Specifications MAYES TESTING ENGINEERS, INC. Valley
Road
Suite 110
Lymwood,WA 98036
ph 425.742.9360
Project No. P14297 fax 425.745.1737
Project Spruce St Village
RECEIVEII Tacoma x
Address 8830 SW Spruce St Tigard, OR 10029S Tacoma
Permit No. MST2014-00164
Taxoma,WA98499
Bldg Dept. City of Tigard
ph 253.584.3720
MAO? 1 7 2015 fax 253.584.3707
Owner Anderson Homes r urn Portland Ofce
Architect Fowler Home & Design CITY OF'fl(;ARD 7911 NE 33rdDriw
Sui 190
Engineer Michael Brown lUILDING DIVISION Portland,nd,
OR 97211
Contractor Anderson Homes/Westland Industries ph503281.7515
fax 503281.7579
Record No. 003
Date 03/11/15
Weather Mostly Cloudy
Inspection Structural Steel/Welding
Sample(s) None
Provided continuous special inspection on the welding of Complete Joint Penetration groove welds
on the top and bottom beam flanges to the wide flange column at the garage door opening m oment
frame. Inspected joint fit-up, root passes, inter passes and completed weld profile per approved
plans and AWS D1.1-10 visual acceptance criteria.
To the best of our knowledge, all items inspected today are in conformance with approved plans
and specifications.
Inspector: Jim Lamberth
OBOA#417
Reviewed By:
./(1\4140.,,, , L.. 41-- ji-G(----
Jim Lamberth
Senior Project Manager
information in this report applies only to the actual items inspected or tested and shat not be reproduced except in full.without the approrel of Mayes Testing Engineers,Inc
Page 1 of 1