As requested, we have reviewed the Pipeline Video Reports for the onsite stormwater system
prepared by Pacific Ant-R-Tek dated August 12, 2014, as provided by ESI. The reports indicated
that storm pipes 6, 7, and 49 provide numerous sags, ranging from approximately %4" to over 1 "
(identified as a maximum of 1-V4" by ESI). The pipes in question include: storm pipe 6 located
between manholes 4 and 5, storm pipe 7 located between manholes 5 and 6, and storm pipe 49
located between manholes 53 and 55. All three pipes are designed to be 18" storm lines. Note
that while the video reports indicate that pipes 6 and 7 are 15" diameter, ESI confirmed that those
pipes are in fact 18" diameter per the design drawings (see attached).
The design slope for storm pipes 6 and 7 was 0.46% and 0.47%, respectively. The as-built slopes
as measured by Kerr construction are 0.47°/a for pipe 6, and 0.53% for pipe 7. Both as-built
slopes exceed the design slope. The design slope for storm pipe 49 was 0.50%. The as-built
slope measured by Kerr Construction is 0.45%. While this is slightly less than the design slope, it
is within allowable limits and will still accommodate the design conveyance rate.
Bellies within a storm pipe have the potential to lead to increased sediment accumulation in the
bottom of the pipe. This in turn could require additional maintenance to clean the pipe to
maintain adequate flows. However, in this case, even if sediment accumulated in the
approximate 1-3/4" belly of the pipe, the remaining pipe section and overall pipe slope would still
provide sufficient flows to convey the design storm. In addition, we understand the Walmart
Construction Manager has accepted the bellies as constructed.
20 GI.- O 00?(j
76-co r -i -1.t k Yr
, Page 2 of 2
Heath Wyckoff
January 8, 2015
Based on the above information, it is our opinion that the storm pipes will meet the design
requirements to convey the required hydraulic flow rate of the design storm event.
cc: Jeffrey Diehl; Engineered Structures, Inc.
Eric Evenson; Wal-Mart Stores, Inc.
BD:rs
Attachments
tiw3hwmm0l
20-001-091 51
.' ,) i) i
. 1 3
1 4
L, I I I
. .
i i
-1
LEGEND / / \ '
. i (...........ikt..\\x.t 182 R2
.
/ '47.."•••••
,.‘ DOSING CONTOUR I • / 15'PORK
PROPOSED CONTOUR / :>••..4:,;y0‘ =I a
STANDARD STORM MAN1101./ IA / ,
' 41'
STANDARD aim CUT
1 11./
STANDARD CATOISASIN • /
STORK WAN PIPE
/ / 7,1 *?..' .
10, ,11031,_
4, ..,...„...
RIP-RAP APRON . / •
INTERCEPTOR DRAW --.—..-- I . . i i , it........,., , , r PERFORATED PPE INDI DA soFt. / LSIMInTei
;T • 1. • r SDI CO
<
POND NTERCEPTCR DRAIN--4--P.-
/ / I '
1 '' 11 7, -:: . ClIDECCED N ORAN ROM MIR 10 1 MN PR3.50i
'...-- \ RE1M•10 WALL PLANS ....42E.18027 .. I E 1..80...72
.I.. . ..■•=.. ••••■•■•••
, $ J
•
(91 \•=f....--..---.--==.--..—..—.....—..
/ ' / / •
i I ■ i•i
/ .
. [
. A: to
.. ...,.. .__
r SD EAMON
le SS XP 17756
, , 1 1 4..'‘ I
/
; / . ,",°••■....;:\..... 0.. Y.
f e ; 1 . , .:. ,
/
i .c- / i' I
1/ .:
Iii 'I FIFTA1L II 11 rra
_._
i 0 ; 0 12SICO Si A
/ I 1,I P R•las ..-c SW CO x.
/ , g /r 1 \ _II ...:, il 51 RIR MA
1 ,- 4...Win i
1
/ s i ,
i (21111.11112 i ', ll I / ii.. f---- • . 4- r=i-----./- r=.
,
I /
I-) / // l'o II I
t\'
I ' I I--) /
) 1 ■ .$ lf SD 1E177.03
(SS TOP me i -...) ,
i
/ /
i ':'''. L__ Ill 10 1 1 / : 0 4
I / - ilb al, a _i ,_. a ' IVE 1111:1(
UNTERSTAB DRAWL TRIED- ..— - .....
REFER to 0-3.0 AND D-33. i,'04,,,,,./2"....0 r IT
-.' - ,/n,a' ' . i
' ...,' -Pa
99t-LW mo awe I i I : /*".... ,.." -,-',-,'..... .
DIFICARIENT PIAN/ `. is"Ittimie .*.
ir ss Tim 171.36 r • 1 r -14N-
-
I- . ,3* --: , ''," 7,0' A .7.7.-117--1- -- 1 , r ss Ix 17642
i -- ,
l'w la STORM PIPE 7
, „.. _ pkvosio ow ROCARD POW ,
1 . . INIEVOSIER STIRIN1ECT1 IIC-3500%RES FAIR,LA'ON 10 CARTRIDGES
/ ,•:
UNIOICROM otr(11101 S1S101 (61ASHE(T C-63) (3 li II
/ , :.i i
r ,1.,.,!,
. I (SEE SKIT 1.-li)
CI_____..., I, _j 1.—_ --t...............--• r SO 1E17551 ,/1) e DOW
IE 177.1207”
/
--- .....:
r------.......„--- r ss ice 17025 ' D
Hi 4.CNOPTIIRUS iniramouli
{
/
/1 / II
, ?,,.
I
I 1
( II • :,ii mom
meounui mmmmmm•I
--,...- i OPP e:177.011 inn
UM..
,1 1' i\
i t 1
/
ti I .., t".1".; MIN .
/ a
r r . 7 1110 , STORM PIPE 6
STORM
Fri
0
/ # ,i ; it 13),,w
,, , . v. .n.......1 .,. ..----PIKIPOSED OW I
/ , 0 :-...0 NI FILIElt-INANW7 1
i I - 1 •
..t ww...... --., •-• ,-, :. . . 1
C / 1016 48-Sd 166.63
SS ICIP 16141 \•:::- 111.SD4E WM
------ 6*SS r . .
. ...
• IW:-46." ' r--117-7r\-1
. _
m . _-
. ,
, . . . \
/If vest 7(5 1 ',.• ,. '611" , i, 15•SD IE.170.12. ` FRE-OA
If SO IL 4. r SI it liLle FEMORA
"MD e .ir .41 .. (----.. .
-_____ ■
///:- ...:.z,....N.......„.
111'
N.%1. 't 4..
, •
•
H ///
it\- •..--,- 6 i
,
.r. ,
/— /------------,13, s \
/ \ -
I 9i ti ‘,4: it \11. \
\ 1
\ .
,
- iii'''1/ I LoccRstAB
.i
... / \ 1
"" /.7.-------''\ - u::'::-:-, •*N' 12.000 sri I 7 -
%. ,,---.1.•, \ FIE•176 Igt
— •-•. ill III' E in 00(TW)
E.
V r siii co
`,‘ ; All 17525
1 1 E 171.711 t 10 \ '441111 1._ J il 1 E 17561
PREZ+
6
a ___Nss:- /\:./. ,JA ) ) k \ 0 ....... . ill
I . ,i-
1
- ''...............\.. _/r,..,,...N \ `.„.s
._ --\,d, ----:: ----.'- .4111Mrng"ONIUMMi " --
a \ `.... y. ', ...-
.
E , — - .--/".----
?•1 j •
----- .
..g. , s.
.. ........■.,....■.=...mom■■.LN.N.■..,■ik.■.. ...■■ . .. • .. ■•■••••?..7—■.—..---"--“ .•...■•■•=i1INMErn-■...ENRIIII
P MOM DRAM DiSOORCE 10
---
S. 811 ......,E 091 06'FRP RAP ' OuWALT f 36610
UPI MICRON aSTAit 600 CUSS 100
g ••■.t.::;,V1;-:.. sa ARDI PLANS FOR/COMO
ORAN 1.0CATICNS. RVRAP PAD Al OUTFAU.
,i,-
41 Know what's below.
...% - Call before you dig.
No. Date By Revision Description Deakined By: Issue Date: ,oto PRorcvs>
IASB 3/18/13 701391PE r
Drawn By: Issue: --' A
i AISB/NCS OTB OREGON - C:1
15 Checked By: Project No. MM■
6O SE LAW Road
.....'
0: SN 20- 12/31/IA
001-091 SuRe 300
Portland,OR 97222
NNENS
•
PACIFIC INT-R-TEK PACIFIC INT-R-TEK Mobile: 503-730-4343
A Division of Scott Pipeline Video. Inc. Office: 503-665-1090
2501 NW Division St PIPELINE VIDEO REPORT Fax:503-665-1160
Gresham,OR 97030
OR CCB#146869,WA PACIFI*991CW
__- Customer - Project _ Media Label
-- — Kerr Walmart 9508
-
Location/Street Survyor Report# _
__ _. ON SITE Kevin Odermann
Upstream ID Downstream ID _ -- Camera Direction - Date Time
SHEET C-2.5 NOTE 55 -• SHEET C-2.5 NOTE 53 Downstream 08-12-14_j1 4:20 PM
Pipe Size _ Pipe Type Sewer Use Purpose Length TV'd
18 - HDPE Storm Ting 192
Comments Reference Ball__
ON SITE STORM — 1" Ref. Ball With Wet Lines
Ftg. Code Description Position Severity Comment
iifill •0.0 MH Manhole SHEET C-2.5 NOTE 55
V
'46.4 G Break in Grade(Sag) 3/8 INCH OF WATER
i
rir
°85.6 0 Break in Grade(Sag._ 3/4 INCH OF WATER
tie\S._
125.5 G Break in Grade(Sag) 3/8 INCH OF WATER
- 125.8 SL Service Left 9
126.4 G Break in Grade(Sag) 1 INCH OF WATER
127.3 G Break in Grade(Sag) 1 INCH+OF WATER
132.4 G Break in Grade(Sag) 3/8 INCH OF WATER
138.2 G Break in Grade(Sag) 3/8 INCH OF WATER
138.7 G Break in Grade(Sag) 7/8 INCH OF WATER
139.6 G Break in Grade(Sag) 114 INCH OF WATER
151.8 G Break in Grade(Sag) 3/8 INCH OF WATER
153.0 G Break in Grade(Sag) 7/8 INCH OF WATER
• ?,'-157.7 G Break in Grade(Sag) 3/8 INCH OF WATER
- 159.8 SR Service Right 3
162.9 G Break in Grade(Sag) 3/8 INCH OF WATER
°171.8 G Break in Grade(Sag) 7/8 INCH OF WATER
- —173.1 G Break in Grade(Sag) 3/8 INCH OF WATER
'185.3 G Break in Grade(Sag) 3/8 INCH OF WATER
187.1 G Break in Grade(Sag) 1 INCH OF WATER
187.9 G Break in Grade(Sag) IJNCH+OF WATER,
191.3 G Break in Grade(Sag) 1/4 INCH OF WATER
192.0 MH Manhole SHEET C-2.5 NOTE 53
Generated on Tuesday,8/12/2014 at 04:39 PM by the PipeTech®TV inspection system.
PACIFIC INT-R-TEK PACIFIC INT-R-TEK Mobile: 503-730-4343
A Division of Scott Pipeline Video, Inc. Office: 503-665-1090
2501 NW Division St PIPELINE VIDEO REPORT Fax: 503-665-1160
Gresham,OR 97030
OR CCB# 146869,WA PACIFI'991CW
Customer Project Media Label
- _ Kerr_ - Waimart 9508
r--- _ _ Location/Street Surveyor Report# _
i ON SITE Kevin Odermann
Upstream ID - Downstream ID Camera Direction Date' Time
SHEET C-2.5 NOTE 5 J ' SHEET C-2.5 NOTE 4 . Downstrea t 08-12-14-11 2:30 PM
Pipe Size Pipe Type _ Sewer Use (,Purpose Length TV'd
15 � ! HDPE __-J Storm .Testing 142 _
Comments Reference Ball
ON SITE STORM i_ 1" Ref. Ball With Wet Lines
Ftg. Code Description Position Severity Comment
0.0 h1H Manhole SHEET C-2.5 NOTE 5
1(
40.2 G Break in Grade(Sag) 114 INCH OF WATER
54.8 G Break in Grade(Sag) 3/8 INCH OF WATER
- 62.2 G Break in Grade(Sag) 1/4 INCH OF WATER
71.1 G Break in Grade(Sag) 1 INCH OF WATER
73.4 G Break in Grade(Sag) 1 INCH+OF WgIFR
V 82.5 G Break in Grade(Sag) 1/4 INCH OF WATER
85.5 G Break in Grade(Sag) 1 INCH OF WATER
88.1 G Break in Grade(Sag) 1 It _E +nF I T R
108.0 G Break in Grade(Sag) 3/8 INCH OF WATER
111.6 G Break in Grade(Sag) 1 INCH OF WATER
113.4 G Break in Grade(Sag) 1 INCH+OF WATER
117.5 G Break in Grade(Sag) 3/8 INCH OF WATER
=119.4 G Break in Grade(Sag) 1 INCH OF WATER
121.0 G Break in Grade(Sag) 1 ttA(`.H+r■F WATER
129.8 G Break in Grade(Sag) 3/8 INCH OF WATER
142.0 MH Manhole SHEET C-2.5 NOTE 4
Generated on Tuesday,8/12/2014 at 03:35 PM by the PipeTech®TV inspection system.
PACIFIC INT-R-TEK PACIFIC INT-R-TEK Mobile: 503-730-4343
A Division of Scott Pipeline Video, Inc. Office: 503-665-1090
2501 NW Division St PIPELINE VIDEO REPORT Fax: 503-665-1160
Gresham.OR 97030
OR CCB#146869.WA PACIFI*991CW
Customer Project Media Label
Kerr — _ —_-- -- -- Walmart 9508 _
Location/Street Surveyor Report#
ON SITE Kevin Odermann —_. _
Upstream ID Downstream ID _ Camera Direction Date Time
SHEET C-2.5 NOTE 6 ] 1 SHEET C-2.5 NOTE 5 r Downstream 08-12-14 _II_ 3:15 PM
Pipe Size Pipe Type Sewer Use Purpose __ Length TV_'d _
)
15 _ _HDPE . Storm Testing_ 70
Comments ____ __ Reference Ball
j ___- ON SITE STORM 1"Ref. Ball With Wet Lines !
Ag. Code Description Position Severity Comment
•0.0 MH Manhole SHEET C-2.5 NOTE 6
ink
6.5 G Break in Grade(Sag) 1/2 INCH OF WATER
8.6 G Break in Grade(Sag) 1 INCH OF WATER
10.5 G Break in Grade(Sag) 1 INCH +OF WATER
1 trc
,. ',." :.,,) .-.' --''1" ' 17
35.4 G Break in Grade(Sag) 5/8 INCH OF WATER
Pi
V 39.5 G Break in Grade(Sag) 1 INCH OF WATER
45.9 G Break in Grade(Sag) 3/8 INCH OF WATER
3
51.8 G Break in Grade(Sag) 7/8 INCH OF WATER
53.7 G Break in Grade(Sag) 1 INCH OF WATER
55.4 G Break in Grade(Sag) 1 INCH+OF WATER
58.5 G Break in Grade(Sag) 3/8 INCH OF WATER
°70.0 MH Manhole SHEET C-2.5 NOTE 5
Generated on Tuesday,8/12/2014 at 03:30 PM by the PipeTech®TV inspection system.
Bryan Dickerson
From: Tyson Corcoran <tcorcoran @KERRCONTRACTORS.COM>
Sent: Wednesday, December 31, 2014 10:13 AM
To: Shawn Nguy; Matthew Pierce; Heath Wyckoff; Bryan Dickerson
Cc: Eric Evenson (Eric.Evenson @walmart.com); Jeffrey Diehl; Eric Jeter
Subject: RE:WM 5935 Tigard - Storm water pipe flow certifications of concern
Shawn,
The grade differential between manholes 53 and 55 is 0.87'.
Tyson Corcoran
Kerr Contractors
tcorcoran @kerrcontractors.com
503-504-9055
From: Shawn Nguy [mailto:snguy @pacland.com]
Sent: Tuesday, December 30, 2014 10:27 AM
To: Matthew Pierce; Heath Wyckoff; Bryan Dickerson; Tyson Corcoran
Cc: Eric Evenson (Eric.Evenson @walmart.com); Jeffrey Diehl; Eric Jeter
Subject: RE: WM 5935 Tigard - Storm water pipe flow certifications of concern
Matthew/Health —
The map provided also showed sags in the pipe between MH 53 and 55. Please provide the grade differential
between these two manholes as well.
0 le
•,,k
ilcz,k
-1•o•111•111111=1 ■.aaaa. as
�--�
6- STN co 18 SD (174.66
Rik 179.60 6' SS TOP 17132
Ii:: 175.28 !
Shawn Nguy, P.E.
PACLAND
Engineering&Development Consulting Services
1
6400 SE Lake Rd,Suite 300 I Portland,OR 97222
Office:(503)659-9500 x1318 I Fax:(503)659-2227
From: Matthew Pierce [mailto:mpierce(TKERRCONTRACTORS.COM]
Sent: Wednesday, December 24, 2014 9:31 AM
To: Heath Wyckoff; Bryan Dickerson; Shawn Nguy;Tyson Corcoran
Cc: Jeffrey Diehl; Eric Jeter
Subject: RE: WM 5935 Tigard - Storm water pipe flow certifications of concern
Good morning. We set up a rotary laser and shot the in/out elevations on manholes 4,5, and 6. Between
manholes 4 and 5 there is .66' of grade differential at the ie.'s. There is .38' of fall between manholes 5 and 6.
The design plans list these as .67'and .33' respectively. We didn't have a good point to use for a bench mark, so
I dont have actual elevations. We could have used the slab of retail 2, but the parking lot was crowded, and we
would have had to transfer grades several times. Let me know if this works,thanks.
Sent from my Verizon Wireless 4G LTE Tablet
Original message
From: Heath Wyckoff<HeathWyckoff @,esiconstruction.com>
Date: 12/24/2014 8:02 AM(GMT-08:00)
To: Bryan Dickerson<bdickerson@pacland.com>,Shawn Nguy <snguy@pacland.com>,Tyson Corcoran
<tcorcoran@KERRCONTRACTORS.COM>,Matthew Pierce <mpierce @KERRCONTRACTORS.COM>
Cc: Jeffrey Diehl<jeffreydiehl @esiconstruction.com>,Eric Jeter<eieter(&,pacland.com>
Subject: RE: WM 5935 Tigard- Storm water pipe flow certifications of concern
Matt,Tyson
Russell called me yesterday and told me he had the I.E numbers, please get this information to Pacland ASAP so we can
get this last issue resolved and get C of 0.
Thank you in advance
Heath Wyckoff
(208)401-8332
heathwyckoff @esiconstruction.com
From: Heath Wyckoff
Sent: Monday, December 22, 2014 10:34 AM
To:'Bryan Dickerson';Shawn Nguy; 'Tyson Corcoran'; Matthew Pierce
Cc:Jeffrey Diehl; Eric Evenson; Eric Jeter
Subject: RE: WM 5935 Tigard-Storm water pipe flow certifications of concern
Tyson, Matt
Please see email below, and please provide the requested elevations.
2
Thank you in advance
Heath Wyckoff
(208)401-8332
heathwyckoff @esiconstruction.com
From: Bryan Dickerson [mailto:bdickerson @pacland.com]
Sent: Monday, December 22, 2014 10:30 AM
To: Heath Wyckoff; Shawn Nguy
Cc:Jeffrey Diehl; Eric Evenson; Eric Jeter
Subject: RE: WM 5935 Tigard -Storm water pipe flow certifications of concern
Heath —did you shoot as-built elevations for the pipe inverts at the manholes for the pipes in question? Given
the depth of standing water in some of the sag sections, it would be good to confirm the overall pipe
slope. Let me know if you can provide that.
Thanks,
Bryan Dickerson, P.E.
PAC LAND
Engineering&Development Consulting Services
6400 SE Lake Rd,Suite 300 I Portland.OR 97222
Office.(503)659-9500 x1314 I Fax:(503)659-2227
From: Heath Wyckoff[mailto:HeathWyckoff @esiconstruction.com]
Sent: Monday, December 22, 2014 9:23 AM
To: Bryan Dickerson; Shawn Nguy
Cc:Jeffrey Diehl; Eric Evenson; Eric Jeter
Subject: RE: WM 5935 Tigard -Storm water pipe flow certifications of concern
Bryan,
Thank you,just to let you know until this issue is resolved we won't be able to get C of 0..
Thank you in advance
Heath Wyckoff
(208)401-8332
heathwyckoff @esiconstruction.com
From: Bryan Dickerson [mailto:bdickerson @ pacland.com]
Sent: Monday, December 22, 2014 9:20 AM
To: Heath Wyckoff; Shawn Nguy
Cc:Jeffrey Diehl; Eric Evenson; Eric Jeter
Subject: RE: WM 5935 Tigard -Storm water pipe flow certifications of concern
Heath — I received the files you sent and will take a look at them to confirm everything looks okay. I'll try to
get back to you on this later today.
3
Thanks,
Bryan Dickerson, P.E.
PACLAND
Engineering S Development Consulting Services
6400 SE Lake Rd,Suite 300 I Portland,OR 97222
Office:(503)659-9500 x1314 I Fax:(503)659-2227
From: Heath Wyckoff[mailto:HeathWyckoff @esiconstruction.com]
Sent: Monday, December 22, 2014 8:44 AM
To: Bryan Dickerson;Shawn Nguy
Cc:Jeffrey Diehl; Eric Evenson
Subject: FW: WM 5935 Tigard-Storm water pipe flow certifications of concern
Pacland,
Here is the email that the city is requesting the wet stamp.
Thank you in advance
Heath Wyckoff
(208)401-8332
heathwvckoff @esiconstruction.com
From:Jeffrey Diehl [mailto:leffreydiehl @esiconstruction.com]
Sent:Tuesday,September 16, 2014 3:33 PM
To:Joel Jenson;Tyson Corcoran
Subject: FW: WM 5935 Tigard -Storm water pipe flow certifications of concern
FYI.
Jeffrey Diehl
Senior Project Manager
Engineered Structures, Inc.
3330 East Louise Drive, Suite 300
Meridian, ID 83642
(208) 362-3040 Office
(208) 362-3113 Fax
"Experience...Service...lntegrity!"
From: Eric Evenson [mailto:Eric.Evenson@walmart.com]
Sent:Tuesday, September 16, 2014 4:25 PM
To:Jeffrey Diehl
Cc:Guy McLain
Subject: RE:WM 5935 Tigard-Storm water pipe flow certifications of concern
Jeffery
4
This is not outside of acceptable tolerances and I will accept this as is.
Eric
From: Jeffrey Diehl [mailto:jeffreydiehl @esiconstruction.com]
Sent: Tuesday, September 16, 2014 10:48 AM
To: Eric Evenson
Cc: Jeffrey Diehl; Guy McLain
Subject: WM 5935 Tigard - Storm water pipe flow certifications of concern
Eric,
Per our conversation today, attached is a map of the onsite storm water pipe system. Per the attached certification
reports,there are a couple of portions noted on the map that exceed the allowable 1"sag by approximately 1/8"to
'/<". As we discussed, it is not expected this deflection will in any way compromise the functionality of the system. We
are prepared to make these repairs but it will require cutting into the asphalt. Given the quality of the asphalt paving,
the minimal deflection may not be enough of a concern to justify creating asphalt patches in the new parking lot.
Please review and let me know how you would like us to proceed. Thanks.
Jeffrey Diehl
Senior Project Manager
Engineered Structures, Inc.
3330 East Louise Drive, Suite 300
Meridian, ID 83642
(208) 362-3040 Office
(208) 362-3113 Fax
"Experience...Service...Integrity!"
This email and any files transmitted with it are confidential and intended solely for the individual or entity to
whom they are addressed. If you have received this email in error destroy it immediately. *** Walmart
Confidential ***
!SIG:5498634519115372248344!
5
CONFIRMATION OF 18" PIPE DIAMETER AT MANHOLE 6
.5 .fir
41,A 1,, t
! ' r 1 • f• �•�
•
C-r 41
•
•
d
MCI% r ..
•
RECEIVED
JAN 13 2015
CITY OF BUILDING DIVISRD
ON