Permit 14 v CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2015-00028 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 03/26/2015 Parcel: 1 S134CD01800 Jurisdiction: Tigard Site address: 12020 SW 118TH AVE Subdivision: LERON HEIGHTS NO.3 Lot: 46 Project: COMSTOCK Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $0.00 Rear 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'l 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: COMSTOCK,DONALD R HELEN SOLARCITY CORPORATION Required Items and Reports(Conditions) 12020 SW 118TH 6132 NE 112TH AVE TIGARD,OR 97223 PORTLAND,OR 97220 PHONE: PHONE: 503-894-6903 FAX: 866-445-7459 Total Fees: $435.98 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notificati•n Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You u: •• -in a copy o r direct questions to OUNC by callin• ill't" 987 0• :'0. .2 •4. Issued By: ��:«�_ — -�— Permittee Signature: �� 1 4 A_ A •'1.639.4175 by 7:00 a.m.for the next available inspection• . This permit card shall be kept in a conspicuous place on the job site until compl- • .roje Approved plans are required on the job site at the time of each inspection - . -, Building Permit Application f Residential ixt ,EIVEI I ,,,L (), i 1( 1 I ',1 ( \1 1 City of Tigard Received i= 2 4 2015 Date • • 13125 SW Hall Blvd.,Tigard,OR flan Revi Phone: 503.718.2439 Fax: 503. Date/B :el" I1 IlagE I I( :\lt t) Inspection Line: 503.639.4 175 { �/I c j. a A Q Date Ready/13 : ® See Page 2 for Internet: www.tigard-or.gov (.11'I `;r ii Notified/Method: min. Supplemental Information TYPF. OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF C'C)NSTRUCCION work indicated on this application. ® I.and 2-family dwelling ❑Commercial/industrial Valuation: S 17,000 ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 12020 SW 118th Ave, New dwelling area: square feet City/State/ZIP: Tigard OR 97223 Garage/carpon area: square feet Suite/bldg./apt.no.: I Project name: Comstock Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure arca: square feet REQI IRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*arc based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. PV ROOF MOUNT Valuation: S Existing building area: square feet New building area: square feet , ® PROPERTY OWNER ❑ TENANT Numberofstories: Name: Comstock, Donald Type of construction: Address: 12020 SW 118th Ave, Occupancy groups: City/State/ZIP: Tigard OR 97223 Existing: Phone:t 503 319 7059 ' Fax:( ) New: ® APPLICANT ® C'Oti fA('1' PERSON BUILDING PERMIT FEES* Business name:SOLAR CITY Meese Wee lo fee schedule) Structural plan review fee(or deposit): Contact name:MELISSA BENTLEY PLS plan review fee(if applicable): Address:6132 NE 112TH AVE City/State/ZIP: Total fees due upon application: ity/State/ZIP:PORTLAND OR 97220 Phone:(503)894 6903 I Fax::(1866)445-7459 Amount received: f-mail:ABI'NTI,F,Y�SOLARC[TY.COM PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRA(TOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:SOLAR CITY Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6132 NE 1121"AVE Solar Installation Specialty Code checklist. City/State/ZIP:PORTLAND OR 97220 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)894-6903 I Fax:(1866)445-7459 State surcharge(12%of permit fee): $21.60 CCB lie.: 180498 { Total fee due upon application: $201.60 Authorized signature:�i f 0 r This permit application expires if a permit is not obtained within 150 days after it has been accepted as complete. / / *Fee methodology set by Tri-County Building Industry Print name:A. MELISSA TIE, Date:2 2 3 14 Service Board. I:1 Building\PermitslBUP-RESPcrmitApp.doc 02/24/2011 440.4613T(11/02/COM/WEB) - Electrical Permit Applic {1EIVED , ,,,( ,,, , It , , ,, t t\I 1 City of Tigard _ Received Date/B • V y 1 M 13125 SW Hall 13lvd.,Tigard,oR I 4 2 015 Plan Review r Phone: 503.718.2439 Fax: 503.598.1960 pp�6 : Other Parfait: Inspection Line: 503.639.41 5 Date Ready/By: 0 See Page 2 for Internet: www.tigard-or.gov v� 11�A f1 Naified/Mdhod; UM Supplemental Information iaitipacowtsforii PIAN REVIEW ❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked below): El Demolition El Other: ❑Service or feeder 400 amps or more 0 Building over three stories. where the available fault current ❑Marinas and boatyards. CATEcoav OF COPIIIITRUCI1ON exceeds 10,000 amps at 150 volts or ❑Floating buildings. ® 1-and 2-family dwelling ❑Commercial/industrial CI Accessory building lesstoground, exceeds 1n ❑Commercial use agricultural amps for installations.r inslallatis, buildings. ❑Multi-family 0 Master builder ❑Other: ❑Fire pump. ❑Installraion of ISO KVA or JOB 817E INFORMATION AND LOCATION O Emergency system. larger separately derived syslcm. ❑Addition of new motor load of ❑"A' "E",.'1-2 '.1-3„ Job no.: 9722380 Job site address: 12020 SW 118th Ave, t armors. Rca ❑Six ox a more residential units. ❑Reccreatioy onal vehicle parks. City/State/ZIP: Tigard OR 97223 ❑Health-care facilities. ❑Supply voltage for mere than ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.: Project name: Comstock ❑Service or feeder 600 amps or more. FEE SCHEMA Cross street/directions to job site: Description I Otr. I Fee, I Trust I • , New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: 1 Lot no.: 1,000 sq.R.or less 168.54 , 4 Ea.add'l 500 sq.ft.or portion 33.92 1 Tax map/parcel no.: Limited energy,residential 75.00 2 DESCRIPTION OF WORK (with above sq.ft.) Limited energy,multi-family 75.00 2 PV ROOF MOUNT residential(with above W.n) Renewable Energy IR See Page 2 Services or feeders installs•, alteration,and/or relocation +s, PROPERTY OWNER I ❑ TENANT 200 amps or less 100.70 2 201 amps to 400 amps 133.56 2 Name: Comstock, Donald 401 amps to 600 amps 200.34 2 Address: 12020 SW 118th Ave, 601 amps to 1,000 amps 301.04 2 Over 1,000 amps or volts 552.26 2 City/State/ZIP: Tigard OR 97223 Temporary services or feeders installation,alteration,and/or Phone:(503 )319 7059 ( Fax:( ) relocation 20 200 amps or less 59.36 1 Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits—new,alteration,or extension,per panel me APPLICANT I ,_' SAC. PERSON A.Fee for branch circuits with above service or feeder fee, 7 42 2 Business name:SOLAR CITY CORP each branch circuit B.Fee for branch circuits without Contact name:A. MELISSA BENTLEY service or feeder fee,first 56.18 2 branch circuit Address:6132 NE 112TH AVE Each add'I branch circuit 7.42 2 City/State/ZIP:PORTLAND OR 97220 Miscellaneous(service or feeder not included) Each manufactured or modular 67.84 2 Phone:(503)894 6903 Fax: :(1866)445 7459 dwelling,service and/or feeder Reconnect only 67.84 2 E-mail:ABENTLEY@SOLARCITY.COM Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name:SOLAR CITY CORP. Signal circuit(s)or limited-energy See panel,alteration,or extension. Page 2 2 Address:6132 NE 112TH AVE Each additional inspection over allowable in any of the above City/State/ZIP:PORTLAND OR 97220 Additional inspection(1 hr min) 66.251 hr ' Investigation(I hr min) 66.25/hr Phone:(503)894 6903 Fax:(1866)445 7459 Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is gO,00/hr CCB Lie.: 180498 Electrical Lie.: C562 Suprv.Lie.: 5873S specifically listed('A hr mm) ELECTOCAL-MONT MUM Suprv.Electrician signature,required: 01-1.-"—W. Subtotal: Print name: NICHOLAS ARMSTRONG Date: Plan review(25%of permit fee): 2 12 3 115 — State surcharge(12%of permit fee): Authorized signature: r4 " TOTAL PERMIT FEE: Print name: A. MELISSA BENTLEY 7 Date: 15/ This permit applicaden expires if a permit is not obtained within Igo 2 2 3 a days after it has been accepted as complete. • Number of inspections allowed per permit. I1Buildinaq'pmitslELC Pera.itApp_ELR ERE..doe Rav0S/212013 440.4615T(11/O5/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WW .KONUY. SEE:SCIIEDT1l.ly Fee for all residential systems combined $75.00 Description I ow. I Pet -I T«:i I • Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 1 . 200.34 200.34 2 ❑ Burglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301.04 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fcc in accordance with 553.26 2 ❑ Heating,Ventilation and Air Conditioning OAR 918-309-0040) System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva no additional charge 0.0 3 ❑ Each additional inspection over allowable in any of the above: Other: Each additional inspection is charged at an hourly(1 hr min) 66.25/hr I Inspections for which no fee is 90 00/hr specifically listed(Y:hr mina COIV>f : RCLAL WORK ONLN: 1aEGTRfCAt f?ERNtIT FEES Fee for each commercial system $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fcc): Stale surcharge(12%ofpermit fcc): Check Type of Work Involved: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within ISO ❑ Audio and Stereo Systems days after it has been accepted as complete. • Numbex of inspections allowed per permit. ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation n H• VAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ N• urse Calls ❑ O• utdoor Landscape Lighting* ❑ Protective Signaling El Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I'IiuitdiuLU'ermiid.ELC PcrmitApp ELR ERE.dac Rev 051:1/2013 City of Tigard Building Division 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T I G A IZ D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12020 SW 118th Ave, City: Tigard OR Zip: 97223 Owner's Name: Comstock,Donald Date: 02/23/15 Contractor's Name: SOLAR CITY CCB #: 180498 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure ® Yes If"Yes",qualifies for "C"or less? El No the prescriptive path. Installations on detached Is the Ground Snow • single/two-family Load 70 psf or less? dwelling/single/two- If"Yes",qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above ❑ No 1 I:'I3uilding/Forms/PhotoVoltaic-Checklist.docx Is the construction material wood and does ® Yes Type of If"Yes",qualifies for the construction qualify Construction El No the prescriptive path. as"conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® If"Yes",qualifies for the prescriptive path. ® No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes",qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes If"Yes",qualifies for with Section 305.4(3)of No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types • material roofing material shingle/shake checked,qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly If"Yes",qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Check list.docx Is the gauge 26 or less? n Ycs If"Yes",qualifies for LI No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel is less than 18 inches, panels? 18 inches or less qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? I Yes the prescriptive path. No Is the roof decking of WSP min. t/2"thickness, n Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof Yes the prescriptive path. surface. n No 3 I:/Building/Forms/PhotoV oltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines,and,as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: 41111111111Malt 6— Model Number: Q Listing Agency: u11703 4 I:Building/Forms/PhotoVoltaic-Checklist.docx