Loading...
Plans -sJ 1 ... ,_ . 1 _ 1, _.,_ 00 9 40 Akcif. FLOOR PLAN GENERAL I � x:. �E E LECTE ® AEI LI NG NOTES � „� Nq. 1881 o►wa VOn. ►--.3 1. ALL WORK AND MATERIALS TO CONFORM TO BUILDING STANDARDS UNLESS 1. ALL PARTITIONS TO BE INSULATED UNLESS NOTED OTHERWISE-REFER TO SHEET T-1 '*.... NOTED OTHERWISE. L�• •- D, OREGON FOR WALL DETAILS. � 4�� =' AREA OF WORD 2. REPLACE CHIPPED, POORLY CUT AREA OF ���' `i r 00 CU OR DAMAGED CEILING TILES. 2. ALL WORK AND MATERIALS TO CONFORM TO BUILDING STANDARDS UNLESS '.�,� �� s_. a ..:.��.�z, ► O 3. DOWN LIGHTS TO BE CENTERED IN ACOUSTICAL TILE, UNLESS NOTED OTHERWISE. NOTED OTHERWISE. n , �- 3. PROVIDE BUILDING MANAGEMENT WITH AS BUILT DOCUMENTATION/DRAWINGS i - }I�{ 4. SWITCH LIGHT FIXTURES AS REQUIRED AND AS SHOWN ON REFLECTED CEILING - - H dff- AT COMPLETION OF CONSTRUCTION. PLAN. N Z i :, �� t° 5. PROVIDE BUILDING MANAGEMENT WITH AS BUILT DOCUMENTATION/DRAINING :.11::Nt ® 4. ALL NEW WALLS TO HAVE SMOOTH WALL FINISH-NO TEXTURE-PAINT TO MATCH Z N 8• 1 + AT COMPLETION OF CONSTRUCTION. ,; ' EXISTING. z � � z I ' . ,. iii I _ • ZO 2 I -e N I W -� O — FLOOR PLAN KEYNOTES_ _ 0 . REFLECTED EILlN ICEYNO►TE` I 1 3 NEW 3'-0"WIDE DOOR, FRAME,AND RELITE TO MATCH BUILDING STANDARD-PROVIDE £ A 10-21/2" 1 ZO ALIGN � O TENANT STANDARD ADA COMPLIANT HARDWARE. �.- I RI J 17 LL,,.s�,� � RELOCATE LIGHT FIXTURE � N I° p LA K1I: PROVIDE NEW LIGHT SWITCH Z a. d- O M O w ° III I � Lu ° Ce D V cn - - — Imo- . O Q r . REFLE TED CEILING SYMBOLS 1 ° N $ SWITCH < N F EXISTING 2 x 4 LAY-IN FIXTURE FLOORPLANSYMBOLS o 0 F LETE CE I LI NG PLA N L OR PLAN : , W "e NEW/RELOCATED 2 x 4 LAY-IN FIXTURE _ r cy 1/$ 1 0 1/8"=1 -0 _ EXISTING WALL TO REMAIN . _ O ,o a REMOVED FIXTURE MN INSULATED PARTITION WALL AI INF ` EXISTING HVAC(SHOWN FOR REFERENCE ONLY) 0 TO CEILING GRID I I EXISTING HVAC(SHOWN FOR REFERENCE ONLY) OFFICE ROOM NAME + EXISTING SPRINKLER HEAD (SHOWN FOR REFERENCE ONLY) 100 ROOM NUMBER ABBREVIATIONS E -EXISTING N -NEW I RELOCATED 2 KEYNOTE 0 -DEDICATED DUPLEX RECEPTACLE AR WARE NOTES ::: WALL 4-PLEX ® WALL VOICE/DATA OUTLET 1. MAIN EXIT DOOR TO HAVE SIGNAGE ABOVE THE DOOR STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" ABBREVIATIONS 0 E -EXISTING 0 2. EXIT DOORS ARE OPERABLE FROM THE INSIDE WITHOUT THE USE N -NEW OF A KEY, SPECIAL KNOWLEDGE OR FORCE. R -REMOVED LL. RL -RELOCATED • 3. ALL HARDWARE IS ADA COMPLIANT. --44" -MOUNTING HEIGHT 0 AFF.TO 4. z 4. PROVIDE 18 GA. BACKING AT ALL WALL STOP LOCATIONS, IF D -DEDICATED N APPLICABLE. . v CSI U Q Z Z = 0 z 1--- � LT. Z °3 o z co ,,, 0- 0 O (j cv , D 4" 7YP. DOOR OFFSET AT 1, a METAL STUD TABLE MAX WALL HEIGHT U240 �- E°°' CA L1.1 _.,,_ ,__ . .,_...........__. ....,_.._.. .._._.._..._...... ._.__,_.. _. ,...,. STUD SIZE GAGE STUD DESIGNATION SPACING MAX WALL HEIGHT TWO FIXTURE HANGING WIRE AT / " PERPENDICULAR WALL if SECURE TO HANDLE APPLIED LOADS TE COMPOST SECTION NON-COMPOSITE SECTION OPPOSITE CORNERS SECURED TO SEE SCHEDULES FOR APPOVED 3 5/8" 25 362 S 125-18 16" 14'-4" 12'-6" STRUCTURE, 9 ATTACHMENT DEVICES.COORD. 24" 13'-5" 10'-10° TWO (2)MAIN MARK DATE --~�� WITH AH FOR SPECIFIC REQMENTS. 20 '� WIT J Q 362 S 125-33 16 16 5 151-6" RUNNER LIGHT I / \\ `��_ UNDERSIDE OF STRUCTURE 24" 14'-9" 13'-6" LATERAL WALL BRACE ---- ABOVE CEILING, CLIPS AT OPPOSITE Z �� LATERAL WALL BRACING 4 FEET O.C., 6" 25 600 S 125-18 16" 19'-9" _ ALTERNATE CORNERS (:. Mill!, 24" 16'-9" ALTERNATE DIRECTIONS TO STRUCTURE 20 600 S 125-33 16" 24'-6" 23'-11" DIRECTIONS TO {? �r�i WHEN REQ'D. 24" 21'-7" 20'-10" STRUCTURE PER ASCE � Z 7-05 SECTION 13.5.8.1 j COMPRESSION POST AT ur�lruurururrulrurunruuuu r►�i�•I dVlrrlrrrnrruurmmr 12 FEET O.C. EACH WAY. V ; ,._ SOUND BATT 4 FEET VALUES LISTED ARE BASED ON STEEL STUD MANUFACTURERS' ASSOCIATION (SSMA)TABLES 52 EACH SIDE OF PARTITION FOR NON-STRUCTURAL COMPOSITE AND NON-COMPOSITE SECTION IN INTERIOR • 0 4. •.) MI o APPLICATIONS(5 PSF)WITH DEFLECTION LIMIT OF 11240. SUSPENDED CEILING SYSTEM 1. VALUES FOR COMPOSITE SECTION REQUIRES MINIMUM 1/2 INCH THICK.GYPSUM c.• 10 Ns- NEOPRENE NEOPRENE FOAM TAPE CONT. BETWEEN BOARD ON BOTH SIDES W/#6 SCREWS AT 12 INCHES O.C. MAX. )( `�►,� SWITCH U BLOCKS ,,0''t GANG 2. g EIGHT LIMITS ARE LESS WHERE GYPSUM BOARD IS ON ONE SIDE. PROVIDE BLOCKING u- . CASING BEAD MI \--c. R STRAPPING ON OPPOSITE SIDE AND USE NON-COMPOSITE SECTION VALUES. f/ \ , 7 F ASTEN RUNNER TO CLG SUPPORT AT 2 CEILING WIRE ATTACHEMENT A� „_ ,� DATE: Ho 01.08.09 FEET O.C.THRU NEOPRENE BLOCKS ,,0 HANGER WIRE AT 45° c� �;” 1 \ q. o F R WAY 1-- CONSTRUCTION TYPE FASTENER FOUR S � JQg; 082681 o Q FILE: 082681-PP id � --'� SOUND GATT WOOD _1/4"X 3"SCREW EYES ( � 0 �� ET WIRE ATTACHED TO MAIN RUNNER, 1 V Z A SAFETY `�� DRAWN: TL GYPSUM BOARD STEEL DECK PRE-DROP WIRES,CMI DC1 OR DC 2 1I4 Ni ��; m >= � CEILING GRID FIXTURE HOUSING METAL DECK SCREW EYES. 4 O w Z CHECKED: SO/SL ,L METAL STUDS,SEE SCHEDULE FOR WRAPPED AROUND FIXTURE Z _ F-- GAUGE,SPACING,AND HEIGHT POST TENSION PRE-DROP WIRES, EMBEDS, 1/4"X 3/4"METAL - . }-- I- HANGING WIRE MIN. FOUR i ft Z CONCRETE HIT ANCHORS TIMES. SECURE AT DIAGONAL O V ►n ' 0.1450 POWER ACTIVATED DRIVE PIN W/1 POURED IN PLACE PRE-DROP WIRES, EMBEDS, 1/4"X 3/4"METAL CORNERS NOT CONTAINING CROSS RUNNER t, 8 �' COPYRIGHT ANKROM MOISAN 1/4 INCH EMBEDMENT AT 3 CONCRETE HIT ANCHORS MAIN RUNNER LIGHT CLIPS. - V ASSOCIATED ARCHITECTS 2006 O, I PARTITIONS TYPICAL BRACING CONNECTION , no , V -.,..... 4 FEET O.C.MAX INTO DECK. REFER TO u;1 STRUCTURAL FOR SPECIFIC INFORM. NOTE:THIS TABLE IS PROVIDED TO GIVE GUIDANCE FOR ALTERNATIVES; FOR OTHER STATES = M LATERAL WALL BRACING: IN LIEU OF NOTE: do ACOUSTIC SEALANT AT SLAB VERIFY WITH AHJ. r. BRACING ABOVE CEILING PROVIDE REQUIREMENTS ARE FOR LIGHT FIXTURES WEIGHING 56LB OR LESS. LIGHT FIXTURES FLOOR PLAN / Q. ® ADJACENT WALL FRAMING FOR LATERAL WEIGHING MORE THAN 56LB TO BE INDEPENDENTLY SUPPORTED FROM STRUCTURE. J C FIN. FLOOR o SUPPORT OF WALL. ', \ \ REFLECTED UNDERCUT DOOR AS REQUIRED TO OUTLETS S WALL CLEAR FLOOR FINISH TYPE RECESS MOUNTEP CEILING PLAN /ci. _ STC 45-49 � WALL LATERAL BRACING 6 LIGHT FIXTURES ' PORT STD. MOUTING HEIGHT DETAILS TO PARTITION WALL Z 1 1/2"=1'-0" IBC-WALL-TYP-B 02.08 T-1:. N.T.S. IBC-WALL-SCHEDULE-02.08 N.T.S. IBC-WALL-LATERAL 02.08 N.T.S- IBC-CLG-SUPPORT 02.08 3/4"=11-0" MTG-HEIGHT , • Q _ Q - c!3 • . ee LN T so 1 o PERMIT PLAN 3 . 17.09 L