Report City of Tigard `DECEIVED q Building Division • 13125 SW Hall Blvd, Tigard, OR 97223 OCT 2 7 Z014 Phone: 503.718.2439 Fax: 503.598.1960 T I GARD Inspection Line: 503.639.4175 CITY OFTIGAHI) www.tigard-or.gov BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System /V151201,-1- 80)c b Property Information Installation Address: 7'. 15 $. J (e& .r(-as+ S+ . City: J i c�,r� Zip: cf o a� Owner's Name: AA0,Acte1 ,01hS Date: Of 77 f IL\ Contractor's Name: 3ek L./Z CCB #: 2_6)i\2_ Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? Ks No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure �' Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow • Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ❑ Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist.docx Is the construction IN material wood and does Yes Type of If"Yes", qualifies for the construction qualify ❑ No Construction the prescriptive path. as "conventional light frame"construction? Is the spacing 24 inches or less? If"Yes", qualifies for Pre-engineered trusses. Yes the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight S Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3)of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. "i of composition shingle. Is the roof mounted S. Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:Building/Forms/Photo Voltaic-Checkl ist.docx • Is the gauge 26 or less? n Yes If"Yes", qualifies for • ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. No inimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? f"Yes", qualifies for I I Yes the prescriptive path. No Attachment of roof mounted Minim 4 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches M. mum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel is less than 18 inches, panels? 18 in •es or less qualifies for the inches prescriptive path. Minimum#10 at •4 inches o/c? Siz= and spacing of If"Yes", qualifies for fastener? El Yes - prescriptive path. ❑ No Is the roof decking of WSP min. 'h"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof . Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PhotoVoltaio.Checkl ist.docx • Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: 5u h Model Number: Listing Agency: TU v It&GS/ � � -v K.F.1.J1o, GS t- (E F5 5 4 I:Bui lding/Forms/Photo V oltaic-Checkl ist.docx SUN POWER E-SERIES SOLAR PANELS i't' t t'd h +rasa Itt- -� ;� , _ HIGH PERFORMANCE & EXCELLENT DURABILITY p 9, -_ N' - �_ I I * - ' ''- '` ,, RECEIVED • 20.4%efficiency Ideal for roofs where space is at a premium OCT 2.1 704 or where future expansion might be • needed. CITY OFTIGARD • High performance E20-327 PANEL. BUILDING INVISION Delivers excellent performance in real world conditions, such as high temperatures, HIGH EFFICIENCY° clouds and low light.''2,3 Generate more energy per square meter • Proven value Designed for residential rooftops, E Series E-Series residential panels convert more sunlight to electricity panels deliver the features, value and producing 36%more power per panel, and 60% more energy per performance for any home. square meter over 25 years- 3 _ HIGH ENERGY PRODUCTION' • — _ — Produce more energy per rated watt ... High year one performance delivers 7-9% more energy per rated — watt.' This advantage increases over time, producing 20% more ii energy over the first 25 years to meet your needs.° Maxeon"Solar Cells:Fundamentally better. Engineered for performance,designed for durability. t 120% Engineered for peace of mind 110% . Designed to deliver consistent, trouble-free , o 1 energy over a very long lifetime.4•5 ti 100% p • 90%% 35%more, Designed for durability a year 25 The SunPower Maxeon Solar Cell is the >. 80% only cell built on a solid copper foundation. W 70% Conventional Virtually impervious to the corrosion and d 60% cracking that degrade Conventional N 50% aiiiiikarthiiiiiiiii4, Panels.4•5 10 15 20 25 • Years #1 Ranked in Fraunhofer durability test.10 0 10% aGr 100%power maintained in Atlas 25+ g Maintains High aytE� PER Power at High Temps F comprehensive PVDI Durability test-" 8% r W 4 m �'r x s No Li hNnduced PHOTON • 6% Degradation poi?F Ei`\E4 Q High Average Watts rn 4% _ _ _i Better Low•Light and P Spectral Response W 2. i High-Performance Anti-Reflective Gloss > 0% sunpowercorp.com SUN POWER E-SERIES SOLAR PANELS SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PRODUCT WARRANTY YU 85' yes, More guaranteed power:95%for first 5 years, Combined Power and Product defect 25 year coverage -0.4%/yr.to year 25.8 that includes panel replacement costs.9 ELECTRICAL DATA OPERATING CONDITION AND MECHANICAL DATA E20-327 E19-320 Temperature —40°C to+85°C Nominal Power12(Pnom) 327 W 320 W Wind: 2400 Pa, 245 kg/m2 front&back Power Tolerance +5/-0% +5/-0% Max load Snow:5400 Pa,550 kg/m2 front Avg. Panel Efficiency13 20.4% 19.8% Impact resistance 25mm diameter hail at 23 m/s Rated Voltage(Vmpp) 54.7 V 54.7 V Appearance Class A Rated Current(Impp) 5.98 A 5.86 A Solar Cells 96 Monocrystalline Maxeon Gen II Open-Circuit Voltage(Voc) 64.9 V 64.8 V Tempered Glass High transmission tempered Anti-Reflective Short-Circuit Current(lsc) 6.46 A 6.24 A Junction Box IP-65 Rated Max.System Voltage 1000 V IEC&600 V UL Connectors MC4 Maximum Series Fuse 20 A Frame Class 1 black anodized(highest AAMA rating) Power Temp Coef. —0.38%/°C Weight 18,6 kg Voltage Temp Coef. —176.6 mV/°C Current Temp Coef. 3.5 mA/°C TESTS AND CERTIFICATIONS Standard tests IEC 61215,IEC 61730,U1.1703 REFERENCES: Quality tests ISO 9001:2008, ISO 14001:2004 1 All comparisons are SPR-E20-327 vs.a representative conventional panel:240W,approx. 1.6 m2, 15%efficiency. EHS Compliance RoHS,OHSAS 18001:2007,lead free, 2 PVEvolution Labs"SunPower Shading Study,"Feb 2013. PV Cycle 3 Typically 7-9%more energy per watt,BEW/DNV Engineering"SunPower Ammonia test IEC 62716 Yield Report,"Jan 2013. - 4 SunPower 0.25%/yr degradation vs. 1.0%/yr cony.panel.Campeau,Z. Salt Spray test IEC 61701 (passed maximum severity) et ol."SunPower Module Degradation Rate,"SunPower white paper,Feb PID test Potential-Induced Degradation free: 1000V10 2013;Jordan,Dirk"SunPower Test Report,"NREL,Oct 2012. Available listings TUV,MCS, UL,JET, KEMCO,CSA,CEC, FSEC 5"SunPower Module 40-Year Useful Life"SunPower white paper,Feb 2013.Useful life is 99 out of 100 panels operating at more than 70%of rated power. 6 Out of all 2600 panels listed in Photon International,Feb 2012. ,...1 7 8%mare energy than the average of the top 10 panel companies tested .■. in 2012(151 panels, 102 companies),Photon International,March 2013. ;■■� 8 Compared with the top 15 manufacturers.SunPower Warranty Review, r 1110 "� Feb 2013. •.. 9 Some exclusions apply.See warranty for details. 11,11 10 5 of top 8 panel manufacturers were tested by Fraunhofer ISE,"PV ■� t Module Durability Initiative Public Report,"Feb 2013. 11 Compared with the non-stress-tested control panel.Atlas 25+Durability 46 mm test report,Feb 2013. 1559 mm 12 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25°C). 13 Based on average of measured power values during production See http://www.sunpowercorp.com/facts for more reference information. For more details,see extended datasheet:www.sunpowercorp.com/datasheets.Read safety and installation instructions before using this product ,clMoy 2013 SunPower Corporation.All rights reserved.SUNPOWER,the SUNPOWER logo,MAXEON,MORE ENERGY.FOR LIFE.,and SIGNATURE ore trademarks«registered trademarks of SunPower Corporation_Specifications included in this dotasheet are sub1ed to rhonge without notice. sunpowercorp.com Documsm N 505813 Rev A/AI UK AUS