Plans PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-SCALE: NTS MODULE NOTES: TABLE OF CONTENTS
, 1. 7800W DC, 7600W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK) DIMENSIONS:
2. (30) REC SOLAR: REC260PE(BLK) MODULES WITH (1) MAGNETIC TRUE 65.55"x 39.02"x 1.5" PAGE
SOLAREDGE TECHNOLOGIES: SE7600A-US (240V) ARRAY PITCH ORIENTATION ORIENTATION 2. PORTRAIT: CLAMP 8.2"-16.4" FROM EDGE # DESCRIPTION
INVERTER. — py_ 3. LANDSCAPE: CLAMP 0"- 9.8" FROM EDGE
3. TWO STORY COMP SHINGLE ROOF AT 0° PITCH. MODULES AR-01 19° 137° 153° RACKING NOTES: PV 01 SITE PLAN & MECHANICAL
TILTED 19° TO HORIZONTAL. - . 1. SNAPNRACK SERIES 100 OR S100 UL LISTED;
4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT AR-02 19° 137° 153° FLUSH MOUNT L-FOOT. SEE PEN D01. PV-02 ELECTRICAL
RUN PLACEMENT WITH CUSTOMER. -. 2. 8' 0"MAX RAIL SPAN
5. ROOF STRUCTURE: 2X4 ENGINEERED TRUSSES 24"OC. AR-03 16° 227° 243' 3. 2'-8"MAX RAIL END OVERHANG
6. APN#. R0470902 4. LAG SCREWS: 5/16"X 4.0": 2.5" MIN EMBEDMENT
7. CONTACT: TONY CHOY, (503)620-7635 — — 5. RAFTER AND PENETRATION LOCATIONS TO BE
8. DESIGN CRITERIA. DETERMINED IN THE FIELD.
8.1. SYSTEM WEIGHT: 3LBS/SQFT. 6. INSTALLER TO VERIFY RAFTER SIZE, SPACING,
8.2. EFFECTIVE WIND SPEED: 95 MPH 3-SEC GUST. AND UNSUPPORTED SPANS AND NOTIFY E.O.R
8.3. MAX SNOW LOAD: 25 LBS. OF ANY DISCREPANCIES BEFORE PROCEEDING.
SITE PLAN - SCALE: 1/64" = 1' SITE DETAIL ',*I D1 -AR-01 -SCALE = 3/32" = 1-0" I��
0.I
SCALE. 1/16" = 1' 19'-9" RECEIVED
(N)ARRAY AR 03 — r1' lirjv
(E) RESIDENCE ---,, \ 1,-, .II la JAN 0 8 2015
�i TY OF TIGARD
\ (E) PROPERTY LINE \ e__- 0__ 0_ D 0 8"j B. ILDiNG DIVISION
</$J (E) DRIVEWAY 0 cr�rY of TIG °/ /O 93 /O 92 /o J ,, FOR CODE CO
.� ,� \
. Q, oc \ / APP i ��/
FAN \ OTC! i D2 AR-02 SCALE= 3/32" = 1-0"
g�PP pe�i 0I _ 7, • tIDICATES TSRF VALUE AT MARKED LOCATION
Ada� O4 P `D F( 13'-2" -
I $ e• Date: h
7= 0 �'►
' • 10'-11", / ......
(E) SERVICE ENTRANCE 0
(EXTERIOR WALL) \ ' OFFICE COPY '
11111 / O
\ / 82 % 84 % 87 %
7
(N)ARRAY AR-01 D3 -AR-03 -SCALE = 3/32" = 1'-0"
D4- ELEVATION: NTS -. . / �`
!_ (N) ARRAY AR-02 -- _
— (N) INVERTER WITH
6" MAX 16
1'
(E) MAIN PANEL INTEGRATED DC DISCONNECT '-5"— r1'
[_ (..._--.---F—T—___ (INTERIOR WALL)
(INTERIOR WALL) 1
8: '. gi
o
I I I I (- ] I I I �, (N) PV PRODUCTION METER
• 25' (INTERIOR WALL) 10'-11"
21 11' ROOF AREA: 2401.82 SQ.FT.
15' ARRAY AREA 510 SQ.FT. Qa
OVERAGE: 21% 81 00 84 '0
. ��-
SUNRUN, INC. 3380 S E 20TH,PORTLAND OR 97202
sunrun OR CL#180464 PHONE 503-766-4332 DESIGNER: A. WARD SUNRUN PROJECT NUMBER: ' TONY CHOY RESIDENCE SITE PLAN & REV: A
FAX 503-205-0748 TONY CHOY (601R-975CHOY) 10975 SW PATHFINDER WAY, PORTLAND, OR 97223-3930 MECHANICAL PV-01 12/9/2014
DRAFTER: DI
o
LINE DIA 3R ME I EH#:
PGE 24 528 219
UTILITY
GRID SUPPLY SIDE TAP
/ 3
i EXISTING LOCKABLE
C200A MAIN BLADE TYPE SOLAREDGE TECHNOLOGIES: JUNCTION BOX
T BREAKER FUSED SUN RUN SE7600A US (240V) MIN RATED NEMA3R
AC DISCONNECT METER 7600 WATT INVERTER (OR EQUIVALENT) PV MODULES
F EXISTING 3 3 r 2 1 REC SOLAR: REC260PE(BLK)
200A MAIN o�e�-ho d ova--o `�� _ c�-e�o t _ - Iff (30) MODULES ( )
FACILITY PANEL
+ f OPTIMIZERS WIRED IN (1) SERIES
40A FUSES OF (20) OPTIMIZERS AND (1) SERIES
LOADS FACILITY - \ I OF (10) OPTIMIZERS
GROUND SQUARE D 250V METER SOCKET LOAD RATED DC DISCONNECT& SOLAREDGE POWER OPTIMIZER
D222NRB 125A CONTINUOUS& LOAD RATED AC DISCONNECT AND AFCI P300-2NM4ARS
3R, 60A 240V METER
120/240VAC 200A, FORM 2S
NOTES TO INSTALLER: SIGNAGE: '
1. 20 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. CONDUIT SCHEDULE WARNING
2. CONNECT SYSTEM VIA INSULATION PIERCING ON LOAD SIDE OF MAIN WARNING-Dual Power Sources ELECTRIC SHOCK HAZARD
# CONDUIT CONDUCTOR NEUTRAL GROUND Second source is photovoltaic system DO NOT TOUCH TERMINALS
BREAKER IN MAIN PANEL ENCLOSURE. CONDUCTORS ARE FIELD , LABEL PLACEMENT:MAIN PANEL TERMINALS ON BOTH LINE AND
INSTALLED.. 1 NONE (4) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER NEAR METER LOAD SIDES MAY BE ENERGIZED
wARNINC IN THE OPEN POSITION
' IniV,Rrr N 0111,11T CONNECTION CO 11u1
2 3/4" EMT OR EQUIV. (4) 10 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 , •° °°°°ITr^INI..IV I DC VOLTAGE IS ALWAYS PRESENT
LABEL PLACEMENT:AC DISCONNECT. WHEN SOLAR MODULES
3 3/4" EMT OR EQUIV (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 COMBINER BOX,INVERTER ARE EXPOSED TO SUNLIGHT
WARNING-Electric Shock Harare LABEL PLACEMENT:
' No user serviceable pert''ccde /i DC DISCONNECTS
contact authorized service'for assistance
LABEL PLACEMENT:AC DISCONNECT.' WARNING
COMBINER BOX,INVERTER
ELECTRICAL NOTES: CAUTION:SOLAR ELECTRIC ' ELECTRIC SHOCK HAZARD
1, PHOTOVOLTAIC SYSTEM WILL SOLAREDGE SYSTEM NOTES: SYSTEM CONNECTED IF A GROUND FAULT IS INDICATED
OPTIMIZER CHARACTERISTICS 1. SOLAREDGE INVERTER AND OPTIMIZERS ARE LISTED SYSTEM. LABEL PLACEMENT: NORMALLY UNGROUNDED AND ENERGIZED
COMPLY WITH 2011 NEC. CONDUIT,JUNCTION BOXES
2. ELECTRICAL SYSTEM MIN INPUT VOLTAGE 5 VDC 2. STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND MAINTAINED AT 350V DC (NOMINAL).
• 3. STRING VOLTAGE IS ELECTRONICALLY LIMITED BY INVERTER TO 500V DC, MAX. PHOTOVOLTAIC POWER LABEL PLACEMENT
GROUNDING WILL COMPLY WITH MAX INPUT VOLTAGE 55 VDC 4. STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS ELECTRONICALLY LIMITED TO 15A MAX (PER SOURCE NVERTER
2011 NEC. ( LABEL PLACEMENT
3. PHOTOVOLTAIC SYSTEM IS MAX INPUT ISC 10 ADC STRING). CONDUIT.JUNCTION BOXES WARNING
5. SOLAREDGE AC/DC SAFETY SWITCH DISCONNECTS AC POWER AND BOTH POSITIVE AND NEGATIVE DC �ro)�Uevr C��iOAlul1L;'
UNGROUNDED, NO CONDUCTORS ELECTRIC SHOCK HAZARD
ARE SOLIDLY GROUNDED IN THE MAX OUTPUT CURRENT 15 ADC CONDUCTORS AS REQUIRED BY NEC690.35(A). DO NOT TOUCH TERMINALS
LABEL PLACEMENT: TERMINALS ON BOTH LINE AND
INVERTER. SYSTEM COMPLIES ALL DISCONNECTS LOAD SIDES MAY BE ENERGIZED
MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS -INVERTER 1 IN THE OPEN POSITION
WITH 690.35. ,
LABEL PLACEMENT-
4. MODULES CONFORM TO AND ARE AC DISCONNECTS
REC SOLAR: REC260PE(BLK) 260 W SYSTEM SIZE 7800 W
LISTED UNDER UL 1703. ,
5. INVERTER CONFORMS TO AND IS OPEN CIRCUIT VOLTAGE 37.8 V SYSTEM OPEN CIRCUIT VOLTAGE 20 V WARNING
LISTED UNDER UL 1741. OPEN CIRCUIT VOLTAGE: (690.7) 41.1 V SYSTEM OPERATING VOLTAGE 350 V ELECTRIC SHOCK HAZARD
, 6. ARRAY DC CONDUCTORS ARE • THE DC CONDUCTORS OF THIS
SIZED FOR DERATED CURRENT. MAX POWER VOLTAGE 30.7 V MAX ALLOWABLE DC VOLTAGE 500 V PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE ENERGIZED
9.01 AMPS MODULE SHORT '
. CIRCUIT CURRENT. SHORT CIRCUIT CURRENT 9.01 A SYSTEM OPERATING CURRENT 22.3 A LABEL PLACEMENT
14.07 AMPS DERATED SHORT SHORT CIRCUIT CURRENT (690.8(A)(1)) 11.26 A SYSTEM SHORT CIRCUIT CURRENT 30.0 A JUNCTION BOXES,COMBINER BOXES.
CIRCUIT CIRCUIT(690.8 (a) &690.8 DISCONNECTS
LABEL PLACEMENT:AC BREAKER
(b)). (INSIDE OR FRONT OF PANEL)
SUNRUN,INC. 33805E 20TH,P0RTLAND,OR97202 DESIGNER:
sunrun OR CL#180464 PHONE 5037664332 A. WARD SUNRUN PROJECT NUMBER: TONY CHOY RESIDENCE REV:A
FAX 603-2050748
DRAFTER: DI TONY CHOY (601 R-975CHOY) 10975 SW PATHFINDER WAY, PORTLAND, OR 97223-3930 ELECTRICAL PV-02 12/9/2014
0
NOTES: REVISION:
•
- 5/16" LAG BOLTS MUST EMBED
2.5" INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT
- TORQUE ALL 5/16" HARDWARE TO ON TOP OF FLASHING _
SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT
COMPOSITION L FOOT - SILVER S.S. 10-16 FT-LBS
CAN BE MOUNTED IN -
S.S. FLANGE NUT - BLACK S.S. 7-9 FT-LBS STEP 2: SLIP FLASHING OVER
ANY ORIENTATION - RAILS CAN MOUNT TO EITHER SIDE L FOOT BASE AND UNDER ROW
756 X 1" (OR 1.25") OF L FOOT (UPSLOPE VS DOWNSLOPE) >` \. OF SHINGLES ABOVE
SNAPNRACK S.S. BOLT AND
CHANNEL NUT SPLIT WASHER �� , ,�
�� � Vvr:- � �" S.S. LAG SCREW lik
.0P1".44„„„,, WITH FLAT WASHER
SNAPNRACK ' ∎� 2.5 MINIMUM EMBEDMENT
STANDARD RAIL IS STANDARD
SNAPNRACK COMPOSITION ,
ROOF FLASHING STEP 1: BOLT L FOOT
.0 BASE TO ROOF WITH
LAG BOLT
SNAPNRACK L FOOT BASE ROOF DECKING TYP.. iia‘ . 1.,.. __ _>___________ ___------- -----
v.,- ;//' 400001010
ROOF DECKING TP.
FLASHED L FOOT MOUNTING POINT FOR
USE ON COMPOSITION ROOF SURFACES
WITH LOW TO MODERATE TILT
RAILS CAN BE LEVELED UP TO 3" USING
UP TO TWO LEVELING SPACERS AS
SHOWN IN "SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION
RAFTER TYP.
MAINSTREAM ENERGY CORP. DESIGNER: G McPheeters SCALE: DNS PART NUMBER: DESCRIPTION: REV
5napNrack- 775FIERO HO (805)58-970597 S100 PEN D01 PEN DETAIL 01, FLASHED L FOOT TO F PHONE(80554&8705•fAX(805(52&9701 DRAFTER: D Ryan 1_DATE: RAFTER
rA§ U alliP ou'ic ayes ,=7, ,,E€6 /7, nE, ,0 APPROVED BY: 120113