Report FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT III Transmittal Letter I I G A R I) 13125 SW Hall Blvd. •Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: Pole/ DAT j DEPT: BUILDING DIVISION �]. Gll'' DEC 112014 FROM: JFF - / JEIA- ' CM OFTIGARD COMPANY: II i_ 1 �1 w� 1 thAA 1_! (✓IC, BUILDING DIVISION PHONE: 5—ce.)3 2u ( 3 Q Li By: I RE: t s SJ NO( (0/4V-64— ST/2/0/1/ -odi 7 / tte (Permit (Project name or subdivision .: and lot number) ATTACHED ARE THE FOLLO ' I► , ' A Copies: I Description: fi Copies: I Description: Additional set(s)of pl. I is Revisions: Cross section(s) and de . . Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. „.,e Engineer's calculations. Other(explain): REMARKS: OR O/FFIIE USE ONLY Routed t• 'ermit Technician: ate: ( (l 14_ Initials:�r .I,f Fees I e: ❑ Yes o Fee Description: Amount rue: $ _ $ $ $ Special Instructions: Reprint Permit(per PE): [' Yes []-No one Applicant Notified: Date: Li/ii/1 y Initials:'3-j, I:\Building\Forms\TransmivalLetter-Revisions.doc 05/25/2012 `+1 4 IPWU ENGINEERING INC. RECE1Vp Ph: (503) 810-8309 Email: pwuengineering @comcast.net DEC 11 2014 Field Memo Revision: CITYOFTIGARV Job #: MC14149 BUILDING DIVISION • Date: 12/11/14 Project: Kraiter Garage, 9254 SW North Dakota St. Tigard, OR Kyle, Jeff; As per the attached detail 11 the 9'-3" actual dimension is still okay to meet the code aspect ratio of 3.5 times the width of the panel. Therefore, no change is required as the height is less than the maximum allowable of approximately 10'. The second issue attached the redlined and bubbled detail of 3. Added notes to the as-built condition as per Jeff. Need to add continuous blocking in between the roof rafters and provide edge nailing from the roof sheathing to the blocking. Blocking then needs to be fastened to the beam as shown to complete the lateral load path. Inspector to verify that edge nailing from the 3.5" wall sheathing lap onto the beam from the wall sheathing, and verify edge nailing of wall sheathing to cripple wall bottom plate. Also, verify bottom plate connection to top of beam as shown. ����,r� Sincerely, City of Tigara • • • •voltPlans ByAlt Date 441 IA-- �,�o PRO��, REVISION `co��C':G I N ee,`S�ro • �� �. 19421 PE 2 OFFICE COPY A EGON ,t PHILIP V3 Expires: 06/30/2016 F•' 6- s 1( 3 41 • • • • • • 11101° DOUBLE 2 X TOP PL. 8d NAILS @ 3"D.C. STAGRD. .� PLYWD,NAILING TO TOP PL. AND HEADER • ` >S '�V� . : (2) -SLAP. MST48 STRAPS t I ' (2) - CRIPPLE STUDS I -- (HEADER SUPPORT) 1 & (1). KING STUD • `k SIMPSON HOLDOWN PER 2,,� Pt YWD. SHEATHING pee, SCHEDULE fi� l TO BE ONE SOLID ' ` 1 PCE.Wi NO SPLICES 2 X STUDS PER SCHEDULE z SEE SHEAR WALL SCHED.FOR NAIL OR 3x SPACING • 1 fl�, j SILL PER PLAN C d,�, I1 • n- It J'P.T. 2 X PL. MIN.W/1/2"01k X 10"A,F. II 3x SILLS WHERE OCCURS PER PLAN lI I1' #4 HORIZ. @ 12210.C. W/(2} " - a . I I II. BARS @ TOP OF WALL AS SHOWN Q 4.11 • - Il - . - -Q• l PROVIDE 12"HOOKS @ ALL N - _ _ CORNERS&INTERSECTING WALLS• CONC. FOOTING QL • (2)-#4 DOWELS a FROM SOOTING a j 4 4 a ,.l -- v° a • .. n ii W ,( 11 GARAGE WING FRAMING cote SCALE:N.T.S. .3 tt.5, 4 1 fit/bel' (W/ - kiTthr,4 Frims i > Atz-vva cis mi.c-s.v-e ) iz.Q,15 1 ,2, - /0.0(c, -t, • pL G 1633 I 1., 5s EXTEND SHEARWALL c ih� SHEATHING OVER PRIOR TO I 2 x STUD OR BEAM `'!U P � LEDGER PER PLAN ROOF SHEATHING IF SHEATHING ON INTERIOR OF STUD WALL.ADD CONT. 2 x RAFTER r�� .4 �_/ BLKG. EDGE NAIL SHEATHING BY OTHER lig-�' TO BLKG & LEDGER TQ BLKG. vii pt (fie w/16d @6"0.C. `` f 10 HANGERS re°.c• M 04-1 BY OTHER A t 2 x 10 CON f. LEDGER W/(3) 16 d @ EA. STUD OR ti a @ 6"O.C.AT BEAM BY OTHER ,ti ----�.._0�,�„�_'. LATERAL LOAD PATH @ `1 Vent N FAR LEDGER DETAIL ►• �� , NatLtNG SCALE: N.T.S. SHEAR WALL Roof JA 1(t' Xfv41e -5 AD 0 coNT 6 CSC uc-G — 1.2,41 f" s lAsi-ct!(e4 1,64e 6'oc1 uc4fin6 City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 Location: Inspection Date: 9254 SW NORTH DAKOTA ST, TIGARD, OR, December 10, 2014 at 2:29:52 97223 PM Record Type: Record ID: Residential - Master Permit MST2014-00171 Inspection Type: Inspector: 240 Exterior shearwall David Young Result: FAIL Comments: Provide engineers approval for front garage wings over 8' max to bottom of header and break in panels per shear wall detail S1 prior to framing inspection. Ok to cover except garage wings. Violation Summary: Inspector Contractor PWU ENGINEERING INC. Ph: (503) 810-8309 Email: pwuengineering @comcast.net RECEIVED Field Memo Revision: j� Job #: MC14149 DEC 11 2014 Date: 9/29/14 Project: Kraiter Garage, CITY OFTIGARD 9254 SW North Dakota St. BUILDING DIVISION Tigard, OR Kyle, Jeff; As I discussed with you on the phone Jeff, you may use 2x6 studs at 16" O.C. in lieu of dbl 2x4's for the walls. Sincerely, �� PN��FSs 44.#� �. 19421 PE '9 1, r EGO N ,� A I.Y22 A\*‘v IP `N Expires: 06/30/2016