Loading...
Plans PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP -SCALE: NTS MODULE NOTES: TABLE OF CONTENTS 1. 9880W DC, 7800W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK) DIMENSIONS: 2. (38) REC SOLAR: REC260PE(BLK) MODULES WITH (1) ARRAY PITCH MAGNETIC TRUE 65.55"x 39.02"x 1.5" PAGE DESCRIPTION POWER-ONE: PVI-4.2-OUTD-S-US-A (240V) INVERTER AND ORIENTATION ORIENTATION 2. PORTRAIT: CLAMP 8.2"-16.4" FROM EDGE # (1) POWER-ONE: PVI-3.6-OUTD-S-US-A (240V) INVERTER. N, 3. LANDSCAPE: CLAMP 0"- 9.8" FROM EDGE 3. TWO STORY COMP SHINGLE ROOF AT 30° PITCH. AR-01 30° 164° 180° I7 PV-01 SITE PLAN 11607 SW Bull RACKING NOTES: _ 4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT Mountain Rd 1. SNAPNRACK SERIES 100 OR S100 UL LISTED; RUN PLACEMENT WITH CUSTOMER. PV-02 MECHANICAL 5. APN#: R0491505 FLUSH MOUNT L-FOOT. SEE PEN 001. 6. CONTACT: BOB ANNENBERG, (503) 805-4339 2. RAFTER AND PENETRATION LOCATIONS TO BE PV-03 ELECTRICAL 7. DESIGN CRITERIA: DETERMINED IN THE FIELD 7.1. SYSTEM WEIGHT: 3LBS/SQFT. 3. LAG SCREWS: 5/16" �S�I ��,„,// �� VV(a� MENT 11..._B S-1 STRUCTURAL DETAIL FEB 2 3 2015 CITY OF TIGARD gt III DING DIVISION SITE PLAN SCALE = 31128"= 1'0" (N) PV PRODUCTION METER (N) REC INSTALLED PV D1 -AR 01 SCALE: 1/8" = 1-0" , 35'-1" - -- (EXTERIOR WALL) LOAD CENTER ��� r 26-3" -'-1" 4i (E) MAIN PANEL (EXTERIOR WALL) r1'-2" (INTERIOR WALL) (N) INVERTERS WITH � (E) SERVICE ENTRANCE INTEGRATED DC DISCONNECTS —} (EXTERIOR WALL) (EXTERIOR WALL) y 22'-- ' 4'-5"I- �/'�\ PL -------- 6 /'\ 97% SW BULL MOUNTAIN ROAD PL 97% PL -------- PL r 1' _ _ \ 26'-2" Al A u 96% 97% \; 8'-9" • / \ �' a 2• Q_ • • ,' 97% A ` ° 97% CITY OF e-� a ', a FOR COD COMAMMCE App [iii 4 �� d - 46'-1" OTCs E 1 • �I F SEE SHEET S-1 FOR A INDICATES]]� UE t -' : _ 26 t ra. T ___�_____— PENETRATION LOCATIONS ##i° AT MARKEQ p�N L.E. IIT���� � D2 - ELEVATION DETAIL -SCALE: NTS Suit • Bp Dates I FS- / • • ) ..,.. ,; . . ' PL PL PL PL `` (N) CONDUIT RUN 31' 2" (IN ATTIC) (E) DRIVEWAY (N)ARRAY AR-01 - —1' Y 'Ier'' I • . (E) PROPERTY LINE . . t (E) RESIDENCE OFFICE COPY REC REC SOLAR, INC 3360sE2(ITH,PORT1 0 OR KLEIN REC PROJECT NUMBER: ANNENBERG RESIDENCE SITE PLAN REV: A OR CL#180464 e zoz DESIGNER: PHONE 503-766-4332 ANNENBERG 601R-430ANNE 14680 SW 117TH PLACE, TIGARD, OR 97224 PV-01 SQ (1 FAX 5°3-205-0748 DRAFTER: DI ( ) 7/24/2014 6107272993♦ (2) 5/16"-18 x 2-1/2" SS HCS (2) 5/16" SS SPLIT LOCK WASHER SNAPNRACK MODULE MID CLAMP RAIL SPLICE INSERT NOTES: • LAG BOLTS MUST EMBED IN ROOF . SNAPNRACK MODULE END CLAMP STRUCTURAL MEMBERS/RAFTERS • TORQUE ALL 5/16" HARDWARE TO 10 FT-LBS SNAPNRACK CHANNEL NUT �. (120 IN-LBS) TORQUE I_ v�'� , � • RAIL CAN MOUNT TO EITHER SIDE OF L-FOOT SNAPNRACK STANDARD RAIL RAIL SPLICE TOP•�' (UPSLOPE VS. DOWNSLOPE) '��� � o (2) 5/16" SS SPLIT • FOR UNEVEN ROOFS, USE 1" STANDOFF SHAFT o 1 0 LOCK WASHER SNAPNRACK RAIL 5/16"-18 x 1" SS HCS SPLICE ASSEMBLY SNAPNRACK FLASHED STEP 3: SECURE L-FOOT TO L-FOOT KIT STANDOFF BASE TO 5/16" SS SPLIT SECURE FLASHING AND LOCK WASHER 5/16"-18 x 3.5" SS HLS MOUNTING RAILS (MIN 2.5" EMBEDMENT TO STEP 2: SLIP FLASHING OVER SNAPNRACK L-FOOT RAFTERS) L-FOOT BASE 5/16" x 3/4" FLAT WASHER STEP 1: BOLT L-FOOT BASE TO SNAPNRACK CHANNEL NUT 5/16"-18 x 3/4" SS HCS ROOF WITH LAG BOLT SNAPNRACK STANDARD RAIL 5/16"-18 SS FLAT HEX NUT vi, �` 5/16" SS SPLIT LOCK WASHER SNAPNRACK L-FOOT BASE SEAL PENETRATION AND '0:4:� ROOF DECKING UNDER BASE 5/16".411111AA RAINBUSTER (OR 1111-"'v� '414111111111111111111111111 111"EQUIVALENT) SEALANT / (E) ROOF �1 SNAPNRACK DECKING �' COMPOSITION QED\NS1P"�P�,ON FLASHING GOMP\-E (E) RAFTER SNAPNRACK RACKING SYSTEM SERIES 100: L-FOOT MOUNTING DETAIL REC MI REC SOLAR, INC. OR CL#180464 87 3380SE20TH.PORTLANO,OR DESIGNER: KLEIN REC PROJECT NUMBER: ANNENBERG RESIDENCE REV:A PHONE 503-766-4332 202 MECHANICAL PV-02 SO �` FAX 503-205-0748 DRAFTER: DI ANNENBERG (601R-430ANNE) 14680 SW 117TH PLACE, TIGARD, OR 97224 7/24/2014 6197272093 LINE DIAGRAM: 120/240 VAC SYSTEM CHARACTERISTICS -INVERTER 1 SINGLE PHASE SERVICE PV MODULES POWER-ONE: SYSTEM SIZE 5200 W METER#: PVI-4.2-OUTD-S-US-A (240V) REC SOLAR. REC260PE(BLK) < © PGE IN23153664 4200 WATT INVERTER JUNCTION BOX ±�// (1) STRING OF (10) MODULES SYSTEM OPEN CIRCUIT VOLTAGE 412 V 2 OR EQUIVALENT 1 UTILITY _ o--e----o SYSTEM OPERATING VOLTAGE 307 V GRID `r 1 I MAX ALLOWABLE DC VOLTAGE 600 V i EXISTING - o- �∎a j 1� PV MODULES C SYSTEM OPERATING CURRENT 17 A 320A MAIN REC SOLAR: REC260PE(BLK) p - / SYSTEM SHORT CIRCUIT CURRENT 22.53 A BREAKER DUAL MPPT TRACKERS STRING *hj// (10) MODULES COMBINER & LOAD RATED DC `- (1) STRING OF (10) MODULES LABEL PLACEMENT:AC BREAKER NEW 100A PV DISCONNECT AND ACFI (INSIDE OR FRONT OF PANEL) EXISTING LOAD CENTER < 400A MAIN *NO LOADS TO PV MODULES SYSTEM CHARACTERISTICS -INVERTER 2 PANEL DEDICATED PV BE INSTALLED' POWER-ONE: REC SOLAR: REC260PE(BLK) FACILITY KWH METER PVI-3.6-OUTD-S-US-A (240V) , 1// SYSTEM SIZE 4680 W LOADS 3600 WATT INVERTER JUNCTION BOX - ( (9) MODULES --4 r 4 3 2 OR EQUIVALENT 1 (1) STRING OF (9) MODULES SYSTEM OPEN CIRCUIT VOLTAGE 371 V o- 410 s o-e�o I (\i SYSTEM OPERATING VOLTAGE 276.3 V FACILITY 3 o ego I PV MODULES MAX ALLOWABLE DC VOLTAGE 600 V 50A PV GROUND 250V METER SOCKET 25A BREAKER (A) // REC SOLAR: REC260PE(BLK) SYSTEM OPERATING CURRENT 17 A BREAKER AT 125A CONTINUOUS & 20A BREAKER (B) DUAL MPPT TRACKERS STRING - +w / (9) MODULES OPPOSITE END 240V METER COMBINER & LOAD RATED DC (1) STRING OF (9) MODULES SYSTEM SHORT CIRCUIT CURRENT 22.53 A OF BUSBAR 200A, FORM 2S DISCONNECT AND AFC! LABEL PLACEMENT:AC BREAKER (INSIDE OR FRONT OF PANEL) NOTES TO INSTALLER: CONDUIT SCHEDULE SIGNAGE: • WARNING 1. 378 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. ADD 50 AMP PV BREAKER TO MAIN PANEL. 'WARNING-Dual Power Sources 1 ELECTRIC SHOCK HAZARD , 3. FIT METER BASES SHOULD BE WIRED AS FOLLOWS: UTILITY SOURCE TO - # CONDUIT CONDUCTOR NEUTRAL GROUND Second source 15 photovoltaic system J DO NOT TOUCH TERMINALS LABEL PLACEMENT:MAIN PANEL TERMINALS ON BOTH LINE AND TOP LUGS, PV SOURCE TO BOTTOM LUGS. 1 NONE (4) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER NEAR METER LOAD SIDES MAY BE ENERGIZED WARNING IN THE OPEN POSITION 2 3/4" EMT OR EQUIV. (4) 10 AWG PV WIRE NONE (1) 6 AWG THHN/THWN-2 aEra.,EUTR1TCONNECTION 00 O DC VOLTAGE IS ALWAYS PRESENT • LABEL PLACEMENT:AC DISCONNECT, WHEN SOLAR MODULES 3 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 COMBINER BOX,INVERTER ARE EXPOSED TO SUNLIGHT 4 3/4" EMT OR EQUIV. (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 �NO�se servliceableperis n ee rd DC DISCONNECTS PLACEMENT: ON EMTST ( ) ( ) Gnntact author ced servicer for assstan DC DISCONNECTS LABEL PLACEMENT:AC DISCONNECT. WARNING COMBINER BOX,INVERTER Voltage Drop AC Voltage Drop DC ELECTRICAL NOTES: CAUTION:SOLAR ELECTRIC ELECTRIC SHOCK HAZARD 1. PHOTOVOLTAIC SYSTEM WILL Run Name Inverter to Main Panel Run Name Modules to Inverter SYSTEM CONNECTED J IFMALLY GROUNDED FAULT IS INDICATED LABEL PLACEMENT" NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED COMPLY WITH 2011 NEC. Select Material Cu Select Material Cu CONDUIT.JUNCTION BOXES 2. ELECTRICAL SYSTEM GROUNDING PHOTOVOLTAIC POWER LABEL PLACEMENT: Select Wire Size 8 Select Wire Size 10 SOURCE INVERTER WILL COMPLY WITH 2011 NEC. . 3. PHOTOVOLTAIC SYSTEM IS Select Conduit Type EMT Select Conduit Type EMT LABEL PLACEMENT: CONDUIT.JUNCTION BOXES WARNING UNGROUNDED. NO CONDUCTORS Select Voltage&Phase 240 1-phase Select voltage&Phase DC (r ELECTRIC SHOCK HAZARD ARE SOLIDLY GROUNDED IN THE DC Voltage(Use DC Voltage(Use string l DO NOT TOUCH TERMINALS INVERTER. SYSTEM COMPLIES string Vmp,otherwise Vmp,otherwise leave LABEL PLACEMENT: TERMINALS ON BOTH LINE AND WITH 690.35. MODULE CHARACTERISTICS leave blank for AC) blank for AC) 307 ALL DISCONNECTS LOAD SIDES MAY BE ENERGIZED Enter Distance to Load IN THE OPEN POSITION 4. MODULES CONFORM TO AND ARE (ft) 15 Enter Distance to Load(ft) 85 LABEL PLACEMENT: LISTED UNDER UL 1703. REC SOLAR: REC260PE(BLK) 260 W Enter Load(Amps) 17.19 Enter Load (Amps) 15 AC DISCONNECTS 5. INVERTER CONFORMS TO AND IS OPEN CIRCUIT VOLTAGE 37.8 V OUTPUTS OUTPUTS LISTED UNDER UL 1741. voltage Drop(Volts) 0.40 Voltage Drop(Volts) 1.99 6. ARRAY DC CONDUCTORS ARE OPEN CIRCUIT VOLTAGE: (690.7) 41.1 V WARNING SIZED FOR DERATED CURRENT. ei0 Voltage Drop p.17 %Voltage Drop 0.83 • 9.01 AMPS MODULE SHORT MAX POWER VOLTAGE 30.7 V VARIABLES VARIABLES ELECTRIC SHOCK HAZARD CIRCUIT CURRENT, SHORT CIRCUIT CURRENT 9.01 A Phase Factor 2 Phase Factor 2 THE DC CONDUCTORS OF THIS - PHOTOVOLTAIC SYSTEM ARE 14.07 AMPS DERATED SHORT K 12.9 K 12.9 UNGROUNDED AND MAY BE ENERGIZED CIRCUIT CIRCUIT(690.8 (a) &690.8 SHORT CIRCUIT CURRENT (690.8(A)(1)) 11.26 A Q-Factor 1 Q-Factor _ 1 , (b)) Circular Mils 16510 Circular Mils 16510 JUNCTION BOXES,COMBINER BOXES, DISCONNECTS REC REC SOLAR, INC 3380SE20TH PORTLAND,OR KLEIN REC PROJECT NUMBER: ANNENBERG RESIDENCE REV: A OR CL#180464 SOLAR, 97202 DESIGNER: PHONE 503-766-4332 ELECTRICAL PV-03 CEO �` FAX503-205-0748 ANNENBERG 601R-430ANNE 14680 SW 117TH PLACE, TIGARD, OR 97224 7/24/2014 6197272993 DRAFTER: DI ( )