Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
OBECrorvsUC I City of Tigard ENG1/Vr��s A. . o e• Plans B op, Date l �I. By a - t 1,4( LT0)0�-�- itzeisism_ EUGENE,OR November 19, 2014 Corporate Off co 54 i.633.5090 RECEIVED LAKE OSWEGO,OR OFFICE COPY 50'62^6'.03 Taylor Stockton J.UC J. SALEM,OR Black & Veatch • NOV 2 6 2014 503.599.4'00 5885 Meadows Road, Suite 700 Lake Oswego, OR 97035 CITYOFTIGARD ME.774.5 , 0 BUILDING DIVISION 541.174.5590 Re: LO-Tigard Water Partnership BPS (Bonita Pump Station; VANCOUVER,WA OBEC Job No. 560-20.3 360.3':.239' www.obec.com Dear Taylor: Subject: Deferred Engineering Submittal — Brick Veneer Anchorage Submittal No. 047 Brick veneer materials (brick, mortar, anchors) consists of Submittal 047 and 2 partial resubmittals. The original anchorage of the brick veneer was reviewed by MWA architects. In reviewing that submittal, I noted that spacing to be constructed was not noted. The spacing required was given in the Project Specifications (Section 04200 -3.6.3 and 3.6.4;. In reviewing the specifications, I noted an error in that they didn't conform to current IBC and IBC reference codes. Attached is the anchorage product, corrected spacing required for the HB Latter Eye-Wire anchors selected, and Contractor's acknowledgement to use the revised spacing. This letter should be considered the deferred engineering submittal for anchoring the brick veneer for the Building Department. The proposed structural anchorages for brick veneer are now in conformance with the project structural design criteria, plans, and revised specifications. Please call me if you have any questions. a■ p�. ! i ® Pfi Sincerely, 1 k� .6r .: L , 10,06 Gary '•.yor, PE, SE V r- GER:dsm Sr Project Engineer . 1 q(`• 23 �q' '9�E. WI- Enclosure :2/q/ cc: Nick Robertson, OBEC Andy Howe, OBEC Gary Rayor Subject: FW: BPS -- Deferred Submittals - Brick Veneer Ties Attachments: Capture.PNG From: Gary Rayor Sent: Monday, September 15, 2014 1:53 PM To: Stockton, Taylor Cc: Wei, Ho-ping; Nick Robertson; Andy Howe Subject: RE: BPS - Deferred Submittals - Brick Veneer Ties T aayor: To clarii v the brie!: veneer anz.norage t'e Lpecifi:a:ior:s should reaLi: "04200-3.6.3. Space anchors as indicated, but not more than 16 inches o.c. Horizontally and 16 inches o.c. vertically, with not less than 1 anchor for each 1.77 sq. ft. of wall area. Install additional anchors within 12 inches of openings and at intervals, not exceeding i inches, around perimeter." Additionally delete 04200- 3.6.4. Tr reasoning fn' this s,ecifi.at;on ehangn l! �. Masonry anchors and ties are to be designed and installed based on the Building Code Requirements and Specification for Masonry Structures(TMS 402-11/ACI 530-11/ASCE 5-11). This article will examine code compliant anchors for both masonry walls and for brick veneers. 4, ,3oiint reinforcemerr Ladder and tab type are both permitted. The minimum wire size is nine-gage with the cross-wires to be a maximum of 16 inches on center. Provide minimum six-inch lap splices, and ensure that all ends of the longitudinal wires are embedded in mortar at laps. Joint reinforcement should conform to ASTM A951. 1 .All las, /(7 to • .�'' ,i v.-' :i ft,� , � ., N � r I Tab Type(Pintle alld Eye)Joint Reinforcement +� GOty Ketvoe. PE S: F'trr = et' 4:* fir. . ilk GRavor(aobec.com www.obec.com From: Stockton, Taylor imailto:StocktonTic)bv,com] Sent: Monday, September 15, 2014 1:08 PM To: Gary Rayor Cc: Wei, Ho-ping; Nick Robertson; Andy Howe Subject: RE: BPS - Deferred Submittals - Brick Veneer Ties Zap,': Neese cal!to discuss. Sounds like you suggest Mat_i issue a fie:d orde"to tweai: the s",t cii catiofi. Do I S:1trceduCe.the field order tflir,way: "in order to meet the requirements of the subr. tteci anciiDraye bet we-en the,brick veneer ante the CMU wa:I revise:tic hrici<veneer masonry soecificatic i as follow:%.." And then what is the pate fort,varci here rega ciin the n_ec fora cis erred subm t`azn 2 C. Stopping and Resuming Work: Stop work by racking back units in each course from those in course below; do not tooth. When resuming work, clean masonry surfaces that are to receive mortar, remove loose masonry units and mortar, and wet brick if required before laying fresh masonry. D. Built-in Work: As construction progresses, build in items specified in this and other Sections. Fill in solidly with masonry around built-in items. E. Fill space between steel frames and masonry solidly with mortar unless otherwise indicated. .3.5 MORTAR BEDDING AND JOINTING A. Lay hollow brick as follows: 1. With face shells fully bedded in mortar and with head joints of depth equal to bed joints. 2. With entire units, including areas under cells, fully bedded in mortar at starting course on footings. B. Lay solid masonry units with completely filled bed and head joints; butter ends with sufficient mortar to fill head joints and shove into place. Do not deeply furrow bed joints or slush head joints. C. Tool exposed joints slightly concave when thumbprint hard, using a jointer larger than joint thickness unless otherwise indicated. 3.6 ANCHORING MASONRY VENEERS A. Anchor masonry veneers to wall framing with seismic masonry-veneer anchors to comply with the following requirements:. 1. Embed tie sections in masonry joints. Provide not less than 1 'A" inches of air space between back of masonry veneer and face of sheathing. 2. Locate anchor sections to allow maximum vertical differential movement of ties up and down. 3. Space anchors as indicated but notmore than 18 inches o.c. vertically and 24 inches o.c. horizontally, with not less than 1 anchor for each 2 sq. ft. of wall area. install additional anchors within 12 inches of openings and at intervals, not exceeding 8 inches, around perimeter. 4. Space anchors as indicated, but not more than 16 inches o.c. vertically and 32 inches o.c. horizontally with not less than 1 anchor for each-2 67-sq:ft. Wall aiiti;'kntaiiraditional anchors within 12 inches of openings and at intervals, not exceeding 36 inches, around perimeter. LOTWP - Bonita Pump Station Brick Veneer Masonry Work Order 209 04200- 10 CONFORMED TO BID DOCUMENTS EXTERIOR WALLS 2. Brick veneer with a clear airspace as specified in this masonry, concrete or to stud construction by one of the fol code. lowing methods: 3. Other approved vented claddings. 1. With concrete or masonry backing, anchor ties shall be 1405.4 Flashing.Flashing shall be installed in such a manner not less than 0.1055 inch (2.68 mm) corrosion resistant so as to prevent moisture from entering the wall or to redirect wire,or approved equal, formed beyond the base of the it to the exterior. FIashing shall be installed at the perimeters backing. The legs of the loops shall be not less than 6 of exterior door and window assemblies,penetrations and ter- inches (152 mm) in length bent at right angles and laid minations of exterior Nall assemblies, exterior wall intersec in the mortar joint,and spaced so that the eyes or loops Lions with roofs, chimneys, porches. decks, balconies and are 12 inches (305 mm) maximum on center (o.c.) in similar projections and at built-in gutters and similar Inca hotly directions. There shall be provided not less than a lions where moisture could enter the wall. Flashing with pro. 0.1055-inch (2.68 mm) corrosion-resistant wire tie. or jecting flanges shall be installed on both sides and the ends of approved equal,threaded through the exposed loops for copings,under sills and continuously above projecting trim. every 2 square feet (0.2 m) of stone veneer. This tie shall be a loop having legs not less than 15 inches (381 1405.4.1 Exterior wall pockets.In exterior walls of build- mm) in length bent so that it will lie in the stone veneer ings or structures,wall pockets or crevices in which mois- mortar joint.The last 2 inches(51 mm) of each wire leg Lure can accumulate shall be avoided or protected with shall have a right-angle bend. One-inch (25 mm) mini- caps or drips, or other approved means shall be provided mum thickness of cement grout shall be placed between to prevent water damage. the backing and the stone veneer. 1405.42 Masonry. Flashing and weep holes in anchored 2. With wood stud backing, a 2-inch by 2-inch (51 by 51 veneer shall be located in the first course of masonry mm) 0.0625-inch (1.59 mm) zinc-coated or non-metal- above finished ground level above the foundation wall or lic coated wire mesh with two layers of water-resistive slab, and other points of support. including structural barrier in accordance with Section 1404.2 shall be floors,shelf angles and lintels where anchored veneers are applied directly to wood studs spaced a maximum of 16 designed in accordance with Section 1405.6. inches (406 mm) o.c. On studs. the mesh shall be 1405.5 Wood veneers. Wood veneers on exterior walls of attached with 2-inch long (51 mm) corrosion-resistant buildings of Type I, II. III and IV construction shall be not steel wire furring nails at 4 inches (102 mm) o.c. pro- less than 1 inch (25 mm) nominal thickness,0.438-inch (11.1 viding a minimum 1.125-inch (29 mm) penetration into min) exterior hardboard siding or 0.375-inch (9.5 mm) exte- each stud and with 8d annular threaded nails at 8 inches rior-type wood structural panels or particleboard and shall (203 mm)o.c. into top and bottom plates or with equiv- conform to the following: alent wire ties. There shall be not less than a 0.1055- 1. The veneer shall not exceed 40 feet (12 190 mm) in inch (2.68 mm zinc-coated or nonmetallic coated wire, height above grade. Where fire-retardant-treated wood or approved equal,attached to the stud with a minimum is used•the height shall not exceed 60 feet (18 290 mm) of an 8d (0.120 in. diameter) annular threaded nail for in height above grade. every 2 square feet (0.2 nt2) of stone veneer. This tie shall be a loop having legs not less than 15 inches (381 2. The veneer is attached to or furred from a noncombusti- nun) in length,so bent that it will lie in the stone veneer ble backing that is fire-resistance rated as required by mortar joint.The last 2 inches(51 mm)of each wire leg other provisions of this code. shall have a right-angle bend. One-inch (25 mm) mini 3. Where open or spaced wood veneers (without con- mum thickness of cement grout shall be placed between cealed spaces)are used,they shall not project more than the hacking and the stone veneer. 24 inches(610 mm) from the building wall. 3. With cold-formed steel stud backing.a 2-inch by 2-inch 1405.6 Anchored masonry veneer. Anchored masonry (51 by 51 mm) 0.0625-inch (1.59 mm) zinc-coated or veneer shall comply with the provisions of Sections 1405.6, nonmetallic coated wire mesh with two layers of water- 1405.7. 1405.8 and 1405.9 and Sections 6.1 and 6.2 of TMS resistive barrier in accordance with Section 1404.2 shall 402/ACI 530/ASCE 5. be applied directly to steel studs spaced a maximum of 1405.6.1 Tolerances.Anchored masonry veneers in accor 16 inches (406 mm) o.c. The mesh shall be attached dance with Chapter 14 are not required to meet the toler with corrosion resistant#8 self drilling, tapping screws ances in Article 3.3 Fl of TMS 602/ACI 530.1/ASCE 6. at 4 inches(102 mm)o.c.,and at 8 inches(203 mm) o.c. into top and bottom tracks or with equivalent wire ties. 1405.6.2 Seismic requirements. Anchored masonry veneer located in Seismic Design Category C, D, E or F All screws shall extend through the steel connection a minimum of three exposed threads. There shall be not shall conform to the requirements of Section 6.2.2.10 of less than a 0.1055 inch (2.68 mm) corrosion resistant TMS 402/ACI 530/ASCE 5. wire, or approved equal. attached to the stud with a 1405.7 Stone veneer. Stone veneer units not exceeding 10 minimum of a#8 self-drilling, tapping screw extending inches (254 mm) in thickness shall be anchored directly to through the steel training a minimum of three exposed 306 2012 INTERNATIONAL BUILDING CODE' O 91r l CONSULTING "gb - ENGINEERS EUGENE,OR DATE: November 17, 2014 Corporate Office 541.653.6090 OBEC Job No. 560-20.3 LAKE OSWEGO,OR 50=.620.6103 Submittal No. 047—Rev. 2 SALEM,OR 5p .f8u.c?0:J TO: Stockton Taylor Black & Veatch MEDFORD,OR 5885 Meadows Road, Suite 700 541 7711 SS Lake Oswego, OR 97035 VANCOUVER,WA 36:0.314 22D i www.obec.com Subject: LO-Tigard Water Partnership — Bonita Pump Station — Brick Veneer Masonry Partial Resubmittal Enclosed please find 1 electronic copy each of your shop drawings as follows: No exceptions taken, Dwg. No. Target Veneer Mortar, HB Ladder Eye-Wire Veneer Brick Anchorage Spacing Review corrections noted Resubmittal not required, Dwg. No. Revise and resubmit see remarks, Dwg. No. Review is for general compliance with contract documents. No responsibility is assumed for correctness of dimensions or details. REMARKS: Please feel free to call me if you have any questions. By: Ci Gary yor, PE, SE Sr. Project Engineer GER:dsm Enclosures cc: Andy Howe, OBEC From: Bill Chisholm To: Taylor Stockton-Black&Veatch Cc: Justin Tikka (tikkamasonrv(aomail.coml Subject: RN: BPS-Submittal 047-Spacing of Ties Date: Friday,November 14,2014 10:10:00 AM Taylor, this email confirms that the spacing of the ties will be as specified in the below email. I will attach this email to submittal 47.02 as well. This is the spacing that will be used on the ties between the CMU and the Brick Veneer. Spacing not more than 16 inches o.c. horizontally and 16 inches o.c. vertically, with not less than 1 anchor for each 1.77 sq. ft. of wall area. Install additional anchors within 12 inches of openings and at intervals, not exceeding 16 inches, around perimeter. Bill Chisholm Project Manager (503) 822-5571 Office (503) 822-5572 Fax (503) 747-8445 Cell Billmpacificexc.com Pacific Excavation From: Stockton, Taylor [mailto:StocktonT @bv.com] Sent: Monday, September 15, 2014 2:30 PM To: Bill Chisholm Cc: Jones, Theresa A.; Wei, Ho-ping; Glaze, Greg (GGlaze @BrwnCald.com); Rob Murchison (robm @tigard-or.gov); Wei, Ho-ping Subject: BPS - Submittal 047 - Spacing of Ties Bill, As we just discussed here is something else for you to address when you resubmit with Submittal 47-R1. Lake Oswego •Tigard Water Partnership sharing water connecting communities I0,4,14,,c!Fr 0.9 Submittal - 0047 - 0 Project: 209-Bonita Pump Station (BPS) Description: Brick Veneer Masonry Category: No Exceptions Taken Submittal Data .-. . .. Submitted By: William Chisholm-Pacific Excavation Inc. Date Submitted: 06/24/2014 Directed To: Brown &Caldwell Answered Date: CSI Code 04200.1.2 Returned Date: Revision 0 Closed Date: Current Status: No Exceptions Taken CSI Code si Item# _ _ . ..,._ _,,,. �.:,., Notes .,. ., I ®i Description File Name Submittal 47.00-Brick Veneer Masonry Submittal 47.00-Brick Veneer Masonry Packagel.pdf Notes This is the informational submittals requested in section 04200.1.2. 04200.1.2.A - No Exceptions noted 04200.1.2.B 1. Masonry Units - No Exceptions Noted 2. Cementitious materials- No Exceptions Noted 3. Grout mixes - Make Corrections Noted : -Provide certification that grout mix also meets ASTM C 1329. (reference 04200.2.3.A) -Provide certification that Aggregate for Mortar meets ASTM C 144. (Reference 04200.2.3.B) 4. Anchors, ties and metal accessories - No Exceptions Noted REVIEWED Note: Provide as a follow up to this submittal. ® NO EXCEPTIONS NOTED Per 04200-2.2D.5A: Brick color to be (Standard - Mutual Materials color- El IMPLEMENT AS NOTED "Mauna Loa"). ❑ REVISE AND RESUBMIT ❑ REJECTED This conditional review is limited in scope and not detaied and is only for conformance with the visual design concept set forth in the Contract Documents. The Contractor Is responsible for confirming quantities and quality, verifying dimensions, selecting fabrication procedures and construction techniques. coordinating, and safely performing the work The Archkect has not reviewed and is not responsible for substitutions to or deviations from the Contract Documents not clearly noted by the Contractor and specifically accepted by the Architect In writing ey Ryan Roepke Date. 06.26.14 MWA ARCHITECTS 1of1 Printed on 6/24/2014 5:45:12 PM PMWib his Lox•AIl® Adjustable Joint Reinforcement ���W • 270-2X Ladder Eye-Wire HOHMANN & BARNARD, INC. A Kick-BERKSHIRE HATHAWAY COMPANY Adjustable Reinforcement with 2X-Hook .. .,,1 / �--► \`i ` �6..e i ' PREFABRICATED CORNER .. . ;-1:-.. , The embedded portion of the 2X-Hook Compressed ���' /' is 3/16'0 round wire,satisfying the Legs ~�'%Q��';�G J�•code requirement that the mortar bed ^ �•;•:-0i -p thickness(typimilly 3/8")must be twice • `•`t\ `� the diameter of the wire NEW! \ i 3/16"0 Compressed Leg �1 Zan the Industry is st Stronger" St ndar" \ than the Industry Standard \\ I DRAWINGS FOR ILLUSTRATIVE PURPOSES ONLY PREFABRICATED TEE Hohmann& Barnard's 2X-Hook has been tested and I Eye-Wire Finish: designed to withstand over 200-Ibf, in tension or • 0 Hot-Dip Galvanized I Stainless Steel fl Type 304 1=}Type 316 compression, at maximum allowed offset(ACI 530 Note: H&B recommends Stainless Steef for maximum protection 6.2.2.5.5.4) of 1'/4".These results exceed BIA against corrosion. recommendations and the capabilities of standard Eye-Wire Size: "round wire" hooks/pinties by over 100%,creating a (S)Standard Weight. Eg higher standard for the masonry industry. 9 Gauge Side Rods x 9 Gauge Cross Rods Test results available upon request. (EH)Extra Heavy: 2X-Hook: U.S. Pat.No.8,613,175 ❑ 3/16"0 Side Rocs x 9 Gauge Cross Rods MATERIAL CONFORMANCE f—1 Hohmann&Barnard joint reinforcement products conform to: 1--1 (SHD)S cder Heavy Duly: ASTM A951!A951M(Standard Specification for Steel Wire for Masonry 3116"0 Side Rods x 3116'0 Cross Rods Joint Reinforcement) Block Size:(Std.sizes:4°-18-wall,oiler widths available on specie'request.; ACI!ASCE 530(Building Code Requirements for Masonry Structures) ❑ 4" El 6" Q 8" ❑ 10' Wire(Carbon Steel):Prefabricated from cold-drawn steel wire conforming to ASTM A821A82M ❑ 12" ❑ 14" ❑ 16- Tensile Strength-80,000 p.s.i.I Yield Point-70,000 p.s.i.minimum Note:State cavity and/or Insulation thickness when ordenng. Zinc Coaling: : Compressed Leg 2X-Hook Finish: r Hot-Dip Galvanized after fabrication:ASTM Al531A153M-B2(1.5 oz/ft ) Wire(Stainless Steel):ASTM A580/ASTM 580M AIS'Type 304 12 Hot-Dip Galvanized I Stainless Steel ❑Type 304 ❑Type 316 (Type 316 available on saecial order) Eye-Wire Diameters/Dimensions: Compressed Leg 2X-Hook:Length(Model),3116.0(5mm)wire 9 gauge(.148"or W1.7)or 3.x16"0(.187"or W2.8) Q 3"(300H-2X) n 4-(400H-2X) ❑ 5"(500H-2X) Side Rods and Cross Rods available in any combination of the above. �I Eyes and Hooks are 3116"0 standard. ❑ l 6"(600H-2X) l 7"(700H-2X) Cross Rods welded 16"O.C. First Cross Rods welded 12"in from each IMPORTANT:Since each constructron protect is unique,the app-oona'e selection end to allow lap splices pe-code requirements. and use of any product contained herein must be determined by competent H&B manufactures steel wire products from a minimum of 95% architects.engineers and other appropriate professionals who are familiar wrath the post-consumer recycled material. specific requirements of the project in question. HOHMANN& BARNARD, Inc. Branch/Subsidiary Locations: © HOHMANN & BARNARD, INC, - 2014 30 Rasons Court I Hauppauge,NY 11788 ALABAMA-ILLINOIS-MARYLAND CORPORATE HEADQUARTERS NEW YORK-PENNSYLVANIA-TEXAS T: 800.645.0616 F: 631.234.0683 I UTAH-CANADA www.h-b.com r t t ty 4 ddo W i 4 s f, R ,, 4Y t , 4040 L - 4410 r yy & ,rw F I -.w. A w r- 3 x y `. ti e +., sw SS 1 �� , w - ''"/ '''..,„ k:*.', .', - , .,r..