Report ■
L
(IA COMcheck Software Version 3.9.4 49.., P .oR,,s'o
Interior Lighting Compl .� �+Sl875PE
Certificate
2014 Oregon Energy Efficiency Specialty Code ✓•N..: 2•�gps,
Section 1: Project Information ��t' OCT T 27 Z014
Project Type:New Construction
Project Title : Michael Kors-Washington Square
Construction Site: Owner/Agent: Designer/Contractor: r
1.!
Michael Kors-Washington Square Michael Kors M-Engineering �
9585 Washington Square Rd.-Space GO6 750 Brooksedge Blvd
Portland,OR 97223 Westerville,OH 43081 NOV 4 2014
614-839-4639
mengineering.us.com CifYOFrici RD
Section 2: Interior Lighting and Power Calculation BOIONSWRIOr
A B C D
Area Category Floor Area Allowed Allowed Watts
(ff2) Watts/ft2 (B x C)
Sales Area(Retail:Sales Area)(Ceiling Height 11 ft.) 3060 1.5 4590
Allowance:Furniture,clothing,cosmetics highlighting/Fix.ID:B1 1000(a) 1.4 1400(b)
Allowance:Furniture,clothing,cosmetics highlighting/Fix.ID:C3 2050(a) 1.4 2870(b)
Restrooms(Common Space Types:Restrooms)(Ceiling Height 9 ft.) 64 0.82 52
Stock Area(Common Space Types:Active Storage)(Ceiling Height 11 ft.) 1030 0.63 649
Fitting Rooms(Common Space Types:Dressing/Locker Room)(Ceiling Height 9 112 0.52 58
ft.)
Fitt Rm Vest(Common Space Types:Corridor/Transition)(Ceiling Height 11 ft.) 80 0.41 33
Office(Common Space Types:Office-Enclosed)(Ceiling Height 9 ft.) 40 0.97 39
Closet(Common Space Types:Active Storage)(Ceiling Height 12 ft.) 150 0.63 95
Total Allowed Watts= 9786
(a)Area claimed must not exceed the illuminated area permitted for this allowance type.
(b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less.
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
Sales Area(Retail:Sales Area 3060 sq.ft.) AMINIthdiftiMilliMMINNIMMIK
Track lighting 1:B1:TRACK:Wattage based on 30 feet of track 0 0 1500 1500
HID 3:C3:SEMI RECESSED:Ceramic Metal Halide:Electronic: 3 52 78 4056
Compact Fluorescent 1:D:PENDENT:Twin Tube 7W:Electronic: 4 11 28 308
Linear Fluorescent 1:Fl:FLUORS.STRIP-MWC:Other:Electronic: 1 64 8 Exempt
Exemption:Furniture-mounted supplemental task lighting
Linear Fluorescent 3 copy 1:F2:FLUORS.STRIP-MWC:22"T5 14W:Electronic: 1 6 14 Exempt
Exemption:Furniture-mounted supplemental task lighting
Linear Fluorescent 3:F3:FLUORS.STRIP-MWC:35"T5 21W:Electronic: 1 34 21 Exempt
Exemption:Furniture-mounted supplemental task lighting
Linear Fluorescent 2:F4:FLUORS.STRIP-MWC:46"T5 28W:Electronic: 1 52 28 Exempt
Exemption:Furniture-mounted supplemental task lighting
Linear Fluorescent 2 copy 1:F4:FLUORS.STRIP-MWC:46"T5 28W:Electronic: 1 22 28 Exempt
Exemption:Advertising/Directional Signage
Linear Fluorescent 3 copy 1:F3:FLUORS.STRIP-GC:35"T5 21W:Electronic: 1 7 21 147
Linear Fluorescent 2 copy 2:F4:FLUORS.STRIP-GC:46"T5 28W:Electronic: 1 12 28 336
Project Title: Michael Kors-Washington Square Report date: 10/27/14
Data filename: P:\1341 xxxx\13411052\06Design\Elec\13411052.cck Page 1 of 4
LED 1:N1:60W LED Driver:Other: 1 2 60 120
LED 1:R2:DOWNLIGHT:LED PAR 20W: 1 2 20 40
Linear Fluorescent 11:TP:FLUORS.STRIP:46"T5 28W:Electronic: 1 42 7 294
LED 1 copy 1:TU:12W PER FOOT:Other: 1 66 12 792
Restrooms(Common Space Types:Restrooms 64 sq.ft.)
Linear Fluorescent 7 copy 1:M1 F:2X2:22"T5 14W:Electronic: 2 1 28 28
Stock Area(Common Space Types:Active Storage 1030 sq.ft.)
Linear Fluorescent 10:M:1X4:48"T8 32W:Electronic: 2 11 64 704
Fitting Rooms(Common Space Types:Dressing/Locker Room 112 sq.ft.)
HID 3 copy 1:C2FL:SEMI RECESSED:Ceramic Metal Halide:Electronic: 2 4 52 208
Fitt Rm Vest(Common Space Types:CorridoriTransition 8,0 sq.ft,.)
LED 1 copy 1:R2:DOWNLIGHT:LED PAR 20W: 1 3 20 60
Office(Common Space Types:Office-Enclosed 40 sq.ft.)
Linear Fluorescent 7 copy 2:Ml:2X2:22"T5 14W:Electronic: 2 1 28 28
Closet(Common Space Types:Active Storage 150 sq.ft.) --i ^��
Linear Fluorescent 7 copy 3:Ml:2X2:22"T5 14W:Electronic: 2 2 28 56
Total Proposed Watts= 8677
Section 4: Requirements Checklist
In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks
identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in
the plans/specs the requirement can be verified as being satisfied.
Lighting Wattage:
❑ 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Wattage:9786 Proposed Wattage:8677
Complies:YES
Mandatory Requirements:
❑ 2. Exit signs.Internally illuminated exit signs shall not exceed 5 watts per side.
Plans reference page/section:
❑ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting
in the non-daylight zone.In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic
daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent,and provide an automatic OFF control,
while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a
single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e.,north,east,
south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration.
Exception(s):
❑ Retail spaces adjacent to vertical glazing(retail spaces under overhead glazing are not exempt).
❑ Display,exhibition and specialty lighting
❑ HID lamps 150 watts or less.
❑ Spaces required to have occupancy sensors.
Plans reference page/section:
❑ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and
each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are
a remote switch that identifies the lights served and indicates their status.
Exception(s):
❑ Lighting systems serving areas designated as security or emergency areas that must be continuously lighted.
❑ Lighting in public areas such as concourses,stairways or corridors that are elements of the means of egress with switches that
are accessible only to authorized personnel.
❑ Lighting for warehouses,parking garages or spaces using less than 0.5 watts per square foot.
❑ Lighting for contiguous,single-tenant retail spaces.
Plans reference page/section:
❑ 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room.
Plans reference page/section:
❑ 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during
periods that the building space served by the means of egress is unoccupied.
Exception(s):
Project Title: Michael Kors-Washington Square Report date: 10/27/14
Data filename: P:\1341xxxx\13411052\06Design\Elec\13411052.cck Page 2 of 4
❑ Building exits as defined in Section 1002 of the Oregon Structural Specialty Code.
Plans reference page/section:
❑ 7. Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of
Sections 505.2.2.1 and 505.2.2.2.
Plans reference page/section:
❑ 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least
50 percent by either
1)controlling(dimming or multi-level switching)all luminaires;or
2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or
3)switching the middle lamp luminaires independently of other lamps;or
4)switching each luminaire or each lamp.
Exception(s):
❑ Only one luminaire in space.
❑ An occupant-sensing device controls the area.
❑ The area is a corridor,storeroom,restroom,public lobby or sleeping unit.
❑ Electrical and mechanical room.
❑ Areas that use less than 0.6 Watts/sq.ft.
Plans reference page/section:
❑ 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic
control device shall function on either:
1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not
exceed 10,000 square feet and are not more than one floor;or
2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or
3)a signal from another control or alarm system that indicates the area is unoccupied.
Exception(s):
❑ Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safety or security.
Plans reference page/section:
❑ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation.
Plans reference page/section:
❑ 11.An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space.
Exception(s):
❑ Classrooms and lecture halls.
❑ Conference,meeting and training rooms.
❑ Employee lunch and break rooms.
❑ Rooms used for document copying and printing.
❑ Office spaces up to 300 square feet.
❑ Restrooms.
❑ Dressing,fitting and locker rooms.
Plans reference page/section:
❑ 12.Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a
space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and
supply rooms up to 1000 square feet.
Plans reference page/section:
❑ 13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device
that:1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or
so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an
override is initiated,and 5)controls an area not exceeding 2,000 square feet.
Exception(s):
❑ In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,where captive-key override is
utilized,override time is permitted to exceed 2 hours.
❑ In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,the area controlled shall not exceed
20,000 square feet.
Project Title:Michael Kors-Washington Square Report date: 10/27/14
Data filename: P:\1341xxxx\13411052\06Design\Elec\13411052.cck Page 3 of 4
i
Plans reference page/section:
❑ 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature
that turns off all loads for at least 24 hours,then resumes the normally scheduled operation.
Exception(s):
❑ Retail stores and associated malls,restaurants,grocery stores,places of religious worship,theaters and exterior lighting zones.
❑ Single zone electronic time control devices and self-contained wall box preset lighting controls.
Plans reference page/section:
❑ 15.Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a
photosensor and a time switch,or an astronomical time switch.Lighting designated for dusk-to-dawn operation shall be controlled by
an astronomical time switch or photosensor.
Plans reference page/section:
❑ 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired:
1.Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet
center-to-center of each other.
2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted
within 1 foot edge-to-edge of each other.
Exception(s):
❑ Where electronic high-frequency ballasts are used.
❑ Luminaires on emergency circuits.
❑ Luminaires with no available pair in the same area.
Plans reference page/section:
❑ 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control
of the nonexempt lighting.
Plans reference page/section:
❑ 18.Each dwelling unit in a building is metered separately.
Plans reference page/section:
Interior Lighting PASSES:Design 11%better than code.
Section 5: Compliance Statement
Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and
other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy
Efficiency Specialty Code requirements in COM check Version 3.9.4 and to comply with the mandatory requirements in the Requirements
Checklist.
:G-s ,6w,-7 —C�J'+rc/�/�r/.G�'s/J.: "� %c-.2!-/'f
Name-Title Signature Date
Project Title: Michael Kors-Washington Square Report date: 10/27/14
Data filename: P:\1 341 xxxx\13411052\06Design\EIec113411052.cck Page 4 of 4
PERMITS TODAY
RECEWFD
NOV 422.00�1/4o4
November 3,2014 `ITYOk•Cll7�+1)
Attention Building Permit Technicians
BUIWvn 1���n�'
CITY OF TIGARD BUILDING DIVISION
13125 SW Hall Blvd.
Tigard, OR 97223
Re: Plan submittal for Tenant Improvement of retail store in an existing space
"Michael Kors" located at 9620 SW Washington Square Rd., Sp. #G06,Tigard OR 97223
Dear Building Permit Technicians:
Please fmd attached for Plan review 3 sets of plans. We have enclosed the Energy Calcs,
Structural Calcs, Permit Commercial Application, Commercial Checklist, "Barrier Rem. Plan"
Form and a check of$3,032.14 for the plan review fees. Per our conversation with Debbie in
your department, our plan review fees are$3,032.14 based on the valuation.
The job valuation for this project is$395,000.00.
Const. Type: II B Fully Sprinklered Occup. Type: M-Retail Occup. Load: 114
TOTAL SQUARE FOOTAGE 4,523
If it is at all possible could we please have a receipt for our plan review fees and any
approval/corrections faxed to us at 626/792-5777. Please call us if you have any questions.
Sincerely,
Gabriela Ortiz
CONTACT: Scott Daves @ Permits Today
140 So. Lake Ave., Suite 323
Pasadena, CA 91101
Tel. 626/585-2931
Fax 626/792-5777
pennitstoday@aol.com
140 south Lake Ave. #325 • Pasadena, CA 91101 • Tel: 626-585-2931 Fax: 62.6-792-5777
2
PI
PERMITS TODAY
ARCHITECT: Two One Two Design
45W 21st St., Suite#403
New York, NY 10010
Tel. 212/904-0432
Fax 212/904-0433
TENANT: Michael Kors
1 Meadowlands Plaza
East Rutherford, NJ 07073
Chris Munden
Tel. 201/812-2576
Fax 646/376-6271
CONTRACTOR: TBD
OWNER/LANDLORD: Macerich
Eric Fong
401 Wilshire Blvd., Suite#700
Santa Monica, CA 90401
Tel. 310/899-6655
Any other questions please feel free to contact my self at the above number. Please fax a copy of
any comments to our offices at 626/792-5777.
Thank you.
140 South Lake Ave. #325 • Pasadena, CA 91101 • Tel: 626-585-2931 Fax: 626-792-5177