Loading...
Report 7409 SW Tech Center Dr,Ste. 145 C.... Tigard,OR 97223 Ph:503-443-3799 Fax:503-620-2748 503.443.3799 Special Inspection Final Report Date:03-25-2015 Job# 15-5585 Permit#MST-2015-00023 Mail To: Project: ALPENGLOW CONSTRUCTION HAGLUND RESIDENCE 8105 SW 71ST AVE 11270 SW QUELLE PL PORTLAND, OR 97223 TIGARD, OR 97223 To Whom It May Concern: ACS Testing, Inc. attests that their inspectors performed special inspection(s)on a continuous and/or Periodic basis as required by the specific jurisdiction and/or IBC. Special inspection(s)were performed For the following: Proprietary Anchors—Adhesive Based on personal observation, inspection and reports reviewed by me for the above project, I attest on behalf of ACS that work was performed to the best of my knowledge, in accordance with approved plans, specifications, and the applicable codes and standards for the jurisdiction. rdn . Approved by: Bob Brown/President BB/KP ACCREDITED /11S—r a'140/c 7409 SW Tech Center Dr. Ste. 145 Tigard.OR.97223 SMOLT Ph:503-443-3799 Fax:503-620-2748 °"°"REIlf DAILY FIELD REPORT FOR PROPRIETARY ANCHORS OILS l'ESTING, INC 503.443.3 799 Date: Mar 19, 2015 Permit#: MST-2015-00023 ALPENGLOW CONSTRUCTION HAGLUND RESIDENCE 8105 SW 71ST AVE Continuous / 11270 SW QUELLE PL PORTLAND, OR 97223 TIGARD, OR 97223 Periodic Inspector/Certification # Greg Crain Cert# OBOA 856 ACS Job # 15-5585 Anchor Embedded in: Concrete Is this a re-inspection?: I I Yes 0 No Compressive Strength: EXISTING UNKNOWN Approved plans available?: 0 Yes ❑ No HOLE DETAIL/CONDITION Work acceptable per approved plans?: I✓I Yes ❑ No Anchor 5/8„ Hole 0: 3/4" Embed 8" Installation complies with Size: Depth: p manufacturer's evaluation report?: n Yes No Holes cleaned properly?: I✓I Yes No LOCATION OF ANCHORS Embedment per plans?: I✓] Yes No GRIDLINES NA/Garage Wing-Walls INSTALLATION ESR REPORT# GRIDLINES ESR-2508 SET-XP EPDXY FOR CRACKED CONCRETE GRIDLINES TYPE OF ANCHOR: Galvanized All-Thread IS THERE AN RFI? I I Yes 171 No EPDXY TYPE: Set-XP RFI ATTACHED? I I Yes 0 No EXP. DATE: 10/2016 INSPECTION DETAILS: An ACS representative arrived on site as scheduled to monitor installation of(4) (2 each side) 5/8"diameter x 10"length galvanized all- thread rods for new Simpson HDUZ brackets. Work completed per detail 1/S2 (Rev 0) Foreman notified of Yes I No I✓l N/A nonconformance items? MAR 2 3 2015 Foremans Name: Bob w/Alpenglow Reviewed Date: cc: 03/20/2015 Bob McCurdy Bob Brown, President BB/AS Arrocnrrcn 0-w, .!�� 12480 SW 68th Ave. Tigard, Oregon 97223 /01_s -60673 Consulting Engineers Phone: 503-968-9994 3truc kuraL Engineering Fax: 503-968-8444 March 23, 2015 Bob McCurdy Alpenglow Construction 8105 SW 71St Ave Portland, OR 97223 Re: 11270 SW Quelle Place Tigard, OR HCE Project #15048 Dear Bob, As you requested, a representative of Hayden Consulting Engineers looked into the reuse of the existing header at the above address in the repair previously designed by our company. We find that it is structurally acceptable to reuse the 4 x 16 (actual dimensions 3.5" x 15.25") solid sawn header in place of the previously design 3 1/2 x 12 glulam. This is under the assumption that the existing header was not damaged along with the other areas being repaired. 3\,Z aUcTUR,q 4 If you have any questions, please do not hesitate to call. PROF 4, „, G4'4% gi Sincerely, _ Hayden Consulting Engineers, Inc. –... Apr t c zoo�� R. HP° XP: 6/30/ JS By: i - By:..� —^ -- She '.'y Richt'rds I Darron R. Hayden, P. :. Structural Design-r Principal Hayden Consulting Engineers, Inc.