Loading...
Plans • O9OOO97 : 2225 'TE L DEROSIA C I ,.� v 'I RTLAND, OREGON„ . TENANT IMPROVEMENT FOR r' 1 3 SPEC SPACE VACANCY UPGRADES ? p� O • F 16588&16596 S.W. 72ND AVENUE TIGARD OR 97224 PROJECT #09200 PROJECT NARATIVE: THIS PROJECT THIS PROJECT IS A TENANT IMPROVEMENT REMODEL TO NTFRSTaT UPDATE VACANCY SPACE IN ORDER TO ATTRACT A NEW TENANT U 5 /\ REVISION 3 RECONFIGURED AND COMBINED THE SPACES IN 16592 AND 16596 TO w CREATE A SINGLE TENANT SPACE. Q 4 .4.4 8 1 lr11/r Ilrlllrrlll 111 1r r lllr (123) I , , T illi■ L /1 WORK INCLUDED BUT PERFORMED UNDER SEPARATE PERMIT (121 i ,�,'(122) F Q o (124 1''- """ PLUMBING 0 j l� I i 1 I l I _ N , ' ee* ''' HEATING, VENTILATION AND AIR CONDITIONING 0 (.9% cS� "'�._ OSWEGO FIRE SPRINKLERS CC 2 400 - ' 3 ' ® = EXIT#290 ELECTRICAL INCLUDING LOW VOLTAGE(PHONE &DATA) W G •` 018) 110 (125) ,c, ; ` AIL-1-1 tti - (116) ( ) _ - 0 d' r CV Trr !!5!!!!!!!!!!!!!! (126 �°o _ it _ _ - DRAWING INDEX 0 17 N �` (112 . _ x, (108) = >]= _ O CO S� - __ - (113) r - A 0 MAPS, PROJECT INFORMATION W {117 Sul — _. –�, :. ..., . .. A-1 DEMOLITION - FLOOR PLAN U) d'd'9 CV N �_ �� �, ii A-2 DEMOLITION - REFLECTED CEILING PLAN (127)- 1 (105) REFLECTED CEIG PLAN - NEW 12( , - (114} �1111� �11 IIIIII1fl 1111111111iIIVllllllilil111111 11 �� J [lIIHiiiiili/iii( A-6 SPECIFICATIONS , , „ SW 72nd AVENUE 1i iii \` BUILDING INFORMATION BUILDING OWNER: PACIFIC REALTY ASSOCIATES L.P. LIU , 15350 SW SEQUOIA PKWY#300 0 II PORTLAND, ORE 97224 ill (503) 624-6300 (PHONE) d' CV 0 , 1 - (503) 624-7755(FAX) cc T SITE PLAN VICINITY MAP /� o� " = 250' - " OREGON BUSINESS PARK 1 f- SCALE 1 250 0 BLDG. #: O il A-0 MIFF Q_ ....-- O. BLDG- 11 (PTR #124) TYPE II-B CONST. TYPE.. '- 16580 16588 16596 16598 D o 3 STORIES: 1 Z / NO WORK / / NO WORK . a_ J - r ALLOWABLE AREA(BASE): B 1.3,000 sf — .=;►♦�`i OM P-♦�`.�♦�Mil NOV -♦. ♦. (Table 503) S1 -; ::sf::::::::: ■�1♦♦♦�♦�__- ►♦/►♦� _ -:-:♦♦'*♦4 S2- sf. 4:::::::::-. B 0 1 ::::::-;::::::.:::::::.:::::::::::::. .., -:::::-..::-:B:: :::: ■-1►♦♦♦,.7_,....:.... ♦♦.♦4 ►♦. ♦♦ ACTUAL BUILDING AREA 39.3 sf EXTERIOR ENTRIES 4 , :.. _ ■�■1 ♦♦♦♦♦♦,_:::: j►♦♦ ♦♦ -:=::.:: ::_-,,∎w , ::-::::-_-_-_: 2,1913 sf OFFICE ( B) ■�1 ♦♦♦,-_:__,♦♦.♦ ,` ♦♦'v,v, ►�.� 3,901 sf AUTO REPAIR GARAGE (S 1 ) I WAREHOUSE S-2 Cas) , 1071 sfW .u.�I►♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦�'♦♦♦♦ 17,201.3 sf TOTAL ■■•�1 ►♦♦ ♦♦♦ 4 'B', � E E < , ■■sl THIS 13 A ONE STORY BUILDING WITH S-1 AND S-2 1 ► E ■■■�I►♦♦♦♦♦♦♦♦ ♦♦♦♦♦♦♦� ♦♦♦♦ OCCUPANCIES, FRONTAGE ON THREE SIDES EXCEEDS 60', ♦♦♦♦♦ ♦ ♦p:1rv.v� ♦ IS 55 S 1 �'♦♦ THE FOURTH SIDE ■■■�■1► FRONTAGE ON E 1►♦ ♦♦♦�♦ BUILDI NG HAS AN AUTOMATIC SPRINKLER SYSTEM THROUGHOUT 4■ 4 Prri‘4P4 W H!—I♦♦♦♦♦♦♦♦'►♦♦ ♦♦♦♦4►♦♦♦' NON-SEPARATED USES: BUILDING IS A MIXED OCCUPANCY, NON-SEPARATED USES 0 ■■■�1 ► (302.3.1) 111 1 ♦ _ ►_♦_♦_♦_♦_♦v♦_♦_♦_►_♦_♦_♦_., _►♦ .► IJ_I OCCUPANT LOAD: 16588 Q N' (TABLE 1004.1.2) B = 359 sf/100 = 4 IV _ S2 = 4,560sf/500 = 9 Z TOTAL OCC LOAD = 13 - 1 EXIT REQIRED (TABLE 1019.2) Y N. 2 0c OCCUPANCY GROUP P PLAN occuP c G o 11 = - 11 16596 04.. O Z_ A-0 SCALE 1/64 = 1 0 B = 601 sf/100 = 7 ° (� S2 = 4,201 sf/500 = 9 U) I`- W LO 0) TOTAL OCC LOAD = 16 - 1 EXIT REQIRED (TABLE 1019.2) LLI Z ,....(CI aC 01. D 0) - ' N 03 0 0 ® z C4 PLUMBING FIXT REQ'D: 16588 - (1)WC& (1) LAV W 0 '7 (2902.3 EXCEPTIONS) 16596 - (2)WC&(2) LAV V W C CE c0 0 VI O 7– CL MY OF TIGARD REVISIONS Approved TENANT I N FORMATION � i*m ,¢ *e .. TENANT: BOTH SPACES ARE SPEC SPACES - NO CURRENT TENANT Se Letter to Follow..rittotti.gvos, iv w It I 1 . Att * •. Ik * t* - Permit Miler .. �.. A - 2' - - Addre .- 3. 06 16 2009 � 1. By. - _ �, Date. ./ 4 5. 04-C 6. *twang Lea4 • IsErtnatederans il( DRAWN BY E i ALD DATE: 5/19/2009 Ic PERMIT SET OFFICE COPY I C"4)‘1 4Yip 4'Pit 1. • #2225 ARM L DEROSIA CI) DEMO - KEY NOTES THIS SHEET ` - : 3PORTLAND, OREGON, 0 REMOVE CARPET&ADHESIVE 1 ilZ) r --- 0 REMOVE VCT&ADHESIVE OF 0 o3 REMOVE VINYL FLOORING&ADHESIVE PROJECT #09200 R I I • _---e-- ---% // 4 REMOVE PLUMBING FIXTURE(S)AND CAP LINES ..__ CD 5 REMOVE WALLS) 0 O REMOVE RELIGHTS 6 O C . �� . r I = C I I -o I 1 . I O , A 1 I i ili I REMOVE DOOR(S)-REUSE 3070 DOORS ONLY® II 5 7 � ) w O O (IF SALVAGABLE)( ) Q I ....m.,.., It •I, u 11 V-___ I 17 16 18 I 16 I e I ® REMOVE CABINET(S) O O O 0 o 1 0 C9% I ci: 1 O O REMOVE STOREFRONT Q I I I I W ,J-, 10 REMOVE STEEL STAIR&AWNING 0 a d = /�/ I-` O 5 (i) , 1 N 0 II �� I O I �� Ii 1 11 REMOVE PLYWOOD MOUNTING BOARD J Q f-----------'1- 1 P1-1 ,r 1Ô®\ /r 3 3 12 REMOVE SURFACE MOUNTED CONDUITS AND BOXES 4 O I rr___ I , 7 I o 1 _ I 5 I II �. r 5 0 0,, C(c. r O �_, �_i 13 REMOVE SURFACE MOUNTED PIPES AND EQUIP (O I I U 1._-_-_-___11 O � - T �� r- .e� I r �r I Q �C'0 I r - C 1 r ' l ,-� ED 1 I C J O I / I-r- '-` I i - I I 5 I I I 14 REMOVE ALL ELECTRICAL,COMPUTER AND H 0 0 I , I � 1 v o O 10 Lo 8 I li u /_ TELEPHONE BOXES FROM DEMISING WALLS CC c 1 8 O I �0II 3 0 7 3 7 �� _ O O (UNLESS INDICATED TO REMAIN) O�-_ Q 1---CL atXi -_ 1 L o I I `J O\`� I 0 C -__J (1) _ J--- iiO r 12 15 REMOVE CARD READER I / 5 ( r - I i O •o 5 I j 4 I 16 REMOVE MINI-BLINDS I {� i 1 I _ O O I 0 II I O L 0 II J1 �I L 7 1 ---J 5 _J 17 (E)MINI-BLINDS TO REMAIN I o I ;.ED 18 E EPDXY FLOOR TO REMAIN 5 2 1 O O O O O 1 @I:: T I ,1' I Cr U , 1 ai. .i. CC a 0 ti ,:,, I I 5 I GENERAL NOTES T O I; EXISTI 1. TENANT B _ EX1ST1. � ENANT � u I0\� ; co - —Oc - D SPACE - - - -o--- - - - - - - - - - - J �_� - - --QCCUP E-n SP GE-- - 'Q H- r , �� 1. REMOVE ALL DATA CABLES LEFT BY PREVIOUS (5 NO WV" 1 gy 5 I L_ F=JJ 12 ' S I NO W K TENANTS. LEAVE PULL STRINGS. z 3 O 5 l�, 7 1 1 7 r O O 1 �► OI I 5 O I 1 o I I ,/ O �-. --� ,,����► ',!, 2. WALL TEXTURE: SOME OF THE(E)WALLS ARE 5 li 5 / 7 01 TEXTURED. THE TEXTURE IS TO REMAIN. NEW W itt r 3-1 tc a 0 r r A O 1► WALLS WILL BE SMOOTH FINISH. ILL O ,_-__-_ --0 7 k '' 5 O 1 O 5 I !► I I O z 4 (i) ,EII:: 1, I I 1' I I 0 ® 0 $1 I I� I ED I cii: ► �� 12 ALTERNATE # 1 : ,Q1 5 O n O i 0 ED I 14 ' O O PROVIDE ALTERNATE BID TO DIAMOND GRIND THE o 1i' WAREHOUSE FLOORS TO REMOVE THE MASTIC LIU o �_ `�' S �� 7 V DOWN TO THE CONCRETE. AFTER GRINDING,SEAL 0 I I 14 L O O I I O Lv � � � THE FLOOR WITH AN ACRLYIC SEALER.___, O18 �� �► COMMERCIAL FLOORING REMOVAL IJi I I O b I + Q O1 r 21950 S.LANCE CT. 0 h 5 6 BEAVERCREEK OR 97004 ._ 0 J� :iii: II N r (503)632-2246 Y N I I I ED ,' 1 �G= _� I r O CLYDE FREED Q c E-_—_, 0�,� Cn CO N I I l0i/r I I W 1 0■ r , O 5 U) 0 I r I I m 0 17 ® ) ® ®J Q z (0 Z O O r, w V Q CA) - - i I I I II 1 I I W 0 QO P t,,,,TT-r r r-r- � II co 0 1 1 1 1 1 1 II O a „ „ „ , ® 7 BAYS AT 24'-7'= 172'-1' REVISIONS,--- 8 6 5 4 3 C2) (1) 1 . A 2. A 3. A 06-16-2009 I V 4. 1 DEMOLITION - FLOO R PLAN 5. 6. Al SCALE 1/8 = 1' - 0" • DRAWN BY: ALD DATE: 5/19/2009 PERMIT SET swans I - CS.W.i .° 4—- 1 #2225 ARTE S L DEROSIA C1 CEILING DEMO - KEY NOTES THIS SHEET ) - y • ..$RTLAND, OREGON,11 43. . (1) REMOVE CEILING GRID,TILES, LIGHT FIXTURES,DIFFUSERS,ETC. ,eit 31 REMOVE LIGHT FIXTURE OF � 0 32 REMOVE CEILING GRID IN VESTIBULE PROJECT #09200 ® / \2 „, 0 16582 411 -- 16580 0 16586 16588 16592 16596 16598 Q C - - u I, , ---,I I I . -- - -- -- -� ' I ' - - !_ __ __ _/` �- T--r , • I I I I II 1 I I I i I I i I 1 1 1 1 I 1 111 I I I I I 1 ii 1 1__I' �__ ----J- I I I I I I I 1 i1 11 11 --1- _ 1 I 1 "ri' '. k=1i 1 _ T I I r u ' nI 1 I n n 1 I II I I+ + 1 - 1 I -I---- --1-- I 1 II • � r--I I I I- I• T I I �I I I � � I I • I I I i 1 I I I I _ __ _ I I + I \ I1 _ I I , \ \ L_ I 1 \ IF �I \ I I II \ I I \ I 1 .1 r I�--, --i 7�--, --1 r- �-,I --�---�---1--�I c- -1 � � I cc \ II I 1NI I II III\ II I I \IIgIII \1 1 1 II \ I I \ I II\ I I\ I I\ II • I I\ I I\ I I\ I I I I \\ 1r 1 I I\\ 1 �1 \ II I 1--- L-�'�-�1L-�__- 1 L I II L �__ L-� I 1 II \ I 1 \ I I I \ II__�J I \ I 1 \ I 1 \ I W I I I 1--}-- — 1— 11 \ I 1 \ I I \ I� III I \ I I \ I I \ I + I \III 11 1 I\I I • 11 \q I II \ I \I I \III II I \I I \I I \I _ I _ CI I _ _IJ-I_- 1 I --1-- --1- I 1 I --I- , I L-� _ L—� _ L_JNIL_-I L-- — ----rt— ® ��.,IIIG �1 /.fL1 I �� I 1L �I + (. I I I 3 0 I I—-I -1-- +-- i i-- r L F L 1 i I ,-1_ I o I ---I II II N I I 1 1 I I r I _ I I I I ��A I t--(t-N-1 L- L �'; I I I - -- _ 1 ei II - 1+ I I • I I I I I I\ II • 11\ I I I El I\ -- I 1 1 I I 1 1 I) I I I I I 1 O~ 0 LO _ I \ III ll \ _ _ --,- T-r- II I 1 r L J _ 0 LO I - I -I T =-a.r r O _ I I . I I I\ I I I I Il I\ I F_� _ _ r \ \ � � -1 1 _ V J \ II \ I 1 � I I I 1 I I \ i I I n I I I \ I I I I \ ! \ I \ I I \ I (� I I \I I G' I II _ I~ I I n I - - _�- L-y1�_ =y I - I\ I I - I \ I I \ 11n I I I I I \/I I '� -- t I � J I I I I 1 1 \ I \ I I I I I \ I I \ I � W 0 1 \I ..-0. \1 1.1-1- \I - I Cn1 II-T---- ICI- lc --1_ I • \ it I I I \II II \I I �'� I I I I i I I - \ ) I II,, - L_-' IL_�I—___ w - I- y--� --I-- Lk- --r - I r z � �-i11- ,-_- - I \1 - ( 1 ,-- 0 CV CV I \ I I \ 1 I i I �I I I II I II 11,L_, I �_ _ I. I l• \_� I I I I I I ( = I L_ I1--� - • • +\ I I CO 0 L _ _ _u _ - J - Z I I I '-- I --1 �- - -- I \ I rr -r � _�--C-J�-k--1----T-� I r`._::- I II II I I -- , -- -- ��� � � 7 I I I .i I I 1- I T I L_,, I 1 7 T I I 30 (� L - I I I I I I -- --=-1-I- - 0 I I I I (III I I I I I I I ' 111-, II I I I I I I\I I p I T-J i_ 1 I II )+-- ——1 + �.I I I I L ! ' 11 1 n1 I I O I III 11 c--, - - - I I t I\ I ► — ii. i f1 -�.E. I I I 1 � � n � n 1 \ 1__ / 1 1 I !1 I I I 1 __ r•�I I I I I I-I I I i i I\I I • I 1 _—�. --1 - I - I I I I I I \ I I I I I 1 1 I ` •1 Q. Q,. I \I • I I I\I I \II - ---1J L J r I III 1 \ I �-__ I I I I 11 \II I tgi I J i I I 1 1 I -A L_, I I- -�--- —�I I I I I I i —1 i I i -T y \ I I 1 1 1 1 1 1 \I 1 I I I i --r—�- -- - - } -I---{ r--I I--I r--i I I Imo- \ H 1--il - I�---,I--I--I I I I III I i I I I ' IkV-A (1) I •• I -� I • I I + -_ I Iu I N\ II I 1 I I I L_J I I /1 ---- 1 - +--� I I I II \ II + - III mil I r- 1 1 i i-7r- -r- -�- U I II \ d • r.-.7.71 • -1---I-r=1--t--I-- �I-� --I-- --t----I- I . I I\ 1 I\ I I\ I I i II \II I -�__,�_ , _ ,�_, �_L_ - _ �- i \\ I \ I 1 \ I 1 \ I I I I i I\ II I 1t I I\ I I -,1 I \ 1 I \ I I \ I I U__1__L_ IL-�1__L_I 1\ I XI I I\ I I\ I I\ I LL,Il )0 I \ II I I II I I \ I 1 II I \I I \I I \I LI-I_-1--I--J--1--I--j I \ I I I \ I I \ I I \ I I \ II I I 1 1 1 \ I _J 1 L_, L__1 L_.N I \ 1 1 1 \ 1 1 \ I I \ I 1 \11 I III\1 1 \I F-1 =-- -I --I-- I- 1-- � I \I I I \1 I \I I \I __J_L �1 _ _ L J� -- 1 1 I L _L _-1_- L_Ji J _ L_�I L_J� I--I- 1--a- -I- -J--4---P------- -1 j L rt I I ,,,__=____.,___,,___-_-_b 1 1 I 30 I ri- I--1 I r--1 I I I 1 I I I I I I I I 1 • I i ' I I ! I _ i , ci... a .. I•r--I I r--1 - I _____I___ __L_ L_J I I J. I I I 1 1\ I 1\ I 1\ 1 Lr- c-� - h--1 -�-H---1-- k-==1--j-- CV I\ I I\ I I\ I ■I I \ I I \ I I \ I I\ I 1\ I I I\ II T I \ I I \ I I \ I I \ \ \ i I \ I I II \ I I I \ II I I I \ I I \ I I \ I ' 1 1 1 I I 1 - —I L__N L_�I i__1 I \ I I 11 \ I + 1 \ II— I \I I \I I \I � � � C- F �C r -1 II \I I II \I I I \II L. L-- IL-L_ L_J� L_J� 1 I I I _ _ !_. J 1_ L- ___ - I , fi I , 1 , , I I K=A I �3J �-1 I i i 1 i :...:i a. .I I ... I i I I I + -- O. _ i I CD F � -� F � I I I I I I I I I �! L -1 ril (1..1 I I I I� I I I I 1j 1 Ilr+--1---I--t 1----1-- h—,I ---- h--,1 --� 1 1i �\ I I I r- I I Ir 1 EXISTI ENANT 1 1 I I , EXISTI TENANT GENERAL NOTES— -- - -� --+-- -� --I-- 1�-� i I _ I -- -- - -- -- 1\ I 1\ I I_LHI_1_\I I , rt 4k El OCc ir;;' D.�E \ I I]-- --�-�-- --C'� \\J r- I \\ i li I .I 1,_\ 1 I1\ 1I - a _ . D- P CE , B I I I\ I I\ 1 I I__ I 11 I I I • I I \I! •• II \I _-. I--1 o 3 '. NO We • I I 1 \ I •-1 I \ I 1- 1 \ 1 1 1 I _ ff _ FT I' ' ' I ' ' ' ' ' T r A,. REMOVE CEILING GRID, HANGER WIRES,TILES,I I \I I \I I \I --�_ i �. 1L �I L �1 J ----J L J P \ � \ III �� Z 1 I 1 r --� a �. \ . \ I NOW• K _ -,--c.=--,, ; ---- :_� ----J-� L_� --i-i I 1\ 1 1\ 1, :P F I I I- I -�I I� - --I-��J ; ; ( --- 1-- - + 5 - }--1-� _�'_ L-� AND FIXTURES IN AREAS BEING RETURNED TO a . 1 I\ + I +\ + I + I I I \\ IF-,I \\ I' ``,' jr; 1 i I --kI1--- -- --- d-- I I I I I 0 I 1 \ I I I \ \II il \ 1 I I `\\I III ,I y� 1 I a I 1 I WAREHOUSE. (NOTE:THE HANGER WIRES MAY J_ 1 ill \ ► 1 �/ I \ -7 I I I I L__1 IG__,I L _1!). Ic.��J, I-- 1 1 1, ICI L '-,J .,.i , I i I i _ .K ;:,L_�_ t—I r \ ;�/� -1!r----fi-- -T---- 30 1 Ir= +�- + 1�-�1 + - I + 1 r)-;;Oil '` I ; ; __ I _,I I BE CLIPPED AND THE EYE SCREWS LEFT IN let I I . .mI I I I \1 , \1 I II I M 1 - I-----1-I I I h,� �r � I� I+\ IEtkl� I I I L-_-- t I L- ---,-� I II \ I.. _ . ----rt-- =,1---t1 PLACE FOR FUTURE USE) 0 007 1 I I I I /I I • I h \ 1 r - I-- 1 --1---I--� --I-- --T---- _ { r I ti \I..kk1 1-k1.,1\ II I I I I I 1 \ I -;:'.<,.4 �., 1 \ I FHB” I 1 I i __ op .44,7"5". ..- ,/:, 2225 CA ARTEM ' L DEROSIA CI FLOOR PLAN - KEY NOTES THIS SHEET ' Jr - .-3 . fl 1 RT D, OREGON cii: (N)WALL TO STRUCTURE PER DETAIL 3 ON SHEET A-5 tr' r --- 2 (N)WALL PER DETAIL 2 ON SHEET A-5 /� OF A RE-CONFIGURED THIS SPACE O / 0 \ 3 ALIGN PROJECT #09200 0 REPAIR SURFACES AT REMOVED WALL /� o ENTRY o o u ....4. 1501 0 5 EXTEND GYPSUM BOARD TO STRUCTURE 0 • RETURN THE(E)ROLL-UP DOORS TO WORKING CONDITION. -- - -- ENTRY-'� ENTRY 9� ,�D Ao PROVIDE A NEW STEEL TUBE POST BETWEEN THE DOORS.0 . A I I 19 I I I PROVIDE NEW WEATHER STRIPPING AND A NEW BOTTOM SEAL 108A 102 10 101 \_ iiir . ■11•11111II _- 111 r -I 7 ::: I BLINDS AT EXTERIOR WINDOWS, , O C01> 1548 7 7 ® O o � o ► Q ; _ O 8 OFF MAT 5..1 co N OF ICE e.■ Cr I I I I r ■ ► N I AO W OFFICE O ;4_HALL ,_ . T ■ 103 `� -/ 4 0 • 1 p RETURN THE(E)ROLL-UP DOORS TO WORKING CONDITION. ■ ► 153 0 <N i I '' I PROVIDE NEW WEATHER STRIPPING AND A NEW BOTTOM SEAL. J -N I 1031 T I i ■ • ''� Q p O 0 ■ ∎ 11 RE-FEED(3)EXISTING RECEPTACLES BY ADDING A JUNCTION C�0 (U 153 o D W 41 l F.E. ► _ \ ► I o BOX ABOVE THE EXISTING GYPSUM BOARD TO INTERCEPT THE CD - d-d- 1 I i , %.-.4► _ o NN O 155 (iM) N LINE. (O Cfl BREAK RM ® Id BREAK o W cn© ► � JSTS∎,BOVE ■ T- g C'7 104 r-� ! I _ ∎■ , iFa 152 I 12 ROUGH-IN FOR FUTURE W.C. H O i- 11 � Fa� = cv i; o 41 Li_..' I cc 19,11 v� -0 0 ni Al!)► _� �' �l - .__�■ ROUGH-IN SINK TO ACCOMODATE FUTURE LAVATORY TOILET (152) EL I I I fill, 104 I i -!ri_- I!ll�� _� AID iti�t� ap N ► - •- \- 0 14 (N)WALL PER DETAIL 5 ON A5 105 /► ®;i 0 ' 0 0 ! �� 5? MEN �' '3 �; WO EN I I AC) I I� 0 a �[� 155 F. _.._ j► 154 16 EXTEND WALL ABOVE STOREFRONT TO 10'AFF ,� 6'-1' 6'-1" 7'-11° 4'-10' I ELECT I 111 s'-s" I A i I w INSTALL FIBEROCK AQUA TOUGH IN TOILET ROOMS 107 �• 1 E L CT N., , AC) T Ae PROVIDE(N)GYPSUM BOARD TO STRUCTURE ON THIS WALL � 0 I I ,I' 1 06 I I I CC a _- 107 A®g O REMOVE EXTERIOR LIGHT FlXTURE(S} I- 0 I 1 I I EXIST' Ir TENANT r I- EXIST! ., ENANT WARE OUSE T B - - - - - - - - - - - - - - - - - - - - - - - - _ - D SPACE GENERAL NOTES 3 �CCUI D SP-ACE a 1 6 C� NO WO I I I NO W• K 1. AT INTERIOR SPACES, PAINT ALL SURFACES z>"? o in IF- __ I,� EXCEPT FLOORS,LAY-IN CEILINGS AND J I I WAREHOUSE V I , INSIDE THE ELECTRICAL CLOSETS. AT THE 5 LI 108 ` EXTERIOR, PAINT ALL SURFACES INSIDE m 0 THE ENTRY ALCOVES AND THE OVERHEAD IL i , 1 r , , DOORS ONLY. 4 Z I 4 it A2. PATCH THE GYPSUM WALLBOARD AT ALL 4 REMOVED ELECTRICAL,COMPUTER AND hl TELEPHONE BOXES. BLEND PATCH INTO 0 $ EXISTING WALL FINISH, I I I p I I 3. PROVIDE NEW ROOF-TOP HAVC UNITS TO , ) I' SERVE 16588 AND 16596. PROVIDE NEW r Q DUCT WORK AND GRILLS. I I © I � I I ° �: A 4. AT TOILET ROOMS 154& 155, PROVIDE lli "� :4 ACCESSORIES AND FIXTURES SIMILAR TO 1 E 1 I 0 I DRAWING 7 ON SHEET A5 I < I i Q r o . �� cL _ z 4 I I V I 1 au) - FL®®R PLAN LEGEND 0 w 0) I W ? ° ac 0 - I EXISTING WALL TO REMAIN 3 N O Allalikk q I 1 I 157 O I 44 m ® NEW WALL ®-7 • 1 A Y . .....- . ......, ,...... ....., K 108C ' �;ll� .. �t�t�- c: (.0,,,,,--') Q _ -..... EXISTING DATA/TELEPHONE TO REMAIN in co ELECT O Sac_ EXISTING ELECTRICAL RECEPTACLE TO REMAIN I ' 1 157 7 BAYS AT 24'-7"=172-1" > REVISIONS NEW DATA/TELEPHONE , 8 EuII: 1 . A 4 2 NEW ELECTRICAL RECEPTACLE(DUPLEX) 1 y 2. A SURFACE MOUNTED FIRE EXTINGUISHER 3. 0 6-16-2009 N F.E. 4. 1 FLOORPLAN - NEW 5. 6. A3 SCALE 1/8 = 1' - 0" A ALTERNATE # 2: PROVIDE AN ALTERNATE BID TO REPLACE THE _ DRAWN BY: BASEBOARD HEATING SYSTEM IN 16592 WITH A NEW ALD ROOF-TOP HVAC SYSTEM. REMOVE THE BASEBOARD HEAT. DATE: 5/19/2009 PERMIT SET A ALTERNATE # 3: PROVIDE AN ALTERNATE PRICE TO EXTEND THE tr GYPSUM BOARD TO STRUCTURE AT THE DEMISING WALLS ON GRID LINES 3, 4 AND 5 ON THE WAREHOUSE 108 AND 145 SIDES SIMILAR TO KEY NOTE#5. DO NOT INCLUDE THE INTERIOR OF WAREHOUSE 126. 1 0(t°D 44741'}. C� ARTEM L 25 EROSIA n y 9PORTLAND, OREGON,_. O 1 of & PROJECT #09200 RE-CONFIGURED THIS SPACE A - Cl) EQ EQ SOFFIT PANEL GENERAL NOTES U I 1_, ,, (RE-ATTACH SAGGING n TY' 1. IN-FILL ROOF AT REMOVED HVAC UNITS AND < • a _I, y 1 n RESTORE ROOFING p I O I 0 EQI EQ O I GRID MAINS /?/ 2. PROVIDE WIRE SUPPORT OF BATT INSULATION 1 'MI.....MINLIA1111111■1 -----71 -I I 1 4.j 1---I'�i/ - UNDER ROOF THROUGH OUT PATCH AND REPAIR I I $/) I I i I w N -1- 0 419 �_t-{-!- i_ 3. SERVICE THE UNIT HEATERS IN THE Cr 1 1 ' 1 1 I I WAREHOUSE AND RETURN THEM TO WORKING W BATTERY r ■O� 3 \ CONDITION.PROVIDE NEW THERMOSTATS FOR ® a_.4- BACK-UP EACH. Q N I I I I I I _1 ON ow 17■u/,til - 4. INSTALL WAREHOUSE LIGHT FIXTURES AT 15'AFF O 0 to iii iiiiii © O �` � � � � �� �Q co I \\ '� _ I l - I 5. REMOVE THE SPRINKLER DROPS IN THE Q icr) 'f o) �,,,,,,,-, ,,,,,.,,,,.,\, co WAREHOUSES. MAINTAIN THE REMAINING"UP" N Z (O T ao SPRINKLER HEADS AND MODIFY THEM AS NEEDED W c,)r TO PROTECT THE WAREHOUSE AND MEET CODE. H O - O Q I , � �lc Q F.E. (I) " `r' 6. AT ROOMS 122 AND 123,TUNE UP CEILING GRID < 102 D=..LL< I 1 I I '"' I u€4 I AND REPLACE BROKEN TILES WITH SALVAGED TILE I; Q. :___i FROM OTHER SPACES.PATCH IN GRID WITH ; „„„ SALVAGED GRID FROM OTHER SPACES. I I i I I BATTERY BACK-UP 7. PROVIDE 2x4 FLUORSCENT SURFACE MOUNTED !I WRAP AROUND FIXTURE IN BREAK ROOM 104. a a I I 11 1 I I LITHONIA LB 2 32 MVOLT GEBIOIS co N ari e[ _, r_ ■- ,_ ,q. 1 --N, i 0 ..., ma. I I— I - ( I - - - - -EXISTI ENANT = I F E3 - - OCR r ' D SPACE— - - - , ' ' . - • - -D-SPACE---- - NO •� STEADY BURN WITH I NO W•"I I I W BATTERY BACK-UP K z 0 1 D 5 0 1 I I m 1 0 4 rii, 1 I Z azi I I 'I 1 1 I 4 - , I I I 1 I I t 0 I I r" I I SYMBOLS - REFLECTED CEILING PLAN: f I I � nnuiiuw�mi BATTERY BACK-UP EQUAL EQUAL / / EQUAL EQUAL / 1\ 1 (E) LIGHT FIXTURE T O BE REMOVED 0 I \ I I \ I > . � 4= I I I tU a) 0 1 T T .1=1 W F' (N) 18 CELL PARABOLIC LIGHT FIXTURE i I 1 I I Q O a_ ,_ z BATTERY X EXISTING SUPPLY AIR DIFFUSER Y N. t(f)1 1 BACK-UP I 1 I I (r , \ a EXISTING RETURN AIR GRILL gl EQUAL EQUAL �' , N I I I / / I N- EQUAL EQUAL _ O W r 0 cJ 111 Z t0 ir o EXISTING F IR E SPRINKLER H EAD r 1 ,- In 0 I I i I i_I L'' N c4 Z NEW RELOCATED LIGHT O EW OR LOCATE EXIT L G Z Y - e-4— — f ti Pt It Mil ! —el ? tar' Y w V 0 r Ii 0 433 -- Lo 0 tom-+ co O Vn O r a I i 1 7 BAYS AT 24'-7°= 172'-1' _ REVISIONS C 1 RUUD H1A2X54-U4 2 LMP 54W S 0 @ 0 4 0 i 2 0 1 . e 2. A 3. A 06-16-2009 N 4. 5� 1 REFLECTED PLAN - NEW E!) 6. A2 SCALE 1/8 = 1' - O" DRAWN BY: ALD DATE: 5/19/2009 PERMIT SET A , , , _ t FLOOR AND/OR ROOM STRUCTURE ABOVE ARMSTRONG BERC2 CLIP (AS ALTERNATE MEANS OF lilt).`l. CONSTRUCTION FOR THIS PROJECT) w . yam` CC 0 ' 5/8" PLYWOOD DECK OVER TOILET ROOM Om BLDG. STRUCTURE ABOVE 0 ADDITIONAL HANGERS AT ALL MAINS E ,-� 2-0 = " " ,,∎ 2225 WITHIN 8"OF THE PERIMETER < �;, 0 3 1/2 24 GA METAL STUDS AT 10-0 O.C. �' 3 > �� DEFLECTION CHANNEL TO BUILDING STRUCTURE ABOVE FOR ARTEM ► L. DEROSIA ) __ _ ATTACH JOISTS TO END TRACK WITH 10 X $ (� �t • APPROVED VERTICAL STRUT AT 12'-0"OSCREW EACH SIDE OF EACH JOIST O UNSUPPORTED WALLS LONGER THAN 12'-0" WITH 4 WAY LATERAL BRACING FROM I _ �� CAULKING IN 1/2"SPACE -� +/-45° FASTEN EACH END W/ 1 #8 SHEET METAL SCREW • • (7RUNNERTOTHESTRUCTUREOVER. BEGU\JW1ThBN6-O t U ( ) -�- OF THE PERIMETER AND 2"FROM A CROSS MEMBER )iI $ 16 GA MTL. JOISTS @ 16"O.C. C RELIGHT KIT WHERE SPECIFIED \ PORT • D, OREGON �_ _, -..�,,__. ._r LOCATE DIRECTLY OVER STUDS - R-11 BATT INSULATION - BLOCKING TYP. AT FASTENING POINTS SUSPENDED CEILING q "L 0 6", 6.. . 0 -•,• :_ . -: 6" FIBERGLASS INSULATION T SUSPENDED CEILING ,� I - 3 1/2" BATT INSULATION 2 ON EACH SIDE OF WALL �F 0 ...-_-.---_-._--•. 5/8"GYP BD �� �� � ry::��`�•��'��� � �. � SUSPENDED CEILING 3 5/8 25 GA MTL. STUDS @ 16 O.C. - w PROJECT #09200 •Q - ,► �� (0 - 6"MTL. STUDS 24"O.C. Z ATTACH STUD TO TRAK WITH (2) 7 x 16 On_ O O Q O \-- 3 1/2"MTL. STUDS 24"O.C. SCREWS(ONE EACH SIDE) BOTH ENDS FE ,� Q w a- 0 cv ( -" 5/8"GYPSUM BOARD w �� 5/13 TYPE GYPSUM BOARD u. ADDIITIONAL SWITCH (IN REMODELS MATCH STUD SIZE TO ALLOW �� �� BOTH SIDES SCREW ATTACHED O O GANG LOCATION O REUSE OF BLDG. STD. DOORS AND FRAMES) CO II �- Z U 8" SECURE ALL HANGERS TO BLDG. _I CENTER LINE OF STUD • 0 Z C _ w - MAX STRUCTURE OR A TRAPEZE FOR i/ o CENTER LINE OF STUD o 0 \ . 5" F- w o 5/8"GYPSUM BOARD BOTH SIDES .. DUCT AND/OR PIPE WORK 5/8"W.R. GYP BD 3-1/2 FIBERGLASS fNSULATION Z r• Z O / \ = }<- U o � G�6'-0" MAX CROSS MEMBERS BETWEEN = O oC R-11 BATT INSULATION = U ( 0 *- CENTER LINE OF STUD 4 RUBBER BASE-TYP. Z O O w MAIN RUNNERS o _� O F- _Jr MAIN RUNNERS AT 4'-O"O.C. b ATTACH STUD TO TRACK WITH O w jj �' 4"RUBBER BASE TYP. w0 u. ELECTRICAL > w 3-1/2" BATT INSUL. SUPPORT WITH #12 WIRE AT 4'-0"O.C. s u' �' I OUTLET 1-..S1 = Z OR WITH #10 WIRE AT 5'-0"O.C. �, 10 x s SCREW EACH SIDE OF STUD Z Z w OR J-BOX H F' I 6"RUBBER BASE D 0 A •C =•TTOM TRACK TO FLOOR WITH < CC O o O 4"RUBBER BASE TYP. COUNTERSLOPE HANGERS IF MORE \ 0� ATTACH BOTTOM TRACK TO FLOOR WITH alw p o •.••DER DRIVEN ANCHORS AT 12"O.C. = O O I- I C/7 0 THAN 1:6 OUT OF PLUMB POWDER DRIVEN ANCHORS AT 12"O.C. . , 0 J \ O o ATTACH BOTTOM TRACK TO FLOOR WITH 0 8 fors are FLOOR 0 I UNDERCUT DOOR AS = 6) POWDER DRIVEN ANCHORS AT 1 "O. FINISH FLOOR /� FINISH FLOOR-TOP OF SLAB FINISH FLO R = REQUIRED TO .EAR 00 00 R A 2 C. CC NOTE: ALL CONNECTION DEVICES TO BE IBC � iiI� O FLOOR FINISH T•APPROVED TYPE AND HAVE 100# CAPACITY T FINISH FLOOR RESTROOM SIDE OFFICE SIDE WAREHOUSE OFFICE di l CV 1 2 - 3 q- HEIGHTS 5 TYPICAL WALL SECTION --I Q N o CEILING BRACING SECTION SECTION TOILET ROOM WALL STRUCTURE HEIGHT WALL MOUNTING NEIGHS o�, Os A5 NOT TO SCALE A5 SCALE 1 " = 1' - 0" A5 SCALE 1" = 1' - 0" L5 ) SCALE 1/2" = 1' - 0" A5 SCALE 1" = 1' - 0" CO a oc Fd D W0 d-NI- z (Do W U) o 0o 1' 34" / 33° \ ® l ) o o C ) J < I)0 I X -'mod o: - \ Q 1-0- 0_ -NO Do e -ti :J -6■ )• \ _ = Q � M -0 _ lL / MICRO SHELF AT \ \ -7„\-- � Z , `t O O 2 18'DEEP WITH 2" Qp - AD .S w M c� e� \ UJ >, I I l RADIOUS *- I I I L / \ - Q Q c� p _ ��.��!.►!�l��!�!�! CORNERS N -- -- 1� \ \ \ \ \}-- "�'\ OPEN BACK _ -- SOAP PAPER SAN. NAP. PAPER RECESSED SEAT COVER TOIL. PAPER/ T.P. GRAB BAR MIRROR ip \ \ RUN JOISTS IRROR 36" 1 ' DISPENSER TOWEL DISPENSER TOWEL TOWEL DISPENSER SEAT COV. DISP./ DISP. B-6806 0 a r'_ , q OVER TOILET 3Q36 / / N Imo_ �-- --� B-4112 DISPENSER DISPENSER/ DISPENSER B-4221 SAN. NAP. B-2888 la \ - ROOM IN THIS p \ \ - ( / r - � RECEIVER DISPOSAL � DIRECTION = 1 -/ - Ga T - - - 1-2101 c , kb B-357 i -� N rn B-3944 F.D. i d- USE USG FIBEROCK T PL BAC LASH N ' jWr - ! ' co . . BRAND AQUA-TOUGH 4 mq \ \ j \ —(g ;O- _ \ ' C C INTERIOR PANEL(5/8') T rt I —I o = ADAW e _ ` FORLOWERFOURFEET 'N _ 11 TOILET ROOM ACCESSORY - MOUNTING HEIGHTS °C�„� ; �t �' pp OF THtS WALL AND �t d' a t� ADA WALL [�7 c° I I c� �� 0" ..� �, �_�_--' _ \ HUNG SINK i / /17-12 ao N PLUMBING WALL-USE fi N / 1 A5 SCALE 1/4 = 1 - 0 \ \ �, ®__-- _ _ __ l��/ co \ *- GREEN BOARD FOR d- V I I\►�l�� LL \ \ \ \ \ \ \ \ \ T 1. REMAINDER OF ROOM 3�. 1■ 10 6°RUBBER BASE 1.4 211" 11 ° " 2 47-k 01 / 2 2 / 4/ 33 / 3'-0° / / 68" z 0 3 , J ENLARGED TOILET RM PLAN TOILET RM ELEVATIONS BREAK COUNTER — 6 7 8 5 0 ' �' = ► - 0" SCALE 1 4 = 1' - DOOR SCHEDULE 0 al 4 A5 SCALE 1/4 = 1 - 0 A5 SCALE 1/4 1 0 A5 / 0 • • DOOR DATA FRAME DATA HARDWARE Mark Door Size Thk Core Veneer Finish Hand Type Frame Depth Hardware Manufacturer Finish Function Remarks 101 3'-0'x 7'-0' 1 3/4" SC WOOD STAIN LEFT WOOD 4 3/4° LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N) LOCK-RE-FINISH DOOR Z 14 102 3'-0"x 7'-0" 1 3/4" SC WOOD STAIN RIGHT WOOD 4 3/4' LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N) LOCK- RE-FINISH DOOR_ ROOM F I N I S H SCHEDULE n 103 3'-0'x 7-0' 1 3/4° SC WOOD PAINT LEFT TIM''ELY 8 1/2" PASSAGE LATCH SCHALGE 613 AL1 OS (E) DOOR-(N) LATCH . . WALLS 104 3'-0'x 7'-0' 1 3/4' SC OAK WATCO RIGHT TIM ELY 4 7/8" CLOSER/PASSAGE LATCH SCHLAGE 613 AL1 OS -- 0 RM# NAME FLR BASE CEILING CLG' REMARKS 105 3'-011x 7'-0' 1 3/4' SC OAK WATCO LEFT TIMELY 4 7/8' PASSAGE LATCH SCHLAGE 613 L9486 OCCUPANCY INDICATOR HT. 3/4"WEST _ -NORTH EAST SOUTH WES _ 106 2 6 x 7 0 1 3/4 SC WOOD PAINT RIGHT WOOD 4 7/8 E.T.R. E.T.R. E.T.R. E.T.R. DOOR& E.T.R. _ 101 ENTRY (E)CONC NA CONC-PT/OPEN (E)THB- PT WD WDW WALL-STAIN/THB-PT (E)THB- PT (E) PLYWOOD- PT 9'-0' RE-FINISH WDW WALL 107 2'-6°x 7'-0' 1 3/4' SC WOOD PAINT LEFT WOOD 4 7/8° E.T.R. E.T.R. E.T.R. E.T.R. DOOR&HDWE- E.T.R. 102 ENTRY (E)CONC NA CONC-PT/OPEN (E)THB- PT WD WDW WALL-STAIN/THB-PT (E)THB- PT (E) PLYWOOD-PT 9'-0" RE-FINISH WOW WALL 108A 3'-0'x 7'-0' 1 3/4' SC WOOD PAINT RIGHT WOOD 6" LOCK-CLOSER SCHLAGE 613 N92PD (E) DOOR(N) LOCK - - -- _-- LEFT -- P H L LO E EADB LT E.T.R. E.T.R. E.T.A. DOOR - 103 OFFICE CPT-1 RB WD STRFRT (N)G.B./PT-1 (N)G.B./PT-2 (E)G.B./PT-1 (N)S.A.C. 9'-0° _RE-FINISH WDW WALL 108B 31-0°x 7 0 1 1/2 ALUM/GLASS 5" US /PU UC S R/D O E OOR&HDWE E.T.R. 104 BREAK RM SV RB-1 (N)G.B./PT-1 (N)G.B./PT-1 (N)G.B./PT-1 (E)G.B./PT-2 (N)G.B./PT-1 9'-0' -- 108C 3'-0'x 7'-0" 1 1/2" -- ALUM/GLASS -- LEFT -- 5" PUSH/PULL/CLOSER/DEADBOLT E.T.R. E.T.R. E.T.R. DOOR&HDWE-E.T.R. 105 TOILET SV 6"RB (N)G.B./PT-1 (N)G.B./PT-1 (N)G.B./PT 1 &FBRK/PT-1 (N)G.B./PT-1 &FBRK/PT-1 (N)G.B./PT-1 9'-0" -- 150A 3'-0"x 7'-0' 1 3/4° SC WOOD STAIN LEFT WOOD 4 3/4" LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N) LOCK-RE-FINISH DOOR Lil 106 ELECT (E) CONC (N)G.B. (E)G.B. (E)G.B. (E)G.B. -- 91-0■ -- 150B 2'-8'x 7'-01 1 3/4' SC WOOD STAIN RIGHT WOOD 4 3/4' LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N) LOCK-RE-FINISH DOOR 107 ELECT (E)VCT (E)G.B. (E)G.B. (E)G.B. (E) G.B. -- 9'-0° -- 152 3'-0°x T-0' 1 3/4° SC OAK WATCO RIGHT TIMELY 4 7/8° PASSAGE LATCH SCHLAGE 613 AL1 OS _ 0 - 108 WAREHOUSE CONC. RB @G.B. CONC-G.B./PT-3 (N)&(E)G.B./PT-3 CONC (N)&(E)G.B.-PT-3 O.T.S. 9'-0° RE-FINISH WDW WALL 153 3'-0°x 7'-0' 1 3/4' SC OAK WATCO RIGHT TIMELY 4 7/8' PASSAGE LATCH SCHLAGE 613 AL1 OS j 150 ENTRY CONC NA OPEN-CONC/PT THB/PT WD STRFRT/STAIN THB/PT THB/PT 9'-0° -- 154 3'-0'x 7'-0' 1 3/4' SC OAK WATCO LEFT TIMELY 4 7/8" PASSAGE LATCH SCHLAGE 613 L9486 OCCUPANCY INDICATOR <( 151 OFFICE CPT-1 RB WD STRFRT/STAIN (N)G.B./PT1 (N)G.B./PT1 (N)G.B./PT1 (N)G.B./PT1 (N) SAT 9'-0" -- 155 3'-0"x 7'-0' 1 3/4' SC OAK WATCO LEFT TIMELY 4 7/8° PASSAGE LATCH SCHLAGE 613 L9486 OCCUPANCY INDICATOR Q " 157 2'-6°x 7'-0° 1 3/4' SC WOOD PAINT RIGHT WOOD 4 7/8' E.T.R. E.T.R. E.T.R. E.T.R. DOOR&HDWE- E.T.R. _ z 152 BREAK VCT RB G.B./PT-1 G.B./PT-1 G.B./PT-1 G.B./PT-1 S.A.T. 9-0 -- - - N 153 HALL VCT RB G.B./PT-1 G.B./PT-1 G.B./PT-1 G.B./PT-1 S.A.T. 9'-0° -- C 154 WOMEN (N) SV (N)RB (N)G.B./PT1 (N)G.B./PT1 (N)G.B.-AQT/PT1 (N)G.B.-AQT/PT1 (N)G.B./PT1 9'-0° -- < 5 d. 155 MEN (N) SV (N) RB (N)G.B./PT1 (N)G.B./PT1 (N)G.B.-AQT/PT1 (N)G.B.-AQT/PT1 (N)G.B./PT1 9'-0' -- (D N 156 WAREHOUSE CONC RB @GB G.B./PT3 G.B./PT3 CONC G.B./PT3 O.T.S. 9'-0° -- 2" -- 3 4" 2 14' 14° 114" 17' 17' 17' 17° W 0) 157 ELECT E.T.R. E.T.R. E.T.R. E.T.R. E.T.R. E.T.R. E.T.R. 9-0 / // / / / 1 / / / / W UJz2a: cc CA T O FINISH MATERIALS - (TAN SCHEME) - — \ .. D SAMPLAES OF ALL FINISHES MUST BE SUBMITTED TO ARCHITECT PRIOR TO INSTALLATION. iv w N Q Z C4 Z ABBREVIATIONS r r T � O CARPET LOOP PILE: ____ CPT-1 PATCRAFT 10147-FAMOUS LAST WORDS II, 47200 LOOK NO HANDS, DIRECT GLUE ' i _ =-- ` ` : : ::: i i -11\ i ` ` V 0 F- _ ADJ ADJUSTABLE I / - :::_ I /I 1 I I P-LAM In CC CONTACT FOR PACTRUST PRICING&ORDERING INFO:IVY O'BRIEN 503-754-6826 == . AQT USG'S FIBEROCK AQUA TOUGH Co PL-1 - oo = ===` I / I I / \ I I \ I END Q+ (0 0 WALK OFF MAT BLDG BUILDING P.LAM I / i : _= V j VAN DIJK CONTRACT,#41,4'x 4' END - =-: _ = =-----=------= + I ADJ.SHELF ' 1 CONC CONCRETE \ N _...:.:.:._:.:-_-- i \ 1\ PL-1 I 1 0 REVISIONS VINYL COMPOSITION TILE CPT CARPET VCT ARMSTRONG 51839 FORTRESS WHITE 12'x 12"X 1/8" (E) EXISTING TI ....� TIN I i t I I I e E.T.R. EXISTING TO REMAIN N g\\N N i i : \ SHEET VINYL GA GAUGE .-....._: . \ - _1 tL \ _J 1 \ 2. A. SEAMS NOT PERMITTED-EXPOSED EDGES(AT 1-IN Co 1 �o m SV ARMSTRONG MEDINTECH, 86412 OATMEAL, S { G.B. GYPSUM BOARD 1- *- DOORS OR OPENINGS TO HAVE TRANSITION STRIPS--SUBMIT OPTIONS AND COLORS TO GYP. BD. GYPSUM BOARD ` 1 N. ""1�- 3. A 06-16-2009 ARCHITECT FOR APPROVAL CONTACT FOR PACTRUST PRICING&ORDERING INFO:MARK JONES 503-201-3657 IBC INTERNATIONAL BUILDNG CODE - - © ED - �� — N of 4- S g g g BASE MAX MAXIMUM - - N 5. RF BURKE MERCER 4"FLAT RUBBER BASE,597 MOCHA AT ALL CARPET AREAS. MIN MINIMUM = \ _ _ \ RC BURKE MERCER 4"COVE RUBBER BASE, 597 MOCHA AT ALL HARD SURFACES MTL METAL �\ [ \ - - \ \ 6. EXCEPT USE 6"IN TOILET ROOMS. I I ::: �::::: :::: _::: - _ I I , _ (N) NEW P.LAM I I F:: ::: :::-:: ::_:: :::: - - 1 ° I I I m NA NOT APPLICABLE END \ 1 _ ::::::_: ::::::-::_:_:•: :: :-_: =-- .: t r t� --1 I ::-.-:_::::-:::..�_::.-::-:-_:__:= :_ - -- - ADA SINK I P.LAM T-1 MILLER 4480 PREMIUM SATIN 8721W CLAY BEIGE,SATIN LATEX. 1I \ I :_.___-_ :-:.:::::-: :- - - - ► I P O.C. ON CENTER _ _ _ _ I - - I ;I -- - - - I END PT-2 MILLER 4480 PREMIUM SATIN 8724M MEADOWLARK,SATIN LATEX (ACCENT COLOR) k __ _::., Y I O.T.S. OPEN TO STRUCTURE - _ c7 PT-3 MILLER 3780 PREMIUM FLAT-MIX IXX79W(WAREHOUSE WALLS) I /I ::::::::..:.::::._::::.:::::::.. _..._:_...__-._:,__._..__._.;,_.::_...:.:_: < 1 > G T 8 0 PL PLASTIC LAMINIATE I -- I I ' / I I DRAWN BY CONTACT FOR PACTRUST PRICING&ORDERING INFO:AMY TACKE 503-34 -03 7 I / 1 : :: : :: : ::: _ _ -: __ : 1 \ I I / I PT PAINT 1 I = _ 1 I I I ALD LAMINATE: PS PLAIN SAWN - ,_ _� �- --:-_-:-:--:_ :_ \ .........:..::..:._.-_:::-== 1 � __------ --�__ i �\ \ \ DATE: 5/19/2009 PL-1 WILSONART 1530-60 BEIGE,AT ALL FACES RC RESILIENT COVE BASE 1■ PL-2 WILSONART 4669-60 NATURAL TIGRIS COUNTER-TOP, BACKSPLASH AND SELF EDGE. 3■ _ PERMIT SET RESILIENT FLAT BAS �� �� 24" 1 ■ ■ RF E / 22 #4 24 / / 24 //4 17 / 17 / 17 / 17 / S.A.C. SUSPENDED ACOUSTICAL CEILING CONTACT TECH SERVICES: 800-433-3222 34■ CAB PULLS 613 OIL RUBBED BRONZE STRFRT STOREFRONT / / - SV SHEET VINYL DOORS,HARDWARE AND FRAMES THB TEMPERED HARD BOARD DOORS PS RED OAK FINISH PAC WATCO TYP TYPICAL Y {: MFGR PACIFIC ARCHITECTURAL WOOD PRODUCTS,INC. WD WOOD ADDRESS 714 NE 55TH AVENUE PORTLAND OR 97213 WDW WINDOW T ELEVATIONS B R E�,K ROOM CAB I N E FAX:(503)284 107 HARDWARE 613 OIL RUBBED BRONZE Co)ASCALE 1/8 = 1' - 0" FRAMES BROWN TONE - 01 00 00 GENERAL DATA 09 21 00 GYPSUM BOARD b. GALVANIZED METALS: D. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION AND 24- �, 4741) 1. NEW-WASH WITH GALVA WASH SUBSTANCE, PRIME WITH ALKYD PRIMER,AND FINISH WITH EXTERIOR ACRYLIC HOUR USE. ,UARTEIR� �j GENERAL REQUIREMENTS GENERAL TO ACHIEVE UNIFORM COVERAGE. 3. PACTRUST PREFERENCE IS ZONES TYPICAL 3-5 TON BASED ON USE&EXPOSURE CRITERIA. ZONE LOADS '� THE LATEST EDITION OF THE 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH 1"TYPE S- 2. EXISTING-SPOT PRIMER WITH ALKYD OIL PRIMER AND FINISH WITH EXTERIOR ACRYLIC TO ACHIEVE UNIFORM GREATER THAN 5 TONS FOR PACKAGED OR SPLIT SYSTEM EQUIPMENT SHALL BE SPLIT INTO MULTIPLE ZONES. DEROSIA C�1. ALL COATIONAL I UI WORK SHALL BE TEND ID BY HEIANAT WITH E LA 12 SCREWS 12"O.C. UNLESS OTHERWISE NOTED. COVERAGE. ZONE LOADS GREATER THAN 3 TONS FOR VAV OR H2O SOURCE HEAT PUMPS SHALL BE SPLIT INTO MULTIPLE � y INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF OREGON AND ALL OTHER STATE OR LOCAL ZONES.CODE REQUIREMENTS THAT APPLY. 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TWO FINISH COATS WITH SANDING BETWEEN FINISH c. ALUMINUM-NEW OR EXISTING, PRIME ALL RAW ALUMINUM WITH VINYL WASH PRIMER AND FINISH WITH EXTERIOR • 2. CONTRAC TOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING � COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. ACRYLIC TO ACHIEVE A UNIFORM COVERAGE. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. PORTLAND, OREGON BUILDING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH COAT WITH SANDING AFTER FINISH COAT. 4. CONCRETE WALLS: 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. Q PAINT AS INDICATED. TRANE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 TONS 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING a. NEW-PRIME WITH KRILL PRIMER SEALER AND FINISH WITH HIGH SHEEN KRILL TO ACHIEVE UNIFORM COVERAGE. 6. UNITS: LENNOX, ;.f ) OW PRIOR TO SUBMITTAL OF A PROPOSAL. SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 4. AT ALL EXISTING WALLS,REMOVE ALL NAILS,SCREWS, FASTENERS, ETC. LEFT BY PREVIOUS TENANT AND PATCH b. EXISTING-SPOT PRIME WITH KRILL PRIMER SEALER AND FINISH TO HIGH SHEEN KRILL TO ACHIEVE UNIFORM SHALL HAVE SPECIAL APPROVAL BY PACTRUST. OF CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE HOLES READY FOR PAINT. COVERAGE 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCTED SMOKE DETECTION AND BE CONNECTED TO THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 1 0 00 00 SPECIALTIES A MONITORING STATION WITHIN THE BUILDING. PROJECT #09200 5. UPON REMOVAL OF ANY WALL BASE MATERIAL,CONTRACTOR TO PREP WALL TO PAINT READY CONDITION. 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 8. UNIT PLACEMENT 24'MINIMUM TO CENTER FROM ROOF EDGE. MULTI-PLACED UNITS SHOULD BE SYMMETRICALLY EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK WALL CONSTRUCTION MATERIALS 10 28 13 REST ROOM ACCESSORIES IN A LINE BASED ON STRUCTURAL CALCULATIONS BY STRUCTURAL ENGINEER. ---DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 1. PROVIDE STUDS,TRACKS,BRACING, FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE �n ALL MATERIALS AND INSTALLATION, DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE 1. REUSE EXISTING ACCESSORIES WHERE POSSIBLE. 9. CURBS: 14"CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS BELOW VJ LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST), CLEANING AND ALL PREPARATION OF SUBSTRATE INSTALLATION. ROOFING. SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED.WHERE PHYSICAL STRUCTURAL 2. PAPER TOWEL DISPENSER,SURFACE MOUNTED(ONE PER REST ROOM)BOBRICK B 262 U PROPERTIES ARE NOT INDICATED, THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LOADS. DESIGN 3. SURFACE WALL MOUNTED SOAP DISPENSER BOBRICK 8-4112(use with wall hung sink) A. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST SELECTED ROOFER. SEE DIVISION 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN THE EXISTING BUILDING ' 1 GENERAL NOTES THIS PAGE. -- STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS FRAMING IN ACCORDANCE WITH NISI SG-673. 4. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER BOBRICK B-2888 B. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. < INTENSION, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 PSI)G60. C. CONDENSATE MUST BE TRAPPED AT UNIT. �. 5. SURFACE MOUNTED TOILET SEAT COVER DISPENSER BOBRICK 13=4221 6. FURNISH ALL NEW MATERIALS EXCEPTWHERE SPECIFICALLY NOTED OTHERWISE. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PAC IFIC,NATIONAL GYPSUM OR AN SUPPORTED BYA CONTINUOUS 10. SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED FASHION. APPROVED EQUAL. 6. MIRROR STANDARD SIZES 1/4"PLATE MIRROR WITH EDGES"FLAT GROUND"BOTTOM EDGE . ' 7. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-OFF MATS"TO BRIGHT CHROME"J"METAL,5/16"X 3/8" (HEIGHT OF EXPOSED FACE)WiTH CONCEALED LEG SCREWED TO THE WALL TO 11. ANY GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN INSIDE PROTECT EXISTING CARPETS. 5. STANDARD GYPSUM BOARD SHALL BE 5/8"THICK WITH TAPERED EDGES CONFORMING TO ASTM C-36. CARRY THE WEIGHT OF MIRROR. OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND CLAMPED(S.S. <IC WORM GEAR). 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AS 6. USG FIBEROCK BRAND INTERIOR PANEL-AQUA TOUGH. 5/8"THICK,TAPERED EDGES. 7. GRAB BAR SATIN FINISH BOBRICK B-6806 SERIES Cl) p NEEDED. 12. ALL EXISTING AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND CORROSION O 7. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. 10 28 13 BREAK COUNTER WITH OIL BASED PAINT(COLOR GREY). 0 0 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED COMPANIES INCLUDE: WALL CONSTRUCTION EXECUTION 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 13. LOW VOLTAGE WIRING SHALL BE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT Cr A. ANDERSON ROOFING, (503)294-0202 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING SCREWS. 10 44 16 FIRE EXTINGUISHERS EXCEED BEND RADIUS MANUFACTURER'S GUIDELINE. W B. PACIFIC ROOFING (503)640-3163 WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW CONNECTIONS SHALL BE 14. ECONOMIZER TO MEET CODE AND AS FOLLOWS: C. GRIFFITH ROOFING (503)643-1596 AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD MATERIALS LIGHTER THAN 18 GA. 1. FiRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) A. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. 0 0_N D. GARON ROOFING AND SHEET METAL (360)254-0380 Rick NIMa I a 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS INDICATED IN 2. FIRE EXTINGUISHER CABINET: B. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. 10. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. FASTENERS SHALL BE AT C. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. - < DOCK ACCESS AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 12 OO 00 FURNISHINGS D. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. 0 6- 0 Lo 11. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION STUDS 1. CONTRACTOR TO REPLACE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS AND PROVIDE BUILDING STANDARD 15. ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. Cl) 0 CC CO N NOT LIMITED TO BUILDING ENTRANCES,LANDSCAPING, ETC. THE CONTRACTOR WILL BE RESPONSIBLE FOR VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT LEAST TWO FULL (MINI)BLINDS TO MATCH AT EXTERIOR GLASS(EXCLUDING DOORS). 16. DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM 26 GAUGE WITH SUPPLY AIR. EDGES OF SUPPLY AIR W 0 N.i THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION ACTIVITIES. HEIGHT KING STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE JACK STUDS OVER 2. CONTRACTOR TO INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. SEALED. DROP CANS TO BE EXTENDED TO WITHIN 2'OF CEILING. U)0 N N 12. CONTRACTOR TO PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TRIPLE STUDS AT CORNERS, p N POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP AND BOTTOM TRACKS BY T 12 23 16 CABINET SPECIFICATIONS 17. DISTRIBUTION DUCTWORK: Z BUILDING RESTROOM FACILITIES. WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. PROVIDE DEFLECTION HEAD AT ALL WALLS WHICH EXTEND W (j'� 13. STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT PRE- TO THE UNDERSIDE OF THE ROOF STRUCTURE. 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. A. SPIRAL DUCK WORK PERMITTED ONLY IF EXPOSED TO VIEW. 0 g O O B. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER ri 41"9 COMMON BUILDING AREA BE USED FOR STORAGE. 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR THE 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O. C. IN NON-CONDITIONED AND SEMI CONDITIONED SPACES, � �(r `. PROJECT. D. WRAP CONCEALED SUPPLY DUCTWORK WITH MINIMUM R4.2 INSULATION WITH FSK BARRIER. 3. HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES, INCLUDING 4 TOE KICK. EDGE BANDING(MATCHING to 0 I X 14. CONTRACTOR SHALL KEEP THE ROOF FREE OF DEBRIS(I.E. NAILS,SCREWS, BOTTLES, ETC.)AT ALL TIMES. 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. PVC ACCEPTABLE),FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS OPTIONAL HPL FINISH„ E. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD HANGERS < r U_ 15. ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH, STANDARD MELAMINE FINISH. AND FULL DIAMETER STRAP UP TO 18"0. LARGER THAN 18"MUST HAVE SADDLE TYPE CLAMP. 6. FINISH QUALITY: F. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 DEGREES. 16. CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL, MECHANICAL, AREA PROCESS TRADE NOMENCLATURE 4. TOE KICK PLYWOOD 4"HIGH WITH P-LAM COVER G. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. WAREHOUSE TAPE/FINISH COAT* TIGHT DOUBLE 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16"PARTICLE BOARD WITH MATCHING P-LAM OR PVC EDGES. H. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE DROP CEILING. 17. LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. OFFICE/OTHER AREAS TAPE/2 FINISH COATS*/ SMOOTH FINISH TAPED 6. MELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS, DRAWER PARTS,SHELVING ETC. 18. FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. >"' 18. CONTRACTOR TO CLEAN ADJACENT EXTERIOR AREA, I.E.WALKS, EXTERIOR GLASS, ETC. USG"FIRST COAT" *SAND AFTER TAPE/FINISH COAT(S) 19. DIFFUSERS: I' 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR TEXTURE AND/OR 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. 19. CONTRACTOR TO FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. FINISH AS SHOWN ON PLANS. 8. HINGES-BLUM#75M3580, 110 DEG.SELF CLOSING CLiP ON(OR EQUAL). A. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN TITUS PCS a a SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. 20. PROVIDE"AS-BUILT'DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT' 8. INSTALL FIBEROCK AQUA TOUGH AT TOILET ROOM WALLS BEHIND AND ADJACENT TO THE WATER CLOSET. LAY 9. DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS. MIN. FOR STANDARD DRAWERS. B. GYP. BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250; RETURN-BAR TYPE-DESIGN TITUS 350; iiii DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED HORIZONTAL,WALL TO WALL WITH NO JOINTS FROM FINISH FLOOR UP FOUR FEET. EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS 10. PULL-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. , C. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT/OR NEAR CLOSEST WYE N SHALL BE PROVIDED FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT. PACTRUST MAY HOLD 09 53 00 SUSPENDED ACOUSTICAL CEILING 11. GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WiTH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. SINK BRANCH. 'T CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED AND CUTOUT WiLL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL CASES TO ALLOW CUT CC 0 APPROVED. 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. D. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT COMPLETION. cc a OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH TO BE SEALED. MINIMIZE f-- 21. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDES A COMPLETE, 2. FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING SYSTEM, COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CUT OUT TO ACCOMMODATE PLUMBERS SINK CLAMPS 20. THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE a FUNCTIONING PROJECT INCLUDING ALL GENERAL, MECHANICAL AND ELECTRICAL CONSTRUCTION REQUIRED INCLUDING GRID, PANE LS,AND HANGARS AND ACCESSORIES. CLEARANCE. HONEYWELL COMMERCIAL GRADE VISiONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. ..:: REGARDLESS 4" APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY AND INSTALLED, RE RDLES OF TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AN 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES, INC. 12. KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4 BACK SPLASH. ALL WHETHER OR NOT SHOWN ON THE DRAWINGS. CABINETS TO HAVE DOORS AND DRAINERS U.N.O. UPPERS 12"D X 36"H COUNTER AND COUNTERTOPS 26"D. PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY REQUIRE r IMM 4. CO-ORDINATE CEILING WORK WITH INSTALLERS OF RELATED WORK INCLUDING BUT NOT LIMITED TO INSULATION, CHANGING HEIGHT AT"REPLACEMENT'LOCATIONS). CONTRACTOR SHALL PROGRAM THERMOSTATS AND r 22. ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". GYPSUM BOARD, LIGHT FIXTURES, MECHANICAL SYSTEMS, ELECTRICAL SYSTEMS AND FIRE SPRINKLERS MICROWAVE SHELF 18"D WITH 3"RADIUS OUTSIDE CORNERS. P-LAM AT TOE/BASE. ALL SHELVES ADJ. HOLES AND POSTS BALANCE SYSTEM. (1 AT BASE,2 AT UPPERS). D 21 23. "ALIGN"AS USED IN THESE DOCUMENTS, MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME 5. PRODUCTS: 21. THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. 0 PLANE, EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR ACROSS AN OPENING. 21 00 00 FIRE SUPPRESSION z 24. DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS. DRAWINGS ARE INTERRELATED. a. GRID-PRELUDE 24 XL 15/16"EXPOSED TEE(HEAVY DUTY) 22. WAREHOUSE HEAT: b. TILES-ARMSTRONiG FISSURED ITEM#705,24 x 24 x 5/8"W/ANGLED TEGULAR EDGE 1. PROVIDE SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE CENTERED IN 2 X 2 CEILING A. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE ENERGY J 25. SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES TO THE ARCHITECT OF RECORD WITHIN TWO WEEKS C. ACCESSORIES-MANUFACTURERS'STANDARD TILE. LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD CEILING AREAS(GYPSUM Fil Li OF PROJECT AWARD.PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO REPLACEMENT BOARD/PLASTER TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. CODE REQUIREMENTS. PROVIDE ADJUSTABLE T-STAT FOR EACH UNIT. 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE BOARD/PLASTER) AT CONTRACTOR COST. CONDITION SO THAT CEILING TILE LAYS FLAT. 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. NO"OOPS B. RETURN INACTIVATED UNIT HEATERS TO ACTIVE USE.SERVICE UNITS AS REQUIRED. m 26. CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS, MECHANICAL, 7. AT CEILINGS OVER 144 SF PROVIDE HORIZONTAL RESTRAINT WIRE OR RIGID BRACING. RINGS ALLOWED". 23. EXHAUST FANS: all ELECTRICAL AND PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF TWO COPIES OF ALL SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT 8. AT CEILINGS OVER 144 S.F.: 3. PROVIDE AUTOMATIC FIRE SPRINKLER FLOW INDICATOR SIEMENS CU-MHU-MCS-W OR EQUAL. LOCATION TO BE APPROVED A. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT CODE Z .,41 WILL RETAIN ONE COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. BY ARCHITECT. REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR.COOK GEMINI a. INSTALL GRID USING BERC2 CLIPS TO ATTACH GRID TO WALL MOLD AS AN ALTERNATE MEANS OF CONSTRUCTION SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, 100 CFM WITH A SONE RATING OF.9 OR INk 27. THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS FOR THIS PROJECT WITH TWO ADJACENT SIDES RIGIDLY ATTACHED AND THE OTHER TWO SIDES ALLOWED TO 22 00 00 PLUMBING LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. I CONTRACTOR.ALL FiRE PROTECTION SYSTEMS SHALL BE DESIGNED BYA PROFESSIONAL ENGINEER FLOAT. B. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING MOUNTED LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE GENRAL REQUIREMENTS EXHAUST FANS,WIRED BY DIVISION 16 AND SWITCHED WITH THE LIGHTS. INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE 9. PROVIDE RIGID STRUTS TWELVE FEET ON CENTER EACH WAY BEGINNING WITHIN SIX FEET OF PERIMETER EDGE. 24. HVAC TESTING. 0 ' • CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE INSTALL SWAY BRACING EACH STRUT ALONG FIXED EDGE IN ALL FOUR DIRECTIONS 1. PLUMBING CONTRACTOR TO PROVIDE AND INSTALL(1)MASTER SHUT OFF VALVE FOR EACH SET OF RESTROOMS. LOCATE APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS SHALL BE PRE-APPROVED IN WRITING BY VALVE BEHIND WATER CLOSET IN MEN'S RESTROOM. A. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT AND 10. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES AS NEEDED. TUNE UP GRID SYSTEM AS NEEDED. SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND THE ARCHITECT PRIOR TO INSTALLATION. 2. WATER HEATER(ELECTRIC)5 GAL, 120V. PROVIDE OVERFLOW DRAIN TO FLOOR DRAIN BELOW. SPECIFICATIONS. < ' 28. THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE 11. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE ACCEPTABLE. B. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE 3. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS WITH APPROVED PLANS AND SPECIFICATIONS. ALL SERVICE INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT 09 65 19 RESILIENT FLOORING -RESILIENT FLOORING C. A COMPLETE APPROVED PLANS COMMISSIONING REPORT SPECIFICATIONS. TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED TENANTS. 4. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. PROVIDE A MIN. OF 18"ACCESS DOOR. 1. PLACE A CONTINUOUS BEAD OF SEALANT TO SEAL THE EDGE OF THE VINYL FLOORING TO THE WALL. AS THE 6" WITH PACTRUST. GENERAL RUBBER BASE IS INSTALLED,APPLY A BEAD OF SEALANT TO SEAL THE RUBBER BASE TO THE FLOOR AND THE TOP OF PLUMBING - REST ROOM FIXTURES (SINGLE OCCUPANCY) 25. PROJECT CLOSE OUT DOCUMENTS REQUIRED: 1. REMOVE ALL EXISTING VCT,SHEET VINYL, ETC. IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR THE RUBBER BASE TO THE WALL, 1. REUSE EXISTING FIXTURES WHERE POSSIBLE A. AUTOCAD FILE SHOWING AS-BUILT INFORMATION. W TO INSTALLATION OF NEW FLOORING. 09 91 23 PAINTING 2. FLOOR MOUNT TANK TYPE WATER CLOSET- TOTO CST744SL OR KOHLER CIMARRON K3496 B. HARD COPY OF AUTOCAD FILE ABOVE. 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GAS PIPING, ETC. SHALL BE SLEEVED THROUGH A INTERIOR: C. OPERATIONS MANUALS FOR ALL EQUIPMENT, INCLUDING T-STATS. LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VOLKUM CAULKING. 3. LAVATORY FAUCET DELTA 501 WF D. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. C..) SILICONE SEALANT NOT PERMITTED. 1. WALLS: 4. PROVIDE FLOOR DRAINS WHERE INDICATED. W 26 00 00 ELECTRICAL < . a. PRIME NEW DRYwiALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. Q 01 23 00 ADD ALTERNATE PRICING REQUIRED b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480 WITH 5. CAULKING OF PLUMBING FIXTURES: A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S S/G LATEX ENAMEL. A. ALL CAULKING SHALL MATCH GROUT COLOR AT TILE SURFACES. GENERAL 0 1. _ Z 2. DOORS AND FRAMES: B. SUBMIT CAULKING COLOR PRIOR TO INSTALLATION FOR ARCHITECT APPROVAL FOR ALL OTHER APPLICATIONS. 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES, ETC. MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. EXCEPT 03 00 00 CONCRETE PLUMBING - REST ROOM FIXTURES (MULTI OCCUPANCY) HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD WILL BE PERMITTED. Y a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL. 2. UPDATE ALL PANEL SCHEDULES TO CURRENT CONFIGURATIONS. (J) 1. EXTERIOR FLAT WORK: b. EXISTING HOLLOW METAL-SAND, FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH ALKYD 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. Q PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. 3. ELECTRICAL CONTRACTOR TO PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING Cl_ CD d' a. 4"THICK UN-REINFORCED CONCRETE SLAB WITH AIR-INTRAINMENT OVER 4"COMPACTED CRUSHED ROCK C. NEW WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND, FILL ALL FASTENING HOLES WITH PAINTER'S PUTTY, 2. COUNTERTOP LAVATORY KOHLER K-2196-4 CORRESPONDING ELECTRICAL PANEL AND CIRCUIT BREAKER. Cfl N (3/4 MINUS). CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK,AND FINISH WITH S/G 3. LAVATORY FAUCET DELTA 501 WF W CD) N. b. CONTROL JOINTS 5'O.C.MAX, EXPANSION JOINTS 20'O.C.OR AS SHOWN ON PLANS. 4. CONTRACTOR TO VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. C. BROOM FINISH WITH TOOL EDGE EACH SIDE. OIL ENAMEL. d. EXISTING WOOD-PREP,REPAIR IMPERFECTIONS, PRIME AS REQUIRED,AND REPAINT WITH SEMI-GLOSS OIL 4. TOILET W/FLUSHOMETER-AMERICAN STANDARD AS 2234.015 AT NON ACCESSIBLE STALLS AND 2305.100 AT ACCESSIBLE METER IDENTIFICATION NUMBER,LOCATION AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO ARCHITECT CD _ LOCATIONS. FLUSHOMETER SLOAN FLUSH VALVE 111 OR TANK TYPE TOTO CST744SL AS INDICATED ON PLAN PRIOR TO TENANTS MOVE-IN. Z pc 07 00 00 THERMAL & MOISTURE PROTECTION ENAMEL. IF FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL AS REQUIRED,AND RE VARNISH WITH SATIN VARNISH. U) ' 0 CEILING RI 3. CEILINGS: 5. URINAL-TOTO UT104,OR KOHLER K-5016-ET W/FLUSH VALVE SLOAN 186-1 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXiT PATH EQUAL TO 1-FOOT CANDLE. D N DAMAGED ROOF AND WALL INSULATION ABOVE THE E LING G D 38" 42" u " 1. AS TO REPLACE ALL MISSING OR DAM ED R 6. FOR EXIT LIGHTS USE RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE m 0 AS NEEDED. a. EXISTING PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO ACHIEVE UNIFORM 6. SLOWER STALL FIBERFAB ASSISTED LIVING MODEL#38-H1-LP WITH ROUGH OPENING OF 38 WIDE BY 42 DEEP. I� l� HOUSING,WITH BATTERY BACKUP. 0 Z p Z 2. CONTRACTOR TO INSTALL NEW ROOF INSULATION TO MATCH EXISTING iN ALL ABANDONED HVAC UNIT COVERAGE WITH MILLER'S 6200 OR 4480. 7. PROVIDE ONE FLOOR DRAIN IN EACH RESTROOM LOCATED UNDER TOILET PARTITION. 4.1 r- Q b. NEW PLASTER-PRIME WITH SUPER SEAL AND FiNiSH TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 7. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE 208V/120V ® J LOCATIONS. W 4 480. A I XTURE S T PO W ER FR M THE 480V/27 V SY ST EM. SfZ TO BE BIDDER DESIGN. � �- 08 10 00 DOORS AND WINDOWS 4. GENERAL NOTES: A. SUBMIT SEALANT COLOR TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION a. TRANSFORMERS TO BE ENERGY STAR LABELED. a. KEEP ALL HARDWARE, HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS, DRIPS,OR ROLLER SPRAY. PLUMBING - BREAK ROOM FIXTURES b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE INTERIOR. V 0 a 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE c. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION,DESIGNED FOR 115 DEGREES C I b. ALL SURFACES TO BE�SANDED�BETWEEN COATS, PRIOR TO INSTALLATION OF NEXT COAT. � 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS OPERATION. 2 TIMELY FRAMES SHALL BE II,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING MATERIAL. NUEW FRAMES T TO BE (AAP), c. DURING PROGRESS OF WORK, KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS, RUBBISH,CANS,AND RAGS AT THE REVISIONS EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM SOUND LEVEL SHALL END OF EACH DAY. 2. BREAK ROOM SINK ELKAY CR-2522 BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL ASSEMBLY AND CASE. R�j � 1N S FACTORY FINISH CUSTOM COLOR. d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING AND 3. FIELD VERIFY EXISTING FRAME FINISH PRIOR TO ORDERING NEW FRAMES. ALL NEW FRAMES TO MATCH SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. 3. KITCHEN FAUCET DELTA 100-WF 8. TELECOMMUNICATION SYSTEM BY FUTURE TENANT. EXISTING BUILDING STANDARD FRAMES. e. PROTECT WORK OF OTHER TRADES. 23 00 00 HVAC 9. WHEN REQUIRED IN DIVISION 15, PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. 1 . f. PROVIDE WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. 4. ALL DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. 10. CONTRACTOR TO REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION- 2. EXTERIOR: GAS METER 5. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. UNUSED DATA BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD n 5" 1. WASHING: 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANT SPACE ADDRESS OR SUITE NUMBER. METER FINISH. 3. / \ 06-16-2009 6. ALL HARDWARE SHALL BE INSTALLED WITH A 5 BACKSET. IDENTIFICATION NUMBER AND ADDRESS INFORMATION SHALL BE GIVEN TO ARCHITECT PRIOR TO COMPLETION. 7. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES, DOOR HARDWARE a. ALL SURFACES TO BE PAINTED ARE TO BE PRESSURE WASHED USING A PRESSURE WASHER WITH A MINIMUM OFFICE LIGHTING 4,. PRESSURE OF 2500 PSI. HVAC - BID PROCEDURE AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH APPLIED(IF 1. OFFICE LIGHT FIXTURES-LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL.(NO SYLVANIA BALLASTS) NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT SHALL b. AFTER WASHING: 1. FOR BIDDING PURPOSES,THE HVAC CONTRACTOR WILL ASSUME THAT EXISTING HVAC EQUIPMENT IS IN PROPER 5. 2. REST ROOM WALL MOUNTED LIGHT FIXTURE -LITHONA WC 2 32 MVOLT GEB101S OR EQUAL APPROVE CONTROL SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS PROCESS 1. DO NOT PAINT OVER DIRT, RUST, SCALE,GREASE,AND MOISTURE. SCRAPE ALL SURFACES TO REMOVE ANY WORKING ORDER. IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATCH THE APPROVED CONTROL SAMPLE. SCALE. 2. INVENTORY EXISTiNG H.V.A.C.ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH UNIT 3. RECESSED DOWN LIGHT: RUUD LIGHTING R7FT,6"FLUORESCENT QUAD TUBE(2-13W) 6. 8. ALL INTERIOR GLAZING SHALL BE TEMPERED. 2. ALL IRREGULAR SURFACES TO BE FEATHERED OUT AT EDGES BY SANDING. 4. EXTERIOR SOFFIT DOWN LIGHT: RUUD LIGHTING R7FEM 6"QUAD TUBE(1-13W)W/EMERGENCY BALLAST.WITH 3. LIST TONNAGE OF EACH UNIT. 9. DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE CYLINDER 3. ALL METAL SURFACES WITH VISIBLE SOILING TO BE WIPED WITH APPROPRIATE THINNER TO CLEAN. ADAPTER FOR SLOPED CEILING. 4. SPACKLE ANY IMPERFECTIONS IN SURFACE WITH EXTERIOR SPACKLE,SPOT PRIME PRIOR TO INSTALLATION WAREHOUSE LIGHTING 20-013C "C'KEYWAY;SOLID BRASS;WiTH ADAMS-RITE CAM AND COMPRESSION RiNG 1 1/8"LENGTH WITH HVAC- DESIGN PROCEDURE OF FINISH COATS. HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING STANDARD. 5. CAULK SEAMS AT JUNCTION OF ADJOINING SURFACES WHERE OPENINGS ARE VISIBLE TO THE EYE. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DESIGN STANDARDS LISTED BELOW. 10. PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP 1. RUDD LIGHTING,TWO LAMP,54W,TSHO FLUORESCENT 277V.(H1A2X54-U4 2LMP 54W). MOUNTING HEIGHT AT 13'-4" 2. WOOD SURFACES I.E. SIDING,FASCIA BOARDS,SOFFITS, ETC: PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C. CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR REVIEW AND A.F.F. FINISH FOR AS NEW LOOK. a. RAW WOOD: APPROVALA FULL DESIGN SCHEMATIC FOR ALL UNITS IN THE TENANT SPACES INVOLVED.INCLUDE THE FOLLOWING: 00 ELECTRONIC DETECTION AND ALARM DRAWN BY: 11. TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. 28 30 O ALD 1. PRIME WITH EXTERIOR CONTROL PRIMER IF TO BE PAINTED. A. DUCTING AND SIZES 12. RETURN THE OVERHEAD DOORS ABOVE THE CEILING TO USE AFTER THE STOREFRONT IS REMOVED.TUNE UP B. SUPPLY AND RETURN LOCATIONS AND CFM S GENERAL 2. PRIME WITH THINNED SOLID COLOR STAIN IF STAIN IS TO BE USED. ALL OVERHEAD DOORS AS NEEDED. C. ROOF EQUIPMENT,SIZES AND LOCATIONS " DATE: 5/19/2009 3. PRIME WITH THINNED EXTERIOR ACRYLIC IF EXTERIOR ACRYLIC IS TO BE USED. D. UNITS REQUIRING DUCTED SMOKE DETECTION FOR HORN/STROBE DEVISES USE"SYSTEM SENSOR"SPECTRALERTADVANCE DEVISES,OR APPROVED EQUAL. 09 00 00 FINISHES b. PRIMED WOOD ANLD EXISTING FADED WOOD AREAS: E. THERMOSTAT LOCATIONS AND ZONE/UNITASSOCATED THEREWITH PERMIT SET F. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 32 00 00 EXTERIOR IMPROVEMENTS 1. APPLY FINISH OF MILLER'S ACRILITE TO TOTAL SURFACE TO ACHIEVE UNIFORM COVERAGE. GENERAL G. ZONE DIAGRAM 2. ANY NEW SIDING TO BE PRIMED PRIOR TO INSTALLATION. PRIOR TO ANY EXTERIOR EXCAVATION OR BORING,GENERAL CONTRACTOR SHALL OBTAIN AN UNDERGROUND UTILITY 1. CLEAN,SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. c. WOOD TRIM: HVAC DESIGN STANDARDS LOCATE. 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: 1. ROUGH WOOD TRIM TO BE PRIMED AND FINISHED WITH MILLER'S ACRILITE. THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: a. FLOOR COVERINGS AND BASE 2. SMOOTH WOOD TRIM TO BE PRIMED WITH ALKYD OIL PRIMER AND FINISHED WITH SEMI-GLOSS ACRYLIC. 1. 350 SQUARE FOOT PER TON. I b. PLASTIC LAMINATES 3. METAL SURFACES I.E. SIDING, ROOFING, DOORS, FRAMES,GUTTERS, ELECTRICAL PANEL COVERS, ETC: C. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE. 0 d. PAINT COLORS a. FERROUS METALS: A. EXTERIOR EXPOSURE AREAS e. HARDWARE 1. NEW-PRIME WITH ALKYD OIL PRIMER, FINISH WITH EXTERIOR ACRYLIC TO ACHIEVE UNIFORM COVERAGE. B. INTERIOR AREAS,SIZE AND USE 3. RESILIENT FLOORING SHALL EXTEND UNDER ALL NEW CASEWORK. 2. EXISTING-SPOT PRIME RAW AREAS WITH ALKYD OIL PRIMER AND FINISH WITH SEMI-GLOSS ACRYLIC TO C. CONFERENCE/TRAINING ROOMS ACHIEVE UNIFORM COVERAGE. N N # 225 �� TEId/ "�L i EROSIA y I RTLAND, OREGON . TENANT IMPROVEMENT FOR 3 SPEC SPACE VACANCY UPGRADES OF 0 16588, 16592 &16596 S.W. 72ND AVENUE TIGARD OR 97224 PROJECT #09200 PROJECT NARATIVE: THIS PROJECT THIS PROJECT IS A TENANT IMPROVEMENT REMODEL TO (7 iNTRSTy.e 6 UPDATE VACANCY SPACE IN ORDER TO ATTRACT A NEW TENANT 0 4 Qo HIM, )IIIII(IIII a (123) I , ,m, ;„ Q o to 8A WORK INCLUDED BUT PERFORMED UNDER SEPARATE PERMIT * '�, , ,,, ALE (121 M (122) / .(124) " PLUMBING a YYY Al .".•••;.,, ��� HEATING, VENTILATION AND AIR CONDITIONING U a. U I I FIRE SPRINKLERS Q LAKE 3 ""-• 1 = OS EGO ELECTRICAL INCLUDING LOW VOLTAGE (PHONE &DATA) L 0 %GO ' (118) 7 (110) - EXIT#290 Q Q� , is- - (116) Leo _ 2 (126 DRAWING INDEX J u)°~' ooInn•tnsIC( (108) I 01,13) ]- A-0 MAPS, PROJECT INFORMATION -^� Q co f i I L — ' .,r, I - ' r A-1 DEMOLITION - FLOOR PLAN —+ - �' - ,III �� - 1 6 N D N N nuirnuniril = (127) A-2 DEMOLITION - REFLECTED CEILING PLAN "-Z CO(O p r E18 1 (105) 1 I 0 1 M 811�q ; 5 DETAILS AND SCHEDULES w d d �ii��ni�iiiiw,iii,iiniiiiuuiinnn I fliniuIIIIII III ] "''"„'.'uc�� [j' ' A-6 SPECIFICATIONS v, AVENUE t ' � � SW 72nd AVENUE ) i BUILDING INFORMATION w BUILDING OWNER: PACIFIC REALTY ASSOCIATES, L.P. ❑ 15350 SW SEQUOIA PKWY #300 El PORTLAND, ORE 97224 Ill (503) 624-6300 (PHONE) Q N O EL 1 SITE PLAN - VICINITY MAP (503) 624-7755(FAX) m 4; A-0 SCALE 1 ” = 250' - 0" BLDG. #: OREGON BUSINESS PARK 1 V a a BLDG. 11 (PTR #124) CONST. TYPE.: TYPE II-B 0_ ; W 16580 16588 16592 16596 16598 / / / / / / STORIES: 1 Z_❑ NO WORK NO WORK Ii TOTAL BUILDING AREA: 2,237 sF OFFICE >mml u 13911111 1111111er Ir 1 Mt - 'IV all 3,907 AUTO REPAIR GARAGE 5 U :l■■■■■■■ !!!! ; : :<;>.►!/, i,...:�: :i:': ':: ::;!!'�l�:: t:;: 11,070sf WAREHOUSE r , ■ V , IL :.:. :-.�..1�■��■.�.��!!!!!♦�;.:......_.. ♦ ♦1.:? :... ...:5: i +l•�+l• ':...:...:: 17,208 sf TOTAL B"' 1■■■■■■■1!!!! '!i�! �l4 4 ALLOWABLE AREA: B - 23,0005 ` > (fable 503) S1 - 17,500 sf v.v. ..Las S2 - 26,000 sf 1 IM ENIMIN■iii !!!!!!! I sal l l l� !!! v 4.••••■•■�••••••����1 11+++l+l++l�l• +1r lir-∎ '++l+l+l•�+!!+!!!/ THIS IS A ONE STORY BUILDING WITH 'B', 'S-1'AND 'S-2' .�.��::�rdi���n CC•!!!!!+!!!+!!!+�l+l+l+!!!!!!l+l+�,l+!!!♦� FRONTAGE OCCUPANCIES, ON THE OFOURTH SIDES 55SIDE5 EXCEEDS 60', : EM••••C•i..h : :::�::::!!!!!ll ::::;!!!!!!; BUILDING HAS AN AUTOMATIC SPRINKLER SYSTEM THROUGHOUT■OM w NON-SEPARATED USES: BUILDING IS A MIXED OCCUPANCY, NON-SEPARATED USES .■■■■■■:.....■■■I�!!!!!+!+!+!!!!��!!!!!!!!+!!++!!4►!!!!!!� (302.3.1) 1.11.11.........11111 i!!!!!!!!!♦ ♦!!!�'!!!♦ ■■■IIMM ■■ ■■ �1•�∎ a a a.4. A. 4. . 6. . ...�. ......4is A. A.../ OCCUPANT LOAD: 16588 >al (TABLE 1004.12) B = 359 sf/100 = 4 Q S2 = 4,560 sf/500 = 10 CITY OF TIGARD N TOTAL OCC LOAD = 14 - 1 EXIT REQIRED (TABLE 1019.2) Approved I� Conditionally Approved [ I r n 2 OCCUPANCY GROUP PLAN 16592 seeIetterto:fl° A-Q SCALE 1/64" = 1' - 0" Aft:B = 367 sf/100 = 4 (A N S2 = 862 sf/500 = 2 Permit Ni sb. • • 0 i• ��S•r U MW t8 f� TOTAL OCC LOAD = 6 - 1 EXIT REQIRED (TABLE 1019.2) Add s5: �� )I W Lo to By: ;Parsec Date: 'af' ifs r W Z r Q 16596 N 0 B = 316sf/100 = 4 . � mtoO S2 = 3,371 sf/500 = 7 Pfm� e ' O c ^ Z (DZ ri TOTAL OCC LOAD = 11 - 1 EXIT REQIRED (TABLE 1019.2) FlreMarat ..^.. W v /1 0 r Mechanhat „I`� d W f EC Plumbing . l;_ C,) CO O to O Electrical .. ,'Ilr Et PLUMBING FIXT REQ'D: (1) WC& (1) LAV PER TENANT SPACE Truax Etlylneerh ,.... , • (2902.3 EXCEPTIONS) ShopDmwhl0e ..,4.. REVISIONS Other .,.,,• O-T-C 1 Oeeup ncy1 pa - 2. TENANT INFORMATION Oaaupaney[oad H 3. Construction Type TENANT: ALL SPACES ARE SPEC SPACES - NO CURRENT TENANT ga�CorfldOr 4. • Energy Coda 5. Accessibility 6. OFFICE COPY DRAWN BY: ALD DATE: 5/19/2009 PERMIT SET A ..... 0 ..13 illt$1.:,fr C 25 � A' MU'j DEROSIA C , 8 1 0o DEMO - KEY NOTES THIS SHEET J y •7 6 4 • o,o 1 SPORT D, OREGON* OREMOVE CARPET&ADHESIVE _ I fI �L' «---- 7 BAYS AT 241-7" 1 7 2 -1 1 2 REMOVE VCT&ADHESIVE QF O I 1 O--- C 1 O REMOVE VINYL FLOORING&ADHESIVE PROJECT #09200 1 I I 1 // I REMOVE PLUMBING FIXTURE(S)AND CAP LINES I :F::5 REMOVE WALL(S) U 1 I e _ _ w 6 REMOVE RELIGHTS) Q O'1 0 1...____ ______I 1 ,I L. L_____ ______, --3 ..I.. . I 0 I I I I 7 REMOVE DOOR(S)-REUSE 3070 DOORS ONLY I w 1 (IF SALVAGABLE) 0 < CO < Immoro I 17 I 16 1 T911-11 16 (n 0 18 0 8 REMOVE CABINETS)= o 0 O a.< cii:: 1 o 1III REMOVE STOREFRONT o l WD e 10 REMOVE STEEL STAIR&AWNING ® E CD N 1 \ 0 1 (7-T 0 I I O I I II 7 ` , 7 ,I 11 REMOVE PLYWOOD MOUNTING BOARD _J ?>1` O LO t� it @:: 12 REMOVE SURFACE MOUNTED CONDUITS AND BOXES` Or-R O CO o , 5 O D I I I �� I � ,0 ( 1 _ NIA NN 13 '-_-�, I 13 REMOVE SURFACE MOUNTED PIPES AND EQUIP T O a) 0 O 8 -- _ O 1 0 -f _ -1 I- e,I 1 - - , p� ^^ I i r,--;I `�_/ (°1 - 0 1 , 4 I , 14 O ____ z,, O I, REMOVE ALL ELECTRICAL,COMPUTER AND O O L_.1 �, ��, mow, _1, Ln n e LO 8 , , TELEPHONE BOXES FROM DEMISING WALLS 0 III 3 . 0 3 0 0 _— 0 0 7 U DI it) Z X __ Ii „ �, u__11: , o ( NLESS IN CATED TO REMAIN) < I I i: = II, 0 /-i - 1-1- I 7 12 5 = I 0 15 REMOVE CARD READER 410 7 / O I R I - '-\\\ 8 14 _ I I , 5 I 1 I ::iII 16 REMOVE MINI BLINDS O o AI __,14 I 17 (E)MINI-BLINDS TO REMAIN I I O I I 0 oc w @:: ' O 0 O 18 (E)EPDXY FLOOR TO REMAIN. .. @i: CC T 0 I , I I I 1 0 1- 9.__. a I 10 1 I I , GENERAL NOTES El.EXISTI ENANT , EXISTI TENANT 14-k - - - - - _ ' - - - - - - - - - C - - - - IOC - - - - —Oc , D SPACE cam- - q _� o ' fin ° 11 , 1. REMOVE ALL DATA CABLES LEFT BY PREVIOUS (� 3 i NO Wei" I I L I I NO WS 5 o F= 12 5 TENANTS. LEAVE PULL STRINGS. Z 0 5 7 I 17 0 EI:: O 5 1 o o, II , o _J I- i _i, ►-' 2. WALL TEXTURE: SOME OF THE(E)WALLS ARE 5 0 I I II \ , it I . i I I 11 1� Il // TEXTURED. THE TEXTURE IS Tco( REMAIN. NEW m ( Ij WALLS WILL BE SMOOTH FINISH. Co)O a. L � I @1I:: EI:: I I I I O 01 0 I I I I I I , 0 O /7® I I I, II 1 I 1 1 1 0 0 ® 12 ALTERNATE # 1 : n „„...._< ...-• . I 0 0 0 1 ::9 I® o PROVIDE ALTERNATE BID TO DIAMOND GRIND THE , WAREHOUSE FLOORS TO REMOVE THE MASTIC Li] I 14 1 o i 7 1 , , DOWN TO THE CONCRETE. AFTER GRINDING,SEAL O L— THE FLOOR WITH AN ACRLYIC SEALER. 0 O18 LL1 > I I I ® I 1 1 COMMERCIAL FLOORING REMOVAL Q 0 21950 S.LANCE CT. 0 OO BEAVERCREEK OR 97004 - Z I I 1 =I (503)632-2246 Y o o CLYDE FREED _ ®// o_ (I) it I 10/J I I O. Zoe 1 5 _ r Mc s. o I I I I - 0,... ao � o 79 z CO Z 44 (f)Di co .:ii 0 0 0..., ,A p 1 II ,.., LiIUi1 �� 11 ,_ � I I II O , a REVISIONS 1 . 1 2. 3. N 4. DEMOLITION - PLAN 1 SCALE 1 8 = 1' - 0” 6. Al � DRAWN BY: ALD DATE: 5/19/2009 PERMIT SET II C„N( .1°D r ARTEMU 0 EROSIA r1 CEILING DEMO - KEY NOTES THIS SHEET • ORTLAND• • OREGON 8 E3II: O30 REMOVE CEILING GRID,TILES,LIGHT FIXTURES, DIFFUSERS,ETC. 1,Z) lr of I 0.$ 7 BAYS AT 241-7'I _- 1721-1 II I I 31 REMOVE LIGHT FIXTURE O32 REMOVE CEILING GRID IN VESTIBULE>- PROJECT #09200 I I i I I i 33 A, --- U 0 16582 I ' 16580 0 16586 16588 16592 16596 16598 Q o l 1 2_ CC) I I I r 1 A I I I { I I I I I I I I I I I I I \ - -� ----J I I p I -- �I I I I u- -,,,- , , tt tt u -I---- -• i i I I II T-� i I----i--1--J . h1- -- I i• I • \ I T h �c T- ---I • i 0 I I ` I 1 1\ 1 II i -1 ,-r=1--fi--r--i=-,r--r- -=r I \ i 1 I i -7 -- --r---1--I--r 1 i-- �c_--1--c=�---- Q � �� (-'--1- ,wry r �- rt�- � � � l' I�-� i ► I \ I II \ I \ I \ I \ r I I I � I CIE I 1 1 1 II II I i 1\ 1 1\ # 1\ 1 • 1\ II I\ I I\ O \ I I \ I \ \ I I \ I I I �( I i I I 1 \\ IF-�1 1 \\ II 14 N11 \ ' '-_�1 ) 1_ # 1 _ _ 1 \\ 1 I \\ t 1 \\ 1 1 \ 11 I \ 11 i \ I I I i L I �q,. - i \ I I \ I \ I 1 \ • \ I I , +--I--� --V---)I-- 1 �- \ \ nil I \II I I \II I \I I I JgI I II 11 11 I I I I 1 I , r� 30 �� i I I I 1 ' r I--Tim-�i- -1 t wl- i f-- i I--hI I (1 ' CO N 1 1 1 I rl i i / 1 ic_y , r': �': I -r -IN- IC--=,i__rt1 11- \>L__4___---1--_1 1 1 I I �I IIi I I i � N I I • I I\ II • II\ I I 'x111 \ I i �}� �7 I 11 III I I o LO -- --- _ _J_ I \ II II \ I 1 1 -f----I-. 1- --•-1----1 I YY Y - --L- I� �I ill 1----fr=4---F==,1--+- � 0t I I I 1 L --- 1 I _ � ___ r r � I I � - 1 I -I T I- -I T - - _ �- � I\ I • I\ I V J I I I I I r-� 1 \ 1 1 \ 1 I \ I I III I I i Ir ^ 11 1 I \ I I I i II \ 11 1 \ 1 -��-y�IG_]IL__ J. I Ii i I I I I I If\ I I \ I I I I 1 I1 \ II I \ I � O I I I \ I I \ I I \ I - r=- , T __-=J _ __ _ I I I I _ I\ I \ \ • I \{ I , r'i1 I T r }t T� ,i- -I • . I { I I I I II \II I \I I I I - I I f l I I I I II \If 1_1_ L-� L-� N L_�I L_J' I I I i II\ II I �11----�---i- --a--->- �__� N9 N --H-IL-----.4t- t r 1 r �� I { I I I \ I I i 1-11- I I I I I 1 I i r co l l l = ==C=1 -1==� L 1 1- 1 iL-�I1 �- i ii \y i Oi i:!:! dS (6.: I I 1 i I I I +-- '- TI- 1�- ,+---I r� t i ®11 \1 CD { _ 1�I� - -- f - -- - 01- o ----I-1-=-1--1 --i-- __i_1_--I-- !__ 1�y• 1 AC? #2225 ARTEM k L DEROSIA CI r y 0 E?_1 3 2 1 ; FLOOR PLAN — KEY NOTES THIS SHEET . 8 7 6 ' I'T ), OREGON e.�j, 0 1 q2)/ (N)WALL TO STRUCTURE PER DETAIL 3 ON SHEET A 5 '4" OF 6' . 1 II � I ll I 2 O (N)WALL PER DETAIL 2 ON SHEET A-5A 7 BAYS AT 24'-7€..4„i,,,::,,, 172 1 3 ALIGN PROJECT #09200 _I O► I 4 REPAIR SURFACES AT REMOVED WALL --'o O 0 0 o EXTEND GYPSUM BOARD TO STRUCTURE 0 1 16582 16596 T R LL UP DOORS TO WORKING CONDITION.16592 16598 RETURN HE E O 6 1 5 6 16588 c )16580 � 6 8 � � — o�i � O CI C o i I��� -� ��.� PROVIDE A NEW STEEL TUBE POST BETWEEN THE DOORS.kk k 0 f C'7� ENTRY ENTRY ENTRY � ENTRY <C 1 1Q8A `.. I 1 PROVIDE NEW WEATHER STRIPPING AND A NEW BOTTOM SEAL i o> 102 101 121 141 Q i�- , 7 PROVIDE NEW MINI BLINDS AT EXTERIQR WINDOWS ir r- i�� ► o C102 101> © I Ci21� oFFicE I © W s /© 1 Q 8 (N)4 x4 WALKOFFMAT O Q <1 1 122 1 0► f�'1 AgC 1 U—_. O i 1 O _4 I = I I g INFILL TOP OF WALL TO MA L LEVEL w D OFFICE 4 © -T I LET OFFICE 1 o ® wd' i o O 1 R TURN THEE ROLL-UP DOORS TO WORKING CONDITION. Cl)N► - 10■ E 103 , 1 00 CV 142 0 i t'33 I_ 125 I I 1 r I I\ PROVIDE NEW WEATHER STRIPPING AND A NEW BOTTOM SEAL. p►103 1 �1 /t t�O ► 1 <1 ► LL ~,1 V J/ ► _ o (U RE FEE D 3 EXISTING RECEPTACLES BY ADDING A JUNCTION G� • ; 1i 26 � i 11 O D C4� � i 1 \ I ► I o BOX ABOVE THE EXISTING GYPSUM BOARD TO INTERCEPT THE - d"d- I.�. , 1 (V CV O (V► O 1- O 1 ► LINE. r Z (O C4 - 0 142 p BREAK RM 1 .• w as 1 c�(�r)© 1�1- 104 1 r� 4 1 F.E. ® rC� ©_ 12 ROUGH-IN FOR FUTURE W.C. H O E- L°° 11 �� . � � � ai °° TOILET � n O =L� i SI K TO ACCOMODATE FUTURE LAVATORY® � � _ 13 ROUGH IN N Q T� ��� 124 ;'� 143 O�1 k..•� ELECT .�I,TOILET I I FI E ,• OF C �.105 k— i 124 '10 ice'© 00 0 ;» ® � = 123 i o0 1 721 144 6 GENERAL NOTES LIU )0- 1: P. ► tf)\- 7'-4° \ I LET 1. AT INTERIOR SPACES, PAINT ALL SURFACES E 1 © EXCEPT FLOORS,LAY-IN CEILINGS AND I ELE T ,� © 1 144 C 8 6 rr ■ WAREHOUSE INSIDE THE ELECTRICAL CLOSETS. AT THE �S 'r 107 �� L �' T 126 EXTERIOR, PAINT ALL SURFACES INSIDE N L C T-THE ENTRY ALCOVES AND THE OVERHEAD 0 CC I C[.I' 106 I DOORS ONLY.'� 106 f-107 11 2. PATCH THE GYPSUM WALLBOARD AT ALL 1 I I � REMOVED ELECTRICAL,COMPUTER AND T e. EXISTI 1 TENANT T—EXISTI E NANT TELEPHONE BOXES.BLEND PATCH INTO � B — — — — — — — PACE — — — —o — — — — — - - — — --OCC- - I EXISTING WALL FINISH.NO WO- ' 1 1 I NOW• K a Z 3. PROVIDE NEW ROOF-TOP HAVC UNITS TO J WAREHOUSE WAREHOUSE o SERVE 16588 AND 16596. PROVIDE NEW 5 fJ I I 108 145 DUCT WORK AND GRILLS. m, 0.. z I 4 I ,. I 1 FLOOR PLAN LEGEND 0 i I I , EXISTING WALL TO REMAIN o- I I © I 1 I I NEW WALL o O d EXISTING DATA/TELEPHONE TO REMAIN Lll O .gt , I I 011 I , I I EXISTING ELECTRICAL RECEPTACLE TO REMAIN 0 w- , I -1 NEW DATA/TELEPHONE Q a z lgt NEW ELECTRICAL RECEPTACLE(DUPLEX) I I I _ NN SURFACE MOUNTED FIRE EXTINGUISHER < ,d. F.E. CV I I I I 0 WEB Ill Z � cr ENO I O @k O IO Alliallk 1 p Z c.0 1080 (_,� r V H r 1 H ;RECW°SIOCCN:000 A w a0 1 cc O rn o o_ 1 . 1 2. 1 A ALTERNATE # 2: 3. NPROVIDE AN ALTERNATE BID TO REPLACE THE 4. 1 FI_OOR P LA N NEW BASEBOARD HEATING SYSTEM IN 16592 WITH A NEW ROOF TOP HVAC SYSTEM. REMOVE THE 5. 6. A3 SCALE 1/8 = 1' — 0" BASEBOARD HEAT. o ALTERNATE # 3: PROVIDE AN ALTERNATE PRICE TO EXTEND THE DRAWN BY: GYPSUM BOARD TO STRUCTURE AT THE DEMISING ING ALD WALLS ON GRID LINES 3, 4 AND 5 ON THE WAREHOUSE 108 AND 145 SIDES SIMILAR TO KEY DATE: 5/19/2009 NOTE#5. DO NOT INCLUDE THE INTERIOR OF PERMIT SET WAREHOUSE 126. o,,`c°3 illib., 225 ' ARTEM Ca 8 i DEROSIA C 8 A ti 7 6 • 4 2 .., t RTLAND, OREGON,. i 1 LI 7 BAYS AT 24 I-7l v 172 -1 i I OF 6c I I PROJECT # 09200 I I 1 I I I (l) I I GENERAL NOTES A o ' 16582 I ' RE-ATTACH SAGGING SOFFIT PANEL A ' ' .. _ - 16580 16586 16588 / 16592 16596 15598 1. [N-FILL ROOF AT REMOVED HVAC UNITS AND Q r i u ter_ r r Q i 1 . , -- O \ RESTORE ROOFING ‹... O I I 0 I ° I 0 I 0 I 2. PROVIDE WIRE SUPPORT OF BATT INSULATION 1 ® ® , 0 UNDER ROOF THROUGH OUT-PATCH AND REPAIR I O 1 I INSULATION AS REQUIRED r n 0.. BATTERY Cl) �/ _ I a �� BACK-UP ' 1><- 3. SERVICE THE UNIT HEATERS IN THE 0 I I 1, \ I $ ■ I I WAREHOUSE AND RETURN THEM TO WORKING BATTERY 1 • H CONDITION. PROVIDE NEW THERMOSTATS FOR ® 0 NI- BACK-UP EACH. (o N I 1 I I I _I O LO �''__t ; ><- 4. INSTALL WAREHOUSE LIGHT FIXTURES AT 15 AFF Cl)O O t _ I i I CU I ® • 0 I I 5. REMOVE THE SPRIKNLER DROPS IN THE O d' ---) N. N N o b) co :! LP WAREHOUSES. MAINTAIN THE REMAINING"UP" �'. T Z O O _ to 1 -Q- SPRINKLER HEADS AND MODIFY THEM AS NEEDED W off RR I I I I I .I I Cc I TO PROTECT THE WAREHOUSE AND MEET CODE. t-- o f 80L. 1—____,, 6. AT ROOMS 122 AND 123,TUNE UP CEILING GRID r O.. a u I I I I b • I I AND REPLACE BROKEN TILES WITH SALVAGED TILE •DID FROM OTHER SPACES.PATCH IN GRID WITH i • SALVAGED GRID FROM OTHER SPACES. I T r pi I ,1 STEADY BURN WITH I >I BATTERY BACK-UP 0 1 • 7. PROVIDE 2x4 FLUORSCENT SURFACE MOUNTED IMM WRAP AROUND FIXTURE IN BREAK ROOM 104. 0 a I Eli I I I LITHONIA LB 2 32 MVOLT GEB10IS E ais 1 LE 7 33 0 < N cc I m 0 }- n I EXISTI I ENANT I ' I I I f 9 EXISTI i TENANT I; to ( B ) - - - - - - OCCU' D, .PACE— - - - -0,----- - - — — - - - - - - - a SP AC':E NO W. I 1 STEADY BURN WITH i I I NO W• "K O 3 BATTERY BACK-UP _Z O -J I I I I I I 5 0 F" 0 m (0 z 41: I I E I 1l 1 I I BATTERY BACK-UP 1 I I 0 I I ' I Ii \ I I 6 I SYMBOLS- REFLECTED CEILING PLAN: ,„,...„_< O /I I I EQUAL EQUAL EQUAL EQUAL c9 �- _ po ' I \ 1 (E) LIGHT FIXTURE TO BE REMOVED N 1 \ I I 1 (9 I I 1 t_ W �_ (N) 18 CELL PARABOLIC LIGHT FIXTURE I 1 I I I I A Q a. . _ z RI I I BATTERY I I I I 0 W Y r.. BACK-UP 5 ° EQUAL / EQUAL I I EQUAL EQUAL I X EXISTING SUPPLY AIR DIFFUSER CO N i ZO OC s ill EXI TING RETURN AIR GRILL 0 0 � — , I I I 1'- I T 1--111- ----.) I j N O m Lo o Ae-ii r A ,, ® EXISTING FIRE SPRINKLER HEAD 0 Z co Z 44 (f) V a0 ® NEW OR RELOCATED EXIT LIGHT a LO o vs O r- °- REV'S ION S RUUD H1A2X54-U4 2 LMP 54W 1 . 2. 2 3. N 4. 1 REFLECTEDCEILINGPLAN - NEW 5. A2 6. SCALE 1/8 = 1' - 0" DRAWN BY: ALD DATE: 5/19/2009 PERMIT SET MM. A FLOOR AND/OR ROOM STRUCTURE ABOVE ARMSTRONG BERC2 CLIP (AS ALTERNATE MEANS OF CONSTRUCTION FOR THIS PROJECT) (/) -: ` ., CC \ ��, � 5/8 PLYWOOD DECK OVER TOILET ROOM g� BLDG. STRUCTURE ABOVE 21_011 0 ADDITIONAL HANGERS AT ALL MAINS CT Wesio.-4 � 0/ 2225 WITHIN 8"OF THE PERIMETER s > DEFLECTION CHANNEL O ARTEM !, L DEROSIA APPROVED VERTICAL STRUT AT 12'-0"O.C. EA. WAY - - - a ATTACH JOISTS TO END TRACK WITH 10 X $ a�� C O — 1_3 WITH 4 WAY LATERAL BRACING FROM THE MAIN _ I SCREW EACH SIDE OF EACH JOIST I _ " J • ,� • n RUNNER TO THE STRUCTURE OVER. BEGIN WITHIN 6'-0" 8" 16 GA MTL. JOISTS @ 16"O.C. CAULKING iN 1/2 SPACE U D, OREGON, 4- OF THE PERIMETER AND 2" FROM A CROSS MEMBER it — RELIGHT KIT WHERE SPECIFIED ._.���..ri-_:, LOCATE DIRECTLY OVER STUDS - R-11 BATT INSULATION ro O N N i SUSPENDED CEILING \ 6 6 O SUSPENDED CEILING \ Z I \ �F " 6" FIBERGLASS INSULATION J s..,y 5/8 GYP BD (J` O ' •0 ; — �� 3 5/8 25 GA MTL. STUDS @ 16 O.C. - w C_-� 6" MTL. STUDS 24"O.C. Z PROJECT #09200 i ;,'c r� ATTACH STUD TO TRAK WITH (2) 7 x 16 - 0 OC = ,3 D \-- " SCREWS (ONE EACH SIDE) BOTH ENDS ` I O a co - 5/8"GYPSUM BOARD w � 5/8"TYPE GYPSUM BOARD U w w N ADDITIONAL SWITCH .� } F- i BOTH SIDES SCREW ATTACHED o 0 GANG LOCATION O U) .--[8" SECURE ALL HANGERS TO BLDG. �� f - CENTER LINE OF STUD 0 z C--'� _ w U " I \- Z U MAX STRUCTURE OR A TRAPEZE FOR I� O CENTER LINE OF STUD O 0 \ \ 5 I- DUCT AND/OR PIPE WORK 11 - 3-1 3-1/2" FIBERGLASS INSULATION 0 w z /5"/ < `w .. 5/8 W.R. GYP BD Z I- a ►� _ }- U 6'-0"MAX CROSS MEMBERS BETWEEN N = 0 tr R-11 BATE'INSULATION = 0 \ _ O Q O ` MAIN RUNNERS o 4 RUBBER BASE-TYP. ° O _ O _f MAIN RUNNERS AT 4'-0"O.C. " ATTACH STUD TO TRACK WITH w -' ill 4"RUBBER BASE TYP. w0 EL CTRICAL w % r SUPPORT WITH #12 WIRE AT 4-0 O.C. w LL E > w Z OR WITH #10 WIRE AT 5'-0"O.C. :1111.11. 10 x s SCREW EACH SIDE OF STUD Z Z LL ©R J BOX -J Z I- a Q 6" RUBBER BASE D 0 � ATTACH BOTTOM TRACK TO FLOOR WITH O o O �n COUNTERSLOPE HANGERS lF MORE \ ATTACH BOTTOM TRACK TO FLOOR WITH POWDER DRIVEN ANCHORS AT 12"O.C. 0 0 b I- vJ THAN 1:6 OUT OF PLUMB O� POWDER DRIVEN ANCHORS AT 12"O.C. \ I - ❑ \ 0 o E Or� FINISH FLOOR-TOP OF SLAB / FINISH FLOOR _\ UNDERCUT I eOR AS d' b 0 Q NOTE: ALL CONNECTION DEVICES TO BE IBC FINISH FLOOR - REQUIRFIDlT�� .EAR O �-- '� -_�_.-__v_.___.. ' . .._. -_ .::� � FLOOR FINIS � APPROVED TYPE AND HAVE 100# CAPACITY '- W D RESTROOM SIDE OFFICE SIDE WAREHOUSE OFFICE 0 w 1- (o N 1 CEILING BRACING SECTION 2 SECTION - TOILET ROOM WALL 3 STRUCTURE HEIGHT WALL 4 MOUNTING HEIGHTS -J (D o� 11 _ 1 _ �� �� _ , _ 0" .1 _ 1 _ II �a of A5 NOT TO SCALE A5 SCALE 1 = 1 0 A5 SCALE 1 = 1 0 A5 SCALE 1/2 - 1 0 U) D 00 O CC N •;j- EN Z C N OC W dS'c RF) O 2° R 2° LO� �� 34 / 331 . iM o _ Q -fl o_EL 1'-0' 31_6■ / / / MICRO SHELF AT \ \ __ __ __ __ 18"DEEP WITH 2' ED ��i / \ AD .S . \ 1 1 RADIOUS *- I I i _ 1 1r CORNERS — -- -- � a N co II- LLI ›- io LO• ) I RUN JOISTS 4ROR 36" OPEN BACK =OVER TOILET - / L__ ___I T- i7H\ - ,� ' ROOM IN THIS p \ \ _Fp 1 �; 1 DIRECTION a *- - USE USG FIBEROCK I-- PL BAC ASH N 0) C.P. F.D. ? ' CO N T— BRAND AQUA-TOUGH �. 0 \ , ! h r ��� _ (00 INTERIOR PANEL(5/8') 1 I_ ), ; ' Cr ao -" _ �o ," o I _ FOR LOWER FOUR FEET _ t _ 1- i 4 ADA WALL `� OF THIS WALL AND t ( > 0.. 0. ' ,g; .,� cg r HUNG SINK i / Cl 1 53 PLUMBING WALL-USE j N / 1 `� \ \ _ \ \ \ \ I \ \ \ \ \ T GREEN BOARD FOR ? I T iii. 10 6"RUBBER BASE REMAINDER OF ROOM 311 1R t- / / 2°4 2121 114° 33" l2 1 R / / 3 D 0 3 -0 / / 68° / QZ 1 J 6 ENLARGED TOILET RM PLAN -� TOILET AM ELEVATIONS 8 BREAK COUNTER - 5 A5 SCALE 1/4 = 1' - 0" A5 SCALE 1/4 = 1' - 0" A5 SCALE 1/4 = 1' - 0" m I 0 5 4 I IL 1 41 R z OOM FINISH SCHEDULE I WALLS RM# NAME FLR BASE CEILING CLG. REMARKS 0 NORTH EAST SOUTH WEST HT. )R , )R 101 ENTRY (E)CONC NA CONC-PT/OPEN (E)THB-PT WD WDW WALL-STAIN/THB-PT (E)THB- PT (E) PLYWOOD- PT 9'-0' RE-FINISH WDW WALL 102 ENTRY (E)CONC NA CONC-PT/OPEN (E)THB-PT WD WDW WALL-STAIN/THB-PT (E)THB- PT (E) PLYWOOD- PT 9'-0' RE-FINISH WDW WALL 103 OFFICE CPT-1 RB WOOD STOREFRONT (N)G.B./PT-1 (N)G.B./PT-2 (E)G.B./PT-1 (N)S.A.C. _9'-0' RE-FINISH WDW WALL 104 BREAK RN! SV RB-1 (N)G.B./PT-1 (N)G.B./PT-1 (N)G.B./PT-1 (E)G.B./PT-2 (N)G.B./PT-1 9'-0" -- 105 TOILET SV 6'RB (N)G.B./PT-1 (N)G.B./PT-1 (N)G.B./PT-1 &FBRK/PT-1 (N)G.B./PT-1 &FBRK/PT-1 (N)G.B./PT-1 9'-0' -- 106 ELECT (E)CONC (N)G.B. (E)G.B. (E)G.B. (E)G.B. -- 9'-0' -- \ LjJ o __ t ) J >- � 3 I - .107 ELECT (E)VCT (E)G.B. (E)G.B. (E)G.B. (E)G.B. -- 9'-0' -- 0o J I 00 a g -- 00 0 0 e 108 WAREHOUSE CONC. RB @ G.B. CONC-G.B./PT-3 (N)&(E)G.B./PT-3 CONC - _ (N)&(E)G.B.-PT-3 0.T.S. - 9'-0° RE-FINISH WDW WALL w Nt Q 0 N. Q XX 121 ENTRY (E)CONC NA CONC PT/OPEN (E)THB PT WD WDW WALL STAIN/THB-PT (E)THB PT (E) PLYWOOD PT 9-0 RE-FINISH WDW WALL Q Q )R 122 OFFICE CPT-1 RB WOOD WOW WALL G.B. G.B. w CO J - - 0 (E) (E) (E)G.B. S.A.C. $'-2" RE-FINISH WDW WALL Q c� o a 123 OFFICE CPT-1 RB (E)G.B./PT-1 _(E)G.B./PT-1 (E)G.B./PT-1 _(E)G.B./PT-1 (E)S.A.C. 8'-2" -- 1 \ \a \a \ \ _ 1124 ELECT CPT-1 RB (E)G.B./PT-1 (E)G.B./PT-1 (E)G.B./PT-1 (E) G.B./PT-1 (E)S.A.C. 8'-2" -- — N 9 SOAP PAPER SAN. NAP. PAPER RECESSED SEAT COVER TOIL. PAPER/ GRAB BAR MIRROR 125 TOILET SV 6'RB (E)G.B./PT-1 (E)G.B./PT-1 (E)G.B./PT-1 (E)G.B./PT-1 (E)G.B./PT-1 8'-2" -- W . I; DISPENSER TOWEL DISPENSER TOWEL TOWEL DISPENSER SEAT COV. DISP./ 126 WAREHOUSE CONC RB @ G.B. G.B./PT-3&CONC G.B./PT3&WD/PT-3 WOOD/PT-3 WOOD/PT-3 O.T.S. 9'-0' -- < DISPENSER DISPENSER DISPENSER SAN. NAP. W Un 't RECEIVER DISPOSAL )R 141 ENTRY (E)CONC NA CONC-PT/OPEN (E)THB- PT WD WDW WALL-STAIN/THB-PT (E)THB- PT (E) PLYWOOD- PT 9'-0° RE-FINISH WDW WALL N U7CO N 142 OFFICE OPT-1 4 1 RF _WOOD STOREFRONT (N)G.B./PT-1 (N)G.B./PT-2 (E)G.B./PT-1 (N)S.A.C. 9 1-0' RE-FINISH WDW WALL W 0 143 TOILET SV 6" RB (N)G.B./PT-1 &FBRK/PT-1 (N)G.B./PT-1 (N)G.B./PT-1 (N)G.B./PT-1 &FBRK/PT-1 (N)G.B./PT-1 9'-0' -- O z (II _ 144 B./PT-1 9'- ' --LET ROOM ACCESSORY MOUNTING HEIGHTS U7 O A5 SCALE 1/4° = 1' - 0" 145 WAREHOUSE CONC. RB @ G.B. {N)&(E)G.B./PT-3 (E)&(N)G.B. (E)G.B./PT-3 (N)&(E)G.B./PT-3 O.T.S. 9'-0' -- 3 N mLoo a O z xi Z w FINISH MATERIALS - (TAN SCHEME) CJ J O T w co CC SAMPLAES OF ALL FINISHES MUST BE SUBMITTED TO ARCHITECT PRIOR TO INSTALLATION. 'U W o0 CARPET LOOP PILE: 1 EN 53 g - CY) CPT-1 PATCRAFT 10147 FAMOUS LAST WORDS II, 47200 LOOK NO HANDS, DIRECT GLUE ABBREVIATIONS CONTACT FOR PACTRUST PRICING&ORDERING INFO:IVY RI 503- -682 NFO. O'BRIEN EN 754 6 ADJ ADJUSTABLE REVISIONS WALK OFF MAT I BLDG BUILDING VAN DIJK CONTRACT,#41,4'x 4' 1 CONC CONCRETE DOOR SCHEDULE SHEET VINYL CPT CARPET 2. 2 SV ARMSTRONG MEDINTECH,86412 OATMEAL, SEAMS NOT PERMITTED EXPOSED EDGES AT ( (E) EXISTING DOOR DATA FRAME DATA HARDWARE DOORS OR OPENINGS TO HAVE TRANSITION STRIPS-SUBMIT OPTIONS AND COLORS TO 3' E.T.R. EXISTING TO REMAIN Remarks Mark Door Size Thk Core Veneer Finish Hand Fire Rating Type Frame Depth Hardware Manufactu r er F ini sh Function ARCHITECT FOR APPROVAL GA GAU GE 4. 101 31-01 x 7-Q 1 3/4 SC WOOD STAIN LEFT WOOD 4 3/4 CONTACT FOR PACTRUST PRICING&ORDERING INFO:MARK JONES 503-201-3657 LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N) LOCK- RE-FINISH DOOR BASE G.B. GYPSUM BOARD 102 3'-0"x 7'-0° 1 3/4' SC WOOD STAIN RIGHT WOOD 4 3/4" LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N) LOCK- RE-FINISH DOOR 5' RF BURKE MERCER 4"FLAT RUBBER BASE,597 MOCHA AT ALL CARPET AREAS. GYP. BD. GYPSUM BOARD 103 3'-0'x 7'-0° 1 3/4° SC WOOD PAINT LEFT TIMELY 8 1/2' PASSAGE LATCH SCHALGE _613 AL1OS DOOR -(N) LATCH RC BURKE MERCER 4"COVE RUBBER BASE 597 MOCHA AT ALL HARD SURFACES 6. (E) � IBC INTERNATIONAL BUILDNG CODE 104 3'-0'x T-0" 1 3/4' SC OAK WATCO RIGHT TIMELY 4 7/8° CLOSER/PASSAGE LATCH SCHLAGE 613 AU OS -- EXCEPT USE 6"IN TOILET ROOMS. MAX MAXIMUM 105 3-01X 7-0 -1 3/4 -SC OAK WATCO LEFT TIMELY 4 7/81 PASSAGE LATCH SCHLAGE 613 L9486 OCCUPANCY INDICATOR MIN MINIMUM 1 x -0 106 2-fi 7 1 3/4 PAINT: SC WOOD PAINT RIGHT_ WOOD 4 7/8' E.T.R. E.T.R. E.T.R. E.T.R. DOOR& - E.T.R. PT-1 MILLER 4480 PREMIUM SATIN 8721W CLAY BEIGE, SATIN LATEX. MTL METAL 107 2'-6"x 7'-0' 1 3/4' SC WOOD PAINT LEFT WOOD 4 7/8" E.T.R. E.T.R. E.T.R. E.T.R. DOOR&HDWE- E.T.R. PT-2 MILLER 4480 PREMIUM SATIN 8724M MEADOWLARK,SATIN LATEX (ACCENT COLOR) (N) NEW 1 ■ 1 R ■ R .w 108A 3-0 x 7'-O" 1 3 4 SC WOOD PAINT RIGHT WOOD LOCK-CLOSER CHLAGE 13 N92PD DOOR(N) LOCK PT-3 MILLER 3780 PREMIUM FLAT-MIX IXX79W(WAREHOUSE WALLS - / S O 00 6 SCHLAGE 6 (E) ( ) O N� WALLS) NA NOT APPLICABLE DRAWN BY: ■ 1 ° " CONTACT FOR PACTRUST PRICING&ORDERING INFO:AMY TACKE 503-3484307 _ _ C N CT F R PA R R NF MY 108B 3 0 x 7 0 1 1 2 ALUM LASS LEFT 5 PUSH UL CLIOSER EADBOLT E.T.R. E.T.R. E.T.R. DOOR& E.T.R. / � _ � U � O.C. ON CENTER ALD 108C 3-0 x 7-0 1 1/2 -- ALUM/GLASS -- LEFT -- 5 PUSH/PULL/CLOSER/DEADBOLT E.T.R. E.T.R. E.T.R. DOOR&HDWE- E.T.R. LAMINATE: O.T.S. OPEN TO STRUCTURE 121 3'-O'x 7'-0' 1 3/4° SC WOOD STAIN RIGHT WOOD 4 3/4' LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N) LOCK- RE-FINISH DOOR PL-1 WILSONART 1530-60 BEIGE,AT ALL FACES PL PLASTIC LAMINIATE DATE: 5/19/2009 123 3'-0'x 7'-0" 1 3/4" SC OAK _WATCO_RIGHT TIMELY 4 7/8° PASSAGE LATCH SCHLAGE 613 AL-1 OS -- PL-2 WILSONART 4669-60 NATURAL TIGRIS COUNTER-TOP, BACKSPLASH AND SELF-EDGE. PT PAINT PERMIT SET 124 PR 21-6"x 7'-0" 1 3 4' SC OAK WATCO NA TIMELY 4 7 8" DUMMY TRIM SCHLAGE 613 (2)AL170 WITH ROLLER LATCHES _ / / O PS PLAIN SAWN 1 s 800433-3222 1 ■ TA TEC R ES. 125 3-0 x 7-0 1 3/4 SC OAK WATCO LEFT TIMELY 4 7/8" PASSAGE LATCH SCHLAGE 613 L9486 OCCUPANCY INDICATOR CONTACT H SERVICES: RC RESILIENT COV BASE CAB PULLS 613 OIL RUBBED BRONZE COVE 126 31-01x 7'-0" 1 3/4° SC OAK _WATCO RIGHT TIMELY 4 7/8' CLOSER/PASSAGE LATCH SCHLAGE 613 Al-10S -- RF RESILIENT FLAT BASE 141 3'-0'x 7'-0' 1 3/4' SC WOOD STAIN LEFT WOOD 4 3/4' LEVER/LOCK/CLOSER SCHLAGE 613 N92PD (E) DOOR-(N)LOCK-RE-FINISH DOOR DOORS, HARDWARE AND FRAMES S.A.C. SUSPENDED ACOUSTICAL CEILING 142 3'-0°x 7'-0" 1 3/4° SC OAK WATCO RIGHT TIMELY 4 7/8" PASSAGE LATCH SCHLAGE 613 AL1 OS -- DOORS PS RED OAK SV SHEET VINYL 1_ " FINISH PAC WATCO 143 x 7 4 WATCO RIGHT LATCH SCHLAGE 613 L9486 OCCUPANCY INDICATOR R 43 0 1 OAK WA G TIME 4 7 PASSAGE E LAT SC G 6 3 86 U C C O 3 0 3 C CO TIMELY S G C OCC S O 8 S THB TEMPERED HARD BOARD 1 R . MFGR PACIFIC ARCHITECTURAL WOOD PRODUCTS INC. ', R 144 3-0 x 7-0 1 3/4 SC OAK WATCO RIGHT TIMELY 4 7/8 PASSAGE LATCH SCHLAGE 613 L9486 OCCUPANCY INDICATOR ADDRESS 714 NE 55TH AVENUE, PORTLAND,OR 97213 T''P TYPICAL 146 2'-6"x 7'-0° 1 3/4° SC WOOD PAINT RIGHT WOOD 4 7/8" E.T.R. E.T.R. E.T.R. E.T.R. DOOR&HDWE- E.T.R. CONTACT DICK MARSH PHONE:(503)284-0024 FAX:(503)284-0107 WD WOOD WDW WINDOW HARDWARE 613 OIL RUBBED BRONZE FRAMES BROWN TONE J 00 09 21 00 GYPSUM BOARD b. GALVANIZED METALS: D. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR LOW AMBIENT OPERATION AND 24- ��. MV 01 00 00 GENERAL DATA HOUR USE. aa 1. NEW-WASH WITH GALVA WASH SUBSTANCE, PRIME WITH ALKYD PRIMER,AND FINISH WITH EXTERIOR ACRYLIC � v � GENERAL TO ACHIEVE UNIFORM COVERAGE. 3. PACTRUST PREFERENCE IS ZONES TYPICAL 3-5 TON BASED ON USE&EXPOSURE CRITERIA. ZONE LOADS 25 GENERAL REQUIREMENTS 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST EDITION OF THE 1. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8"THICK VERTICALLY ATTACHED TO METAL STUDS 24"O.C.WITH 1"TYPE S- 2. EXISTING-SPOT PRIMER WITH ALKYD OIL PRIMER AND FINISH WITH EXTERIOR ACRYLIC TO ACHIEVE UNIFORM GREATER THAN 5 TONS FOR PACKAGED OR SPLIT SYSTEM EQUIPMENT SHALL BE SPLIT INTO MULTIPLE ZONES. A' M 4 t DEROSIA n COVERAGE. ZONE LOADS GREATER THAN 3 TONS FOR VAV OR H2O SOURCE HEAT PUMPS SHALL BE SPLIT INTO MULTIPLE • � , W INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF OREGON AND ALL OTHER STATE OR LOCAL 12 SCREWS 12"O.C. UNLESS OTHERWISE NOTED. ZONES. CODE REQUIREMENTS THAT APPLY. 2. ALL OFFICE GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND TO FINISH COATS WITH SANDING BETWEEN FINISH C. ALUMINUM-NEW OR EXISTING, PRIME ALL RAW ALUMINUM WITH VINYL WASH PRIMER AND FINISH WITH EXTERIOR COATS. APPLY USG SHEETROCK BRAND FIRST COAT. PAINT AS INDICATED. ACRYLIC TO ACHIEVE A UNIFORM COVERAGE. 4. ALL ENCLOSED ROOMS OR OFFICES TO HAVE DUCTED SUPPLY&RETURN GRILLES. .(A PORTLAND, OREGON 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AND AT THE EXISTING BUILDING AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING THE WORK. 3. ALL OTHER GYPSUM BOARD TO RECEIVE ONE TAPE COAT AND ONE FINISH CO SANDING AFTER FINISH COAT. 4. CONCRETE WALLS: 5. VACANT SPACE SHALL HAVE DEDICATED GAS SERVICE FOR FUTURE BUILD-OUT OR FREEZE PROTECTION. . PAINT AS INDICATED. a. NEW-PRIME WITH KRILL PRIMER SEALER AND FINISH WITH HIGH SHEEN KRILL TO ACHIEVE UNIFORM COVERAGE. 6. UNITS: LENNOX,TRADE,YORK OR CARRIER-7 1/2-TON MAXIMUM UNIT SIZE. ANY UNIT IN EXCESS OF 7 1/2 TONS _f�� 3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL PERFORM DUE DILIGENCE INSPECTION OF ALL EXISTING OF o CONDITIONS PRIOR TO SUBMITTAL OF A PROPOSAL. SUBMITTAL OF A PROPOSAL SHALL BE CONSIDERED 4. AT ALL EXISTING WALLS, REMOVE ALL NAILS,SCREWS, FASTENERS,ETC. LEFT BY PREVIOUS TENANT AND PATCH b. EXISTING-SPOT PRIME WITH KRILL PRIMER SEALER AND FINISH TO HIGH SHEEN KRILL TO ACHIEVE UNIFORM SHALL HAVE SPECIAL APPROVAL BY PACTRUST. COVERAGE CONFIRMATION THAT SUCH INSPECTION HAS BEEN MADE,AND NO FURTHER COMPENSATION SHALL BE DUE HOLES READY FOR PAINT. 7. HVAC UNITS EQUAL TO OR GREATER THAN 5-TONS TO HAVE DUCTED SMOKE DETECTION AND BE CONNECTED TO THE CONTRACTOR FOR CLAIMS ARISING AS A RESULT OF FAILURE TO PERFORM SUCH INSPECTION. 10 00 00 SPECIALTIES A MONITORING STATION WITHIN THE BUILDING. PROJECT #09200 5. UPON REMOVAL OF ANY WALL BASE MATERIAL, CONTRACTOR TO PREP WALL TO PAINT READY CONDITION. 4. BY SUBMITTING A PROPOSAL,CONTRACTOR AND ALL SUBCONTRACTORS CERTIFY THAT THEY HAVE 8. UNIT PLACEMENT 24'MINIMUM TO CENTER FROM ROOF EDGE. MULTI-PLACED UNITS SHOULD BE SYMMETRICALLY EXAMINED THE SITE AND INCLUDED IN THEIR PROPOSAL ALL WORK NECESSARY TO COMPLETE THE WORK WALL CONSTRUCTION MATERIALS 10 28 13 REST ROOM ACCESSORIES IN A LINE BASED ON STRUCTURAL CALCULATIONS BY STRUCTURAL ENGINEER. 0 DESCRIBED OR REASONABLY IMPLIED IN THESE DOCUMENTS. THIS INCLUDES BUT MAY NOT BE LIMITED TO 1. PROVIDE STUDS,TRACKS,BRACING, FASTENING AND OTHER ACCESSORIES NECESSARY FOR COMPLETE !� ALL MATERIALS AND INSTALLATION,DISPOSAL OF EXCESS MATERIALS(USEABLE FINISH MATERIALS SHALL BE INSTALLATION. 1. REUSE EXISTING ACCESSORIES WHERE POSSIBLE. 9. CURBS: 14"CURBS. ASSEMBLED AND LEVELED TO ROOF,ANCHORED TO STRUCTURAL MEMBERS BELOW VJ LEFT IN THE TENANT SPACE AS DIRECTED BY PACTRUST),CLEANING AND ALL PREPARATION OF SUBSTRATE 2. PAPER TOWEL DISPENSER,SURFACE MOUNTED(ONE PER REST ROOM)BOBRICK B-262 ROOFING. r , SURFACES PRIOR TO INSTALLATION,AS WELL AS FINAL CLEAN UP. 2. FRAMING MEMBERS SHALL HAVE THE STRUCTURAL PROPERTIES INDICATED.WHERE PHYSICAL STRUCTURAL A. PROFESSIONALLY ROOF IN ALL CURBS AND PENETRATIONS BY PACTRUST SELECTED ROOFER. SEE DIVISION �J 5. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO MATCH AND MAINTAIN THE EXISTING BUILDING PROPERTIES ARE NOT INDICATED, THEY SHALL BE AS NECESSARY TO WITHSTAND ALL IMPOSED LOADS. DESIGN 3. SURFACE WALL MOUNTED SOAP DISPENSER BOBRICK B-4112(use with wall hung sink) 1 GENERAL NOTES THIS PAGE. FRAMING IN ACCORDANCE WITH AISI SG-673. STANDARDS FOR ALL EXISTING PRODUCTS AND SYSTEMS. UPON DISCOVERY OF A DISCREPANCY TO THIS 4. SURFACE MOUNTED MULTI-ROLL TOILET TISSUE DISPENSER BOBRICK B-2888 B. UNIT MUST BE LEVEL,SEALED WITH NO AIR LEAKS AND COUNTER FLASHED. < O INTENSION, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. 3. COLD-FORMED FRAMING SHALL BE GALVANIZED METAL CONFORMING TO ASTM A446/A 446 M GRADE A(33000 PSI)G60. C. CONDENSATE MUST BE TRAPPED AT UNIT. 5. SURFACE MOUNTED TOILET SEAT COVER DISPENSER BOBRICK B-4221 < O 6. FURNISH ALL NEW MATERIALS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 4. PROVIDE THE LISTED GYPSUM BOARD PRODUCTS BY U.S.GYPSUM,GEORGIA PACIFIC, NATIONAL GYPSUM OR AN 6. MIRROR STANDARD SIZES 1/4"PLATE MIRROR WITH EDGES"FLAT GROUND"BOTTOM EDGE SUPPORTED BY A CONTINUOUS 10. SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED FASHION. M 7. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES. PROVIDE CARPET'WALK-OFF MATS"TO APPROVED EQUAL. BRIGHT CHROME"J"METAL,5/16"X 3/8" (HEIGHT OF EXPOSED FACE)WITH CONCEALED LEG SCREWED TO THE WALL TO 11. ANY GAS PIPING SHALL BE STANDARD BLACK STEEL PIPE W/SUPPORTS PER CODE. PIPING SHALL BE RUN INSIDE -- 7 CARRY OF BUILDING W/LEAD FLASHINGS AT ROOF PENETRATIONS. LEAD ROOF JACKS TO BE SEALED AND CLAMPED(S.S. < • PROTECT EXISTING CARPETS. 5. STANDARD GYPSUM BOARD SHALL BE 5/8 THICK WITH TAPERED EDGES CONFORMING TO ASTM C-36. BARRY THE WEIGHT OF MIRROR. WORM GEAR). 8. ALL ROOF PENETRATIONS FROM ABANDONED EQUIPMENT TO BE REMOVED. PATCH AND REPAIR ROOF AS 6. USG FIBEROCK BRAND INTERIOR PANEL-AQUA TOUGH. 5/8"THICK,TAPERED EDGES. 7. GRAB BAR SATIN FINISH BOBRICK B-6806 SERIES �/� 1 AND NEW GAS PIPING EXPOSED TO THE EXTERIOR TO BE PROTECTED FROM RUST AND CORROSION ( ) NEEDED. 12. ALL EXISTING � 7. TRIM ACCESSORIES SHALL COMPLY WITH ASTM C-1047. 10 28 13 BREAK COUNTER WITH OIL BASED PAINT(COLOR GREY). 0 9. ALL ROOF WORK TO BE PERFORMED BY PACTRUST APPROVED ROOFING COMPANIES. APPROVED COMPANIES Q INCLUDE: WALL CONSTRUCTION EXECUTION 1. PAPER TOWEL DISPENSERS,SURFACE MOUNTED(KITCHEN/BREAK ROOM)BOBRICK B-262 13. LOW VOLTAGE WIRING SHALL BE IN SEALTITE CONDUIT FROM BELOW ROOF LINE DIRECT TO UNIT. DO NOT (�''' EXCEED BEND RADIUS MANUFACTURER'S GUIDELINE. II 0 A. ANDERSON ROOFING, (503)294-0202 1. FASTEN FRAMING MEMBERS TOGETHER BY WELDING OR BY USING SELF-DRILLING OR SELF-TAPPING SCREWS. 10 44 16 FIRE EXTINGUISHERS CC 0 B. PACIFIC ROOFING (503)640-3163 WELDING SHALL CONFORM TO AWS D13 WELDING PROCEDURE. ELECTRODES AND SCREW CONNECTIONS SHALL BE 14. ECONOMIZER TO MEET CODE AND AS FOLLOWS: ROOFING (503)643-1596 AS REQUIRED AND INDICATED IN THE DESIGN CALCULATIONS. DO NOT FIELD WELD MATERIALS LIGHTER THAN 18 GA. 1. FIRE EXTINGUISHER 2A10 BC (WALL MOUNTED OR IN SEMI RECESSED CABINET AS INDICATED ON PLAN) A. 6 TONS AND ABOVE MUST HAVE ECONOMIZER. 0 W CI i C. GRIFFITH ( ) D. GARON ROOFING AND SHEET METAL (360)254-0380 Rick N{Mcila 2. PROVIDE ACCURATELY ALIGNED RUNNERS AT TOP AND BOTTOM OF PARTITIONS. ANCHOR TRACKS AS INDICATED IN 2. FIRE EXTINGUISHER CABINET: B. BAROMETRIC RELIEF ON 5-7 1/2 TON UNITS. Cl)N 10. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS ON A DAILY BASIS INCLUDING THE DESIGN CALCULATIONS. BUTT WELD JOINTS IN TRACKS OR SPLICE WITH STUD INSERTS. FASTENERS SHALL BE AT C. 8 TONS AND ABOVE MUST HAVE POWER EXHAUST. DOCK ACCESS AREAS AND COMMON AREA. FLOORS TO BE SWEPT OR VACUUMED DAILY. �n LEAST 3 INCHES FROM THE EDGE OF CONCRETE SLABS. 72 00 00 FURNISHINGS D. 1 1/2 THRU 4-TON OSA INTAKE WITH DAMPER. 0 LO SHALL PROVIDE ADEQUATE PROTECTION TO ALL EXISTING IMPROVEMENTS INCLUDING BUT 3. CUT STUDS SQUARE AND SET WITH FIRM BEARING AGAINST WEBS OF TOP AND BOTTOM TRACKS. POSITION STUDS 1. CONTRACTOR TO REPLACE BUILDING STANDARD BLINDS AT ALL EXTERIOR GLASS AND PROVIDE BUILDING STANDARD 15. ALL UNITS TO MEET OR EXCEED CURRENT ENERGY EFFICIENCY CODE REQUIREMENTS. V J O CC C9 n I 11. THE CONTRACTOR NOT LIMITED TO BUILDING ENTRANCES, LANDSCAPING,ETC. THE CONTRACTOR WILL BE RESPONSIBLE FOR VERTICALLY IN TRACKS AND SPACE AS INDICATED IN DESIGN. DO NOT SPLICE STUDS. PROVIDE AT LEAST TWO FULL (MINI)BLINDS TO MATCH AT EXTERIOR GLASS(EXCLUDING DOORS). 16. DROP CANS TO FULL SIZE OF UNIT CURB OPENING. MINIMUM 26 GAUGE WITH SUPPLY AIR. EDGES OF SUPPLY AfR (0 0 THE REPAIR OF ANY DAMAGES TO EXISTING IMPROVEMENTS DUE TO CONSTRUCTION ACTIVITIES. HEIGHT S,AS STUDS AT DOORS AND OTHER OPENINGS 2 FEET WIDE OR LARGER. PROVIDE JACK STUDS OVER 2. CONTRACTOR TO INSTALL BUILDING STANDARD ADDRESS AND/OR SUITE NUMBER LABELS TO ALL EXTERIOR DOORS. SEALED. DROP CANS TO BE EXTENDED TO WITHIN 2'OF CEILING. O TRIPLE STUDS AT CORNERS, N N N I TO PROVIDE TEMPORARY SANITARY FACILITIES. CONSTRUCTION WORKERS SHALL NOT USE OPENINGS,AS NECESSARY,TO MAINTAIN INDICATED STUD SPACING. PROVIDE TR L , 12. CONTRACTOR POSITIONED TO RECEIVE INTERIOR AND EXTERIOR FINISHES. FASTEN STUDS AT TOP AND BOTTOM TRACKS BY 12 23 1 G CABINET SPECIFICATIONS 17. DISTRIBUTION DUCTWORK: Z (C)(C) BUILDING RESTROOM FACILITIES. WELDING OR SCREWING BOTH FLANGES TO THE TRACKS. PROVIDE DEFLECTION HEAD AT ALL WALLS WHICH EXTEND O C'7 13. STORAGE AND STAGING OF CONSTRUCTION MATERIALS SHALL BE LIMITED TO AREAS AS DESIGNATED AT PRE- TO THE UNDERSIDE OF THE ROOF STRUCTURE. 1. ALL CABINETRY TO BE INSTALLED OVER FINISH FLOOR AT ALL RESILIENT FLOORING LOCATIONS. A. SPIRAL DUCK WORK PERMITTED ONLY IF EXPOSED TO VIEW. B. 26 GAUGE OR TO SMACNA STANDARDS IF PIPE IS CONCEALED ABOVE DROP OR HARD CEILING. �'-" 0�-- 0� CONSTRUCTION MEETING. UNDER NO CIRCUMSTANCES SHALL BUILDING UTILITY AREAS OR ANY OTHER 4. INSTALL ALL INTERIOR AND EXTERIOR GYPSUM BOARD PRODUCTS AND ACCESSORIES AS REQUIRED FOR THE 2. AWI CUSTOM GRADE STANDARDS FOR CASEWORK AND COUNTER TOPS U.N.O. C. IN NON-CONDITIONED AND SEMI CONDITIONED SPACES, CC O a ..-v COMMON BUILDING AREA BE USED FOR STORAGE. PROJECT. D. WRAP CONCEALED SUPPLY DUCTWORK WITH MINIMUM R4.2 INSULATION WITH FSK BARRIER. 3. HIGH PRESSURE LAMINATE(P-LAM HPL)ALL EXTERIOR SURFACES, INCLUDING 4"TOE KICK. EDGE BANDING(MATCHING E. HANGERS 12 GAUGE WIRE OR 18-GAUGE 1"WIDE STRAP. EXPOSED DUCT MUST HAVE ALL THREAD HANGERS < LO 0 I 14. CONTRACTOR SHALL KEEP THE ROOF FREE OF DEBRIS(I.E. NAILS,SCREWS, BOTTLES, ETC.)AT ALL TIMES. 5. COMPLY WITH USG GYPSUM CONSTRUCTION HANDBOOK AND MANUFACTURER'S RECOMMENDATIONS. PVC ACCEPTABLE), FIN ENDS,DOORS,AND LIGHT VALENCE ETC. UPPER CABINET BOTTOMS OPTIONAL HPL FINISH, AND FULL 12 DIAMETER STRAP OR 18-GAUGE 18"U 0. LARGER THAN 18"MUST HAVE SADDLE AVE CLAMP. 15. ALL DIMENSIONS ARE TO FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. STANDARD MELAMINE FINISH. OPEN CABINETS OPTIONAL HPL FINISH,STANDARD MELAMINE FINISH. 6. FINISH QUALITY: F. BRANCH DUCTS SHALL BE PLUMB AND SQUARE(NO OCTOPUS). TEES SHALL BE MAXIMUM OF 45 DEGREES. -: 16. CONFIRM SIZES OF ALL OPENINGS REQUIRED FOR THE INSTALLATION OF STRUCTURAL, MECHANICAL, AREA PROCESS TRADE NOMENCLATURE 4. TOE KICK PLYWOOD 4"HIGH WITH P-LAM COVER G. EACH BRANCH DUCT TO HAVE BALANCE DAMPER IN Y BRANCH. ELECTRICAL AND PLUMBING WORK PRIOR TO FRAMING OR CUTTING FOR INSTALLATION. WAREHOUSE TAPE/FINISH COAT* TIGHT DOUBLE 5. DOORS AND DRAWER FRONTS PLASTIC LAMINATE OVER 11/16"PARTICLE BOARD WITH MATCHING P-LAM OR PVC EDGES. H. ALL DISTRIBUTION DUCT WORK TO BE INSTALLED MIN.24"ABOVE DROP CEILING. 17. LEAVE THE PROJECT CLEAN AND READY FOR OCCUPANCY. OFFICE/OTHER AREAS TAPE/2 FINISH COATS*/ SMOOTH FINISH TAPED 6. lIELAMINE(LOW PRESSURE LAMINATE/LPL)ALL INTERIOR AREAS,DRAWER PARTS,SHELVING ETC. 18. FLEX DUCT WILL BE NO LONGER THAN 6'FROM RIGID DUCT DOWN TO DIFFUSER. �1' 18. CONTRACTOR TO CLEAN ADJACENT EXTERIOR AREA, I.E.WALKS,EXTERIOR GLASS,ETC. USG"FIRST COAT" *SAND AFTER TAPE/FINISH COAT(S) 19. DIFFUSERS: F 7. FINISH EXPOSED INTERIOR GYPSUM BOARD WALLS AND CEILINGS SMOOTH STRAIGHT READY FOR TEXTURE AND/OR 7. FLUSH OVERLAY/FRAMELESS STYLE CONSTRUCTION. 19. CONTRACTOR TO FILL ALL PAPER AND SOAP DISPENSERS IN RESTROOMS AND BREAK AREAS. FINISH AS SHOWN ON PLANS. 8. HINGES-BLUM#75M3580, 110 DEG.SELF CLOSING CLIP ON(OR EQUAL). A. SUSPENDED CEILING SYSTEM(T-BAR)-PERFORATED FACE ADJUSTABLE CURVED BLADES-DESIGN TITUS PCS 0 a SUPPLY AND TITUS PAR RETURN OR APPROVED EQUAL. 20. PROVIDE"AS-BUILT'DRAWINGS OF THE WORK AT THE CONCLUSION OF CONSTRUCTION."AS-BUILT' 8. INSTALL FIBEROCK AQUA TOUGH AT TOILET ROOM WALLS BEHIND AND ADJACENT TO THE WATER CLOSET. LAY 9. DRAWER SLIDES-BLUM #230M SERIES EXTENSION(OR EQUAL)75 LBS. MIN. FOR STANDARD DRAWERS. B. GYP.BD.CEILING;SUPPLY-CURVED BLADE W/OBD DESIGN TITUS 250; RETURN-BAR TYPE-DESIGN TITUS 350; < Ul DRAWINGS MAY BE IN THE FORM OF TWO COPIES OF CONSTRUCTION DOCUMENTS MARKED-UP WITH RED HORIZONTAL,WALL TO WALL WITH NO JOINTS FROM FINISH FLOOR UP FOUR FEET. EXHAUST-METAL OR ALUMINUM-1/2"x 1/2"EGG CRATE DESIGN TITUS 50F. q. PEN.DELIVER RECORD DRAWINGS TO THE ARCHITECT. COMPLETE OPERATION AND MAINTENANCE MANUALS 10. PULL-96 MM C-TO-C WIRE PULLS. FINISH TO MATCH DOOR HARDWARE. C. ALL SUPPLY REGISTERS TO HAVE MANUAL VOLUME DAMPERS LOCATED IN DUCT AT/OR NEAR CLOSEST WYE CV PI SHALL BE PROVIDED FOR ALL MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT. PACTRUST MAY HOLD 09 53 00 SUSPENDEID ACOUSTICAL CEILING 11. GENERAL CONTRACTOR TO PROVIDE CABINET MAKER WITH SINK TEMPLATE(SPEC SHEETS)FOR EACH SINK. SINK BRANCH. CC CONTRACTOR'S FINAL PAYMENT UNTIL"AS-BUILT'DRAWINGS AND 0&M MANUALS HAVE BEEN RECEIVED AND - r Lill ON 1. COMPLY WITH CURRENT SEISMIC REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE. CUTOUT WILL BE DONE IN SHOP WHEN FEASIBLE AND BEFORE BACK SPLASH IS INSTALLED IN ALL CASES TO ALLOW CUT D. CLEAN OR REPLACE ALL SUPPLY AND RETURN AIR GRILLS AND THEIR HOUSINGS AT PROJECT COMPLETION. APPROVED. OUT TO BE POSITIONED PROPERLY. ALL RAW EDGES OF CUT OUT AND BACK SPLASH TO BE SEALED. MINIMIZE tr a 21. IT IS THE INTENT OF THE CONTRACT DOCUMENTS THAT THE CONTRACTOR PROVIDES A COMPLETE, 2. FOLLOW MANUFACTURERS PRINTED INSTRUCTIONS FOR THE DELIVERY AND INSTALLATION OF CEILING SYSTEM, COUNTERTOP BUILD UPS AT FRONT AND BACK OF SINK CUT OUT TO ACCOMMODATE PLUMBERS SINK CLAMPS 20. THERMOSTAT: ALL EXISTING MERCURY TYPE THERMOSTATS TO BE REPLACED. NEW THERMOSTATS TO BE F- FUNCTIONING PROJECT INCLUDING ALL GENERAL, MECHANICAL AND ELECTRICAL CONSTRUCTI O N REQUIRED INCLUDING GRID, PANELS,AND HANGARS AND ACCESSORIES. CLEARANCE. HONEYWELL COMMERCIAL GRADE VISIONPRO 8000 TOUCH SCREEN MODEL TB8220U1003 WHERE POSSIBLE. 0 ........ aii. Q TO FULFILL THAT INTENT. ALL ITEMS REQUIRED SHALL BE FURNISHED AND INSTALLED, REGARDLESS OF 3. USE ALL PRODUCTS FROM ARMSTRONG WORLD INDUSTRIES, INC. 12. KITCHEN/BREAK ROOM CABINETS-BASE CABINET WITH P-LAM TOP ON PLYWOOD DECKING AND 4"BACK SPLASH. ALL APPROVED SUBSTITUTE: TOTAL-LINE SIGNATURE COMMERCIAL THERMOSTAT MODEL NO.P374-2800 -7 DAY WHETHER OR NOT SHOWN ON THE DRAWINGS. CABINETS TO HAVE DOORS AND DRAWERS, U.N.O. UPPERS 12"D X 36"H,COUNTER AND COUNTERTOPS 26"D. PROGRAMMABLE WITH LOCKOUT FUNCTION-AUTO CHANGEOVER ONLY. MOUNT AT ADA HEIGHT(MAY REQUIRE r 4. CO-ORDINATE CEILING WORKWITH INSTALLERS OF RELATED WORK INCLUDING BUT NOT LIMITED TO INSULATION, CHANGING HEIGHT AT"REPLACEMENT'LOCATIONS). CONTRACTOR SHALL PROGRAM THERMOSTATS AND Cio. FIM 22. ITEMS OR WORK NOT TO BE FURNISHED OR ACCOMPLISHED BY CONTRACTOR ARE NOTED"N.I.C.". GYPSUM BOARD,LIGHT FIXTURES,MECHANICAL SYSTEMS, ELECTRICAL SYSTEMS AND FIRE SPRINKLERS MICROWAVE SHELF 18"D WITH 3"RADIUS OUTSIDE CORNERS. P-LAM AT TOE/BASE. ALL SHELVES ADJ.HOLES AND POSTS BALANCE SYSTEM. D (9 7.1 ' 23. "ALIGN"AS USED IN THESE DOCUMENTS, MEANS TO ALIGN THE FINISHED FACES OF ELEMENTS IN THE SAME (1 AT BASE,2 AT UPPERS}. ACROSS AN OPENING. 5. PRODUCTS: 21 00 00 FIRE SUPPRESSION 21. THERMOSTAT LOCATIONS TO BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. PLANE, EITHER IMMEDIATELY ADJACENT TO ONE ANOTHER OR AC z a. GRID-PRELUDE 24 XL 15/16"EXPOSED TEE(HEAVY DUTY) 22. WAREHOUSE HEAT: 24. DO NOT DISASSEMBLE SETS OF CONSTRUCTION DRAWINGS.DRAWINGS ARE INTERRELATED. b. TILES-ARMSTRONG FISSURED ITEM#705,24 x 24 x 5/8"W/ANGLED TEGULAR EDGE 1. PROVIDE SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER HEADS SHALL BE CENTERED IN 2 X 2 CEILING A. GAS FIRED UNIT HEATERS USED IN NON-CONDITIONED AREAS SHALL COMPLY WITH CURRENT STATE ENERGY �_Ism 25. SUBMIT SAMPLES OR DRAW DOWNS FOR ALL FINISHES TO THE ARCHITECT OF RECORD WITHIN TWO WEEKS C. ACCESSORIES-MANUFACTURERS'STANDARD TILE.LAYOUT OF SPRINKLERS BY CONTRACTOR. SPRINKLER LAYOUT IN ALL HARD CEILING AREAS(GYPSUM CODE REQUIREMENTS. PROVIDE ADJUSTABLE T-STAT FOR EACH UNIT. OF PROJECT AWARD. PRODUCTS INSTALLED WITHOUT APPROVED SAMPLES ARE SUBJECT TO REPLACEMENT 6. ALL TILE CUTS SHALL BE DONE WITH RAZOR SHARP KNIVES. CUT/TRIM TILE EDGE TO CREATE TEGULAR EDGE BOARD/PLASTER)TO BE REVIEWED AND APPROVED BY ARCHITECT PRIOR TO INSTALLATION. AT CONTRACTOR COST. CONDITION SO THAT CEILING TILE LAYS FLAT. 2. IN NEW CEILING GRID SYSTEMS OVER 144 SF PROVIDE FLEXIBLE HEADS FOR MINIMUM SEISMIC MOVEMENT. NO"OOPS B. RETURN INACTIVATED UNIT HEATERS TO ACTIVE USE.SERVICE UNITS AS REQUIRED. m 14 26. CONTRACTOR SHALL SUBMIT COMPLETE SHOP DRAWINGS FOR MILLWORK,SPECIAL SYSTEMS, MECHANICAL, 7. AT CEILINGS OVER 144 SF PROVIDE HORIZONTAL RESTRAINT WIRE OR RIGID BRACING. RINGS ALLOWED". 23. EXHAUST FANS: ELECTRICAL AND PLUMBING SYSTEMS(INCLUDING FIRE PROTECTION SYSTEMS). SUBMIT A MINIMUM OF iW0 3. !'RQVIDE AUTOMATIC FIRE SPRINKLER FLOW INDICATOR SIEMENS CU-MHU-MCS-W OR EQUAL.LOCATION TO BE APPROVED A. CEILING MOUNTED EXHAUST FANS SHALL HAVE A MINIMUM PERFORMANCE TO MEET THE CURRENT CODE Ono COPIES OF ALL SHOP DRAWINGS FOR REVIEW AND APPROVAL TO THE ARCHITECT OF RECORD.ARCHITECT 8. AT CEILINGS OVER 144 S.F.: BY ARCHITECT. REQUIREMENTS INCLUDING INTEGRAL BACKDRAFT DAMPER AND VENTING TO THE EXTERIOR.COOK GEMINI WILL RETAIN ONE COPY AND ONE COPY WILL BE RETURNED TO THE CONTRACTOR. a. INSTALL GRID USING BERC2 CLIPS TO ATTACH GRID TO WALL MOLD AS AN ALTERNATE MEANS OF CONSTRUCTION SERIES 100 OR EQUAL;80 CFM WITH A SONE RATING OF 1.6 OR LESS, 100 CFM WITH A SONE RATING OF.9 OR 27. THE DESIGN OF FIRE PROTECTION SYSTEMS IS THE RESPONSIBILITY OF THE FIRE PROTECTION SYSTEMS FOR THIS PROJECT WITH TWO ADJACENT SIDES RIGIDLY ATTACHED AND THE OTHER TWO SIDES ALLOWED TO 22 00 00 PLUMBING LESS,200 CFM WITH A SONE RATING OF 1.6 OR LESS. CONTRACTOR.ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER FLOAT. B. SINGLE FIXTURE RESTROOMS,JANITOR'S CLOSETS OR SINGLE SHOWER ROOMS TO HAVE CEILING MOUNTED LICENSED BY THE APPROPRIATE JURISDICTION FOR THE DESIGN OF THIS TYPE OF SYSTEM. COORDINATE GENERAL REQUIREMENTS EXHAUST FANS,WIRED BY DIVISION 16 AND SWITCHED WITH THE LIGHTS. INTERFACE WITH EXISTING BUILDING SYSTEMS AND WITH ARCHITECT. ALL SPRINKLER HEADS SHALL BE 9. PROVIDE RIGID STRUTS TWELVE FEET ON CENTER EACH WAY BEGINNING WITHIN SIX FEET OF PERIMETER EDGE. 24. HVAC TESTING. CENTERED IN CEILING TILE(OR 2 x 2 MODULE OF A SECOND LOOK II TYPE OF CEILING TILE WHERE INSTALL SWAY BRACING EACH STRUT ALONG FIXED EDGE IN ALL FOUR DIRECTIONS 1 PLUMBING BEHIND CONTRACTOR CLOSET O N MEN'S RESTROOM.INSTALL 1)MASTER SHUT OFF VALVE FOR EACH SET OF RESTROOMS. LOCATE SHALL BE PRE-APPROVED IN WRITING BY TUNE UP GRID SYSTEM AS NEEDED. A. CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES,COMPONENTS,EQUIPMENT AND 0 APPLICABLE). LOCATION OF THOSE IN GYPSUM BOARD CEILINGS A 10. IN EXISTING SPACES REPLACE WATER STAINED OR DAMAGED TILES AS NEEDED. SYSTEMS ARE CALIBRATED,ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND THE ARCHITECT PRIOR TO INSTALLATION. 2. WATER HEATER(ELECTRIC)5 GAL, 120V. PROVIDE OVERFLOW DRAIN TO FLOOR DRAIN BELOW. SPECIFICATIONS. 11. REPAIR HOLES IN GRID FROM REMOVED WALLS. USE OF ARMSTRONG"BP ES-4"EXPANSION SLEEVE ACCEPTABLE. B. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE 28. THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION SEQUENCING WITH PACTRUST AND SCHEDULE 3. FLOOR DRAINS SHALL BE INSTALLED IN TOILET ROOMS WITH APPROVED PLANS AND SPECIFICATIONS. ALL SERVICE INTERRUPTIONS OUTSIDE NORMAL BUSINESS HOURS TO MINIMIZE INCONVENIENCE TO CURRENT 09 65 19 RESILIENT FLOORING -RESILIENT FLOORING C. A COMPLETE APPROVED PLANS COMMISSIONING REPORT SPECIFICATIONS. TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED 18"ACCESS DOOR. 4. FLOOR DRAINS TO BE INSTALLED WITH PRIMER VALVE WITH ISOLATION VALVE. PROVIDE A MIN. OF 18 C TENANTS. 1. PLACE A CONTINUOUS BEAD OF SEALANT TO SEAL THE EDGE OF THE VINYL FLOORING TO THE WALL. AS THE 6" WITH PACTRUST. GENERAL RUBBER BASE IS INSTALLED,APPLY A BEAD OF SEALANT TO SEAL THE RUBBER BASE TO THE FLOOR AND THE TOP OF PLUMBING - REST ROOM FIXTURES (SINGLE OCCUPANCY) THE RUBBER BASE TO THE WALL. 25. PROJECT CLOSE OUT DOCUMENTS REQUIRED: X 1. REMOVE ALL EXISTING VCT SHEET VINYL, ETC. IN AREAS WHERE NEW FLOOR COVERING IS SPECIFIED PRIOR 1. REUSE EXISTING FIXTURES WHERE POSSIBLE A. AUTOCAD FILE SHOWING AS-BUILT INFORMATION. TO INSTALLATION OF NEW FLOORING. 09 91 23 PAINTING HARD COPY OF AUTOCAD FILE ABOVE. 2. FLOOR MOUNT TANK TYPE WATER CLOSET- TOTO CST744SL OR KOHLER CIMARRON K3496 C. OPERATIONS MANUALS FOR ALL EQUIPMENT, INCLUDING T STATS. 2. ALL ROOF PENETRATIONS FOR ELECTRICAL,LOW VOLTAGE,GASP I ETC.SHALL BE SLEEVED THROUGH A INTERIOR: 3. LAVATORY FAUCET DELTA 501 WF D. COLORED ZONE MAP WITH THERMOSTAT LOCATIONS INDICATED. 0 LEAD ROOF JACK,CLAMPED WITH A STAINLESS STEEL CLAMP AND SEALED WITH VOLKUM CAULKING. ill SILICONE SEALANT NOT PERMITTED. 1. WALLS: 4. PROVIDE FLOOR DRAINS WHERE INDICATED. 26 00 00 ELECTRICAL Q 01 23 00 ADD ALTERNATE PRICING REQUIRED a. PRIME NEW DRYWALL WITH MILLER'S HIGH-BUILD"SUPER SEAL"PRIMER. 5. CAULKING OF PLUMBING FIXTURES: b. NEW AND EXISTING DRYWALL TO BE FINISHED TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 4480 WITH GENERAL Z A TIGHT ROLLER STIPPLE FINISH. RESTROOM FINISHES TO BE MILLER'S SIG LATEX ENAMEL. A. ALL CAULKING SHALL MATCH GROUT COLOR AT TILE SURFACES. a.1. B. SUBMIT CAULKING COLOR PRIOR TO INSTALLATION FOR ARCHITECT APPROVAL FOR ALL OTHER APPLICATIONS. 1. ALL ELECTRICAL FEEDS TO OUTLET,SWITCHES,ETC. MUST BE VERTICAL DROPS FROM CEILINGS U.N.O. EXCEPT 2. DOORS AND FRAMES: HORIZONTAL RUNS UNDER WINDOWS AND FIXTURES ON THE SAME STUD WILL BE PERMITTED. 03 00 00 CONCRETE a. NEW HOLLOW METAL-PRIME,SAND,AND FINISH WITH TWO COATS OF SEMI-GLOSS OIL. PLUMBING - REST ROOM FIXTURES (MULTI OCCUPANCY) 2. UPDATE ALL PANEL SCHEDULES TO CURRENT CONFIGURATIONS. Q 1. EXTERIOR FLAT WORK: b. EXISTING HOLLOW METAL-SAND, FILL IMPERFECTIONS WITH BONDO,SAND AND PRIME PATCHES WITH ALKYD 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. 3. ELECTRICAL CONTRACTOR TO PROVIDE LABELS AT EACH ELECTRICAL RECEPTACLE IDENTIFYING <a. U) PRIMER,AND FINISH WITH SEMI-GLOSS OIL ENAMEL. (11 O N a. 4"THICK UN-REINFORCED CONCRETE SLAB WITH AIR-INTRAINMENT OVER 4"COMPACTED CRUSHED ROCK C. NEW WOOD-PRIME WITH ALKYD OIL UNDER-COATER,SAND, FILL ALL FASTENING HOLES WITH PAINTER'S PUTTY, 2. COUNTERTOP LAVATORY KOHLER K-2196-4 (3/4 MINUS). CORRESPONDING ELECTRICAL PANEL AND CIRCUIT BREAKER. , 0 b. CONTROL JOINTS 5'O.C. MAX, EXPANSION JOINTS 20'O.C.OR AS SHOWN ON PLANS. CAULK ALL CRACKS IN CASINGS AND BETWEEN JAMBS AND WALLS USING DAP LATEX CAULK,AND FINISH WITH S/G 3. LAVATORY FAUCET DELTA 501 WF 4. CONTRACTOR TO VERIFY ELECTRICAL METER AND TAG METER WITH THE TENANTS ADDRESS OR SUITE NUMBER. W OIL ENAMEL. Cfl C. BROOM FINISH WITH TOOL EDGE EACH SIDE. 4. TOILET W/FLUSHOMETER-AMERICAN STANDARD AS 2234.015 AT NON ACCESSIBLE STALLS AND 2305.100 AT ACCESSIBLE METER IDENTIFICATION NUMBER,LOCATION AND TENANT ADDRESS INFORMATION SHALL BE GIVEN TO ARCHITECT Z cc d. EXISTING WOOD-PREP REPAIR IMPERFECTIONS, PRIME AS REQUIRED,AND REPAINT WITH SEMI-GLOSS OIL PRIOR TO TENANTS MOVE-IN. VALVE 111 OR TANK TYPE TOTO CST744SL A S INDICATED ON PLAN LOCATIONS. FLUSHOMETER SLOAN FLUSH V AS REQUIRED,AND RE-VARNISH WITH SATIN VARNISH. (n O 07 00 00 THERMAL & MOISTURE PROTECTION ENAMEL. IF FINISH IS NOT PAINTED,TOUCH UP STAIN,SEAL A , 3. CEILINGS: 5. URINAL-TOTO UT104,OR KOHLER K-5016-ET W/FLUSH VALVE SLOAN 186-1 5. ELECTRICAL CONTRACTOR TO PROVIDE EMERGENCY LIGHTING IN EXIT PATH EQUAL TO 1-FOOT CANDLE. al V THE CEILING GRID _ 6. FOR F�CIT LIGHTS USE RUUD LIGHTING"PLASTIC LED EXIT SIGN"MODEL EXPBURWH RED LETTERS,WHITE m �j WALL INSULATION ABOVE T 4 D P TO REPLACE ALL MISSING OR DAMAGED ROOF AND _ H1 LP WITH ROUGH OPENING OF 38 WIDE BY 2 EE 1. CONTRACTOR G MODEL#38 - SS TED LIVIN SHOWER STALL FIBERFAB A IS 6. S OW AS NEEDED. a. EXISTING PLASTER-SAND,SPACKLE ALL IMPERFECTIONS,SPOT PRIME AND FINISH TO ACHIEVE UNIFORM HOUSING,WITH BATTERY BACKUP. Q z T__ (U Z COVERAGE WITH MILLERS 6200 OR 4480. 7. PROVIDE ONE FLOOR DRAIN IN EACH RESTROOM LOCATED UNDER TOILET PARTITION. 0 2. CONTRACTOR TO INSTALL NEW ROOF INSULATION TO MATCH EXISTING IN ALL ABANDONED HVAC UNIT b. NEW PLASTER-PRIME WITH SUPER SEAL AND FINISH TO ACHIEVE UNIFORM COVERAGE WITH MILLER'S 6200 OR 7. WHERE NEEDED,CONTRACTOR TO FURNISH AND INSTALL NEW DRY TYPE TRANSFORMERS TO PROVIDE 208V/120V 0 LOCATIONS. 4480 8. SEAL PLUMBING FIXTURES TO FLOOR OR WALL: POWER FROM THE 480V/277V SYSTEM. SIZE TO BE BIDDER DESIGN. C'3 !- R AND WINDOWS 4. GENERAL NOTES: A. SUBMIT SEALANT COLOR TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION a. TRANSFORMERS TO BE ENERGY STAR LABELED. R 0 ©s �000DOO S b. CASE TO BE TOTALLY ENCLOSED WITH LOUVERS TO PREVENT FOREIGN OBJECTS INTO THE fNTER{O O r a 1. RE-USE EXISTING DOORS AND FRAMES WHERE POSSIBLE a. KEEP ALL HARDWARE, HINGES,AND DOOR KNOBS CLEAN OF ALL PAINT SPLATTERS,DRIPS,OR ROLLER SPRAY. PLUMBING - BREAK ROOM FIXTURES C. ENCLOSED AND VENTILATED,AIR COOLED TYPE,CLASS H INSULATION, DESIGNED FOR 115 DEGREES C b. ALL SURFACES TO BE SANDED BETWEEN COATS, PRIOR TO INSTALLATION OF NEXT COAT. 1. REUSE EXISTING FIXTURES WHERE POSSIBLE. TEMPERATURE RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD CONTINUOUS OPERATION. 2. DOOR FRAMES SHALL BE WESTERN INTEGRATED MATERIALS(WIM),ALPHA ALUMINUM PRODUCTS, INC.(AAP), c. DURING PROGRESS OF WORK, KEEP JOB SITE CLEAN OF ALL PAINT MATERIALS,RUBBISH,CANS,AND RAGS AT THE EQUIP WITH 2-1/2 PERCENT ANFC TAPS AND FOUR 2-1/2 PERCENT BNFC TAPS. MAXIMUM SOUND LEVEL SHALL REVISIONS TIMELY II,OR APPROVED. SUBMITTAL REQUIRED PRIOR TO ORDERING MATERIAL. NEW FRAMES TO BE END OF EACH DAY. 2. BREAK ROOM SINK ELKAY CR-2522 BE NEMA STANDARD WITH ISOLATION DAMPERS BETWEEN THE CORE AND COIL ASSEMBLYAND CASE. FACTORY FINISH CUSTOM COLOR. d. UPON COMPLETION OF WORK,CLEAN ANY PAINT SPLATTER BY USING PROPER METHODS OF WASHING AND 3. FIELD VERIFY EXISTING FRAME FINISH PRIOR TO ORDERING NEW FRAMES. ALL NEW FRAMES TO MATCH SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. 3. KITCHEN FAUCET DELTA 100-WF 8. TELECOMMUNICATION SYSTEM BY FUTURE TENANT. EXISTING BUILDING STANDARD FRAMES. e. PROTECT WORK OF OTHER TRADES. 23 00 00 HVAC 9. WHEN REQUIRED IN DIVISION 15, PROVIDE MONITORING OF HVAC EQUIPMENT PER CODE. 1 . f. PROVIDE WET PAINT"SIGNS AS REQUIRED TO PROTECT NEWLY PAINTED FINISHES. 4. ALL DOORS SHALL BE SOLID CORE WOOD UNLESS NOTED OTHERWISE. GAS METER 10. CONTRACTOR TO REMOVE ALL UNUSED DATA AND POWER BOXES AND INFILL WITH GYP BOARD. EXCEPTION- ` 2. 5. DOOR HARDWARE SHALL BE SCHLAGE AL SATURN OR D RHODES SERIES U.N.O. EXTERIOR: UNUSED DATA BOXES UNDER WINDOW SILLS TO REMAIN. ALL BLANK COVER PLATES TO BE BUILDING STANDARD 1. WASHING: 1. CONTRACTOR TO VERIFY GAS METER AND TAG METER WITH THE TENANT SPACE ADDRESS OR SUITE NUMBER. METER FINISH. 3. 6. ALL HARDWARE SHALL BE INSTALLED WITH A 5"BACKSET. IDENTIFICATION NUMBER AND ADDRESS INFORMATION SHALL BE GIVEN TO ARCHITECT PRIOR TO COMPLETION., OFFICE LIGHTING 7. DOOR FINISH SUBMITTAL:CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR DOOR FRAMES, DOOR HARDWARE a. ALL SURFACES TO BE PAINTED ARE TO BE PRESSURE WASHED USING A PRESSURE WASHER WITH A MINIMUM 4. AND DOORS AS WELL AS A CONTROL SAMPLE OF THE FINISHED DOOR SKIN W/STAIN AND FINISH APPLIED(IF PRESSURE OF 2500 PSI. HVAC - BID PROCEDURE 1. OFFICE LIGHT FIXTURES-LITHONIA 2PM3N G B 3 32 18LD MVOLT ADVANCE OR EQUAL.(NO SYLVANIA BALLASTS) EQUIPMENT IS IN PROPER 5. WILL ASSUME THAT EXISTING HVAC Q -THE HVAC CONTRACTOR W i LT GEB 101S OR EQUAL NEW DOORS ARE BEING PROVIDED). BEFORE FINISHING OF DOORS IS COMMENCED ARCHITECT SHALL b. AFTER WASHING: 1. FOR BIDDING PURPOSES, H 2. REST ROOM-WALL MOUNTED LIGHT FIXTURE LITHONIA WC 2 32 MVO O SAMPLE. FINISHED PRODUCT IS SUBJECT TO REJECTION BY ARCHITECT IF THIS PROCESS WORKING ORDER. 6"APPROVE CONTROL S 1. DO NOT PAINT OVER DIRT, RUST, SCALE, GREASE,AND MOISTURE. SCRAPE ALL SURFACES TO REMOVE ANY MATCH THE APPROVED CONTROL SAMPLE. 3. RECESSED DOWN LIGHT: RUUD LIGHTING R7FT,6' FLUORESCENT QUAD TUBE(2-13W) G. IS NOT FULLY ADHERED TO AND FIELD PRODUCT DOES NOT MATC T SCALE. 2. INVENTORY EXISTING H.V.A.C. ROOFTOP UNITS AND SUBMIT TO ARCHITECT A CONDITIONS REPORT OF EACH UNIT 8. ALL INTERIOR GLAZING SHALL BE TEMPERED. 2. ALL IRREGULAR SURFACES TO BE FEATHERED OUT AT EDGES BY SANDING. 3. LIST TONNAGE OF EACH UNIT. 4. EXTERIOR SOFFIT DOWN LIGHT: RUUD LIGHTING R7FEM 6"QUAD TUBE(1-13W)W/EMERGENCY BALLAST.WITH TE THINNER TO CLEAN. ADAPTER FOR SLOPED CEILING. P 9. DEAD BOLT LOCKS AT NEW EXTERIOR DOORS TO BE INSTALLED WITH A SCHLAGE MORTISE DOUBLE CYLINDER 3. ALL METAL SURFACES WITH VISIBLE SOILING TO BE WIPED WITH A PR OPRIA T 20-013C "C'KEYWAY;SOLID BRASS;WITH ADAMS-RITE CAM AND COMPRESSION RING 1 1/8"LENGTH WITH 4. SPACKLE ANY IMPERFECTIONS IN SURFACE WITH EXTERIOR SPACKLE,SPOT PRIME PRIOR TO INSTALLATION HVAC - DESIGN PROCEDURE STANDARD. OF FINISH COATS. DESIGN STANDARDS LISTED BELOW. WAREHOUSE LIGHTING HARDENED CYLINDER GUARD RING KEEDEX K-24. FINISH TO MATCH BUILDING 5. CAULK SEAMS AT JUNCTION OF ADJOINING SURFACES WHERE OPENINGS ARE VISIBLE TO THE EYE. USE EXISTING AND/OR NEW EQUIPMENT TO DESIGN MECHANICAL H.V.A.C.SYSTEM PER DE W 1. RUDD LIGHTING,TO LAMP,54W,T5H0 FLUORESCENT 277V.(H1A2X54-U4 2LMP 54W). MOUNTING HEIGHT AT 13'4" 10. PATCH AND REPAIR ALL HOLES OR DAMAGE TO EXISTING STORE FRONT WINDOWS AND DOORS.TOUCH UP 2. WOOD SURFACES I.E.SIDING,FASCIA BOARDS,SOFFITS, ETC: PRIOR TO AWARD OF CONSTRUCTION CONTRACT,H.V.A.C. CONTRACTOR SHALL SUBMIT TO ARCHITECT FOR REVIEW AND A.F.F. FINISH FOR AS NEW LOOK. DRAWN BY: APPROVAL FULL DESIGN SCHEMATIC FOR ALL UNITS IN THE TENANT SPACES INVOLVED.INCLUDE THE FOLLOWING: 11. TOUCH UP ALL EXISTING INTERIOR DOORS AND FRAMES FOR AS NEW LOOK. a. RAW WOOD: 28 30 00 ELECTRONIC DETECTION AND ALARM ALD 1. PRIME WITH EXTERIOR CONTROL PRIMER IF TO BE PAINTED. A. DUCTING AND SIZES 12. RETURN THE OVERHEAD DOORS ABOVE THE CEILING TO USE AFTER THE STOREFRONT IS REMOVED.TUNE UP B. SUPPLY AND RETURN LOCATIONS AND CFM GENERAL ALL OVERHEAD DOORS AS NEEDED. 2. PRIME WITH THINNED SOLID COLOR STAIN IF STAIN IS TO BE USED. C. ROOF EQUIPMENT,SIZES AND LOCATIONS DATE: 5/19/2009 3. PRIME WITH THINNED EXTERIOR ACRYLIC IF EXTERIOR ACRYLIC IS TO BE USED. D. UNITS REQUIRING DUCTED SMOKE DETECTION FOR HORN/STROBE DEVISES USE"SYSTEM SENSOR"SPECTRALERT ADVANCE DEVISES,OR APPROVED EQUAL. PERMIT 09 00 00 FINISHES b. PRIMED WOOD AND EXISTING FADED WOOD AREAS: E. THERMOSTAT LOCATIONS AND ZONE/UNITASSOCIATED THEREWITH PERMIT SET 1. APPLY FINISH OF MILLER'S ACRILITE TO TOTAL SURFACE TO ACHIEVE UNIFORM COVERAGE. F. ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS 32 00 00 EXTERIOR IMPROVEMENTS, GENERAL G. ZONE DIAGRAM 2. ANY NEW SIDING TO BE PRIMED PRIOR TO INSTALLATION. PRIOR TO ANY EXTERIOR EXCAVATION OR BORING,GENERAL CONTRACTOR SHALL OBTAIN AN UNDERGROUND UTILITY 1. CLEAN, SEAL AND WAX ALL RESILIENT FLOORS PER MANUFACTURERS SPECIFICATIONS. HVAC DESIGN STANDARDS LOCATE. C. WOOD TRIM: 2. SUBMIT SAMPLES OR DRAW DOWNS FOR THE FOLLOWING: THE FOLLOWING ARE MINIMUM DESIGN STANDARDS: T �_. FINISHED WITH MILLER'S ACRILITE.BE PRIMED AND F( H 1. ROUGH WOOD TRIM TO E a. FLOOR COVERINGS AND BASE 2. SMOOTH WOOD TRIM TO BE PRIMED WITH ALKYD OIL PRIMER AND FINISHED WITH SEMI-GLOSS ACRYLIC. 1. 350 SQUARE FOOT PER TON. b. PLASTIC LAMINATES 3. METAL SURFACES I.E.SIDING, ROOFING, DOORS, FRAMES,GUTTERS, ELECTRICAL PANEL COVERS,ETC: 40,, C. ALL NATURAL WOOD(INCLUDING DOORS AND CASEWORK) 2. ADDRESS LOADS BY SPECIFIC LOCATION AND USE. sumo d. PAINT COLORS a. FERROUS METALS: A. EXTERIOR EXPOSURE AREAS i e. HARDWARE 1. NEW-PRIME WITH ALKYD OIL PRIMER, FINISH WITH EXTERIOR ACRYLIC TO ACHIEVE UNIFORM COVERAGE. B. INTERIOR AREAS,SIZE AND USE 3. RESILIENT FLOORING SHALL EXTEND UNDER ALL NEW CASEWORK. 2. EXISTING-SPOT PRIME RAW AREAS WITH ALKYD OIL PRIMER AND FINISH WITH SEMI-GLOSS ACRYLIC TO C. CONFERENCE/TRAINING ROOMS ACHIEVE UNIFORM COVERAGE.