Loading...
Permit CITY OF TIGARD ELECTRICAL PERMIT 1111 COMMUNITY DEVELOPMENT Permit#: ELC2014-00719 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/05/2015 Parcel: 2S110DC00500 Jurisdiction: TIGARD Site address: 11455 SW SUMMERFIELD DR Project: Schwindt Medical Subdivision: WILLOW-BROOK-FARM Lot: 17 Project Description: Solar photovoltaic system Contractor: NEIL KELLY CO INC Owner: CDBK PROPERTIES LLC 804 N ALBERTA ST 11455 SW SUMMERFIELD DR PORTLAND,OR 97217 TIGARD, OR 97224 PHONE: 503-335-9240 PHONE: FAX: FEES Quantity Description Date Amount 1 ea 5.01 to 15 kva 01/05/2015 $133.56 Specifics: 1 ea 12%State Surcharge- 01/05/2015 $16.03 Electrical Type of Use: COM Class of Work: OTR Type of Const: Occupancy Grp: Total $149.59 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-001 rough••R 952-00 -090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.2( [��322.1987 or 11.800.332.2344. Issued B )♦ — Permittee Signature: `iALA.122 OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. f - > .RECEIVED Electrical Permit Application FOl(OFFI( l Fsr Oyl.' City of Tigard ceived ®� M PermitNo.: . 13125 g DEC f)EC 16 2014 DateB : �� �, /r 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 51.11 1 l IU A u r' Date/B : Other Permit: n�/ ��g I I< A It I) Inspection Line: 503.639.4175 j Y ut G111W Date Ready/By: Juris: 0 See Page 2 for Internet: www.tigard-ocgolUILDING DIVISION Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked below): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. less to ground,or exceeds 14,000 ❑Commercial-use agricultural El 1-and 2-family dwelling ®Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑Multi-family ❑Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived system. ❑Addition of new motor load of ❑"A","E","1-2","1-3", Job no.: 14-71-7120 Job site address;,11A43SW Summerfield Dr 1001W or more. occupancy. ❑Six or more residential units. ❑Recreational vehicle parks. City/State/ZIP:Tigard,OR,97224 iiys J~ ❑Health-care facilities. ❑Supply voltage for more than ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.: Project name: p..mohvb ! - N1?gee -L ❑Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site: Description I Qty. I Fee. I Total I New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: Lot no.: 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft.or portion 33.92 1 Tax map/parcel no.: Limited energy,residential 75.00 2 DESCRIPTION OF WORK (with above sq.ft.) Limited energy,multi-family 75.00 2 Install 9.9kW roof mounted solar electric system residential(with above sq.ft.) Renewable Energy 0 See Page 2 Services or feeders installation,alteration,and/or relocation ® PROPERTY OWNER ❑ TENANT 200 amps or less 100.70 2 201 amps to 400 amps 133.56 2 Name:Brandon Schwindt 401 amps to 600 amps 200.34 2 Address: 11445 SW Summerfield DR 601 amps to 1,000 amps 301.04 2 Over 1,000 amps or volts 552.26 2 City/State/ZIP:Tigard,OR,97224 Temporary services or feeders installation,alteration,and/or Phone:(503)332-8450 Fax:( ) relocation 200 amps or less 59.36 1 Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits—new,alteration,or extension,per panel CO APPLICANT 1 ❑ CONTACT PERSON A.Fee for branch circuits with above service or feeder fee, 7.42 2 Business name:Neil Kelly Company each branch circuit B.Fee for branch circuits without Contact name:Rose Woofenden service or feeder fee,first 56.18 2 branch circuit Address:804 N Alberta St Each add'I branch circuit 7.42 2 City/State/ZIP:Portland,OR,97127 Miscellaneous(service or feeder not included) Each manufactured or modular 67.84 2 Phone:(503)331-9409 Fax::(503)288-7464 dwelling,service and/or feeder • Reconnect only 67.84 2 E-mail: rosew @neilkelly.com Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name:Neil Kelly Company Signal circuit(s)or limited-energy See panel,alteration,or extension. Page 2 2 Address:804 N Alberta St Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr City/State/ZIP:Portland,OR,97217 Investigation(1 hr min) 66.25/hr Phone:(503)331-9409 Fax:(503)288-7464 Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 1663 Electrical Lic.: C984 0l ) uprv.Lie.: 5709S ail//v specifically listed(%hr min) / ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: ( Subtotal: 133.56 Print name: Todd Rhodes Date: 12/8/14 Plan review(25%of permit fee): State surcharge(12%of permit fee): I(P.03 Authorized signature: TOTAL PERMIT FEE: ik l li q.SR This permit application expires if a permit is not obtained within 180 Print name: Rose Woofenden Date: 12/8/14 days after it has been accepted as complete. • Number of inspections allowed per permit. , C\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 05/21/2013 440-46151(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined $75.00 Description I Qty. I Fee I Total 1 • Renewable electrical energy systems: Check Type of Work Involved: 5 kva orless 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 ❑ Burglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with 552.26 2 ❑ Heating, Ventilation and Air Conditioning OAR 918-309-0040) System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 ❑ Each additional inspection over allowable in any of the above: Other: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is 90 00/hr specifically listed('/2 hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system $75.00 Subtotal: 133.56 (SEE OAR 918-309-0000) Plan review,if required(25%of permit fee): State surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 ❑ Audio and Stereo Systems days after it has been accepted as complete. • Number of inspections allowed per permit. ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation (1 Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1.\Building\Permits\ELC_Pern itApp_ELR_ERE.doc Rev 05/21/2013 Voltage rm l Drop per NEC 200 Formula used per NEC 2008 Handbook 215.2(A)(3):VD=21R1`U1000 i■■■ CIRCUIT LOCATION VOLTAGE CURRENT WIRE SIZE tESISTANCE(OHMS PER KF1 LENGTH(FT) VOLTAGE DROP VD% PV ARRAY TO COMBINER 372V 8.94A 10 1.29 60 1.38 V 0.4% COMBINER TO INVERTER 372V 17.88A 8 0.809 50 1.45V 0.4% DEC 16 204 INVERTER TO BREAKER PANEL 240V 38A 8 0.809 10 0.61 V _ 0.3% TOTAL VOLTAGE DROP: 1.0% ^,���-�� NEW NET METER W PROSIDG BY 'w IN EXISTING METER ER B Uit r, 0 h UTILITY ` SERVICE /// /// Y V • v/ 0 • 3/4"CONDUIT 3/4"CONDUIT ---- 3-#8 THWN-2 3-#8 THWN-2 (E) 1-#B THWN-2 GND 1-#6 THWN-2 GND 2X 175A/2P U V MAIN INTEGRATED INVERTER BREAKERS ( V WITH INTEGRATED DC DISCONNECT FUSED COMBINER BOX/ GENERATION • • DISCONNECT METER (N) 50A/2P PV • F____ ,-___ BACKFEED BREAKER • ----•' .� • 00-. AC ri CI M •ice• V V •- /- • • 1 —MIN 1 — G TO EXISTING BUILDING LOADS PV MODULE,TYP. 6-#10 USE-2 1"EMT 3 String of 11 Modules, 1-#6 BARE Cu GND 2-#8 THWN-2 1_ EXISTING 400A Solar World SW275 Mono SECURED TO MODULE FRAMES OR 1-#8 THWN-2 GND _ 240V SINGLE/SPLIT PHASE RACKING — MAIN SWITCHBOARD FOR PROTECTION 1-#6 THWN-2 EXISTING BUILDING GROUNDING GENERAL NOTES CONDUCTOR GROUNDING ELECTRODE ELECTRODE 1)SYSTEM SHALL COMPLY WITH NATIONAL ELECTRIC CODE(NEC) 2)SYSTEM SHALL COMPLY WITH ALL LOCAL,STATE.AND FEDERAL REQUIREMEN' WEATHER DATA FROM WEATHER.COM NEC 890.53 PHOTOVOLTAIC POWER SOURCE LOAD CENTER 3)ALL COMPONENTS SHALL BE GROUNDED PER NEC REQUIREMENTS WEATHER STATION: PORTLAND/HILLSBORO,OR LABEL ON DC DISCONNECT MAIN BREAKER SI; 2X 175A 4)ALL EQUIPMENT SHALL BE LISTED PER NEC LOWEST EXPECTED TEMPERATURE -8.0°C OPERATING CURRENT 26.8A CIRCUIT BREAKER 50 5)TYPE PV WIRE/USE-2/RHW-2 SUPPLIED WIRE FOR ALL OUTDOOR WIRING AVERAGE HOTTEST TEMPERATURE 37.0•C OPERATING VOLTAGE 372.OV BUSBAR 400A 6)TYPE THHHN/THWN-2 SHALL BE USED WHERE IN CONDUIT MAXIMUM SYSTEM VOLTA( 519.6V 7)PER NEC 690.17,A WARNING SIGN SHALL BE PROVIDED AT ALL LOCATIONS•SYSTEM OVERVIEW SHORT CIRCUIT CURRENT 35.9A BACKFED CIRCUIT BREAKER WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE ARRAY RATED DC POWER OUTPUT©I 9900W IS READILY ACCESSIBLE OPEN POSITION.SIGN SHALL READ WARNING-ELECTRIC SHOCK HAZARD-DO NUMBER OF MODULES IN ARRAY 36 LABEL ON AC DISCONNECT NOT TOUCH TERMINALS-TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE #OF MODULES IN SERIES(STRING SIZI 12 AC OUTPUT CURRENT 37.5A ENERGIZED IN OPEN POSITION",OR EQUIVALENT. #OF MODULES IN PARALLEL(#STRING 3 NOMINAL AC VOLTAGE 240V 8)INTERCONNECTION SHALL COMPLY WITH NEC ARTICLE 890.84 PV MODULE RATINGS(§STC INVERTER RATINGS CUSTOMER SCHWINDT MODULE MANUFACTURER SOLARWORLD MANUFACTURER SMA Neil Kelly ADDRESS: 11455 SUMMERFIELD DR. MODULE MODEL#: SW 275 MONO MODEL Sunny Boy 9000TL-US-240V1•11.1101"117 i NM TIGARD,OREGON,97224 RATED MAX POWER OUTPUT 275W RATED AC VOLTAGE 240V OPEN-CIRCUIT VOLTAGE(Voc) 39.4V CEC WEIGHTED EFFICIENC 9800.0% THE INFORMATION ENTIAI: PHOTOVOLTAIC SYSTEM ELECTRICAL SCHEMATIC OPERATING VOLTAGE(Vmp) 31.0V MAX AC POWER OUTPUT 9000W THE DOCUEN IS CONTAINED IN PO N PORTLAND,OR ST, SHORT-CIRCUIT CURRENT(Isc) 9.58A MAX DC VOLTAGE 600V THIS PROPERTY O NT I THE SOLE PORTLAND,OR 97217 SIZE DRAWING DATE: REVISION PROPERTY OF NEIL KELLY.ANY (503)288-7461 8.5 X 11 E1.0 10/3/2014 OPERATING CURRENT(Imp) 8.94A MAX DC CURRENT 27A REPRODUCTION,USE,OR CCB#33716 REV DATE DESCRIPTION SERIES FUSE RATING 15A MIN MPPT INPUT VOLTAGE 300V DISCLOSURE OF THIS DRAWN BY Voc CORRECTION FACTOR(%/deg C) -0.30% MAX MPPT INPUT VOLTAGI 480V INFORMATION IS PROHIBITED MM Vmp/Pmp CORRECTION FACTOR -0.45% MAX AC CURRENT 37.5A WITHOUT THE WRITTEN CONSENT CHECKED BY OF NEIL KELLY Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 11455 SW SUMMERFIELD DR, TIGARD, OR, 97224 Commercial - Electrical 199 Electrical final PASS - No C of O ELC2014-00719 Chip Barnett Violation Summary: Inspector Contractor