Report • dah3 •I • RECEIVED Mil Date: February 03, 2015 MAR 16 2015 MORRISON HERSHFIELD Mr. Brandon Coffey Morrison Hershfield Crown Castle CITY OF TIGARD 1455 Lincoln Parkway, Suite 500 5350 North 48th Street, Suite 3o5BUILDING DIVISION Atlanta, GA 30346 Chandler, AZ 85226 (770)379-8500 Subject: Structural Analysis Report Carrier Designation: AT&T Mobility Co-Locate Carrier Site Number: Pr91 Carrier Site Name: Scholls Ferry Beef Bend Crown Castle Designation: Crown Castle BU Number: 855864 Crown Castle Site Name: Scholls Ferry Beef Bend Crown Castle JDE Job Number: 321260 Crown Castle Work Order Number: 1000782 Crown Castle Application Number: 280246 Rev. 0 Engineering Firm Designation: Morrison Hershfield Project Number: CN4-226/6150003 Site Data: 17026 Southwest Friendly Lane, Beaverton,Washington County, OR Latitude 45°25'32.01", Longitude -122°51'7.53" 78.5 Foot-Monopole Tower Dear Mr. Coffey, Morrison Hershfield is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 751199, in accordance with application 280246, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case,to be: LC7: Existing + Proposed for all applicants Sufficient Capacity Note:See Table I and Table II for the proposed and existing/reserved loading,respectively. This analysis has been performed in accordance with the 2014 Oregon Structural Specialty Code (OSSC) based upon an ultimate 3-second gust wind speed of 120 mph converted to a nominal 3-second gust wind speed of 93 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C with a maximum topographic factor, Kzt, of 1.0 and Risk Category II were used in this analysis. We at Morrison Hershfield appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Respectfully submitted by: co „‘ E- G NEFR (/ 2 51504PE r G. Lance Cooke, P.E. (OR License No. 51504PE) Senior Engineer ^9,L� IEGO x/17 • \, `1Y1' •tnxTower Report-version 6.1.4.1 Felff)&11 1(fN DATE: e) TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2- Existing and Reserved Antenna and Cable Information Table 3-Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4-Documents Provided 3.1)Analysis Method 3.2)Assumptions 4) ANALYSIS RESULTS Table 5-Section Capacity(Summary) Table 6—Tower Components vs. Capacity 4.1)Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations tnxTower Report-version 6.1.4.1 r February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CC/BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 3 1) INTRODUCTION V This tower is a 78.5 ft monopole tower designed Paul J. Ford and Company, in February of 1999. The tower was originally designed for a wind speed of 90 mph per TIA/EIA-222-F. 2)ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 93 mph with no ice, 30 mph with 1 inch ice thickness and 60 mph under service loads, exposure category C with topographic category 1. Table 1 -Proposed Antenna and Cable Information Center Feed Number Mounting Line Number of Antenna Line Level (ft) Elevation Antennas Manufacturer Antenna Model of Feed Size Note (ft) Lines (in) 3 Alcatel Lucent 9442 RRH 700 3 I Alcatel Lucent RRH2x40-07-L 85.0 r 3 Alcatel Lucent RRH4x25-WCS II 1 Raycap 1 DC6-48-60-18-8F 2 3/8 80.0 - 3 Alcatel Lucent 13JR52703AAAA w/pipe mount 4 3/4 82.0 1 3 I Kathrein I 800-10866 w/pipe mount 1— - I Miscellaneous [NA 509-3] 80.0 I 1 I I Miscellaneous [NA 510-1] Table 2 -Existing and Reserved Antenna and Cable Information Center Number Number Feed Mounting Line Antenna Line of Antenna Model of Feed Note Level (ft) Elevation Antennas Manufacturer Lines Size (ft) (in) 3 j Alcatel Lucent 9442 RRH 1 Powerwave 3 1/2 6 Technologies LGP 21403 4 3/4 3 85.0 Powerwave 6 Technologies LGP21401 6 7/8 1 1 I Raycap DC6-48-60-18-8F 6 1-5/8 1 KMW AM-X-CD-16-65-00T-RET w/ r 3 80.0 Communications pipe mount F 3 Kathrein I 742-265 w/pipe mount 82.0 AP14/17- 1 3 Kathrein 880/1940/065D/ADT/XXP - - w/Mount Pipe 2 Powerwave P65-17-XLH-RR w/pipe mount 3 Technologies I 80.0 1 - Platform Mount[LP 1001-1] I 1 3 1 - I T-Arm Mount[TA 701-1] 6 Andrew 850/1900 DUAL BAND TMA 12 7/8 1 60.0 60.0 3 Antel BXA-70063/8CF w/pipe mount 3 Antel BXA-80080/8CF w/pipe mount 1 13/32 2 3 I CSS I AXP18-80-0 w/pipe mount �i tnxTower Report-version 6.1.4.1 r February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 4 Center Number Number Feed Mounting Line Antenna Line Antenna Model of Feed of Note 4 Level (ft) Elevation Manufacturer Size (ft) Antennas Lines (in) 3 CSS 1 XP18-80-0 w/pipe mount r I 1 3 Ericsson I- RRUS-11 - - 2 1 Raycap I RCMDC-3315-PF-48 - 40.0 f 40.0 I 1 I GPS i-Slde Arm GPS ASO 701-1j 1 1/2 1 Notes: 1) Existing equipment that is to remain on the tower. 2) This equipment is reserved and has been considered in this analysis. 3) The existing equipment is to be removed and has not been considered in the calculations for this analysis. Table 3-Design Antenna and Cable Information Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size(in) (ft) 78.5 78.5 - - 3/4 Lightning Rod - - 85.25 I 85.25 I 4 I Celwave I PD10041 I - I - 80 80 ( - 116-Ft Platform w/Handrails - - 1 12 Celwave PD10201 I 65.25 I 65.25 4 I Celwave I PD10041 I - - 60 60 f - [ 16-Ft Platform w/Handrails - - 12 Celwave r PD10201 40 I 40 I 1 I - I HP-6 I - I - 3) ANALYSIS PROCEDURE Table 4-Documents Provided Document Remarks Reference Source 4-GEOTECHNICAL REPORTS Redmond&Associates, Project 5532600 CCISITES No.110.086.G, Dated 03/13/1997 4-TOWER FOUNDATION Moffatt, Nichol &Bonney, Inc., Project 5532605 CCISITES DRAWINGS/DESIGN/SPECS No.P5822, Dated 02/17/1999 4-TOWER MANUFACTURER Fort Worth Tower, Inc., Project No. 5532607 I CCISITES DRAWINGS 19030000, Dated 02/25/1999 4-TOWER STRUCTURAL Morrison Hershfield, Project No.ATT- 5148639 I CCISITES ANALYSIS REPORTS 609/6140035, Dated 11/19/2013 3.1) Analysis Method tnxTower(version 6.1.4.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CC!BU No 855864 Project Number CN4-226/6150003,Application 280246,Revision 0 Page 5 3.2) Assumptions 1) The tower and structures were built in accordance with the manufacturer's specifications and applicable ANSI/TIA/EIA standards. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) The foundation was properly designed and constructed for the original design loads. This analysis may be affected if any assumptions are not valid or have been made in error. Morrison Hershfield should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 5-Section Capacity(Summary) Section Component Critical PP allow No. Elevation(ft) Type Size Element P(� (I) Capacity Pass/Fail L1 78.5-49.33 Pole TP28.012x18.87x0.1875 1 -10.41 1054.59 59.1 Pass L2 49.33-0 Pole TP43.1x26.4868x0.3125 2 -19.60 2861.65 50.9 Pass Summary Pole(L1) 59.1 Pass I r 1 I I Rating= I 59.1 I Pass Table 6 -Tower Component Stresses vs. Capacity—LC7 Notes Component I Elevation(ft) %Capacity Pass/Fail 1 1 Anchor Rods j 0 40.8 I Pass 1 I Base Plate 0 I 24.2 I Pass 1 [Foundation Bearing I 0 II 59.4 r Pass 1 Foundation 0 I 42.1 I Pass Overturning Structure Rating(max from all components)= 59.4% Notes: 1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity consumed. 4.1) Recommendations The tower and its foundation have sufficient capacity to carry the existing, reserved and proposed loads. No modifications are required at this time. tnxTower Report-version 6.1.4.1 APPENDIX A TNXTOWER OUTPUT tnxTower Report-version 6.1.4.1 t I W. p DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION 78 5 ft -- 742-285 w/pipe mount 80 006-48-60-18-8F 80 742-265 w/pipe mount 80 Miscellaneous[NA 510-1] 80 742-265 w/pipe mount 80 Miscellaneous[NA 509-3] 80 0P14/17-880/1940/065D/ADT/xXP 80 XP18-80-0 w/pipe mount 60 w/Mount Pipe XP18-80-0 w/pipe mount 60 _ AP14/17-8801 1940/065D/ADTOO(P 80 XP18-80-0 w/pipe mount 60 w/Mount Pipe BXA-70063/8CF w/pipe mount 60 AP14 117-880/1940/065D/ADT/)0(P 80 BXA-70063/8CF w/pipe mount 60 w/Mount Pipe - BXA-70063/8CF w/pipe mount 60 (2)LGP21401 80 . (2)LGP21401 80 (2)850!1900 DUAL BAND TMA 60 (2)LGP21401 80 (2)850/1900 DUAL BAND TMA 60 80 DC6-4860-18-8F 80 (2)850/1900 DUAL BAND TMA 60 Platform Mount[LP 1001-1] 80 T-Arm Mount[TA 701-1] 60 n 800-10866 w/pipe mount 80 T-Arm Mount[TA 701-1] 60 o `" 800-10866 w/pipe mount 80 T-Arm Mount[TA 701-1] 60 E. 800-10866 w/pipe mount 80 BXA-80080/8CF w/pipe mount 60 3JR52703AAAA w/pipe mount 80 BXA-80080/BCF w/pipe mount 60 BXA-80080/8CF w/pipe mount 60 I 3JR52703AAAA w/pipe mount 80 3JR52703AAAA w/pipe mount 80 AXP18-860 w/pipe mount 60 (2)RRH2x40-07-L 80 AXP18-80-0 w/pipe mount 60 RRH2x40-07-L 80 AXP18A0-0 w/pipe mount 60 9442 RRH 700 80 RRUS-11 60 9442 RRH 700 80 RRUS-11 60 / 9442 RRH 700 80 RRUS-11 60 RRH4x25-WCS 80 RCMDC-3315-PF-48 60 RRH4x25-WCS 80 GPS A 40 49.3 ft RRH4x25-WCS 80 Side Arm Mount[SO 701-1] 40 MATERIAL STRENGTH GRADE Fy _ Fu GRADE Fy Fu A572-65 65 ksi 80 ke: Q TOWER DESIGN NOTES b 1. Tower is located in Washington County,Oregon. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 93 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 1.00 in ice.Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING:59.1% ALL REACTIONS ARE FACTORED AXIAL 43 K SHEAR MOMENT 2 K j J 149 kip-ft TORQUE 0 kip-ft 30 mph WIND-1.0000 in ICE AXIAL 20 K EAR MOMENT 19 19 K r+ 1265 kip-ft 0.0 ft TORQUE 1 kip-ft N :_='_ a REACTIONS-93 mph WIND C o t3 J ` C g 9 w E x 3 0 I a A 3 2' m0 S r9 3 Ira 1 i Morrison Hershfield job;CN4-226/6150003 1455 Lincoln Parkway,Suite 500 Prye t:855864/Schols Ferry Beef Bend Atlanta,GA 30346 cl1Bnt:Crown castle USA Drawn by SB APO Consulting Engineers Phone:(770)379-8500 code-TIA-222-G Date:02/03/15 scale: Ni FAX:(770)379-8501 Path: Dwg No E February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CC/BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 7 Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Washington County, Oregon. Basic wind speed of 93 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Nominal ice thickness of 1.0000 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50 F. Deflections calculated using a wind speed of 60 mph. A non-linear(P-delta)analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads,feed line supports, and appurtenance mounts are not considered. Options Consider Moments-Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder Consider Moments-Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules Consider Moments-Diagonals ' Assume Rigid Index Plate Calculate Redundant Bracing Forces Use Moment Magnification 11 Use Clear Spans For Wind Area Ignore Redundant Members in FEA 'l Use Code Stress Ratios Use Clear Spans For KUr SR Leg Bolts Resist Compression Ai Use Code Safety Factors-Guys Retension Guys To Initial Tension All Leg Panels Have Same Allowable Escalate Ice NI Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz NI Use Azimuth Dish Coefficients 11 Consider Feedline Torque Use Special Wind Profile NI Project Wind Area of Appurt. Include Angle Block Shear Check Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles Leg Bolts Are At Top Of Section SR Members Have Cut Ends NI Include Shear-Torsion Interaction Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets Add IBC.6D+W Combination Use TIA-222-G Tension Splice Capacity Exemption Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L1 78.50-49.33 29.17 3.67 18 18.8700 28.0120 0.1875 0.7500 A572-65 (65 ksi) L2 49.33-0.00 53.00 18 26.4868 43.1000 0.3125 1.2500 A572-65 (65 ksi) Tapered Pole Properties Section Tip Dia. Area I r C I/C J It/Q w w/t in in2 in' in in in' in' in2 in L1 19.1611 11.1184 490.2873 6.6323 9.5860 51.1464 981.2197 5.5603 2.9911 15.953 tnxTower Report-version 6.1.4.1 • February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 8 Section Tip Dia. Area I r C 1/C J It/Q w w/t in in2 in' in in in' in' in2 in .r 28.4441 16.5591 1619.6745 9.8777 14.2301 113.8204 3241.4803 8.2811 4.6001 24.534 L2 28.0635 25.9616 2247.0873 9.2919 13.4553 167.0039 4497.1315 12.9833 4.1117 13.157 43.7649 42.4399 9816.2392 15.1896 21.8948 448.3366 19645.394 21.2240 7.0356 22.514 8 Tower Gusset Gusset Gusset GradeAdjust.Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness A, Factor Stitch Bolt Stitch Bolt (per face) Ar Spacing Spacing Diagonals Horizontals ft ft2 in in in L1 78.50- 1 1 1 49.33 L2 49.33-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Secto Component Placement Total Number Start/En Width or Perimete Weight r Type Number Per Row d Diamete r ft Position r Of in in Safety Line 3/8" A Surface Ar 78.50-10.00 1 1 0.000 0.3750 0.22 (CaAa) 0.000 Climbing Rungs A Surface Ar 78.50-10.00 1 1 -0.100 0.7050 1.80 (CaAa) 0.100 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg ft ft2/ft plf LDF5-50A(7/8") C No Inside Pole 78.50-7.00 6 No Ice 0.00 0.33 1/2"Ice 0.00 0.33 1"Ice 0.00 0.33 LDF7-50A(1-5/8") C No Inside Pole 78.50-7.00 6 No Ice 0.00 0.82 1/2"Ice 0.00 0.82 1"Ice 0.00 0.82 FB-L98B-002-XXX( C No Inside Pole 78.50-7.00 2 No Ice 0.00 0.06 3/8) 1/2"Ice 0.00 0.06 1"Ice 0.00 0.06 WR-VG86ST-BRD( C No Inside Pole 78.50-7.00 4 No Ice 0.00 0.58 3/4) 1/2"Ice 0.00 0.58 1"Ice 0.00 0.58 LDF5-50A(7/8") A No Inside Pole 60.00-7.00 12 No Ice 0.00 0.33 1/2"Ice 0.00 0.33 1"Ice 0.00 0.33 _ RFF-16SM-808-418- A No Inside Pole 60.00-7.00 1 No Ice 0.00 0.75 APE(1 3/32") 1/2"Ice 0.00 0.75 1"Ice 0.00 0.75 LDF4-50A(1/2") C No Inside Pole 40.00-7.00 1 No Ice 0.00 0.15 1/2"Ice 0.00 0.15 1"Ice 0.00 0.15 tnxTower Report-version 6.1.4.1 ■ February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246,Revision 0 Page 9 Feed Line/Linear Appurtenances Section Areas 0 Tower Tower Face AR AF CAAA CAAA Weight Sectio Elevation In Face Out Face n ft ft2 ft2 ft2 K L1 78.50-49.33 A 0.000 0.000 3.150 0.000 0.11 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 0.000 0.27 L2 49.33-0.00 A 0.000 0.000 4.248 0.000 0.28 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 0.000 0.40 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice AR AF CAAA CAAA Weight Sectio Elevation or Thickness In Face Out Face n ft Leg in ft2 ft2 ft2 ft2 K L1 78.50-49.33 A 2.133 0.000 0.000 28.044 0.000 0.52 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 0.000 0.27 L2 49.33-0.00 A 1.937 0.000 0.000 37.812 0.000 0.83 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 0.000 0.40 Feed Line Center of Pressure Section Elevation CPx CPz CPx CPz Ice Ice ft in in in in L1 78.50-49.33 -0.1343 -0.0776 -0.7564 -0.4367 L2 49.33-0.00 -0.1041 -0.0601 -0.6926 -0.3999 Shielding Factor Ka Tower Feed Line Description Feed Line Ka Ka Section Record No. Segment No Ice Ice Elev. L1 1 Safety Line 3/8" 49.33- 1.0000 1.0000 78.50 L1 2 Climbing Rungs 49.33- 1.0000 1.0000 78.50 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t Vert ft ft ft2 ft2 K ft ° ft 742-265 w/pipe mount A From Leg 4.00 0.0000 80.00 No Ice 8.10 6.52 0.09 -6.00 1/2" 8.77 7.82 0.16 2.00 Ice 9.48 8.97 0.23 1"Ice 742-265 w/pipe mount B From Leg 4.00 0.0000 80.00 No Ice 8.10 6.52 0.09 -6.00 1/2" 8.77 7.82 0.16 2.00 Ice 9.48 8.97 0.23 1"Ice 742-265 w/pipe mount C From Leg 4.00 0.0000 80.00 No Ice 8.10 6.52 0.09 tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 10 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t 'V Vert ft ft ft ft2 K ft ° ft -6.00 1/2" 8.77 7.82 0.16 2.00 Ice 9.48 8.97 0.23 1"Ice AP14/17- A From Leg 4.00 0.0000 80.00 No Ice 5.81 4.17 0.06 880/1940/065D/ADT/XXP 2.00 1/2" 6.50 5.21 0.11 w/Mount Pipe 2.00 Ice 7.08 5.97 0.16 1"Ice AP14/17- B From Leg 4.00 0.0000 80.00 No Ice 5.81 4.17 0.06 880/1940/065D/ADT/XXP 2.00 1/2" 6.50 5.21 0.11 w/Mount Pipe 2.00 Ice 7.08 5.97 0.16 1"Ice AP14/17- C From Leg 4.00 0.0000 80.00 No Ice 5.81 4.17 0.06 880/1940/065D/ADT/XXP 2.00 1/2" 6.50 5.21 0.11 w/Mount Pipe 2.00 Ice 7.08 5.97 0.16 1"Ice (2)LGP21401 A From Leg 4.00 0.0000 80.00 No Ice 1.29 0.23 0.01 0.00 1/2" 1.45 0.31 0.02 5.00 Ice 1.61 0.40 0.03 1"Ice (2)LGP21401 B From Leg 4.00 0.0000 80.00 No Ice 1.29 0.23 0.01 0.00 1/2" 1.45 0.31 0.02 5.00 Ice 1.61 0.40 0.03 1"Ice (2)LGP21401 C From Leg 4.00 0.0000 80.00 No Ice 1.29 0.23 0.01 0.00 1/2" 1.45 0.31 0.02 5.00 Ice 1.61 0.40 0.03 1"Ice DC6-48-60-18-8F C From Leg 1.00 0.0000 80.00 No Ice 2.22 2.22 0.02 0.00 1/2" 2.44 2.44 0.04 5.00 Ice 2.66 2.66 0.06 1"Ice Platform Mount[LP 1001- C None 0.0000 80.00 No Ice 47.70 47.70 3.02 1] 1/2" 59.50 59.50 3.62 Ice 71.30 71.30 4.22 1"Ice 800-10866 w/pipe mount A From Leg 4.00 0.0000 80.00 No Ice 14.35 9.93 0.12 -2.00 1/2" 15.28 11.55 0.23 2.00 Ice 16.22 13.19 0.34 1"Ice 800-10866 w/pipe mount B From Leg 4.00 0.0000 80.00 No Ice 14.35 9.93 0.12 -2.00 1/2" 15.28 11.55 0.23 2.00 Ice 16.22 13.19 0.34 1"Ice 800-10866 w/pipe mount C From Leg 4.00 0.0000 80.00 No Ice 14.35 9.93 0.12 -2.00 1/2" 15.28 11.55 0.23 2.00 Ice 16.22 13.19 0.34 1"Ice 3JR52703AAAA w/pipe A From Leg 4.00 0.0000 80.00 No Ice 11.91 14.21 0.16 mount 6.00 1/2" 12.63 15.76 0.27 2.00 Ice 13.36 17.34 0.39 1"Ice - 3JR52703AAAA w/pipe B From Leg 4.00 0.0000 80.00 No Ice 11.91 14.21 0.16 mount 6.00 1/2" 12.63 15.76 0.27 2.00 Ice 13.36 17.34 0.39 1"Ice 3JR52703AAAA w/pipe C From Leg 4.00 0.0000 80.00 No Ice 11.91 14.21 0.16 mount 6.00 1/2" 12.63 15.76 0.27 2.00 Ice 13.36 17.34 0.39 1"Ice (2)RRH2x40-07-L A From Leg 4.00 0.0000 80.00 No Ice 2.12 1.77 0.07 0.00 1/2" 2.32 1.97 0.09 5.00 Ice 2.54 2.17 0.11 1"Ice RRH2x40-07-L B From Leg 4.00 0.0000 80.00 No Ice 2.12 1.77 0.07 tnxTower Report-version 6.1.4.1 • February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246,Revision 0 Page 11 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t . Vert R ft ft2 ft2 K ft ° ft 0.00 1/2" 2.32 1.97 0.09 5.00 Ice 2.54 2.17 0.11 1"Ice 9442 RRH 700 A From Leg 4.00 0.0000 80.00 No Ice 3.53 1.60 0.04 0.00 1/2" 3.80 1.82 0.06 5.00 Ice 4.08 2.06 0.09 1"Ice 9442 RRH 700 B From Leg 4.00 0.0000 80.00 No Ice 3.53 1.60 0.04 0.00 1/2" 3.80 1.82 0.06 5.00 Ice 4.08 2.06 0.09 1"Ice 9442 RRH 700 C From Leg 4.00 0.0000 80.00 No Ice 3.53 1.60 0.04 0.00 1/2" 3.80 1.82 0.06 5.00 Ice 4.08 2.06 0.09 1"Ice RRH4x25-WCS A From Leg 4.00 0.0000 80.00 No Ice 4.45 3.81 0.09 0.00 1/2" 4.77 4.11 0.13 5.00 Ice 5.09 4.43 0.16 1"Ice RRH4x25-WCS B From Leg 4.00 0.0000 80.00 No Ice 4.45 3.81 0.09 0.00 1/2" 4.77 4.11 0.13 5.00 Ice 5.09 4.43 0.16 1"Ice RRH4x25-WCS C From Leg 4.00 0.0000 80.00 No Ice 4.45 3.81 0.09 0.00 1/2" 4.77 4.11 0.13 5.00 Ice 5.09 4.43 0.16 1"Ice DC6-48-60-18-8F A From Leg 1.00 0.0000 80.00 No Ice 2.22 2.22 0.02 0.00 1/2" 2.44 2.44 0.04 5.00 Ice 2.66 2.66 0.06 1"Ice Miscellaneous[NA 510-1] C None 0.0000 80.00 No Ice 6.00 6.00 0.26 1/2" 8.50 8.50 0.34 Ice 11.00 11.00 0.42 1"Ice Miscellaneous[NA 509-3] C None 0.0000 80.00 No Ice 11.84 11.84 0.28 1/2" 16.96 16.96 0.30 Ice 22.08 22.08 0.32 1"Ice XP18-80-0 w/pipe mount A From Leg 4.00 0.0000 60.00 No Ice 4.91 4.83 0.05 0.00 1/2" 5.37 5.75 0.10 0.00 Ice 5.82 6.54 0.15 1"Ice XP18-80-0 w/pipe mount B From Leg 4.00 0.0000 60.00 No Ice 4.91 4.83 0.05 0.00 1/2" 5.37 5.75 0.10 0.00 Ice 5.82 6.54 0.15 1"Ice XP18-80-0 w/pipe mount C From Leg 4.00 0.0000 60.00 No Ice 4.91 4.83 0.05 0.00 1/2" 5.37 5.75 0.10 0.00 Ice 5.82 6.54 0.15 1"Ice BXA-70063/8CF w/pipe A From Leg 4.00 0.0000 60.00 No Ice 10.68 7.88 0.06 mount 0.00 1/2" 11.30 9.28 0.13 0.00 Ice 11.92 10.53 0.22 1"Ice BXA-70063/8CF w/pipe B From Leg 4.00 0.0000 60.00 No Ice 10.68 7.88 0.06 mount 0.00 1/2" 11.30 9.28 0.13 0.00 Ice 11.92 10.53 0.22 1"Ice BXA-70063/8CF w/pipe C From Leg 4.00 0.0000 60.00 No Ice 10.68 7.88 0.06 mount 0.00 1/2" 11.30 9.28 0.13 0.00 Ice 11.92 10.53 0.22 1"Ice (2)850/1900 DUAL BAND A From Leg 4.00 0.0000 60.00 No Ice 2.15 0.48 0.03 tnxTower Report-version 6.1.4.1 • February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 12 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral t ~ Vert ft ft ft2 ft2 K ft ° ft TMA 0.00 1/2" 2.35 0.60 0.04 0.00 Ice 2.55 0.74 0.06 1"Ice (2)850/1900 DUAL BAND B From Leg 4.00 0.0000 60.00 No Ice 2.15 0.48 0.03 TMA 0.00 1/2" 2.35 0.60 0.04 0.00 Ice 2.55 0.74 0.06 1"Ice (2)850/1900 DUAL BAND C From Leg 4.00 0.0000 60.00 No Ice 2.15 0.48 0.03 TMA 0.00 1/2" 2.35 0.60 0.04 0.00 Ice 2.55 0.74 0.06 1"Ice T-Arm Mount[TA 701-1] A From Leg 2.00 0.0000 60.00 No Ice 14.16 9.13 0.36 0.00 1/2" 14.16 12.17 0.47 0.00 Ice 14.16 15.21 0.57 1"Ice T-Arm Mount[TA 701-1] B From Leg 2.00 0.0000 60.00 No Ice 14.16 9.13 0.36 0.00 1/2" 14.16 12.17 0.47 0.00 Ice 14.16 15.21 0.57 1"Ice T-Arm Mount[TA 701-1] C From Leg 2.00 0.0000 60.00 No Ice 14.16 9.13 0.36 0.00 1/2" 14.16 12.17 0.47 0.00 Ice 14.16 15.21 0.57 1"Ice BXA-80080/8CF w/pipe A From Leg 4.00 0.0000 60.00 No Ice 8.47 8.73 0.07 mount 0.00 1/2" 9.17 10.23 0.14 0.00 Ice 9.88 11.76 0.22 1"Ice BXA-80080/8CF w/pipe B From Leg 4.00 0.0000 60.00 No Ice 8.47 8.73 0.07 mount 0.00 1/2" 9.17 10.23 0.14 0.00 Ice 9.88 11.76 0.22 1"Ice BXA-80080/8CF w/pipe C From Leg 4.00 0.0000 60.00 No Ice 8.47 8.73 0.07 mount 0.00 1/2" 9.17 10.23 0.14 0.00 Ice 9.88 11.76 0.22 1"Ice AXP18-80-0 w/pipe mount A From Leg 4.00 0.0000 60.00 No Ice 4.91 4.82 0.05 0.00 1/2" 5.36 5.74 0.10 0.00 Ice 5.82 6.54 0.15 1"Ice AXP18-80-0 w/pipe mount B From Leg 4.00 0.0000 60.00 No Ice 4.91 4.82 0.05 0.00 1/2" 5.36 5.74 0.10 0.00 Ice 5.82 6.54 0.15 1"Ice AXP18-80-0 w/pipe mount C From Leg 4.00 0.0000 60.00 No Ice 4.91 4.82 0.05 0.00 1/2" 5.36 5.74 0.10 0.00 Ice 5.82 6.54 0.15 1"Ice RRUS-11 A From Leg 4.00 0.0000 60.00 No Ice 3.25 1.37 0.05 0.00 1/2" 3.49 1.55 0.07 0.00 Ice 3.74 1.74 0.10 1"Ice - RRUS-11 B From Leg 4.00 0.0000 60.00 No Ice 3.25 1.37 0.05 0.00 1/2" 3.49 1.55 0.07 0.00 Ice 3.74 1.74 0.10 1"Ice RRUS-11 C From Leg 4.00 0.0000 60.00 No Ice 3.25 1.37 0.05 0.00 1/2" 3.49 1.55 0.07 0.00 Ice 3.74 1.74 0.10 1"Ice RCMDC-3315-PF-48 A From Leg 1.00 0.0000 60.00 No Ice 4.42 2.90 0.03 0.00 1/2" 4.72 3.16 0.06 0.00 Ice 5.02 3.42 0.10 1"Ice tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246,Revision 0 Page 13 Description Face Offset Offsets: Azimuth Placement CAAA CAAA Weight or Type Horz Adjustmen Front Side Leg Lateral ✓ Vert ft ft ft2 ft2 K ft ft GPS_A B From Leg 3.00 0.0000 40.00 No Ice 0.30 0.30 0.00 0.00 1/2" 0.37 0.37 0.00 0.00 Ice 0.46 0.46 0.01 1"Ice Side Arm Mount[SO 701- B From Leg 1.50 0.0000 40.00 No Ice 0.85 1.67 0.07 1] 0.00 1/2" 1.14 2.34 0.08 0.00 Ice 1.43 3.01 0.09 1"Ice Load Combinations Comb. Description No. 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg-No Ice 3 0.9 Dead+1.6 Wind 0 deg-No Ice 4 1.2 Dead+1.6 Wind 30 deg-No Ice 5 0.9 Dead+1.6 Wind 30 deg-No Ice 6 1.2 Dead+1.6 Wind 60 deg-No Ice 7 0.9 Dead+1.6 Wind 60 deg-No Ice 8 1.2 Dead+1.6 Wind 90 deg-No Ice 9 0.9 Dead+1.6 Wind 90 deg-No Ice 10 1.2 Dead+1.6 Wind 120 deg-No Ice 11 0.9 Dead+1.6 Wind 120 deg-No Ice 12 1.2 Dead+1.6 Wind 150 deg-No Ice 13 0.9 Dead+1.6 Wind 150 deg-No Ice 14 1.2 Dead+1.6 Wind 180 deg-No Ice 15 0.9 Dead+1.6 Wind 180 deg-No Ice 16 1.2 Dead+1.6 Wind 210 deg-No Ice 17 0.9 Dead+1.6 Wind 210 deg-No Ice 18 1.2 Dead+1.6 Wind 240 deg-No Ice 19 0.9 Dead+1.6 Wind 240 deg-No Ice 20 1.2 Dead+1.6 Wind 270 deg-No Ice 21 0.9 Dead+1.6 Wind 270 deg-No Ice 22 1.2 Dead+1.6 Wind 300 deg-No Ice 23 0.9 Dead+1.6 Wind 300 deg-No Ice 24 1.2 Dead+1.6 Wind 330 deg-No Ice 25 0.9 Dead+1.6 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg-Service 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg-Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 14 Comb. Description No. v 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 deg-Service Maximum Member Forces Sectio Elevation Component Condition Gov. Axial Major Axis Minor Axis n ft Type Load Moment Moment No. Comb. K kip-ft kip-ft L1 78.5-49.33 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -29.24 -0.20 2.16 Max.Mx 8 -10.42 -334.05 0.51 Max.My 2 -10.41 -0.04 335.77 Max.Vy 8 15.84 -334.05 0.51 Max.Vx 2 -15.93 -0.04 335.77 Max.Torque 20 -0.95 L2 49.33-0 Pole Max Tension 1 0.00 0.00 0.00 Max.Compression 26 -43.49 0.23 2.43 Max.Mx 8 -19.60 -1258.47 0.68 Max.My 2 -19.60 -0.30 1265.44 Max.Vy 8 19.03 -1258.47 0.68 Max.Vx 2 -19.13 -0.30 1265.44 Max.Torque 20 -0.95 Maximum Reactions Location Condition Gov. Vertical Horizontal,X Horizontal,Z Load K K K Comb. Pole Max.Vert 26 43.49 -0.00 0.00 Max.H. 20 19.62 19.01 -0.01 Max.H. 2 19.62 -0.01 19.11 Max.M. 2 1265.44 -0.01 19.11 Max.M. 8 1258.47 -19.01 0.01 Max.Torsion 10 0.91 -16.46 -9.55 Min.Vert 19 14.72 16.47 -9.56 Min.H. 8 19.62 -19.01 0.01 Min.H, 14 19.62 0.01 -19.11 Min.M. 14 -1264.00 0.01 -19.11 Min.M. 20 -1257.80 19.01 -0.01 Min.Torsion 22 -0.91 16.46 9.55 Tower Mast Reaction Summary Load Vertical Shear, Shear Overturning Overturning Torque Combination Moment,M. Moment,M„ K K K kip-ft kip-ft kip-ft Dead Only 16.35 0.00 0.00 -0.58 -0.27 0.00 1.2 Dead+1.6 Wind 0 deg- 19.62 0.01 -19.11 -1265.44 -0.30 0.39 No Ice 0.9 Dead+1.6 Wind 0 deg- 14.72 0.01 -19.11 -1259.15 -0.22 0.38 No Ice 1.2 Dead+1.6 Wind 30 deg- 19.62 9.51 -16.56 -1095.98 -629.37 -0.08 No Ice 0.9 Dead+1.6 Wind 30 deg- 14.72 9.51 -16.56 -1090.51 -626.25 -0.08 No Ice 1.2 Dead+1.6 Wind 60 deg- 19.62 16.47 -9.56 -633.05 -1089.89 -0.52 No Ice 0.9 Dead+1.6 Wind 60 deg- 14.72 16.47 -9.56 -629.81 -1084.55 -0.52 No Ice tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 15 Load Vertical Shear, Shear, Overturning Overturning Torque Combination Moment,M, Moment,MM K K K kip-ft kip-ft kip-ft " 1.2 Dead+1.6 Wind 90 deg- 19.62 19.01 -0.01 -0.68 -1258.47 -0.83 No Ice 0.9 Dead+1.6 Wind 90 deg- 14.72 19.01 -0.01 -0.50 -1252.31 -0.82 No Ice 1.2 Dead+1.6 Wind 120 deg 19.62 16.46 9.55 631.67 -1089.92 -0.91 -No Ice 0.9 Dead+1.6 Wind 120 deg 14.72 16.46 9.55 628.80 -1084.58 -0.90 -No Ice 1.2 Dead+1.6 Wind 150 deg 19.62 9.50 16.55 1094.58 -629.43 -0.75 -No Ice 0.9 Dead+1.6 Wind 150 deg 14.72 9.50 16.55 1089.48 -626.30 -0.74 -No Ice 1.2 Dead+1.6 Wind 180 deg 19.62 -0.01 19.11 1264.00 -0.37 -0.39 -No Ice 0.9 Dead+1.6 Wind 180 deg 14.72 -0.01 19.11 1258.08 -0.28 -0.39 -No Ice 1.2 Dead+1.6 Wind 210 deg 19.62 -9.51 16.56 1094.55 628.70 0.08 -No Ice 0.9 Dead+1.6 Wind 210 deg 14.72 -9.51 16.56 1089.45 625.75 0.08 -No Ice 1.2 Dead+1.6 Wind 240 deg 19.62 -16.47 9.56 631.62 1089.22 0.53 -No Ice 0.9 Dead+1.6 Wind 240 deg 14.72 -16.47 9.56 628.75 1084.05 0.52 -No Ice 1.2 Dead+1.6 Wind 270 deg 19.62 -19.01 0.01 -0.75 1257.80 0.83 -No Ice 0.9 Dead+1.6 Wind 270 deg 14.72 -19.01 0.01 -0.56 1251.81 0.82 -No Ice 1.2 Dead+1.6 Wind 300 deg 19.62 -16.46 -9.55 -633.11 1089.26 0.91 -No Ice 0.9 Dead+1.6 Wind 300 deg 14.72 -16.46 -9.55 -629.87 1084.08 0.91 -No Ice 1.2 Dead+1.6 Wind 330 deg 19.62 -9.50 -16.55 -1096.01 628.76 0.75 -No Ice 0.9 Dead+1.6 Wind 330 deg 14.72 -9.50 -16.55 -1090.54 625.81 0.74 -No Ice 1.2 Dead+1.0 Ice+1.0 Temp 43.49 0.00 -0.00 -2.43 0.23 0.00 1.2 Dead+1.0 Wind 0 43.49 0.00 -2.19 -148.68 0.17 0.05 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 30 43.49 1.09 -1.90 -129.13 -72.63 0.01 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 60 43.49 1.89 -1.10 -75.64 -125.91 -0.04 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 90 43.49 2.18 -0.00 -2.56 -145.39 -0.08 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 120 43.49 1.89 1.10 70.54 -125.85 -0.09 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 150 43.49 1.09 1.90 124.07 -72.53 -0.09 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 180 43.49 -0.00 2.19 143.68 0.29 -0.05 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 210 43.49 -1.09 1.90 124.13 73.09 -0.01 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 240 43.49 -1.89 1.10 70.65 126.37 0.04 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 270 43.49 -2.18 0.00 -2.44 145.84 0.08 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 300 43.49 -1.89 -1.10 -75.54 126.30 0.09 deg+1.0 Ice+1.0 Temp 1.2 Dead+1.0 Wind 330 43.49 -1.09 -1.90 -129.07 72.98 0.09 . deg+1.0 Ice+1.0 Temp Dead+Wind 0 deg-Service 16.35 0.00 -4.45 -294.15 -0.27 0.09 Dead+Wind 30 deg-Service 16.35 2.21 -3.85 -254.82 -146.28 -0.02 Dead+Wind 60 deg-Service 16.35 3.83 -2.23 -147.37 -253.18 -0.12 Dead+Wind 90 deg-Service 16.35 4.43 -0.00 -0.59 -292.30 -0.19 Dead+Wind 120 deg- 16.35 3.83 2.22 146.19 -253.18 -0.21 Service Dead+Wind 150 deg- 16.35 2.21 3.85 253.64 -146.30 -0.17 Service tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CC/BU No 855864 Project Number CN4-226/6150003,Application 280246,Revision 0 Page 16 Load Vertical Shear, Shear Overturning Overturning Torque Combination Moment,M. Moment,M, K K K kip-ft kip-ft kip-ft Dead+Wind 180 deg- 16.35 -0.00 4.45 292.96 -0.28 -0.09 Service Dead+Wind 210 deg- 16.35 -2.21 3.85 253.63 145.73 0.02 Service Dead+Wind 240 deg- 16.35 -3.83 2.23 146.18 252.62 0.12 Service Dead+Wind 270 deg- 16.35 -4.43 0.00 -0.60 291.75 0.19 Service Dead+Wind 300 deg- 16.35 -3.83 -2.22 -147.38 252.63 0.21 Service Dead+Wind 330 deg- 16.35 -2.21 -3.85 -254.83 145.74 0.17 Service Solution Summary Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ %Error Comb. K K K K K K 1 0.00 -16.35 0.00 0.00 16.35 0.00 0.000% 2 0.01 -19.62 -19.11 -0.01 19.62 19.11 0.000% 3 0.01 -14.72 -19.11 -0.01 14.72 19.11 0.000% 4 9.51 -19.62 -16.56 -9.51 19.62 16.56 0.000% 5 9.51 -14.72 -16.56 -9.51 14.72 16.56 0.000% 6 16.47 -19.62 -9.56 -16.47 19.62 9.56 0.000% 7 16.47 -14.72 -9.56 -16.47 14.72 9.56 0.000% 8 19.01 -19.62 -0.01 -19.01 19.62 0.01 0.000% 9 19.01 -14.72 -0.01 -19.01 14.72 0.01 0.000% 10 16.46 -19.62 9.55 -16.46 19.62 -9.55 0.000% 11 16.46 -14.72 9.55 -16.46 14.72 -9.55 0.000% 12 9.50 -19.62 16.55 -9.50 19.62 -16.55 0.000% 13 9.50 -14.72 16.55 -9.50 14.72 -16.55 0.000% 14 -0.01 -19.62 19.11 0.01 19.62 -19.11 0.000% 15 -0.01 -14.72 19.11 0.01 14.72 -19.11 0.000% 16 -9.51 -19.62 16.56 9.51 19.62 -16.56 0.000% 17 -9.51 -14.72 16.56 9.51 14.72 -16.56 0.000% 18 -16.47 -19.62 9.56 16.47 19.62 -9.56 0.000% 19 -16.47 -14.72 9.56 16.47 14.72 -9.56 0.000% 20 -19.01 -19.62 0.01 19.01 19.62 -0.01 0.000% 21 -19.01 -14.72 0.01 19.01 14.72 -0.01 0.000% 22 -16.46 -19.62 -9.55 16.46 19.62 9.55 0.000% 23 -16.46 -14.72 -9.55 16.46 14.72 9.55 0.000% 24 -9.50 -19.62 -16.55 9.50 19.62 16.55 0.000% 25 -9.50 -14.72 -16.55 9.50 14.72 16.55 0.000% 26 0.00 -43.49 0.00 -0.00 43.49 0.00 0.000% 27 0.00 -43.49 -2.19 -0.00 43.49 2.19 0.000% 28 1.09 -43.49 -1.90 -1.09 43.49 1.90 0.000% 29 1.89 -43.49 -1.10 -1.89 43.49 1.10 0.000% 30 2.18 -43.49 -0.00 -2.18 43.49 0.00 0.000% 31 1.89 -43.49 1.10 -1.89 43.49 -1.10 0.000% 32 1.09 -43.49 1.90 -1.09 43.49 -1.90 0.000% 33 -0.00 -43.49 2.19 0.00 43.49 -2.19 0.000% 34 -1.09 -43.49 1.90 1.09 43.49 -1.90 0.000% 35 -1.89 -43.49 1.10 1.89 43.49 -1.10 0.000% . 36 -2.18 -43.49 0.00 2.18 43.49 -0.00 0.000% 37 -1.89 -43.49 -1.10 1.89 43.49 1.10 0.000% 38 -1.09 -43.49 -1.90 1.09 43.49 1.90 0.000% 39 0.00 -16.35 -4.45 -0.00 16.35 4.45 0.000% 40 2.21 -16.35 -3.85 -2.21 16.35 3.85 0.000% 41 3.83 -16.35 -2.23 -3.83 16.35 2.23 0.000% 42 4.43 -16.35 -0.00 -4.43 16.35 0.00 0.000% 43 3.83 -16.35 2.22 -3.83 16.35 -2.22 0.000% 44 2.21 -16.35 3.85 -2.21 16.35 -3.85 0.000% 45 -0.00 -16.35 4.45 0.00 16.35 -4.45 0.000% 46 -2.21 -16.35 3.85 2.21 16.35 -3.85 0.000% 47 -3.83 -16.35 2.23 3.83 16.35 -2.23 0.000% 48 -4.43 -16.35 0.00 4.43 16.35 -0.00 0.000% tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CC1 BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 17 Sum of Applied Forces Sum of Reactions Load PX PY PZ PX PY PZ %Error Comb. K K K K K K r 49 -3.83 -16.35 -2.22 3.83 16.35 2.22 0.000% 50 -2.21 -16.35 -3.85 2.21 16.35 3.85 0.000% Non-Linear Convergence Results Load Converged? Number Displacement Force Combination of Cycles Tolerance Tolerance 1 Yes 4 0.00000001 0.00000001 2 Yes 4 0.00000001 0.00005347 3 Yes 4 0.00000001 0.00003145 4 Yes 5 0.00000001 0.00003208 5 Yes 4 0.00000001 0.00080626 6 Yes 5 0.00000001 0.00003415 7 Yes 4 0.00000001 0.00085783 8 Yes 4 0.00000001 0.00016488 9 Yes 4 0.00000001 0.00009918 10 Yes 5 0.00000001 0.00003054 11 Yes 4 0.00000001 0.00076995 12 Yes 5 0.00000001 0.00003416 13 Yes 4 0.00000001 0.00085873 14 Yes 4 0.00000001 0.00005568 15 Yes 4 0.00000001 0.00003282 16 Yes 5 0.00000001 0.00003279 17 Yes 4 0.00000001 0.00082546 18 Yes 5 0.00000001 0.00003091 19 Yes 4 0.00000001 0.00077909 20 Yes 4 0.00000001 0.00016717 21 Yes 4 0.00000001 0.00010060 22 Yes 5 0.00000001 0.00003486 23 Yes 4 0.00000001 0.00087584 24 Yes 5 0.00000001 0.00003106 25 Yes 4 0.00000001 0.00078186 26 Yes 4 0.00000001 0.00001007 27 Yes 4 0.00000001 0.00024757 28 Yes 4 0.00000001 0.00025437 29 Yes 4 0.00000001 0.00025200 30 Yes 4 0.00000001 0.00023972 31 Yes 4 0.00000001 0.00024177 32 Yes 4 0.00000001 0.00023949 33 Yes 4 0.00000001 0.00023108 34 Yes 4 0.00000001 0.00023827 35 Yes 4 0.00000001 0.00024017 36 Yes 4 0.00000001 0.00023802 37 Yes 4 0.00000001 0.00025059 38 Yes 4 0.00000001 0.00025333 39 Yes 4 0.00000001 0.00000001 40 Yes 4 0.00000001 0.00002686 41 Yes 4 0.00000001 0.00003221 42 Yes 4 0.00000001 0.00001265 43 Yes 4 0.00000001 0.00002466 44 Yes 4 0.00000001 0.00003206 45 Yes 4 0.00000001 0.00000001 46 Yes 4 0.00000001 0.00002833 . 47 Yes 4 0.00000001 0.00002467 48 Yes 4 0.00000001 0.00001263 49 Yes 4 0.00000001 0.00003421 50 Yes 4 0.00000001 0.00002514 tnxTower Report-version 6.1.4.1 February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 18 Maximum Tower Deflections - Service Wind r Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° L1 78.5-49.33 6.388 39 0.8034 0.0028 L2 53-0 2.786 39 0.5049 0.0009 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 80.00 742-265 w/pipe mount 39 6.388 0.8034 0.0028 18058 60.00 XP18-80-0 w/pipe mount 39 3.648 0.5837 0.0013 4880 40.00 GPS A 39 1.587 0.3684 0.0003 4691 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. . L1 78.5-49.33 27.445 2 3.4437 0.0119 L2 53-0 11.982 2 2.1712 0.0037 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 80.00 742-265 w/pipe mount 2 27.445 3.4437 0.0119 4230 60.00 XP18-80-0 w/pipe mount 2 15.685 2.5078 0.0056 1142 40.00 GPS_A 2 6.833 1.5867 0.0013 1095 Compression Checks Pole Design Data Section Elevation Size L L„ Ki/r A P„ (1P, Ratio No. P ft ft ft in2 K K BPD L1 78.5-49.33 TP28.012x18.87x0.1875 29.17 0.00 0.0 15.874 -10.41 1054.59 0.010 . (1) 5 L2 49.33-0(2) TP43.1x26.4868x0.3125 53.00 0.00 0.0 42.439 -19.60 2861.65 0.007 8 Pole Bending Design Data Section Elevation Size M„x 4M„„ Ratio M y 4M,,,, Ratio No. M. M„y ft kip-ft kip-ft (wnx kip-ft kip-ft $M„r tnxTower Report-version 6.1.4.1 I February 03, 2015 78.5 Ft Monopole Tower Structural Analysis CCI BU No 855864 Project Number CN4-226/6150003,Application 280246, Revision 0 Page 19 Section Elevation Size Mux 4M„x Ratio Muy (I)My Ratio No. Mux Muy ft kip-ft kip-ft 1:,Mnx kip-ft kip-ft oMny r L1 78.5-49.33 TP28.012x18.87x0.1875 335.77 578.93 0.580 0.00 578.93 0.000 (1) L2 49.33-0(2) TP43.1x26.4868x0.3125 1265.43 2519.22 0.502 0.00 2519.22 0.000 Pole Shear Design Data Section Elevation Size Actual WV Ratio Actual 4T Ratio No. V Vu To T ft K K Oyu kip-ft kip-ft OT,, L1 78.5-49.33 TP28.012x18.87x0.1875 15.93 522.25 0.031 0.19 1159.28 0.000 (1) L2 49.33-0(2) TP43.1x26.4868x0.3125 19.13 1430.82 0.013 0.39 5044.59 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. Pu Mux M„ Vu Tu Stress Stress ft OP OM x OM,,,, 4V 4T Ratio Ratio L1 78.5-49.33 0.010 0.580 0.000 0.031 0.000 0.591 1.000 4.8.2 ✓ (1) V L2 49.33-0(2) 0.007 0.502 0.000 0.013 0.000 0.509 1.000 482 ✓ V Section Capacity Table I Section Elevation Component Size Critical P OPua„u % Pass No. ft Type Element K K Capacity Fail L1 78.5-49.33 Pole TP28.012x18.87x0.1875 1 -10.41 1054.59 59.1 Pass L2 49.33-0 Pole TP43.1x26.4868x0.3125 2 -19.60 2861.65 50.9 Pass Summary Pole(L1) 59.1 Pass RATING= 59.1 Pass J tnxTower Report-version 6.1.4.1 1 t APPENDIX B BASE LEVEL DRAWING tnxTower Report-version 6.1.4.1 (PROPOSED) (2)3/8'TO 80 FT LEVEL (4)3/4'TO 80 FT LEVEL (WSTALLfD-TO BE REMOVED) (3) 1/2'TO 80 FT LEVEL (4)3/4'TO 80 FT LEVEL (WSTALLFD) (1) 1/2'TO 40 FT LEVEL (6)7/8'TO 80 FT LEVEL (6) 1-5/8'TO 80 FT LEVEL MBING PEGS W/ SAFETY DUMB BUSINESS UNIT:856864 TOWER ID:C_BISELEVEL (PROPOSE (1) 1 J/; (INSTALLET (12) 7/8' APPENDIX C ADDITIONAL CALCULATIONS tnxTower Report-version 6.1.4.1 0, I Stiffened or Unstiffened, Ungrouted, Circular Base Plate -Any Rod Material LTIA Rev G Assumption: Clear space between bottom of leveling nut and top of concrete not exceeding(1)*(Rod Diameter) Site Data Reactions BU#: 855860 Mu: 1265 ft-kips Site Name: Schol/s Ferry Beef Bend Axial,Pu: 20 kips App#: 280246 Rev.0 Shear,Vu: 19 kips Pole Manufacturer:I Other I Eta Factor,n 0.5 TA G(Fig.4-4) Anchor Rod Data If No stiffeners,Criteria: 1 AISC LRFD <-Only Applcable to Unstiffened Cases Qty: 12 Diam: 2.25 in Rod Material: Other Anchor Rod Results Rigid Strength(Fu): 100 ksi Max Rod(Cu+Vu/n): 106.0 Kips AISC LRFD Yield(Fy): 75 ksi Allowable Axial,0*Fu*Anet: 260.0 Kips "Tn Bolt Circle: 50 in Anchor Rod Stress Ratio: 40.8% Pass Plate Data _— Diam: 56 in Base Plate Results Flexural Check Rigid Thick: 2.5 in Base Plate Stress: 13.0 ksi AISC LRFD Grade: 60 ksi Allowable Plate Stress: 54.0 ksi cp'Fy Single-Rod B-eff: 11.40 in Base Plate Stress Ratio: 24.2% Pass Y.L.Length: 25.35 Stiffener Data(Welding at both sides) n/a Config: 0 Stiffener Results Weld Type: Horizontal Weld: n/a Groove Depth: <–Disregard Vertical Weld: n/a Groove Angle: <–Disregard Plate Flex+Shear,fb/Fb+(fv/Fv)^2: n/a Fillet H.Weld: in Plate Tension+Shear,ft/Ft+(fv/Fv)^2: n/a Fillet V.Weld: in Plate Comp.(AISC Bracket): n/a Width: in Height: in Pole Results Thick: in Pole Punching Shear Check: n/a Notch: in Grade: ksi Weld str.: ksi Pole Data _ Diam: 43.1 in ° Thick: 0.3125 in Grade: 65 ksi ` #of Sides: 18 "0"IF Round Fu 80 ksi ` Reinf.Fillet Weld 0 "0"if None 0 c •0=none,1=every bolt,2=every 2 bolts,3=2 per bolt "'Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CClplate v2.0 Analysis Date:2/3/2015 (Bearing and Stability Checks) Tool for TIA Rev F or G -Application (MP, SST with unitbase) Monopole Base Reaction Forces Site Data TIA Revision: G <-Pull Down BU#: 855864 Factored DL Axial, PDu: 20 kips Site Name: Scholls Ferry Beef Bend Factored WL Axial, PWu: 0 kips App#: 280246 Rev. 0 Factored WL Shear,Vu: 19 kips Factored WL Moment, Mu: 1265 ft-kips Loads Alread Factored Load Factor Shaft Factored Loads For P(DL) 1.2 <----Disregard 1.00 1.2D+1.6W,Pu: 20 kips For P,V,and M 1.35 0.90 0.9D+1.6W,Pu: 15 kips (WL) <----Disregard Vu: 19 kips 1.00 Mu: 1265 ft-kips Pad &Pier Data Base PL Dist.Above Pier: 0 in 1.2D+1.6W Load Combination, Bearing Results: Pier Dist.Above Grade: 6 in (No Soil Wedges) 386 77 P1="1.2D+1.6W" Pad Bearing Depth, D: 15 ft [Reaction+Conc+Soil] (Kips) Pad Thickness,T: 2 ft Factored"1.6W"Overturning 1540.95 ft-kips Pad Width=Length, L: 13 ft Moment(MW-Msoil),M1 Pier Cross Section Shape: Round <--Pull Down Enter Pier Diameter: 5.33 ft Orthogonal Direction: Concrete Density: 150.0 pcf Pier Cross Section Area: 22.31 ft^2 eccl = M1/P1 = 3.98 ft Pier Height: 13.50 ft Orthogonal qu= 5.91 ksf Soil (above pad) Height: 13.00 ft qu/l)*qn Ratio= 49.27% Pass Soil Parameters Diagonal Direction: Unit Weight,y: 110.0 pcf Ultimate Bearing Capacity, qn: 16.00 ksf ecc2 = (0.707M1)/P1 = 2.82 ft Strength Reduct.factor, 4): 0.75 Diagonal qu= 7.13 ksf Angle of Friction,0: 28.0 degrees qu/4*qn Ratio= 59.40% Pass Undrained Shear Strength, Cu: 0.00 ksf Allowable Bearing:4)*qn: 12.00 ksf Run <--Press Upon Completing All Input Passive Pres. Coeff., Kp_ 2.77 Overturning Stability Check Forces/Moments due to Wind and Lateral Soil 0.9D+1.6W Load Combination,Bearing Results: Minimum of (cp*Ultimate Pad Passive Force,Vu): 19.0 kips Pad Force Location Above D: 0.98 ft (w/Soil Wedges) 402.85 P2="0.9D+1.6W" ()(Passive Pressure Moment): 18.55 ft-kips [Reaction+Conc+Soil] (Kips) Factored O.T. M(WL),"1.6W": 1559.5 ft-kips Factored OT(MW-Msoil), M1 1540.95 ft-kips Factored"1.6W"Overturning Moment(MW-Msoil)-0.9(M of 579.41 ft-kips Wedge+M of Cohesion),M2 Resistance due to Foundation Gravity Soil Wedge Projection grade,a: 6.91 ft Sum of Soil Wedges Wt: 125.30 kips Orthogonal ecc3= M2/P2 = 1.44 ft Soil Wedges ecc, K1: 8.53 ft Ortho Non Bearing Length,NBL= 2.88 ft Ftg+Soil above Pad wt: 305.6 kips Orthogonal qu= 3.44 ksf Unfactored(Total ftg-soil Wt): 430.94 kips Diagonal qu= 3.35 ksf 1.2D. No Soil Wedges. 386.77 kips 0.9D. With Soil Wedges 402.85 kips Max Reaction Moment(ft-kips)so that qu=cp*qn = 100% Capacity Ratin Resistance due to Cohesion (Vertical) Actual M: 1265.00 4)*(1/2*Cu)(Total Vert. Planes) 0.00 kips M Orthogonal: 3113.51 40.63% Pass Cohesion Force Eccentricity, K2 0.00 ft M Diagonal: 3002.95 42.13% Pass "Bearing/Stability Pier Square Pad"Tool, BSPSQP,Version 3.0- Effective 06/27/2011 Analysis Date: 2/3/2015