Loading...
Plans PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-SCALE: NTS MODULE NOTES: TABLE OF CONTENTS 1. 3640W DC, 3300W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK) DIMENSIONS: 2. (14) REC SOLAR: REC260PE(BLK) MODULES WITH (1)ABB: MAGNETIC TRUE 65.55"x 39.02"x 1.5" PAGE ARRAY PITCH �� f.t.,, .�,t: , �� # DESCRIPTION PVI-3.0-OUTD-S-US-A(240V) INVERTER. ORIENTATION ORIENTATION , ; ,_, _ 2. PORTRAIT: CLAMP 8.2"-16.4"FROM EDGE 3. TWO STORY COMP SHINGLE ROOF AT 34°PITCH. 3. LANDSCAPE: CLAMP 0"-9.8"FROM EDGE 4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT AR-01 34° 164° 180° PV-01 SITE PLAN&MECHANICAL TES: 1 RUN STRU T WITH CUSTOMER. .. 1. NRAOCK SERIES 100 OR S100 UL LISTED; PV-I[�ECE V TIDAL 5. ROOF STRUCTURE: 2X4 PRE FABRICATED TRUSSES 24"OC. FLUSH MOUNT L-FOOT. SEE PEN D01. , 6. APN#:2S111DA15200 2. LAG SCREWS: 5/16"X 3.5": 2.5" MIN EMBEDMENT 7. CONTACT: WILLY LIAG, 503-317-9798 ;:i'._ , Sw Brien r, r 3. RAFTER AND PENETRATION LOCATIONS TO BE FEB 2 2015 8. DESIGN CRITERIA: DETERMINED IN THE FIELD. 8.1. SYSTEM WEIGHT: 3LBS/SQFT. 4. INSTALLER TO VERIFY RAFTER SIZE, Cii Y OF' I , 8.2. EFFECTIVE WIND SPEED: 95 MPH 3-SEC GUST. AND UNSUPPORTED SPANS AND NOTIFY E.O.R 8.3. EFFECTIVE SNOW LOAD:25 LB/SQR FT. 44..._ OF ANY DISCREPANCIES BEFORE PROCEEDING. BUIL DING DIVISION "' g.7' Y SW AvC+f P SITE PLAN -SCALE=1116"= 1' f∎ D1 -AR-01 -SCALE: 1/8"= 1'-0" li - r ��r (N) SUN RUN METER • INDICATES TSRF VALUE AT MARKED LOCATION (INTERIOR WALL) (E) DRIVEWAY (N) INVERTER WITH —6' 10" 13'-2" 11' INTEGRATED DC DISCONNECT (E) MAIN PANEL (INTERIOR WALL) (INTERIOR WALL) I ■ SW PIPPEN LN { _ 2'-3" FL PL n --. ■a a *1a 99% I _ % 94% (E) RESIDENCE 4'TYP - _, \ a a a 116d4,),,--° —e- _099_.%• _a — >-- -e— a 4 • 10'-11" %I 4 '0 o — o— s— —e- —0— e— — C 8._9' " 9-- O , }} a a 9 6— b—4'---t-- —9 o— 9-- —e Q • a L 23' a (E) SKYLIGHT (E) SERVICE ENTRANCE T 28-4 CITY Coil TIGARD (EXTERIOR WALL) 0 REVIEWED FOR CODE COMPLIANCE Approved: [i 4 OTC: [ T 24( • Aaai rte► it�'11 12" FIRE SETBACKS a 6 By: - mall Dates 4` 7 26'-7" V' t • - . PL PL 20' 20\\— OFFICE COPY • (E) PROPERTY LINE ROOF AREA: 1801 SQ.FT. ARRAY AREA: 238 SQ.FT. (N)ARRAY AR-01 COVERAGE: 13% SUNRUN,INC. 3360SE20TH,PORTLAND,OR97202 REV:A sunrun OR CL#180464 PHONE 503.766.4332 DESIGNER: F. JAVIDKIA SUNRUN PROJECT NUMBER: LIAG RESIDENCE SITE PLAN & PV 01 FAX 503.205.0748 LIAG (601 R-900LIAN) 8900 SW PIPPEN LN., PORTLAND, OR 97224-5238 MECHANICAL 1/14/2015 o DRAFTER: DV LINE DIAGRAM: 120/240 VAC SINGLE PHASE SERVICE METER G I PGE 24522 2931 UTILITY GRID b EXISTING C200A MAIN p BREAKER EXISTING < . 200A MAIN ABB: PVI-3.0-OUTD-S-US-A JUNCTION BOX FACILITY PANEL SUN RUN (240V) 3000 WATT INVERTER MIN RATED NEMA3R METER (OR EQUIVALENT) LOADS ' PV MODULES .r �2 �1 / 3 3 _ G--e�o / REC SOLAR: REC260PE(BLK) �� —0 —� +� / (14) MODULES 0 ono (1) STRING OF (14) MODULES FACILITY 20A PV GROUND 250V METER SOCKET DUAL MPPT TRACKERS STRING BREAKER AT 125A CONTINUOUS & COMBINER & LOAD RATED DC OPPOSITE END 240V METER DISCONNECT AND AFCI OF BUSBAR 200A, FORM 25 NOTES TO INSTALLER: CONDUIT SCHEDULE SIGNAGE: • WARNING 1. 529 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. REPLACE (2) EXISTING 15A 2P BREAKERS WITH (1) NEW 15/20/15A 1-2-1P # CONDUIT CONDUCTOR NEUTRAL GROUND WARNING-Dual Power Sources Secondsourceisphotovoltaicsystem ELECTRIC SHOCK HAZARD QAUD BREAKER. CONNECT PV TO THE NEW 20A PORTION OF QAUD. . DO NOTTOUC-1 TERMINALS LABEL PLACEMENT:MAIN PANEL TERMINALS ON BOTH LINE AND 1 NONE (2) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER NEAR METER LOAD SIDES MAY BE ENERGIZED . - WARNING IN THE OPEN POSITION 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 „ „s ,,, lvE,C„wgE ,O„ „r DC VOLTAGE IS ALWAYS PRESENT LABEL PLACEMENT:AC DISCONNECT, WHEN SOLAR MODULES 3 3/4” EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 COMBINER BOX,INVERTER ARE EXPOSED TO SUNLIGHT WARNING-Electnc Shock Hazard_ LABEL PLACEMENT: No user serviceable parts inside r DC DISCONNECTS Contact authorized servicer for assistance LABEL PLACEMENT:AC DISCONNECT, WARNING COMBINER BOX,INVERTER ELECTRICAL NOTES: CAUTION:SOLAR ELECTRIC ELECTRIC SHOCK HAZARD SYSTEM CONNECTED IF A GROUND FAULT IS INDICATED 1. PHOTOVOLTAIC SYSTEM WILL LABEL PLACEMENT NORMALLY GROUNDED CONDUCTORS COMPLY WITH 2011 NEC. CONDUIT.JUNCTION BOXES MAY BE UNGROUNDED AND ENERGIZED 2. ELECTRICAL SYSTEM GROUNDING PHOTOVOLTAIC POWER ' LABEL PLACEMENT: WILL COMPLY WITH 2011 NEC. SOURCE NVERTER 3. PHOTOVOLTAIC SYSTEM IS COND PLACEMENT CONDUIT,JUNCTION BOXES WARNING UNGROUNDED. NO CONDUCTORS ( 1 ELECTRIC SHOCK HAZARD ARE SOLIDLY GROUNDED IN THE l J DO NOT TOUCH TERMINALS INVERTER. SYSTEM COMPLIES LABEL PLACEMENT: TERMINALS ON BOTH LINE AND ALL DISCONNECTS LOAD SIDES MAY BE ENERGIZED WITH 690.35. MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS -INVERTER 1 IN THE OPEN POSITION 4. MODULES CONFORM TO AND ARE ' LABEL PLACEMENT: LISTED UNDER UL 1703. REC SOLAR: REC260PE(BLK) 260 W SYSTEM SIZE 3640 W AC DISCONNECTS 5. INVERTER CONFORMS TO AND IS OPEN CIRCUIT VOLTAGE 37.8 V SYSTEM OPEN CIRCUIT VOLTAGE 576 V WARNING LISTED UNDER UL 1741. - — 6. ARRAY DC CONDUCTORS ARE OPEN CIRCUIT VOLTAGE: (690.7) 41.1 V SYSTEM OPERATING VOLTAGE 429.8 V ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS SIZED FOR DERATED CURRENT. MAX POWER VOLTAGE 30.7 V MAX ALLOWABLE DC VOLTAGE 600 V PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED 9.01 AMPS MODULE SHORT . CIRCUIT CURRENT. SHORT CIRCUIT CURRENT 9.01 A SYSTEM OPERATING CURRENT 8.5 A LABEL PLACEMENT. 14.07 AMPS DERATED SHORT SHORT CIRCUIT CURRENT (690.8(A)(1)) 11.26 A SYSTEM SHORT CIRCUIT CURRENT 11.26 A JUNCTION I DISCONNECTS COMBINER BOXES, CIRCUIT CIRCUIT(690.8 (a) &690.8 (b)). LABEL PLACEMENT:AC BREAKER (INSIDE OR FRONT OF PANEL) SUNRUN,INC. 3380 S E 20TH.PORTLAND.OR 97202 DESIGNER: sunrun OR CL#180464 PHONE 503 F JAVIDKIA SUNRUN PROJECT NUMBER: LIAG RESIDENCE REV: A FAX 503 DRAFTER: DV LIAG (601 R-900LIAN) 8900 SW PIPPEN LN., PORTLAND, OR 97224-5238 ELECTRICAL PV-02 1/14/2015 REVISION: NOTES: , - 5/16" LAG BOLTS MUST EMBED 2.5" INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT - TORQUE ALL 5/16" HARDWARE TO ON TOP OF FLASHING - - SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT . COMPOSITION L FOOT - SILVER S.S. 10-16 FT-LBS CAN BE MOUNTED IN 5 S.S. FLANGE NUT - BLACK S.S. 7-9 FT-LBS STEP 2: SLIP FLASHING OVER ANY ORIENTATION - RAILS CAN MOUNT TO EITHER SIDE L FOOT BASE AND UNDER ROW 35 X 1" (OR 1.25") OF L FOOT (UPSLOPE VS DOWNSLOPE) OF SHINGLES ABOVE SNAPNRACK n, S.S. BOLT AND 1\ CHANNEL NUT SPLIT WASHER V ��� % ‘ '' / �" S.S. LAG SCREW \ ��'' WITH FLAT WASHER SNAPNRACK ��j 2.5" MINIMUM EMBEDMENT ........ ----P------:91111111111°1111111111111111111111111111111.11.-- STANDARD RAIL IS STANDARD SNAPNRACK COMPOSITION ROOF FLASHING ._.7 STEP 1: BOLT L FOOT BASE TO ROOF WITH LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. )7//' ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT \••••• RAILS CAN BE LEVELED UP TO 3" USING iat _ __ __, ______- UP TO TWO LEVELING SPACERS AS SHOWN IN "SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION RAFTER TYP. SnMAINSTREAM (//�\\���I^��`�\\\\\ ///�\�///���/�7w ENERGY CORP. DESIGNER: G McPheeters _ SCALE: DNS PART NUMBER: DESCRIPTION: REV \\ JI(��)J)��\l Jlll Ifll 75`ER°HONE(805 5&905NfA7((BOSSPP�O�AE93CO1 USA DRAFTER: D Ryan EN DETAIL 01, FLASHED L FOOT TO F 11�=-/ VV UU ��711�7U U Si S100 PEN D01 RAFTER r u DATE: ITV 120 113 �O[�]Q�BQ11�J c��� ��o�oF� w.���� �.�� ,,,,� n��o.�.no. I APPROVED BY: