Loading...
Permit CITY OF TIGARD MASTER PERMIT 11 COMMUNITY DEVELOPMENT Permit#: MST2015-00019 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/24/2015 Parcel: 25111 BB00300 Jurisdiction: Tigard Site address: 14085 SW 100TH AVE Subdivision: TIGARDVILLE HEIGHTS Lot: 11 Project: Petersen Project Description: Add to existing solar photovoltaic system BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $0.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines. 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Tvoes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O SvcFdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: PETERSEN,DAVID DYNAMIC POWER INNOVATION LLC Required Items and Reports(Conditions) 14085 SW 100TH AVE 236 SE BAKER STREET TIGARD,OR 97224 MCMINNVILLE,OR 97128 PHONE: 503-998-2105 PHONE: 503-857-0416 FAX: Total Fees: $321.88 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to folk. le rules adopted by the Oregon Utility Notifica on Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You r- obtai . copy o'R1e.oles or direct questions to OUNC by ca 5 .23 . 987 or 1.800.332.2344. Issued By: ,e-i�t1010- •e ittee Signature: i..(l- 41111.4 .3.639.4175 by 7:00 a.m.for the next available inspectio d This permit card shall be kept in a conspicuous place on the job site until comp) t' n of the oject. Approved plans are required on the job site at the time of each inspection. Building Permit Applicatian Residential FOR OFFICE USE ONLY City of Tigard FEB 10 2015 Receive4-zAT Permit No.: iti 5- ,d • 41 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Revie�' lig Phone: 503.718.2439 Fax: 503.411> l OF TIGARD DateB : inEgnI/, •her Permit - TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION Date Rea. :" ll Juris ® See Page 2 for Internet: www.tigard-or.gov Notified/Method:t-/i21' l� _ Supplemental Information 1) i Ito{ vGN TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® I-and 2-family dwelling ❑Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:14085 SW 100"'Ave New dwelling area: square feet City/State/ZIP:Tigard,Or 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Petersen Solar Covered porch area: square feet Cross street/directions to job site:SW McDonald St/South on Hwy 99W,Left Deck area: square feet on SW McDonald St..Right on SW 100'"Ave Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.:300 Permit fees*are based on the value of the work performed. Tax map/parcel no.:2S111 BB00300 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Install PV array on roof Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Dave Petersen Type of construction: Address: 14085 SW 100a Ave Occupancy groups: City/State/ZIP:Tigard,Or 97224 Existing: Phone:(503)998-2105 Fax:( ) New: ® APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name: Dyanmic Power Innovation (Please refer ln fee schedule) Structural plan review fee(or deposit): Contact name:Josh Kopczynski Address:236 SE Baker St FLS plan review fee(if applicable): Total fees due upon application: City/State/ZIP:McMinnville,Or 97128 Phone:(503)857-0416 Fax::( ) Amount received: ____.6)----' E-mail:dee @dpisolar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:Dyanmic Power Innovation Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:236 SE Baker St Solar Installation Specialty Code checklist. City/State/ZIP:McMinnville,Or 97128 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)857-0416 Fax:( 1 State surcharge(12%of permit fee): $21.60 CCB lic.: 185494 Total fee due upon application: $201.60 This permit signature: ermit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Josh Kopczy s Date: 1-22-15 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-46131(11/02/COM/WEB) gs• - -4Electrica1 Permit Application I„I:r■1 1 1(7 i SI ()NI City of Tigard EIVE® �' ` ♦ f ' Permit bra '9. (/e,•5 (XXj/ - 13125 SW Hail Blvd.Tiger Plan Review • a Phone- 503 718.2439 Fur 503.595 1960 Oho Paint , I Ic_^I ■ Inspection Line: 503.6394!75 FEB 1 0 2015 - --- -- Ise t,,,,:�. Iniema: wow Iigard-or a pparasnrsal Mbaameins F❑ .--- _ l ' PLAN REVIEW New construction ®A,Y6Ef QkG und TI t GARD Please ched all the apply twbmn 2 sets of plans aliens ehedced below) 1 0 Demolition Other: 0 Ssviree a feeder 400 amps or mots 0 lturldmr over three slate, when the available faith current ❑Marinas and hnarcards CATEGORY OF CONSTRUCTION exceeds 40,000 snits at I so vnhs a ❑I mating hurldrnrr less to pound t exceeds 14,000 ❑('ummerctal-user KUllnrrl I-and 2-family dwelling ❑Commercial/industrial 0 Accessory building r ❑Mtllt-family amps ro.all nrtrt muaNartgn txnldtngs y __ 0 Master builder ❑Other: OFire pump ❑ImtaIlatu r of 1 so 1 vA a JOS lif1E INFORMATION AND LOCATION O Emergency system big separately derived system .. __ �_ 1: OAddition of rrw moor load of ❑"A "t.."1-]' `I-]°. fob no. I Job site address:14085 SW 100"Ave IoolfP«mere rrcrgtanty —--^ O Six a more residential anal. ❑Recreational RN*parks CitylStatc/ZIP:T i p r d,Or 9 7 2 2 4 O Heath-cart facilnres 0 simply whom ter aame nor --_ O wsardan locabotn 600 volts nomad Suite/bldg./am.no: 1 Project nurse:Peteraea Solar - - __ -~ 0 pumice or feeder 600 amps a more PEE SCHEDULE Cross street/direaiats to job site:Hwy 99W Saatl,go IsR is SW McDaaald St reddeadN ■_ �.1 r� ?wl 1 • p rigid an SW 1006 Ave — - s11a taalMy jai laelydes attached germs Subdivision I Lot no.:300 1,000 aq R or less Ba i/ '4 Tex map/parcel no.:2S1118W0.i00 ------ Ea add'!sots ft or Paton 7392 t Ude I9EStalwIiopi OF WORK (with energy,residential 2 1 Limited energy.multi-family 9990 2 Install Inverters,disconnect with conduit and wire required for pv array. resldantat(with above so ft) _Services or feeders instaltatdor,ekeratlay aad/or relocation ® "Y OWNER -- 1 O TENANT ion amps or Ices loo 70 - 2 Name:Dave Petersen 201 amps to 400 an 133 56 2 401 amps to 600 amps 200.34 2 — Address:14085 SW 1006 Ave 601 maps to I,000 amps _- 2Address: - - Over 1.000 amps a volts 55226 _ 2 City/State/Z1P:Tigard,Or 97224 - ' Temporary services or feedersinmillatsa,*Wraiths,asd/ar Phone:(S03)998-2105 I Fa -( ) rdeadisa _-- 1 200 imps at less Sit 36 I Owner iestallation:This installation is being made on property that 1 own which is not 201 amps to 400 maps 12508 2 intended for sale.lease.rent,or exchange.according to ORS 447.449,670.and 701. ioI snips to 599 a> 16831 2 Owner signature- _ Dale: - - - _� -- Broach circuits-any,ageraMaa.or er�easleusler lard ® APl1.ICAN 0 CONTACT PERRON ' A Fee for branch circuits with 1 above service or feeder fee. 742 2 Business lame:Dynastic Power laaovatioa each branch armpit A Fee for branch circuits withow 'Contact name:Jtti Kopezyuski service or feeder fee,first — barldl Uralic I S6 IS 2 _+ — Address:237 SE Baker St Each add't branch circuit 742 2 1 CitylStateRlP:MtM inRVi■e,Or 97121 — lllisedlaaeossjaervice or reeler sot indrdcd) Fsch trwaufidmod or modular I 6784 2 t Phone:(503)857-0416 Fmt::( ) �dwetling saes=Whir feeder Reconnect Italy I 67 E4 _ 2 E-mail:dee(dpisolar.eeru Primp or irrigation circle 6764 _ 2 CONTRACTOR Siam err aiding lighting 6784 2 Business name:Fitzpatrick Electric Signal earwigs)a liniled<nergy See i pearl alteration.or mansion _ .. Pale 2 2 --I- r I hr MO i 662S/hr Address:PO Rex 83129 _- tl"PK' war a8aaraMe at the ar ' Cit /StatciZ1P:Portioned,Or 97283 lamm anion ti he Hint - 6625/hr f Phone:(SO)209-4191 Fax:( ) i tadentrW plant 41 hr mad n Illhr - - - -- • Inspections for which no fee is CCB Lic.: 173339 Electrical drier: C235 1 Suprv.Lie.: 5216$ I specifically hired I tr min) 90 hr_ ELECTRICAL 'war MS ' Suprv.Electrician signature,required: �� /-r rr/I4 r�(Cr' 1 I Subtotal: Print name: Todd Fitzpatrick Datc:,2- r- / 5 1, ! ____ Plan rtetriesr 125%trf pensit ra): -, -L-- (12%arm*foe): Authorized simonise -42,j l 7setCr TOTAL PERMIT FEE: S _ -- ""repo f-4 1.•Ett,!'TetCer Dale: Y ilfs4aarrtY dogsi waa�I Ira ospssd scomga mA.whr.oar Prise nlhale: � ' Dave: � �j,,,r_ dogs artist ass Ira�a w�er- t -- • honk.of slams algal per poem 11raldrwVten..WEU_t4rn+AM EAR[EREIrs Rea IWOWOOS weatsiiIISi O/r'f! 1 .i Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined ... $75.00 Description I Qty. I Fee I Total I Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 1 100.70 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 ❑ Burglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301.04 2 n Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with 552.26 2 OAR 918-309-0040) n H• eating, Ventilation and Air Conditioning System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 ® Each additional inspection over allowable in any of the above: Other: PV Each additional inspection is charged at an hourly(1 hr min) 66.25/hr Inspections for which no fee is 90.00/hr specifically listed('h hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fee): State surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 nAudio and Stereo Systems days after it has been accepted as complete. Number of inspections allowed per permit. n Boiler Controls ❑ Clock Systems n D• ata Telecommunication Installation n Fire Alarm Installation ❑ H• VAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls n Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermitApp_ELR_ERE.doe Rev 05/21/2013 1 ' RECEIVEP !AI • City of Tigard FEB 10 2015 Building Division CITY OFTIGAitll • 13125 SW Hall Blvd,Tigard,OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 TI G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14085 SW 100th Ave City: Tigard, Or Zip: 97224 Owner's Name: Dave Petersen Date: 1-22-15 Contractor's Name: Dynamic Power Innovation CCB #: 185494 Design Parameters of the Property/Structure If"Yes",does not Flood Hazard Is the installation o Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure ® Yes If"Yes",qualifies for Wind Exposure "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? 111 If"Yes",qualifies for • structures other than Yes the prescriptive path. above ❑ No 1 I:Building/Forms/PhotoVoltaic-Checklist.docx Is the construction CE material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction El No the prescriptive path. as"conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ® If"Yes",qualifies for Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes",qualifies for with Section 305.4(3)of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted ® Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof No framing or blockin ❑ the prescriptive path. to the roof g g directly? 2 I:Building/Forms/PhotoVoltaic-Checklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ® If"Yes",qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal anels If the width of the panel P Width of roofing is less than 18 inches, panels? 18 inches or less inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes",qualifies for fastener? El Yes the prescriptive path. I No Is the roof decking of WSP min. 'A"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. El No 3 (:Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Solar World Model Number: SW270 Listing Agency: UL 4 1:Bui ld ing/Forms/PhotoVoltaic-Checkl ist.docx