National Fire Protection Association Obtain a leak-tight 1/2 Inch NPT sprinkler Care and (for example, NFPA 25), in addition to joint by applying a minimum-to-maxi- the standards of any other authorities mum torque of 7 to.14 ft.-lbs. (9,5 to 19,0 Maintenance having jurisdiction.Contact the install- Nm).Higher levels of torque can distort ing contractor or sprinkler manufacturer the sprinkler inlet with consequent leak- The TYCO RAPID RESPONSE Series regarding any questions. age or impairment of the sprinkler. LFII Residential Flat-Plate Concealed Automatic sprinkler systems are rec- Do not ahem ensate for i t to cam n Pendent Sprinkler (TY2524) must be p p maintained and serviced in accordance o and maintained to be inspected, tested, sufficient adjustment in the Cover Plate/ and maintained by a qualified - Retainer Assembly by under-or over- with the following instructions, tion Service in accordance with th local tightening the sprinkler. Re-adjust the requirements and/or national codes. position of the sprinkler fitting to suit. NOTICE 1. Install pendent sprinklers in the Before closing a fire protection system pendent position, with the center- main control valve for maintenance work line of the sprinkler perpendicular on the fire protection system that it can- to the mounting surface. trols,obtain permission to shut down the affected fire protection system from the 2. Remove the Protective Cap. proper authorities and notifyali person- 3. With pipe-thread sealant applied nel who may be affected by this action. ___ ___-__ _ _ -_ta_the_pipe_threads, and_using the____When_properly-installed,there-is-a-nomi- _--------- .-- - __-. — --__ _ _ W-Type 18 Wrench shown in Figure naI 1/8 inch(3,2 mm)air gap between - -- - -. - — `2, install and tighten the Sprinkler/ the lip of the Cover Plate and the ceil- Support Cup Assembly into the fit- ing,as shown in Figure 3.This alr gap ting. The W-Type 18 Wrench ac- is necessary for proper operation of the cepts a 1/2 inch ratchet drive. sprinkler by allowing heat flow from a 4. Replace the Protective Cap by fire to pass below and above the Cover pushing it upwards until it bottoms Plate to help assure appropriate release out against the Support Cup. The of the Cover Plate in a fire situation.If the Protective Cap helps prevent dam- ceiling needs repainting after sprinkler age to the Deflector and Guide installation, exercise care to ensure that Pins during ceiling installation and/ the new paint does NOT seal off any of or during application of the finish the air gap. Failure to do so may impair coating of the ceiling. sprinkler operation. Absence of a Cover Plate can delay the NOTICE sprinkler operation in a fire situation. As long as the protective Cap re- Do not pull the Cover Plate relative to mains in place, the system is con- the Enclosure.Separation may result. sidered"Out Of Service': Exercise care to avoid damage to sprin- 5. After the ceiling has been com- 'klers before, during,and after installa- pleted with the 2-1/2 inch (63 mm) tion.Never paint, plate, coat, or other- diameter clearance hole and in wise alter automatic sprinklers after they preparation for installing the Cover leave the factory. Plate/Retainer Assembly, remove Never repaint factory-painted Cover and discard the Protective Cap, Plates.When necessary, replace cover and verify that the Deflector moves plates with factory-painted units. Non- up and down freely. factory applied paint can adversely de- If the Sprinkler has been damaged lay or prevent sprinkler operation in the and the Deflector does not move up event of a fire. and down freely, replace the entire Sprinkler assembly.Do not attempt to modify or repair a damaged sprinkler. • TFP443 Page 5 of 6 • Limited Ordering Warranty Procedure Products manufactured by Tyco Fire Contact your local distributor for avail- Suppression & Building Products ability. When placing an order, indicate (TFSBP)are warranted solely to the orig- the full product description and Part inal Buyer for ten(10)years against de- Number(P/N). fects in material and workmanship when paid for and properly installed and main- Sprinkler/Support Cup Assembly tained under normal use and service. Specify: Series LFII Residential Flat- This warranty will expire ten (10)years Plate Concealed Pendent Sprinkler from date of shipment by TFSBP. No (TY2524), K=4.9,without Cover Plate/ warranty is given for products or com Retainer Assembly, P/N 51-114-1-160. ponents manufactured by companies Cover Plate/Retainer Assembly not affiliated by ownership with TFSBP Specify: Cover Plate/Retainer Assem- or for products and components which bly with finish (below) for the Series have been subject to misuse, improper LFII Residential Flat-Plate Concealed installation,corrosion,or which have not Pendent Sprinkler(TY2524),K=4.9, P/N been installed, maintained, modified or (below): repaired in accordance with applicable Standards of the National Fire Protection Chrome P/N 56-201-9-135 Association,and/or the standards of any Custom P/N 56-201-X-135 other Authorities Having Jurisdiction. Off White Materials found by TFSBP to be defec- P/N 56-201-0-135 five shall be either repaired or replaced, Pure White* at TFSBP's sole option.TFSBP neither (RAL 9010) P/N 56-201-3-135 assumes, nor authorizes any person to Signal white- assume for it, any other obligation in (RAL 9003) P/N 56-201-4-135 connection with the sale of products or Standard White(Grey White) parts of products.TFSBP shall not be (RAL9002) P/N 56-201-5-135 responsible for sprinkler system design errors or inaccurate or incomplete in- • Eastern Hemisphere sales only. formation supplied by Buyer or Buyer's `• Previously known as Bright White. representatives. Note: All Custom Cover Plates are _ ' painted=using Sherwin Williams Interior— - - -In no event shall TFSBP be liable,in con- Latex Paint. Contact TYCO Customer • tract,tort,strict liability or under any oth- Service with any questions related to er legal theory,for incidental, indirect, custom orders. special or consequential damages,in- cluding but not limited to labor charg- Sprinkler Wrench • es, regardless of whether TFSBP was Specify W-Type 18 Sprinkler Wrench, informed about the possibility of such P/N 56-000-1-265. damages,and in no event shall TFSBP's liability exceed an amount equal to the • sales price. The foregoing warranty is made in lieu of any and all other warranties. express or implied,including warranties of mer- - chantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on fail- ure of or defect in products,materials or components, whether the claim is made in contract,tort,strict liability or any oth- er legal theory. This warranty will apply to the full extent permitted by law.The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. • • tqCCII Flow I Tyco Fire Control Products 1-:-7:-.7:-'912-26-,,21;ZArr-r-orAPILC.AP'3/4-.!-:■,.. . . - BlazeMaster FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET TYCO FIRE PRODUCTS 451 North Cannon Avenue - Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TEL (800) 381-9312 • FAX: (800) 791-5500 E-MAIL techserv@tycofp.com I ,1,,,,I=e-ror:ii-caE.F.-...: f :1.-, ,,:ti•-:g 14, ;.;L, Iv a 1I ., .. -. . No. 19-1.5 TD915 4-1.1.20 9/2001 • Introduction Tyco Fire Products (TFP) BlazeMaster('CPVC pipe and the same time, they provide superior heat resistance and fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems. They are made from a materials used in the plumbing trade. Various adapters are specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping. All female post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability. the art additives. TFP BlazeMaster'CPVC products are Grooved adapters connect directly to grooved end valves easier to install than traditional steel pipe systems, and at and metallic pipe, with flexible grooved end couplings. Technical Data Sizes: 3/+"-3" Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See current TFP BlazeMaster Installation Instructions and ASTM F439 (Sch. 80) Technical Manual,for exact listing/approval information Color: Orange Pipe Nom.Pipe Size Avg. 0.0.Inches Avg. I.O. Inches Wt. Lbs./Ft. Wt.H2O filled Pipe Lbs./Ft. Ft. of Pipe per Lift Wt.per Lift Lbs. 3/+" 1.050 0.874 0.17 0.43 7875 1413 1" 1.315 1.101 0.26 0.67 5040 1320 1'/+" 1.660 1.394 0.42 1.07 2835 1191 1'/2" 1.900 1.598 0.55 1.40 2205 1136 2" 2.375 2.003 0.86 2.20 1260 1063 2 1/2" 2.875 2.423 . 1.26 3.22 1215 1531 3" 3.500 2.952 1.87 4.79 720 1344 • Fittings T,° T/O' T/o mil 45° Elbow _. �� T>o Reducing 2F 90° Elbow ► - - r� -_-_ _�� - _-_ _ -._______-___ _ __ _._._ 90 EIboW--- -BP - Tio' . u., , iI i • Part No. Size Sch. T/0 Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80050 '/+" Size Sch. 40 /" 0.08Ib. No. 1 2 Ib. 80025 '/" 40 °/,6" 0.09Ib. 80051 1" 40 3/e" 0.11 lb. 80032 1"X'/�" 40 "/,e" '3/le" 0.16 80026 1" 40 '/ 0.14 lb. 80052 1'/+" 40 3/+" 0.20 lb. 80027 1'/4" 40 '/e" 0.21 lb. 80053 1'h" 80 '/,a" 0.31 lb. 80028 1'/2" 80 1'/,e" 0.40 lb. 80054 2" 80 '/." 0.56 lb. 80029 2" 80 1'/+" 0.79 lb. 80055 2'/z" 80 '/." 0.89 lb. 80030 2'/2" 80 1'/2" 1.14 lb. 80056 3" 80 1" 1.19 lb. 80031 3" 80 113/16" 1.82 lb. I i I I T/O' a i , I/O 1 I ! Tee ■Ir T/° Reducing •_ Cross I 7 Cross IIIIIWIII p T/o I I I T/o T/0 I T/o sII T/O' 7/o' I/O T/O Part No. Size Sch. T5/O Wt. Part T/0 Wt. Part No. Size Sch. T/O Wt. 80000 '/l" 40 5/6" 0.11 Ib. No. Size Sch. 1 2 lb. 80009 3/." 40 '/.e" 0.13 lb. 80001 1" 40 '/." 0.19 Ib. 80015 1"X'/+" 40 "/,e" I "/,e" 0.28 80010 1" 40 15/,6" 0.23 lb. 80002 V/." 40 '/e" 0.26 lb. 80011 1'/+" 40 5/,6" 0.34 lb. 80003 172" 80 1" 0.51 lb. 80012 1'/z" 80 1'/16" 0.67 lb. 80004 2" 80 13/6" 0.90 lb. 80013 2" 80 1'/e" 1.00 lb. 80005 2'/2" 80 19/,6" 1.59 lb. 80014 272" 80 1'/,a" 1.91 lb. 80006 3" 80 1"/,6" 2.41 lb. 80008 3" 80 1'3/.3" 2.89 lb. • Ida° • Ir_T/O T/O -{ T/O Coupling _ _._ __ _. Cap _ Reducer _. 11i Bushing I Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. 80200 1"x'/4" 40 7/,6" 0.04 lb. 80075 '/" 40 /e" 0.07 Ib. 80100 '/." 40 5/,6" 0.04 Ib. 80201 1'/+"x'/+" 40 '/6" 0.11 Ib. 80076 1" 40 '/6" 0.11 lb. 80101 1" 40 3/e" 0.06 lb. 80202 1'4"x 1" 40 5/16" 0.12 lb. 80077 11/4" 40 3/45" 0.12 lb. 80102 1'/4" 40 '/2" 0.10 lb. 80203 1'/2"x'/1' 80 5/e" 0.16 lb. 80078 11/2" 80 3/16" 0.25 lb. 80103 1'/2" 80 5/e" 0.20 lb. 80204 1'/2"x 1" 80 1/2" 0.14 lb. 80079 2" 80 '/16" 0.38 lb. 80104 2" 80 5/6" 0.31 lb. 80205 11/4"x 114" 80 3/6" 0.17 lb. 80080 2'/2" 80 3/16" 0.67 lb. 80105 21/2" 80 7/e" 0.58 lb. 80206 2" x'/." 80 1/4" 0.27 lb. 80081 3" 80 3/16" 0.91 lb. 80106 3" 80 1" 0.88 lb. 80207 2" x 1" 80 "/16" 0.26 lb. 80208 2"x 11/4" 80 9/,6" 0.24 lb. f T/O 80209 2"x 11/4" 80 7,6" 0.19 lb. Grooved I • 80215 2'/2"x 1" 80 1'3/46" 0.42 lb. Coupling Poe O.D. 80214 2'/2"x 1'/4" 80 13/4" 0.45 lb. Adapter _ 1111111_1_1 80213 2'2" '2" 5 6"p / x 1 / 80 1 / 0.46 lb. 80211 2'/2"x 2" 80 191,6" 0.29 lb. Part No. Size Sch. T/O Wt. Pipe OD 80210 3"x 2" 80 2 3/,6" 0.72 lb. 80160 174"x 1'/4" Grooved 40 2 5/+6" 0.78 lb. 1'/4"(1.660") 80212 3"x 2'/:" 80 1 t5/+6" 0.47 lb. 80161 11/2"X 1'/z" Grooved 80 2 5/+6" 0.95 lb. 172"(1.900") 80162 2"x 2" Grooved 80 2 5/16" 1.42 lb. 2" (2.375") 80163 2'/2"x 2'/2" Grooved 80 2 5/16" 2.28 lb. 2'/2"(2.875") ��--- 80164 3"x 3" Grooved 80 2'/4" (3.500") Reducing Tro'3.00 Ib. 3" (3.500') 9 � 7 80168 3"x 76.1 mm Grooved 80 2'/4" 2.72 Ib. 76.1 mm (3.000") Tee T.Q T/0' •• T0" ._ ===_ -- ---- --- i - -Part_�_= lb..;----_-_ � No. Size Sch. 1 2 3 Ib. Female ��111 80132 3/4"X 3/4"x 1" 40 3/4" 3/4" 5/e" 0.14 Adapter 80133 1"X 3/4"X'/4' 40 1/2" "/+e" 3/4" 0.14 80134 1"X 3/4"X 1" 40 5/e" 3/4" 3/4" 0.17 Part No. Size Sch. I/O Wt. 80260 1"x 1"X 3/," 40 '/." '/." "/+e" 0.16 80142 3/<"x 3/4"NPT 40 5/e" 0.41 lb. 80135 1'/4"x 1"x 3/<" 40 '/+6" 3/<" 'S/,6" 0.21 80145 1"x 1" NPT 40 3/4" 0.63 lb. 80136 1'/4"X 1"X 1" 40 "/1e" 3/<" 15/,e" 0.22 80146 174"x 11/4" NPT 40 7/e" 1.03 lb. 80137 1'/+"X 1"X 1'/<" 40 13/,6" 15/1e" "/1e" 0.26 80147 11/2"X 1 72" NPT 80 1" 1.42 lb. 80261 174"X 1'/4"X 3/4" 40 5/e". 5/e" '/e" 0.23 80148 2"x 2" NPT 80 1'/e" 2.66 lb. 80262 1'/4"X 174"x 1" 40 3/4" 3/4" 7/6" 0.26 80138 174"X 13/4"x 172" 80 1" 1" 1" 0.43 rio 80140 1'/2"x 174"X 3/4" 80 '/2" 5/6" 1" 0.36 80141 1'/2"X 1'/4"x 1" 80 '/2" 5/e" 1'/e" 0.38 Male __ _ __ - 80263 1'/2"x 1'/2"x 3/4" 80 9/,e" 9/19" 1" 0.36 Adapter 80264 1'/2"X 1'/2"x 1" 80 3/48"/18" 1" 0.38 80275 1'/2"X 1'/2"x 174" 80 7/e" 7/e" 1" 0.45 Part No. Size 1 Sch. T/O I Wt. 80265 2"x 2"x'/+" 80 3/4" 3/<" 1'/6" 0.61 80157 '/<" x'/4" NPT 40 15/,6" 0.33 lb. 80266 2"x 2"x 1" 80 '/e" 7/6" 1'/e" 0.66 80158 1"x 1" N PT 40 1'/e" 0.56 lb. 80274 2"x 2"x 1'/4" 80 1" 1" 13/6" 0.74 80267 2"x 2"x 1'/2" 80 11/9" 1'/e" 1'/e" 0.78 Ir.T/0 80271 21/2"x 2'/2"x 1" 80 11714" 1"/1a"" 19/,6" 1.43 80272 2'/2" X 21/2"X 174" 80 1"/,a" 1"/,e" .19/+6" 1.46 Reducing __-- ___ 80273 2'/2"x 2'/2"x 1'12" 80 1"/1e" 1"/,6" 19/+e" 1.48 Coupling 80276 2'/2"X 2'/2"X 2" 80 1"/16" 1"/i6" 191,6" 1.50 ,/--- 80270 3" x 3" x 11/2" 80 13/4" 13/4" 113/16" 2.28 Part No. Size Sch. T/O Wt. I 80268 3"x 3"x 2" 80 13/4" 13/4" 1314" 2.25 80220 1" x '/4" 40 '/6" 0.08 lb. 80269 3"x 3"x 2'/2" 80 13/4" 13/4" 115/,6" 2.44 M T/O T/O Sprinkler Head Adapter �x"_ Sprinkler Head Adapter ' _ • with Brass Threaded Insert —11• with Brass Threaded Insert Part No. Size Sch. T/0 Wt. Part No. Size 1 Sch. TIC I Wt. • 80175E '/4"x'/2" NPT 80 7/,e" 0.20 lb. 80175W 1/4"x 1/2" NPT 40 '/,e" 0.19 lb. 80176E 1"x 1/2" NPT 80 7/,s" 0.22 lb. 80176W 1"x '/2" NPT 40 '/,e" 0.18 lb. 80177WL 3/4'x 1/2" NPT 40 9/16" 0.16 lb. 80179 1 x 3/4" NPT 40 3/4" 0.43 lb. T/o' ; eraii.• qtr Back-to-Back Cross _. sr Liu �I ._Sprinkler Head Adapter .�.- a;,�, with Brass Threaded Insert — °="- (Spigot) --- __ T/°' with Brass Threaded Insert f Tro' I/O' Part No. Size Sch. T/O I Wt. Part T/O Wt. 80177L 3/4"x 1/2" NPT 40 '/2" 0.16 lb. No. Size Sch. 1 2 lb. 80178 1"x112" NPT 40 '/2" 0.20 lb. 80462 1"x 1"x'/2"NPT x 1/2"NPT 40 1/4" 11/s" 0.46 80463 1"x 1"x '/2"NPT x 1/2"NPT 40 5/8" 15/-s" 0.47 T/0' Sprinkler Head Adapter III ro 1 90° Elbow IlltiMilt,� .with Brass Threaded Insert - T'O' Back—to-Back Tee Tro' ��Q Q — • with Brass Threaded Insert 1 ."-Pr; .>-,-^r∎ I Tro' Tro' Part T/O Wt. Part Size Sch. T/O Wt. if Size Sch. No. - -- 1 2 -1b. _ - - —No. — -- - --_ .-1__ .�.2 - Ib.- , 80199 3/4"x '/2" NPT 40 3/4" ,5/,e" 0.20 80459 1"x '/2"NPT x '/2"NPT 40 "/te" 15/10" 0.48 80189 1"x '/2" NPT 40 13/,6" 1'/,s" 0.26 80460 1"x '/2" NPT x '/_"NPT 40 "/,s" 1'4" 0.46 Part Size Sc .h 1 20 3 Wt. 80250 3/4"x 3/4"x1/2"NPT 40 5/3" 5/e" 1" 0.22 ' 80251 1"x 1"x'/2"NPT 40 "/,e" "he" 13/,6" 0.29 gilt Tfc! 80249 1"�x 1"x 1"NPT 40 15/1e" 'she" 1'/,e" 0.73 Sprinkler Head Adapter 80256 174"x in x /2 NPT 40 7/,6" 5/t6" 1'/6" 0.30 Tee i '-"��-- 80252 11/4" x 11/4"x '/2"NPT 40 7/16" 7/,8" 1'/e" 0.31 with Brass Threaded Insert ' 80257 1'/z" x 11/4"x '/z"NPT 80 9/,6" 5/e" 1'/1e" 0.43 Tro' _1_ T/o' 80254 11/2" x 11/2"x '/2" NPT 80 9/,6" 9/,6" 17/16" 0.46 80258 2"x 11/2"x'/2"NPT 80 1/2" 5/•" 15/s" 0.56 80253 2" x 2"x'/2"NPT 80 1/2" '/2" 1'/8" 0.62 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten(10)years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten(10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse,improper installation,corrosion,or which have not been installed,maintained,modified or repaired in accordance with applicable Standards of the National Fire Protection Association(NFPA),and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced.at Tyco Fire Products sole option. Tyco Fire Products neither assumes,nor authorizes any person to assume for it,any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or • incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE.IN CONTRACT,TORT,STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY.FOR INCIDENTAL,INDIRECT.SPECIAL OR CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT LIMITED TO LABOR CHARGES,REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED,INCLUDING `- WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, tYICO/Flow Control/Tyco Fire Products 0 Dynan!Thread Full Line Soh-40 Replacement Dyna-Thread• offors the life expectancy of Sch4O with superior hydraulics and Beater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkle:pipe industry.It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 .-Coiiiparisarr :ta Lit Pipes'. • Dy a-Thread's inside diameter is up • with its inueased gtrength and lighter • Marc wall thickness at the thread to 3.6%larger than Soh-40 giving it weight,Dyna-Thread reduces (CRR=1-00)gives Dyna-Thread superior hydraulics.And,when used installation fatigue and is ideal for better life expectancy than lightwall in oembination with Dyna-Flow pipe, retro-fit applications. threadablc pipe joints. down sizing often occurs, Corrosion Resistance Ratio (CRR)is a • Unlike lightwall threadable pipe, • Dyne-Thread is fully listed and UL(Underwriters Laboratory)term for Dyna-Thread has no thread gauge approved by UL,U'LC,and FM for the estimated life expectancy of a pipe warning, fire sprinkler applications. joint.This is based on the calculated •• The life expectancy of Dyne-Thread wall thickness at the base of the first D'na Thread is approved for and Sch-40 arc equal based on the exposed thread,assumed to be the standard hanger speng(15 fi Dyne- calculated wall thicknesses per UL. weakest point of the pipe length. Dyne O.C,),can be used as earthquake sway bracing, is safe to use as Thread and soh-40 have the same • The consistent quality of steel used to calculated wall thicknesses at this point dry' make Dyna-Thread faouitates smooth and are bath assigned the same CRR of . Dyna-Thread is safer to weld on, threading and lower maintenance 1,00. •costs, Dyne-Thread is more widely The internal slur.:.ce of all black Allied accepted than lightwall threadable • The exterior of Dyne-Thread is where Svh-40 is specified. protected by a clean,durable mill Tube&Conduit Fire Sprinkler pipe coating for extended shelf life and products up to 4.5000"in&erecter is easy paint application. coated with our new Antibacterial Formula,"ABIn',In scientific laboratory - test,ABS proved to have superior Specifications $ ! rovIs. resistance to microbial colonization of GO pipe walls,thereby delaying or possibly Super 40/Dyne-Thread pipe is �7 preventing the onset of manufactured to meet:AS'IllA-135, Listed Approved Listed Microbiologi❑ally Influenced corrosion Grade A and is in compliance with (MIC)when the First Sprinkler System ing 1VFPA-13.All sizes of Super 40/Dyna- is first installed. Thread are rated at 300 psi work pressure.Super 40/Dyna-Thread is UL Specifications - •• and ULC Listed for wet,dry deluge and pre-action sprinkler systems and FM NI'S Namleai 1,0, WI, Wt,(1320 Filled) Pas/ WVLIPI(21') W1/1.111(24') WVLIft(25' Approved for use in wet systems.Super In;mm In;mm Lba'Ft,K/vm Lbs Ft,•Kg/m Lift Lbe,Kg Lbs;Kg Lim;Kg 40/Dyne-Thrcad can be`hot-dip" I° 1,080 1.330 1,75 70 1955 2234 2327 galvanized to moot FM requirement for 25 274 2.0 2.80 70 887 7073 705. dry systems, Super 40/Dyna-Thread is 11/e" 1,408 1,870 2.54 51 2002 2285 2984 approved for all threaded couplings and 32 55.8 2.8 3,78 51 908 7038 ice welded outlets and is suitable for all 1 ii' 1.699 2.290 3.22 44 2115 2 419 251. roll-grooved,and plain-end fittings. 90 41.6 3.4 4,79 44 959 7097 114• (See listing inform anon). 2" 2.104 3.050 4.57 30 1921 2196 2287 .50 53.4 4.5 880 30 877 996 103 telCal flow control gibe�J t 16100 S.rcLathrop •• Harvey, IL 50428 Customer Service:e: (• 11350 Noom Rd.••Philadelphia,PA 19154 (800)882-5543 tusg a oONOUir 2525 N,27th Ave,•Phoenix,AZ 85009 Fax 708-339-1808 S3-3 . Submittal Data Sheet - Dyna-Threade Sump Hers Full Line Sch-40 Replacement Dyna-Th end aprinkleapipe reptr m:us an rngiaecrj advancement for the sprinkle: pipe industry.It combines the safety and longevity of traditional Soh-40 pin:with quality and srgatYior hydraulic advantages, Comparison to Schedule 40 Dyna-Thready inside chain=is up to 3.6%large than Sch-4-0 a-ving it sap 'ior hydraulics,Also,wh=used in combination with Dyne,-Flow pipe, dawn siring oft occurs.Dyne-'Thread is fully lifted and approved UL, ULC, ,--;i ':; �- -'t-.."7...• and FM for fire sprinkler applications.The life expectancy of Dyne-Tread and Sch-40 t' ::•.:::-:-.::. --' a_: A.:7---:---. are equal based on the calculated wall thicleacsscs per UL,The consistent quality of ="' is....'... '- :- :_._ steal used to make Dyna-Tbreed factlirarea smooth threading and lower maintanane costs.The exterior of a-Thread is _ 1 't"•`: •-•-• I'}yn protected by a cicea,durable milt coating far ��:�� �'�, _• cxteaded shelf life and easy paint application.With its increased strength and l + . ,. '•-' ' t- ' .Y' : . weight Dyne-Thread reduces installation fatigue and is ideal for retro-fit applications. ° • C. -a.". a= �-. Corrosion Resistance a UL 4`:'• •.'r . t e: v' Ra.io(CRP)is (Uadenwritots Lahozatozy)term for the � �'•�`=�` ..,#?...- =" � "!"- estimated life peetann,of a pipe.j _ted wall thickness i .' ;'. � < Dirt.This is loaned�the r�)rmi„ �gy ;~.1 iA',•�-'�:-':- :1• r"• t'�r�. ti at the base f the firs ': - - i' ia.•9: e o t exposed har=d,easumcd to be the weakest paint of the pip: ''>r. P '`.; . r r-:=rt• t length.Dyne-Thread and Soh-40 have the same calculated well thick ceases at thus Y :` •4-;>. . '' r s °`:i `{ :0 Dint and are both assigned 1 point the same CRR of I.00. `:."�•;Y���,r• `���'��' �.� -')`t�� -# z � � ':ace Comparison to L.W.T.Pipe More wall thick noit at the thread(CRR=1.00)gives :: i' .:-.-.,.143 ,-,,y Dyne-Thread better life expectancy than li '' 4 •' P 'Y Bhtuxll threadebL;pipe joinry. Gnlr1-r� ., • •._x���. -; „'.,. � ;;,H light-wall threadablc pipe Dyna-Thread has no thread gauge warning.Dyes-Thread is rfi't ` `,' �: `. approved for standard hanger spacing(15 ft.0.C.),can be used as earthquake sway �°1� ` t* a -: bracing,•and is safe to lice as drops.Dyna-Tbread is safer to weld on than marry zinc- ' '" ` : : .i coated li . at }tii::�::^:ae,-- ghtwall threadable pipe products.Dyna.Thread is more widely accepted the } t `�' ...,, . .st.,"''•'":" i : :t •�it liglitwall threadable where Seh-40 is specified, , ' Specifications&Approvals Super 40/ Dyna-Thread pipe is manufactured.to Specifications meet:ASTM A 135,Grade A and is in NPS Nomloal I.Q. WI. Wt.(H2U Filled) Per/ wilt(21') WV1ilt(24') %Mt(25') compliance with NFPA-13.All sizes of Lit;mm fit mm LbrIft Kahrl Lta Fl Kgiht L17t Lam;Kg Lbs;Kg Lbt;Kg Sups 40/Dyna-Thread are rated at 300 1' 1.080 1.330 1.75 70 1855 2234 2327 psi working pressure. Super 40/Dyne- 25 27.4 2,0 250 70 887 1079 1056' and pro-action dLrsted and 1Yi 1,408 1.870 - 2.54 51 2002 2283 2384, ipr- l systems 97 36.8 2.8 3.78 51 908 1035 1081 FM Approved for use in wet systems. Super 40/Dyna-Thread can be"hot-dip" 1W 1.839 2290 3.22 44 2115 2418 2515 galvanized to meet FM requirement for 40 41.6 3,4 4.79 44 959 1097 114,1 dry systems. Super 40/Dyne-Thread is 2' 2.104 3.050 4,67 30 1921 2196 2287 approved for all threaded couplings and 50 53.4 9,5 6.90 30 871 995 1032 welded outlets and is suitable for all roll- grooved,and plain-end fittings. (Soo Anshan Ttbc and Pipe was acquired by Allied Tube and Conduit on February 1, listing information), 1997.The engineered lightwall and tandard wall family of produots although they The internal surface of all black Fitt have different names arc the name in all respects with regard to strength,weight, ' Sprinkler pipe up to 4-5000"in diameter bundle coral,listings and approvals.For example, shall be coated with Allied Tube& Dyne-Flow and Super Flo arc the same product as 0 Conduit Antibacterial Formula"ADP", t a Thread Super 40.XL is manufactured with Exterior galvanized coating.BLT is Liatad Approved Utsted manufactured with Black taog=canting. Prnia;1; Sprinkter Cur tractor; Draw Eng,naor: Specification Reference: _cyet_ern Type: Locations: Comments: . S3-4 (9® vs Rap . porirmiER VANE TYPE WATERFLOW APPROVED SWITCH WITH RETARD Potter Electric Signal Company 2081 Craig Rd., / St. Louis, MO 63146 / (800)325-3936 / (314) 878-4321 SERVICE PRESSURE UP TO 450 PSI CHARACTERISTICS FOR 2" TO 8" PIPE SIZES 250 PSI FOR 10" PIPE SIZE U.L. LISTED AND F.M. APPROVED MINIMUM FLOW RATE FOR ALARM-10 GPM DIMENSIONS & WEIGHTS: See Fig. 2 ENCLOSURE: Cast Aluminum Finished: Red Enamel �`'T`"'� . CONTACT RATINGS: Two sets of S.P.D.T. (Form C) 15.00 Amp. @ 125/250V. AC 0.50 Amp. @ 125V. DC 0.25 Amp. @ 250V. DC 2.50 Amp. @ 0-30V. DC Resistive ENVIRONMENTAL LIMITATIONS: 40°F/120°F 4.5°C/49°C General Purpose for Indoor Use CAUTION:This device is not intended for applications outdoors or in explosive environments. ,0;0"" ° SIZES AVAILABLE: U.L. - For Schedule 40 Pipe: 2" thru 10" For Schedule 30 Pipe: 8" F.M.== For Schedule 40 Pipe:2" thru 6" For Schedule 30 Pipe: 8" and 10" ' u SERVICE USE Automatic Sprinkler NFPA-13 One or Two Family Dwelling NFPA-13D f'; Y Central Station NFPA-71 Local NFPA-72A Auxiliary NFPA-72B Remote Station NFPA-72C Proprietary NFPA-72D U.S. Pat. Nos. 3,912,247 OPTIONAL: Cover Tamper Switch 4,062,377 Order Stk. No. 5420220 The Model VSR-D is a vane type waterfiow switch for The flow condition must exist for a period of time necessary use on wet sprinkler systems. It is UL Listed for use on to overcome the selected retard period. steel pipe;schedule 40 sizes 2"thru 10"and schedule ENCLOSURE:The unit is enclosed in a general purpose, 30 size 8" and has FM approvals for schedule 40 steel pipe in sizes 2" thru 6" and schedule 30 pipe in sizes indoor use, cast aluminum housing. The cover is held in 8" and 10". place with two tamper resistant screws which require a see- cial key for removal.A field installable cover tamper switch The unit may also be used as a sectional waterflow is available as an option which may be used to indicate detector on large systems. unauthorized removal of the cover. See Bulletin 751 for installation instructions of this switch. The unit contains two single pole, double throw, snap RETARD ADJUSTMENT: The unit has an adjustable • action switches and an adjustable pneumatic retard. pneumatic retard to prevent false alarms due to water The switches are actuated when a flow of 10 gallons surges.The retard is adjustable from 0 to approximately 75 per minute or more occurs downstream of the device. seconds. 2-88 CAT.#A010 PAGE 1 . • -. , . __. VSRD° Potter Electric Signal Company 2081 Craig Rd., / P.O.Box 28480 / St. Louis, MO 63146 / FAX: 314 878 7264 VSR-D INSTALLATION FACTORY ADJUSTED FIG. 1 SENSITIVITY SPRING. DO NOT ADJUST RETARD ADJUSTMENT TO CHANGE TIME TURN KNOB (EITHER DIRECTIONI FOR ' DESIRED TIME DELAY. �jl TIGHTEN NUTS USE THE MINIMUM AMOUNT / TALTERNATELY A OF RETARD NECESSARY TO �� EVENTUAL PREVENT FALSE ALARMS. _6 50 Fr-LBS. A'B'SETTING IS USUALLY , OF TORQUE. ADEQUATE FOR THIS. MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW. �, ROLL PADDLE IN TO INSTALL, OPPOSITE DIRECTION • FOR 2"AND 2 V2"SIZES OF WATERFLOW. DRILL 11/4"HOLE. ' FOR ALL OTHER SIZES DRILL 2"HOLE o it 1� APPROX. RETARD SETTING ON SEC.) J 0 A B C D E 1 !I r 0 10-25 20-40 35-55 50-70 50-110 OPTIONAL: Order Tamper 5420 Order Stk. No.3420220 DIRECTION OF � - - - -- 4-1 _j -- - - _ _ . _ . - - - t.,_ • LOW DWG.5400710-305 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL CAUTION: AN UNINSULATED SECTION OF A SINGLE CONDUCTOR IS NOT PERMIT- TED TO BE LOOPED AROUND THE TERMINAL AND SERVE AS TWO — I SEPARATE CONNECTIONS.THE WIRE MUST BE SEVERED TO SERVE I —1N�pMING AS TWO SEPARATE CONNECTIONS,THEREBY PROVIDING SUPERVI- SION OF THE CONNECTION IN THE EVENT THAT THE WIRE BECOMES DISLODGED FROM UNDER TERMINAL. n iNG"-- DWG.5400710-31 oUT G INSTALLATION INSTRUCTIONS: These devices may Clean the inside of the pipe of all growth or other mate- be mounted in a horizontal or vertical pipe. On horizon- rial for a distance equal to the pipe diameter on either tal pipe they should be installed on the top side of the side of the hole. pipe where they will be accessible.The units should not Roll the vane so that it may be inserted into the hole;do be installed within 6 inches of a fitting which changes the not bend or crease it. Insert the vane so that the arrow direction of the waterflow or within 24 inches of a valve on the saddle points in the direction of the waterflow. or drain. Install the saddle strap and tighten nuts alternately to an Drain the system and drill a hole in the pipe using a cir- eventual 50 FT-LBS. of torque. See Fig. 1 above. cular saw in a slow speed drill.The 2"and 21/2"devices The vane must not rub the inside of the pipe or bind in require a 11/4" hole; all other sizes require a 2"hole. any way. TESTING The frequency of testing for the model VSR-D and its associated protective monitoring system should be in accordance with applicable NFPA Standards and/or the authority having jurisdiction,but under no circumstances less than bi-monthly. ..AT. #A010 PAGE 2 2-88 .:,• . TESTANDRAI R - I _ _ . • . . • .. .. r r v=a ^u.n , ,.ti 4 WIZEN YMe C; 4 app-1.. t"..1.y y r '11=.a} j f. �' b 'm 6t,; 77ki ' w,L„Y •...,ry ,rMF° ., — Y P 4 r,. 4 1 . f rb +k�Y�i o-S9Jedr” �,��,7,r,t5 ,) e 3 ,h -'-' nne�u'!1> 1�t' .- r 'w,,.�"c"L'.ri,"�,2"' ` -th�''",.,..�... 4,, 0,1gto''j 31. 't �d.u'''A. �' 5 S6'�'$ kuh c �t ;q' t 6 P S��� S r a ,,5 { ' ��p r r I J a WA gip,' c 1,t �y 1 P -'' 1 I 1 P t r 5 J 1� 3'Cdb'7!A'> ,.' `t r,� r, 1. +Tl '� �" 5+ 1 .� rt 7 F.stFFq.co..Sri t4 Film.td I �. 2E s� 1r r 4. 1 i it (� e�'�r F U.1:.?Most to.1.74 1 pia afe.!r P{t pl raten•�g .j:nY'4 `1 ..' '', tfi: �I�,� fj e � �'' 'fir t .r eb.-..' t r.Y ^ a r sfbE;' N1 _ .. .... - ---- Fir'!.{µ `'"d 4 t— 'ei '''.el ,'fir ' ti,,,' y.�. - eel 1t � Yo-fil3 L� Cr°'rk $ " Shy :p i !^1 Y frr -'4. 1 1-.b g ala 4'.' o-3 a 'c,G • The AGF Manufacturing Co., Inc. Model 1000 has been designed to provide both the Test Function and the Express Drain Function in a multi story installation. • Complies with all requirements of NFPA-13, and NFPA-13R • Complies with all requirements of NFPA-13D (HOUSING) • Positive Shut Off = Single Locking Handle • Tapped 1/2" for Pressure Gauge • Tamper Resistant Orifice permanently installed • • Available with all required Orifices __ • Orifice size noted on Indicator Plate • Lightweight and compact (11/4" weighs 5 lbs.) • 300 PSI Rating • Fused, tempered, tamper resistant Sight Glasses 4- 0 MODEL 1000 300 PSI _ TEsTANDRAIN 3/4 " * 1 11 1411 1/2 *'f."NOT FM APPROVED PLAN VIEW FRONT VIEW FROM BRANCH GAUGE OUTLET EN e - ■\/ / � \ PROVIDED el"< D �;°li TO DRAIN 1 Iii II _ OFF 1 i c a ' �t�III STREET EL 21111 isi FRONT VIEW/HORIZONTAL INSTALLATION. STREET EL TO DRAIN OR PIPE i III_ t i 0 111 TO DRAIN F 01111111 FOR RIGHT HAND/STRAIGHT INSTALLATION .Wommr ; ."( TO DRAIN n . l APPROVALS • UL and ULC Listed 0 • FM Approved except 3/4" • NYC BD. of SSA CAL. NO. 720-87-SM • CA. State Fire Marshall ORIFICE SIZE PROVIDED-3/E—7/16 1/2 1 7/32-5/B k*73/4* k DIMENSIONS—INCHES MATERIAL LIST SIZE A B C D E F G H PART MATERIAL 3/4 5'/is 13/a Z3/e 4'/e 33/a 13/a 49/6 65/16 HANDLE STEEL STEM ROD BRASS 1 5'/I6 13/4 23/a 4Y8 33/a 13/4 49/I6 65/i6 BALL C.P. BRONZE 1 'A 57/16 13/4 27/a 45/a 35/16 11S/16 5I/2 77/16 BODY BRONZE VALVE SEAT GLASS INPREGNATED TEFLON 1 '/2 67/16 13/4 3"/16 57/16 31/2 23/a 8'/16 107/16 INDICATOR PLATE STEEL 2 6'/16 13/a 3"/16 57/6 3'/z 23/a 81/6 i 0'/16 HANDLE LOCK SPRING STEEL SIGHT GLASS (2) FUSED TEMPERED GLASS ** Available on I'I. to 2"size units only. AGF MFG. CO. JOB NAME: (_ . Box 4437, 150 Mt. Bethel Rd. Warren, N.J. 07059-0437 ARCHITECT: MADE IN U.SA Telephone (908) 604-6471 ENGINEER: Fax (908) 604-6501 CONTRACTOR: 1000 8/94 . IOLCO INCORPORATED CORONA,CA (909)737-5599 0 c® Fig. 27 & 27A "Stand-Off" Hanger/Restrainer for CPVC Plastic Pipe Size Range–3/4" & 1" CPVC Plastic Pipe*. Material– Carbon Steel, Pre-Galvanized. Function–Designed to be used as a hanger/restrainer**for CPVC piping ''Nt,where the "stand-off'design will ease installation by eliminating the need for \\ ■ wood blocking. Features: / ': • Flared edge design protects CPVC from any rough or abrasive surfaces. ' • Snap-in retainers hold pipe firmly in place during installation. • The "Stand-Off'design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting Fig. 27 surface orientation. • Attaches easily to wood structure with 2 hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" sockets, o eliminating impact tool damage to pipe Approvals- Underwriters Laboratories Listed in the U.S. (UL) and Canada ' a t (cUL) to support automatic fire sprinkler systems. Meets and exceeds the irequirements of NFPA 13, 13R, and 13D. Fig. 27A **Important Note–When installed in slot opening on Fig,27, Fig, ---�� -provides additional sta-bility and satisfies the UL vertical restraint requirement where needed. \ I Order By–Fig. 27: By figure number and CPVC pipe size. \ Fig. 27A: By figure number and CPVC pipe size. i, U.S. and International Patent application in process. *for other sizes consult factory. Fig. 27 and Fig. 27/27A have also been tested by U.L. mounted on 3/8" composite wood web material (such as TJI Series/Trus Joist MacMillan) Fig. 27/Fig. 27A without the use of back up wood blocking. When using Fig.27 & 27A in Combination combination on 3/8"web to satisfy the UL requirement for vertical restraint, FIG.27 install 2 reinforcing speed nuts (Fig. 27B). Fig.27B is UL Listed only when WIFIG.27A used with Tolco products. ■_.', FIG.27B � FIG.27 i I-.]114 W/FIG.27A i i II 1 FIG.27 FIG.27 FIG.27 FIG.27 FIG.27 • I_I gr.= —.0 . . . . .. ILI- , _. ism.."..mmis (0 Typical Applications 01 • ES-A-2000B Series 2000E A M E S . Double Check Valve Assemblies FIRE&WATERWORKS'" Sizes: tfz" —2" (15-60mm) PLI/6"— .� ,, 1 Features• Ease of maintenance with only one cover 2"20008 HC • Top entry (50mm) • Replaceable seats and seat discs 5 • Modular construction ;,, 60 • Compact design • -'/z -2'-(15—50mm)Cast bronze ,-—'A' ) body construction �•2000B • Top mounted ball valve test cocks , ( � 20mm • ;Low pressure drop. • No special tools required Series 2000B Double Check Valve Assemblies shall be installed at referenced cross-con- • '/s"—1"(15—25 mm)have nections to prevent the backflow of polluted water into the potable water supply. Only tee handles those cross-connections identified by local inspection authorities as non-health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation,frequency of Available Models testing or other installation requirements. r Suffix: These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are B_..Quarter.turn ball valves _approved_bytheFoundation_for Cross=Connection_ControLand_Hydraulic Researchat>ihe • LBV- less ball valves -University of Southern Califorria. - - LH- locking handle ball valves(open position) Specifications SH- stainless steel ball valve handles A Double Check Valve Assembly shall be installed at each noted location.The assembly HC- 21/2"inlet/outlet fire hydrant fitting shall consist of two positive seating check modules with captured springs and rubber seat (2" valve) discs.The check module seats and seat discs shall be replaceable.Service of all internal Prefix: components shall be through a single access cover secured with stainless steel bolts.The U- union connections assembly shall also include two resilient seated isolation valves and four top mounted, re- silient seated test cocks.The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std.C510.Approved by the Foundation for Cross-Connection Control and Pressure — Temperature Hydraulic Research at the University of Southern California.Assembly shall be an Ames Temperature Range:33°F—140°F Company Series 2000B (5°C—60°C) Approvals Maximum Working Pressure: 175psi t ASSE, IAPMO,CSA,UPC (12 bars) • Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Standards • Model LBV is not listed. ASSE Std. 1015,AWWA Std. C510 u UL Classified(LBV models only)3/;—2°(19—50mm) ® ce r , IAPMO PS31, CSA B64.5 . Horizontal and vertical"flow up"approval on all sizes. 7 �1 P I\V't�o Job Name Contractor Job Location Approval Engineer Contractor's P.O.No. Approval Representative Ames product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.a m esfi rew at a r.c o m Dimensions - Weights 1. A J . • . r .� ki_ 1 �� C \� 111111Pi F H - - ► 41 G Suffix HC-Fire Hydrant Fittings dimension "A"=231/2"(594mm) Size(1)N) A B C FDimensions G H I Weight Model in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. 20008 1/2 15 10 254 4%6 117 2'/,s 62 5 127 3% 85 23/0 59 21/0 52 4.5 2 20008 M3 % 20 11'%6 282 4 102 3'%6 79 63/16 157 37/,s 87 2% 54 1%6 33 5 2.3 2000B 1 25 13'/ 337 5'/6 130 4 102 71/2 191 33/s 85 1"/6 43 11/6 43 12 5.4 20008 11 32 16% 416 5 127 35A6 84 91/2 241 5 127 3 76 2 50 15 6.8 20008 11/2 40 16% 425 4% 124 31/2 89 93/4 248 513/6 148 3'%6 79 211A6 68 15.86 7.2 20008 2 50 191/2 495 6% 159 4 102 13%6 340 6% 156 3,16 87 2i1A6 68 25.75 11.7 Strainer sold separately Capacities bars psi 11A"(32mm) As compiled from documented Foundation for Cross-Connection Control 1 14 and Hydraulic Research at the University of Southern California lab tests. in .8 12 "Typical maximum system flow rate(7.5 feet/sec.,2.3 meters/sec.) d .5 8 bars psi %"(15mm) * m .4 6 N .8 12 in .3 4 J .7 10 - _ a .1 2 �. • 3 .4 6 0 0 . 3 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm ; w rn 4 0 38 76 114 152 190 228 266 304 342 380 418 456 1pm ------ -i-,1 2 5 7.5 10. 15 fps l:; 0 2 4 6 8 1.5 2.3 3.0 4.6 mps 10 12 AP 0 7.6 15.2 22.8 30.4 38 45.6 Ipm Flow Rate 5 7.5 10 fps bars psi 11h"(40mm) * 1.5 2.3 3.0 mps H .8 12 bars psi 3/a"(20mm) Flow Rate .7 10 €13 1.5 22 * L .5 8 3 1.2 18 - w .4 6 _ �� E .96 14 m .3 4 y .69 10 a .1 2 a .41 6 all 10 20 30 40 50 60 70 80 90 100 110 120 gpm 14 2 0 38 76 114 152 190 228 266 304 342 380 418 456 1pm 5 7.5 10 15 fps AP 0 5 10 15 20 25 30 35 40 45 50 gpm 1.5 2.3 3.0 4.6 mps 0 19 38 57 76 95 114 133 152 171 1901pm Flow Rate 7.5 15 ((50mm) 2.3 4.6 mps bars psi 2" SOmm bars psi 1"(25mm) * Flow Rate w .8 12 y 1.1 16 0 .7 10 0 .8 12 -I .5 8 0 .7 10 _ .4 6 f ,5 .5 8 H .3 4 y .4 6 m 1 2 ;v .3 4 a 0 0 a .1 2 0 25 50 75 100 125 150 175 200 gpm OP 0 95 190 285 380 475 570 665 760 1pm 0 5 10 15 20 25 30 35 40 45 50 55 60 gpm 5 7.5 10 AP 0 19 38 57 76 95 114 133 152 171 190 209 2281pm - 15 fps 1.5 2.3 3.0 4.6 mps 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate . A. IMPORTANT Inquire with governing authorities for local installation requirements. AM E S 1S0 9001 r'- • FIRE& w WATERWORKS A Division of Watts Industries ww.amesfirewater.corn CERTIFIED �' 875 National Drive • Suite #107 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-2000B 0313 ©Ames Co.2003 Printed in U.S.A.