Loading...
Permit CITY OF TIGARD REROOF PERMIT :a1 COMMUNITY DEVELOPMENT Permit#: RER2015-00002 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/07/2015 Parcel: 25101 BCO2201 Jurisdiction: Tigard Site address: 8300 SW HUNZIKER RD Project: Western Partitions Warehouse Subdivision: TIGARDIA TERRACE Lot: 3 Project Description: Install poly separation sheet over existing roof,GAF 60 MIL TPO,flashings. Contractor: INTERSTATE ROOFING INC Owner: HUNZIKER ONE LLC 15065 SW 74TH AVE 956 WEST POINT RD PORTLAND, OR 97224 LAKE OSWEGO, OR 97034 PHONE: 503-684-5611 PHONE: FAX: 503-639-3056 FEES Description Date Amount Permit Fee 01/07/2015 $797.22 Specifics: 12%State Surcharge-Building 01/07/2015 $95.67 Type of Use: COM Class of Work: ALT Type of Const: Occupancy Load: Stories: Height: 0 ft Project Valuation: $58,654.00 General Information Building Area 0 Re-Roof Area: 0 Roof Class: Tear Off: Overlay: Existing Roof Layers: Parapets: Total $892.89 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through 0 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: � Permittee Signature: �_ y Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Commercial RECEIVEP FOR OFFICE USE ONLY lig City of Tigard DaceiBed y* Permit No.' v 4 13125 SW Hall Blvd.,Tigard,OR 97223 JAN 7 2015 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: 1'I C n R D Inspection Line: 503.639.4175 'CITY OF TIGARD Date Ready/13y: Juris: Etil See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information BUILD NG DIVISIC TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rowded to the nearest dollar)of all ❑Addition/alteration/replacement ,Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ❑Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder e<Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: t,3 ci C ..56u ,41.4., 2/1c-6-a' A'P- New dwelling area: square feet City/State/ZIP: 7-1 c. iv pi a;?. 97.z.:e3 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:0J65-2 th"j /)Ak 7 77 c of S Covered porch area: square feet Cross street/directions to job site: /;J,A]/z t/p LL5 c Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rotnded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. IA-LS.7AL i— /24L y S 47/9.- A) j/a/u .Billet'„ a U eR C,e/6.72,4 dr Valuation: $ 5.8/ 6 5y Kt-c 67 A/= a ti, L 7-/-°/ FL Aselii;6- Existing building area square feet New building area: square feet KPROPERTY OWNER ❑ TENANT Number of stories: Name: r/tJ - Ei22/i .41k/ !!64—. 7 7 i/iv Type F � /nJ�' ��� / �— T e of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:(50.3) 5/9__/S/8 Fax:( ) New: APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name: //,./7 ,, 4 Tk 1e t;%i t.' (Please refer to fee schedule) Structural plan review fee(or deposit): Contact name: 1,o t—. 42)/- Ai e&. A S FLS plan review fee(if applicable): Address: /6"—c.; Cy- ,S w 7 4/7--7/ /9 6_ Total fees due upon application: City/State/ZIP: /0,e,,,, T L /V D ' 6 2, 9 7:.Z-2 if Phone:(S v l 4:,fs y_ ,54 // Fax:: i3 e.39.--, 30Z,-.6 Amount received: E-mail: PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name: /A) T t�„$'7 4 '5 , G�!`� /tJ Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: /s`c■ 6:5 5 t 7V274 1.2 e.-, Solar Installation Specialty Code checklist. City/State/ZIP: /404,3,R r R. '7�1 �/ Permit fee(includes plan review r9ti D 9 and administrative fees): $180.00 Phone:(.5c3) G: 'y_ 5 G if Fax:(503) 3?-- 3G S‘ State surcharge(12%of permit fee): $21.60 CCB lie.: 5 Y f, y Total fee due upon application: $201.60 Authorized signature• atAii 4 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: 4 6 L/L/S 6R n; L L 4 5 Date: * Fee methodology set by Tri-County Building Industry Service Board .; 2 17 I:\Buildine\Permits\BUP-COM PennitAon.doc 02/24/2011 440-4613T(11/02/COM/WEBI q Building Division Accessibility: Barrier Removal Improvement Plan TIGARD REQUIREMENT: OREGON REVISED STATUTE (ORS) 447.241. (1) Every project for renovation,alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities unless such alterations are disproportionate to the overall alterations in terms of cost and scope. (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five per-cent(25%). VALUATION: Total of all renovation,alteration or modification being done, excluding painting and wallpapering: [1] $ MULTIPLIER(25%barrier removal requirement): x .25 TOTAL BUDGET FOR BARRIER REMOVAL: [2] $ ELEMENTS: In choosing which accessible elements to provide under this section,priority shall be given to those elements that will provide the greatest access. Elements shall be provided in the following order: (a) Parking $ (b) An accessible entrance: $ (c) An accessible route to the altered area: $ (d) At least one accessible restroom for each sex or a single unisex restroom: $ (e) Accessible telephones: $ (f) Accessible drinking fountains:and, $ (g) When possible,additional accessible elements such as storage and alarms: $ TOTAL(shall equal line [2] of Valuation Computation): $ I:\Building\Permits\BUP-COM PermitApp.doc 03/03/2011 OFFICE COPYKliCEIVWWW r 2011 ROOFING MATERIALS AND SYSTEMS DIRECTORY JAN 7 2015 ITY ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATER1'ee''�t k. TIGARD SiT1G DIVIS'r31s Roofing Systems (TGFU)-Continued Roofing Systems (TGFU)-Continued ' 31. Deleted Surfacing(optional): Broadcast application of No.11 ceramic coated 32. Deleted granules applied at a rate of 30 to 50-lbs/100-ft.2 33. Deleted 50. Deck:NC Incline:1444 34. Deleted . Insulation: "Polyfoam 273,"any thickness. 35. Deleted Base Coat: "GacoSil S-2000 Series,"applied at 44-ga1/100-ft2 36. Deleted Top Coat: "GacoSil S-2000 Series,"applied at 3-gal/100-ft2 37. Deleted Surfacing(optional): Broadcast application of No. 11 ceramic coated 38. Deck:NC Incline:2 granules applied at a rate of 313-lbs/100-ft2. Primer(Optional): "Gaco Primer",(not UL classified). GAF MATERIALS CORP R1306 Base Coat "GacoSil S-1600"(GacoRoof)at 1 gal sq. 1361 ALPS RD,WAYNE NJ 07470 Top Coat: "GacoSil S-1600"(GacoRoof)at 1 gal sq. "Ruberoid® 20" or "Ruberoid® 20 HT" or "Ruberoid® Modified Base Surfacing(Optional): Roofing granules applied at 30 to 35 lbs sq. Sheet"may be utilized as an alternate to Type G2 base sheets in any of the 39. Deck:NC Incline:2 following Classifications. Foam: "Polyfoam 273",2 inches maximum 1-in. thick(minimum) gypsum board or %-in. thick (min)G-P Gypsum Corp."DensDeck®Roofboard,""DensDeck Prime®Roofboard"or"Dens- Base Coat: "GacoSil S-1000 Series"or"GacoSil S-1.600 Series"at 1.1 Deck DuraGuardTM Roofboard"may be used in any existing noncombustible gal sq. deck Classification. When this is done, the resulting roofing system is Top Coat: "GacoSil 5-1000 Series"or"GacoSil S-1600 Series"at 1.1 gal acceptable for use over combustible(15/32-in.thick minimum)roof decks. sq. However, the butt joints in the gypsum board and G-P Gypsum Corp. Surfacing(Optional): Roofing granules applied at 30 lbs.sq. "DensDeck® Roofboard," "DensDeck Prime®Roofboard" or "DensDeck 40. Deck:NC Incline:1/4 DuraGuardTM Roofboard" are to offset a minimum of 6-in. with the butt Foam: Polyfoam 273",2 inches thick. joints in the roof deck.If polystyrene is part of the roof system,it must be Base Coat: "U 62",1.25 al/s placed below the overlayment board. gal/sq. Multiple plies of"GAFGLAS®Ply 4"or"Tri-Ply®Ply 4"or'Tri-Ply®Ply i U Second Base Coat: " -62",0.75 gal/sq.(Optional walnut shells at 8 6" may be adhered to G-P Gypsum Corp. "DensDeck ® Roofboard," -10 lbs sq.) "DensDeck Prime®Roofboard"or"DensDeck DuraGuardTM Roofboard"in I Surfacing: "U-62",0.75 gal/sq. hot roofing asphalt. 41. Deck:NC Incline:1/4 "EnergyGuard Ultra"is an acceptable alternate to"EnergyGuard"in any Foam: "Polyfoam 273",2 inches thick. applicable Classification. Base Coat: "iJ6 8380",1.5 gal/sq. 'GAF Stratavent® EliminatorTM Venting Base Sheet (Nailable)" may be i Top Coat: "5-10 Series",1.5 gal/sq. mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. Surfacing(Optional): No.11 roofing granules applied at 50 lbs.per "GAFGLAS® Perlite Insulation"ma be utilized as a cover board over sq. "EverGuard"insulation in any of the following systems. 42. Deck:NC Incline:3/4 Unless otherwise indicated,the roof insulation is mechanically fastened, Foam: "Polyfoam 273",2 inches thick. adhered with hot mopping asphalt or urethane insulation adhesive.Poly- Base Coat: "U-6006",3.5 gal/sq.(Three applications at 1.16 gals/sq.) styrene referenced in any of the following Classfications include"Energy- ' Second Base Coat: "U-6006",0.85 gal/sq. Surfacing: "U-6006",0.85 gal/sq.(Optional No.11 roofing granules at Guard EPS Insulation".References to glass fiber insulation include "EnergyGuard Fiberglass 301bs./sq.) Insulation". 43. Deck:NC Incline:1-1/4 ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Foam: "Polyfoam 273",2 inches thick. Type G2 asphalt glass mat base sheet("GAFGLAS®#75 Base Sheet"or Base Coat: f 32 Series",inches gal/sq. "Tn'-Ply®#75 Base Sheet", or "GAFGLAS®#80 ULTIMA" ) is a suitable g q alternate for Type G1 asphalt glass fiber ply sheet("GAFGLAS®Ply 4"or Surfacing: "A 32 Series",1.5 gal/sq. 'Tri-Ply®Ply 4',or"GAFGLAS®Ply 6")in the Class A,B or C roof systems 44. Deck:NC Incline:1-1/4 indicated below. Foam: "Polyfoam 273",2 inches thick. The roof deck may first be covered with one ply Type G2 asphalt saturated Base Coat: Conklin Co.Inc."Conklin Benchmark",1.9 gal/sq. glass mat base sheet "GAF Stratavent® EliminatorTM Venting Base Sheet Surfacing: Conklin Co.Inc."Conklin Benchmark",1.9 gal/sq. (Perforated)"or"GAF Stratavent®EliminatorTM Venting Base Sheet (Nail- 45. Deck:NC Incline:2 able)."Perforated to be loose laid or mopped and nailable to be mechanically attached granule side down. Base Coat: "A-38 Series",0.75 gal/sq. 8r Second Base Coat: "A-38 Series",0.75 gal/sq. As an option Type G2 asphalt glass mat base sheet("GAFGLAS®#75 Base Wear Coat: "A-38 Series",0.75 gal/sq plus walnut shells at 0.75 lbs Sheet"or"Tri-Pl #75 Base Sheet"or"GAFGLAS®#80 may s"or"GAF Stratavent®EliminatorTM Venting Base Sheet(Nailable)"may be substituted per sq. for Type Cl asphalt glass fiber ply sheet("GAFGLAS®Ply 4"or"Tri-Ply® Surfacing: "A-38 Series",0.75 gal/sq plus walnut shells at 0.75 lbs Ply 4' or "GAFGLAS® Ply 6' ) as the nailed base ply in the following per sq. systems. 46 Deck:NC Incline:3/4 Bottom ply or base sheet may be solid mopped,spot mopped or mechani- Foam: Spray application of 2-in.thick"Polyfoam 273"(2.7 lb/ft.3) cally fastened. Surfacing: Spray application of 28 to 34-mils"U-8730"(aluminum) Unless otherwise indicated,all insulations may be hot mopped or mechani- 47 Deck:NC Incline:1/2 cally fastened. Insulation: Spray application of 2-in.thick"Polyfoam 273"(2.716/ft 3 GAFGLAS®Flashing"or"Ruberoid®"may be used for flashing in any of the Class A,B or C systems listed below. Surfacing: Spray application of 28 to 34 mils"U-8782"(ivory) When"perlite"is referenced,this includes"GAFTEMP PERMALITE®"or 4; 48. Deck:NC Incline:life an other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class Insulation: Spray application of 2-in.thick"Polyfoam 273". A,B or C systems listed. Base Coat: "A3100R Acrylic Top Coat"or"A3111R Acrylic Base Coat" Structural cement fiber building units are considered suitable to be t`; applied at 1.13 gal/100 ft 2 included as a deck in the following Class A, B or C systems listed over Intermediate Coat: "A3100R Acrylic Top Coat"or"A3111R Acrylic C-15/32 or NC. ....1.1,,,: Base Coat"applied at 1.13-gal/100-ft 2 The use of gypsum board under any of the following Class A, B or C Top Coat: A3100R Acrylic Top Coat"applied at 1.13-gal/100-ft.2 systems does not adversely effect the rating.The use of 1-in.minimum thick Surfacing(optional): Broadcast application of No.11 ceramic coated gypsum board is an acceptable alternate for minimum insulation over granules applied at a rate of 30 to 50-lbs/100-ft.2 G15/32 thick roof decks. Deck:NC Incline:3/4 The use of polystyrene insulation board between minimum 3/-in. thick perlite board and deck with rosin paper(perlite/rosin paper/polystyrene/ 1, : . Base Foam(Optional): "PolyFoam 193,"any thickness. pp "." Surface Foam: "Polyfoam 273,"1 inch minimum Classe) is a suitable syst alternate for polyisocyanurate board in the following "�''` y Class A,B or C systems. i . '' Base Coat: "Gacoflex A-3200R Series"applied at 1.5 gal/100-ft2 "EnergyGuard RA" or "Tapered EnergyGuard RA" or "EnergyGuard Top Coat: "Gacoflex A-3200R Series"applied at 1.5 gal/100-ft2 Composite RA"may be substituted for any Atlas polyisocyanurate insulation • 2011 ROOFING MATERIALS AND SYSTEMS DIRECTORY ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATERIALS(TEVT) 281 Roofing Systems (TGFU)-Continued Roofing Systems (TGFU)-Continued Insulation (Optional): Perlite, wood fiberboard, polyisocyanurate, Insulation: Polystyrene,polyisocyanurate,polyurethane,kraft-faced perlite/polyisocyanurate, fiberboard/polyisocyanurate, hot mopped glass fiber, perlite, wood fiber, gypsum board, any thickness, laid or mechanically fastened. loosely. Base Sheet: One or more plies "GAFGLAS® #75 Base Sheet" or Slip Sheet(Optional): Glass fiber reinforced kraft paper. "Tri-Ply®#75 Base Sheet"or"GAFGLAS®#80 Premium Base Sheet"or Membrane: "EverGuard PVC",50-80 mil laid loosely. "GAF Stratavent Eliminator Venting Base Sheet (Mailable)" or Surfacing: River bottom stone(r/to 2-1-in.diameter)1000-1b/100-ft2 "Ruberoid®Modifed Base Sheet"or"Ruberoid®20"or"Ruberoid®20 or crushed stone(1 to 34-in.)at 900-lbs/100-ft2 minimum,or concrete HT"or"Ruberoid®Dual Smooth"mechanically fastened. blocks (10-1b/ft2 ) spread not more than 1/8-in. apart, or "STYRO- Ply Sheet: One or more plies"GAFGLAS®Ply 4"or"Tri-Ply®Ply 4" FOAM" panels surfaced with 3/8-in. (maximum) concrete mortar or "GAFGLAS® Ply 6" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® (panels to be abutted together). Ultra-Flexible Ply 6"hot mopped. 2. Deck:NC Incline:3 Cap Sheet: "Ruberoid®Torch Smooth"or"Ruberoid®Torch Gran- Insulation: a)Polystyrene,2-in.maximum,b)polyisocyanurate,any ule"or"Ruberoid®Torch Granule Plus"or"Ruberoid®Mop Smooth" thickness,laid loosely. or"Ruberoid®Mop Smooth 1.5"or"Ruberoid®Mop Smooth Plus"or Membrane: "Ever Guard SR"or"Ever Guard EGFB,"(TPA)40-100 mil, "Ruberoid® Mop Granule" or "GAFGLAS® Mineral Surface Cap laid loosely. • Sheet"or"Tri-Ply®Mineral Surfaced Cap Sheet"or"Ruberoid®Dual Surfacing: River bottom stone(3/4-11/2-in.diameter)at 1000-lb/100-ft2 Smooth." or concrete roof pavers. 15. Deck:NC Incline:1/2 Class A-Fully Adhered Insulation (Optional): One or more layers perlite or glass fiber it 1. Deck:NC Incline:1-1/2 polyisocyanurate or perlite/polyisocyanurate composite or perlite/ Gypsum Board: 1/2-in.,mechanically fastened. urethane composite or wood fiber/polyisocyanurate composite, any Membrane: "EverGuard EGFB"(TPA)40-100 mil. thickness. 2. Deck:NC Incline:2 Base Sheet: One or more plies Type G1 or Type G2,mechanically Gypsum Board(Optional): 1-in.,mechanically fastened. fastened or hot mopped. Insulation: Johns Manville"ENRGY 1G"or Firestone Building Prod- Ply Sheet (Optional): One or more plies Type Gl, mechanically ucts"ISO 95+GL"or Apache Building Products"Pyrox White Line", fastened or hot mopped. any thickness. ' Membrane: One or more plies "Ruberoid® Mop Smooth" or Membrane: "EverGuard EGFB"(TPA)40-100 mil. "Ruberoid®Mop Smooth 1.5" or "Ruberoid®Mop Smooth Plus" or 3. Deck:NC Incline:1-1/2 "Ruberoid®Dual Smooth." Gypsum Board(Optional): 1-in.,mechanically fastened. Surfacing: "WeatherCote."'"applied at 2-gal/100 ft2. Insulation: Rmax Inc.'"Thermaroof Plus-3",any thickness. 1 16. Deck:NC Incline:1/2 Membrane: "EverGuard EGFB"(TPA)40-100 mil. Insulation (Optional): One or more layers perlite, glass fiber, 4. Deck:C-15/32 Incline:3-1/2 1 polyisocyanurate, perlite/polyisocyanurate composite, perlite/ Insulation(Optional): Polyisocyanurate,extruded or expanded poly- urethane composite, wood fiber/polyisocyanurate composite, phe- styrene,any thickness. nolic,any thickness. Barrier Board: Minimum'-in.thick gypsum wallboard or minimum r ) Base Sheet: One or more plies Type G1 or Type G2,mechanically 1/4-in. G-P Gypsum Corp. "DensDeck ® Roofboard," "DensDeck fastened or hot mopped. Prime®Roofboard"or"DensDeck DuraGuardlM Roofboard". f Ply Sheet (Optional): One or more plies Type Gl, mechanically Membrane: "EverGuard EGFB"(TPA)40-100 mil. fastened or hot mopped. 5. Deck:NC Incline:2-1/2 Membrane: One or more plies"Ruberoid®Torch Smooth"Heat fused Insulation: Celotex"Thermax Hy-Tec",any thickness. Surfacing: "WeatherCoteT'"Low VOC"or"WeatherCoterm"applied Membrane: "EverGuard EGFB"(TPA)40-100 mil. at 2-gal/100 ft2. 6. Deck:NC Incline:2 1 Insulation: Celotex"Hy-Therm AP",any thickness. 7- Deck:C 15/32 Incline:1/2 Membrane: "EverGuard EGFB"(TPA)40-100 mil. t i Slip Sheet(Optional): 1 ply"StormSafe"mechanically fastened. 7. Deck:NC Incline:2 Base Sheet: One or more plies"Liberty SBS Self-Adhering Base/Ply Insulation: Johns Manville"ENRGY 1G"or Atlas Roofing"ACFoam Sheet"or"Ruberoid®SA Base/Ply Sheet"self adhered. II"or Rmax Inc."Thermaroof Plus-3"or"Multi-Max-3"any thickness. Cap Sheet: One or more plies"Liberty SBS Self-Adhering Cap Sheet" Membrane: "Ever Guard EGFB"(TPA)40-100 mil. or "Ruberoid® SA Cap Sheet" or "Ruberoid® SA Cap FR Sheet" 8. Deck:NC(Concrete) Incline:1 it self-adhered. Insulating Concrete(Optional): Deck covered with one of the follow- 18. Deck:NC Incline:1/2 ing insulating concretes(poured in place):Cellular,vermiculite,perlite, it Primer. "Fire Out"applied at 1-gal/100-W. gypsum or structural. Insulation: Polyisocyanurate,perlite,glass fiber or wood fiber,2-in. Membrane: "EverGuard EGFB"(TPA)40-100 mil. maximum,hot mopped or mechanically fastened. 9. Deck:Structural'Cement Fiber Unit Incline:2 1 Slip Sheet(Optional): 1 ply"StormSafe"mechanically fastened Insulation(Optional): One or more of the following or combinations, 1 Base Sheet(Optional): One ply"Liberty MA Base Sheet"mechani- any thickness:Johns Manville"ENRGY 1G"or Rmax Inc."Thermaroof ally fastened. Plus-3"or"Multi-Max-3"or Atlas Roofing"ACFoam I"or"ACFoam it Ply Sheet: One ply"Liberty SBS Self-Adhering Base/Ply Sheet"or II„ x "Ruberoid®SA Base/Ply Sheet"self adhered. Membrane: "EverGuard EGFB"(TPA)40-100 mil. r Cap Sheet One ply "Liberty FR SBS Self-Adhering Cap Sheet"or 10. Deck:NC Incline:2 "Ruberoid® SA Cap Sheet" or "Ruberoid® SA Cap FR Sheet" self Vapor Retarders (Optional,not UL Classified): (1) 6 mil polyethyl- adhered. ene,(2)Kraft or(3)Kraft laminate. SINGLE PLY MEMBRANE ROOFING SYSTEMS(TPA,PVC and Insulation: One or more of the following or combinations,mechani- unless otherwise indicated,"EverGuard SR"membranes used in systems cally fastened, any thickness: Rmax "Multi Max" or Atlas Roofing "; hanically fastened with large head metal or plastic fasteners with an "ACFoam II"or Johns Manville"ENRGY 1G". . utter, spacing of 18-in. and maximum 2-in. from membrane's edge. Membrane: "EverGuard EGFB"(TPA)40-100 mil. . -rent sheets are lapped 4-in., covering fasteners. Laps are then heat- 11. Deck NC Incline:2-1/2 Vapor Barrier(Optional): Polyethylene or polypropylene,any thick- It' ..°` .e,';',."-:...'` "EverGuard EGFB" (TPA) membranes are fully adhered with hot ness. ! t. `'C Ig asphalt. Insulation: Celotex Corp."Hy-Therm AP"2 in.thick maximum. Class A-Ballasted Membrane: "'EverGuard EGFB"(TPA)40-100 mil. ._., ' „ ��� C-15/32 Incline:2 12. Deck:C-15/32 Incline:2 - - --t •_ .nn.,rnn Tur .n ......,An.. n..w....•...- 282 ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATERIALS(TEVT) Roofing Systems (TGFU)—Continued; Roofing Systems (TGFU)—Continued Barrier Board: Gypsum wallboard, 1-in, minimum, butt joints in Base Sheet: One or more plies Type G1 or Type G2 or"GAF Stratavent wallboard staggered a minimum of 6-in.from plywood decks butt joints. Eliminator Venting Base Sheet(Nailable)",mechanically fastened. Insulation: Johns Manville"ENRGY 1G"or Atlas Roofing"ACFoam II" Ply Sheet(Optional): One or more plies Type G1"GAFGLAS®Ply 6" or Rmax Inc."Thermaroof Plus-3"or"Multi-Max-3",any thickness. hot mopped or mechanically fastened. Membrane: "EverGuard EGFB"(TPA)40-100 mil. Membrane: Two or more plies"Ruberoid®20"or"Ruberoid®20 HT" 13. Deck:NC Incline: 1 or "Ruberoid®Dual Smooth" or three or more plies Type Cl "GAF. Insulation (Optional) : Polyisocyanurate,any thickness,mechanically fastened or hot mopped. GLAS"Ply 6",hot mopped. Ply Sheet (Optional) One or more plies Type Gl or T e G2, hot Membrane: "EverGuard TPO FB" or "600 Ultra" or "800 Ultra" or mopped YP "EverGuard EGFB" 40-100 mil (TPA), hot mopped or mechanically fastened. Membrane: EverGuard"EGFB"(TPA)40-100 mil,hot mopped. 30. Deck:C-15/32 4. Deck:NC Incline:3/4 Incline:1 Insulation: Any UL Classified polyisocyanurate,minimum 3 in.thick. Insulation: Polyisocyanurate,any thickness,mechanically fastened. Base Sheet: One or more plies Type Cl or Type G2 or"GAF Stratavent Cover Board: Perlite,any thickness,hot mopped. Eliminator Venting Base Sheet(Nailable)",mechanically fastened. Ply Sheet: One or more plies"Ruberoid®Mop Smooth"or"Ruberoid® Ply Sheet(Optional): One or more plies Type Cl"GAFGLAS®Ply 6", Mop Smooth 1.5"or"Ruberoid®Mop Smooth Plus"or"Ruberoid®Dual hot mopped or mechanically fastened. i Smooth"hot mopped in place. Membrane: Two or more plies"Ruberoid®20"or"Ruberoid®20 HT" Membrane: EverGuard"EGFB"(TPA)40-100 mil.hot mopped. or "Ruberoid®" Dual Smooth" or three or more plies Type Gl "GAF- 5. Deck:NC Incline:1 GLAS®Ply y 6",hot mopped. Insulation: One of the following any thickness: Membrane: "EverGuard TPO FB" or "600 Ultra" or "800 Ultra" or t 1. "EnergyGuard" "EverGuard EGFB" 40-100 mil (TPA), hot mopped or mechanically $ 2. "EnergyGuard RA" fastened. 3. Firestone Building Products"ISO 95+GL" 31. Deck:NC Incline:3/4 4. Atlas Roofing"ACFoam II" Insulation (Optional): Wood fiber, glass fiber, perlite, 1/2-in. thick Membrane: "EverGuard PVC SR"40-80 mil adhered with"EverGuard minimum. #2331 Bonding Adhesive"applied at 1-gal/60-ftz. Membrane: One ply"EverGuard TPO FB"or"450 Ultra"or"600 Ultra" Deck:C-15/32 Incline:Unlimited or"800 Ultra"hot mopped or mechanically fastened. Insulation: Any UL Classified insulation,any thickness. 32. Deck:NC Incline:1/2 Barrier Board: minimum _in.thick G P Gypsum nsulation(Optional): Minimum 11/2-in.thick wood fiber over any UL Yp Corp.rp."DensDeck® Classified polyisocyanurate,any thickness. i Roofboard," "DensDeck Prime® Roofboard" or "DensDeck Dura- GuardTM Roofboard"(butt joints in barrier board staggered a minimum Membrane: "EverGuard Freedom TPO"45,Incline:2 or 80-mil self adhered. of 6-in.from butt joints of the plywood deck) gg 33. Deck:NC Incline:2 Membrane: "EverGuard PVC SR",40-80 mil adhered with"EverGuard 34. Deck C 15/32"EverGuard Freedom TPO"45,Incline:2 or 80 mil self adhered. 1 #2331 Bonding Adhesive"applied at 1-gal/60-ft2. ied,a 2 i Deleted Insulation(Optional): Any UL Classified,any thickness. r Deck:NC Barrier Board: Minimum V4-in.thick G-P Gypsum Corp."DensDeck® Incline:1/2 Roofboard," "DensDeck Prime® Roofboard" or "DensDeck Dura- Insulation: Atlas Roofing"ACFoam II"or"EnergyGuard RA"or wood GuardTM Roofboard" fiber or glass fiber or perlite,any thickness. Membrane: "EverGuard Freedom TPO"45,60 or 80-mil self adhered. Membrane: "EverGuard TPO" 45-80 mil, fully adhered with "TPO 35. Deck:NC Bonding Adhesive",applied at 60-ft2/gal. Incline:1/4 "Energy- Deleted Insulation(Optional): Atlas Roofing Corp."ACFoam II"or"Energy- Deleted Guard RA"or Johns Manville International Inc."ENRGY 3"or Energy- Deleted Guard RN"or Firestone Building Products ISO 95+ GL"or"Energy- Deck:NC Guard"or wood fiber or glass fiber or perlite,any thickness. Incline:1/2 g P Y Insulation: Atlas Roofing lip Sheet(Optional): 1 ply"StormSafe"mechanically fastened g Corp.rp."ACFoam II"or"EnergyGuard RA"or Membrane: "EverGuard Freedom TPO"45,60 or 80-mil self adhered. wood fiber or glass fiber or perlite,any thickness. 36. Deck:C-15/32 Membrane: "EverGuard TPO" 45-80 mil, fully adhered with "Ever- Incline:2-1/2 Guard H2O Bonding Adhesive" or "EverGuard® WB 181 Bonding Deck ime® GP Roofboard"Gypsum Corp."DensDeck ardrM Roofboard"Roofboard","Dens- r Adhesive"applied at a rate of 120-ft. /gal. Deck Prime®Roofboazd"or"DensDeck DuraGuardTM Roofboazd",with # Deck:NC Incline:1/4 all butt joints in barrier board staggered a minimum of 6-in.from butt Insulation: Firestone Building Products "ISO 95+ GL" or "Energy- Membrane:in plywood"EverGuard deck. 44 Guard"or wood fiber or glass fiber or perlite,any thickness. gY Membrane: BverGuazd Freedom TPO"One:1/2 or 80 mil self adhered. 4 Membrane: "EverGuard TPO" 37. Deck:NC Incline:1/2 s 45-80 mil, fully adhered with "Ever- Insulation (Optional): Atlas Roofing"ACFoam II"or"EnergyGuard r Guard H2O Bonding Adhesive" or "EverGuard® WB 181 Bonding RA",any thickness. Adhesive"applied at 120 ft. /gal. Membrane: "EverGuard Freedom TPO"45,60 or 80 mil self adhered. Deleted 38 Deck:C-15/32 )eck:NC Incline:2-1/2 Incline:1 Membrane: One layer"EverGuard TPO FB 450 Ultra"or"EverGuard Base Sheet"Fire Out"applied at 1-gal/100-ft2 TPO FB 600 Ultra"or"EverGuard TPO FB 800 Ultra"fully adhered with Base Sheet(Optional): One ply Type G2,"StormSafe" r Atlas mechanically fastened. "EverGuard H2 0 Bonding Adhesive"or"EverGuard®WB 181 Bonding Slip Sheer"FR-50"or One ply ersaS"VersaShield or or Roofing Corp. Adhesive"applied at 120-ft.2/gal. g FR-10"or"FR-50"or Elk Corp. "VersaShield 15"or"VersaShield 2S" eck:NC mechanically fastened. Incline:2-1/2 Membrane: "EverGuard Freedom TPO"45,160 or 80-mil self adhered. Membrane: One layer"EverGuard TPO FB 450 Ultra","EverGuard TPO 39. Deck:NC 'B 600 Ultra"or"EverGuard TPO FB 800 Ultra"adhered with ITW-TALC Incline:95+ 'TACO 636"applied at 120-fe/gal. Insulation: Firestone Building Products ISO 95+GL"or Atlas Roofing )eleted Corp. "ACFoam II" or " EnergyGuard RA" or "EnergyGuard", any eck:NC Incline:1 thickness,any combination. Memane: One layer "EverGuard TPO FB 450 Ultra", "EverGuard Membrane: GAF "EverGuard TPO" 45 or 60 mil, adhered with i PO FB 600 Ultra"or"EverGuard TPO FB 800 Ultra",hot mopped or 40. Deck NC "EverGuard TPO#1121 Bonding Adhesive"applied at 60 ft2/gal. rechanically fastened. Incline:1 :ck:NC Incline:3/4 Insulation: "EnergyGuard"or"EnergyGuard Ultra"or"EnergyGuard 1 �sulation (Optional): Any UL Classified polyisocyanurate, RA"or Firestone Building Products Co."ISO 95+GL"or Atlas Roofing ber,glass fiber,or perlite any thickness. P yrsocyanurate, wood Corp. "ACFoam II"or Johns Manville International Inc."ENRGY 3"or "EnergyGuard RN"or wood fiber or glass fiber or perlite,any thickness. ' LOOK FOR THE UL MARK ON PRODUCT , LU11 HUUrINta NIA tHIAL,ANU,T,I tM, UIHtt:I UHT r ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATERIALS(TEVT) 283 Roofing Systems (TGFU)—Continued Roofing Systems (TGFU)—Continued Membrane: "EverGuard PVC"56 to 8J mil,adhered with"EverGuard Membrane: EverGuard TPO"45-60 mil, fully adhered with "Ever- #2331 Bonding Adhesive"applied at 60-ft2/gal. Guard TPO#1121 Bonding Adhesive"applied at 60-ft2 /gal.; "Ever- 41. Deck:NC Incline:1 Guard Freedom TPO"45,60 or 80-mil self adhered or"EverGuard TPO Insulation: "EnergyGuard"or"EnergyGuard Ultra"or"Pa argyGuard FB 450 Ultra"or"EverGuard TPO FB 600 Ultra"or"EverGuard TPO FB RA"or Firestone Building Products Co."ISO 95+GL"or Atlas Roofing 800 Ultra", adhered with "EverGuard H2O Bonding Adhesive" or Corp."ACFoam II"or Johns Manville International Inc."ENRGY 3"'cr , "EverGuard®WB 181 Bonding Adhesive"or ITW TACC"636"applied "EnergyGuard RN" or wood fiber or glass fiber or perlite, any it 129-ft.2/gal.;"EverGuard PVC"50-80 mil,adhered with"EverGuard thickness. H2 PJ Bonding Adhesive" applied at 0.83-gal/100-ft2 or "EverGuard Membrane: "EverGuard PVC"50 to 80 mil,adhered with"EverGuard #2331 Bordiang Adhesive"applied at 2-gal/100-ft2 H2 0 Bonding Adhesive" applied at 0.83-gal/100-ft2 or EverGuard® Surfacing: United Solar L:onics Field-Assembled Photovoltaic WB 181 Bonding Adhesive applied at rate of 120-ft-2/gal. (Solar) Module Systems, 'TVL-29,-31, -58,-60,-62,-64, -68,-87, -93, 42. Deck:C-15/32 Incline:3-1/2 -116,-120,-124,-128,-136,"self-adhered. Barrier Board: Minimum.V4-in.thick G-P Gypsum Corp."DensDeck 50. Deck:NC Incline:3/4 ®Roofboard," "DensDeck Prime® Roofboard" or "DensDeck Dura- Barrier Board(Optional): minimum'/-in.thick C-P Gypsum Corp. GuardTM Roofboard"with all butt joints staggered a minimum of 6-in. "DensDeck® Roofboard,""DensDeck Prime®Roofboard"or "Dens- from the plywood butt joints; staggered joints not required for non- Deck DuraGuardTM Roofboard" or gypsum wallboard mechanically combustible roof decks,mechanically fastened. fastened Membrane: "EverGuard PVC"50 to 80 mil,adhered with"EverGuard Slip Sheet (Optional): Elk Corp. "VersaShield", mechanically H2 0 Bonding Adhesive"applied at 0.83-gal/100-ft2 or"EverGuard® attached. WB 181 Bonding Adhesive"applied at a rateof 120-ft2 /gal. Base Sheet(Optional): Type 15 or Type 30 or Type G1 or Type G2, 43. Deck:C-15/32 Incline:1/2 mechanically attached or hot mopped. Barrier Board (Required For Combustible Deck): minimum 1/2-in. Membrane: EverGuard"EGFB"40 to 100 mil,hot mopped. thick gypsum board mechanically fastened with insulation fasteners Surfacing: United Solar Ovonics Field-Assembled Photovoltaic (barrier board butt joints staggered a minimum of 6-in.from butt joints (Solar) Module Systems, 'TVL-29,-31,-58, -60, -62, -64, -68,-87, -93, in plywood roof deck). -116,-120,-124,-128,-136,"self-adhered. Insulation: "EnergyGuard RA"or Atlas Roofing Corp."ACFoam II" 51. Deck:NC Incline:11/2 or 3/4-in.minimum wood fiberboard over EPS. Primer (optional): One application "SurfaceSeal SB" applied at Membrane: "EverGuard PVC" 50 to 80 mil, fully adhered with 1-gal./100-ft2. "EverGuard#2331 Bonding Adhesive"applied at 2-gal/100-ft2 Slip Sheet (optional): 1 ply"StormSafe"mechanically fastened 44. Deck:C-15/32 Incline:2 Membrane: "EverGuard Freedom TPO"45,60 or 80-mil self adhered. Barrier Board: minimum 1/2-in. thick gypsum board, mechanically 52. Deck:C-15/32 Incline:1-1/2 fastened with insulation fasteners.(barrier board butt joints staggered Slip Sheet: Two layers"VersaShield Underlayment"or"VersaShield a minimum of 6-in.from butt joints of plywood roof) FB-2S". Insulation: 3/4-in.minimum wood fiberboard over EPS. Membrane: "EverGuard PVC"50 to 80 mil,adhered with"EverGuard Membrane: "EverGuard PVC" 50 to 80 mil, fully adhered to the H2O Bonding Adhesive" applied at a rate of 0.83-gal/100-ft2 or insulation with "EverGuard #2331 Bonding Adhesive" applied at "EverGuard®WB 181 Bonding Adhesive"applied at a rate of 120-ft2 2-gal/100-ft2 /gal. or "EverGuard #2331 Bonding Adhesive" applied at a rate of 15. Deck:NC Incline:1/2 2-gal/100-ft2 Insulation: "EnergyGuard RA"or Atlas Roofing Corp."ACFoam H" 53. Deck:C-15/32 Incline:1 or/-in.minimum wood fiberboard over EPS. Slip Sheet: Three layers"VersaShield FB-1S"or two layers of either Membrane: "EverGuard PVC", 50 to 80 mil, fully adhered with "VersaShield FB-2S"or"VersaShield Underlayment". "EverGuard#2331 Bonding Adhesive"applied at 2-gal/100-ft2 Insulation: "EnergyGuard," "EnergyGuard RA," "Johns Manville 16. Deck:NC Incline:1 "ENRGY 3"or"EnergyGuard RN"or"EnergyGuard RD"or"Energy- Insulation (Optional): Polystyrene or polyisocyanurate, any thick- Guard Ultra"polyisocyanurate,any thickness ness. Membrane: "EverGuard PVC"50 to 80 mil,adhered with"EverGuard Barrier Board: minimum 15/32-in. thick plywood or 7/16-in. thick #2331 Bonding Adhesive"applied at 60-ft2/gal.or"EverGuard H2 0 oriented strand board. Bonding Adhesive"applied at 0.83-gal/100-ft2 or "EverGuard® WB Membrane: "EverGuard PVC" 50 to 80 mil, fully adhered with 181 Bonding Adhesive"applied at a rate of 120-ft2/gal. "EverGuard#2331 Bonding Adhesive"applied at 2-gal/100-ft2 54. Deck:C-15/32 Incline:2 :7. Deck:C-15/32 Incline:Unlimited Slip Sheet: Three layers"VersaShield FB-1S"or two layers of either Insulation(Optional): Any UL Classified(except EPS),any thickness, "VersaShield FB-2S"or"VersaShield Underlayment". uniform or tapered. Insulation: Any classified wood fiber board,any thickness. Barrier Board: minimum 1/4-in.thick C-P Gypsum Corp."DensDeck® Membrane: "EverGuard PVC"50 to 80 mil,adhered with"EverGuard Roofboard," "DensDeck Prime® Roofboard" or "DensDeck Dura- #2331 Bonding Adhesive"applied at 2 gal/100-ft2 GuardTM Roofboard"(butt joints of barrier board staggered a minimum 55. Deck:C-15/32 Incline:2 of 6-in.from the plywood deck butt joints;staggered joints not required Slip Sheet: Two layers"VersaShield Underlayment"or"VersaShield for noncombustible roof decks). FB-2S". Membrane: "EverGuard PVC" 50 to 80 mil, fully adhered with Membrane: "EverGuard PVC"50 to 80 mil,adhered with"EverGuard "EverGuard#2331 Bonding Adhesive"applied at 2-gal/100-ft2 H2 0 Bonding Adhesive"applied at 0.83-gal/100-ft2 or"EverGuard® 8. Deck:NC Incline:1/4 WB 181 Bonding Adhesive" applied at a rate of 120-ft2 /gal or Insulation: Firestone Building Products"ISO 95+"or Atlas Roofing "EverGuard#2331 Bonding Adhesive"applied at 2-gal/100-ft2 "ACFoam II"or"ACFoam III"any thickness,any combinations. 56. Deck:C-15/32 Incline:3/4 Membrane: "EverGuard TPO"45 or 60 mil,adhered with"EverGuard Slip Sheet: Two layers"VersaShield FB-1S". #1121 Bonding Adhesive"applied at 60-ft2/gal. Insulation (Optional): "EnergyGuard" or "EnergyGuard RA" or 9. Deck:NC Incline:1 Johns Manville International Inc."ENRGY 3"or"EnergyGuard RN"or Barrier Board(Optional): minimum 1-in.thick G-P Gypsum Corp. "EnergyGuard RD," or "EnergyGuard Ultra" polyisocyanurate, any "DensDeck ®Roofboard," "DensDeck Prime®Roofboard"or "Dens- thickness. Deck DuraGuardTM Roofboard" or gypsum wallboard mechanically Membrane: "EverGuard PVC"50 to 80 mil,adhered with"EverGuard fastened #2331 Bonding Adhesive"applied at 60-ft2/gal.or"EverGuard H2 0 Slip Sheet (Optional): Elk Corp. "VersaShield", mechanically Bonding Adhesive"applied at 0.83-gal/100-ft" attached. 57. Deck:NC Incline:2 Base Sheet (Optional): Type 15 or Type 30 or Type Cl or Type G2, Membrane: "EverGuard Steep Slope TPO" 45, 60 or 80-mil fully mechanically attached or hot mopped. adhered with"EverGuard H2 0 Bonding Adhesive"or"EverGuard® LOOK FOR THE UL MARK ON PRODUCT -- --.- •••••.-....-...v ruw v∎oil atria 1JIHC1."IUHT 284 ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATERIALS(TEVT) Roofing Systems (TGFU)-Continued Roofing Systems (TGFU)-Continued WB 181 Bonding Adhesive" applied at a rate of 120-ft2 /gal. or Membrane: "EverGuard®TPO Metallic"45,60 or 80-mil fully adhered "EverGuard 1121 Bonding Adhesive"applied at a rate of 60-ft2/gal. with"EverGuard®Steep Slope TPO Bonding Adhesive"bonding adhe. 58. Deck:NC Incline:Unlimited sive applied at a rate of 90-ft2/gal. Membrane: "EverGuard Steep Slope TPO," 45, 60 or 80-mil fully 70. Deck:C-15/32 Incline:41 adhered with "EverGuard Steep Slope TPO Bonding Adhesive" TPO Insulation (Optional): Fiberglass, polyisocyanurate, perlite or wood - bonding adhesive applied at a rate of 90-ft2 /gal. fiber, any thickness mechanically fastened or adhered with any UL 59. Deck:NC Incline:3 Classified insulation adhesive. Membrane: 45,60 or 80-mil thick"EverGuard TPO"fully adhered with Barrier Board: Minimum/-in.thick G-P Gypsum Corp. "DensDeck® "EverGuard Low VOC TPO Bonding Adhesive" applied at a rate of Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Dura- 1.1-gal./100 ft2. GuardTM Roofboard"mechanically fastened with all butt joints staggered 60. Deck:C-15/32 Incline:3 y 1 Insulation(Optional): Wood fiber,glass fiber or perlite,1/2-in.minimum a minimum of 6-m.from the plywood deck butt joints. thickness over any UL Classified insulation, any combination,minimum Membrane: "EverGuard®TPO Metallic"45,60 or 80-mil fully adhered thin any with"EverGuard®Steep Slope TPO Bonding Adhesive"bonding adhe Barrier Board: minimum�4-n. thick G-P Gypsum, ive applied at a rate of 90-ft2/gal. Corp.rp' DensDeck® 71. Deck:C-15/32 Incline:3 Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Dura- GuardTM Roofboard"with all butt joints staggered a minimum of 6-in. Insulation (Optional): Fiberglass, polyisocyanurate, perlite or wood from butt joints in the plywood deck. fiber, any thickness mechanically fastened or adhered with any UL Membrane: 45,60 or 80-mil thick"EverGuard TPO"fully adhered with Classified insulation adhesive. "EverGuard Low VOC TPO Bonding Adhesive" applied at a rate of Barrier Board: Minimum -in.thick United States Gypsum Co."SECU- 1.1-gal./100-ft2 ROCK®Roof Board"(Type FRX-G)"or"SECUROCK®Glass-Mat Roof 61. Deck:NC Incline:3 Board"(Type SGMRX) mechanically fastened with all butt joints stag- Membrane: 45, 60 or 80-mil thick "EverGuard Steep Slope TPO FB" gered a minimum of 6-in.from the plywood deck butt joints. fully adhered fully with EverGuard H2 0 Bonding Adhesive"applied at Membrane: "EverGuard®TPO Metallic"45,60 or 80-mil fully adhered a rate of 120-ft2 /gal. with"EverGuard®Steep Slope TPO Bonding Adhesive"bonding adhe- 62. Deck:C-15/32 Incline:3 sive applied at a rate of 90-ft'/gal. Insulation (Optional): Fiberglass, polyisocyanurate, perlite or wood 72. Deck:C-15/32 Incline:3 fiber, any thickness mechanically fastened or adhered with any UL Insulation (Optional): Fiberglass, polyisocyanurate, perlite or wood Classified insulation adhesive. fiber, any thickness mechanically fastened or adhered with any UL Barrier Board: Minimum 1A-in.thick G-P Gypsum Corp."DensDeck® Classified insulation adhesive. Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Dura- Barrier Board: Minimum Y4-in.thick G-P Gypsum Corp. "DensDeck® GuardTM Roofboard" with all joints staggered a min of 6-in. from the Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Dura- plywood joints. GuardTM Roofboard"or minimum 1-in.thick United States Gypsum Co. Membrane: 45, 60 or 80-mil thick "EverGuard Steep Slope TPO FB" "SECUROCK®Roof Board"(Type FRX-G)"or"SECUROCK®Glass-Mat fully adhered fully with EverGuard H2 0 Bonding Adhesive"applied at Roof Board"(Type SGMRX) mechanically fastened with all butt joints a rate of 120-ft2/gal. staggered a minimum of 6-in.from the plywood deck butt joints. 63. Deck:NC Incline:1/2 Membrane: "EverGuard®Steep Slope TPO"or"EverGuard®TPO FB Insulation: "EnergyGuard RA" or "EnergyGuard RD" or "Energy- Ultra Metallic"45, 60 or 80-mil thick fully adhered fully with "Ever- Guard RN"or Fiberglass or perlite or wood fiber,any thickness mechani- Guard®WB 181 Bonding Adhesive"applied at a rate of 120-ft2/gal. cally fastened or adhered with any UL Classified insulation adhesive. 73. Deck:NC Incline:/ Membrane: 45, 60 or 80-mil thick"EverGuard Steep Slope TPO FB" Insulation: "EnergyGuard®RA"or"EnergyGuard®RD"or"Energy- fully adhered fully with EverGuard H2 0 Bonding Adhesive"applied at Guard® RN" or Fiberglass or perlite or wood fiber, any thickness a rate of 120-ft2/gal. mechanically fastened or adhered with any UL Classified insulation 54. Deck:NC Incline:Unlimited adhesive. Membrane: 45, 60 or 80-mil thick"EverGuard Steep Slope Freedom Membrane: 45,60 or 80-mil thick"EverGuard®TPO FB Ultra Metallic" TPO"or"EverGuard®TPO FB Ultra Metallic"self-adhered fully adhered fully with "EverGuard® WB 181 Bonding Adhesive" )5. Deck:C-15/32 Incline:Unlimited applied at a rate of 120-ft2/gal. Insulation (Optional): Fiberglass, polyisocyanurate, perlite or wood 74. Deck:C-15/32 Incline:3 fiber, any thickness mechanically fastened or adhered with any UL Insulation (Optional): Fiberglass, polyisocyanurate, perlite or wood Classified insulation adhesive. fiber, any thickness mechanically fastened or adhered with any UL Bather Board: Minimum 14-in.thick G-P Gypsum Corp."DensDeck® Classified insulation adhesive. Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Dura- Barrier Board: Minimum Vi-in.thick United States Gypsum Co."SECU- GuardTM Roofboard"with all joints staggered a minimum of 6-in.from ROCK®Roof Board"(Type FRX-G)"or"SECUROCK®Glass-Mat Roof the plywood deck joints. Board"(Type SGMRX)mechanically fastened with all butt joints stag- Membrane: 45, 60 or 80-mil thick "EverGuard Steep Slope Freedom gered a minimum of 6-in.from the plywood deck butt joints. TPO"or"EverGuard®TPO FB Ultra Metallic"self-adhered Membrane: 45, 60 or 80-mil thick "EverGuard® Freedom TPO I-1W i. Deck:NC Incline:1 Metallic"self-adhered Membrane: 45,60 and 80-mil thick"EverGuard Steep Slope TPO FB" Class B-Fully Adhered fully adhered with hot roofing asphalt 1. Deck:C-15/32 Incline:1-1/2 '. Deck:C-15/32 Incline:1 Gypsum Board(Optional): 1-in.,mechanically fastened. Insulation (Optional): Fiberglass, polyisocyanurate, perlite or wood Slip Sheet: Atlas Roofing"FR-50". fiber, any thickness mechanically fastened or adhered with any UL Insulation: Apache Building Products"Pyrox White"2-in.minimum, Classified insulation adhesive. mechanically fastened. Barrier Board: Minimum 1-in,thick G-P Gypsum Corp."DensDeck® Membrane: "EverGuard EGFB" Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Dura- 2. Deck:NC (TPA)40 to mil. I Incline:1 GuardTM Roofboard" with all joints staggered a min of 6-in. from the Base Sheet: Type G3,hot mopped or nailed. plywood joints. Insulation: Firestone Building Products'ISO-95+GL"or Atlas Roofing Membrane: 45, 60 or 80-mil thick "EverGuard Steep Slope TPO FB" "ACFoam II",any thickness. fully adhered fully with hot roofing asphalt Membrane: "EverGuard EGFB" Deck:NC Incline:3 (TPA)40 to 11/mil. 3. Membrane: "EverGuard®Steep Slope TPO"or"EverGuard®TPO FB Base Set: Type G3,hot mopped orinailed. 1/2 Ultra Metallic"45,60 or 80-mil fully adhered with"EverGuard®WB 181 Insulation: Celotex"Top-R-II",any thickness. Bonding Adhesive"applied at a rate of 120-ft.2/gal. Membrane: "EverGuard EGFB" Deck:NC Incline:41/2 4. Deck:NC (TPA)40 to 100 miL Incline:34 LOOK FOR THE UL MARK ON PRODUCT 2011 ROOFING MATERIALS AND SYSTEMS DIRECTORY ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATERIALS(TEVT) 285 Roofing Systems (TGFU)-Continued Roofing Systems (TGFU)-Continued Insulation: Atlas Roofing"ACFoam II"or"GAFTEMP Isotherm RA" a PVC sealant(not UL Classified)applied to the exposed seam(approxi- or wood fiber or glass fiber or perlite,any thickness. mately 1/8-in.wide bead). Membrane: "EverGuard TPO Fd"'4.5 to 60 mil, fully adhered with Class A-Mechanically Fastened "EverGuard H2 0 Bonding Adhesive" applied at I82-ff.2 /gal. or 1. Deck:NC Incline:1/2 "EverGuard®WB 181 Bonding Adhesive"applied at a rate oi,(20-ft.2 Insulation: "GAFTEMP"or Atlas Roofing"ACFoam II"or Firestone /gal. "LSO 95+GL"or"Energy Guard",wood fiber or glass fiber or perlite, 5 Deck:C-15/32 Incline:4 ai)Thickness. Barrier Board: minimum'/-in.thick G-P Gypsum Corp.DensDeck® Meneoraa: "EverGuard TPO",45-80 mil. Roofboard,DensDeck Prime®Roofboard or DensDeck DuraGuardrm 2. Deck:NC Incline:2-1/2 Roofboard,with all joints staggered 6-in.from plywood joints. Membrane: "cerGuard TPO",45-60 mil. Membrane: "EverGuard TPO" 45 to 60 mil, fully adhered with 3. Deck:NC Incline:3/4 "EverGuard TPO#1121 Bonding Adhesive"applied at 60-ft2 /gal. Insulation: Atlas Roofing"ACFoam II" or "EnergyGuard RA" or 6 Deck:NC Incline:2 wood fiber or glass fiber or perlite,any thickness. Insulation(Optional): Minimum grin.thick wood fiber over any UL Membrane: EverGuard TPO",80 mil. 4. Deck:NC Incline:1/2 Classified polyisocyanurate,any thickness. Insulation(Optional): Atlas Roofing"ACFoam H"or"EnergyGuard Membrane: "EverGuard Freedom TPO"45,60 or 80-mil,self adhered. RA"or Firestone Building Products"ISO 95+GL"or"EnergyGuard"or 7. Deck:NC Incline:1/2 wood fiber or glass fiber or perlite,any thickness. Insulation: Firestone Building Products "ISO 95+ GL" or Atlas Membrane: "EverGuard TPO FB 450 Ultra","EverGuard TPO FB 600 Roofing Corp."ACFoam II"or"EnergyGuard RN'or"EnergyGuard", Ultra"or"EverGuard TPO FB 800 Ultra",mechanically fastened any thickness,any combinations. 5. Deck:NC Incline:3 Membrane: GAF "EverGuard TPO" 45 or 60 mil, adhered with Insulation: One of the following,any thickness: "EverGuard TPO#1121 Bonding Adhesive"applied at 60-ft2/gal. 1. "EnergyGuard" 8. Deck:NC Incline:3 2. "EnergyGuard RA" Insulation: "EnergyGuard RA"or Atlas Roofing Corp."ACFoam II" 3. Firestone Building Products"ISO 95+GL" any 4. Atlas Roofing"ACFoam II" ess. verGuard PVC," 50 to 80 mil, fully adhered with Membrane: "EverGuard PVC SR",40-80 mil. Membrane 6. Deck:NC Incline: "EverGuard#2331 Bonding Adhesive"applied at 2-gal/100-ft2 9. Deck:NC Incline:1/2 Insulation: Any UL Classified insulation,any an y thickness. an Unlimited Barrier Board: minimum r4-in.thick G-P Gypsum Corp."DensDeck® Insulation: Firestone Building Products"ISO 95+"or Atlas Roofing Roofboard," "DensDeck Prime® Roofboard" or "DensDeck Dura- Corp."ACFoam II"or"ACFoam III",any thickness,any combinations. GuardTM Roofboard"or 1/2 in.minimum thick gypsum board,with all Membrane: "EverGuard TPO"45 or 60 mil,adhered with"EverGuard butt joints staggered a minimum of 6-in.from butt joints of plywood #1121 Bonding Adhesive"applied at 60-ft2/gal. roof deck. 10. Deck:C-15/32 Incline:1-1/2 Membrane: "EverGuard PVC SR",40-80 mil. Slip Sheet: One layer"VersaShield Underlayment"or"VersaShield 7. Deck:C-15/32 Incline: 1/2 FB-2S". Slip Sheet: Two plies Atlas Roofing"FR 50". Membrane: "EverGuard PVC", 50 to 80 mil, fully adhered with Insulation: minimum 1.5 in. with all butt joints in insulation stag- "EverGuard#2331 Bonding Adhesive"applied at 2-gal/100-ft2 gered a minimum of 6-in.from butt joints in plywood joints Class C-Fully Adhered 1. "EnergyGuard" 1. Deck:C-15/32 Incline:1-1/2 2. "EnergyGuard RA" Gypsum Board(Optional): 1-in.,mechanically fastened. 3. Firestone Building Products"ISO 95+GL" Insulation: Johns Manville "ENRGY 1G" or Rmax Inc. "Ply I" or 4. Atlas Roofing"ACFoam II" "Multi-Max"or Apache Building Products"Pyrox White"or Firestone Membrane: "EverGuard PVC SW',40-80 mil. Building Products"ISO 95+GL"or Atlas Roofing"ACFoam II",11-in. 8. Deck:C-15/32 Incline:1/2 thick minimum Slip Sheet: Two plies Atlas Roofing"FR 50". Membrane: "EverGuard EGFB",(TPA)40 to 100 mil. Membrane: "EverGuard PVC SR",40-80 mil. 2. Deck:NC Incline:1/2 9. Deck:C-15/32 Incline:1/4 Insulation: Atlas Roofing Corp."ACFoam H"or"EnergyGuard RA" Slip Sheet: Two plies Atlas Roofing"FR 50". or wood fiber or glass fiber or perlite,any thickness Insulation: Celotex"Hy-Therm AF",1.5 in.minimum with butt joints Membrane: "EverGuard TPO", 45 to 60 mil, fully adhered with in insulation staggered a minium of 6-in.from butt joints in plywood "EverGuard TPO#1121 Bonding Adhesive"applied at a rate of 60-ft2 roof deck /gal. Membrane: "EverGuard PVC SW',40-80 mil. 3. Deck:C-15/32 Incline:Unlimited 10. Deck:C-15/32 Incline:1/2 Base Sheet: One ply "VersaShield Underlayment" mechanically Primer "Fire Out"at 1 gal/100 ft2. fastened. Base Sheet(Optional): One ply Type G2,mechanically fastened. Membrane: "EverGuard Steep Slope TPO"45 or 60 or 80-mil fully Slip Sheet (Optional): One ply Atlas Roofing Corp. "FR-10" or adhered with"EverGuard Steep Slope Bonding Adhesive"applied at a "FR-50",Elk Corp."VersaShield 1S"or"VersaShield 2S",mechanically rate of 1-gal./100-ft2 or "EverGuard TPO" 45 or 60 or 80-mil fully fastened. adhered with"EverGuard#1121"bonding adhesive applied at a rate of Membrane: "EverGuard TPO",45-80 mil,mechanically fastened. 1-gal./60-ft2 or"EverGuard TPO FB Ultra" (450-800)fully adhered 11. Deck:C-15/32 Incline:1/2 with"EverGuard H2 0 Bonding Adhesive"or"EverGuard®WB 181 Primer. "Fire Out"at lgal/100 ft2. Bonding Adhesive" applied at a rate of 120-ft2 /gal or "EverGuard Base Sheet(Optional): One ply Type G2,mechanically fastened. Freedom TPO"45 or 60 or 80-mil self adhered. Slip Sheet (Optional): One ply Atlas Roofing Corp. "FR-10" or 4. Deck:NC Incline:% "FR-50",Elk Corp."VersaShield 1S"or"VersaShield 2S",mechanically Insulation(Optional): Atlas Roofing"ACFoam II"or"EnergyGuard fastened. RA"or wood fiber or glass fiber or perlite,any thickness. Membrane: "EverGuard PVC SW',40-80 mil,mechanically fastened. Membrane: 45, 60 or 80-mil thick"EverGuard TPO"fully adhered 12. Deck:NC Incline:2-1/2 with"EverGuard Low VOC TPO Bonding Adhesive"applied at a rate Insulation: "EnergyGuard", "EnergyGuard Ultra", "EnergyGuard 1.1-gal./100 ftz. RA", Firestone Building Products Co. "ISO 95+ GL", Atlas Roofing SINGLE PLY MEMBRANE ROOFING SYSTEMS (TPA,PVC and Corp. "ACFoam II",Johns Manville International Inc. "ENRGY 3"or TPO) "EnergyGuard RN"wood fiber,glass fiber or perlite,any thickness. Unless otherwise indicated,the"EverGuard PVC"membrane is Membrane: "EverGuard PVC",50-80 mil,mechanically fastened. mechanically fastened to the deck with one of the following methods: 13. Deck:NC Incline:1/2 "SFS,""Disc Cap."The PVC laps are solvent welded or hot air welded and Slip Sheet(Optional): Any UL Classified Slip Sheet. LOOK FOR THE UL MARK ON PRODUCT • 4- 2011 ROOFING MATERIALS AND SYSTEMS DIRECTORY ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATERIALS(TEVT) 287 Roofing Systems (TGFU)—Continued Roofing Systems (TGFU)—Continued Barrier Board(Optional): minimum Win.thick G-P Gypsum Corp. Membrane: "EverGuard TPO"80 mil,mechanically fastened. "DensDeck®Roofboard"or"DensDeck Prime®Roofboard"or"Dens- 46. Deck:C-15/32 Incline:3/4 Two Deck DuraGuardTM Roofboard" or gypsum wallboard mechanically Sheet:I ulati (Optional): "Ven aShiel FB-1S". t or "EnergyGuard RA" or fawned Slip Sheet(Optional): 1 ply Elk Corp."VersaShield"mechanically Johns Manville International e c."ENRGY 3"or"EnergyGuard RN"or attached. b ergyG d gyG Ultra" y Base Sheet(Optional): 1 ply Type 15 or Type 30 or Type GI or Type thickness. G2,mechanically attached or hot mopped. Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. Membrane: "EverGuard TPO",45-80 mil;or"EverGuard TPO FB 450 47. Deck:NC Incline:5 Ultra"or"EverGuard TPO FB 600 Ultra"or"EverGuard TPO FB 800 Membrane: "EverGuard Steep Slope TPO" or "EverGuard® TPO Ultra". Metallic,"45,60 or 80-mil mechanically fastened. Surfacing: United Solar Ovonics Field-Assembled Photovoltaic 48. Deck:C-15/32 Incline:2 (Solar)Module Systems,"PVL-29,-31,-58, -60,-62,-64,-68,-87, -93, Slip Sheet: One or more plies "VersaShield Solo Fire Resistant -116,-120,-124,-128,-1367 self-adhered. Slipsheet." )eck:NC Incline:1 Insulation: Any UL Classified,any thickness mechanically fastened Barrier Board(Optional): minimum%-in.thick G-P Gypsum Corp. (except EPS). "DensDeck®Roofboard," "DensDeck Prime®Roofboard"or"Dens- Membrane: Any UL Classified(membrane must be currently Classi- Deck DuraGuardTM Roofboard" or gypsum wallboard mechanically fled for use over the insulation used.Actual incline is determined by fastened the existing membrane/insulation Classification, but cannot exceed Slip Sheet(Optional): 1 ply Elk Corp. "VersaShield"mechanically 2:12). attached. 49. Deck:C-15/32 Incline:Unlimited Base Sheet(Optional): 1 ply Type 15 or Type 30 or Type G1 or Type Slip Sheet: One or more plies "VersaShield Solo Fire Resistant G2,mechanically attached or hot mopped. Slipsheet. Membrane: "EverGuard PVC",50-80 mil. Insulation(Optional): Any UL Classified,any thickness(except EPS Surfacing: United Solar Ovonics Field-Assembled Photovoltaic and wood fiberboard). Membrane: Any UL Classified(membrane must be currently Classi- -116,- 20,-12 ,Systems,28,-13 , self-adhered.,-31,-58, 60, -62, -64,-68, -87, 93, fled for use over the insulation used.Actual incline is determined by -eck C-15/32-124, 128, 136,"self adhered. the existing membrane/insulation Classification). Deck:C-15/32 Incline:1-1/2 Slip Sheet: Two layers"VersaShield Underlayment"or"VersaShield 50. Deck:NC Incline:2 FB-2S". Insulation: Polystyrene,EPS or beadboard,any thickness. Membrane: "EverGuard TPO, " 45-60 mil, or "EverGuard PVC," Slip Sheet: One ply"VersaShield Solo Fire Resistant Slipsheet" or 50-80 mil,mechanically fastened. "VersaShield Underlayment." Deck:C-15/32 Incline:1/2 Membrane: Any UL Classified(membrane must be currently Classi- Slip Sheet: Two layers"VersaShield Underlayment"or"VersaShield fled for use over the insulation used.Actual incline is determined by FB 2S" the existing membrane/insulation Classification). Membrane: "EverGuard TPO FB Ultra 450"or"EverGuard TPO FB 51. Deck:C-15/32 Incline:Unlimited Ultra 600",or"EverGuard TPO FB Ultra 800",mechanically attached. Insulation(Optional): Fiberglass,polyisocyanurate,perlite or wood Deck:C-15/32 Incline:1/2 fiber, any thickness mechanically fastened or adhered with any UL Slip Sheet: Three layers"VersaShield FB-1S" Classified insulation adhesive. Insulation: "Energy Guard" or "EnergyGuard Ultra", or "Energy- Barrier Board: Minimum 3-in.thick G-P Gypsum Corp."DensDeck® Guard RA" polyisocyanurate, an thickness, or an classified wood Roofboard" or "DensDeck Prime®Roofboard" or "DensDeck Dura- fiber board. any any GuardTM Roofboard" mechanically fastened with all butt joints stag- Membrane: "EverGuard TPO,"45-80 mil,mechanically fastened. gered a minimum of 6-in.from the plywood deck butt joints. Deck:C-15/32 Incline:3. Membrane: "EverGuard® Steep Slope TPO" or "EverGuard®TPO Slip Sheet: Three layers"VersaShield FB-1S" Metallic,"45,60 or 80-mil mechanically fastened. Insulation: "EnergyGuard RA"or Johns Manville International Inc. 52. Deck:C-15/32 Incline:3 "ENRGY 3"or"EnergyGuard RN"or"EnergyGuard RD"polyisocya- Insulation(Optional): Fiberglass,polyisocyanurate,perlite or wood nurate,any thickness,or any classified wood fiber board. fiber, any thickness mechanically fastened or adhered with any UL Membrane: "EverGuard TPO,"80 mil,mechanically fastened. Classified insulation adhesive. Incline: Barrier Board: Minimum 1A-in. thick United States Gypsum Co. Slip Sheet: Three layers"VersaShield FB-1S". Deck:C-15/32 "SECUROCK®Roof Board" (Type FRX-G)" or"SECUROCK®Glass- Insulation (Optional): "EnergyGuard"or "EnergyGuard RA" or Mat Roof Board"(Type SGMRX)mechanically fastened with all butt Johns Manville International Inc."ENRGY 3"or"EnergyGuard RN"or joints staggered a minimum of 6-in.from the plywood deck butt joints. "EnergyGuard RD"or"EnergyGuard Ultra"polyisocyanurate. Membrane: "EverGuard®TPO Metallic,"45,60 or 80-mil mechani- Membrane: "EverGuard PVC,"50-80 mil,mechanically fastened. cally fastened. . Deck:C-15/32 Incline:2 Class B-Mechanically Fastened Slip Sheet: Two layers"VersaShield Underlayment"or"VersaShield 1. Deck:NC Incline:Unlimited FB-2S". Membrane: "Ever Guard TPO",45-60 mil. Insulation (Optional): "EnergyGuard" or "EnergyGuard RA" or 2. Deck:C-15/32 Incline:1/2 johns Manville International Inc."ENRGY 3"or"EnergyGuard RN"or Slip Sheet: One or more plies of Atlas Roofing"FR50". "EnergyGuard RD" or "EnergyGuard Ultra" polyisocyanurate, any Membrane: "EverGuard TPO",45-60 mil. thickness,or any dassified wood fiber board. 3. Deck:C-15/32 Incline:1/2 Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. Slip Sheet: One or more plies Atlas Roofing"FR 50". Deck:C-15/32 Incline:1/2 Membrane: "EverGuard TPO",45-80 mil. Slip Sheet: Two layers"VersaShield FB-1S". 4. Deck:C-15/32 Incline:1/2 Insulation: "EnergyGuard" or "EnergyGuard Ultra" or "Energy- Slip Sheet: One or more plies Atlas Roofing"FR 10". Guard RA" polyisocyanurate, any thickness, or any classified wood Membrane: "EverGuard TPO",45-80 mil. fiber board. 5. Deck:NC Incline:Unlimited Membrane: "EverGuard TPO"45-80 mil,mechanically fastened. Insulation: Polystyrene,any thickness. Deck:C-15/32 Incline:3/4 Slip Sheet: One ply Atlas Roofing"FR 50". ''*S,lip Sheet: Two layers"VersaShield FB-1S". Membrane: "EverGuard PVC SR",40-80 mil. Insulation: "EnergyGuard RA"or Johns Manville International Inc. 6. Deck:C-15/32 Incline:1/2 "ETNRGY 3"or"EnergyGuard RN"or"EnergyGuard RD"polyisocya- Slip Sheet: ■One layer Atlas Roofing"FR 50". ; nurate,any thickness,or any classified wood fiber board. Membrane: "EverGuard PVC SR",40-80 mil. ` ` LOOK FOR THE UL MARK ON PRODUCT 288 ROOF-COVERING MATERIALS(TEVT) ROOF-COVERING MATERIALS(TEVT) Roofing Systems (TGFU)-Continued Roofing Systems (TGFU)-Continued 7. Deck:C-15/32 Incline:1 Slip Sheet Two plies Atlas Roofing"FR 50 Existing Roof System: Insulated or noninsulated cap,sheet smooth or Membrane: EverGu A PVC SR",40-80 mil. gravel surfaced(loose gravel may be removed). 8. Deck:C 15/32 In 3 Barrier Board(Optional): 1/2-in.thick(minimum)plywood. Primer. 'Tire Out"applied at 1-gal/100 cline: Insulation: "EnergyGuard RA" or Atlas Roofing Corp. "ACFoam II" Membrane: "EverGuazd TPO"or"EverGuard PVC SR", 45-80 mil or mechanically fastened,any thickness. "EverGuard PVC"50-80 mil,mechanically fastened. Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. 9. Deck:NC Incline:2-1/2 3. Deck:C-15/32 Incline:1 Insulation: The Dow Chemical Co. "Hy-Tec" or "Energy-Lok," any Existing Roof System: Insulated or noninsulated cap sheet,smooth or thickness. gravel surfaced bur (gravel may be removed from noncombustible Membrane: "EverGuard PVC"50-80 mil, decks)or PVC roof system,covered with: 10. Deck:NC Incline:3 Barrier Board (Optional): minimum 1/4-in. thick G-P Gypsum Corp. Barrier Board: For standing seam steel decks,2-in. maximum per between the seams. "DensDeck ® Roofboard;' "DensDeck Prime® Roofboard" or "Dens- Deck DuraGuardni Roofboard" Insulation: "EnergyGuard RA"or Atlas Roofing Corp. "ACFoam II" Membrane: "EverGuard PVC"50-80 mi,mechanically fastened. any thickness. Membrane: "EverGuard PVC"50-80 mil. Class B 11. Deck:NC Incline:No Limitations 1. Deck:C-15/32 Incline:1 Insulation: Polyisocyanurate,any thickness. Existing Roof System: Insulated or noninsulated cap sheet smooth or Barrier Board: 1/2-in.thick Johns Manville International Inc."Retro-Fit gravel surfaced (loose gravel may be removed from noncombustible Board." decks)Class B to retain the existing classification is covered with: Membrane: "Ever Guard PVC"50-80 mil. Bather Board: 1/2-in. thick minimum Johns Manville International 12. Deck:C-15/32 Incline: 1/2 Inc Retro-Fit Board." Slip Sheet: One or more plies Atlas Roofing Corp."FR-50." Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. Membrane: "EverGuard PVC"50-80 mil. 2• Deck:C-15/32 Incline:1 13. Deck:C-15/32 Incline:1/2 Existing Roof System: Insulated or noninsulated cap sheet,smooth or Slip Sheet: Two plies Atlas Roofing Corp."FR-10." gravel surfaced BUR (gravel may be removed from noncombustible Membrane: "Ever Guard PVC"50-80 mil. decks) or PVC Class B roof system to retain existing classification 14. Deck:C-15/32 Incline: 1/2 covered with: Slip Sheet: One ply Atlas Roofing Corp,"FR-50." Barrier Board: 1/2-in.thick minimum Johns Manville International Inc. Membrane: "EverGuard PVC"50-80 mil. "Retro Fit Board." 15. Deck:C-15/32 Incline:1-1/2 Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. Slip Sheet: One layer "Versa Shield Underlayment"or "VersaShield Class A,B or C FB-2S"• 1. Deck C-15/32 Incline:1 Membrane: "EverGuard PVC"50-80 mil or"EverGuard TPO"45-60 Existing Roof System: Class A,B or C insulated(any thickness wood fiber,perlite,polyisocyanurate,urethane or polystyrene with a slip sheet) 16. Deck:C-15/32 Incline:1/2 Polyester Fleece: One ply 2.5-oz/yd2(max)polyester fleece. Slip Sheet: One layer VersaShield FB-1S". Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. Membrane: "Ever Guard TPO"45-60 mil. 2. Deck:C-15/32 Incline:1 17. Deck:C-15/32 Incline:2 Existing Roof System: Class A,B or C insulated(any thickness wood Insulation: Polystyrene,EPS or beadboard,any thickness, fiber,perlite,polyisocyanurate,urethane or polystyrene with a slip sheet) Slip Sheet: One or more plies "VersaShield Solo Fire Resistant Slip- Polyester Fleece: One layer 2.5 oz/ dZ max sheet." Y Y ( )polyester fleece. Membrane: Any UL Classified(membrane must be currently Classified Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. 3. Deck:C-15/32 Incline:1 for use over the insulation used. Actual incline is determined by the Existing System: Class A,B or C built-up system,smooth surface,cap existing membrane/insulation Classification,but cannot exceed 2:12). sheet or gravel surfaced, gravel to be maintained at 400-Ib/100 ft2. to Class C-Mechanically Fastened retain existing Classification. Deck:C 15/32 Incline:1/2 Insulation: (Optional)Owens Corning Specialty Products"Foamular," Base Sheet: One or more plies Atlas Roofing "FR 50" mechanically 1 m.max fastened. Y Slip Sheet: 1 ply Altar Roofing Corp. 1 R10 or"FRll." Membrane: One ply"EverGuard TPO White"mechanically Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. Deck:NC Unlimited fastened. SINGLE PLY MEMBRANE SYSTEMS(EPDM) Incline:Unlimited Insulation: "EnergyGuard RA"or Atlas Roofing Corp. "ACFoam II" Class A-Ballasted mechanically fastened,1-in.min. Unless otherwise indicated,the insulation and membrane are laid loosely. Membrane: "as erGuazd PVC"50 80 mil. As an alternate,the insulation may be mechanically fastened to the deck with MAINTENANCE AND REPAIR SYSTEMS(PVC) screws and metal or plastic discs, hot roofing asphalt or a combination of screws/discs and hot roofing asphalt. Class A An optional layer of gypsum board may be placed between the insulation Deck:NC Incline:1/2 and the roof deck on all systems. Existing Roof System: Insulated on noninsulated cap sheet,smooth or As an alternate, the membrane may be adhered to the insulation with gravel surfaced(loose gravel may be removed). "EverGuard EPDM Bonding Adhesive applied to the insulation and to the Barrier Board(Optional): 1/2-in.thick(minimum)plywood membrane at 1-2/3 gal/sq.('Exception:styrene insulations).The lap splices are Insulation/Slip Sheet: (any thickness), sealed with"EverGuard EPDM Splice Adhesive"applied at approximately 150 Perlite/ (optional) 1 ply Atlas icknes Corp. "TR-10." to 175 lineal ft per gal(3-in.lap coated both mating surfaces)or approximately • Perlite (optional)RA"/ 1 ply Atlas Roofing Corp '-10." 130 to 150 lineal ft per gal. (4-in. lap coated both mating surfaces). The laps Rmax"E er Inc. and RA" l ply Atlas Ro Roofing -10". may also be sealed with"EverGuard EPDM 3-in and 7-in.Seam Tape".The Atlas Roofing Corp."ACFoam II"/1 ply Atlas Corp.rp."F Co edges of the laps are sealed with a 3/8-in.by 1-in.bead of"EverGuard EPDM Owens Roofing rp."ACFoam m l /1 ply las or Dow Chemical"R 10." Lap Sealant"or"EverGuard Lap Sealant",(use of lap sealant with splice tapes "Styrofoam SM"/ 1 ply Atlas Roofing Corp.250"or is optional)."EverGuard EPDM LVOC primer"or verGuard EPDM Primer" ppoolyisocyanurate(1.0-in.min)covered by erlite(3/4-in.min)/ may be used with any Classified GAFMC EPDM membrane assembly to (optional)1 ply Atlas Roofing Corp."FR-10." prepare the seam area to receive any EverGuard EPDM Flashing or Seam'Tape BASF EPS(uniform thickness or tapered),covered with perlite(3/4-in. products assembly. uard EPDM Splice Adhesive"and maintain the rating for min) /(optional)1 ply Atlas Roofing Coq)."FR-10." p ( that assembly. ARCO Chemical"I olv Atlas MB"or"ARC6R FM-1,"1.6-in.min As an alternate,river bottom or crushed stone conforming to ASTM D-448 Membrane: "EverGuard PVC"50-80 mil,mechanically fastened. (mi 3 or 24 may be used in lieu of the No.4 stone applied at 10001bs/100 ft2 Deck:NC Incline:3 (minimum). As an alternate,river bottom or crushed stone conforming to ASTM D-448 LOOK FOR THE UL MARK ON PRODUCT OFFICE COPY Product Data Sheet EverGuard® TPO Title 24• , y, Compliant 60 mil Membrane ,.��.•=� Description GAF EverGuard®TPO 60 mil thermoplastic polyolefin single-ply membrane systems have been engineered to provide superior long-term performance and enhanced durability. Strong,flexible EverGuard TPO 60 mil membrane is suitable for use in all types of single-ply systems:Mechanically Attached, Fully Adhered, and Ballast Applied Compared to other heavy-duty single-ply EPDM,PVC and TPO membranes,GAF EverGuard TPO 60 mil roofing membrane provides the benefits of all three materials in a single membrane:low installed cost,heat welded seams,white reflective color,and no liquid plasticizers. Applicable Standards UL approved for use in the construction of Class A,B,or C roofs,FM Approved,ASTM D6878,Dade County Product Approval,ICC-ES Legacy Report#ER-6030 'Physical Properties ASTM Test filelhod AST11116S78111ininuun 'Evil-Guard b pical Test Data 1.Certain data is provided in MD(machine direction)x CMD(cross machine direction)format. 2.Data is based upon typical product performance,and is subject to normal manufacturing tolerance and variance Nominal Thickness ASTM D-751 0.039"(min.) 0.060" Breaking Strength ASTM D-751 Grab Method 220 lbf/in. 320 lbf x 270 lbf Factory Seam Strength ASTM D-751 66 lbf Pass(membrane failure) Elongation at Break ASTM D-751 15% 28% Heat Aging ASTM D-573 90%Retention of Breaking 100% Strength and Elongation at Break Tear Strength ASTM D-751 8"x 8"Sample 55 lbf 70 lbf x 150 lbf Puncture Resistance FTM 1O1C Method 2031 Not Established 380 lbs. Cold Brittleness ASTM D-2137 -40 C -40 C Permeance ASTM E-96 Not Established 0.01 Perms Dimensional Change ASTM D-1204 @158 F,6 hrs. +/- 1% 0.4% Water Absorption ASTM D-47l @158 F, 1 week +/-3.0%(top coating only) 0.7% Hydrostatic Resistance ASTM D-751Method D Not Established 430 psi Ozone Resistance ASTM D-1149 Pass No visible deterioration No visible deterioration @ 7 x magnification @ 7 x magnification Reflectivity ASTM C1549&E408 N/A 0.76 Emissivity ASTM E408 N/A 0.90 Product Data Roll Size Note:Product sizes,dimensions,and widths are nominal values and are subject to normal manufacturing/packaging tolerance and variation Colors Hill Roll Size 3,ull Roll t!'1'eight Half Roll Size Half Roll Weight White,Tan,Gray 10'x 100' 322 lbs. 5'x 100' 162 lbs. (1,000 sq.ft.) (500 sq.ft.) Note:Membrane rolls shipped horizontally on pallets. Storage Store rolls on their sides on pallets or shelving in a dry area Safety Warning Membrane rolls are heavy,and are best positioned and installed by at least two people *White Membrane Only Product Data Sheet 2 14 8300 SW Hunziker St - Google Maps Page 1 of 1 `=ima' ( . -'i. i O l } ` 4 I — 1 0„, .. 83041 s tMjHeuu.v<: ‘4* *, , 4,At. 41q .. .. . .� 110 4 ' 7 ., `: !� 4•tt„.. its. { OFFICE COPY ,adery.2015 Goodie.Map data 02015 Google 50 ft https://www.google.com/maps/place/8300+S W+Hunziker+St,+Tigard,+OR+97223/@45.42... 1/7/2015