Permit CITY OF TIGARD MASTER PERMIT
III
III I • COMMUNITY DEVELOPMENT Permit#: MST2015-00003
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/22/2015
Parcel: 2S 103AD00805
Jurisdiction: Tigard
Site address: 10975 SW PATHFINDER WAY
Subdivision: PATHFINDER NO.2 Lot: 42
Project: CHOY
Project Description: Solar photovoltaic system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First 0 sf Basement 0 sf Left: 0 Parking Spaces: 0
Height 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $14,600.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Drains: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker 0 Hose Bib: 0 Backwater Value: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: N Other Description: Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
CHOY,TONY SUNYEE SUNRUN INSTALLATION SERVICES INC Required Items and Reports(Conditions)
10975 SW PATHFINDER WAY 3380 SE 20TH AVE
TIGARD,OR 97223 PORTLAND,OR 97202
PHONE: PHONE: 503-501-6377
FAX:
Total Fees: $356.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through OAR 2-001-0r•1. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
Issued By: /■ ` e,,, Permittee Signature:
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application
Residential FOR OFFICE USE ONLY
City of Tigard RECEIVED
Date/B Received b ; �1� Permit No.: r I
r 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
.11111
■ wig : Other Permit:
Phone: 503.718.2439 Fax: 503.598.1960 Plan Date/B R
TIGARD
Inspection Line: 503.639.4175 JAN 0 8 2015 Date Read n�i ®SuSee Pale 2 for
Internet: www.tigard-or.gov Notifi d/Method: ,/ Supplemental Information
CITY OF TIGARD WA,"
:
TYPE OF "i11R. , 8 i REQUIRED DATA:1-AND 2-FAMILY DWELLING
❑New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONS"1'Rl`CTION work indicated on this application.
® 1-and 2-family dwelling CI Commercial/industrial Valuation: $ /11( ���
❑Accessory building [1:1 Multi-family
Number of bedrooms:
❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address:10975 SW Pathfinder Way New dwelling area: square feet
City/State/ZIP:Portland,OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:601R-975C1101/ Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: I Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of a 7.8KW solar photovoltaic system Valuation: $
Existing building area: square feet
New building area: square feet
❑ PROPERTY OWNER ❑ TENANT Number of stories:
Name:Tony Choy Type of construction:
Address:Same as jobsite Occupancy groups:
City/State/ZIP:" Existing:
Phone:(503)620-7635 Fax:( ) New:
❑ APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee schedule)
Business name:Sunrun Installation Services Inc.
Structural plan review fee(or deposit):
Contact name:Evan Fessler
Address:3380 SE 201h AVE FLS plan review fee(if applicable):
Total fees due upon application:
City/State/ZIP:Portland,OR 97202
Phone:(503)880-3549 Fax::( )
Amount received:
E-mail:evan.fessler@sunrunhome.com
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System.
Business name:Same as above Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:" Solar Installation Specialty Code checklist.
City/State/ZIP:" Permit Fee(includes plan review
$180.00
and administrative fees):
Phone:(") Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.:180464 Total fee due upon application: $201.60
Authorized signature: This permit application expires if a permit is not obtained
))) within 180 days after it has been accepted as complete.
Print name:Evan Fessler Date:1/8/15 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 44046131(11/02/COM/WEB)
Electrical Permit Application FOR OFFICE USE ONLY
City of Tigard Received I
l
MIMI
I :oh • 13125 SW Hall Blvd.,Tigard,OR 97CEIVED Plan Review X11 C •
s Phone: 503.718.2439 Fax: 503.598 RE Date/B : Other Permit:
t I c,:\tt , Inspection Line: 503.639.4175 Date Ready/By: ® See Page 2 for
Internet: www.tigard-or.gov JAN 0 8 2015 Notified/Method: Supplemental Information
TYPE OF Wr wQQF TI ARD PLAN REVIEW
❑New construction Additional 7! Please check all that apply(submit 2 sets of plans w/items checked below):
�S�ON ❑Service or feeder 400 amps or more ❑Building over three stories.
❑ Demolition ❑Other: where the available fault current ❑Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings.
less to ground,or exceeds 14,000 ❑Commercial-use agricultural
1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings.
❑Multi-family ❑Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived system.
(),..44,\.(1,‘ ❑Addition of new motor load of ❑"A","E","l-2","1-3",
Job no.: I Job site address: U I') S S W t, of \ ..4 y Six or or more. occupancy.
❑Six or more residential units. ❑Recreational vehicle parks.
City/State/ZIP: ?,0 ak b k� ❑Health-care facilities. ❑Supply voltage for more than
❑Hazardous locations. 600 volts nominal.
Suite/bldg./apt.no.: j Project name: bogy V_ 1-)5 Gwo r ❑Service or feeder 600 amps or more
FEE SCHEDULE
Cross street/directions to job site: Description I Qty. I Fee. I Total I
New residential single-or multi-family dwelling unit.
Includes attached garage.
Subdivision: I Lot no.: 1,000 sq.ft.or less 168.54 4
Tax map/parcel no.: Ea.add'l 500 sq.ft.or portion 33.92 1
Limited energy,residential
75.00 2
DESCRIPTION OF WORK (with above sq.ft.)
` 1 11 r 1r l / L I Limited energy,multi-family
75.00 2
illy+tcM OR a •'6 KW Sc)`:.t! (�-J �2J%/c.,Ikl,( residential(with above sq.ft.)
1 Renewable Energy _ ❑ See Page 2
5 s f-i,: Services or feeders installation,alteration,and/or relocation
❑ PROPERTY' OWNER J ❑ TENANT 200 amps or less 100.70 2
Name: 11 201 amps to 400 amps 133.56 2
TQt 7 C 4noD 401 amps to 600 amps 200.34 2
Address: SGw.C G S J vb St r-( 601 amps to 1,000 amps 301.04 2
Over 1,000 amps or volts 552.26 2
City/State/ZIP: ‘‘ Temporary services or feeders installation,alteration,and/or
Phone:( 59 Oa –)I J 5 I Fax:( ) relocation
v 200 amps or less 59.36 1
Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2
Owner signature: Date: Branch circuits–new,alteration,or extension,per panel
❑ APPLICANT I ❑ CONTACT PERSON A.Fee for branch circuits with
above service or feeder fee,
Business name: ti �1� S t r U' each branch circuit 7.42 2
B.Fee for branch circuits without
Contact name: Vvo, ts5 le r service or feeder fee,first 56.18 2
branch circuit
Address: 33t'd s E AV'E Each add'I branch circuit 7.42 2
City/State/ZIP: Q /�{f O �� Miscellaneous(service or feeder not included)
C/�1 �`Gty 1 Each manufactured or modular
67.84 2
Phone:(
Se.„) ) C –1�p D —��11 1 I Fax::( ) dwelling,service and/or feeder
Reconnect only 67.84 2
E-mail: .e V V,v.- f-r5 S e r@f Suk,,f uv.1nclxv.- i (U1M Pump or irrigation circle 67.84 . 2
CONTRACTOR Sign or outline lighting 67.84 _ 2
Business name: Scy�ti S ���t Signal circuit(s)or limited-energy See
panel,alteration,or extension. Page 2 2
Address: I t Each additional inspection over allowable in any of the above
City/State/ZIP: I 1 Additional inspection(1 hr min) 66.25/hr
•
Investigation(I hr min) 66.25/hr
Phone:( ) ii I Fax:( ) Industrial plant(1 hr min) 78.18/hr
Inspections for which no fee is 90.00/hr
CCB Lic.: 'CO LI 6 L) I Electrical L. 41 Suprv.Lic.: fi/Z?S specifically listed(Y:hr min)
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: /
1C___ ,AI Subtotal:
Print name: ,..'A&* -- S 1.4 r�-e-D Da e: //J. /3— review(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: [ _ -3— TOTAL PERMIT FEE:
CJ 1 ZS , I / (!' / This permit application expires if a permit is not obtained within 180
Print name: G� 5 C Date: / o / days after it has been accepted as complete.
• Number of inspections allowed per permit.
I:\Building e rmits\ELC_PermitApp_ELR_ERE.doc Rev 05/21/2013 440-46t5T(I1/05/COM/WEB
Electrical Permit Application—City of Tigard
,rage 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Fee for all residential systems combined ... $75.00 Description I Qty. I Fee I Total I •
Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva / 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
ElAlarm Wind generation systems in excess of 25 kva:
25.01 to 50 kva 301.04 2
❑ Garage Door Opener* 50.01 to 100 kva 552.26 2
>100 kva(fee in accordance with 552.26 2
111 Heating, Ventilation and Air Conditioning OAR 918-309-0040)
* Solar generation systems in excess of 25 kva:
System
Each additional kva over 25 7,42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
QftSAC tU e v'c''
Each additional inspection over allowable in any of the above:
Other:
Each additional inspection is 66.25/hr I
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed('/:hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Fee for each commercial system $75.00 Subtotal:
(SEE OAR 918-309-0000) Plan review,if required(25%of permit fee):
State surcharge(12%of permit fee):
Check Type of Work Involved: TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
❑ Audio and Stereo Systems days after it has been accepted as complete.
* Number of inspections allowed per permit.
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other
Total number of commercial systems:
*No licenses are required. Licenses are required
for all other installations
L\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 05/21/2013
City of Tigard RECEIVED
Building Division
' en 13125 SW Hall Blvd, Tigard,OR 97223 JAN 08 2015
Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TIGARD
TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 10975 SW Pathfinder Way
City: Portland Zip: 97223
Owner's Name: Tony Choy Date: 1/8/15
Contractor's Name: Sunrun Installation Services CCB #: 180464
Inc.
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation 111 Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than ❑ Yes the prescriptive path.
above
❑ No
I
1:/Building/Forms/Photo Voltaic-Checkli st.docx
•
Is the construction
material wood and does Yes
Type of the construction qualify If"Yes", qualifies for
Construction ❑ No the prescriptive path.
as conventional light
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ® Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. ® If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
Ei
layout in accordance Yes
If"Yes", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
® of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof No
framing or blockin ❑ the prescriptive path.
to the roof g g
directly?
2
1:Building/Forms/PhotoVoltaic-Checklist.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted If the spacing falls
solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60
directly to inches Maximum 60 inches inches,qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
• prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ® Yes the prescriptive path.
surface. ❑ No
I:Building/Forms/PhotoVoltaic-Checklist.docx
r
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing)and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: REC Solar
Model Number: REC 260 PE (BLK)
Listing Agency: UL
4
(:Building/Forms/PhotoVoltaic-Checklist.docx
ENERGIZING LIFE TOGETHER IS)
REC
HIGH PERFORMANCE
SOLAR MODULES
REC PEAK
ENERGY EILK
/11114
REC Peak Energy BLK Series modules are
the perfect choice for building solar
systems that combine long lasting
product quality with reliable power
output. REC combines high quality design
4, 44
and manufacturing standards to produce
high-performance solar modules with
uncompromising quality.
4."4.
41.404.
4.••
MORE POWER ROBUST AND
PER FT' DURABLE DESIGN
etir 43.S41111„,,
414
ENERGY PAYBACK US-PRODUCED
TIME OF ONE YEAR SILICON
, .
, .
- .
/ AL ,
R
RE PEAK ENERGY BLK SERIES
6555:01
1.1 3543 1506 ' r
• �‘„.4-,.....�<b.,•. ..w EFFICIENCY •
-I, -'
IIINTMMINEAR PRODUCT WARRANTY ,
F s YEAR LINEAR POWER OUTPUT
. °1,,11 WARRANTY
0.43 %■°' "
30.00 O
I P.
TEMPERATURE RATINGS
Mounting holes .
+. -I,. Nominal Operating Cell Temperature(NOCT) 45.7°C(-±2°C)
r-• a`
• Temperature Coefficient of PMPP -0.40%/°C
• 4 „ Temperature Coefficient of V°, -0.27%/°C
t. Temperature Coefficient of L, 0.024%/°C
ELECTRICAL DATA @STC REC235PE REC240PE REC245PE REC250PE REC25SPE REC260PE GENERAL DATA
BLK BLK BLK BLK BLK BLK
Cell Type: 60 REC PE multi-crystalline
Nominal Power-P 235 240 245 250 255 260
r4Pa(Wp) _ _ __.. _. ... ___... .. __ .. _.. ._.... .. li 3 strings of 20 cells
Watt Class Sorting-(W) 0/+5 01+5 0/+5 0/+5 0/+5 0/+5 Glass: 1/8"mm solar glass with
Nominal Power Voltage-V,,,p,(V) 29.5 29.7 30.1 30.2 30.5 30.7 anti-reflection surface treatment
Nominal Power Current-Ir, (A) 8.06 8.17 8.23 8.30 8.42 8.50 Back Sheet: Double layer highly resistant polyester
Open CircukVoltage Frame: Anodized aluminium(black)
Va(V) 36.6 36.8 37.1 37.4 37.6 37.8 Junction Box: IP67rated
Short Circuit Current-Ix(A) 8.66 8.75 8.80 8.86 8.95 9.0'
4 bypass diodes
• Module Efficiency(%) 14.2 14.5 14.8 15.1 15.5 15.8 4 mm2 solar cable,35"+47"
Analysed data demonstrates that 99.7%of modules produced have current and voltage tolerance of t3%from nominal values. Hosiden 4 mm2 connectors,MC4 connectable
Values at standard test conditions STC(airmass AM 1.5,irradiance 1000 W/m',cell temperature 25°C).
At low irradiance of 200 W/m'(AM 1.5 and cell temperature 25°C)at least 97%of the STC module efficiency will be achieved.
ELECTRICAL DATA e)NOLi REC23SPE REC240PE REC245PE REC250PE REC255PE REC2nOPE MAXIMUM RATINGS
BLK BLK BLK BLK BLK BLK
Operational Temperature: -40...+80°C
Nominal Power-P,,,(Wp) 179 183 187 189 193 197 p Maximum System Voltage: 600V
Nominal Power Voltage-V,,,.(V) 27.5 27.7 28.1 28.3 28.5 29.0
Design Load: 75.2 Ibs/ft2(3600 Pa)"
Nominal Power Current-1,,,(A) 6.51 6.58 6.64 6.68 6.77 6.81 ii. 33.4 lbs/ft2(1600 Pa)°
Open Circuit Voltage-V,(V) 34.2 34.4 34.7 35.0 35.3 35.7 r `Refer toinstallationmanual
Short Circuit Current-I„(A) 6.96 7.03 7.08 7.12 7.21 7.24 Max Series Fuse Rating: 15A
Nominal cell operating temperature NOCT(800 W/m',AM 1.5,windspeed 1 m/s,ambient temperature 20•C). Max Reverse Current: 15 A
CERTIFICATION WARRANTY MECHANICAL DATA
10 year Product warranty. Dimensions: 65.55 x 39.02 x1.5 in --
c®11S ( E ru ( 25 year linear power output warranty Area: 17.76 ft2
LISTED (max.degression in performance of 0.7%p.a.). Weight: 39.6lbs
UL 1703,IEC 627 i6(ammonia r esi.tance)&IEC 61701
(salt mist corrosion-severity level 6).
Notel Specifications subject to change without notice.
REC is a leading global provider of solar electricity solutions.With nearly two decades of expertise,we offer sustainable,high-
• performing products,services and investment opportunities for the solar and electronics industries.Together with our a REC
partners,we create value by providing solutions that better meet the world's growing electricity needs.Our 2,400 employees
worldwide generated revenues of more than N0K13 billion in 2011,approximately USD 2.4 billion.To see more of what REC can www.recgroup.corin
• offer,visit www.recgroup.com
•
V ,
solar - • • :r CC
LLJ•
SolarEdge Single Phase Inverters
9 9 CSC
For North America W
SE3000A-US / SE3800A-US / SE5000A-US/ SE6000A-US /
SE7600A-US / SE10000A-US / SE11400A-US
2n
s s4 _ •
� t x-
c a ':3c i 4A s
The best choice for SolarEd' bled l
• Integrated arc fault protection(Type 1)for NEC 2013.690.11 oormpliance
• Superior efficiency(98%)
— Small,lightweight and easy to Install on provided bracket
— Built-in module-level monitoring
mr Internet connection through Ethernet or Wireless
— Outdoor and indoor installation
— Fixed voltage inverter,DC/AC conversion only
�► Pre-assembled Safety Switch for faster installation
— Optional—revenue grade data,ANSI C12.1
USA GERMANY ITALY FRANCE JAPAN-CHINA AUSTRALIA THE NETHERLANDS ISRAEL ww■ .solaredge.us
7
• So I a r " . • _ Single Phase Inverters for North America
SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/
SE7600A-US I SE10000A-US I SE11400A-US
SE3000A-US I SE3800A-US SE5000A-US SE6000A-US _SE7600A-US j SE10000A-US 1 SE11400A-US i------
OUTPUT
Nominal AC Power Output 3000 3800 I 5000 6000 1 7600 9980 @ 208V 11400 VA
10000 @240V •
5400 @ 208V ( 10800 @ 208V
Max.AC Power Output 3300 4150 5450 @240V 6000 8350 10950 @240V 12000 VA
•
AC Output Voltage Min:Nom.-Max.111
183-208-229 Vac /
•
AC Output Voltage Min.-Nom:Max 1i1 / i I ✓
211-240-264 Vac
•
AC Frequency Min.-Nom.-Max." 59.3-60-60.5(with HI country setting 57-60-60.5) Hz
24 @ 208V 48 @ 208V f
Max.Continuous Output Current 12.5 16 21 @ 240V 25 I 32 42 @ 240V 1 47.5 A
GFDI Threshold 1 A .�
Utility Monitoring,Islandin1Protection,Country Configurable Thresholds Yes Yes
INPUT
Maximum DC Power(STC) 4050 I 5100 I 6750 ( 8100 I 10250 1- 13500 ( 15350 W
Transformer-less,Ungrounded Yes
Max.Input Voltage 500 Vdc
Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc
Max.Input Current`1 9.5 13 ( 16.5 @ 208V 18 1 23 33 @ 208V 34.5 Adc
15.5 @ 240V ( f 30.5 @ 240V
Max.Input Short Circuit Current 45 _ Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600ko Sensitivity
Maximum Inverter Efficiency 97.7 i 98.2 I 98.3 98.3 I 98 1 98 98 %
( 97.5 @ 208V 97 @ 208V
CEC Weighted Efficiency 97.5 98 98 @ 240V 97.5 97.5 97.5 @ 240V 97.5 %
Nighttime Power Consumption I <2.5 j <4 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional)
Revenue Grade Data,ANSI 02.1 Optionalt;l
Rapid Shutdown-NEC 2014 690.12 Functionality enabled when SolarEdge rapid shutdown kit is installed141
STANDARD COMPLIANCE
Safety U11741,UL1699B,UL1998,CSA 22.2
Grid Connection Standards IEEE1547
Emissions FCC part15 class B
INSTALLATION SPECIFICATIONS _
AC output conduit size/AWG range 3/4"minimum/16-6 AWG j 3/4"minimum/8-3 AWG
DC input conduit size/#of strings/ 3/4"minimum/1-2 strings/
AWG range 3/4"minimum/1-2 strings/16-6 AWG 14-6 AWG
Dimensions with Safety Switch 30.5 x 12.5 x 7.2/775 x 315 x 184 30.5 x 12.5 x 10.5/ in/
.(HxWxD) 775 x 315 x 260 mm _
Weight with Safety Switch 51.2/23.2 l 54.7/24.7 88.4/40.1 lb/kg
Natural
convection
Cooling Natural Convection and internal � Fans(user replaceable)
fan(user
replaceable)
Noise <25 <50 dBA
Min:Max.Operating Temperature
Range -13 to+140/-25 to+60(-40 to+60 version available"') 'F/°C
Protection Rating NEMA 3R
Ul For other regional settings please contact SolarEdge support.
'l'A higher current source may be used;the inverter will limit its input current to the values stated.
!31 Revenue grade inverter P/N:SExxxnA-US000NNR2(for 7600W inverter:5E7600A-U5002NNR21.
' l0j Rapid shutdown kit P/N:5E1000RS0-S1.
`"-40 version P/N:SExxxnA-US000NNU4(for 7600W inverter:SE7600A-U5002NNU4).
ETA [AMil Ro H S
0 SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein
are trademarks of their respective owners.Date:12/2014.V.01.Subject to change without notice.
Location:
Record Type:
Inspection Type:
Result:
Comments:
Inspection Date:
Record ID:
Inspector:
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223 Tel: 503.718.2439
10975 SW PATHFINDER WAY, TIGARD, OR,
97223
Residential - Master Permit
199 Electrical final
PASS
MST2015-00003
Jeff Grove
Violation Summary:
Inspector Contractor
Location:
Record Type:
Inspection Type:
Result:
Comments:
Inspection Date:
Record ID:
Inspector:
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223 Tel: 503.718.2439
10975 SW PATHFINDER WAY, TIGARD, OR,
97223
Residential - Master Permit
299 Final inspection
PASS - No C of O
MST2015-00003
Jeff Grove
Violation Summary:
Inspector Contractor