Permit 3y q CITY OF TIGARD MECHANICAL PERMIT 4 s COMMUNITY DEVELOPMENT Permit#: MEC2015-00003 T1GARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/05/2015 Parcel: 1 S134BC00403 Jurisdiction: Tigard Site address: 12505 SW NORTH DAKOTA ST OFC Project: Meadow Creek Apartments Subdivision: GREENWOOD TERRACE CONDO Lot: 17 Project Description: Clubhouse/Office-Replace with like kind(2)fan coils. Contractor: ARJAE SHEET METAL CO, INC. Owner: BEL PORTLAND HOLDINGS LLC 8545 SE MCLOUGHLIN BLVD. BY EATON VANCE MANAGEMENT PORTLAND, OR 97222 REIG DIRECTOR OF AASSET MANAGEME 2 INTERNATIONAL PL BOSTON, MA 02110 PHONE: 503-231-7717 PHONE: FAX: 503-230-4888 FEES Specifics: Description Date Amount Type of Use: MF Permit Fee 01/05/2015 $170.37 Class of Work: ALT Type of Const: Plan Review 01/05/2015 $42.59 Occupancy Grp: Occupancy Load: 12%State Surcharge-Mechanical 01/05/2015 $20.44 Stories: Project Valuation: $3,750.00 Fuel Air Handlers Fuel Types: Units<10000 cfm: Gas Pressure: Units>10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $233.40 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility b.T. • . -• Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. Y a obtain a copy of the rules or s•ect questions to •U - •y .Ilin• 503.232.1987 or 1.800.332.2344. Iss ed By: / Permittee Signature: Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit App �1"', v EP FOR OFFICE USE ONLY City of Tigard � " Received Permit No.:�/f -demo 3 • 13125 SW Hall Blvd.,Tigard,OR 97223 Date/By: `( /S Plan Review Phone: 503.718.2439 Fax: 503'598'A °5 2 015 Date/By: Other Permit: T I G A R D Inspection Line: 503.639.4175 J Date Ready/By: Juris: ® See I'age 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information CITY OF TIGARD COMMERCIAL FEE* SCHEDULE — USE CHECKLIST Mechanical permit fees*are based on the value of the work ❑ Nev) construction ® Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑ Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:S Y75 v c; CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ❑ 1-and 2-family dwelling ®Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description I Qty. La. Total .WJOBYFE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address: 12505 SW NORTH DAKOTA STREET Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:TIGARD,OREGON 97223 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:MEADOW CREEK APARTMENTS Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 MAO il C-12...- hydronic)Residential boiler(radiator or 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other. 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert . 33.39 Flue vent for water heater or gas PUSH-PULL TWO FAN COILS fireplace _ 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ❑ PROPERTY OWNER I ❑ TENANT Other: 23.32 Environmental exhaust and ventilation: Name:SAME AS ABOVE Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( I Fax:( ) Attic/crawlspace fans 23.32 181,APPLICANT ® CONTACT PERSON Other: 23.32 Business name:ARJAE SHEET METAL CO. Fuel piping: 514.15 for first four;54.03 for each additional Contact name:LYLE KARGEL JR Furnace,etc. Address:8545 SE McLOUGHLIN BLVD Gas heat pump Wall/suspended/unit heater City/State/ZIP:MILWAUKIE,OREGON 97222 Water heater Phone:(503)231.7717 Fax: :(503)230.4888 Fireplace Range E-mail: Barbecue CONTRACTOR Clothes dryer(gas) Business name:SAME AS ABOVE Other: MECHANICAL PERMIT FEES* Address: Subtotal /7v,37 City/State/ZIP: Minimum permit fee($90.00) Plan review(25%of permit fee) ya,0 Phone:( ) Fax:( ) State surcharge(12%of permit fee) Ao.r/9 CCB lic.:60835 TOTAL PERMIT FEE a.33•YO This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signat • Fee methodology set by Tri-County Building Industry Service Board Print name:CHRIS THOMPSON Date: 1.5.15 FBuilding,Permits,MEC_PetmitApp_0401 I3.doc 440-4617r(11/02/COM/WEB) h-ems e Ur hi-f/lAt SPECIFICATIONS Gas Model No. ML180UH045P24A ML180UH045P36A ML180UH070P24A ML180UH070P36A Heating Model No.-Low Nox --- ML180UH045XP36A --- ML180UH070XP36A Performance 1 AFUE 80% 80% 80% 80% Input-Btuh 44.000 44,000 66,000 66,000 Output-Btuh 35,000 35,000 54,000 54,000 Temperature rise range-°F 20-50 15-45 30-60 30-60 Gas Manifold Pressure(in. w.g.) 3.5/ 10.0 3.5/ 10.0 3.5/ 10.0 3.5/ 10.0 Nat. Gas/LPG/Propane High Static-in.w.g. 0.50 0.50 0.50 0.50 Connections Flue connection-in. round 4 4 4 4 in. Gas pipe size IPS 1/2 1/2 1/2 1/2 Indoor Wheel nom. dia. x width-in. 10 x 7 10 x 8 10 x 7 10 x 8 Blower Motor output-hp 1/5 1/3 1/5 1/3 Tons of add-on cooling 2-3 2-3 1.5-2 2- 3 Air Volume Range-cfm 345- 1130 _ 650- 1670 420- 1160 785- 1660 Electrical Voltage 120 volts-60 h ertz- 1 phase Data Blower motor full load amps 3.1 6.1 3.1 6.1 Maximum overcurrent protection 15 15 15 15 Shipping Data lbs. - 1 package 105 110 114 119 SPECIFICATIONS Iliiiiiiiik. Gas Model No. ML180UH090P36B ML180UH090P48B ML180UH110P48C Heating Model No.-Low Nox --- ML180UH090XP48B --- Performance 1 AFUE 80% 80% 80% Input-Btuh 88,000 88,000 110,000 Output-Btuh 71,000 71,000 89,000 Temperature rise range-°F 25-55 25-55 25-55 Gas Manifold Pressure(in.w g.) 3.5/ 10.0 3.5/ 10.0 3.5/ 10.0 Nat. Gas/LPG/Propane High Static-in.w.g. 0.50 0.50 0.50 Connections Flue connection-in round 4 4 4 in. Gas pipe size IPS 1/2 1/2 1/2 Indoor Wheel nom. dia. x width-in 10 x 9 10 x 10 10 x 10 Blower Motor output-hp 1/3 1/2 1/2 Tons of add-on cooling 2-3 3-4 3-4 Air Volume Range-cfm 680- 1795 920-2160 910-2170 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 6.1 8.2 8.2 Maximum overcurrent protection 15 15 15 Shipping Data lbs. - 1 package 131 183 151 SPECIFICATIONS Gas Model No. ML180UH110P60C ML180UH135P6OD Heating Model No. -Low Nox ML180UH110XP60C --- Performance 1 AFUE 80% 80% Input- Btuh 110,000 132,000 Output- Btuh 89,000 107,000 Temperature rise range-°F 25-55 30-60 Gas Manifold Pressure(in. w.g.) 3.5/ 10.0 3.5/ 10.0 Nat. Gas/LPG/Propane High Static-in. w.g. 0.50 0.50 Connections Flue connection-in round 4 4 in. Gas pipe size IPS 1/2 1/2 Indoor Wheel nom. dia. x width-in 11-1/2 x 10 11 x 11 Blower Motor output-hp 1 1 Tons of add-on cooling 4-5 4-5 Air Volume Range-cfm 1355-2715 1380-2810 Electrical Voltage 120 volts-60 hertz- 1 phase Data Blower motor full load amps 10 11.5 Maximum overcurrent protection 15 15 Shipping Data lbs. - 1 package 161 174 NOTE-Filters and provisions for mounting are not furnished and must be field provided. 'Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations Isolated combustion system rating for non-weathenzed furnaces. ML180UH/Page 7 D 1 EV Si-fh(//�J1 - to e Bryant ENERGY-EFFICIENT / 395CAV INDUCED-COMBUSTION Sizes 045 thru 155 Heating&Gaoling Systems DELUXE UPFLOW F E ries H and J With a unique approach to induced-combustion design, a 40-in. tall cabinet, 4-pass heat exchanger, an inshot burner system, and its safety features, this furnace is without peer. The model 395CAV Deluxe Induced-Combustion Upflow Furnace achieves one of the highest Annual Fuel Utilization Efficiency(AFUE) rat- ings available in a noncondensing,induced-combustion furnace. Its ease and economy of installation,ease of serviceability,eco- nomical initial cost, and short payback time put it in a class well ahead of the competition.The model 395CAV Gas Furnace has the kind of overall performance needed in today's homes. All models are GAMA efficiency rating certified and certified for use \ ► �_` in California Air Quality Management Districts. FEATURES �� EFFICIENCY—The 395CAV Deluxe Induced Combustion Gas �� Furnace provides the efficiency customers want with 80.0 per- c■ ent AFUE. MEDIA FILTER CABINET—Enhanced indoor air quality in your home is made easier with our media filter cabinet—a standard S accessory on all deluxe upflow furnaces. When installed as a part of your system,this cabinet allows for easy and convenient addition of a Bryant high-efficiency air filter. 0 HOT SURFACE IGNITION—This field proven ignition system will save energy and improve reliability. (—� ALUMINIZED HEAT EXCHANGER—The patented 4-pass heat • exchanger is made of aluminized steel and backed by a 20-year Limited Warranty. INTELLIGENT CONTROL BOARD—The 395CAV Furnace has an intelligent control board with an LED status indicator light to ensure top furnace performance. This control board also has a self-test feature that enables the servicing technician to verify 0 operation of the board itself,the inducer,the hot surface ignitor, both high- and low-speed blower operation, and the humidifier. The board also features a 3-amp fuse that protects the trans- former and board. We guarantee the reliability of the control board with a 3-year Limited Warranty. 40-IN. HEIGHT—The 395CAV Deluxe Induced-Combustion Furnace with a 40-in. cabinet height simplifies installation in al- coves,attics,basements(ideal for short basement),closets,and utility rooms, especially with a high-efficiency cooling coil. PREPAINTED CABINET—The 395CAV uses prepainted sheet metal for the cabinet. This is the same high-quality finish found on refrigerators and other appliances today.We ensure its dura- bility by using a galvanized steel substrate to provide superior rust protection. PATENTED BLOCKED VENT SAFEGUARD—Our induced- combustion furnace has a patented blocked vent safeguard.The safeguard will stop furnace operation if the vent system be- comes blocked or is not operating properly.An exclusive with the 395CAV Furnace. EASY INSTALLATION—The model 395CAV has many fea- tures that make installation easier: left or right gas and electrical connections, Molex blower speed selector, matching coil sizes, accessory low-voltage connections, and many more. QUIET OPERATION—A soft mount inducer assembly and slow opening gas valve improves sound level. Form No. PDS 395CAV.40.8 B B. 4 AIRFLOW 2 1/16" 28 A 19" --.....Li VENT CONN 2Vis" �D� f13hs" —Id 1" li 1" I OUTLET ,1 13/is" + 7/8-IN.DIA HOLE 4 0 0 0 Ps IN.DIA + POWER ENTRY 5 3/1i" 1 0 0 = 5 3/s" POWER ENTRY 12 5/16" O O O 7A-IN.DIA o 0 0 2 11/16" I 1 1-IN.DIA ACCESSORY I 5 1 16" o 0 0 5 1316" 0 R.H.GAS ENTRY 0 0 0 ��" 1 3/4-IN.DIA HOLE 0- °o °o °0 2 " (Ns._7/8-IN.DIA ACCESSORY GAS ENTRY = = = 1-IN.DIA HOLE 2 3/B" o °o °0 1/1-IN.DIA THERMOSTAT WIRE ENTRY THERMOSTAT = = WIRE ENTRY V N V a-1 SIDE INLET SIDE INLET 141/2" TYP+1" " +I{��— G +I- �*�* a 11 I 24 5/16" -3"-�I lyis" E 11hs" I` 1" hs" AIR INLET I 5�f I-231/4" TYP SIDE RETURN DUCT LOCATION NOTES: 1. Two additional 7i8-in.dia holes are located in the top plate. 2. Minimum return-air openings at furnace,based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters. 3. Minimum return-air opening at furnace: a. For 800 CFM-16-in.round or 141/2 x 12-in.rectangle. b. For 1200 CFM-20-in.round or 141/2 x 191/2-in.rectangle. c. For 1600 CFM-22-in.round or 141/2 x 231/4-in.rectangle. d. For airflow requirements above 1800 CFM,see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets,a combination of 1 side and the bottom,or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. A98520 DIMENSIONS(In.) MEDIA FILTER CABINET VENT SHIPPING UNIT CONN' WEIGHT SIZE A D E (Dia) (Lb) 2,. a- 024045 14-3/16 12-9/16 11-11/16 4 122 14-3/16 12-9/16 11-11/16 4 124 r—O—T 024070 14-3/16 12-9/16 11-11/16 4 132 036070 14-3/16 12-9/16 11-11/16 4 134 042091 17-1/2 15-7/8 16 4 150 048091 21 19-3/8 18-1/2 4 154 036111 17-1/2 15-7/8 16 4 160 048111 21 19-3/8 18-1/2 4 166 060111 24-1/2 22-7/8 22 4 184 c.,,,,,w;a,,,s„, 048135 21 19-3/8 18-1/2 5t 178 ~5 FI Cabinet A B 060135 24-1/2 22-7/8 22 5t 194 16 17 16. 060155 24-1/2 22-7/8 22 5t 204 m 21 20' 2P 25 24 ' Refer to the furnace Installation Instructions for proper venting procedures. t Oval collar A00309 EFFICIENCY (,G1 Car.•r.0U. RATING Clt DESIGN CERTIFIED ama .6. 414 MEETS DOE RESIDENTIAL CONSERVATION Li*4 00' SERVICES PROGRAM STANDARDS. REGISTERED QUALITY SYSTEM Before purchasing this appliance,read important energy cost and efficiency information available from your retailer. —2— Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 12505 SW NORTH DAKOTA ST OFC, TIGARD, OR, 97223 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2015-00003 Chip Barnett Violation Summary: Inspector Contractor