Loading...
Permit CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT 1 3 - COMMUNITY DEVELOPMENT Permit#: FPS2015-00033 Date Issued: 03/10/2015 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Parcel: 2S113BA00400 Jurisdiction: Tigard Site address: 7632 SW DURHAM RD 305 Project: Hi Tech Subdivision: ROSEWOOD ACRE TRACTS Lot: D Project Description: Add(3)fire sprinklers for new tenant Contractor: PATRIOT FIRE PROTECTION INC Owner: PORTLAND SW CENTER LLC 4708 NE MINNEHAHA ST BY FELTON PROPERTIES INC VANCOUVER,WA 98661 ATTN: FELTON, MATT 520 SW 6TH AVE, STE 610 PORTLAND, OR 97204 PHONE: 360-699-4403 PHONE: FAX: 360-699-4485 FEES Description Date Amount Specifics: Permit Fee-COM 03/09/2015 $56.47 12%State Surcharge-Building 03/09/2015 $6.78 Type of Use: COM Plan Review-Fire Life Safety-COM 03/09/2015 $22.59 Class of Work: ALT Type of Const: IIB Info Process/Archiving-Sm$0.50(up to 03/09/2015 $0.50 Occupancy Grp: B Height: ft 11x17) Stories: 3 Misc Administration Fee 03/09/2015 $5.00 Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Unknown Standpipe Required: Hazard: LT Density: .10 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $91.34 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $650.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: // ,, Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System MAR 5 2015 1 Ult OFFICE I SE()NIA City of Tigard ReC`1Ved lAger Permit No ,vSOW/�d 0033 • 13125 SW Hall Blvd.,Tigard,OR 9 Y OF TIGAitU Plan Review • Phone: 503.718.2439 Fax: 503.598.1*:I Date/B Other Perry ��Q��_�O •TI G A R 1) Inspection Line: 503.639.4175 BIJ 1 ING DIVISION Date Ready/By: lugs: H See Page 2 for Internet: www.tigard-or.gov Notified/Method: %76— Supplemental Information TYPE OF WORK REQUIRED DATA: 1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Pe fees*are based on the value of the work perfo. ed. lndicat- e value(rounded to the nearest dollar)o =11 ®Addition/alteration/replacement ❑()then. equipment, t aterials,labor,overhead,and the .••fit for the , E work indicate.on this application. CATEGORY OF CONSTRUCTION ❑ 1-and 2-family dwelling Commercial/industrial Valuation: $ ID Accessory building ❑Multi-family Number of bedroom ❑Master builder ['Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address 7632 SW Durham Road New dwelling are. quare feet City/State/ZIP: Tigard, OR 97224 Garage/cargo. area: squ• e feet Suite/bldg./apt.no.:03 1 3O7 Project name: Hi Tech T.I. Covere• ..rcharea: square - Cross street/directions to job site: SW 76th Ave De area: square feet • her structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Ad (3) sprinklers to accommodate new walls Valuation: $ 650 Existing building area: same square feet New building area: same square feet ® PROPERTY OWNER ❑ TENANT Number of stories: 3 Name: Felton Properties Type of construction: 23 Address: 520 SW 6th Ave, Suite 650 Occupancy groups: City/State/ZIP: Portland, OR 97204 Existing: B Phone:(503 )227 2433 ! kw ( 1 New: B 6 APPLICANT 1 ❑ CONTACT PERSON NOTICE Business name: Patriot Fire Protection, Inc All contractors and subcontractors are required to be Contact name: Ted Baker licensed with the Oregon Construction Contractors Board 4708 NE Minnehaha Street under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed.If the City/State/ZIP: Vancouver, WA 98661 applicant is exempt from licensing,the following reasons apply: Phone:(360) 699 4403 Fax::(360 ) 699 4485 F-mail: ted.baker @patriotfire.com CONTRA("I OR BUILDING PERMIT FEES* Business name: same as above (Please rejermjeeschedw/e Permit fee: Address: City/State/ZIP: State surcharge(12%of permit fee): • FLS plan review(40%of permit fee): Phone:( ) Fax:( ) (Due upon application submittal) CCB lie.: 70822 /21a,02/42 Total permit fees: Authorized signature: Amount received: This permit application expires if a permit is not obtained Print name: Ted Baker Date: 3-2-15 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. 1:\Bui Wing'PermitsWPS-PenmtApp_071514.doc 4404513T(1 1/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2-Supplemental Information Describe work to be done: 1.) Type of Work: 2.) .Addition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: ❑ New system Number of sprinkler heads: Number of alarm devices: Addition or P al 1-10 heads: Affidavit required and ❑ 1-5 devices: Affidavit required and , � Alteration ;,. (3)copies of sketch showing area (3)copies of sketch showing area to existing of work within building structure of work within building structure system ❑ 11+ heads: Plan review required and ❑ 6+ devices: Plan review required and (3)sets of plans. (3)sets of plans. Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ \\'et ❑ Dr\ Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square l.00tage: Permit I;ee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B& C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12% of permit fee): $ FLS Plan Review(40% ofpermit fee): $ TOTAL: $ \\patriotfire.Iocal\dfs\VAN Profiles\ted.baker\Downloads\FPS_PermitApp.doc 2 RECEIVEI giCity of Tigard MAR 9 2015 PermitNo.: �/�S�O/S— DOO_ 3 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1��Q������r A�r, Date Received: 3/9,/� Inspection Line: 503.639.4175 ITT v iw _ Internet www.tigard-or.gov BUILDING DIVISION By FIRE SPRINKLER AFFIDAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Hi Tech Project Name: Occupancy: B Job Address: 7632 SW Durham Road Type of Construction: 2B Suite: - " 'cS Contractor: Patriot Fire Protection Phone: 360 699 4403 Number of Proposed or Altered Heads -3 PE,z 7n' 3/945 ; Type: SSP Hazard: Light Density: •10 Ted Baker Oregon Construction Contractors Board No. 7oa22 I, certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits,beams, partitions, walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition,I understand the following is required: • Submit(3)copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: Date: 3-2-15 Print Name: Ted Baker I:\Building\Forms\FiresprinklerAffidavit 071514.docx Page 1 of 1 T;rszoi5-- RECEIVED `c o o II I MAR 9 2015 Hi Tech alli CITYOFTIGARU Tenant 'Ill II BUILDING DIVISION Improvement e AREA OF WORK ��"su& al A l' Irl 1 liii' lar�ini 1 ......m....... CI ■ 1,;\ 1 iiii KIP i li ,61, !IP44-110 E 139:61u add (3) SSPs V�_' ( . M4 ' 'EMI 1 li -- -I Ak Key Plan my OT TO SCALE PFP JOB # 32 - 12454 RECEIVED MAR 5 2015 CITY OFTIGARI) BUILDING DIVISION TRANSMITTAL DATE: 3-2-15 To : City of Tigard Building Dept. 13125 SW Hall Blvd Tigard, OR 97223 Att: Plans examiner From: Ted Baker re: Hi Tech T.I. fire sprinkler submittal ************************************************************************ Enclosed you will find (3) Area of work plan, (1) permit application and (1) TI Affidavit. Please feel free to call with any question. Thank you, Ted Baker OR CCB 70822 WA PATRIFP099CF FIRE ATRI�T TED BAKER-SERVICE PROJECT MANAGER FIR PROT€CTION INC. D 360.816.8714 C 360.831.5850 1 TED.BAKERaPATRIOTFIRE.COM 4708 NE MINNEHAHA STREET I VANCOUVER,WA 98661 I P 360.699.4403 I F 360.699.4485 Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 7632 SW DURHAM RD 305, TIGARD, OR, 97224 Commercial - Fire Protection System 999 Sprinkler final PASS - No C of O FPS2015-00033 Jeff Grove Violation Summary: Inspector Contractor