Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
RECEIVED JAN 26 2015 CITY BUILDING DIVISION BUIL SIEMENS 15201 NW Greenbrier Parkway Suite A-4 Beaverton,Oregon 97006 Phone: (503)207-1900 Fax:(503)207-1901 CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: [ %4 OTCs [ Permit#t — I Address: 4/1,, -411 jif ►-kca Suite# By: Dates (5— a OFFICE COPY WASHINGTON SQUARE MALL IVIVAA ATHLETICA TI SPACE #G15 Submittal Version Date Siemens Job Number 440P-X)000( Rev 0 01/20/15 • Siemens Project Manager 0 Volesky Siemens Project Engineer Mohsin Malik Proprietary document for approval only Table of Contents SIEMENS EQUIPMENT LIST / BILL OF MATERIALS COMPONENT SPECIFICATIONS - FIRE ALARM SYSTEM TAB-1 EQUIPMENT LIST/ BILL OF MATERIALS BILL OF MATERIALS SIEMENS Washington Square Mall lviwa Athletica TI Space#G15 440P-XXXXX Fire Alarm System Item Part# Qty Mfg Description 1 STWC 1 Wheelock Exceder Series Strobe, Multi-Candela, Ceiling-Mount,White Note: Candela settings are field-selectable for 15/30/60/75/95/115/150/177 cd 2 ET90-24MCC-FW 1 Wheelock ET Series Speaker/Strobe, Multi-Candela, Ceiling-Mount,White Note: Candela settings are field selectable for 15/30/75/95 cd PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1 1/20/2015 TAB-2 COMPONENT SPECIFICATIONS FIRE ALARM SYSTEM SIEMENS Data Sheet Fire Safety & Security Products 'EXISTING FACP MXL Panel > LOCATION: SERVICE CORRIDOR Advanced Fire Protection System BEHIND YANKEE DOODLE G01 ARCHITECT AND ENGINEER SPECIFICATIONS • FirePrinem application-specific detection • Logic controlled output functions • More than 2,000 intelligent input-device capacity • Multiple levels of password protection • Dynamic supervision of intelligent devices • Automatic environmental compensation tiIMIEN] for smoke detectors • Multiple command stations • Security-device monitoring • One-person'walk test'via'loop,"zone' - • Sprinkler supervision or'system' • Detector-sensitivity readout/printout, • Alarm verification by'device'or'zone' • Time-base controlled output functions per NFPA 72 Chapter 7 • Intelligent/analog detection circuits: • City Tie/Lease Line —Style 6(Class A)or Style 4(Class B) • Coded outputs • Conventional initiating circuits: • Supervised serial annunciator —Style D(Class A)or Style B(Class B) driver/input Interface • Notification appliance circuits[NACs]: • 16-gauge steel enclosure —Style Z(Class A)or Style Y(Class B) • Multi-language display • Degrade-mode operation • Intelligent interface to building/ • Distributed processing - process-management systems • 80-character backlit,alphanumeric display • Operates as an interactive peer with • 32-character custom messages other MXL,MXL-IQs or MXLV systems • Thermal-strip printer in a LifeLINK Network • Supervised remote printer • Pre-alarm operation • Compare system software • NCC graphics • Fully field programmable,via laptop PC • NEC 760 power-limited circuits • Menu-driven operator commands r st I (®UL 864 9th Edition compliant) • Central&distributed architecture • SinorixTM NFPA Approval(2001) • Up to 800-event history log with online • UUKL Listed for Smoke Control and offline reports • ®UL 864 9th Edition Listed, ULC Listed; • User help screens CSFM,NYC Fire Department and • Holiday schedule City of Chicago Approved System Overview The MXL fire panel is a microprocessor-based The MXL system is approved by CSFM, NYMEA and the City advanced protection system. The use of the MXL of Chicago for use in those specific locales. system's unique multiprocessor'network'design;as In addition to the standard fire applications, MXL is well as its ability to utilize analog and conventional ®UL Listed, under the category'UUKL for Smoke Control.' detection devices,makes the MXL panel a highly The MXL panel can be used as a listed fireman's smoke- flexible and reliable fire-control system. control station in high-rise office buildings, malls and The MXL panel is ideally suited for commercial, other multi-level or vast structures. The MXL industrial and institutional fire-detection and system also complies with Uniform Building Code notification applications. The MXL system Section 905 requirements for smoke control. complies with the requirements of NFPA Standard The MXL panel is Listed for releasing SinorixrM 72, and is listed by®Underwriters Laboratories(UL), Engineered Fire Suppression System. MXL follows the via its®UL 864 9th Edition. 40 Underwriter's' releasing requirements specified in the NFPA 2001. Laboratories of Canada (ULC)also lists the MXL panel for fire applications. MXL Panel 5000 SIEMENS Industry, Inc. Building Technologies Division MXL Components The basic MXL control unit consists of the following • [2]two-line,80-character LCD display sub-assemblies: MMB-3 Main Control Board; MPS-6/ • indicator LEDs MPS-12 Power Supply; MKB-2 Annunciator and • display-control keys • Keyboard; MME-3, or MLE-6 Enclosures. Optional numeric keypad • 12 programmable ss ry on keys modules—which can be installed with the MXL • all other keys necessary for operator control System—include: MOM 214 Expansion Card Cage; These keys include but are not limited to: Acknowledge; ALD-2I Analog Loop Driver;CRM-4 Controllable Relay Silence and Reset. Model MKB-2 also includes spaces Module; NIM 1 W Network/Foreign Systems Interface for mounting the Model MMM-1 microphone module Module; REP-1 Network Repeater Module;CSM-4 and the Model TMM-1 telephone. Model MKB-2 is Controllable Signal Module;CZM-4 Conventional Zone supplied with two(2) blank plates for use when either Module; PIM-1 Peripheral Interface Driver;CMI-300 the microphone or telephone is omitted. NCC-WAN Modem Interface Module; PSR-1 Remote Power Supply; NET-4 Style 4 Network Interface, and Display/Keyboard (MKB-5) NET-7 Style 7 Network Interface. Additionally,the MXL system includes option modules :,. MOI-7 System Interface, MOD-16 Output Driven and MID-16 Point Input Module. These option modules can be used to drive graphic annunciators and fireman's smoke control stations,or to monitor foreign systems. MKB-s The MXL is compatible with a full line of intelligent The MKB-5 display keyboard,which mounts on the inner initiating devices highlighted by the FirePrintlM door of any MXL enclosure, provides: application-specific detectors: Models FP-11 and FPT- • 6-1/4'VGA backlit,80-character LCD display 11. The MXL panel is also compatible with FireFinder, • indicator LEDs the NCC series of text and graphic command centers. • 12 programmable function keys • numeric keypad MXL Enhanced Main Board (MMB-3) • user-programmable function keys • all other keys necessary for operator control - I These keys include but are not limited to: Acknowledge; f ` " - Silence and Reset. Multiple Model MKB-5 modules can be - i used;each providing full control of the MXL system. Up to . four(4)Model MKB-5 can operate in a fully supervised mode;each with independent, built-in printer 1 driver capability. MMB-3 Power Supply (MPS-6) The function control of the MXL is contained on the MMB-3 Main Control Board. Model MMB-3 offers a fast, integral microprocessor and installation conveniences such as diagnostic LEDs and removable terminal blocks for field wiring. Model MMB-3 acts as the central controller for the system, and includes two(2) ALD circuits and two (2) notification appliance circuits. Model MMB-3 mounts in the MXL enclosure back box. Display/ Keyboard (MKB-2) MPS-6 Model MPS-6 is a fully supervised power supply that a _._ provides the MXL system with primary DC power. Model MPS-6 is rated at 6.5 Amps, and is unfiltered and unregulated. Model MPS-6 supplies power to the MXL e Control Unit,and supplies its expansion modules with power required for normal operation. Model MPS-6 incorporates a circuit breaker on the primary input,and MKB-2 includes a built-in AC-line filter for surge and noise The Model MKB-2 display keyboard,which mounts suppression. Model MPS-6 mounts in the MXL enclosure on the inner door of any MXL enclosure,provides: back box. SIEMENS Industry, Inc. Building Technologies Division MXL Components — (continued) Analog Loop Driver(ALD-2I) Power Supply (MPS-12) • •x♦ • • 41 • *"" .}u • ALD-2I MYgp.y Model ALD-2I is a MXL network-option module that • supplies two (2) intelligent analog circuits utilizing Fire Safety"I","IL", and FP series intelligent devices. MPS-12 Model ALD-2I occupies two (2) addresses on the MXL Model MPS-12 is a fully supervised power supply Network and through the use of unique that provides the system with preliminary DC communication-protocol devices connected to the power. Model MPS-12 is rated at 12 Amps, and circuits of Model ALD-2I. The circuits are dynamically is unfiltered and unregulated. Model MPS-12 supervised by the MXL control panel. Up to 60 supplies power to Models PSR-1, MMB-3 and their programmable input and output devices may be expansion modules with power required for connected to each of its two(2) circuits. Each circuit normal operation. Model MPS-12 incorporates may be wired as Class B (Style 4) or Class A (Style 6). a resettable circuit breaker on the primary input, Controllable Signal Module(CSM-4) and includes a built-in AC-line filter for surge and noise suppression. Model MPS-12 mounts in the MXL enclosure back box. .; • I: 111144 Network Optional Module Card Cage (MOM-4) - -:;111111111111111M4 to -14;1 - •°�a_ , � • -1*":1 .g ,. . � • • Arla CSM-4 MOM-4 Model CSM-4 provides two (2) fully supervised, The Model MOM-4 Card Cage provides the MXL programmable notification-appliance circuits. Model CSM-4 supplies two (2) Class B (Style Y) main unit or remote units with card slots for or Class A(Style Z)-type output circuits for the option modules. Each Model MOM-4 supplies supervision and control of listed audible or visual connection space for either two(2) full-width notification appliances such as: horns, bells, option modules: (Models ALD-2I, CZM-4, NIM-1 R) strobes, etc. or four (4) half-width option modules: (Models CSM-4, CRM-4, CMI-300, NET-7, REP-1)or a Each circuit can provide up to 1.5 amps (24 VDC) combination of one (1) full and two)2) half-width of current to power notification appliances. Model modules. CSM-4 is also used for Sinorix. Leased line and municipal-tie connections are also possible with Network Optional Module Card Cage (MOM-2) Model CSM-4. Controllable Relay Module (CRM-4) IIH* 1 I Pt. MOM-2 o"'+ttt t grei!V Model MOM-2 provides the MXL main unit, _,_ remote units. Each Model MOM-2 provides space ; for one (1) full-width module (Models: ALD-2I, �, ' Pt- ;.. CZM-4, and NIM-1 R) or two (2) half-width CRM-4 optional modules (Models: CSM-4, CRM-4, CMI- 300, NET-7, REP-1). Model CRM-4 is designed to provide auxiliary control of building functions such as: door-holder release, elevator capture, smoke control, lock release, etc. Model CRM-4 provides four (4) fully programmable relays. Each relay contains one (1) set of SPDT contacts rated at 2 amps 30 VDC 1 120 VAC resistive. SIEMENS Industry, Inc. Building Technologies Division MXL Components — (continued) Communication Module (NET-4) Model REP-1 provides the ability to configure the ,., _ * local or global networks of the MXL panel in a 'star' I • or'daisy-chain'configuration. Model REP-1 provides .t . - two (2) Style 4 or one (1) Style 7 RS-485 network j circuits. Through the use of Model REP-1, the MXL's I( local network (MXL-MXLR) can be expanded up to .» •. Ili 64 nodes. lai - 4 n - s ..e. IMP Remote Power Supply (PSR-1) NET-4 ', el • • g•Model NET-4 is a plug-in-type module used to >t �. • provide communication between the Fire Safety t MXL panel and various other MXL remote l _ modules. Model NET-4 is designed to plug into - In �— an edge-connector-type slot on the Model PSR-1 jam' Network Supply. Model NET-4 provides NFPA • am.IN Wit ' Style 4-type communication: fully digital; PSR-1 RS-485 operating at 19.2K Baud rate. Model PSR-1 is a microprocessor-controlled remote power supply and battery charger for use with the Style 7 Network Interface Card (NET-7) MXL panel. Model PSR-1 operates in conjunction with either a Model MPS-6 or MPS-12, providing 6 or 12 -' - ' ,. .. a f 4 Amps of power for use with various MXL modules. - When used with a Model NET-4 or Model NET-7 plug- " in communication module, Model PSR-1 becomes •... a part of the MXL panel's internal network. Model " III~ � PSR-1 acts as an interface between remote-option , s „ _ -:, _ R modules and the MXL. NET-7 Peripheral Interface Driver(PIM-1) Model NET-7 is a microprocessor-controlled MXL am= Mr= - network-interface module that allows the wiring • . of the MXL RS-485 network in a NFPA Style 7 11 configuration. Model NET-7 plugs into a half slot -- I • • of the Models MOM-214 card cage at the MXL - command center (MMB-2) and at the Model PSR-1 ; IT or Model MOM-4 slot at the MXL remote units (MXLR, MXLRV). PIM-1 Model NET-7 provides two (2) independent and Model PIM-1 is a MXL option module that provides fully supervised communication paths, allowing a bidirectional, isolated RS-232 port for connection to system operation through an open and short peripheral devices, such as: printers, CRTs,VDTs, color circuit. Model NET-7 also isolates the power graphics, alphanumeric pagers and remote diagnostics supplies at each remote unit, providing the ability hardware. Model PIM-1 mounts in the MXL enclosure, to localize ground-fault conditions. The and connects to Model MMB-3, providing a screw- communication for Model NET-7 operates at terminal block for connection of RS-232. A number of 19.2K Baud rate and is fully digital. supervised and non-supervised formats are available for Model PIM-1. Network Repeater Module (REP-1) Output/ Input Module (MOI-7) I• PI 1 w I REP-1 MOI-7 SIEMENS Industry, Inc. Building Technologies Division MXL Components — (continued) Model M01-7 is a MXL RS-485 network module These inputs can be individually set for: Alarm, that provides a fully programmable serial Supervisory, Trouble, Security or Status usage. interface to Model MOD-16 output drivers and Further, the Model MID-16 inputs can also be MID-16 input drivers. When used with Model configured to provide supervision for lamps driven by MOD-16 drivers, Model M01-7 provides a serial- Model MOD-16 outputs. Screw terminals and annunciator output or relay driver. When used connectors are provided on the Model MID-16 with Model MID-16, Model M01-7 provides modules for interface to monitored devices. programmable inputs. MXL/(V) Standard Size Enclosure (MME-3) Each Model M01-7 can operate up to eight(8) Model MOD-16 drivers and eight(8) Model MID- 16 drivers simultaneously. Each Model MOD-16 output and Model MID-16 input is independently programmable, via the MXL custom software. Output Driver(MOD-16) MME-3 The Model MME-3 enclosure set consists of a sheet- ' metal back box and door with key-lock. Model MME-3 can be used for the MXL System, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment(via the Model MSR-1 Rail Kit). To mount MXL I MXLV modules in Model MME-3, the MOD-16 Model MBR-MP removable-module mounting plate is Model MOD-16 is an output-driver module used in required. conjunction with Model M01-7, as a part of the Using the Model MBR-MP mounting plate—one (1) Fire Safety MXL System. Up to eight(8) Model Model MMB, or one (1) Model PSR-1, and up to three (3) MOD-16s can be connected to a Model M01-7 expansion card cages (Model MOM or Model OMM) can interface module. Each Model MOD-16 provides be mounted in the Model MME-3 enclosure. When used 16 open-collector, current-sinking outputs, which to mount MXL amplifiers (Model EL-410), the Model are rated at 24 VDC, 50mA. Model MOD-16 MBR-MP module is not required. Instead, up to three (3) outputs are programmable, via the MXL custom Model EL-410 amplifiers may be installed in Model MME- software. 3,via three (3) Model MSR-1 Rail Kits. When amplifiers are mounted in any enclosure, always install Model Programmable Input Driver(MID-16) MDG-1 grills in the door for proper ventilation. Model MME-3 is designed for surface of semi-flush mounting, and includes various knockouts for wire and conduit entry. The door in the Model MME-3 set has two (2) cutouts for clear lenses, blank plates or grills— depending on the application—and contains a key-lock. MXL MME-3 and MLE-6 Modules Mounting Plates (MBR-MP) MID-16 Model MID-16 is an input module used in conjunction with Model M01-7, as a part of the Fire Safety MXL System. Up to eight(8) Model MID-16s can be connected to a single Model MOI- 7, along with eight (8) Model MOD-16 output- driver modules. Each Model MID-16 provides a MBR-MP non-supervised input, which can monitor The MXL IV Module Mounting Plate (Model MBR-MP) is normally open contact devices. required for use in both Models MME-3 and MLE-6 Each Model MID-16 input can be separately used enclosures in order to mount all MXL and MXLV as a part of the MXL custom programming logic. equipment. SIEMENS Industry, Inc. Building Technologies Division MXL Components — (continued) Model MBR-MP is not necessary if Models MME-3 Model MBR-3MP allows mounting of an additional three and MLE-6 enclosures are used only for mounting (3) Model MOM or Model OMM module expansion card of amplifiers (Model EL-410D). cages. Model MBR-MP is a removable MXL IV module Various combinations of hardware can be installed in mounting plate that allows the Model MME-3 or Model MLE-6. If only amplifiers are to be installed in Model MLE-6 enclosure to be shipped to the job Model MLE-6, no Model MBR-MP or Model MBR-3MP site for wiring and conduit installation, while the plates are required. Instead, up to five (5) Model EL- system hardware (electronics) is mounted to the 410D amplifiers can be installed by using five (5) Model studs on Model MBR-MP—pre-wired, MSR-1 rail kits. programmed and tested—prior to delivery and Model MLE-6 can also be used to mount up to three (3) installation at the job site. This process allows for MXL card cages and two (2) amplifiers. This faster, more efficient system start-ups with less configuration would be typical of a remote, voice chance of the sensitive electronics being transponder cabinet. In this configuration, one (1) damaged while field wiring and conduit are Model MBR-MP would be used in the upper half of connected to the system enclosure. Model MLE-6 to mount the MXL modules, while the The Model MBR-MP mounting plate bolts to the lower half would use two (2) Model MSR-1 rail kits to Model MME-3 or Model MLE-6 enclosures for easy mount up to two (2) Model EL-410D amplifiers. installation on the job site. Model MBR-MP also Model MLE-6 is designed for surface or semi-flush has handles to allow easy transport and Mounting, and includes various knockouts for wire and mounting. Model The MBR-MP contains mounting conduit entry. The door supplied with the Model MLE-6 studs for one (1) Model MMB or Model PSR-1; one set has three (3) cutouts for either clear lenses, blank (1) Model PIM-1; one (1) Model TBM-2, and up to plates or grills—depending on the application. The door three (3) Model MOM or Model OMM card cages also contains twp (2) key-locks, which are keyed the or two (2) card cages and one (1)TSP-40 Printer same. (same mounting studs as the Model MBR-2 Various combinations of dead-front mounting enclosures). plates are possible with the Model MLE-6 enclosure. A Model MBR-MP is ordered and shipped separately typical MXLV installation would have one (1) Model from the Models MME-3 and MLE-6 enclosures. MKB-2 at the top, and two (2) Model MHD-3 dead- front MXL I(V) Large Size Enclosure (MLE-6) plates in the middle [for 14 VSM I VLM 1 VFM modules per plate] and one (1) or two (2) Model MHD-2 lower dead-front plates. MLE-6 Optional Card cage Mounting Plate (MBR-3MP) MLE-6 The Model MLE-6 enclosure set consists of a sheet- metal back box and door with two (2) key-locks. Model MLE-6 can be used for the MXL system, MBR-3MP MXLV Voice Command Console, MXLR Transponder, Model MBR-3MP is an optional MXL 1 MXLV card MXLRV Voice Transponder or Amplifier Equipment cage mounting plate for use exclusively in the (via the Model MSR-1 Rail Kit.) Model MLE-6 enclosure. When installed in the Model To mount MXLIV modules in Model MLE-6, the MLE-6 back box, Model MBR-3MP adds the option of Model MBR-MP removable module mounting plate mounting up to an additional three (3) Model MOM or is required with the Model MBR-3MP option Model OMM expansion card cages. available for use. Using the Model MBR-MP mounting plate, one (1) Clear Lens(MDL-1) Model MMB or Model PSR-1 and up to three (3) expansion card cages (Model MOM or Model OMM) can be mounted in Model MLE-6. If additional card cages are required, the Model MBR-3MP optional card cage mounting plate can also be installed in Model MLE-6, below Model MBR-MP. MDL-1 SIEMENS Industry, Inc. Building Technologies Division MXL Components — (continued) Model MDL-1 is a clear Plexiglas® lens that fits in Middle Dead-Front Plate for Mounting Switch one (1) of the two (2) openings in the Model MME- and LED/ Fan-Control Modules (MHD-3) 3 enclosure door, or in one (1) of the three (3) openings in the Model MLE-6 enclosure door. One(1)lens is included in the Model MDL-1 package. Sheet Metal Blank Plate (MDB-1) MHD-3 Model MHD-3 is a hinged sheet-metal panel that attaches to the Model MME-3 or MLE-6 enclosure back box,and fits in either the middle of the upper sections of the Model MME-3 MDB-1 or MLE-6 enclosures. Model MHD-3 has openings for two (2)rows of Model VSM-1 Switch Modules; Model VLM-1 LED Model MDB-1 is a sheet-metal blank plate that fits in Annunciator Modules; Model VFM-1 Fan Control Modules, one(1)of the two(2)openings in the Model MME-3 or Model VSB-1 Blank Plates. enclosure door, or in one(1)of the three(3)openings Model MHD-3 has openings for two(2) rows of Model in the Model MLE-6 enclosure door. One(1) blank VSM-1 Switch Modules; Model VLM-1 LED Annunciator plate is in the Model MDB-1 package. Modules; Model VFM-1 Fan Control Modules,or Model VSB- Upper or Middle Dead-Front Panel (MHD-1) 1 Blank Plates. Each row can mount up to seven (7) modules,totaling 14 modules for each Model MHD-3. Model MHD-3 attaches to the backboxes with screw fasteners,and is hinged for easy access to the rear of the modules inside the enclosure. Middle Dead Front Plate for the Switch/LED/ MHD-1 Fan-Control Modules with Printer Cutout(MHD-4) Model MHD-1 is a hinged sheet-metal panel that attaches to the Model MME-3 or the MLE-6 enclosure back box,and fits in the upper or the middle section of the Model MME-3 back box,or the upper or either of the two(2) middle sections of the Model MLE-6 back box. MHD-4 Model MHD-1 has an opening with a cover plate for Model MHD-4 is a hinged sheet-metal panel that attaches the Model TSP-40 printer(when used),and attaches to the Model MME-3 or the MLE-6 enclosure back box,and to the backboxes with screw fasteners. Once in place, fits in the middle section of both enclosures. Model MHD-1 covers and protects modules and wiring; Model MHD-4 has openings for two(2) rows of Model providing dead-front construction to that area. VSM-1 Switch Modules; Model VLM-1 LED Annunciator Lower Dead-Front Panel (MHD-2) Modules; Model VFM-1 Fan Control Modules,or Model VSB-1 Blank Plates. Each row has space to mount four(4) modules,totaling eight(8) modules for each Model MHD-4. Model MHD-4 also has a cutout to display the Model TSP-40 Internal Thermal Strip Printer. Model MHD-4 mounts to the backboxes with screw fasteners,and is MHD-2 hinged for easy access to the rear of the modules and Model MHD-2 is a hinged sheet-metal panel that inside of the enclosure. When in place, Model MHD-4 attaches to the Model MME-3 or the MLE-6 enclosure covers and protects modules and wiring, providing dead- back box, and fits in the lower section of the Model front construction to that area. MME-3,and on the lower two(2)sections of the Model Rail Kit(MSR-1) MLE-6 back box. Model MHD-2 has no openings and attaches to the backboxes with screw fasteners. Once in place, Model MHD-2 covers and protects modules and wiring; providing dead-front construction to that area MSR-1 SIEMENS Industry, Inc. Building Technologies Division MXL Components — (continued) Model MSR-1 is a System 3,m-type rail kit that fits into Model RCC-1 is a remotely located MXL annunciator display either the Model MME-3 or MLE-6 enclosure back box. module. Model RCC-1 contains an 80-character LCD Model MSR-1, which comes with a U-bracket and display and control keypad(MKB), as well as a PS-5N7 a Z-bracket,allows the following modules—or any network interface. other System 3-type module—to be mounted in Model RCC-1 modules can be located anywhere that a Model MME-3 or Model MLE-6 enclosure: annunciation or control is required. Model RCC-1 can be • Model EL-410D amplifier programmed for display only, or can provide display and • Model PS-35 power supply system control. Remote printers,VDT,or graphics • Model BC-35 battery charger • Model M01-7 I I 0 interface computers can be located throughout a facility—provided • Model MID-16 input driver Model PIM-1 is added to Model RCC-1. • Model MOD 16 output driver ®UL Listed Parallel Printer PAL-1 • Model PS-5A power supply ( ) Amp • Model SYS3-MPF0 [for mounting the D2300CP fiber-optic interface modules] When used in the Model MME-3 enclosure three(3) • Model MSR-1 Rail Kits can be installed to mount up to three(3) rows for up to three(3)EL-410D amplifiers. When used in the Model MLE-6, up to five PAL-1 (5)MSR-1 Rail Kit rows can be installed to allow mounting for up to five(5) EL-410D amplifiers. Model PAL-1 is a®UL Listed,supervised parallel-system printer for the MXL panel. Model PAL-1 connects When the Model MLE-6 enclosure is used with the to Model MKB-5 to provide the MXL panel with a Model MBR-MP mounting plate for installation of MXL (1DUL Listed,supervised parallel-system printer. or MXLV equipment, up to two(2) Model MSR-1 Rail Kit rows can also be installed in Model MLE-6 for B6 Intelligent Control Point(ICP-B6) mounting of either two(2) Model EL-410 amplifiers or some complement of System 3-type mount modules. MPS-12 transformer I supply,can accept NET-4 or NET- 7 network interfaces,and includes diagnostic LEDs and two(2)system relays. Model PSR-1 mounts in the upper section of the MXL enclosure back box. Thermal Strip Printer(TSP-40A) ICP-B6 Model ICP-B6 is a field-mounted output module that is it 410 -41111111ftt....7111 capable of being programmed to either a remote bell or horn—or to a speaker or telephone zone. Model ICP-B6 - ,,,., • communicates with the MXL fire panel,via ALD loop. TSP-40A Line-Isolator Module(LIM-1) Model TSP-4OA is a thermal strip printer,designed as an event-logging device for the MXL panel, providing a 1 M permanent-history report of all system activity. Model TSP-4OA mounts in the MXL enclosure,and its printout is visible through a window in the locked-door - enclosure. Printouts are automatically spooled on a .�.-,•. , take-up reel for easy records storage. Remote Command Console(RCC-1) LIM-1 Model LIM-1 is a short-circuit isolator module for use on the analog loops of the MXL panel. Model LIM-1 is capable of providing Style 4 or Style 6 wiring of the ALD loop. Multiple short-circuit isolators can be used on a single ALD loop to prevent loss of protection in the event of a short circuit. RCC-1 SIEMENS Industry, Inc. Building Technologies Division MXL Components — (continued) Details for Ordering 5-Volt Power Supply/Network Interface(PS-5N7) Model Part Number Number Description ?} i..° ALD-2I 500-891618 [2]Two-Loop Analog Driver Di% j 17" CRM-4 500-890401 Programmable Relay[94]Modules '••�_�. i, CSM-4 500-890402 Notification Appliance Circuits[2]Module ICP-B6 500-895303 Intelligent Control Output[B6 chip] NNW �s • LIM-1 500-892361 Short-circuit Line Isolator(ALD) MBR-MP 500-694210 Module Mounting Plate[MME-3,MLE-6] PS-5N7 MBR-3MP 500-694532 Module Mounting Plate[MLE-6 use only] Model PS-5N7 is a 5V power supply and MXL local- MDB-1 500-692070 Blank Metal-Door Inserts network interface module. Model PS-5N7 is an integral MDL-1 500-692069 Plexiglas®Door Insert part of Model RCC-1. Model PS-5N7 can be used to MHD-1 305-092071 Middle!Dead Front!no openings provide a Style 4 or Style 7 network interface for either MHD-2 305-092072 Bottom!Dead Front!no openings a remote transponder for the MXLV panel (with either MHD-3 305-092073 Middle!Dead Front[w/switch openings] Model TBM-2,ACM-1 and VSM-1 I VLM-1 I VFM-1),or MHD-4 305-092074 Middle I Dead Front[wl switch,printer openings] to drive Model OMM-1 and associated MXLV cards. MID-16 500-891747 16-Input Driver Module MKB-2 500-892077 Hinged Display/Control Keyboard 5-Volt Power Supply(PS-5A) MKB-5 500-648727 Multi-Line Display!Control Keyboard Model PS-5A provides 5 Volts for powering Model MO]- MLE-6 500-694530 Large Enclosure 7. Model PS-5A obtains its power from the 24-Volt [holds up to six(6)Model OMM!MOM modules] MMB-3 500-648860 MXL Main Board,Fast Processor power supply in the MXL system. Models M01-7 and MME-3 500-694209 Medium Enclosure[holds up to 6 OMMsI MOMs] PS-5A both mount on System 3 rails,and can also be MOD 16 500-890828 Programmable Output Driver mounted externally to the MXL system. MOI-7 500-892800 Network I f O Interface[Style 4 or 7] Models M0I-7 and PS-5A typically drive remote- MOM-2 500-892766 Expansion Card Cage[2 slots] graphics annunciators or monitor foreign systems and MOM-4 500-890269 Expansion Card Cage[4slots] devices. MPS-6 500-490357 MXL 6-Amp Power Supply MPS-12 500-492209 MXL 12-Amp Power Supply Network Interface Module(NIM-1W) MSR-1 545-092415 Single-Row Rail Kit for Model MBR-2 NET-4 500-891181 Style 4 Communication Module •M NET-7 500-091914 Style 7Communication Module NIM-1W 500-699103 Local and Wide-Area Network Interface Module - ••• PAL-1 500-692407 UL Listed,Field Mounted Parallel Printer PIM-1 500-691324 Peripheral Interface Module NIM-1W PS-5N7 500-892728 Local Network Interface[Style 4 or 7] PSR-1 500-891182 Remote Power Supply!Controller Model NIM-1W allows for the interconnection or RCC-1 500-692533 Remote Command Display Console networking of up to 63 MXL panels. Model NIM-1W REP-1 500-892954 RS-485 Network Repeater provides a RS-485 communications path in either Style TSP-40A 500-634933 Thermal Strip Printer 4 or Style 7 wiring configurations. Model NIM-1W allows MXL panels to have inter-panel logic,as well as communicate in a peer-to-peer manner. Model Related Documentation NIM-1W can be programmed via CSGM logic as a Product Data Sheet Number foreign system interface to communicate with MXLV 5035 external-building management systems. SIEMENS Industry, Inc. Building Technologies Division Installation and Operation Manual [IOM] Model Part Number Number Description M-1 315-090725 Conventional Zone Module ILI-1 11 H 11A 11AH 315-092724 Intelligent Ion Detectors ILP-1 /IPLT-1 315-092594 Intelligent Photo Detectors ILT-1 315-093336 Intelligent Heat Detectors ILI-1 B 1 1 BH 315-093234 Intelligent Ion High Velocity Detectors ILP-2 315-095028 FirePrintTM Application-Specific Detection MSI-10B l 20B 315-093329 Intelligent Manual Station MS-MI 315-092169 Intelligent Metal Manual Station TRI-B6 1 B6D 1 B6R 315-093315 Intelligent Monitor Module[single!dual with array] TRI-B6M 315-094547 Intelligent Mini-Monitoring Module ICP-B6 315-092471 Intelligent Control Output[B6 chip] UM-1 315-092135 Line-Isolator Module FP-11 315-095921 Intelligent FirePrintTM Detector TRI-SID!R 315-096242 Intelligent Monitor Module Note: For further details, refer to MXL IOM manual: 315-092036. Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard SIEMENS Industry, Inc. Florham Park,NJ 07932 Brampton,Ontario er 201 emb 0 Building Technologies Division Tel:(973)593-2600 (91-FS) L6T 5E4 I Canada Supe rs Nov v embet dated 0 FAX:(908)547-6877 Printed in U.S.A. Tel:(905)799-9937 (Rev.2) URL:www.SBT.Siemens.comIFlS FAX:(905)799-9858 Wheelock" ExcederTM Series 00111 COOPER Notification ED Finally, Design and Safety Meet•.• FIRE t% Ceiling Wall n Description: The Wheelock®ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw,no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. - Save up to 14% cost of installation** The Wheelock®ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing fora greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single O Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings,can be set without the use of a tool and are located behind the appliance to prevent tampering. Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting 12 Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,99 dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while U 8 Candela Settings ## it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 / for consistent installation and easy replacement of appliances if ,,, ,K/ required. Wall models provide an optional locking screw for extra Universal Mounting Base secure installation, while the ceiling models provide a captivated Ceiling and Wall Mounts to 5 Backbox Types screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatibility and Requirements -Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock®Patented Sync Protocol -Compatible with UL"Regulated Voltage"using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage"range Compared to competitive models "'Patented "Compared to previous models NOTE:All CAUTIONS and WARNINGS are identified by the symbol a.All warnings are printed in bold capital letters. Lk WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: •Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". •All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. •Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93%(±2%)UL 464(85%UL 1971). •Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current* 24 VDC/24 FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 AO 0.253 0.110 0.140 STC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 ( 0.110 Horn Strobe Ratings per UL 1971 &UL 464 at 24 VDC UL Max Current*at 99 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 UL Max Current*at 95 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 UL Max Current*at 90 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL 464 Model Regulated Voltage 99 dB 95 dB 90 dB 44Z6""m Range VDC - 144N HN 16-33.0 0.064 0.044 0.022 ""*w,, I '•_ HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 l HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Strobe Sync w/SM, Mounting Model Candela DSM or 12/24 VDC* Options y PS-6&PS-8 d Horn Strobes o a to HSR 15/1575/30/75/95/110/135/185 X X a UMB** O HSW 15/1575/30/75/95/110/135/185 X X o UMB** O HSRC 15/30/60/75/95/115/150/177 X X Cr UMB** Cl.) HSWC 15/30/60/75/95/115/150/177 X X °6 UMB** 13 Tti p Strobes 0 STR > 15/1575/30/75/95/110/135/185 X X 0 UMB** L o h 4) STW 13 15/1575/30/75/95/110/135/185 X X ci UMB" STRC r 15/30/60/75/95/115/150/177 X X 0 UMB** -> 0) STWC o 15/30/60/75/95/115/150/177 X X v UMB** y Horn rn c f0 as C HNR • X X rn UMB** N HNW C X X UMB** N HNRC V , X X m UMB** 03 rn W HNWC 00 X X r UMB** *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base Model Legend / ;r ,,."Pill HN = Horn ST = Strobe <r f .. HS = Horn Strobe V C = Ceiling Mount 1 4 ,' W =White N.4?) R = Red � 'w ■ ` 4 Example 1: STRC=Strobe, Red,Ceiling Mount Example 2: HSR= Horn Strobe, Red,Wall Mount Example 3: HSW= Horn Strobe,White,Wall Mount Example. Example: HSWC Tom§ may 9 .:_'.._.. or v r , ''';'4' ~°1 ' yw k.. *UMB Contact Cover Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5 troubleshooting and easy spot mounting options checking (wall models only) NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock®ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe,ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"W x 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50"D. When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464,California State Fire Marshal(CSFM), ULC Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC IMAM matummil WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 11/09 NJ Location FL Location VA Location 273 Branchport Ave. 7565 Commerce Ct. 4401 Wilson Boulevard,Suite 220 Long Branch,NJ 07740 Sarasota,FL 34243 Arlington,VA 22203 P:800-631-2148 P:941-487-2300 P:877-459-7726 F:732-222-8707 F:941-487-2389 F:703-294-6560 www.coopernotification.com Cooper Notification is Wheelock (MEDC1SAFEPATH' WAVES, ' COOPER Notification 5ec,. - COOPER Notification Series ET Speakers and Speaker Strobes • FIRE SERIES ET70 SERIES ET90 Description Features The Wheelock high performance Series ET Speakers and Series • Approvals include: UL Standard 1971, UL Standard 1480, ET Speaker Strobes provide high audio output,clear audibility,dual New York City(MEA),California State Fire Marshall(CSFM), voltage(25/70 VRMS)capability and field selectable taps from 1/8 Factory Mutual(FM), and Chicago(BFP) See approvals by to 8 watts.They are designed to meet the critical needs of the life model in Specifications and Ordering Information safety industry for effective emergency voice communications,tone ADA/NFPA/UFC/ANSI compliant •signaling and visible signaling to alert the hearing impaired. • The low profile design incorporates a speaker mounting plate Meets OSHA 29 Part 1910.165 for faster and easier installation. Each model has a built-in level • Wall mount models are available with Field Selectable Candela adjustment feature and an aesthetic two(2)screw grille cover. Settings of 15/30/75/110cd or 135/185cd (Multi-Candela The Series ET Speaker Strobe models incorporate Low Current models)or 1575cd(Single Candela model) draw Series RSS Strobes. • Ceiling mount models are available with field selectable Strobe options forwall mount models include 1575 cd or Wheelock's candela settings of 15/30/75/95cd or 115/177cd(multi-candela patented MCW multi-candela strobe with field selectable candela models) settings of 15/30/75/110cd or the high intensity MCWH strobe with • Strobes produce 1 flash per second over the regulated voltage field selectable 135/185cd. range Ceiling mount models are available in Wheelock's patented • 24 VDC with wide UL"Regulated Voltage" using filtered DC MCC multi-candela ceiling strobe with field selectable intensities or unfiltered VRMS input voltage of 15/30/75/95cd or the high intensity MCCH strobe with field Synchronize with sync modules or panels with built-in selectable 115/177cd. Wheelock Patented Sync Protocol The strobe portion of all Series ET Strobes may be synchronized • Field selectable taps for 25 or 70 VRMS operation from 1/8 when using the Wheelock DSM Sync Modules,Wheelock Power watt to 8 watts Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer • High efficiency design for maximum output at minimum an easy way to comply with ADA recommendations concerning wattage across a frequency range of 400 to 4000 HZ photosensitive epilepsy. • Fast installation with IN/OUT screw terminals using #12 to Series ET70 and ET90 Speaker Strobes are UL Listed for indoor #18 AWG wires use under Standard 1971 (Signaling Devices for the Hearing Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using#12 to#18 AWG wiring. Color options for Series ET speakers and speaker strobes are red, white,or nickel plated. Pim U L 111> MEA APPROVED S5391 151-92-E 7125-0785:152(ET70/90 MC) S2652 7125-0785:146(E170WP) NOTE:All CAUTIONS and WARNINGS are identified by the symbol A.All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS, FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • "Regulated Voltage Range"is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology"Listed Voltage Range". Table 1: UL Max Current* ET70 Strobe current-Wall Mount ET90 Strobe current-Ceiling Mount ET70/ET90 Speaker 241575W 24MCW 24MCWH 24MCC 24MCCH Strobes 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 16-33 VDC 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 Table 2: ET70/ET90 UL Reverberant dBA @ 10 Feet" `UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v watts 1/8 1/4 1/2 1 2 4 8 units). For strobes the UL max current is usually at the minimum listed voltage(16v for 24v units). For ET Speaker 75.0 78.0 81.0 84.0 87.0 90.0 93.0 audibles the max current is usually at the maximum ET Speaker Strobe 75.0 78.0 81.0 84.0 87.0 90.0 93.0 listed voltage(33v for 24v units). For unfiltered FWR ratings, see installation instructions. ••dBA ratings are based on UL testing under UL Standard 1480 Wiring Diagrams" SERIES ET SPEAKER&STROBE OPERATE SERIES ET SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY(NON-SYNC OR SYNC) WITH MULTIPLE Willi MODULES FROM + + TO NEXT Sync PRECEDING APPLIANCE Strobe NAC CIr. Y APPLIANCE _ OR APPLIANCE •I`d+ m, MI OR VOICE F 0 Note: Figure EVACUATION I DSM#2 PANEL A shows intercon- PANEL + - r — — — — — +To NEXT Strobe NAC Cir. I.0SYnc IMMIX nection to strobe PRECEDING I STROBE OR �0± through sync STROBE, - — — — — - EOLR 0 SYNC MODULE, Ti 1 f — I DSM#3 module. Speaker OR POWER FACP ; „ n to P Sync �m © portion requires 2 OR FACP �I �/ Iil:I Strobe NAC Cir. + 0 separate conduc- tors to FACP. DSM Interconnecting wiring shown.Maximum of STROBE SPEAKER twenty(20) SERIES ET SPEAKER STROBE APPLIANCES SERIES ET SPEAKER STROBE APPLIANCES &ST SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WITH POWER SUPPLIES CLASS "A" DSM STROBE Series PS Power Supplies NAC SYNC � 0 '1 CIRCUIT : • our ,"")'-n 1 ET C\ /� OUTPUTS MLR ,, o+IN 1 © �„�P. F 1-4 ''MINUS 1 'TEMP 4-CLASS `/ �� AUDIBLE A OR ET rI - C 2-CLASS MINUS 2 '' P /�+IN2 STROBE q+OUT2 ������ NAC / C 0 IRCUIT ET C\ RETURN Series PS Power Supplies For wiring information on Power Supplies, please refer to Data Sheet#89100. Specifications and Ordering Information Strobe Sync w/ # # # Agency Approvals Model Order Wall Ceiling Non- DSM or Strobe Can- Model Model Model Mounting Code Mount Mount Sync Wheelock Power dela Color Color Color Options UL MEA CSFM FM BFP Supplies RED White Nickel ET70-24MCW-FR 9020 X - X X 15/30/75/110 X - L,O,P,Q,U,Y X X X X X ET70-24MCW-FW 9021 X - X X 15/30/75/110 - X L,O,P,Q,U,Y X X X X X ET70-24MCW-FN 3091 X - X X 15/30/75/110 • - X L,O,P,Q,U,Y X X X X X ET70-241575W-FR 7848 X - X X 15(75 on Axis) X - L,O,P,Q,U,Y X X X X X ET70-241575W-FW 7853 X - X X 15(75 on Axis) - X - L,O,P,Q,U,Y X X X X X ET70-241575W-FN 3092 X - X X 15(75 on Axis) - - X L,O,P,Q,U,Y X X X X X ET70-24MCWH-FR 3472 X - X X 135/185 X - - L,O,P,Q,U,Y X X X X - ET70-24MCWH-FW 3475 X - X X 135/185 - X - L,O,P,Q,U,Y X X X X - ET70-24MCWH-FN 0061 X - X X 135/185 - - X L,O,P,Q,U,Y X X X X - ET7OWP-2475-FR 9077 X - X X 180 X - - M(Outdoor) X - X X - ET90-24MCC-FW 3164 - X X X 15/30/75/95 - X - L,Q,U,V,Y X X X X - ET90-24MCC-FR 3163 - X X X 15/30/75/95 X - - L,Q,U,V,Y X X X X - ET90-24MCC-FN 3186 - X X X 15/30/75/95 - - X L,Q,U,V,Y X X X X - ET90-24MCCH-FW 3473 - X X X 115/177 - X - L,Q,U,V,Y X X X X - ET90-24MCCH-FR 0139 - X X X 115/177 X - - L,Q,U,V,Y X X X X - ET90-24MCCH-FN 0062 - X X X 115/177 - - X L,Q,U,V,Y X X X X - ET7O-R 7840 X X - - - X - - L,O,P,Q,U,Y X X X X X ET70-W 7844 X X - - - - X - L,O,P,Q,U,Y X X X X X ET7O-N 3097 X X - - - - - X L,O,P,Q,U,Y X X X X X ET9O-R 7842 X X - - - X - - L,Q,U,V,Y X X X X X ET90-W 7846 X X - - - - X - L,Q,U,V,Y X X X X X ET9O-N 3098 X X - - - - - X L,Q,U,V,Y X X X X X # Models are available in either Red or White. Call Customer Service for Order Code&Delivery. NOTE: Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Wheelock Inc.standard terms and conditions. Architects and Engineers Specifications The speaker appliances shall be Wheelock Series ET Speakers and speaker strobe appliances shall be Wheelock Series ET Speaker Strobes or approved equals.The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Signaling Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS,with selectable power taps from 1/8 watt to 8 watts. All models shall have listed sound output of up to 93 dB at 10 feet and a listed frequency response of 400 to 4000 Hz.The speaker shall also incorporate a sealed back construction.All inputs shall employ terminals that accept#12 to#18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one(1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens. The strobe shall be of low current design. Where, Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95 cd or 115/177cd for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 1575 strobe shall be specified when 15 candela UL Standard 1971 listing with 75 candela on- axis is required(e.g.ADA compliance). When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock's DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation.If the sync module or Power Supply fails to operate,(i.e.,contacts remain closed),the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting.The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series ET speakers and speaker strobes shall be white, red or nickel plate. All speakers and speaker strobes shall be backward compatible. NEM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S0310 ET 06/11 NJ Location 273 Branchport Ave. Long Branch,NJ 07740 P:800-631-2148 F:732-222-8707 www.coopernotification.com / Cooper Notification is Wheelock° I,`,I3r11) SAFEPATH' WAVES 'ZVPI COOPER Notification