Permit CITY OF TIGARD MECHANICAL PERMIT s COMMUNITY DEVELOPMENT Permit#: MEC2015 00017 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/15/2015 Parcel: 2S102AB03100 Jurisdiction: Tigard Site address: 12425 SW MAIN ST Project: Sheri's Jewelry Box Subdivision:E LECTRIC ADDITION TO TIGARDVILLE Lot: 4 Project Description: Replacing(2)furnaces with(1)furnace,and relocating the new furnace to an existing closet space. Contractor: SPECIALTY HEATING&COOLING INC Owner: CHRISMAN FAMILY TRUST 7500 SW TECH CENTER DR STE 130 CHRISMAN, RICHARD& HEATHER TRS TIGARD, OR 97223 172 MIDDLECREST RD LAKE OSWEGO, OR 97034 PHONE: 503-620-5643 PHONE: FAX: 503-681-0793 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 01/15/2015 $347.71 Class of Work: ALT Type of Const: Plan Review 01/15/2015 $86.93 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 01/15/2015 $41.73 Stories: Info Process/Archiving-Sm$0.50(up to 01/15/2015 $2.00 11x17) Project Valuation: $9,951.54 Fuel Air Handlers Fuel Types: Units<10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 1 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $478.37 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.3 Issued By: • ittee Signature: 4110111 -- J Call 503.. .• by 7:00 a.m.for the next available inspectiod te. This permit card shall be kept in a conspicuous place on the job site until com etion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FOR OFFICE USE ONLY Cl of Tigard Ctli-Nt Received Permit No.: ,IN . `5 g Date/By: .1� �►'1 _ 0 1• 1 3125 SW Hall Blvd.,Tigard,OR 972 Plan Review Phone: 503.718.2439 Fax: 503.598.1'1t Date/By: Other Permit: T I CiARD Inspection Line: 503.639.4175 , ( \J Date Ready/By: Juris: ® See Page 2 for Internet: www.tigard-or.gov Sib 16 Notified/Method: Supplemental Information Mechanical permit fees*are based on the value of the work ❑ New construction g Addition/alter performed.Indicate the value(rounded to the nearest dollar)of all ❑ Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ ti a s) .5li ESIDENTIAL F UIPME' ❑ I-and 2-family dwelling ®Commercial/industrial El Accessory building For special information use checklist. ❑ Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total E INRM.ATION 41FriDCATIONAMEIMIE Heating/cooling: Air conditioning 46.75 Job site address:iZ y i S SW m Ai(1 ST Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: T;yr r o R. 9 722.3 Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: 1 Project name:SC hef t 5 _ n Heat pump 61.06 �ew)ef y Qo Duct work 23.32 Cross street/directions to job site: on ,n ST rveXT 7C7 Ccuf tn/a 54- Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 + . n 1.x , Gas replacelinsert 0 ¢ . ' : ? ' a' ;' ,4t L'rk ;"n [ ' 33.39 $. 11Ji. .4,414',ek.F`.m Y.� v,v .,.. . h ,,,aymk ,tt.ri_:,G.,-,A .N sj1. Judba.0 r,fi . t Flue vent for water heater or gas keP/c. ne %W c Dec,e1 /Jvfit- SV.57rNIS t );T-L, o;. e fireplace 23.32 Log lighter(gas) 23.32 12c /occ.Te AJfnoce 111729 SPc,ce laSTer~e( of o1)(-1P( Wood/pellet stove 33.39 1)0 hI E 1T Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 € = ' C,',,,.c,, ''IAN''; I ''''h, ' Environmental exhaust and ventilation: Name: 17,<4(... kec-.fl e C 4 f iSN+o /1 Range hood other kitchen Address: nn nn equipment 33.39 71 ms,d.�ce G/CS 1 KD Clothes dryer exhaust 33.39 City/State/ZIP:Lc_re QStnie O , O f-. 970 34-1 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(So 3 ) 62J Op-3 S Fax:( ) Attic/crawlspace fans 23.32 ar r,:1 .. ■N `v ri• '°❑ CONTACT PERSON', Other: 23.32• Fuel piping: Business name: $14.15 for first four;$4.03 for each additional Contact name: Furnace,etc. Address: Gas heat pump Wall/suspended/unit heater City/State/ZIP: Water heater Phone:( ) I Fax::( ) Fireplace Range E-mail: Barbecue Clothes dryer(gas) �f Other: Business name:SQeei0.?Ty IrP�TiA) a t�001`A Address:7500 Sw Teci, Le nt--e r 0 r. Svc'e C30 Subtotal City/State/ZIP: ier.A. 0 . 97 z z 3 Minimum permit fee($90.00) ' Plan review(25%of permit fee) Phone:( Q3 ) Z.O - 56 t-I? Fax:( ) 6 State surcharge(12%of permit fee) CCBlie.: 66S78 TOTAL PERMIT FEE 1-4-,8d 37 This permit application expires if a permit is not obtained within 180 _..) days after it has been accepted as complete. Authorized signature: '- * Fee methodology set by Tri-County Building Industry Service Board Print name:Grea. -7 / . Date: j--)5 - I S I.Building Permits MF('TermilApp_040113.doc 440-46171(11 02 COM WEB) , VAV ,,,i SITE •L.A N `, RECEIVED PL vmen�'G crawl Sc JAN"15 2015 1 i - ✓h-c toco-1`eq, l,, ,JAN-1 TY FT1GARll '.i B 1LD G DIVISION ./nc Sir g, Q-Von-I- -011(9,4 it S,o% .-- 100 8p�� /A�/ itVI1. PL V Lc�}c� poi PL __ y...___ itiu Duci 1,,,�r K R7Lrn All- (A)` II Ile Pvrt i'1 [10(,\J Rd,ll Cre.&11_ SQ�ct Ate; nw,-n, ezL;S►,�^J P;P*. PL STREET m r , ..iii* NOTE — Please show the following on the site plan: •:• Location of Indoor Unit and Outdoor Unit •:• Indicate how the flue will be run (thru the roof— out the sidewall —etc) Indicate with dotted line how the lineset will be run and approx. distance Indicate how the condensate will be run 7500 SW Tech Center Drive Specialty Suite#130 Tigard, OR. 97223 HEATING&COOLING INC. (503)620-5643 Fax:(503)681-0793 WWW.sDecpRlltvhpaiina rnn, 58STA/STX 4-Way Multipoise Induced-Combustion Gas Furnace Card le� Input Capacities: 45,000 thru 155,000 Btuh Turn to the Experts. Product Data THE CARRIER 58STA/STX GAS FURNACE The 58STA/STX 4-way Multipoise Gas Furnaces feature Carrier's e"' . e"••"""■, QuieTechTM noise reduction system ��r•••'•••••\ for incredibly quiet induced draft �� operation. Applications are easy with yy 4-way multipoise design, through- the-furnace��� the-furnace downflow venting, 13 dif- easw"'"■, f.'""""•■••, ferent venting options, and a door e designed for easy service access. An ,•••"•••, inner blower door is provided for © � ��,� ��� tighter sealing in sensitive applica- tions. The 58STA/STX furnaces are e""'"'"•••„f•••'••■, approved for use with natural or pro- pane gas, and the 58STX is approved for use in Low NOx Air Management Districts. STANDARD FEATURES - QuieTechTM system noise reduc- tion system — Microprocessor based control center LED diagnostics and self test feature Adjustable heating air temperature rise Adjustable cooling airflow — 4-way Multipoise furnace, 13 vent applications — Compact design — only 33-1/3 in. tall - Power HeatTM Igniter — Draft safeguard switch to ensure proper furnace venting — Inner door for tighter sealing — Hybrid HeatTM compatible — All models are chimney friendly when used with accessory vent kit — Twinning in Upflow, Downflow and Horizontal — Residential installations eligible for consumer financing through the Retail Credit Program A04039 LIMITED WARRANTY — 20-year warranty on "Super STM" heat exchanger — 5-year parts warranty on all other components CNPVP, CNRVP, CNPVT, CNRVT, CNPVU, CNRVU Evaporator Coil aarY[er N Coil — Cased and Uncased Upflow, Downflow Turn to the Experts. Product Data This vertical design N-coil is a furnace coil designed to provide the highest standards of reliability and durability. The coils are / \ available for use in Puron®, R-410A refrigerant and R-22 . systems. Both designs have a painted case and come with factory-installed ` thermostatic expansion valves (TXV). The coils are offered in O different width configurations for use in multiple installation A 0 applications. Additionally, they are offered in a transition *� configuration, a design which simplifies making field-supplied Ctil transition duct configurations.Easy maintenance is provided as the coil slides out of the cabinet after removing the access door and service panel. The coils are available in sizes 018 through 061 (1-1/2 to 5 tons). Transition coil models CNPVT and CNRVT are designed for use A06006 with one size smaller width furnaces without field modifications. CN(P,R)VP CN(P,R)V(P,T)and CNPVU are available in tin-plated copper coil models. These coils are built with special hairpins which are 41/11‘41/ , tin-plated to resist both general pitting corrosion and excessive indoor corrosion-formicary corrosion. (Formicary corrosion is an industry phenomenon.) O STANDARD FEATURES Water Management—These coil designs do an excellent job of ci 0 water management.The coils are designed to avoid water blow-off into the ducts by directing condensate away from the fins and into the drain pan. Durable Condensate Pan — Each coil is equipped with a corrosion-resistant condensate drain pan. The condensate drain i Clib pan is designed with a slope to help ensure proper drainage, improved moisture removal,and home,,comfort. A06007 Compact Design—Unique design offers as much as 2 to 4 in.(51 CN(P,R)VT(Transition) to 102 mm)less in height to aid in tight installations. Brass Inserts—Every condensate pan features two 3/4 in.female • threaded brass insert connections.The unique brass inserts provide - NNNI••.... for a leak-free condensate line connection to prevent water 4_ damage. Refrigerant Connections—The coils are provided with proven sweat-connections for leak-free operation maintaining system I';7I�'"; reliability. 0 1,,� Burst Pressures—These coils meet or exceed burst pressure of .1• 2100 psi which is at least three to five times the pressure they will see in actual application. r Thermostatic Expansion Valves (TXV) — All Carrier® coils ', have refrigerant-specific factory-installed TXVs. '►� Teflon Ring—The ring,installed inside the liquid line connection at the TXV, is the best option for preventing refrigerant leaks and A06004 future service calls. Teflon works with both Puron, R-410A, the CN(P,R)VU environmentally friendly refrigerant and R-22 refrigerants. Protective Tube Sheets—Protect the durable copper tubing from being damaged during the manufacturing and installation process. 24ABB3 Comfort TM 13 Air Conditioner with Puron® Refrigerant Carrie 1 -1/2 to 5 Nominal Tons turn to the experts Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency • 13.0 - 13.2 SEER/10.8- 11.0 EER (based on tested combinations) • Microtube Technology"" refrigeration system • Indoor air quality accessories available Sound • Sound level as low as 75 dBA • Sound level as low as 74 dBA with accessory sound blanket Comfort • System supports Edge® Thermidistat- or standard thermostat controls -Reliability • Puron® refrigerant - environmentally sound, won't deplete the ozone layer and low lifetime servce cost. ® Comfort • Scroll compressor Puron- SERIES • Internal pressure relief valve the cmv°nmxnally sound rw,p..m • Internal thermal overload • Filter drier Carrier's Air Conditioners with Puron® refrigerant provide a collection of features unmatched by any other family of • Balanced refrigeration system for maximum reliability equipment. The 24ABB has been designed utilizing Carrier's Durability Puron refrigerant. The environmentally sound refrigerant allows WeatherArmor" protection package: you to make a responsible decision in the protection of the earth's ozone layer. • Solid,durable sheet metal construction This product has been designed and manufactured to meet • Dense wire coil guard available Energy Star® criteria for energy efficiency when matched with (3-phase units come standard with dense wire coil appropriate coil components. Refer to the combination ratings in guard) the Product Data for system combinations that meet Energy Star® • Baked-on,complete outer coverage, powder paint guidelines. Applications NOTE: Ratings contained in this document are subject to • Long-line - up to 250 feet(76.20 m)total equivalent change at any time. Always refer to the AHRI directory length, up to 200 feet (60.96 m) condenser above (www.ahridirectory.org) for the most up-to-date ratings evaporator,or up to 80 ft. (24.38 m)evaporator above information. condenser(See Longline Guide for more information.) • Low ambient (down to -20°F/-28.9°C)) with accessory kit