Plans 1 B U � a k2a. l�. 0 00068 1 7. AT ALL EXISTING WALLS REMOVE ALL NAILS SCREWS FASTENERS ETC.LEFT BY PREVIOUS TENANT AND PATCH PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C.CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR REVIEW AND 14. CONTRACTOR TO REMOVE ALL UNUSED DATA A POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION- TENANT IMPROVEMENT�T for 01 00 00 GENERAL DATA HOLES READY FOR PAINT. APPROVAL A FULL DESIGN SCHEMATIC FOR THE TENANT SPACE INCLUDING BOTH NEW/RENOVATED WORK AND SYSTEMS UNUSED DATA BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD �� �� • GENERAL REQUIREMENTS 8. UPON REMOVAL OF ANY WALL BASE MATERIAL,CONTRACTOR TO PREP WALL TO PAINT READY CONDITION. UNTOUCHED BY THE TENANT IMPROVEMENT AS APPLICABLE. INCLUDE THE FOLLOWING: FINISH. #3082 A. DUCTING AND SIZES 15. CONTRACTOR SHALL REMOVE ALL LOW VOLTAGE WIRING(TELEPHONE AND DATA) FROM THE RECEPTACLE TO 'R IN W. HANSON 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE WALL CONSTRUCTION MATERIALS B. SUPPLY AND RETURN LOCATIONS AND CFM THE DISTRIBUTION BOARD. LEAVE PULL STRINGS FROM THE BOX TO THE SPACE ABOVE THE CEILING. A SECTION , 1---3 INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF OREGON AND ALL OTHER STATE OR LOCAL INSTALLATION. C. ROOF EQUIPMENT,SIZES AND LOCATIONS OF THE EXISTING LOW VOLTAGE WIRE MAY BE LEFT IN LIEU OF A PULL STRING. J 'jrj �� ' CODE REQUIREMENTS THAT APPLY. 1. PROVIDE STUDS,TRACKS,BRACING,FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE D. UNITS REQUIRING DUCTED SMOKE DETECTION Inc. CLACKA AS, OREGON, 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING E. THERMOSTAT LOCATIONS AND ZONE/UNITASSOC(AIEDIHEREWITH OFFICE LIGHTING O BUILDING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED WHERE PHYSICAL STRUCTURAL F. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 1. OFFICE LIGHT FIXTURES-LITHONIA 2PM3N G B 3 32 18L M/OLTADVANCE OR EQUAL.(NO SYLVANIA BALLASTS) .F A EXISTING PROPERTIES ARE NOT INDICATED,THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LOADS. DESIGN G. ZONE DIAGRAM 2. RECESSED DOWN LIGHT: RUUD LIGHTING RIFT 6"FLUORESCENT QUAD TUBE 2-13W 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION 0 ALL E FRAMING IN ACCORDANCE WITH AISI SG-673. ( ) v 0'0 CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL.SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED AT COMPLETION OF PROJECT THE HVAC CONTRACTOR IS TO PROVIDE LABEL ON GAS METER WITH TENANT ADDRESS AND Q CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A4461A 446 M GRADE A(33000 PSI)G60. SUITE NUMBER. 28 30 00 ELECTRONIC DETECTION AND ALARM THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC,NATIONAL GYPSUM OR AN HVAC DESIGN STANDARDS PROJECT NARRATIVE 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE APPROVED EQUAL. GENERAL PROJECT #10210 PROJECT CONSISTS OF SELECTIVE REMODEL WORK WITHIN 6,698 SF OF EXSITING OFFICE EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK » THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: FOR HORN/STROBE DEVISES USE"SYSTEM SENSOR"SPECTRALERTADVANCE DEVISES,OR APPROVED EQUAL. 5. STANDARD GYPSUM BOARD SHALL BE 5/8 THICK WITH TAPERED EDGES CONFORMING TO AS TM C-36. AND WAREHOUSE SPACE. WORK SHALL INCLUDE BUT NOT BE LIMITED TO DRYWALV DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 1. 350 SQUARE FOOT PER TON. ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 6. WATER RESISTANT GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES. CONFORMING TO ASTM C-630. METAL STUDS, SUSPENDED CEILINGS, DOORS/FRAMES, PLUMBING,AND PAINTING. ALL Emil LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE SHALL BE THICK WITH S DARE REINFORCED SMOOTH EDGES. PROVIDE DUROCK BRAND 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE AS WELL AS CRITERIA PROVIDED TO PACTRUST BY TENANT PRIOR TO WORK TO MEET ADA REQUIREMENTS. SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 7: CEMENT BACKER BOARD HALL B 1H Q CONSTRUCTION: CEMENT BOARD OR APPROVED EQUAL. 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN THE EXISTING BUILDING A. EXTERIOR EXPOSURE AREAS 8. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047: WORK I NCLUDED BUT PERFORMED UNDER SEP" PERMIT PA I'I STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS B. INTERIOR AREAS,SIZE AND USE Fial INTENSION,THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. WALL CONSTRUCTION EXECUTION C. CONFERENCE/TRAINING ROOMS D. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION AND 24-HOUR PLUMBING WORK 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING SCREWS. USE FIRE PROTECTION SPRINKLERING 7. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET"WALK-OFF MATS"TO WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELE,CIRODES AND SCREW CONNECTIONS SHALL BE 3. PACTRUST PREFERENCE IS ZONES TYPICAL 3-5 TON BASED ON USE&EXPOSURE CRITERIA. ZONE LOADS GREATER HEATING,VENTILATION&AIR CONDITIONING WORK PROTECT EXISTING CARPETS. AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD MATERIALS LIGHTER THAN 18 GA. 11-IAN 5 TONS FOR PACKAGED OR SPLIT SYSTEM EQUIPMENT SHALL BE SPLIT INTO MULTIPLE ZONES. ZONE LOADS ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE °fi r et a - F- 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AS 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS INDICATED IN GREATER THAN 3 TONS FOR VAV OR H2O SOURCE HEAT PUMPS SHALL BE SPLIT INTO MULTIPLE ZONES. � .� E i."' „ L NE NEEDED. LEAST DESIGN INC CALCULATIONS. BUTT WELD JOINTS IN FROM THE EDGE O C CONCRETE SLABS. OR SPLICE WITH STUD INSERTS. FASTENERS SHALL BE AT 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. BUILDING I N FOMATI CAN TENANT INFORMATION 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED COMPANIES 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. /� ,�P 3. CUT STUDS SQUARE AND SETWITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION STUDS OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: 4 C INCLUDE: VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT LEAST TWO FULL 6. UNITS: LENNOX,TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 71/2 TONS SHALL `)r ' 15350 SW SEQUOIA PKWY#300 FaxBack, Inc. A. ANDERSON ROOFING, (503)294-0202 HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE JACK STUDS OVER HAVE SPECIAL APPROVAL BY PACTRUST. (,. �G .t D PORTLAND ORE 97224 B. PACIFIC ROOFING (503)640-3163 OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE STUDS AT CORNERS, BUILDING ' C. GRIFFITH ROOFING (503)643-1596 POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP AND BOTTOM TRACKS BY 7. HVAC UNITS WITH EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCTED SMOKE DETECTION AND BE CONNECTED TO A OCCUPANCY AREAS&LOADS: 10. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. MONITORING STATION WITHIN THE BUILDING. (503)624-6300 (PHONE) DOCK ACCESS AREAS AND COMMON AREA FLOORS TO BE SWEPT OR VACUUMED DAILY. 8. UNIT PLACEMENT 24'MINIMUM TO CENTER FROM ROOF EDGE. MULTI-PLACED UNITS SHOULD BE SYMMETRICALLY IN A 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR THE (503)624-7755(FAX) TYPE AREA OCC. EXITS. d• LINE BASED ON STRUCTURAL CALCULATIONS BY ENGINEER. I�N 11. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT PROJECT. B 5,415 SF 55 OCC 2 �N NOT LIMITED TO COMMON CORRIDORS AND STAIRS,BUILDING ENTRANCES,SUITE ENTRANCES,ETC. THE 9. CURBS: 14"CURBS. ASSEMBLED AND LEVELED TO ROOF ANCHORED TO STRUCTURAL MEMBERS BELOW ROOFING. BLDG.#. BLDG. #10 (pcc234) S-2 1,280 SF 3 OCC 1 • ' 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURERS RECOMMENDATIONS. ' CONTRACTOR WILL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE � `kfl 6,698 SF TOTAL TO CONSTRUCTION ACTIVITIES. 6. FINISH QUALITY: A. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST SELECTED ROOFER. SEE DIVISION 1 'Z f:4 C O cn in SHALL NOT USE GENERAL NOMS THIS PAGE. _ CONST. TYPE.: III-B O� �o� 12. CONTRACTOR TO PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS HALL NO w d'mot' AREA PROCESS TRADE NOMENCLATURE B. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. BUILDING RESTROOM FACILITIES. WAREHOUSE TAPE/FINISH COAT* TIGHT DOUBLE C. CONDENSATE MUST BE TRAPPED AT UNIT. THIS BUILDING HOUSES SEVERAL TENANTS INCLUDING THIS TENANT. THE EXISTING LNG`NO 13. STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT PRE- OFFICE/OTHER AREAS TAPE/2 FINISH COATS'/ SMOOTH FINISH TAPED BUILDING IS A SINGLE STORY BUILDING OF 23 635 SF AND IS FULLY SPRINKLERED. ^^ 10. SEISMICALLY ATTACH UNIT TO CURB IN CODE APPROVED FASHION. CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER USG FIRST COAT SAND AFTER TAPE/FINISH COAT(S) cn M M !I COMMON BUILDING AREA BE USED FOR STORAGE. 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR TEXTURE AND/OR 11. ANY GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN INSIDE OF THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 30 FEET. O O FINISH AS SHOWN ON PLANS. BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND CLAMPED(SS.WORM I 14. CONTRACTOR SHALL KEEP THE ROOF FREE OF DEBRIS(LE.NAILS,SCREWS,BOTTLES,ETC.)AT ALL TIMES. GEAR)- ALLOWABLE AREA 19,000 (IBC TABLE 503) 0 Ax-+w• 15. ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. 8. INSTALL WATER-RESISTANT GYPSUM BOARD AT WALLS WITH WAINSCOT PANELING(RESTROOMS,JANITOR CLOSETS). 12. ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND CORROSION WITH SPRINKLER INCREASE-300% 57,000 SF (IBC 506.3) , 16. CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL,MECHANICAL, 09 53 00 SUSPENDED ACOUSTICAL CEILING OIL BASED PAINT(COLOR GREY). TOTAL ALLOWABLE AREA 76,000 SF ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. 1. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES AS NEEDED. TUNE UP GRID SYSTEM AS NEEDED. 13. LOW VOLTAGE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT EXCEED BEND RADIUS 17. LEAVE THE PROJECTCLEAN AND READY FOR OCCUPANCY. MANUFACTURERS GUIDELINE. 76,000 SF>23,635 SF-NON-SEPARATED OCCUPANCY IS ALLOWED(508.3.2) "BP ES-4"EXPANSION SLEEVE ACCEPTABLE. 18. CONTRACTOR TO CLEAN ADJACENT EXTERIOR AREA,I.E.WALKS,EXTERIOR GLASS,ETC. 14. ECONOMIZER TO MEET CODE AND AS FOLLOWS: j 19. CONTRACTOR TO FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. O9 91 23 PAINTING A. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. 20. PROVIDE"AS-BUILT'DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT' INTERIOR: B. BAROMETRIC RELIEF ON 5-71/2 TON UNITS.C. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED 1. WALLS: D. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. CI-N* W PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS W SHALL BE PROVIDED FOR ALL MECHANICAL,ELECTRICAL AND PLUMBING EQUIPMENT.PACTRUST MAY HOLD a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"'PRIMER. 15. ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. N CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT"DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED AND b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480 WITH 16. DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM 26 GAUGE WIN SUPPLY AIR. EDGES OF SUPPLY AIR SEALED. v APPROVED. A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. DROP CANS TO BE EXTENDED TO WITHIN 2'OF CEILING. ¢'' ivir 21. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDES A COMPLETE, 2. DOORS AND FRAMES: 17. DISTRIBUTION DUCTWORK: -- ------ FUNCTIONING PROJECT INCLUDING ALL GENERAL,MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH W ITH TWO COATS OF SEMI-GLOSS OIL. TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED,REGARDLESS OF A. SPIRAL ONLY IF EXPOSED. Ci b. EXISTING HOLLOW METAL-SAND,FILL IMPERFECTIONS WITH BcONDO,SAND AND PRIME PATCHES WITH ALKYD roroxn PORTLAND ERIE CARMAN WHETHER OR NOT SHOWN ON THE DRAWINGS. PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. B. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. Cm AN c. NEW WOOD-PRIME WITH ALKYD OIL UNDER-CAAIER,SAND,FILL ALL FASTENING HOLES WITH PAINTER'S PUTTY, C. IN NON-CONDITIONED AND SEMI CONDITIONED SPACES, p ra 22. ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.LC:'. D. WRAP CONCEALED SUPPLY DUCTWORK WITH MINIMUM R4.2 INSULATION WITH FS BARRIER. _--_-4---_► 0 t3 ,0 ® r' In I CAULK ALL CRACKS IN CASINGS AND BETW EEN JAMBS AND WALLS USING DAP LATEX CAULK,AND FINISH WITH S/G " THE DOCUMENTS,MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME E. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD HANGERS AND ♦-�" - `-- 23. ALIGN AS USED IN SE D N , OIL ENAMEL. » • ® ®®� ... r PLANE,EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. FULL DIAMETER STRAP UP TO 18 0. LARGER THAN 18 MUST HAVE SADDLE TYPE CLAMP. I-.-t-4-1 '� (.5 3 : d. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS,PRIME AS REQUIRED,AND REPAINT WITH SEMI-GLOSS OIL F. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 DEGREES. t--1-+- 1' 1 IN Ill '' r'1 -'n `` 4 fr 24. DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. ENAMEL. IF FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL AS(REQUIRED,AND RE VARNISH WITH SATIN VARNISH. G. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. tic. 1 ..........AW....... 25. SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES REQUESTED TO THE ARCHITECT OF RECORD WITHIN 3. CEILINGS: H. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE DROP CEILING. = ✓ ill � a TWO WEEKS OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO � � $\ in ' REPLACEMENT AT CONTRACTOR COST. a. EXISTING PLASTER-SAND, SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO ACHIEVE UNIFORM 18. FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TU DIFFUSER. � �.....� - � r� ` ���� - ,. ,.� ,° � a��.104 COVERAGE WITH MILLER'S 6200 OR 4480. (� 19. DIFFUSERS: 8 --�- ',�I �1� �',!"' �' ��6�'�'y �o b. NEW PLASTER-PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR In i 1 L 1 • '� . 26. CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS,MECHANICAL, �� �- = s ;�� 4480. A. SUSPENDED CEILING SYSTEM(T BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN TITUS PCS SUPPLY y`_- , ELECTRICAL AND PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF 11,N0 � � �� f AND TAUS PAR RETURN OR APPROVED EQUAL. t -� -� X X.. j u... COPIES OF ALL SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT 4. GENERAL NOTES: f n" , 1 I 1%i ii••• WILL RETAIN ONE COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. B. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250,RETURN-BAR TYPE-DESIGN TITUS 350; -1i n-----:•=,�, - a. KEEP ALL HARDWARE,HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER SPRAY. EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN 11TUS 50F. -.' 1 _� �`.�' ____ (A ' 27. THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS b. ALL SURFACES TO BE SANDED BETWEEN COATS,PRIOR TO INSTALLATION OF NEXT COAT. C. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS L')CATED IN DUCT AT/OR NEAR CLOSEST WYE BRANCH. .` , CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER c. DURING PROGRESS OF WORK,KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND RAGS AT THE LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE END OF EACH DAY. D. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT COMPLETION, INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING AND 20. THERMOSTAT: ALL EXISTING MERCURY'TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE HONEYWELL BUILDING LOCATION CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE SCRAPING,USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB82:20U1003 WHERE POSSIBLE APPROVED SUBSTITUTE: : APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY e. PROTECT WORK OF OTHER TRADES. TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P3144800 -7 DAY PROGRAMMABLE WITH LOCKOUT I THE ARCHITECT PRIOR TO INSTALLATION. f. PROVIDE'WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. FUNCTION-AUTO CHANGEOVER ONLY MOUNT AT ADA HEIGHT(MAY REQUIRE CHANGING HEIGHT AT"REPLACEMENT" 1 LOCATION MAP 28. THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE LOCATIONS). CONTRACTOR SHALL PROGRAM THERMOSTATS AND BALANCE SYSTEM. Z ALL SERVICE INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT 10 00 00 SPECIALTIES 21. THERMOSTAT A-1 ERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. NOT TO SCALE I TENANTS. 10 2813 REST ROOM ACCESSORIES(MULTI OCCUPANCY) 22. WAREHOUSE HEAT: GENERAL 1. TOILET PARTITIONS: USE ACCURATE,CONCORD SERIES OR HADRIAN MFG. FLOOR AND WALL MOUNT ONLY. FULL A. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE ENERGY CODE (�) 2 t;� (5) {6 j �) 1. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING,ETC.SHALL BE SLEEVED THROUGH A CANTILEVER ONLY. NO CEILING ATTACHMENT OR HEAD RAIL OVER'.DOORS. USE PLASTIC LAMINATE PARTITIONS REQUIREMENTS. PROVIDE ADJUSTABLE T STAT FOR EACH UNIT. I 27-e• 5'-0• �V-6' lo. 2T-b' .1 2V-D• 2,CY LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VOLKUM CAULKING. WHERE PORCELAIN TILE OCCUR. I _r A MINI __ SILICONE SEALANT NOT PERMITTED. 23. EXHAUST FANS: �____ _ _ 2. TOILET SEAT COVER DISPENSER AND TOILET TISSUE DISPENSER B�OBRICK B 347 MEN'S (MOUNTS IN PARTITION) MUM PERFORMANCE TO MEET THE CURRENT CODE (J , A. CEILING MOUNTED EXHAUST FANS SHALL HAVE 08 10 00 DOORS AND WINDOWS 3. TOILET SEAT COVER DISPENSER AND TOILET TISSUE DISPENSER BOBRICK B-3474 MEN'S (MOUNTS SIDE WALL OF REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR.COOK GEMINI SERIES {� - E ,v 'fi`` `fi k SINGLE COMPARTMENT) 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS,100 CFM WITH A SONE RATING OF.9 OR LESS,200 CFM I , i g, 1 o f I i Y [ :- ,tr _•1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE 4. GRAB BAR SATIN FINISH BOBRICK 8-6806 SERIES WITH A SONE RATING OF 1.6 OR LESS. T v a 'ti tg� +�: hj�`�^ --7 2. DOOR AND RELITE FRAMES SHALL BE WESTERN INTEGRATED MATERIALS(WIM),OR APPROVED. SUBMITTAL B. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING MOUNTED fir,, . 3" < ` s�� Y 1 ; I _ REQUIRED PRIOR TO ORDERING MATERIAL.NEW FRAMES TO BE FACTORY FINISH CUSTOM COLOR. 10 44 16 FIRE EXTINGUISHERS EXHAUST FANS,WIRED BY DIVISION 16 AND SWITCHED WITH THE LIGHTS. Rive,. c. C. MULTIPLE FIXTURE RESTROOMS,COMBINATION RESTROOM&SHOWER,AND LOCKER ROOMS TO HAVE ROOFTOP I , 1 ,77 -- 7 � _ P� 3. FIELD VERIFY EXISTING FRAME FINISH PRIOR TO ORDERING NEW FRAMES. ALL NEW FRAMES TO MATCH 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) MOUNTED EXHAUST FAN,FACTORY CURB AND BACKDRAFT DAMPER,WIRED BY DIVISION 16,CONTROLS AS REQUIRED 4£ `� " I AREA OF WORK W It EXISTING BUILDING STANDARD FRAMES. �" BY DESIGN.COOK ACE-D SERIES OR EQUAL. I�� - ' P f Y tf� _ 4. ALL DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 2 00 00 FURNISHINGS NGS D. SPECIALTY ROOMS REQUIRING EXHAUST SHALL MEET THE ABOVE MINIMUM REQUIREMENTS-INDIVIDUAL ROOMS _;' , r' f °,41A:: :. Cs) 1. CONTRACTOR TO CLEAN/REFURBISH EXISTING BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. WITH AN EXHAUST REQUIREMENT GREATER THAN 250 CFM,WILL REQUIRE THE USE OF A ROOFTOP MOUNTED FAN. co 5. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. h I i a j£ iA w` I 24. HVAC TESTING. TO INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. _ I ,,,,,,,,,,,..-,4415- 1, 4,0,A r �� w N 6. ALL HARDWARE SHALL BE INSTALLED WITH A 5 BACKSET. 2. CONTRACTOR �._ A. CON1ROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT AND D `� �''° f oar T E 7. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES,DOOR HARDWARE 21 00 00 FIRE SUPPRESSION SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. i g i I AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN WI STAIN AND FINISH APPLIED(IF B. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH I I I o NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT SHALL 1. ADJUST EXISTING SPRINKLERS BELOW SUSPENDED CEILING PER CODE PER NEW WALL LAYOUT. SPRINKLER HEADS APPROVED PLANS AND SPECIFICATIONS. Co) el C4 APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS PROCESS SHALL BE CENTERED IN 2 X 2 CEILING TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL n - - - - if____ 0 C. A COMPLETE COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH - ,• IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL SAMPLE. HARD CEILING AREAS(GYPSUM BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO PACIRUST. 0 O INSTALLATION. 0 0 8. ALL INTERIOR GLAZING SHALL BE TEMPERED. 25. PROJECT CLOSE OUT DOCUMENTS REQUIRED: I 2. PROVIDE AUTOMATIC FIRE SPRINKLER FLOW INDICATOR SIEMENS'CU-MHU-MCS-W OR EQUAL. SEE PLAN FOR 9. DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE CYLINDER A. AutoCAD FILE SHOWING AS-BUILT INFORMATION. _ _ _ _ _ _ _ _ W ).•'•i LOCATIONS. F) - F.-4 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RILE CAM AND COMPRESSION RING 1 1/8"LENGTH WITH B. ELECTRONIC PDF FILE OF THE AutoCAD FILE ABOVE. -' IJ H MATCH BUILDING STANDARD. AutoCAD FILE ABOVE. HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MA 22 00 00 PLUMBING C. HARD COPY OF Au oC L I � I I � � C. 0 10. TUNE UP EXISTING EXTERIOR MAN DOORS AS NEEDED. D. OPERATIONS MANUALS FOR ALL EQUIPMENT,INCLUDING T-STATS. E. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. f V_ 04 N a' GENERAL RE UIREMENTS 11. PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP Q`-- - - - -i- FINISH FOR AS NEW LOOK. 1. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF RESTROOMS. 26 00 00 ELECTRICAL LOCATE VALVE BEHIND HANDICAP TOILET IN MEN'S RESTROOM. REVISION 12. TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. Ii i 13. TUNE UP EXISTING OVERHEAD DOORS AS NEEDED. 2. WATER HEATER(ELECTRIC)30 GAL AND LARGER 277V LESS THAN 30 GAL 120V. PROVIDE HUB DRAIN AT LOCATION. GENERAL i tH} -- 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC.MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. EXCEPTION OF 1 BE INSTALLED IN TOILET ROOMS CONTAINING TWO(2)OR MORE WATER CLOSETS OR 2 OR MORE `_l � �- r �- 3. FLOOR DRAINS SHALL IN ( HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD ACCEPTED. 09 00 00 FINISHES WATER CLOSETS AND URINALS IN COMBINATION. THE FLOOR SHALL SLOPE TOWARD THE FLOOR DRAIN. 2. PROVIDE LABEL FOR EACH CIRCUIT AT PANEL FOR IDENTIFICATION PURPOSES. N 2. GENERAL 4. FLOOR DRAINS TO BE INSTALLED Wlll�PR A 2 BUILDING PLAN IMER VALVE WITH ISOLATION VALVE. PROVIDE A MIN.OF 18"ACCESS DOOR. 3. ELECTRICAL CONTRACTOR TO PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING CORRESPONDING 3 A -1 NOT TO SCALE N SEAL N WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. BREAKER SWITCH AND PANEL. OT O SCAL 1. CLEA L A D REST ROOM FIXTURES(MULTI OCCUPANCY)PLUMBING -RES 00 ( 1 . - 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 4. CONTRACTOR TO VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESSOR SUITE NUMBER. METER 4 1. TOILET W/FLUSHOMETER=AMERICAN STANDARD AS 2264.015 AT NON ACCESSIBLE STALLS AND 2305.100 AT a. FLOOR COVERINGS AND BASE ACCESSIBLE LOCATIONS. FLUSHOMETER SLOAN FLUSH VALVE 111 IDENTIFICATION NUMBER AND TENANTADDRESS INFORMATION SHALL BE GIVEN TO PACTRUST PRIOR TO TENANTS MOVE- P PLASTIC LAMINATES IN. 5. b. lA C LA S 2. SEALANT AT PLUMBING FIXTURES: C. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN PATH SHOWN ON PLAN EQUAL TO 1-FOOT CANDLE. � �`C Q� 6• d. PAINT COLORS . A. ALL SEALANT SHALL MATCH GROUT COLOR AT TILE SURFACES. 6. FOR EXIT LIGHTS USE RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE HOUSING,WITH CITY T GA O E. � e. TILE,MARBLE,GRANITE,STONE,AND GROUT B. SUBMIT SEALANT COLOR PRIOR TO INSTALLATION FOR ARCHITECT APPROVAL FOR ALL OTHER APPLICATIONS. Occupancy Type 7. f. TOILET PARTITIONS BATTERY BACKUP. Approved 4?ccupancy I.:oad > N -BREAI(R M FIXTURES PI ( Type „ $ PLUMB( G ROOM TO PROVI E 208V/120V POWER Construction T 9 HARDWARE 7. WHERE NEEDE D CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS D Construct yp 8. ' Conditionally Appt-or�ed [ ] � 3. FINISH FLOORING TO BE INSTALLED UNDER ALL NEW CASEWORK. 1. 114"COPPER WATER LINE W/SHUT OFF VALVE FOR COFFEE MAKER AND REFRIGERATOR,SEPARATE LINES IF FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. See Utter to: Follow ( hated Corridor REQUIRED. r Cade Q a. TRANSFORMERS TO BE ENERGY STAR LABELED. Energy gy 09 21 OO GYPSUM BOARD b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. Atta &ed - a 23 00 00 HVAC TM1O° � Accessibility DRAWN BY GENERAL c. ENCLOSEDANDVENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C TEMPERATURE Permit i\Tt��7?uet:, RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS OPERATION. EQUIP WITH 2-1/2 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH 1" GAS METER, PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM SOUND LEVEL SHALL BE NEMA STANDARD TYPE S-12 SCREWS 12"0.C.UNLESS OTHERWISE NOTED. ''' 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. METER WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL ASSEMBLY AND CASE. By.: _ ' N .Date:_A ' "-`J DATE: 3/31/10 IDENTIFICATION NUMBER AND TENANTADDRESS INFORMATION SHALL BE GIVEN TO PAC-RUST PRIOR TO TENANTS 8. FOR FLOOR POWER AND DATA ACCESS IN BUILDINGS WITH ACCESS BELOW FLOOR,USE WIREMOLD RC7 FLUSH POKE- 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN BID/PERMIT SET ; FINISH COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. MOVE-IN. THRU SERIES OR EQUAL. FOR SLAB ON GRADE INSTALLATIONS USE RACO#55111,2 AT EACH LOCATION TO SEPARATE U BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH HVAC -BID PROCEDURE POWER AND DATA. 3. ALL 011-TER GYPSUM OA Y FUTURE TENANT. COAT. PAINT AS INDICATED. 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN PROPER a TELECOMMUNICATION SYSTEM B U „ LARGER. REQUIRED OFFICE AREAS 5 000 SF AND LARGE . MANAGEMENT IS REQ IRE 4. ALL ONE HOUR RATED WALLS HERE APPLICABLE): ONE LAYER 518 TYPE X GYPSUM WALLBOARD,EITHER AT WORKING ORDER. 10. LIGHTING ENERGY MANAGE EN , N HOU TE NU RIGHT ANGLES OR PARALLEL TO FRAMING ON EACH SIDE OF MET A L STUD S SPACED AT 24" O.C. FASTEN WITH TH 2. INVENTORY EXISTING H.VA.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECTA CONDITIONS REPORT OF EACH UNIT 11. OCCUPANCY CONTROL DEVICES SHALL BE LEVITON OR WATT STOP. 1 TYPE S DRYWALL SCREWS 8 O.C.TO VERTICAL EDGES AND 12 O.C.TO TOP AND BOTTOM RUNNERS AND 24" 12. CONTRACTOR SHALL TESTALL LIGHTING CONTROL SYSTEMS TO ENSURE THAT CONTROL DEVICES,COMPONENTS, INTERMEDIATE STUDS. STAGGER ALL VERTICAL AND HORIZONTAL JOINTS 24 O.C.(OR ONE STUD SPACING), 3. LIST TONNAGE OF EACH UNIT. EACH SIDE AND OPPOSITE SIDES. EQUIPMENT AND SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND HVAC-DESIGN PROCEDURE 5. IN FINISHED SPACES PURR-OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH 5/8"GYPSUM BO ARD OVER SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE TRAY OPERATE IN METAL STUDS. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS LISTED ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. BELOW. 13. WHEN REQUIRED IN DIVISION 15,PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. 6. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR GLAZING. OFFICE COPY BUILDING DEPARTMENT USE e` B U IL • �`yi---� if� ter-^l�� i�-"\,\ � �r ��� � \\ f,� _�\ ,/y , ,, • ( i \, , \ /1 . , 1 t i F ' rl � , , , \ zu,) , , ), 'LI / , 1 , 4\ „ X3082 ,� _ � ��/ i �`—- M RTIN W. HANSON 'C ! I I ! �� ('� ! REMOvE N !OGAN CEDARS AND /1 E p__i l r INSTALL NEW LANDSCAPE PLANTS CLACKA AS, OREGON . ____1 , , , , Li(\ /J �,-_ ,i� _ - _ It_:�_.__ J t, y-_ ><a SHELF { 01 OV , s 9 if ; rii,........_ i` --i- — —II— -s- - ,I-- - II- — ALIGN ! ! - I •, ELE l - - _ ELEC PROJECT II 1 ti �1 , 3\ isz �_ _ € �,� , i f„'^:.- 2' .,- '•r"' '4 -ks- `, P- k Fit -- {+ #10210 OFFICE - F- I I I CIRC. E t ROOM i i ,.. f _ ROOM F - E) (E)11.9.1.13] ' 106 E 5 I NEW CONC.WA .-------I ' . K 1 I:< , :., ;ia , Ill ff:._,--_,-„,,b9- I..,:::3,,. ' MIMI '''' - ''' �t t clo l Cid 1 [I1ii M15 I, F ', ! ENO :E I _ ! 1----. --�f , �•�-: ;�.:�- Fes.-; -��; .. - - - -- _• �� I I �1 103 $ 7 � `...•� -a�` :�TT� ! _�._ - s - �� " 11 as -, �. L � : �Y a iii 1 E it_. --- -' I�_ -- _ I I I 111rC,1 f �� - - - -' S i !CONFEREN E ; 1 I F;- - (( t f •105 - ►. 1 I- I IN \ - n ;, I I I 'DTI - '. ..,...,„.._, . , 1-,,,1 , + a I; , € i s r � en K /) — ,a : �k , a _ I 1NAREHOUS I j��� .. ;` °I 1• l e 2 J , ! F - 4 T rat i ,_1 4, i 3 i X01 _ :i` ;' 114 t e, t t a 3 tt ` I �.f. F t" I I �) S 1 {J.,,;.,--:,,::::„ �'• i I _ j III 1 i V I 1 ! ! r° ' .Ch' I ' • I I j ! p N g - I q 1\1 ii F 4 g a i i t. ff'- -- __,. ?r... -, °:'$:J ,_ ,_. ' i 6 OFFICE "- I ti __m4 �:l 1 p 104 - - - -T- -_ - -• - - - . WOMEN a 0 MEN !hI I I cn . :gym A- _ 1 I i !�: ! ill OI 108 1091 I- ! v: 1 1 1 i ='{ v,- ! E „,,_ U I > I , W — ii , \t. 1 ! t A�AAAAAAAAi M�Ar /•�/-1••)GP (E)LP I -- ;- - — ; '. ! ' 11, ''' I _ _ _ $3 ! ! Cn'� M O ,z 3 Ii ! , I• ti .,� -.sy. -,.._.; .-. _ - ,#�;;'.a` - ,.41`71;;;'- - `'\.a r°`r t�`_ ry CIRC � _ In 141 ` ,I---- I '' i, - : 1 107( W- w •K-�a' '4", �. • II;•.." ._ -.- ,._.� 'i cy 1 - v+ `./��iii{ i — W -_! IEi:: T ; , -1_„,_,,--,_,,,,„., h _ ri 3 E ill i.-,7:e'ii , — : j' OFFICE TEULAN BREAK _'a' - - - - - - - - - - - - -, ,- - - -- - - - - ' - - � - - -F� - - — - - - - - - - - - D-- � � - j _ _ �� - - - - - - -, - � - - ,>‹,..,t, I i \ C 11/� [102I !I - !i ' 111 1 i0 -_II _ .1 I1 T .�•. , ..-- -_I.. II !I---- __-!-_ _.-__... I', ! - T, c - ! T {`'R. 1'=_r' , _~<'^'o •,��r:!`r { tE)LP i # -.- -; I �' I : _. I { ` r t • f f - -1. - 1 I I OPEN OFFICE I ,. E � _ -II �_ _._ . —_ _ x_ !•_ jj _ _ IC _ri Ij I It , I ,..1, z fir''-:ate+ ,r�" r`` .,. -,"-- 04,'(.:.��..k. `1„ -i- ` �•'' - _ `'',1- t``a'" _ .� I k �;r.�i I 9 -, - i t ( I s 1 0 .i I. ! .,_ __qq _- -_- -` r--.- __-_. _'- _ -_ �"-- 1 116. J F'J -�":.� - L• _ - j - 1 j L , o a • T. •I it ._..-. _ ., - _t I II ' : ' I '• I { ':. fit- __..1. -___.-_. fr i ■ _ , v t , 1, • : I Ir r• .. l I OPEN OFFICE ! 1.31- lie ,� ! „,R” alalanr . a FA tv I, 101 1 1 ::: • -- I - - p I e - I i � y J s - ' �S i L E „'. 1 ..•.''`�[ �� - i" „ I� I I � I t - f' s Z L i --- - -; -; �".. i{ ; tea , 1 g II I li 9 1,,,, 1 1, , . .. ® g v� :; ` a 0 I . . f �s# ,I- __ , ---11- } ; 0 _ ,F : t;,.:- i t`,. ,-. .,_- _ it , 1 T21 , I �j' £`t �S'..- f -�`'*.. I I ( D L- - _ _ _ ._ __ _ .. 3 �a `°;e' \ 'k 1 S dE • }I Lt.____±_.___ _ _ _ - .- - i j a - - © 1 , 3 *I i i , . _ . , . 5,418 SF OFFICE ! ! ! ! ! 1,280 SF WAREHOUSE ! I ! ' ! ! 6,698 SF TOTAL ED N REFLECTED CEILING PLAN N POWER PLAN WORK SCOPE NOTES: 1 PARTITION AND POW 2 A-2 SCALE 1/8"=1'-0" 0 Remove existing partition as shown. A-2 SCALE 1/8"-1'-0" CD 0 2 Building standard office partition(insulate as indicated). 3 Building standard restroom partition w/insulation. INDICATES COMMON PATH OF TRAVEL REQUIREING EMERGENCY C� .- LIGHTING EQUAL TO 1-FOOT CANDLE.• 4 4'x 6'wide relite-leave 8"wall between jamb Herculite door and relite for light switch DOORSCIIEDtJILE 5a Building standard door/frame(relocate where _ ... _. . .. _. - . possible). DOOR DATA FRAME DATA HARDWARE . - 0 Relocated Herculite door/glazing system. Build In Fire Rating Mark Door Size Thk Core Veneer Finish Hand Type Frame Depth Hardware Manufacturer Finish Function Remarks partition to match existing to complete wall. pq -- 7 Extend existing Men's rest room to north wall of • 0 I A I 8 A A 1 3 3 -0 x 7 -0 13/ SC BIRCH CHERRY Right WIM 4 3/4 LEVER LATCk SAL SERIES) SCHLAGE 6,05 PCL151�ED PASS AL105 I. warehouse,including ceiling,plumbing wall and floor V Z', 100 31-0' x 11-0' 1 3/4" SC PINCH CHERRY Left 0 WIM 4 3/4° LEVER LATCH (AL SERIES) SCHLAGE 4605 POLISHED BRASS AL108 I. finish. Provide and install two WC's with toilet W V 112 3'-0" x 81-0" 1 3/40 SC BIRCH CHERRY Left 0 WIM 4 1/S" LEVER LATCH (AL SERIES) SCHLAGE "605 POLISHED BRASS ALIOS 2_ partitions to match existing. Rough-in and cap at 116 3'-0' x S'-S' 13/4' 5C BIRCH CHERRY Left ! WIM 4 1/8" LEVER LATCH (AL SERIES) SCHLAGE 4605 POLISHED BRASS AL10S I. floor-two additional WC's. E-4 N Remarks: ® Cut and remove to tile joint line to extend full tiles N immus 12" into rest room extension. 1. Cut-in full relite in new/existing relocated door-wood stops to match door,stiles=12 bottom, 8"top, 6"sides. 0 Tenant systems furniture. .. 0 standard sidelite(3'w.x 8 10' tall). O Building ( ) u. • • 2. 6 x 36"relite this door. Q 8 f� ABBREVIATIONS V - L O S �, Note-latch sets available from Landlord stock,contact Denni Pagni FINISH MATERIALS (MARINE) (BLUE) SUBMITTED TO PACTRUST PRIOR TO INSTALLATION. BRK BRICK PAVERS V H ALL FINISHES MUST BE BMI U o fx CP-# CUT PILE CARPET Q AM 'it O C FINISH CARPET CUT PILE: CR CHAIR RAIL 0 ci) _... CP PATCRAFT 10200-WINDSWEPT ENCORE-30, 00583 FLINT OVER PAD E EXISTING � _•• ETR EXTEND TO ROOF CONSTRUCTION LEGEND WALLS CLG. CARPET LOOP PILE: FWC FABRIC WALL COVERING REVISION RM# NAME FLR BASE NORTH EAST SOUTH WEST CEILING HT REMARKS LP PATCRAFT 10148-HEADLINES II, 48402 ESCAPE FROM ALCATRAZ, DIRECT GLUE GT GROUT CONTACT FOR PACTRUST PRICING&ORDERING INFO: IVY O'BRIEN 503-754-6826 HM HOLLOW METAL 1 _I EXISTING TO REMAIN -- 1. 101 OPEN OFFICE LP/WOC 4 RF PGWb PGWB E-PGW3 E-WW PGWP E-SAT 9'-O' PGWB PAINTED GYPSUM WALL BOARD c D EXISTING TO BE REMOVED I 103 OPEN OFFICE LP 4' RF E-U JJ-PGWB PGWB E-PGWP E-SAT 9'-0' -- WALK-OFF CARPET PL-# PLASTIC LAMINATE - n WOC VAN DIJK CONTRACT PROTECT SUPER#25 PLW PLASTIC LAMINATE WAINSCOT NEW STANDARD WALL 2. A 105 CONFERENCE NEE GP 4 RF E PGUJB PGWB E-PGWB E-WW PGWk3 E-SAT 9-0 POT PORCELAIN II ILE n r+ , ° 3__ PORCELAINTILE AND GROUT NEW STANDARD WALL WITH INS,106 OFFICE CP 4 RF E UJUJ E PGWB E/N-PGWB E-WW E SAT 9-0 POILE WAINSCOT POT-1 FLOOR-FLORIDA TILE,LAS OLAS LS5507 SEA OATS 19"X 19" ®® 101 CIRC. LP 4 RF PGWB PGWB PGWB PGWB E-SAT 9'-0" -- PT-# PAINT 8 4 BASE-FLORIDA TILE, LAS OLAS LS5507 SEA OATS 19"X 19"-CUT TO 6"TALL, FACTORY EDGE UP a NEW STANDARD WALL WITH INS.TO 12"ABOVE CEILING GRID • 109 MEN POT POT POTIU-PGWB PGWB PGWB POTW-PGWB WBC 9'-0' -- POT-2 WAINSCOT-FLORIDA TILE, LAS OLAS LS507W SEA OATS 13 X 13" -FACTORY EDGE UP/OUT RC RUBBER BASE COVED 112 OPEN OFFICE LP 4' RF PGWB E-PGWB E-PGW ATICRE B BOLUS E-SAT 9'-0n -- GT-2 LTE 39 MUSHROOM(NON SANDED) RF RUBBER BASE FLAT S. 113 CI C. WOO 4" RF E-PGWB PGWB PGWB E-PGWB E-SAT 9'-0' -- CONTACT FOR PACTRUST PRICING&ORDERING INFO: BOBBY THOMPSON 503-226-6077 SAT SUSPENDED ACOUSTICAL TILE • #D DUPLEX RECEPTACLE ® ELECTRICAL PANEL R SC SEALED CONCRETE 6. - - ;It FOURPLEX RECEPTACLE Q POWER J-BOX IN WALL 1 CEILING FOR TENANT FURNfTURE A I A •• T __ SV SHEE VINYL 114 WAREHOUSE 5C 4 RC E-PGUJB E-PGWB PC�UJB PGWB ETR 9 0 VINYL COMPOSITION TILE 7. VCT ARMSTRONG STANDARD EXCELON 51908 PEWTER, 12"x 12"x 1/8" VCT VINYL COMPOSITION TILE WBC WALL BOARD CEILING 4D DEDICATED OUTLET ® FLUSH MOUNT FLOOR MONUMENT W/POWER AND DATA 8. J G WALL CORNER GUARD I�•, BASE WC O { EXISTING ELECTRICAL TO REMAIN FIRE EXTINGUISHER IN RECESSED CAB. RF JOHNSONITE 4" FLAT RUBBER BASE,63 BURNT UMBER AT ALL CARPET AREAS. WD WOOD RC JOHNSONITE 4"COVE RUBBER BASE,63 BURNT UMBER AT ALL HARD SURFACES. WOC WALK OFF CARPET @D1 FLOOR MONUMENT W/SERVICES SHOWN O FIRE EXTINGUISHER-SURFACE MOUNTED , WW WINDOW WALL DRAWN BY: PAINT: s SPECIAL OUTLET ® THERMOSTAT PT-1 MILLER 4480 PREMIUM SATIN 0210 HIDDEN COVE, SATIN LATEX PT-2 MILLER 4480 PREMIUM SATIN 0542 CAPTAIN NEMO, SATIN LATEX (ACCENT COLOR) 1 TEUDATA MUD RING WITH PULL STRING - DATE:E: 3/31/10 CONTACT FOR PACTRUST PRICING&ORDERING INFO:AMY TACKE 503-348-3307 . BID/PERMIT SET >< 2 X 4 FLUOR.FIXTURE ® EXHAUST FAN .:. , LAMINATE: PARABOLIC LENSE PL-1 WILSONART D92-60 DOVE GREY,AT ALL FACES. • SPRINKLER HEAD 4889-38 PEARL SOAPSTONE, COUNTER, B.S.AND SELF-EDGE. SE IM 2 X 4 FLUOR.FIXTURE PL-2 WILSONART , PL-3 WILSONART 1531-60 LIGHT BEIGE, TOILET PARTITIONS. FMCS S PARABOLIC LENSE/STEADY BURN BALLIST iiii EXIT SIGN(LED RED) CONTACT TECH SERVICES: 800-433-3222 NEW 1 RELOCATED GtQcx HORN/STROBE FIRE ALARM(WALL MOUNT) • FLUOR.FIXTURE LOCATION DOORS, HARDWARE AND FRAMES O s 0,N) HORN/STROBE FIRE ALARM(CEILING MOUNT) HARDWARE 605 POLISHED BRASS 8 RECESSED COMPACT FLUORESCENT LIGHT(TYP-) ' A. 2 FRAMES PAC RED ' X 0 SMOKE DETECTOR SUPPLY DIFFUSER CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS. XRETURN DUCT . &OD 4/PC. ) . #3082 .. 20 GA 3 5/8'METAL STUD BRACING MARTIN W. HANSON ' -S TO ROOF STRUCTURE AT 10'-0' OC _ WHERE REQUIRED /� /' y Roos DECK � � .,,----,.� ��CLAC�, AS, OREGON,. OR BEAM ; �� EXISTING SUSPENDED CEILING % ) ‘`-e RACO F5-4B RECESSED 0-' REVEAL HEADER \` :� OF /->/ , �\ r PROJECT 1 1 1 / / / SUSPENDED CLG ASSEMBLY a,_9, OJEC # 02 0 3-5/8'MIL.STUDS 24' c.c. /� �1 L 14 / 7 5/8'GYP.BRO.BOTH SIDES _ L45? \ --- ----} CENTERLINE OF STUD �„J� _ , --.../ \ I ± ra-�-CI Q, 1� /171 20 GA 3 5/8' METAL STUD BRACING I I I [1°� j______,V TO ROOF STRUCTURE AT 10'-0" R400 TOP OC W/ (2)*S SHEET METAL TRACK w/ RACQ SCREWS A EACH END. BRACING — ' i • c..) TD BE PRO`IIDED WI-IERE DISTANCE w BLACK REVEAL,7YP EA SIDE BETWEEN PERPENDICULAR INTERSEGTINC -'-10 _ t 4' RUBBER BASE-TYP_ WALLS O1R HORIZONTAL �aRAC(NCx ; ,4-3 . PTOTICEHRIVIZ)C°,,E1-1\111-ATIC190TIRS)FLOOR WITH I _ AT !2'O.C. BETWEEN WALLS EXCEEDS 12'-0° OC i I 1 1=1NISH F oo �_ ., MITER TILE 1 :I L R • �c�f ►� / \ AT CORNERS o `� I • 4 1/8' ��- TYP. VI ;t 04 \TYPICAL WALL SECTION (-5-- . WALL BRACING DETAIL .� Ij. •. i 4\ V • N_ I A-3 SCALE 1" = 1 -0" 3 SCALE 3" = 1'-0' I • N i _ 1 i i V „--- / O r4 °`r' ��o 4 pci: - `'?` . 1 3 i_ , 14314' F� c!� cv cv 20 GA 3 5/8'METAL STUD BRACING ( - o TO ROOF STRUCTURE AT 10'-0' OC - -- - - -t 3 1-1 - - �I�I - in pm ��..� WHERE REQUIRED r -1 ts -" _ , START FULL crl O Z*>< littallatilla R-Il BATT INSULATION 4' CENTERED OVER WALL . , 2' TILE HERE TYPICAL STUD 1 _=_.--_ r .-._- EXISTING SUSPENDED CEILING i� RACO "F5-4B RECESSED �� REVEAL HEADER / } 1-< 3-1/2' BATT INSUL. \ TYPICAL TRACK I 100110,00100•� INSTALL STUDS WITH SAME \ �! Pil ' DIMENSION (10° MIN.)FOR -� 3-5/8 MTL.STUDS a 24 O.C_ cc) 5/8'GYP.BRO.BOTH SIDES BRIDGING ALIGNMENT LAI ,..,t) 0 61 CENTER LINE OF STUD I f - fa. a Ii.al ii in 0 E-4 a i'VJJ '0/ a POWDER DRIVEN ANCHORS AT 12" O.G. t '! r (dl MEN 47 CO J 1 ATTACH BOTTOM TRACK 70 FLOOR WITH PER STUD FLANGE 108 ) 109 I I POWDER DRIVEN ANCHORS AT I2 O.C. �- n I ;�__ A TANA FINISH FLOOR did 4 1/8' G 4 Abi WALL SECTION W/ SOUND INSUL. 6 WALL BASE DETAIL EL A-3 SCALE 1"= 1'-0" A-3 SCALE 3" = 1'-0" AT CUT BASE (NON-WAINSCOT WALLS)-ALIGN RAGO HEAD JOINTING IN BASE WITH FLOOR TILE JOINTS . 5/8' PLYWOOD DECK WITH --- �-- -FACTORY EDGE UP (COLOR MATCH EDGES). 10' MAX SPAN SHEET METAL SCREWS OVER . AREA INDICATED ON PLAN `� 0 ___ _max__ `' —�ri-i 8005250-54 METAL STUDS AT I 16' O.C.,ALIGN WITH WALL 5TUD5 I 1 nf�o' �O' ESTOOM PLAN N F ED es. INSULATION METAL CEILING STUD LOAD CHART ' 2'-0' u 1 I * LITE:KIT WHERE SPECIFIED 9 Will I _ mg �:.:.' __.: ' MAX.SPAN 10' "- '_ " I A-3 SCALE 1/4 -1 0 •S MAX.SPACING I6 w itMAX.POINT LOAD 315 LB/STUD 5/8'GYP.BRD. 4� j 41, SUSPENDED CEILING I B 36225131-33 METAL STUDS AT IV OC. z M 0 - a' u , � d � ADDITIONAL SWITGN o w w GANG LOCATION z W 0 5' z • E.., /8 TYP LIAR I , 1- V ici)GYP.BRO. X5/8'GYP.BRD. - 1- T W i \ at U CENTER LINE OF STUD g �`� 3-1/2'F.G. INSULATION ELECTRICAL u ul n Q� [tV ►��� 4' RUBBER BASE-TIP. w OUTLET yj 3 O U b MIN.BASE '�� g SEE FINISH SCHEDULE '`� ATTACH BOTTOM TRACK TO ( tk & - • FLOOR WITH POWDER DRIVEN O w O FOR 1 +- RMATER AL .�� �- o = " ANGHO S AT 12' '- • R A O C. I � FINISH FLOOR �� UNDERCUT DOOR A - @ O V _ a� -co 0 0 0 .- FINISH FLOOR-TOP OF SLAB 0 REQUIRED TO CLEA c� m � Sl m FLOOR FINISH w REST ROOM 51D OFFICE SIDE t U 0 • H 3 REST ROOM WALL SECTION Alk MOUNTING HEIGHTS -, o O A-3 SCALE 1" = 1'-0°► A-3 w SCALE 1/2"= 1'-0" REVISION 1. 2. 3. 1 ®- - - -4_ _ - - - 4 ° 1 -3 I I 5. 4 to - - I L. i 1 M 4 > 6. w I a l l- a 7. r SOAP PAPER TOWEL SAN.NAP. PAPER TOWED RECESSED FACTORY EDGE UP FACTORY EDGE UP 8. DISPENSER DISPENSER DISPENSER DISPENSER/ TOWEL ! I 1 ( ( I I � ' °' O T W I N 5C OT DISPENSER ! I , P WAINS OT f I I DRAWN BY: 1 I 1 ! _ { I I r _ _ I_ ( I I 1 I i I [----3 I ' I Cl � d I 1 1 - - _ , o i I ■, DATE. 3/31 10 __D — , 1- - �. .. 1 - I ,T- I - 1 - _I :r �3ID/PERMIT SET Ilr _Zit* FIl 1 3 3 } co 1=' I 1 0 __I 1 1 ..:, ED caE3,--1 tio 2 u_ ":46 g -,- cil !T O 0 1 1-- ) 'r MO 1 _ I _ - I 1 I I 1 I A 3 SEAT COVER TOIL.PAPER/ GRAB BAR MIRROR - - I , 1 , ' 1 t ' I I DISPENSER SEAT COV.DISP./ 1'-6' 2'-11' 1 21-9"SAN.NAP. - WEST SOUTH S DISPOSAL i a'-II 114 51-3° -- not t used _- TOILET ROOM ACC. - MOUNTING HEIGHTS RESTROOM ELEVATIONS (109 /115 ICE 4 8 10 A-3 SCALE 1/4"=1'-0" A-3 SCALE: 1/4"= 1'-0" A-3 SCALE 1/2„-1'-0►' . . . . .