Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD BUILDING PERMIT 1111 I . COMMUNITY DEVELOPMENT Permit#: BUP2014-00305 T[GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 02/02/2015 Parcel: 2S 1138000600 Jurisdiction: Tigard Site address: 16060 SW 85TH AVE Project: Clean Water Services Subdivision: ROSEWOOD ACRE TRACTS Lot: D Project Description: Replace existing air compressor. Contractor: LYNCH MECHANICAL CONSTRUCTION LLC Owner: CLEAN WATER SERVICES 19305 SW TETON AVE 2550 SW HILLSBORO HWY TUALATIN, OR 97062 HILLSBORO, OR 97123 PHONE: 503-545-6466 PHONE: FAX: 503-218-1120 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: ALT Type of Const: DC Provision Review,COM TI-Ping 02/02/2015 $75.00 Occupancy Grp: Occupancy Load: DC Provision Review,COM TI-LRP 02/02/2015 $11.00 Permit Fee-COM-New Construction 02/02/2015 $252.84 Dwelling Units: 0 12%State Surcharge-Building 02/02/2015 $30.34 Stories: 0 Height: 0 ft Plan Review 02/02/2015 $164.35 Bedrooms: 0 Bathrooms: 0 Info Process/Archiving-Sm$0.50(up to 02/02/2015 $15.00 Value: $16,500 11x17) Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $548.53 Required: Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATT . gon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-0 - 010 through OA 52-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. sued By: Permittee Signature: / A ME Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applica CEIyEf Commercial ��[[jj''�� vv �Cii FOR OFFICE USE ONLY Received City of Tigard ��� Permit g � 2c3 2 3 2014 Date-B : J 13125 SW Hall Blvd.,Tigard,OR Plan Revie ` ��� Phone: 503.718.2439 Fax: 5 9 Date/I3 • t • Other Permit: TI c n I:n Inspection Line: 503.639.4175t, UF TIGARD Date Ready By: • FO is. ® See Page 2 for Internet: www.tigard-or.gol3UILDING DIVISION Notified Method: Q/� j Supplemental Information IF ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all rit Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the work indicated on this application. El 1-and 2-family dwelling p Commercial/industrial Valuation: $ ❑Accessory building El Multi-family Number of bedrooms: ID Master builder El Other: Number of bathrooms: Total number of floors: Job site address: (( , i C�,:TN Ave, New dwelling area: square feet City/State/ZIP: fir-,J C('(22.3 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: _ ••— ��_���_��„����� Covered porch area: square feet Cross street/directions to job site: Z--E•9 LA I C2- .fQL t :' Deck area: square feet Other structure area: square feet Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the work indicated on this application. `PALE AIV- N?Fik S/ r Valuation: $ {/„l �-�l 1�, VP� Existing building area: I W square feet New building area: square feet Number of stories: Name: vv-, LvS:A•s• --` kJk Ck.S Type of construction: Address: )Ss-0 S w N i Les Bow NL J ' Occupancy groups: 1 City/State/ZIP: N 1Lt-S ot_o) c)12.- 9711-3 Existing: Phone:(57)3)tjv$ (-3640 Fax:(513 )(g - (1203 New: 1 BUILDING PERMIT FEES* :: (Please refer to fee schedule) Business name:L_ '�Z.4 t`!F.[,uAi.rl (.'U''"'S7' ��" Structural plan review fee(or deposit): Contact name: j,i,L Cil 1.L FLS plan review fee(if applicable): i Address: (g3Vs S(y..) t_ m - 1l ii - Total fees due upon application: City/State/ZIP:17.ApLA.j,1A.) J 04 ci7e4,L Amount received: Phone:(S-0))2f ie -1JJU I Fax::17,3 )ZJ1.,:?'l/LO E-mail: pc,3 _ •C�'` PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation o roof-top mouhted PhotoVoltaic Solar Panel -m. Business name:L LL ��� Submit two(2)s- of roof plan wit ection details l L.,1-1._ and fire department . cess,a • • with the 2010 Oregon Address: 193 Sw 1'r1_., A„ Solar Installation Spec ••I Code checklist. City/State/ZIP: t_a4 v� 9?OC,z L Permit fe eludes • .n review $180.00 �N y and administrati • ees): Phone:(.3) 2..4 . if I e) l Fax:K-0)u$ (11-0 : .to surcharge(12%of permit fe • $21.60 CCB lie.: f /1 C Total fee due upon application: \ $201.60 1 j,` I Authorized signature:! It/� /I /' , This permit application expires if a permit is not obtained G}. > AJ`c%1/__ within 180 days after it has been accepted as complete. Print name: r V Ul I o Lt.__ Date: I Z-,..,3 ,,,f * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-COM PermitApp.doc 02/24/2011 440-46131(11/02/COM/WEB) 1 r III City of Tigard ■ COMMUNITY DEVELOPMENT DEPARTMENT l_ G K�� Building Permit Review — Commercial - No Land Use Building Permit #: -- 1 cAy) i L-(-OCR 30 473--- Site Address: ? Lo No aJ g SS r v(_ Suite/Bldg#: Project Name: EL.-€t},J Z>Jd}-r t2- l2J tc_F_� (Name of commercial business occupying the space. If vacant,enter Spec Space.) Planning Review Proposal: 1 ns+a,ll new 0.ic Gornpre,sc.c( W4111 n edI sti na ici+erio{ ad' CAAJ-S burVorn -t-r?_.atrn*.rrt pi ant Existing Business Activity: wrist,_rda+eki Proposed Business Activity: same NJ Verify site address/suite#exists and active in permit system. (J Zoning: 'I— p �1 Permitted Use: ❑ Yes No ❑ Spec Space [2 Confirm no land use required. but CWS �5e prey i CAA..A1 Approved �n plan d,str'1*' Notes: e,por} -From awash cal, arch+eca' vef i-ci es comvessof- met-'s noise_ s ordaYQ s o'( Der • 'AVance.C\ V CI.S*- atey' T -.•.ul • a F c.. ' ■ ' •.a b"', IT L.• • %n Tua,_in' are, res- rtc'�iive, Sfa •al.s) Approved by Planning: m f�pQ Date: I `2O I 1 5 N Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Building Permit Submittal Original Submittal Date: Site Plans: # Building Plans: # Building Permit#: ❑ Enter building permit#above. Workflow Routing: ❑ Planning ❑ Permit Coordinator ❑ Building Workflow Sign-off: ❑ Sign-off for Planning(include notes from planning review) Route Application Documents: ❑ Building: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: Date: I:\Bui[ding Worms\BldgPermitRvw_COM_NoLandUse_071514.docx Permit Coordinator Review ❑ Conditions Met-Prior to Issuance of Building Permit Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: ❑ OK to Issue Permit Approved by Permit Coordinator: Date: I:\Bui Iding\Forms\BI dgPermitRvw_COM_NoL andUse_071 5 14.docx RECEIVED s PA ft L I N G JAN 19 2015 W O R K T O G E T H E R I S T A N D a►a N T CITY OF TIGA orandum PLANNINGIENGINE To: Patrick Orr-Clean Water Services From: Adam Bettcher Date: January 15,2015 Subject: CWS-Durham compressor replacement This memorandum concerns the potential noise impact of a proposed replacement air compressor on surrounding properties at the Durham Clean Water Services plant in Tigard, Oregon. The proposed replacement compressor is projected to have noise levels significantly below the noise ordinance's requirements at surrounding properties. Site conditions and project description Clean Water Services'Durham plant is located in Tualatin,Oregon. Surrounding properties include single-family and multifamily residential to the north,light industrial properties to the west and northeast,and an elementary school to the east. Allowable noise levels at adjacent property lines are set by the City of Tualatin municipal code, and are specified separately for'noise sensitive properties'and all other types of properties. Allowable levels on receiving properties are specified in decibels,but do not specify a weighting while A-weighting is implied by the instrumentation required to measure noise levels set forth in section 6.14.110. Allowable noise levels are as follows for nighttime(10PM- 7AM and daytime(7AM-10PM): • Receiving property is noise sensitive:50dBA nighttime,70dBA daytime • Receiving property is not noise sensitive:60dBA nighttime,80dBA daytime The project proposal is to replace an existing compressor in the building with an Atlas Copco GA37SD air compressor with 175psi of working pressure,operating at 60Hz,and using water cooling. Projected levels at property lines At the time of this memorandum,A-weighted sound pressure levels are available from the manufacturer for the compressor,but octave band sound power data and test reports are not available. To determine if the compressor will meet the noise ordinance,maximum allowable sound pressure levels were reverse-calculated from the sound pressure level required by the noise ordinance at each nearby property line. Final A-weighted sound pressure levels for the compressor from the manufacturer were then compared to the reverse-calculated levels to determine the compressor's compliance with the ordinance. Comparison to noise ordinance levels: To provide an estimate of how loud the compressor would have to be to exceed the minimum levels established by the noise ordinance,the maximum 4100 194th St SW•Suite 400,Lynnwood,Washington 98036-4613 206-667-0555 800-667-0610 Fax:206-667-0554 ammw.sparling.com Clean Water Services CWS-Durham compressor replacement statement of impact Page 2 of 2 January 15,2015 allowable unit sound pressure level at lm was calculated for each property line. The results are found in the table below,and can be interpreted as the maximum allowable sound pressure level that the compressor can produce and still comply with the local ordinance. Table 1:Maximum allowable compressor sound pressure levels(1m from source)to comply with noise ordinance requirements at a_djacent property lines. Adjacent/nearby Approximate Ordinance Max Allowable property Distance Direction Level(Lp) Compressor Level(Lp) Office park 485' Northeast 50 dBA 110 dBA Durham Elementary 640' East 40 dBA 103 dBA School Several residential 775' North 40 dBA 104 dBA properties Office park 430' West 50 dBA 109 dBA The compressor's noise levels have been tested according to ISO 2151:2004(Noise test code for compressors and vacuum pumps-Engineering Method,Grade 2)using ISO 9614/2 (Determination of sound power levels of noise sources using sound intensity-Measurement by Scanning). Resulting sound pressure levels one meter from the unit are 67 dBA,according to the manufacturer. Summary of results The projected maximum allowable sound pressure level for the compressor to meet the local noise ordinance was 103dBA. Thus,a compressor with a lower sound pressure level at lm, such as 95dBA,would still comply with the ordinance. The compressor's 67dBA rating is substantially quieter than all the allowable levels described above,and as a result is very likely to meet the local noise ordinance. Please let us know if there are any questions or concerns. ab:filename 1)ebbie Adamski From: Debbie Adamski Sent: Monday, January 12, 2015 9:04 AM To: 'Rob Mitchell' Cc: #CD PoD; Dan Nelson Subject: RE: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Rob, The planning department is waiting for a noise impact report. As of today's date they have not received it. I believe they had spoken with Patrick Orr at Clean Water Services. We need the planning department's approval before we, the building department can complete our review. Debbie Adamski Senior Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd.,Tigard, OR 97223 503-718-2450 From: Rob Mitchell [mailto:rob@ lynch-mech.com] Sent: Friday, January 09, 2015 12:15 PM To: Debbie Adamski Subject: RE: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Hi Debbie, Just checking on permit status. Let me know. Thanks, Rob Mitchell Lynch Mechanical Construction (503)218-1115 desk (503)545-6466 cell rob(alynch-mech.com From: Debbie Adamski [mailto:DEBBIE©tigard-or.gov] Sent: Wednesday, December 24, 2014 6:59 AM To: Rob Mitchell Subject: RE: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Rob, Thanks for the information this is exactly what we needed. I will get this passed on for plan review right away. Have a very Merry Christmas and a Happy New Year! Debbie Adamski Senior Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd., Tigard, OR 97223 503-718-2450 1 From: Rob Mitchell [mailto:rob @lynch-mech.com] Sent: Tuesday, December 23, 2014 4:31 PM To: Debbie Adamski Subject: RE: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Debbie, Attached are compressor submittals and site location drawings. It is not associated with the new construction. Compressor replacement is inside the chemical bldg. far removed from possible neighborhood noise issues and is supplied with noise reducing enclosure. Patrick Orr is Cleanwater Svcs. point of contact (503)547-8014 and is always very helpful. If you need anything else just contact me or Pat. Thanks, Rob Mitchell Lynch Mechanical Construction (503)218-1115 desk (503)545-6466 cell robCa�lynch-mech.com From: Debbie Adamski [mailto:DEBBIE @ tgard-or.gov] Sent: Tuesday, December 23, 2014 4:06 PM To: Rob Mitchell Subject: FW: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Rob, Do you have a site plan showing the proposed location of this air compressor? Is it associated with the building currently under construction, the 0 & M Building? Do you know what the decibel level is of the replacement unit? Our planning department is asking for this information and I need to have it before I can forward the plans to Dan Nelson our building plans examiner. Thanks! Debbie Adamski Senior Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd.,Tigard, OR 97223 503-718-2450 From: Debbie Adamski Sent: Tuesday, December 23, 2014 3:48 PM To: 'rob @lynch-mech.com' Subject: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Rob, Your permit number for a replacement air compressor at the Durham Treatment Plant is BUP2014-00305. We will contact you as soon as the permit is ready to picked up. Debbie Adamski Senior Permit Technician 2 Debbie Adamski From: Rob Mitchell <rob @lynch-mech.com> Sent: Tuesday, December 23, 2014 4:31 PM To: Debbie Adamski Subject: RE: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Attachments: Compressor Submittal combined.pdf; Durham Location Drawing.pdf Debbie, Attached are compressor submittals and site location drawings. It is not associated with the new construction. Compressor replacement is inside the chemical bldg. far removed from possible neighborhood noise issues and is supplied with noise reducing enclosure. Patrick Orr is Cleanwater Svcs. point of contact (503)547-8014 and is always very helpful. If you need anything else just contact me or Pat. Thanks, Rob Mitchell Lynch Mechanical Construction (503)218-1115 desk (503)545-6466 cell rob@lynch-mech.com From: Debbie Adamski [mailto:DEBBIE @tigard-or.gov] Sent: Tuesday, December 23, 2014 4:06 PM To: Rob Mitchell Subject: FW: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Rob, Do you have a site plan showing the proposed location of this air compressor? Is it associated with the building currently under construction, the 0 & M Building? Do you know what the decibel level is of the replacement unit? Our planning department is asking for this information and I need to have it before I can forward the plans to Dan Nelson our building plans examiner. Thanks! Debbie Adamski Senior Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd.,Tigard, OR 97223 503-718-2450 From: Debbie Adamski Sent: Tuesday, December 23, 2014 3:48 PM To: 'rob @lynch-mech.com' Subject: Clean Water Services, 16060 SW 85th Ave, BUP2014-00305 Rob, 1 I 1 Your permit number for a replacement air compressor at the Durham Treatment Plant is BUP2014-00305. We will contact you as soon as the permit is ready to picked up. Debbie Adamski Senior Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd.,Tigard, OR 97223 503-718-2450 DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules "City General Records Retention Schedule." 2 L Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 16060 SW 85TH AVE, TIGARD, OR, 97224 Commercial - Building 299 Final inspection PASS - No C of O BUP2014-00305 Chip Barnett Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 16060 SW 85TH AVE, TIGARD, OR, 97224 Commercial - Building 299 Final inspection PASS - No C of O BUP2014-00305 Chip Barnett Violation Summary: Inspector Contractor