Loading...
Permit p CITY OF TIGARD MASTER PERMIT III ' COMMUNITY DEVELOPMENT Permit#: MST2014-00224 T I G AR 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 01/06/2015 Parcel: 1 S 133DA08000 Jurisdiction: Tigard Site address: 12660 SW SNOW BRUSH CT Subdivision: AMART SUMMER LAKE NO.2 Lot: 140 Project: DeMars Project Description: Installation of solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $2,500.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Tema Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: DEMARS,ANDREW W&STEPHANIE SOLARCITY CORPORATION Required Items and Reports(Conditions) 12660 SW SNOW BRUSH CT 6132 NE 112TH AVE TIGARD,OR 97223 PORTLAND,OR 97220 PHONE: 415-310-7352 PHONE: 503-894-6903 FAX: 866-445-7459 Total Fees: $319.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy o'41- - or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. / / Issued By: - `,c— Permittee it ature: zi — i/._ __-..1160•••,• Call . :..t 5 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. M i Building Permit Applica EtV D Residential FOR OFFICE 1'SE 0NLI City of Tigard DEC 18 2014 itD=71 /alJ i ✓_ PermitNo.: ii6rAV 1114 . " 13125 SW Hall Blvd.,Tigard,OR 97223 Plan gw• Phone: 503.718.2439 Fax: 503.5/�� pm�g : r �t� Other Permit: QF HOARD Ic' I I It t� Inspection Line: 503.639.4175 Nl s i Date R- : Aura: HI See Page 2 for Internet: www.tigard-or.gov 1 A{Il�'O," Notified/Method: Soppkmentoal Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® I-and 2-family dwelling ❑Commercial/industrial Valuation: $ 2,500 El Accessory building ❑Multi-family Number of bedrooms: ❑ Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 12660 SW Snow Brush Ct, New dwelling area: square feet City/State/ZIP: Tigard OR 97223 Garage/carport area: square feet Suite/bldgJapt.no.: I Project name: Mars,Andy De Covered porch area: square feet Cross slreeUdirections to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:C'OMMERCL&L-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. PV ROOF MOUNT 2.55 KW Valuation: 5 Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Mars,Andy De Type of construction: Address: 12660 SW Snow Brush Ct, Occupancy groups: City/State/ZIP:Tigard OR 97223 Existing: Phone:(415 ) 310 7352 Fax:( ) New: :r APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* Business name:SOLAR CITY (Pkase coder ra1K schedule) Contact name:MELISSA BENTLEY Structural plan review fee(or deposit): FLS plan review fee(if applicable): Address:6132 NE 112Th AVE Total fees due upon application: City/State/ZIP:PORTLAND OR 97220 Phone:(503)894 6903 I Fax::(1866)445-7459 Amount received: 1 E-mail:ABENTLF.Yta)SOLARCITY.COM PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name:SOLAR CITY Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6132 NE 112Th AVE Solar Installation Specialty Code checklist. City/State/ZIP:PORTLAND OR 97220 Permit Fee(includes plan review 5180 and administrative fees): Phone:(.403)894-6903 I Fax:(1866)445-7459 State surcharge(12%of permit fee): $21.60 CCB lie.:180498 Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained within 180 days after It has been accepted as complete. Print name:A. MELISSA TLE Date: 12/16/14 *Fee methodology set by Tri-County Building Industry Service Board. 1:1Building Wermits\BUP-RESPermitApp.doc 02/24/2011 440.46131(11/02/COM/WEB) Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFRC t: U.SL ONLY City of Tigard d Received 14 g Daldny_ f canal No -r 13125 SW I hill Blvd.,Tigard,OR 97223 -- Phone: 303.718.2439 Pax 503.598.1960 Associated perm iis: i1ti111 24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Platat•init LI Mechanical Internet! www.ligard-or.gov O Oriie, THE FOLLOWING I ENIS ARE. REQU'IRED [OR E'1.N REVIEW 1 es 'u \;It 1 Land use actions con ileted, See urisdictiott criteria for concurrent reviews. ❑ ❑ �7 2 Zonin . Flood lain,solar balance .ints,seismic soils dcsi:nation,historic district.etc. ❑ ❑ ❑ 3 Verification or approved plat/lot. ❑ ❑ 4 Fire district a royal re,aired. Name of district: . ❑ ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity la ❑ • 6 Sewer sermit, ■ ❑ U 7 Water district approval. all ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ■• • • 9 Erosion control 0 plan D permit required. Include drainage-way protection,silt fence design and location of catch- • ❑ ❑ basin protection.etc_ 10 3 Complete sets of legible plans. Must he drawn to scale.showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions:property corner elevations(if ❑ ❑ ❑ there is more than a 4-ff.elevation differential,plan must show contour lines at 2-ff.intervals);location of easements and driveway;footprint of structure(including decks):location ofwells/septic systems;utility locations:direction indicator:lot area building coverage urea;percentage of coverage:impervious area;existing structures on site:and surface drainaee. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ . ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size, location of smoke detectors.water heater, 0 ❑ ❑ furnace,ventilation fans, •lumbin fixtures,balconies and decks 30 inches above radc,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑ floor,wall construction,roof construction. More than one cross section may he required to clearly portray construction. Show details of all wall and roof sheathing,roofing_roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction.thermal insulation.etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade lithe change in grade is greater than four foot at building envelope. Full-size sheet addcndums showin: foundation elevations with cross references are acce table. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations:for non- ID _❑ ❑ prescriptive path analysisprovidc specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing.spacing,and bearing ❑ ❑ 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ■ ❑ ❑ systems,see item 22,"Engineer's calculations." 19 Beans calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss deliln details. ❑ ❑ • 21 Energy Code compliance. identify the prescriptive path or provide calculations. A gas-piping,schematic is required ❑ ❑ ❑ for four or more as'fiances. 22 Engineer's calculations. When required or provided,(i.e..shear wall,root'truss)shall be stamped by an engineer or • ❑ ❑ architect licensed in Ore•on and shall he shown to be ate licablc to the .rolect under review. JURISDICTIONAL SPECIFICS 23 Three 3 site .tans are re.aired for Item I I above. Site•tans must be 8-1/2"x 11"or 11"x 17". 24 Two 2)sets each are re uired for Items 16, 19,20 and 22 above. • EPA 0 25 Buildheg plans shall not contain redlines or tat -ons. "Mirrored"buiidin_ dorms will not be acce'fed. ❑ N] • 26 "Reversed"huildin' •tans must meet criteria outlined in the Permit&S'stem Develo.3neat Fees document. ❑ ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Si le plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard U ❑ ❑ Street'l'ree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑ and rotection measures must be drawn to scale and must include the roject arborist's signature of a .roval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks, patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9. 1995. l:\BuildinglPcrmils113UP-RESPermitApp.sloe 02/242011 440-4613T(1 I/O2/COMv1/WEt3) . r Electrical Permit Application 1 t)It Oil I It I 1 ,, t t., \ City of Tigard 4 tE1I/ED �®A1r� Ptrmitro,: f�'g) 9- - A :� • 13125 SW Hall Blvd.,Tigard,OR 9t Plan Review a Phone 503.718.2439 Fax: 503.598.1 C 1 8 Other Permit 2014 ()aleB i 1 :�R I, Inspection Line: 503.639.4175 Y Date Ready/By. Sin, -, See Page 2 far Internet: www.tigard or.gov CITYOF r,^-,,` Notified/Method. Supplemental Information Tl P1. ()C- tHY1G.,� i 1800d 1L t PLAN REVIEW ❑New construction ®Addition/alterationfrepfactnient Please check all that apply(submit 2 sets of plans wiilems checked below): ❑ Demolition ❑Other: Cl Service or feeder 400 amps or more ❑Building over three mimics where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at ISO volts or ❑Floating buildings. less to ground,or exceeds 14,000 ❑Commercial-use agricultural ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings ❑Multi-family ❑ Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ID E1ergency system larger separately derived system ❑Addition of new motor load of ❑"A "E","I-2 "I-3", Job no.: 9722241 I Job site address: 12660 SW Snow Brush Ct, IOOHP or more. occupancy ❑Six or more residential units ❑Recreational vehicle parks City/State/ZIP: Tigard OR 97223 ❑Health-care facilities. CI Supply voltage for more than ❑Hazardous locations 600 volts nominal. Suite/bldg./apt.no.: Project name: Mars,Andy De ❑Service or feeder 600 amps or more FEE SCHEDULE Cross street/directions to job site: Description I Qty. I Pee, I Taw I • , New residential single-or multi-family dwelling unit. Includes attached garage. Subdivision: I Lot no.: 1,000 sq.ft.or less 168.54 4 Ea.add'1500 sq ft.or portion 33.92 I Tax map/parcel no.: Limited energy,residential DESCRIPTION OF WORK (with above sq.ft.) 75.00 ' - Limited energy,multi-family PV ROOF MOUNT residential(with above sq ft) 75.00 2 Renewable Energy IR See Page 2 Services or feeders installation,alteration,and/or relocation_ 200 am or less 100.70 2 ® PROPERTY OWNER 0 TENANT � 201 amps to 400 amps 133.56 2 Name: Mars,Andy De 401 amps to 600 amps 200.34 2 Address: 12660 SW Snow Brush Ct, 601 amps to 1,000 amps 301.04 2 city/state/L,IP:Tigard OR 97223 Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Phone:( 415 )310 7352 fax:( ) relocation 200 amps or less 59.36 I Owner installation: This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits—new,alteration.or extension,per panel ® APPLICANT I ® CONTACT PERSON A.Fee for branch circuits with above service or feeder fee, Business name:SOLAR CITY CORP each branch circuit 7.42 2 — — B.Fee for branch circuits without Contact name:A. MELISSA BENTLEY service or feeder fee,first 56 18 2 branch circuit Address:6132 NE 112TH AVE Each add'I branch circuit 7.42 _ 2 City/State/ZIP:PORTLAND OR 97220 Miscellaneous(service or feeder not included) Each manufactured or modular 67.84 2 Phone:(503)894 6903 Fax: :(1866)445 7459 dwelling,service and/or feeder Reconnect only 67.84 2 E-mail:ABENTLEY @SOLARCITY.COM Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name:SOLAR CITY CORP. Signal circuits)or limited-energy See panel,alteration,or extension. _ Page 2 2 Address:6132 NE 112TH AVE Each additional inspection over allowable in atsyof the above Additional inspection(1 hr min) 66.251 hr r City/Stale/ZIP:PORTLAND OR 97220 Investigation(I hr min) 66.25!M ('hone:(503)894 6903 I Fax:(1866)445 7459 Industrial plant(I hr min) 71.18/hr Inspections for which no fee is 90.00/hr CCB Lie.: 180498 Electrical Lie.: C562 Suprv.Lie.: 5873S specifically listed(V,hr min) ELECTRI('Al. PERMIT FEES Suprv.Electrician signature,required: 01-1.--,----vs,.._..0.---y....----- Subtotal: Print name: NICHOLAS ARMSTRONG Date: 12/16/14 Plan review(25%ofpermit Ice): - - State surcharge(12!%e of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires If■permit is nos obtained within 180 Print name: A. MELISSA BENTLEY Date: 12116/14 days after it has been accepted as complete. • Number of inspections allowed per permit ItBuildinaPamits\ELC PermitApp_F-1.R ERE dot P..OS/2112013 44O.46191(I1/0SI O84/WEn Electrical Permit Application—City of Tigard Page 2--Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: - >ett%r Fee for all residential systems combined ... $75.00 'a isa- 1 vo'.T Fee ") Total I • Reaewabk ckctrieal energy systems: Check Type of Work Involved: 5 kra or less 10030 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 ❑ Burglar Alarm Wird geawYonsystems is excess of 25 kva: 25.01 to SO kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(foe in accordance with 552.26 2 ❑ Heating,Ventilation and Air Conditioning ontt918-3o90040) System* Solar generation systems in excess of 2S kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspcciion is charged at an hourly(1 hr mtn) 66.25/hr 1 Inspections for which no lee is 90 00r hr sEoaftcaliy listed(S5 h G�J kCJAL ONLY .A t Fee for each commercial system.............. $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review.if required(25%of permit fee): State surcharge(12%of pcmtit fee): Check Type of Work Involved: TOTAL PERMIT FEE: This penait application*spire,if a pnnit is not obtained within 180 ❑ Audio and Stereo Systems days after it hae been accepted as complete. • Number of inspections allowed per permit. ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC El Instrumentation ❑ intercom and Paging Systems ❑ Landscape Irrigation Control* El Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I lkildureremesittELC famflApp EL&Ear due Rev 05/21/2013 FOUNDATION CERTIFICATION MS72c ti" -002240 LOT 26 OF "SOUTH VIEW HEIGHTS" 12o3; 5-Li CITY OF TIGARD, WASHINGTON COUNTY, OREGON LOT 23 LOT 24 S88'26'40'E 40.00' SCALE 1" = 20 FEET RECEIVED �IN IN JAN 0 7 2015 20 0 8 12 16 20 CITY OF TIGARD BUILDING DIVISION 6.0' 29.00' 5.0' 0 LOT 27 0 o LOT 25 b p 1-0 LOT 26 , F _ Q cn 2.50'- 6.0' 19.50' ` 5.0' 9.50' OO N N M _ N88'26'401M 40.00' STE = STREET TREE EASEMENT PUE = PUBLIC UTILITY EASEMENT SW TURNAGAIN DRIVE c— REGISTERED I, ROBERT RETTIG, A REGISTERED PROFESSIONAL LAND SURVEYOR IN THE PROFESSIONAL STATE OF OREGON, HEREBY CERTIFY THAT I HAVE STAKED THE FOUNDATION LAN S U R -YOR FOR LOT 26 OF 'SOUTH VIEW HEIGHTS" WITH HUBS AND TACKS. " PREPARED FOR BEEF BEND ROAD AWAir • "EG o N VENTURE PROPERTIES, INC. DRAWN BY:BRHICHECKED BY:RDRIDWG:3252CSTK 1.106: 3252 JANU RY 11, 2005 4230 SW GALEW00D STREET AKS ENGINEERING & FORESTRY, LLC AAS( ROBERT D. RETTIG SUITE 100 12965 SW HERMAN RD SUITE 100 60124LS LAKE OSWEGO, OR 97035 TUALATIN, OR 97062 www.aks-eng.com RENEWS: 12/31/16 PHONE: 503.563.6151 FAX: 503.563.6152 ` 18 • GeoP ifie Engineering,Inc Real-World Geotechnical Solutions Investigation • Design • Construction Support January 5, 2015 Project No. 12-2704 2, • 24, Stonebri � dge Homes 4230 SW Galewood St., Ste. 100 Lake Oswego, OR 97035 / 033 5 i 4.(/ //46,4/ h) t / Fax 503-387-7615 /� Email Andyt stonebridgehomesnw.corn; JimD(a.stonebridgehomesnw.corn RE: FOUNDATION EXCAVATION REVIEW SOUTH VIEW SUBDIVISION LOT 26 TIGARD, OREGON References: GeoPacific Engineering, Inc., Geotechnical Explorations, Knauss Property Subdivision, 12035 Southwest Beef Bend Road, Washington County, Oregon, report dated August 10, 2012. GeoPacific Engineering Inc. visited the site on yesterday to review the single family home foundation layout on Lot 26. We understand that the proposed building is a two-story garage under style home. In our opinion, the observed subgrade is generally adequate for support to an allowable bearing pressure of 4,000 psf. The expected maximum anticipated total and differential footing movements (generally from soil expansion and/or settlement) are less than 1 inch and 3/4 inch, respectively, over a span of 20 feet. At the time of our site visit, the excavation was nearly complete. The excavation consisted of predominantly soft to medium hard basalt bedrock that could be probed less than 1/4 inch with heavy pressure using a steel "T" bar probe. These soils are considered adequate to support the planned foundation loads. Footing-to-slope setbacks were adequate and foundation embedment depths appeared adequate. Due to rocky and silty soils encountered throughout the site, all foundations should incorporate appropriate drainage measures. Crawlspaces should be provided with a low-point drain and pass through pipes should be installed through footings which would otherwise restrict water flow to the low-point drain. Care should be taken to avoid saturation or disturbance of footing subgrade soils during and after excavation. If footing bearing soils become saturated or disturbed, any softened soil or slough should be removed and replaced with crushed aggregate or additional concrete. 14835 SW 72n°Avenue Tel (503) 598-8445 Portland, Oregon 97224 Fax(503)941-9281 ■ Project No. 12-2704 South View Lot 26 Our work scope pertains to a geotechnical engineer's foundation excavation review only and the conditions existing and exposed at the time of our site visit. Within the limitations of scope, schedule and budget, GeoPacific attempted to execute these services in accordance with generally accepted professional principles and practices in the fields of geotechnical engineering and engineering geology at the time the report was prepared. No warranty, express or implied, is made. If you have any questions, please call. Sincerely, GEOPACIFIC ENGINEERING, INC. <CA�°PfiOre° � , 4.G INt`c 0 OREG•N ✓q7N 23 144 i S D.IMF EXPIRES:06/30/20 James D. Imbrie, P.E., G.E. Geotechnical Engineer - 2