Specifications HILL & DALE ENGINEERING, LLC PO BOX 95 VI DA, OREGON 97488 (541) 868-0667 FAX: (541) 896-9205 Dec. 22,2014 Steven M. Hollis 8c Sons PO Box 231 Westfir, Oregon 97492 RE: 11200 SW Fonner Street,Tigard-MST2014-00198 -Egress window in concrete wall-Job #207-14 It is permissible to install an egress window in the proposed location. The wall is designed as a cantilever wall and the opening will not have an effect on the structural integrity of the wall. A minimum of a 4x6 DF/L#2 header shall be installed at the opening. The window well is to be designed by others. The assumption is that the well will be retaining less than four feet of soil and a design by a design professional is not required. If this assumption is not correct, contact this office. Thank you for this opportunity to be of service. If you have questions regarding this report, feel free to contact us at 541-868-0667. Sincerely, `A,-- . '. , .....9 -SP Fa \ I. t ; 4 . illy _. w 1.4;:!,',%,._' ‘___.„` ..,-;/‹.';,- i Tit/ 7 EWlRrTI0t:..'E•;.': ' . (5 Rick Ralston --.�.'.-..:a.4.-s.,. ---- Pamela S. Hillstrom PE Owner/Manager Owner/Manager Hill & Dale Engineering LLC Hill &Dale Engineering LLC