Loading...
Report FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT = r Transmittal Letter TIGARD 13125 SW Hall Blvd. •Tigard,Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Dan Nelson DATE I !;14 1!at t • i v u DEPT: BUILDING DIVISION AN 5 2015 FROM: Scott Sullivan CITY OFTIGARD COMPANY: Advanced Alarm Systems Inc. - BUILDING p / 1 k PHONE: 503-290-4091 ` RE: 11945 SW 70th Ave Tigard OR 9722 FPS2014-00151 (Site Address) (Permit Number) TVF&R Station 51 Fir- - a (Project name or subdtvtsto. ame and lot m r ATTACHED ARE THE FO OWING ITEM '. I Copies: I Description: I Copies: I Description: Additional set( of plans. 1 Revisions: Fire Alarm Cross section . and de ils. Wall bracing and/or lateral analysis. Floor/roof t .ming. \ Basement and retaining walls. Beam calf. ations. \\\\ Engineer's calculations. Other(e plain): REMARKS: Owner has requ. 't the ., ange of the fire alarm panel equipment to be Silent Knight opposed to FCI(both a Hone 'ell company). Attached cut sheets and battery calculations. Field to remain identical but SK v rsion(both are made by System Sensor with different labels) FOR O FI E USE ONLY R Routed to Permit Te tc ate: t t Initia A Fees Due: ❑ s ee Descriptio : Amos Amorvl ue: Special Instructions: Reprint Permit(per PE): El Yes ❑ Do Applicant Notified: Date: aee - Initial-P9 1:1Building\Forms\Transmittalt.etter-Revisions.doc 05/25/2012 INTELLIKNIGHT FIRE ALARM CONTROL PANEL Cit of Tigard 101 SILE M, oved Plan IntelliKnight® Model 5700 KNI� cs: Date Single Loop Addressable R Fire Alarm Control System by Honeywell I19 •T The affordable addressable fire �TIS1. alarm control panel solution. IntelliKnight Model 5700 is a class leading single loop addressable fire alarm control/communicator system. 5700 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic IntelliKnight 5700 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 p serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5700 supports SD or SK devices. 5700 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built-in support for up to 50 SK detectors and 50 SK SILL.T modules creating a total point capacity of 100 points AN,GHT • Built in support for up to 50 SD devices 1nlelliKnighe • Up to 125 zones and 125 output groups ""°-� • Uses standard wire—no shielded or twisted pair - required Model 5700 • Built-in digital communicator • Improvements in SKSS deliver five times faster • Central station reporting by point or by zone upload/downloads • Supports Class B (Style 4) and Class A(Style 6 or 7) Built-in RS-232 interface for programming via PC configuration for SLC • Built-in Form C trouble relay rated at 2.5A at 27.4 • Drift compensation VDC • 13 pre-programmed output cadences (including ANSI- • Programmable date setting for Daylight Saving 3.41) and 4 programmable outputs Time • Notification circuits configurable as 1 Class A(Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, Installation constant, or door holder power The 5700 is a surface mount FACP • Built-in synchronization for AMSECO, Gentex®, Compatibility Faraday, System Sensor®and Wheelock®appliances The 5700 signal line circuit (SLC) supports multiple • Built-in annunciator with 80-character LCD display device types of the same protocol: • RS-485 bus provides communication to system • SK accessories • Upload or download programming, event history, or SD detector status onsite or from a remote location using You cannot mix SD and SK SLC devices on a FACP. a PC and 5660 Silent Knight Software Suite (SKSS) • Two built-in Form C programmable relays rated at 2.5A at 27.4 VDC • OFFICE COPY INTELLIKNIGHT FIRE ALARM CONTROL PANEL Model 5700 Fire Alarm Control Panel 0 1'1 J] ® . r . �mw r .4. {amoM . .m �.wTr.. °.41. .r.. ... 4 NO. .a.,r 9 I ruin# V ru.r+srsr.re� 1.111.40, 40 111 4 5496 a. ." . .r, : .. �. 5700 Specifications S-BUS Accessories 5670 Silent Knight Software Suite Electrical 5860/R Remote Fire Annunciator End-user facility management software viewing of detector status and event Primary AC: 120 VAC,60 Hz, 1.5A Features the same 80 character backlit LCD history via modem or direct connection. Total Accessory Load:2.5A @ 27.4 VDC display keypad and firefighter's key switch Notification Power:2.5A @ 27.4 VDC, as the 5700.The system can be fully RBB power-limited programmed and operated from any 5860. Remote Battery Box Accessory Cabinet. Use Standby Current:200 mA 5860 is gray and 5860R is red. if backup batteries are too large to fit into Alarm Current: 365 mA FACP cabinet.Dimensions: Notification/Aux Power Circuits: 5496 Intelligent Power Module 16"W x 10"H x 6"D 2.5A @ 27.4 VDC per circuit, A 6 amp notification power expander that (406 mm W x 254 mm H x 152 mm D power-limited provides four additional power-limited Battery Charging Capacity:7.0-35.0 AH notification appliance circuit outputs. SK-SCK Battery Size:7 AH max.allowed in FACP Seismic Compliance Kit) cabinet. Larger capacity batteries can be 5880 LED/I0 Module housed in an RBB accessory cabinet. Features 40 LED outputs,8 normally open SD505-DTS-K Physical dry contact inputs and one piezo output. Remote test switch that provides remote key Dimensions: 5865-3 and 5865-4 operated test function and annunciation of 12.75"W x 15.2"H x 3.4"D Remote LED Annunciator detector alarm with SD505-DUCTR. (32.39 W x 38.42 H x 8.57 D cm) Features 30 Programmable LED(15 red and SD and SK Devices Weight: 11.5 lbs. (5.2 kg) 15 yellow)outputs and a piezo sounder.The See the data sheets listed below for a 5865-4 adds a silence and reset switch to Color: Red the package. complete listing of the SD and SK devices. Telephone Requirements: 53624 SD Devices data sheet FCC Part 15 and Part 68 approved 5883 Relay Board Features 10 general purpose Form C relays. 53623 SK Devices data sheet Type of Jack: RJ31X(two required) Used with 5880 module. Listings 5824 Serial/Parallel Printer NFPA 13, NFPA 15,NFPA 16,NFPA 70.& Interface Module NFPA 72:Central Station; Remote Provides one parallel and one RS-232 serial Signalling; Local Protective Signalling port for connecting a printer to 5808. Use to Systems;Auxiliary Protected Premises Unit; print a real-time log of system events. &Water Deluge Releasing Service.Suitable detector status reports, and event history. for automatic,manual,waterflow,sprinkler Interfaces with building control system. supervisory(DACT non-coded)signalling Services. Miscellaneous Accessories Other Approvals: UL Listed; 5660 Silent Knight Software Suite CSFM 7170-0559: 144; MEA 429-92-E Vol. User-friendly Windows software for remote XVI;OSHPD(CA)OSP-0065-10 programming of 5700s using a PC. Upload and view panel account information,event history,and detector status. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all P/N 350392 Rev L KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 ©2013 Honeywell International Inc. by Honeywell Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com INTELLIKNIGHT ACCESSORY SILENT 5860 Remote Annunciator KNIGHT by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility Now you can operate and program your IntelliKnight system from up to twelve locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description • Available in red or light gray Features include an 80-character • Support for simultaneous use of backlit LCD providing easy-to- multiple 5860s understand system messages. The • RS-485 interface to panel . annunciator is ergonomically • Operation and appearance is •= , designed with over-sized buttons identical to 5860 built-in • • for the most frequently used annunciator 10°" features, like Reset and Silence. • On-board piezo sounder audibly 111 ...4111* In addition to status messages indicates alarms, troubles, and r � ... • g displayed on the LCD, there are Five ies five LEDs for alarm, supervisory, • Five status LEDs for alarm, W„•. supervisory, trouble, silence and trouble, silence, and AC power AC power conditions status. • Wiring lengths up to 6000 ft. from 5860 The annunciator is available in gray the FACP (depending on wire Environmental to match virtually any decor and gauge and number of devices on Operating Temperature: 32°F– red for applications where the SBUS) 120°F (0°C–49°C) •annunciator must stand out. The UL listed, complies with NFPA 72 Humidity: 10%–93% non- annunciator enclosure can be CSFM approved condensing surface or flush mounted.A trim Electrical Specifications Compatibility ring kit is available for surface Operating Voltage: 24 VDC The 5860 is compatible with the mounting. Standby Current: 20 mA max following FACP's: Features Alarm Current: 25 mA • 5820XL Addressable Fire Control • 80-character backlit LCD display Wiring Distance: 6,000 max. from Panel (4 lines with 20 characters on FACP (depending on wire gauge • 5820XL-EVS Fire Control Panel each line) and number of devices on the with Emergency Voice System • Tactile and audible feedback SBUS) • 5808 Addressable Fire Control • Accepts user codes or fire Panel fighter's key Mechanical Specifications • Larger keypad buttons for system Physical 9.1" W x 7.4" H x 1.5" D • 5700 Addressable Fire Control reset and silence (23.1 W x 18.8 H x 3.8 D cm) Panel • Install up to twelve 5860s per Shipping Weight: 2.8 lbs (1.3 kg) 5820XL/EVS or 5808 system Color • Install up to eight 5860s per 5700 5860R: Red PN 350224 Rev G system ©2014 Honeywell International Inc 5860: Gray INTELLIKNIGHT ACCESSORY 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to 12 remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. Wire Runs Up to 6000 Feet From FACP 11 SBUS "a" tl"" O o"�a®c v utl".� O tltl"a®e m Y04 6 '0 YD" Q Ytl" Otltl � Otlt1 . "Ytl • 0 e 6860 5860 5860 • Up to 12 5860s Per IFP-100/ECS or IFP-1000/ECS System Ink " " •Up to Eight 5860s Per 5700 System Compatible IntelliKnight FACP Listings Ordering Information NFPA 72; UL Listed; 5860R Remote Annunicator four line LCD CSFM 7170-0559: 135; annunciator with 20 characters per line. MEA 429-92-E Vol. IX; Red FM Approved 5860 Remote Annunciator four line LCD annunciator with 20 characters per line. Gray Accessories 5860TR Red Trim Ring for surface mounting 5860TG Gray Trim Ring for surface mounting SILENT This document is not intended to be used for installation purposes.We try to c KNIGHT keep ooct d and ir specific ur applications prduinformation or anticipate up-to-all ate requements.All accurate.specifications We cannot cover are all subject to change without notice. For more information,contact Silent Knight by Honeywell 12 Clintonville Road,Northford,CT 06472-1610.Phone:(800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com Assembled in America Global Project Values: SI1.1..:`.I` Project Name: TVF&R Station 51 Standby Hours: 24 liCli KNIGHT I'I• Project ID: FPS2014-01551 Alarm Mins: 5 Prepared By: Scott Sullivan Advanced Alarm S4 Derating Factor:L 1.2 5700 Calculations Date: 1/5/2015 Voltage Drop Warning Version 08.06 13 Threshold%: 10 Panel ID: 5700 Model: 5700 Add.Fire Alarm Control Panel Max NAC Current: 2.5 Amps Location: Volts: 24 VDC Max Panel Current: 2.5 Amps Ckt.# Circuit Name thy Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL , 5700 5700 CTRL Panel 1 0.200 0.365 SK Photo.Photo-T, PhotoR 8 0.002 0.002 SK Ion 0.000 0.000 SK Heat. Heat-HT,ROR 1 0.000 0.000 SK Beam.Beam-T 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK FIRE-CO 1 0.000 0.007 SK Control 0.000 0.000 SK Control-6 0.000 0.000 SK RelayMon-2 0.000 0.000 SK Monitor, Minimon 3 0.001 0.001 SK Monitor-2 0.000 0.000 SK Monitor-10 0.000 0.000 SK Pull-SA.Pull-DA 6 0.002 0.002 SK Relay 0.000 0.000 SK Relay-6 0.000 0.000 SK Zone 0.000 0.000 „ , SK Zone-6 0.000 0.000 SK Isolator Module 0.000 0.000 B224B1 Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 B200S Intelligent Sounder Base 1 0.000 0.000 B224RB Relay Base 0.000 0.000 RTS151 Magnetic Remote Test 0.000 0.000 RTS151 KEY Key Activated Test 0.000 0.000 RA100Z Remote LED 0.000 0.000 5860 LCD Remote Annunc. 1 0.020 0.025 5824 LCD Remote Annunc. 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-3 LED Annunciator(3G) 0.000 0.000 5865-4 LED Annunciator(4G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 NAC#1 Notification Appl Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% NAC#2 Notification Appl Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.40 _ 0.00% Total Standby Current(Amps) 0.227 0.404 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required 5.440 0.034 Total Alarm AH Required • Total Combined AH Required 5.47 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required_ 6.57 Configure Circuits Print Page FIRE SYSTEM ACCESSORY SILENT Model 5495 KNIGHT Distributed Power Module In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensory'3,Gentexg,AMSECO®, Wheelock and Faraday—what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 to non-essential high-current Distributed Power Module accessories like magnetic door holders The 5495 is a 6 amp notification power • Built-in synchronization for expander that provides its own AC appliances from System power connection, battery charging Sensor®,Gentee',AMSECOw, circuit, and backup battery for use with Wheelock and Faraday fire and security controls such as the Silent Knight Model 5208 Fire Control • Stand alone operation /Communicator.The 5495 is the cost- • Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the costs Americans with Disabilities Act(ADA). Operates with most polarized, UL • The 5495 has built-in ANSI cadence Listed notification devices pattern,which can upgrade older ANSI Cadence pattern output •control panels that lack cadence capability. capability built-in �• A�It.lfl Features Connection to Local Fire Control The 5495 may be connected to a local • UL Listed for 6 amps of notification fire control which utilizes Class A or Model 5495 power Class B type notification circuits Distributed Power Module • Power supply's advanced switch operating between 9 and 32 VDC.The mode design reduces damaging control panel's notification circuit is Approvals heat and manages power up to 50% connected to one of the inputs on the • UL Listed more efficiently than other systems 5495.The control panel's notification • MEA 429-92-E Vol XII • Dip switches allow for easy circuit end-of-line resistor is also • CSFM 7300-0559:123 reconfiguration connected across two terminals on the • • 24 VDC filtered output voltage 5495,which provides supervision NFPA 72 between the 5495 and the fire control • OSHPD (CA)OSP-0065-10 • Four power-limited notification see accessories outputs; 2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual ( ) Class A and 2 Class B notification devices are then connected to the 5495 signal circuits using the • Additional continuous auxiliary 4.7k52 end-of-line resistors provided. output Since the 5495 draws very little power • 3 amps per output circuit from the control, it is possible to • 2 inputs: 2 Class B or 2 Class A connect one 5495 to each notification • Ground fault detector/indicator circuit on the control panel and still • Independent trouble relay provide full supervision of the • AC loss delay option shuts off power notification circuits all the way back to the control panel. FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 —Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 205 mA Battery charging • Low AC power Auxiliary capacity: 35.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification (0° to 49° C) • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B)5495 creates a trouble ) Indicator Lights condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC addition, the 5495 provides a Form @ 3.0 amps each, Aux trouble: Yellow C trouble relay output as an 4.7 k2 EOL Output troubles (1-4): Yellow alternative to using the notification resistor required Ordering Information circuit trouble. on each Class B 5495 Distributed Power Module circuit Electrical Specification Accessories: No. of inputs 2 AC input: 120 VAC at 2 amps SK-SCK Seismic Compliance Kit Input Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA 4ft NI KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350395 Rev F subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road. Northford,CT 06472-7161 Phone:(800)328-0103, Fax: (203)484-7118.For Technical Support, please call 800-446-6444. ■ ww.silentknight.com — Global Project Values: SILENT Project Name: TVF&R Station 51 Standby Hours:I 24 KNIGHT Project ID: FPS2014-00151 Alarm Mins:I 5 Prepared By: Scott Sullivan Advanced Alarm Sy Derating Factor: 1.2 5495 Power Expander Calculations Date: 1/5/2015 1 Voltage Drop Warning Version 02.18.09 Threshold%: 10 Panel ID: Iss5. I Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: lAt FACP I Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AW G Ohms Per Length(ft) Actual Volts @ ° Ckt.# Circuit Name Standby Alarm &Type 1000 Ft. One-Way Ohms EOL °Drop 5495 5495 Pwr Module J 1 0.075 0.205 NAC#1 5495 Circuit 1 0.000 0.845 #14 Solid 2.52 0.00 20.40 0.00% NAC#2 5495 Circuit 2 0.000 1.398 #14 Solid 2.52 0.00 20.40 0.00% NAC#3 5495 Circuit 3 0.000 0.940 #14 Solid 2.52 0.00 20.40 0.00% NAC#4 5495 Circuit 4 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux 5495 Aux Power Out 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% Total Standby Current(Amps). 0.075 3.388 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Required, 1.800 _ 0.282 Total Alarm AH Required Total Combined AH Required 2.08 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.50 Configure Circuits Print Page "`' Circuit Configuration Project Information Project Name: TVF&R Station 51 Project ID: FPS2014-00151 ' Prepared By: Scott Sullivan Advanced Alarm Systems Inc. Date: 1/5/2015 Ckt. Number: NAC#1 Panel ID: 5495 Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 NAC Ckt 1 0.000 0.845 0.000 0.845 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 • 0.000 0.000 Totals 0.000 0.845 Ckt. Number: NAC#2 Panel ID: 5495 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 NAC Ckt 2 0.000 1.398 0.000 1.398 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 _ 1.398 Ckt. Number: NAC#3 Panel ID: 5495 Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 NAC Ckt 2 0.000 0.940 0.000 0.940 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 • 0.000 0.000 Totals 0.000 0.940 Ckt. Number: NAC#4 Panel ID: 5495 Ckt. Name: 5495 Circuit 4 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total • Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 _ 0.000 Ckt. Number: Aux Panel ID: 5495 Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby _ Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 • Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000