Loading...
Permit CITY OF TIGARD BUILDING PERMIT 1111 I COMMUNITY DEVELOPMENT Permit#: BUP2014-00267 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 11/20/2014 T I G A It D g Parcel: 1 S135BA00102 Jurisdiction: Tigard Site address: 10100 SW WASHINGTON SQUARE RD A-1 Project: Red Robin Subdivision: OAKBURG Lot: 9 Project Description: (4)new wall signs. Contractor: RAMSAY SIGNS INC Owner: PPR SQUARE TOO LLC 9160 SE 74TH AVE PO BOX 847 PORTLAND, OR 97206 CARLSBAD, CA 92018 PHONE: 503-777-4555 PHONE: FAX: 503-777-0220 Specifics: FEES Description Date Amount Type of Use: COM Class of Work: OTR Type of Const: Vg Permit Fee-Additions,Alterations, 11/20/2014 $149.75 Demolition Occupancy Grp: U Occupancy Load: 12%State Surcharge-Building 11/20/2014 $17.97 Dwelling Units: 0 Plan Review 11/20/2014 $97.34 Stories: 0 Height: 0 ft Info Process/Archiving-Sm$0.50(up to 11/20/2014 $25.00 Bedrooms: 0 Bathrooms: 0 11x17) Value: $4,576 Floor Areas: Total Area: 0 Accessory Struct: 0 Basement: 0 Carport: 0 Covered Porch: 0 Deck: 0 Garage: 0 Mezzanine: 0 Total $290.06 Required' Required Items and Reports(Conditions) Fire Sprinkler: Parapet: Fire Alarm: Protected Corridors: Smoke Detectors: Manual Pull Stations: Accessible Parking: 0 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by callin 03.232.1987 or 1.800.332.2344. Issued By: Permittee Signature: r` (jt, .4175 by 7:00 a.m.for the next available in ion date. A This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. ,Boil?ing Permit Application Commercial FOR OFFICE USE ONLY City of Tigard RECEIVE �;B 1 '/ i - Permit No.: ii#aoI�r,-o0a 6� • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan �b7 Phone: 503.718.2439 Fax: 503.598.1960 2014 Date/By: f( r� Other Permit: TIGARD Inspection Line: 503.639.4175 NOV 1 S 2014 Date Ready/By: turn la See Page 2 for Internet: www.tigard-or.gov Notified/Method: ^� Supplementallnformation N 1 TYPE OFD'�I va�.?.?, p c IO REQUIRED DATA:1-AND 2-FAMILY DWELLING 7 Permit fees*are based on the value of the work performed. ®New construction V s o ition � Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ®Commerciallindustrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: \o\o o S' ! was\nwnocc sq'd New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name: \-c A rt\a.1 n Covered porch area: square feet Cross street/directions to job sie: Deck area square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. () S-tc\\ IN CM s1gnc for red rr tv1 (�) \�0\\\ Valuation: $ "115-1Ul.QU \C C T� � Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name:See Attached Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: 0 APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name:Ramsay Signs Inc. (Please refer to fee seJiadtrtr) Structural plan review fee(or deposit): Contact name:Garrett Gibson FLS plan review fee(if applicable): Address:9160 SE 70 Ave Total fees due upon application: City/State/ZIP:Portland,OR 97206 Phone:(503)777-4555 I Fax::(503)777-0220 Amount received: aIly E-mail: - O ess ( C -@ ram S 0,9 s qnc•can PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mo.lied Photo Voltaic Solar Panel System. Business name:Ramsay Signs Inc Submit two(2 of roof plan with connection det. = and fire department . -ss,along with the .1 s rregon Address:9160 SE 74th Ave Solar Installation Special .e'a ch . '. City/State/ZIP:Portland,OR 97206 Permit fee(includes r w $180.00 and .• i mstrative fees). Phone:(503)777-4555 Fax:(503)777-0220 S . -• arge(12%of permit fee): $21.60 CCB lic.:63422 Total fee due upon application: $201.60 Authorized signature: %-.°0t This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name '• 1(N VL S I r l Q S Date: 11 120//Li * Fee methodology set by Tri-County Building Industry Service Board. 1:\Building\Permits\BUP-COM PermitApp.doc 02/24/2011 440-46131(11/02/COM/WEB) RECEIVED NOV 13 2014 BUILDING DIVISION INTERNALLY ILLUMINATED PAN CHANNEL LETTER WITH REMOTED TRANSFORMER _ 5„ \� ,, u 11 1 in TRIMCAP razz-I a LAG SCREWS WITH ALUMN.TUBE SPACERS GLASS TUBE SUPPORTS j eOSAA NEON ILLUMINATION TRANSFORMER WI DISCONNECT SWITCH IN UL LISTED CPA, I' VENTILATED METAL BOX WITH "G" CUP ><-P - GTO WIRE ,, ,, �'"—✓ TO TRANSF, PLASTIC FACE --- O J-BOX 120 V. TO ALUMINUM RETURNS i IN CONDUIT AND BACKS D '/2" CONDUIT THRU WALL VoS vex-- DRYVIT WALL • RECEIVED NOV 19 2014 CRY( *'TIGARD BUILDING DIVISION INTERNALLY ILLUMINATED PAN CHANNEL LETTER WITH REMOTED TRANSFORMER 5 , 4,�16 1 in TRIMCAP 4 ea■cin izza, LAG SCREWS WITH •" ALUMN,TUBE SPACERS GLASS TUBE SUPPORTS NEON ILLUMINATION ---- TRANSFORMER W/ DISCONNECT SWITCH IN UL LISTED C,PA. i VENTILATED METAL BOX WITH "G" CUR 6 � -c Bib = GTO WIRE TO TRANSF• PLASTIC FACE -- O 120 V. ALUMINUM RETURNS TO J-BOX IN CONDUIT AND BACKS � L 1/2" CONDUIT THRU WALL l5 tb5 Fc (e- Fe/r DRYVIT WALL may, I 1 4" ' * 3/8" x 16" PLATE r ,-.311 I 0y2" THRU HOLE IN THE TS 2.)/2" x ZV2r' V"�I I� ASTM A-36 --AND FIELD DRILLED IN PIPE FOR 03/" 2 18-8 STAINLESS STEEL BOLT — II W/0.34" x 2�/" SLOTS � TS 2" x 2" xy" WALL ON A 4.66" B.C. FOR o 0 � ASTM A-500 Gr. B 05 16" 18-8 STAINLESS Dr e O STEEL BOLTS, NUTS A III• ` /6" WASHERS n )1 .1 1018" ,1 O2.. (1) FOR 638" PLAN VIEW I f?Y• 18-8 STAINLESS o a 1 0 o STEEL BOLTS — i•- i- 17'-11%6" SIGN ___._ — h - —012'-4" ---------- ------� STEEL NEST PLATE y" ASTM A-36 ,---- 3/8" x 06" PLATE �' ASTM A-36 18.� W/0.34" x 2.V4- SLOTS 1I II 1 on ON A 4.66" B.C. II 11 I II ,1 4• u__ 1-1- —V __Jj T- a" II I 11 y !I • — 178"y1 r" I- 1 B" SIGN [ _ice _--mot, -- -- -- -- _z-,:„-.1,:-;:'=--*"I --::// II ' x. a _--_r� I Oh" (1) FOR ij�" I� r - --z-e:2):-.!!:73 I %It'�I /�� IB-8 STAINLESS iN �1- 0.41' --`-- 1 _ - a . I - a /(( !'n STEEL BOLTS__ ___.,.., n II /{_ ,, _ I 'N— 1-- ---I;— ----I -- I --- — — —� •i �. ' ., � ,0 PROp�� It S'Z" x-i6 x Y4" x 3" - lMa"EG ASTM A-'936 STEEL ANGLE i •� (PIPE PLATE 01.90" x 0.145 ti " AS1M A-36 ASTM A-252 Gr. 3 I \ / �►,�,p 3.-2" 0.125" THICK 6061-T6 9FY OQ` ALUMINUM FACE PANEL IYNN •hb4 SITE: �P IFS &hu • Red Robin 10100 SW Washington Square Road --4'-8" ——I DEsiGN WIND LOAD; 1.-•--2,-4" Portland, Oregon 97223 Based on the 2010 Oregon Structural Specialty Code SIDE VIEW A 106 Oct II 1 RELEASE,TOR PERMITIINC A.HOGA,1 (2009 IBC) using Exposure C and 100 mph wind speed. MT DAR DIROP M ANROwo ELEVATION VIEW DESIGN SNOW LOAD: Robert—James & Associates, Inc. Based on Ground Snow Loods. 12255 West 187th Street. Mokena Illinois 60448-9737 phone: 708-479-8385 lox: 708-179-8395 email: rju370comcasl.net FASTENER NOTE: Use 18-8 stainless steel bolls, as listed: wa Log bogs in wood slugs. 7'-4. x 17'-11" ALUMINUM Hex bolls with 3" x 3" x 1/4" aluminum angle blocking BACKGROUND SIGN FOR LED CHANNEL LETTERS with plywood sheet blocking between studs. Atm d J.GREENAN RAN 06 Oct II K"R DRAWING NUMBER SHEET 'REV. CN11ID H J.HoGAN 0.111 os 00 IF NONE 1410008 1 OF 2 A RECEIVED NOV 13 2014 CITY OFTIGARD BUILDING DIVISION I I 412"(I)FOR OA" 18-8 STAINLESS N STEEL BOLTS — 15'-113/8• —►) )/4.r r, I TS 2" x Y x 310 4=11 5Y2"B. WALL 111`7 ASTY A-500 Gr. B I I` 1 TS x x "WALL 2'-5116" ASTM A-500 Gr. B 1 t --—I I MOUNTING PLATE RACEWAY RIBS I TS 73'{ x 7f2'" x 346" WALL ASTM A-500 Gr. B Is 4" x 2" x y" WALL _6061-16 ALUMINUM TUBE- NOTCHED FOR ROLLED -8'-106•-- _ TUBES 2 _IS 2 " x SF x 3j6" WALI 1 /' ASTM A-500 Or. B 15 2" x 2•x 3j6" WALL , •r 1 ASTM A-500 0r. B " 4 \2 �i / 34" "' 4'- " S'-1-4►3 -T I _ 2.44 j-2- o , II II nr 1� I I I -�rff I'-3• r _ 8'-°'16 L-- in - � 11_ n --• -r-- -" r 2" x 2 z 1H" WALI. 1'-3" 6'-10312" / 6061 16 ALUMINUM 1001. 1____ ' 6 9 - :--1 -; ELEVATION VIEW : REAR FRAME WORK I'-B" 4'_ID" S'-1 6'-3. /'-I I" I8" A101.411011.1 RIBS 3. 5" FOfil--16 ALUMINUM +} 8" A " l r. i. . 974- f 1YP- ,� -------- - TS 4" x 2" x y""TALI `\\ ,2" x 2" x yg WALL 4 _'x__.6061-T6 ALUMINUM TUBE 6061-T6 ALUMINUM TUBE 1 •.°PAoF f\ NOTCHED FOR ROLLED / , OFANFA `1�x• TUBES 1 '•'P1 V - - ELEVATION VIEW : FRAME WORK �- Robert—James & Associates, Inc. (. ' 9 4r fig. 12255 Wesl 187th Street, Mokena Illinois 60448-9737 FY LYNN OQ'P/I7 phone: 708-479-8385 lax: 708-479-8395 email: rje370comcasl.net " .xt 7'-4" x 17'-117/8" ALUMINUM Exaeaa �1 BACKGROUND SIGN FOR LED CHANNEL LETTERS DMx"BY J.GREENAN 11" 06 Del 14 SCA( DRAWING NIJMNCR 5NEE 1 RCV, DIM''W J.NOGAN RAR 06 Otl 14 "a"E 1 410008 2 OF 2 A Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 10100 SW WASHINGTON SQUARE RD A-1, TIGARD, OR, 97223 Commercial - Building 299 Final inspection PASS - No C of O BUP2014-00267 Chip Barnett Violation Summary: Inspector Contractor