Loading...
Report /ST,2c/'- t4r17 Nedwicke Engineering & Design Website: www.nedeng.com Email: infoCnedengineering.com Phone: (503)328-9353 Fax:(503)907-6264 Address: 700 SW Sleret Ave;Gresham,OR 97080 Date: October 30,2014 Mr. RJ Reynolds 13235 SW Howard Drive Tigard, OR 97223 Mr. Reynolds, This memo is in follow up to our conversation on October 29, 2014 regarding Nedwicke Engineering& Design detail 2/S3.R on plan set NED1431-01 dated 08/15/2014. The detail specifies a five ply 2x4 column with a king stud on each side of the column. In addition, 8" SDS screws are specified at 12" on-center on each side of the column. It is my understanding the king stud on the west side of the north column was not installed per plan due to an existing rafter obstruction. However, the screw pattern specified along the length of the column was still installed per plan on each side of the column. The roof rafters on the west side of the beam provide adequate lateral stability for the beam. Therefore, the beam/column assembly is adequate without the king stud in this location. I may be contacted at (503) 328-9353 if you have questions. �co PRO Sincerely, �� t N . PS>O cti �r Ryan Nedwicke, PE, SE / f CON y4N NED` \`) 4 , EXPIRES: 12131/2114 NED1431-01 Reynolds Nedwicke Engineering and Design