Plans PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-SCALE: NTS MODULE NOTES: TABLE OF CONTENTS
1. 3640W DC, 3300W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK) DIMENSIONS:
2. (14) REC SOLAR: REC260PE(BLK) MODULES WITH (1)ABB: MAGNETIC TRUE 65.55"x 39.02"x 1.5" PAGE
ARRAY PITCH �� f.t.,, .�,t: , �� # DESCRIPTION
PVI-3.0-OUTD-S-US-A(240V) INVERTER. ORIENTATION ORIENTATION , ; ,_, _ 2. PORTRAIT: CLAMP 8.2"-16.4"FROM EDGE
3. TWO STORY COMP SHINGLE ROOF AT 34°PITCH. 3. LANDSCAPE: CLAMP 0"-9.8"FROM EDGE
4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT AR-01 34° 164° 180° PV-01 SITE PLAN&MECHANICAL
TES: 1
RUN STRU T WITH CUSTOMER. .. 1. NRAOCK SERIES 100 OR S100 UL LISTED; PV-I[�ECE V TIDAL
5. ROOF STRUCTURE: 2X4 PRE FABRICATED TRUSSES
24"OC. FLUSH MOUNT L-FOOT. SEE PEN D01. ,
6. APN#:2S111DA15200 2. LAG SCREWS: 5/16"X 3.5": 2.5" MIN EMBEDMENT
7. CONTACT: WILLY LIAG, 503-317-9798 ;:i'._ , Sw Brien r, r 3. RAFTER AND PENETRATION LOCATIONS TO BE FEB 2 2015
8. DESIGN CRITERIA: DETERMINED IN THE FIELD.
8.1. SYSTEM WEIGHT: 3LBS/SQFT. 4. INSTALLER TO VERIFY RAFTER SIZE, Cii Y OF' I ,
8.2. EFFECTIVE WIND SPEED: 95 MPH 3-SEC GUST. AND UNSUPPORTED SPANS AND NOTIFY E.O.R
8.3. EFFECTIVE SNOW LOAD:25 LB/SQR FT. 44..._ OF ANY DISCREPANCIES BEFORE PROCEEDING. BUIL DING DIVISION
"' g.7' Y SW AvC+f P
SITE PLAN -SCALE=1116"= 1' f∎ D1 -AR-01 -SCALE: 1/8"= 1'-0" li
- r ��r
(N) SUN RUN METER • INDICATES TSRF VALUE AT MARKED LOCATION
(INTERIOR WALL)
(E) DRIVEWAY
(N) INVERTER WITH —6' 10" 13'-2" 11'
INTEGRATED DC DISCONNECT (E) MAIN PANEL
(INTERIOR WALL) (INTERIOR WALL) I
■
SW PIPPEN LN
{ _
2'-3"
FL PL n --. ■a a *1a 99% I
_ % 94%
(E) RESIDENCE 4'TYP -
_, \ a a
a
116d4,),,--° —e- _099_.%• _a — >-- -e—
a 4 • 10'-11"
%I 4 '0 o — o— s— —e- —0— e— —
C 8._9'
" 9-- O , }}
a a 9 6— b—4'---t-- —9 o— 9-- —e Q
• a L
23'
a (E) SKYLIGHT
(E) SERVICE ENTRANCE T 28-4 CITY Coil TIGARD
(EXTERIOR WALL)
0
REVIEWED FOR CODE COMPLIANCE
Approved: [i 4
OTC: [
T 24( •
Aaai rte► it�'11
12" FIRE SETBACKS a 6
By: - mall Dates 4` 7
26'-7" V' t • - .
PL PL 20'
20\\— OFFICE COPY
•
(E) PROPERTY LINE
ROOF AREA: 1801 SQ.FT.
ARRAY AREA: 238 SQ.FT. (N)ARRAY AR-01
COVERAGE: 13%
SUNRUN,INC. 3360SE20TH,PORTLAND,OR97202 REV:A
sunrun OR CL#180464 PHONE 503.766.4332 DESIGNER: F. JAVIDKIA SUNRUN PROJECT NUMBER: LIAG RESIDENCE SITE PLAN & PV 01
FAX 503.205.0748 LIAG (601 R-900LIAN) 8900 SW PIPPEN LN., PORTLAND, OR 97224-5238 MECHANICAL 1/14/2015
o DRAFTER: DV
LINE DIAGRAM:
120/240 VAC
SINGLE PHASE SERVICE
METER
G
I PGE 24522
2931
UTILITY
GRID
b EXISTING
C200A MAIN
p BREAKER
EXISTING
< . 200A MAIN ABB: PVI-3.0-OUTD-S-US-A JUNCTION BOX
FACILITY PANEL SUN RUN (240V) 3000 WATT INVERTER MIN RATED NEMA3R
METER (OR EQUIVALENT)
LOADS ' PV MODULES
.r �2 �1 /
3 3 _ G--e�o / REC SOLAR: REC260PE(BLK)
��
—0 —� +� / (14) MODULES
0 ono (1) STRING OF (14) MODULES
FACILITY
20A PV GROUND 250V METER SOCKET DUAL MPPT TRACKERS STRING
BREAKER AT 125A CONTINUOUS & COMBINER & LOAD RATED DC
OPPOSITE END 240V METER DISCONNECT AND AFCI
OF BUSBAR 200A, FORM 25
NOTES TO INSTALLER: CONDUIT SCHEDULE SIGNAGE: •
WARNING
1. 529 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE.
2. REPLACE (2) EXISTING 15A 2P BREAKERS WITH (1) NEW 15/20/15A 1-2-1P # CONDUIT CONDUCTOR NEUTRAL GROUND WARNING-Dual Power Sources Secondsourceisphotovoltaicsystem ELECTRIC SHOCK HAZARD
QAUD BREAKER. CONNECT PV TO THE NEW 20A PORTION OF QAUD. . DO NOTTOUC-1 TERMINALS
LABEL PLACEMENT:MAIN PANEL TERMINALS ON BOTH LINE AND
1 NONE (2) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER NEAR METER LOAD SIDES MAY BE ENERGIZED
. -
WARNING IN THE OPEN POSITION
2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 „ „s ,,,
lvE,C„wgE ,O„
„r DC VOLTAGE IS ALWAYS PRESENT
LABEL PLACEMENT:AC DISCONNECT, WHEN SOLAR MODULES
3 3/4” EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 COMBINER BOX,INVERTER ARE EXPOSED TO SUNLIGHT
WARNING-Electnc Shock Hazard_ LABEL PLACEMENT:
No user serviceable parts inside r DC DISCONNECTS
Contact authorized servicer for assistance
LABEL PLACEMENT:AC DISCONNECT, WARNING
COMBINER BOX,INVERTER
ELECTRICAL NOTES: CAUTION:SOLAR ELECTRIC ELECTRIC SHOCK HAZARD
SYSTEM CONNECTED IF A GROUND FAULT IS INDICATED
1. PHOTOVOLTAIC SYSTEM WILL LABEL PLACEMENT
NORMALLY GROUNDED CONDUCTORS
COMPLY WITH 2011 NEC. CONDUIT.JUNCTION BOXES MAY BE UNGROUNDED AND ENERGIZED
2. ELECTRICAL SYSTEM GROUNDING PHOTOVOLTAIC POWER ' LABEL PLACEMENT:
WILL COMPLY WITH 2011 NEC. SOURCE NVERTER
3. PHOTOVOLTAIC SYSTEM IS COND PLACEMENT
CONDUIT,JUNCTION BOXES WARNING
UNGROUNDED. NO CONDUCTORS ( 1 ELECTRIC SHOCK HAZARD
ARE SOLIDLY GROUNDED IN THE l J DO NOT TOUCH TERMINALS
INVERTER. SYSTEM COMPLIES LABEL PLACEMENT: TERMINALS ON BOTH LINE AND
ALL DISCONNECTS LOAD SIDES MAY BE ENERGIZED
WITH 690.35. MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS -INVERTER 1 IN THE OPEN POSITION
4. MODULES CONFORM TO AND ARE ' LABEL PLACEMENT:
LISTED UNDER UL 1703.
REC SOLAR: REC260PE(BLK) 260 W SYSTEM SIZE 3640 W AC DISCONNECTS
5. INVERTER CONFORMS TO AND IS OPEN CIRCUIT VOLTAGE 37.8 V SYSTEM OPEN CIRCUIT VOLTAGE 576 V WARNING
LISTED UNDER UL 1741. - —
6. ARRAY DC CONDUCTORS ARE OPEN CIRCUIT VOLTAGE: (690.7) 41.1 V SYSTEM OPERATING VOLTAGE 429.8 V ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
SIZED FOR DERATED CURRENT. MAX POWER VOLTAGE 30.7 V MAX ALLOWABLE DC VOLTAGE 600 V PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE ENERGIZED
9.01 AMPS MODULE SHORT .
CIRCUIT CURRENT. SHORT CIRCUIT CURRENT 9.01 A SYSTEM OPERATING CURRENT 8.5 A LABEL PLACEMENT.
14.07 AMPS DERATED SHORT SHORT CIRCUIT CURRENT (690.8(A)(1)) 11.26 A SYSTEM SHORT CIRCUIT CURRENT 11.26 A JUNCTION I DISCONNECTS
COMBINER BOXES,
CIRCUIT CIRCUIT(690.8 (a) &690.8
(b)). LABEL PLACEMENT:AC BREAKER
(INSIDE OR FRONT OF PANEL)
SUNRUN,INC. 3380 S E 20TH.PORTLAND.OR 97202 DESIGNER:
sunrun OR CL#180464 PHONE 503 F JAVIDKIA SUNRUN PROJECT NUMBER: LIAG RESIDENCE REV: A
FAX 503 DRAFTER: DV LIAG (601 R-900LIAN) 8900 SW PIPPEN LN., PORTLAND, OR 97224-5238 ELECTRICAL PV-02 1/14/2015
REVISION:
NOTES:
,
- 5/16" LAG BOLTS MUST EMBED
2.5" INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT
- TORQUE ALL 5/16" HARDWARE TO ON TOP OF FLASHING - -
SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT
. COMPOSITION L FOOT - SILVER S.S. 10-16 FT-LBS
CAN BE MOUNTED IN 5 S.S. FLANGE NUT - BLACK S.S. 7-9 FT-LBS STEP 2: SLIP FLASHING OVER
ANY ORIENTATION - RAILS CAN MOUNT TO EITHER SIDE L FOOT BASE AND UNDER ROW
35 X 1" (OR 1.25") OF L FOOT (UPSLOPE VS DOWNSLOPE) OF SHINGLES ABOVE
SNAPNRACK n, S.S. BOLT AND
1\
CHANNEL NUT SPLIT WASHER
V
��� % ‘ '' / �" S.S. LAG SCREW
\ ��'' WITH FLAT WASHER
SNAPNRACK ��j 2.5" MINIMUM EMBEDMENT ........ ----P------:91111111111°1111111111111111111111111111111.11.--
STANDARD RAIL IS STANDARD
SNAPNRACK COMPOSITION
ROOF FLASHING ._.7 STEP 1: BOLT L FOOT
BASE TO ROOF WITH
LAG BOLT
SNAPNRACK L FOOT BASE ROOF DECKING TYP.
)7//'
ROOF DECKING TYP.
FLASHED L FOOT MOUNTING POINT FOR
USE ON COMPOSITION ROOF SURFACES
WITH LOW TO MODERATE TILT
\•••••
RAILS CAN BE LEVELED UP TO 3" USING iat _ __ __, ______-
UP TO TWO LEVELING SPACERS AS
SHOWN IN "SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION
RAFTER TYP.
SnMAINSTREAM
(//�\\���I^��`�\\\\\ ///�\�///���/�7w ENERGY CORP. DESIGNER: G McPheeters _ SCALE: DNS PART NUMBER: DESCRIPTION: REV
\\ JI(��)J)��\l Jlll Ifll 75`ER°HONE(805 5&905NfA7((BOSSPP�O�AE93CO1 USA DRAFTER: D Ryan EN DETAIL 01, FLASHED L FOOT TO F
11�=-/ VV UU ��711�7U U Si S100 PEN D01 RAFTER r
u DATE:
ITV 120 113
�O[�]Q�BQ11�J c��� ��o�oF� w.���� �.�� ,,,,� n��o.�.no. I APPROVED BY: