Permit 11 y
CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT
! 1 ' COMMUNITY DEVELOPMENT Permit#: FPS2015-00054
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 03/26/2015
Parcel: 1 S135AB00900
Jurisdiction: Tigard
Site address: 10200 SW GREENBURG RD 700
Project: Spec Space Subdivision: METZGER,TOWN OF Lot: 9
Project Description: Fire sprinkler,relocate(7)heads,add(1)head&plug(1)head.
Contractor: MCKINSTRY COMPANY LLC Owner: LINCOLN CENTER LLC
16790 NE MASON ST., STE. 100 BY SHORENSTEIN PROPERTIES LLC
PORTLAND, OR 97230 555 CALIFORNIA ST 49TH FL
SAN FRANCISCO,CA 94104
PHONE: 503-331-0234 PHONE:
FAX: 503-331-6907
FEES
Description Date Amount
Specifics: Permit Fee-COM 03/26/2015 $56.47
12%State Surcharge-Building 03/26/2015 $6.78
Type of Use: COM Plan Review-Fire Life Safety-COM 03/26/2015 $22.59
Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 03/26/2015 $0.50
Occupancy Grp: Height: ft 11x17)
Stories:
Commercial Sprinkler System:
Sprinkler Required: Sprinkler Type:
Standpipe Required: Hazard:
Density: 0 Design Area: 0
K Factor: 0
Commercial Fire Alarm System:
Fire Alarm Required: Alarm Type:
Pull Station Required: Smoke Detectors Req:
Battery Calcs Provided: Cut Sheets Required:
Total $86.34
Valuations: Required Items and Reports(Conditions)
Sprinkler Valuation: $700.00
Residential Square Footage: 0
Fire Alarm Valuation: $0.00
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other
applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of
issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon
Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules
or direct questons to OUNC by calling 503.232.1987 or 1.800.332.2344.
Issued By k") re e
_ Permittee Signature: /`� .1 -i
Call 503.639.4175 by 7:00 a.m.for the next available inspec •1 • •.
This permit card shall be kept in a conspicuous place on the job site until completion of the •'roject.
Approved plans are required on the job site at the time of each inspection.
City of Tigard Permit No.: JeSaO/ 5.—COD
:� 13125 SW Hall Blvd.,Tigard,OR 97223
Phone: 503.718.2439 Fax: 503.598.1960 Date Received: I //
i i i,i Inspection Line: 503.639.4175
Internet: www.tigard-or.gov By: --d-k-.
FIRE SPRINKLER AFFIDAVIT FOR ALTERATIONS
OR TENANT IMPROVEMENTS
(1 to 10 SPRINKLER HEADS WITHOUT PLANS)
Project Name: VSP 5�;, 11.)-E) Occupancy:
Job Address: 102,00 Sw (7-1(e n h lc cz3 2,0 0.cL Type of Construction:
Suite:
Contractor: M r_6 x,nS ( . Phone: 5 U 3-331 - 0 23 4
Number of Proposed or Altered Heads: l
Type: 14541 W e.)r Hazard: l\14 1" Density: . kC>
I, PI tn\-0 If1 ■ ? v-%rL Oregon Construction Contractors Board No. ��} 2_e) 1
certify the following is true and reasonably defines the scope of work for this project:
a) All work is limited to drops and armovers in a light-hazard occupancy.
b) Positions of sprinkler heads relative to architectural features such as soffits, beams, partitions, walls, etc.
complies with current adopted edition of NFPA 13.
c) The proposed work does not require hydraulic calculations.
d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be
installed when each head is in a separate fire area).
e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13.
f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13,
Section 8.3.3.1 for exceptions).
g) The installation shall comply with the requirements of the current adopted edition of NPFA 13.
h) Piping shall not be concealed until hangers and bracing are inspected.
i) Final approval shall be subject to onsite tests and inspections.
In addition, I understand the following is required:
• Submit(3) copies of a sketch showing the area of work within the building's structure.
• Building fire protection system permit.
• A copy of this document with a copy of the sketch attached shall be available for all inspections.
Signatur•• ____ Date: 31 244 1 S
Print Name: P y\-{-0 Yn7 a_L_
L\Building\Forrns\FireSprinklerAffidavit_071514.docx Page 1 of 1
Building Permit ApplicatioiECEIVEP
Fire Protection System IOR Ill Flat_ I tiI. O\1.1
City of Tigard MAR 2 6 2015 Received 0� _ ��
DateB .1 % Permit No.: �/S
III
- ■ 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Other Permit
Phone: 503.718.2439 Fax: 503.59 .i , / A u 1 Date/13 t Other
® Page 2 for
Inspection Line: 503.639.4175 '1 i i 'Jr TIGARD Date Ready/By:
TIGARD p BUILDING DIVISION Notified/Method: Supplemental Information
Internet: www.tigard-or.gov , PP
TYPE OF WORK REQUIRED DATA 1-AND 2-FAMILY DWELLING
❑New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
Valuation: $
❑ I-and 2-family dwelling ®Commercial/industrial
El Accessory building ❑Multi-family Number of bedrooms:
El Master builder El Other:
Number of bathrooms:
/690th JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address:A.0220*SW Greenburg Road New dwelling area: square feet
City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.:4t7'70O Project name: OA e_ ,11)/7 Li Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA COMNIERCLAL-USE CHECKLIST
Subdivision: J Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Relocate 7,add 1 and plug 1 sprinkler head. Valuation: $700.00
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER ❑ TENANT Number of stories:
Name:Shorenstein Realty Services,L.P. Type of construction:
Address: 10220 SW Greenburg Road,Suite 310 Occupancy groups:
City/State/ZIP:Portland,OR 97223 Existing:
Phone:(503)619-3100 Fax:( ) New:
r� ,, ►$) �, ' ® CONTACT PERSON NOTICE
Business name:McKinstry Co. All contractors and subcontractors are required to be
Contact name:Antonija Krizanac licensed with the Oregon Construction Contractors Board
under ORS 701 and may be required to be licensed in the
Address: 16790 NE Mason Street,Suite 100 jurisdiction in which work is being performed.If the
City/State/ZIP:Portland,OR 97230 applicant is exempt from licensing,the following reasons
apply:
Phone:(503)331-0234 Fax::(503)331-6906
E-mail:antonijak @mckinstry.com
Lk j-s_ CONTRACTOR -� �u,, . t la1 € a l aS 4
Business name:McKinstry Co.
Permit fee:
Address: 16790 NE Mason Street,Suite 100
State surcharge(12%of permit fee):
City/State/ZIP:Portland,OR 97230 0
FLS plan review(40%of permit fee):
Phone:(503)331-0234 Fax:(503)331-6906 (Due upon application submittal.)
CCB lic.:172811 Total permit fees: .�J
Amount received: f7 g6.5e/
Authorized signatur
This permit application expires if a permit is not obtained
Print name: Date: within 180 days after it has been accepted as complete.
✓1 h 1 } h Z—C)/1 C-L— Z(,t (1 * Fee methodology set by Tri-County Building Industry
Service Board.
I1 Building\Permits\FPS-PermitApp_071514.doe 440-4613T(11/02/COM/WEB)
City of Tigard: Fire Protection Permit Checklist
Page 2- Supplemental Information
Describe work to be done:
1.) Type of\\'ork: 2.) Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices:
❑ New system Number of sprinkler heads: 9 Number of alarm devices:
❑ Addition or ® 1-10 heads: Affidavit required and ❑ 1-5 devices: Affidavit required and
Alteration (3) copies of sketch showing area (3) copies of sketch showing area
to existing of work within building structure of work within building structure
system
❑ 11+ heads: Plan review required and ❑ 6+ devices: Plan review required and
(3) sets of plans. (3) sets of plans.
Additional description of work:
Type of System (Complete A, B, C or D as applicable):
A.) Commercial Sprinkler
® vV(-t ❑ Dn-
Additional Standpipes
Information: Hazard Group Light
Density .10
Design Area 1500
K. Factor 5.6
Sprinkler Project Valuation: $ 700
B.) Type I - Hood Fire Suppression System
Hood Project Valuation: $
C.) Fire Alarm
Submittal shall Battery Calculations ❑ Yes
include: Individual Component ❑ Yes
Cut Sheets
Fire Alarm Project Valuation: $
D.) Residential Sprinkler (Stand Alone System)
Square Footage: Permit Fee:
0 to 2,000 $198.75
2,001 to 3,600 $246.45
3,601 to 7,200 $310.05
7,201 and greater $404.39
Sprinkler Project Square Footage: sq. ft.
Fire Protection Permit Fees _
Project valuation subtotal (see A,B &C above): $
Permit fee based on project valuation (see fee schedule): $
Permit fee based on square footage (see D above): $
State Surcharge (12% of permit fee): $
FLS Plan Review(40% of permit fee): $
TOTAL: $
W:\Projects\N-R\Russell Construction\101991 VSP Suite 700,5 Lincoln\001 Mechanic Const ruction\Permits\FPS-PermitApp.doc
..., a O
e
efl � C
c. c4 ° K,
cw.1 z Et10
az
5 LINCOLN
p - h t PA tt _ 6° ' 10200 SW Greenburg Road
' �`' t ,,.(lit s2 Portland, Oregon 41,ayk,
JU &z p-1,,,../.r s 141 .
s 7 G 1 OGvI;5 4v ( ' " t '
111 13
1441Atill
iiiii amen
!Nisiiiisit
'11 1iri::■ Milli I; !NhIIILTh/ - 4- .
4.1 Illiill
■
In, , .ivii, .1.1kil iiiiii-- -,--: ,..-_-__-:_---_ - i. e nbI t�. F rs.■i.".1111111.....
, iiiNi11111111111111110:- 61' .. ...._-IPAINIPmilli.E""Igh — ilistimmrtimmi
,,,,..„..,..,, si,.., .. ______. Ofhlinilli),- -- . 414i ii
(22...loced-e -1-
piol I
SUITE 700
Approximately 9,461 RSF
. SPI . . .
1111111111 __Lry_ ,A' . N
Floor 111 fidr:LI . igil
7 . ■
Lill ® 7•'—T3 I!IIII!
AM Z • J
Location:
Record Type:
Inspection Type:
Result:
Comments:
Inspection Date:
Record ID:
Inspector:
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223 Tel: 503.718.2439
10200 SW GREENBURG RD 700, TIGARD, OR,
97223
Commercial - Fire Protection System
999 Sprinkler final
PASS - No C of O
FPS2015-00054
Jeff Grove
Violation Summary:
Inspector Contractor