Permit CITY OF TIGARD BUILDING PERMIT
1111 I COMMUNITY DEVELOPMENT Permit#: BUP2014-00267
13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 11/20/2014
T I G A It D g Parcel: 1 S135BA00102
Jurisdiction: Tigard
Site address: 10100 SW WASHINGTON SQUARE RD A-1
Project: Red Robin Subdivision: OAKBURG Lot: 9
Project Description: (4)new wall signs.
Contractor: RAMSAY SIGNS INC Owner: PPR SQUARE TOO LLC
9160 SE 74TH AVE PO BOX 847
PORTLAND, OR 97206 CARLSBAD, CA 92018
PHONE: 503-777-4555 PHONE:
FAX: 503-777-0220
Specifics: FEES
Description Date Amount
Type of Use: COM
Class of Work: OTR Type of Const: Vg Permit Fee-Additions,Alterations, 11/20/2014 $149.75
Demolition
Occupancy Grp: U Occupancy Load: 12%State Surcharge-Building 11/20/2014 $17.97
Dwelling Units: 0 Plan Review 11/20/2014 $97.34
Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 11/20/2014 $25.00
Bedrooms: 0 Bathrooms: 0 11x17)
Value: $4,576
Floor Areas:
Total Area: 0
Accessory Struct: 0
Basement: 0
Carport: 0
Covered Porch: 0
Deck: 0
Garage: 0
Mezzanine: 0
Total $290.06
Required' Required Items and Reports(Conditions)
Fire Sprinkler: Parapet:
Fire Alarm: Protected Corridors:
Smoke Detectors: Manual Pull Stations:
Accessible Parking: 0
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by callin 03.232.1987 or 1.800.332.2344.
Issued By: Permittee Signature: r` (jt,
.4175 by 7:00 a.m.for the next available in ion date. A
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
,Boil?ing Permit Application
Commercial FOR OFFICE USE ONLY
City of Tigard RECEIVE �;B 1 '/ i - Permit No.: ii#aoI�r,-o0a 6�
• 13125 SW Hall Blvd.,Tigard,OR 97223
Plan �b7
Phone: 503.718.2439 Fax: 503.598.1960 2014
Date/By: f( r� Other Permit:
TIGARD Inspection Line: 503.639.4175 NOV 1 S 2014 Date Ready/By: turn la See Page 2 for
Internet: www.tigard-or.gov Notified/Method: ^� Supplementallnformation
N 1
TYPE OFD'�I va�.?.?, p c IO REQUIRED DATA:1-AND 2-FAMILY DWELLING
7 Permit fees*are based on the value of the work performed.
®New construction V s o ition �
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
❑ 1-and 2-family dwelling ®Commerciallindustrial
Valuation: $
❑Accessory building ❑Multi-family Number of bedrooms:
❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: \o\o o S' ! was\nwnocc sq'd New dwelling area: square feet
City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: \-c A rt\a.1 n Covered porch area: square feet
Cross street/directions to job sie: Deck area square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
() S-tc\\ IN CM s1gnc for red rr tv1 (�) \�0\\\ Valuation: $ "115-1Ul.QU
\C C T�
� Existing building area: square feet
New building area: square feet
❑ PROPERTY OWNER ❑ TENANT Number of stories:
Name:See Attached Type of construction:
Address: Occupancy groups:
City/State/ZIP: Existing:
Phone:( ) Fax:( ) New:
0 APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
Business name:Ramsay Signs Inc.
(Please refer to fee seJiadtrtr)
Structural plan review fee(or deposit):
Contact name:Garrett Gibson
FLS plan review fee(if applicable):
Address:9160 SE 70 Ave
Total fees due upon application:
City/State/ZIP:Portland,OR 97206
Phone:(503)777-4555 I Fax::(503)777-0220 Amount received: aIly
E-mail:
- O ess ( C -@ ram S 0,9 s qnc•can PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mo.lied Photo Voltaic Solar Panel System.
Business name:Ramsay Signs Inc Submit two(2 of roof plan with connection det. =
and fire department . -ss,along with the .1 s rregon
Address:9160 SE 74th Ave Solar Installation Special .e'a ch . '.
City/State/ZIP:Portland,OR 97206 Permit fee(includes r w $180.00
and .• i mstrative fees).
Phone:(503)777-4555 Fax:(503)777-0220
S . -• arge(12%of permit fee): $21.60
CCB lic.:63422 Total fee due upon application: $201.60
Authorized signature: %-.°0t This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name '• 1(N VL S I r l Q S Date: 11 120//Li * Fee methodology set by Tri-County Building Industry
Service Board.
1:\Building\Permits\BUP-COM PermitApp.doc 02/24/2011 440-46131(11/02/COM/WEB)
RECEIVED
NOV 13 2014
BUILDING DIVISION
INTERNALLY ILLUMINATED PAN CHANNEL LETTER
WITH REMOTED TRANSFORMER
_ 5„ \� ,, u 11
1 in TRIMCAP
razz-I a LAG SCREWS WITH
ALUMN.TUBE SPACERS
GLASS TUBE SUPPORTS j eOSAA
NEON ILLUMINATION TRANSFORMER WI
DISCONNECT SWITCH IN
UL LISTED CPA, I' VENTILATED METAL BOX
WITH "G" CUP ><-P
- GTO WIRE
,, ,, �'"—✓ TO TRANSF,
PLASTIC FACE ---
O
J-BOX
120 V.
TO
ALUMINUM RETURNS i IN CONDUIT
AND BACKS D
'/2" CONDUIT
THRU WALL
VoS vex--
DRYVIT WALL
•
RECEIVED
NOV 19 2014
CRY( *'TIGARD
BUILDING DIVISION
INTERNALLY ILLUMINATED PAN CHANNEL LETTER
WITH REMOTED TRANSFORMER
5 , 4,�16
1 in TRIMCAP 4 ea■cin
izza, LAG SCREWS WITH
•" ALUMN,TUBE SPACERS
GLASS TUBE SUPPORTS
NEON ILLUMINATION ---- TRANSFORMER W/
DISCONNECT SWITCH IN
UL LISTED C,PA. i VENTILATED METAL BOX
WITH "G" CUR 6 � -c
Bib = GTO WIRE
TO TRANSF•
PLASTIC FACE --
O
120 V.
ALUMINUM RETURNS TO J-BOX
IN CONDUIT
AND BACKS � L
1/2" CONDUIT
THRU WALL
l5 tb5 Fc (e- Fe/r
DRYVIT WALL may,
I 1
4" ' * 3/8" x 16" PLATE
r ,-.311 I 0y2" THRU HOLE IN THE TS 2.)/2" x ZV2r' V"�I I� ASTM A-36
--AND FIELD DRILLED IN PIPE FOR 03/" 2
18-8 STAINLESS STEEL BOLT — II W/0.34" x 2�/" SLOTS
� TS 2" x 2" xy" WALL ON A 4.66" B.C. FOR
o 0 �
ASTM A-500 Gr. B 05 16" 18-8 STAINLESS
Dr
e O STEEL BOLTS, NUTS A
III• ` /6" WASHERS n )1 .1
1018" ,1 O2.. (1) FOR 638"
PLAN VIEW I f?Y• 18-8 STAINLESS
o a 1 0 o STEEL BOLTS
— i•- i- 17'-11%6" SIGN ___._ —
h - —012'-4" ---------- ------� STEEL NEST PLATE
y" ASTM A-36
,---- 3/8" x 06" PLATE
�' ASTM A-36
18.� W/0.34" x 2.V4- SLOTS
1I II 1
on
ON A 4.66" B.C.
II 11
I II ,1 4•
u__
1-1- —V __Jj
T- a"
II I 11 y !I • — 178"y1 r" I- 1 B"
SIGN [ _ice _--mot, -- -- -- -- _z-,:„-.1,:-;:'=--*"I --::// II ' x. a _--_r� I Oh" (1) FOR ij�"
I� r - --z-e:2):-.!!:73 I %It'�I /�� IB-8 STAINLESS
iN �1- 0.41' --`-- 1 _ - a . I - a /(( !'n STEEL BOLTS__ ___.,.., n II /{_ ,, _ I
'N— 1-- ---I;— ----I -- I --- — — —� •i �. ' ., � ,0 PROp�� It S'Z" x-i6 x Y4" x 3"
- lMa"EG ASTM A-'936 STEEL ANGLE
i •� (PIPE PLATE 01.90" x 0.145
ti " AS1M A-36 ASTM A-252 Gr. 3
I \ / �►,�,p
3.-2" 0.125" THICK 6061-T6 9FY OQ`
ALUMINUM FACE PANEL IYNN •hb4 SITE:
�P IFS &hu • Red Robin
10100 SW Washington Square Road
--4'-8" ——I DEsiGN WIND LOAD; 1.-•--2,-4" Portland, Oregon 97223
Based on the 2010 Oregon Structural Specialty Code SIDE VIEW A 106 Oct II 1 RELEASE,TOR PERMITIINC A.HOGA,1
(2009 IBC) using Exposure C and 100 mph wind speed. MT DAR DIROP M ANROwo
ELEVATION VIEW DESIGN SNOW LOAD: Robert—James & Associates, Inc.
Based on Ground Snow Loods. 12255 West 187th Street. Mokena Illinois 60448-9737
phone: 708-479-8385 lox: 708-179-8395 email: rju370comcasl.net
FASTENER NOTE:
Use 18-8 stainless steel bolls, as listed: wa
Log bogs in wood slugs. 7'-4. x 17'-11" ALUMINUM
Hex bolls with 3" x 3" x 1/4" aluminum angle blocking BACKGROUND SIGN FOR LED CHANNEL LETTERS
with plywood sheet blocking between studs. Atm d J.GREENAN RAN 06 Oct II K"R DRAWING NUMBER SHEET 'REV.
CN11ID H J.HoGAN 0.111 os 00 IF NONE 1410008 1 OF 2 A
RECEIVED
NOV 13 2014
CITY OFTIGARD
BUILDING DIVISION
I I
412"(I)FOR OA"
18-8 STAINLESS N
STEEL BOLTS
— 15'-113/8• —►) )/4.r r, I
TS 2" x Y x 310 4=11 5Y2"B.
WALL 111`7 ASTY A-500 Gr. B
I I` 1 TS x x "WALL
2'-5116" ASTM A-500 Gr. B
1 t --—I
I MOUNTING PLATE
RACEWAY RIBS I TS 73'{ x 7f2'" x 346" WALL
ASTM A-500 Gr. B Is 4" x 2" x y" WALL
_6061-16 ALUMINUM TUBE-
NOTCHED FOR ROLLED
-8'-106•-- _ TUBES
2
_IS 2 " x SF x 3j6" WALI 1
/' ASTM A-500 Or. B
15 2" x 2•x 3j6" WALL , •r
1 ASTM A-500 0r. B " 4
\2 �i / 34" "'
4'- " S'-1-4►3 -T I _ 2.44 j-2- o
, II II nr 1� I I
I -�rff
I'-3• r _ 8'-°'16
L-- in - � 11_ n --•
-r-- -" r 2" x 2 z 1H" WALI.
1'-3" 6'-10312" / 6061 16 ALUMINUM 1001.
1____ ' 6 9 - :--1 -; ELEVATION VIEW : REAR FRAME WORK
I'-B" 4'_ID" S'-1 6'-3. /'-I I" I8" A101.411011.1 RIBS
3. 5" FOfil--16 ALUMINUM
+}
8"
A " l r. i. .
974- f 1YP- ,� -------- -
TS 4" x 2" x y""TALI `\\ ,2" x 2" x yg WALL
4 _'x__.6061-T6 ALUMINUM TUBE 6061-T6 ALUMINUM TUBE 1 •.°PAoF f\
NOTCHED FOR ROLLED / , OFANFA `1�x•
TUBES 1 '•'P1 V - -
ELEVATION VIEW : FRAME WORK �- Robert—James & Associates, Inc.
(. ' 9 4r fig. 12255 Wesl 187th Street, Mokena Illinois 60448-9737
FY LYNN OQ'P/I7 phone: 708-479-8385 lax: 708-479-8395 email: rje370comcasl.net
" .xt 7'-4" x 17'-117/8" ALUMINUM
Exaeaa �1 BACKGROUND SIGN FOR LED CHANNEL LETTERS
DMx"BY J.GREENAN 11" 06 Del 14 SCA( DRAWING NIJMNCR 5NEE 1 RCV,
DIM''W J.NOGAN RAR 06 Otl 14 "a"E 1 410008 2 OF 2 A
Location:
Record Type:
Inspection Type:
Result:
Comments:
Inspection Date:
Record ID:
Inspector:
City of Tigard
13125 SW Hall Blvd.
Tigard, OR 97223 Tel: 503.718.2439
10100 SW WASHINGTON SQUARE RD A-1,
TIGARD, OR, 97223
Commercial - Building
299 Final inspection
PASS - No C of O
BUP2014-00267
Chip Barnett
Violation Summary:
Inspector Contractor