Permit CITY OF TIGARD MECHANICAL PERMIT _ " '.: COMMUNITY DEVELOPMENT 1Permit#: MEC2014-00581 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/22/2014 TIGARD' g Parcel: 1S126CB00500 Jurisdiction: Tigard . Site address: 9300 SW WASHINGTON SQUARE RD Project: Macy's Subdivision: FAIRVIEW PLACE CONDO Lot: 20 Project Description: Install(2)exhasut fans and(2)louvers to supply make-up air in stockroom. Contractor: GENERAL SHEET METAL WORKS INC Owner: MACY'S DEPARTMENT STORES INC 11235 SE HWY 212 ATTN:TAX DEPARTMENT CLACKAMAS, OR 97015 7 WEST SEVENTH ST CINCINNATI, OH 45202 PHONE: 503-650-0405 PHONE: FAX: 503-650-1058 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 10/22/2014 $741.41 Class of Work: ALT Type of Const: Plan Review 10/22/2014 $185.35 Occupancy Grp: Occupancy Load: ' 12%State Surcharge-Mechanical 10/22/2014 $88.97 Stories: Project Valuation: $25,475.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: ' Air Conditioning: Heat Pump: Appliances Vent Fans: 2 Vent Systems: Total $1,015.73 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets Other Desc: Duct Work: Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility ■• .- • Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or. rect questions to c NC b ailing 503.232.1987 or 1.800.332.2344. a Issued By: 1 4 ;`/r�� ,, / Permittee Signature: &..... j . Z:3 Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Applica ' r i FOR OFFICE USE ONLY City of Tigard Date/By:Received 4 a-, •. Permit No.: j '/ 35J " 13125 SW Hall Blvd.,Tigard,OR 97 2 ' ' ' III . Phone: 503.718.2439 Fax: 503.598.19600 Plan Review 0-401e/4/1-‘510 l_ 0 r T 4) 2 r' ' Date/By: Other Permit: 51 T-IG A R D Inspection Line: 503.639.4175 Date Ready/By: Juris: ® See Page 2 for Internet: www.tigard-or.gov CITY O f - L Notified/Method: Supplemental Information ll tg nginP TYPE OF COMMERCIAL FEE* SCHEDULE - USE CHECKLIST Mechanical permit fees*are based on the value of the work ❑New construction 'Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and rofit. _ o CATEGORY OF CONSTRUCTION Value:$ �yD� 7B '�S,�T . RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ❑ 1-and 2-family dwelling (Commercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: / / Air conditioning 46.75 Job site address: q 36, ski aa 0 s ,lI l�ix," So R i1 Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: T4 A i cl ► O g q7 ZZ.3 J Furnace 100,000+BTU(ducts/vents) 54.91 JJ Heat pump 61.06 Suite/bldg./apt.no.: Project name: MA,e7,3 f�{t4C A /OOh,AEA'I/ f Duct work 23.32 Cross street/directions to job site: Iii f,/�S 4,..:51,,,, J p NRve /%,�,f/ Hydronic hot water system 23.32 V' ✓ y Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. _ 46.75 Flue/vent for any of above 23.32 Subdivision: Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 / 1 C ) Flue vent for water heater or gas In -IA./1 (2) G I<ha✓r / 44.s ( (2- `bb✓err /b fireplace 23.32 S v p Ip Make V, Gl /1� 1M' 5 lip,/A roe.rh Log lighter(gas) 23.32 / / Wood/pellet stove 33.39 Wood fireplace/insert 23.32 _ Chimney/liner/flue/vent 23.32 _ Other: 23.32 `A Environmental exhaust and ventilation: N PROPERTY OWNER ( TENANT Name: Ma CN f Range hood/other kitchen / � equipment 33.39 Address: y 31" 5IN/ (14,i /o., S6 Ua.,t /4( Clothes dryer exhaust 33.39 City/State/ZIP: l Single-duct exhaust(bathrooms, ` ►q 4✓� 1 2 Z� toilet compartments,utility rooms) 23.32 Phone:($03 ) 6 ZO`�3 311 Fax:( ) Attic/crawlspace fans 23.32 ey APPLICANT IA CONTACT PERSON Other: 23.32 SGl ee¢ M6�FA.-Q 0,,,,- �s Fuel piping: Business name: ( G �A $14.15 for first four;$4.03 for each additional Contact name: L10 tI J tea IV p t t d.. Furnace,etc. . Gas pump'' Z 3 s SE (4 n j ti w 42.12 Wall/suspended/unit/unit heater City/State/ZIP: G IA C-k a t,R g / 0 i2 ( O 6 0 Water heater Phone:(5o ) 650, o it 0 s Fax: :(W) G re • /0, O Fireplace Range E-mail: L ChC Iv.f I" ( 9 SIf7&. coal Barbecue CONTRACTOR Clothes dryer(gas) Other: Business name: .1.4.0 E MECHANICAL PERMIT FEES* Address: Subtotal 4■74/0.18 City/State/ZIP: Minimum permit fee($90.00) Plan review(25%of permit fee) L8$, leg Phone:( ) Fax:( ) State surcharge(12%of permit fee) 8e. eci ' CCB lic.: q0 Igo TOTAL PERMIT FEE '101q. This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tri-County Building Industry Service Board Print name:Ac,(7 Date:ipiZZ, I:\Building\Permits\MEC_PermitApp_040113. c 440-46t7T(Vl/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi-Family Fee Schedule: Total Valuation: Permit Fee: $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional $100.00 or fraction thereof,to and including $10,000.00. 3 14 7, 7 I $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or 3 p fire fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. 47110, 1e Note: All new commercial buildings require 2 sets of plans. l:\Building\Permits\MEC_PermitApp_040I I3.doc 2 I. ,ECEW OCT 2 2 2014 GENERAL SHEET METAL C9TYOF-T D I BUILD SIO1 PROPOSAL Date: REVISED 8/20/14 To: Macy's Attn: Carrie Tuli Project: Macy's - Stock Room Exhaust Fans Note: Approximately 4-6 weeks from approved contract for material. Project duration is approximately 1 1/2 weeks. SCOPE: • Furnish/Install (2) new Rooftop EF's with back draft dampers and interconnect with (2) Rooftop Intake hoods • Includes crane and rigging to lift/set new equipment • Seismic calculations and restraint • Roofing cut and patch, Structural modifications based on industry standard best practices • Low-voltage control wiring between the EF's and intake control dampers • Start-up • Permits/Plan Review EXCLUSIONS: • Electrical, Painting, • Air balance, Night/weekend hours Material $11,212.00 Shipping $196.00 Labor/Subs $14,067.00 Tax $0.00 PROJECT COST $25,475.00 Sincerely, johwv Do-wdi John Dowd Estimator General Sheet Metal Phone: 503.650.0404 ext. 1 1 1 Email: Jdowd @gsmw.com PO BOX 1490, 11235 SE Highway 212, Clackamas, OR 97015 USA V:503-650-0405 F:503-650-1058 CCB# 40163 www.gsmw.com WBE# 3601 k. mccys* INVITATION TO BID Stock Room Exhaust Fans Macy's Washington Square, Store #392 DATE: 07/21/2014 Project Site Address: Macy's, 9300 SW Washington Square Road, Tigard, OR 97223 A pre-bid walk through is required and is scheduled for 7/31/14, 8:30 AM. Meet Don Edgley outside, at Westside of building. Man Door with keypad lock. Bid proposals due 8/13/14 and to be submitted to Carrie Tuli (carrie.tuli @macys.com) Macy's will email further instructions to bid contractors previous to bid due date. Questions regarding the project scope should be directed to Don Edgley (971) 563-6032. don.edgley(a�macys.com. Macy's Capital Project Manager is Steve Olguin, (909) 693-2280 Steven.M.Olguin@macys.com. Base bid shall be for the installation of Two Exhaust Fans as detailed in "Macy's Scope of Work Exhibit A". Work performance shall be governed by "Macy's Scope of Work Appendix A". Duration of Proposed Project, and Lead Time to start the Project is to be included with the Bid Submittal. Bid format. Material Shipping Labor Tax Total Contractor shall submit a 2013 From W-9 and a Certificate of Insurance as specified by Macy's. Macy's Scope of Work Exhibit "A" Install Stockroom Exhaust Fans Macy's Store #392/Washington Square 9300 SW Washington Square Road Tigard, OR 97223 All work will be performed in accordance to this scope of work and the specifications provided. This is to be a complete "turn key"installation, with no extra charges allowed. Excludes any asbestos removal. Contractor is responsible for the following: All required Permits. Includes all Drawings and Engineering required to, acquire the Project Permit from the Authority Having Jurisdiction. Contractor must be licensed, bonded, and approved to perform contracting in The State of Oregon. Protection of Roof System during the project, including removal and reinstallation of insulation blocks. Use Styrofoam as a cushion for any wood dunnage. A Certified Roofing Contractor for the Roofing System shall perform any roofing modifications. The current roof condition has no leaks. All work must be coordinated with District Facility Manager, Don Edgley (971) 563-6032 to minimize disruptions to business. Work shall be performed with all precautions required to ensure no construction dust or dirt infiltrates Macy's Facilities and Merchandise. All work shall be performed in a Neat and Workman-like Manner. District Facility Manager, Don Edgley will be the final determination of this standard. Modification of any existing doorways or installation of any new doorways required to remove and install components. Complete build back to original condition any building modifications required to complete the installation. Smoke evacuation during demolition. A "Hot Work Permit" is required for any Burning or Welding, including an Active Fire Watch. "Hot Work Permit" to be provided by Macy's upon Contractor's request. Jobsite is to be left in a "clean as it was originally" condition upon completion of work. All scrap, misc. materials, garbage to be properly disposed of off-site. All modifications to the existing building systems required for correct installation. Roof Entrances and Access are to be secured each night. Electrical Wiring is excluded from the Project scope and performed by others. Furnish and Install Two Greenheck GRE GB30015, 8,500 CFM, .1 SP, 1.5 HP(480 Volts 3 phase) Roof Mounted Exhaust Fans. Complete with back draft dampers Include field installed motor disconnect (provide for the Electrical Contractor). Furnish and Install Two Roof Mounted Air Inlet Hoods, Type Greenheck, Style GRE FGI 40 /40 with 120 Volt or 24 Volt AC Motorized Damper Actuator. Actuator operation will be energized to open and spring return to close. Hood duct size will be calculated and sized to ensure the volume of inlet air matches the exhaust fan CFM. Roof Curbs for mounting and associated roofing modifications required for installation of the Fans and Hoods. Roofing contractor must be Certified for the Roof System. Any Crane use must be performed before 8 AM and coordinated with District Facility Manager, Don Edgley, and The Mall Management. Actual specific location of the Fans and Hoods will be determined by structural requirements and decided at the time of construction. Structural Modifications required for Installation. Installation will be performed using a day shift. Normal access to the building is available at 6:00 AM. Project " /-1l i s R VO TD F 1$M( A KIT-046- By CC. F Sheet No. I / r! r Vii l , Location-�"ict,AgDi OR Date 11�+�W) ,. ,r 'rf,.., Consulting Engineers. t Client * . f#- Revised Job No. Portland.Oregon 214543 3 Dote — — — n DrK ?1 LWir -- -�°�-- 1` rf. ,\ni5/ _.-re:,(.0 7izLass GoNIJ4G71c'lJ ro MArcr-! F-7—(o lTZt t5s pa nJEL //STS 6 t 1 (4r43'' c. ) / .L , >1✓ t s,. 27 4 ilirtigcx F ExiLiAc rsr A CU Ria, r! Ai (4+-11=Ld Your" ■ 1EW 6/-)[TORT /40 I ! 7 AT o11-1 FAN/ J`5 E-J-- �r 3Cv- 1 j> 'p' t L.ex4.-!P/4..� �•j L3x3) Y'4- fl ? T'?F 6 V LaUVEd I A-L i CAN S7"F t-.. ! , 7L '7�(t7 w�MIL Cu 113 ,E)e--61- s wit t4 fl ( OP() N & Rf3, co/Jr-R..46.7DR _. CoC5RPi)JAr . ) Y i � ` (cuR�i?M 1t : . (F)(n/r61 lr 1 • 3 ,7%rlcrrtr -L.Aio-rEs : 147 011 j 2. fi &RIFyA«. xrsills1C-r A1l.4 r s/ "/ pR)cV ry e ♦"o 42 p TZlL IAJC,-/ 1/.Ia1c.4T16?hi / ----, 3, ALLSit L.AAJGLEs'r-©, .L:.A L,e,...7EE`L , L'/E41 lMEr~ co Ea I p`Ctit L 5 re, 421 7C> 4 13 9 Po AlorCc.t7- _xlsrrA16 ..,cisrs,ex-Cc-5 B AcE.s 6)19 ON �s. v.5. pxcv/v=--pE,erv1:--/c-..spEc(A _/nlsj'7TL A)/+T' ' E S; 12-31-i . /t1ELLD We-I- s 6, ExIS'r=7'.16r icc?�ii,1 G A.J..,:tE t>R 00F/46-- 'g:P t.1k1:‘ '`rd c-ir;31 s 7 .7,a,,,Grccd7-ece)F?>.Erk". i4vz"i a. 7 t i /..,5 Ha CoMr,LE474°1,4 B, sr==ter r-Avs 1.,t r5.'r- >a i-tier! t Frxx (.16c g 333=) SK-1 Roo FAQ LOLL V E R LIN I SU"-aer F ICI G- -L4t/ NT$ Sheet No. Project I'llACYS RDOFTC>P FArA ploGairiK1cx By CC1-- k 1" 69 It' 4g .— L MGARJ2, OR Dote roleWiLi' •, - • • .....4u!..,:.:;„.,.:y Consulting Engtneers ocation Client ,::;•/.:w.ER4 L.L'Ilra5-4-ME-1141.--- Revised Job No. Portland,Oregon 2/4543 Dote --- T S E,. Rr....r-z- 1, -- -- /ref, • / , Ex1.5.-Okler . / ,.,,-- ROOF,M14‹..5FF- CD Fog- . / Arm CPI 1-1---...-1 Jr . . . 1 II 1.1 A (E)1-k1Js.5._ Top• ihrt. : L .,< ,_S-rE.- __.cc,Arni.,e-c 7ri,n4v 70 CE-)77-Li.s,STpe-Ho/z,t,7a --:' 23 .v,./117-1/A4 60"rcs 7,4,,,/z-,,e-re /NIT "3 ia 1171' Li . s---7--. - • • .3„ft, r.11 / 6mill A.,,,,LE C&•1.11.1 EC:1-701-4 ATS, • (--) • .....- fiEv4 F,i7cf- FAA _ _.----- (OR 1\)E\Ai LLVI,1 0 1..;41.146t-i vi EIJI- L____Th cti: my):1Appg.:. 13 44 —----------11 . VV/Iiri C,-5CgelAS 4art s".=>4. -bg 4-1— ,-/-,- ---(E)F---60r4 A1C-r/FLA.S.LtixICT N I-. -4 \ CT Up.,,it Arw i ...... , A T'A c H NM-C U.F E s.-r n L X?:, v./ tr /- ' 1100 • - .) -..sw.5 Arr E.641-1.c-4,g7,/eiz Atar-----A-7- 6 cc:. - A:Ro ,A N ici) i o k -taT ' • 49,9 0 ±1T1 ) KooF. -F,Am /1-01-1VEle- SO PPORT-Fp.AmiNG-DETAft_s • ®( fConsultin 9 En ineers f October 22, 2014 Mr. Lloyd Campion General Sheet Metal 11235 SE Highway 212 Clackamas, OR 97015 RE: Macy's Store Rooftop Exhaust Fan and Louver Unit Support Tigard, OR Dear Lloyd: Attached please find calculation sheets 1 through 20, dated October 16, 2014, which verify the structural adequacy of the new rooftop fan and louver unit support, as shown on sketches SK-1 and SK-2 dated October 16, 2014. Design is based on the requirements of the 2014 Oregon Structural Specialty Code (OSSC), based on the 2012 International Building Code. If you have any questions or need further information, please call me. Sincerely, Chris Tung, PE, S , EED AP Associate se L C T p� QD PRO L Attachments X42 CT:ch 214543/calc_letter_102214.doc CyIrEG( �ADLY k1 i .,X S: 12-31- !'/ 111 SW Fifth Avenue, Suite 2500 Portland, Oregon 97204-3628 (503) 227-3251 Fax (503) 227-7980 Seattle Everett Tacoma Lacey Portland Eugene Sacramento Grass Valley San Francisco Walnut Creek Los Angeles Long Beach Pasadena Irvine San Diego Boise Phoenix St. Louis Chicago New York / Sheet No. t■ - ''.._.,1 r__ ,;,:,., Project MA Or Ro ,T , 1...0.41, 4stit_ By etr 7 Location TI ,OK, Date al.:.,11., Consulting Engineers Client eiv,,,07..ALSFOTIVIEJAL Revised Job No. Portland.Oregon 2/e72.Szli.. Date . ■ I , . .ga9f- h*t.fq 0 Kilt-itiDEMP : • PKC)164.Ft.R I .1b./4 0.5.--- -./A 5 C•C 'HO 1 i , I ! (-0V■I 5E0;1 -44 / 4 ';4'l\I Li Mir V\tr 23-1 IAEA-VIES-T.1 LoqVER VVE../6HIS 50'.±..-olvLiy) -i- 6,4A.ri3,1 8,... t-41 .c. 4,-664, • u•N 1 _ , 4# i — g•cor -R0,4Dva) ,_z__- 2-1-5 1 .. I A 1 \ \ t . (_ ,) •00P. Pt- :- )5 1*1 • ' Siq i ow : 25 ev IF*/ 0-45ce(E'Plf.rj5,cF-rgcl- Es 1 . . . -- _ itt ) 1 I ..i C ) IN ,074 , i 0:15......spiis ------- - ---It , H 5 I , c) 1 I , 0 -.- --- - H 1_ M,T\ .-•.-6,44 ig I 7/ Ar vill fAtAs i i i / r„ Tr? ,,1 /1----:--- e).3 .\,,(i. 2 .o,3l.5.,psLyAlf, c,r(- ,spAct4,6r. I _ .......... VIVED LoAD__ : '12o_impl.4_Exr, e) ,1o.i 0.A14.1,frvc-r. _i_ev.-si___) 1 I - 0,oc,2,5 x 0-.1G x [.o X o.55xFe--= 23 i,8 tsF i i 1 x _-_-_-_-_ 4-67 14,6 . 6).17--/eaLls„„v. L-Eis-"Ic , [ 1---0A-1). I,/_--_-_- z.3,23 x 1.._, x. ricF- = ..1-2 , tr 1 1 ---- -------+-- --- 428- -- i - 1 , I II I, tibl Avpi_.'DoOARD O., '41‘,--rqss (Asp). i 4 I i 2.77/2. -+ 4,0--if<2/7'A,6) —I --f28/2//..(0 I 1 -.7: 2/1 0 + 1 __ _ a ,, o • , ir 1 / ' / _I L 0, ( t`I ' ' I V VIZI69,Mt- z---- --1-)( -7 tx( -.1-05.)x.ZI5)::._- 21 c;)5 , 1- ,1/ , 6 1 1 1 0 t)rRns 38 % c3I‹ 1, / .1P 15 i-2-5)>‹, 2-Tiz --' 35c3C2 VB1v)= -2.1o>(24. , ._=__ fG&41i 1 -1- [ .., 0, I . . \./Apnr.117),/vcsrz.t 6Ii■IAL.=-___- 0 alei'66 ; C, 5 la I, R Sheet No. Project frIAC Ys Top 7,N Fs s LFFDF y CO- -., ., _A I(. ® ft Location Consulting Engineers Date I 0/6/14 Client Revised Job No. Portland.Oregon 2/eyig-1/3 U . Date t . i t . . . - • . . - VOX, Gt,r1/OPP LL/A-r)- • = "-FRI E>RPOF PI-- --i 3.(-1 Ix Is r_sr :_-_ z-2c. t- 01,- EN)cri,t -re) 11 oLl> DOW&.1 '/AN ir VV/6 NJ Er r tAirl-rPi 1 I 1 0 , The c-pw_ip um'ir Wetwrs Idlo_ 461H M6rt&L6,1_3): Es16-N1 W445!III' tilDP. - 'HAN 5YD r4R. 2414 OSS-4 34-03, 1 I • ! 1 I t I / _.., 2, ,,D.,E57 67t4 A r-24?-1/&16— i 215 kal.tXiltlX(i5X1.24-25)</,(2 --=-- 112 17 KA/ F. dl ...= (-)-, V Vut------ -4141)c 2' -r1-12fx 11-1 013-h-1,_-_- I 4 4., 40(. 114 0 1 _.*_ ,__, i 1 VLA 1 141 (-`146,y\ ---- 1712--t -16-1 x 2/-7 --,---- } L. xy.,., 0 ...ELT d-.. riirl f. j _.i = 87. -------------, Lb.,EA-I, * It ,---- 3(,xil 0.5 .1 ---,-- 2,D.s. i -.0,■ -i-- cnAisElzvirnvE..- —, 4,C.E.P I I I _ . 1.- c Vi.k- ok I i i I 6,1\314 c:rioki e..CE)7u5 5, 1 .... -1- V(4.7-:,_0 ..21?/?' I 1 .--' Fr v\/it___ _,(1,,›<_16-1,e 4-zY.1g> i- ,e Z ..--- 12,S- >>14,_ ok ---/ , : 4 ! ! i ?z „ 1 r—I-ir I i 5 41,7 Il Z. i 4 I ii(3- ,6(.•24 -) =----- 0 032,11 .?„ 1. - 1,,,,, 2-e-f-.)<- jc,00 K 1.23 - I 1 0 .. , au i-er>-1-c,....9rL.it-,A,-J5T- A ..F...R — MILT, le.v.si Il< 0),,,,,„„x• • 4,1 Z.0,_...„4,c,vpijER 1 ‘#, 1 m...FLIF-r- 84 412. 4. 7 6k47,,Ac-ilY 1G65 Tr--/4stal d, 1 si-FAR .40114/4 At 1'2- A637 6,6FAct-rf .4 -1* .5ymAg I. ir I I d-- , _ I--i - , 1 1 1 e, li 'i 11 2.j Project OAc.8 Rvap TUT anis Sheet No.. By 661-- 74 77":11 Date le-t--, Location tv L/ • .4 . , Consulting Engineers Job No. Client Revised Poriland.Oregon 2/41-5i43 Date ___ . ' -----efrif:7C,4.:- /-1/C..MAS5 Z-Viir4T7C5/4 1:, 05SL. t-71.- . i . ! . . . . AiEtni tiklil k.k7. . , 1 : . , , 1 , . . , , . y. , 0,6)/2,c- f-: MASS; --. 7/00,..S x /5 1)..5F- _-_-..' /35 00,( ' / I : , 1 / X LI H/7-7 AJ , 34i494e,e/ . . i : . : 1 : : . , . i , , • .,, : — . : : . , . • . . : , , 1, . . . . , , . , . . , 1 . . ! i . , . . . 1 . , . . . : . : . . . , . . . , , . , . , . . . . : . . . „ . . , . . , .• . i . . . . I , .• : . . . . ■ . . , ! . , t „ 1 Design Maps ummary Keport Page 1 of 2 `' . a t 11.l 1 , Design Maps Summary Report User-Specified 'Input Report Title Macy's Washington Square Roof Fans Fri October 3, 2014 18:00:19 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 45.4517°N, 122.7813°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III ;I -Z>"; Ta.,, ' °.byres_..: tl41,,,— 5 i0:., iis' 2..,,il,°" 1 5000ni;- i :Cedar 1=lills-w. �'z' �t-.. l, .`P'"�=.���.. : 9, - 3", e ' • ' ±i'' i,� SL's': ���¢ > �6`. 4'"a ,3/u" - li%, A 4=v AIOl7 .d �.. - F J 1: ''i•s ,a - r+ f 6 .:•y. .$. • - ;;;;_,-,..k.,,„ ! Vii]},':"-�by`.`,?�': ,.f s� ': ,y i,a ?g.: f"+S' l: I f r- w# <{t.- s t 1C1 ;gs `GSPdtf Hoiiic Wbitdord,v ir=1.: r,'_, a0 pyxT.`<r'.�".�,�` �}'°-` `"r'., Tai-T z. �-" t � r _i $;qjç..li: �tt'G, " i `, ,,tr" .:f it- 5.? sGC '4" 67-,y4:0,,,3r"glzIfe t, --.'.,,--17.4:n,'"e,-',g- n .A:-.- '` .,`tS'( 'F�. ^� �c,� -,•,i (� 3• '1 a ✓ fs Gf & r A a'l r'` , ,,04.;,::14,0.=A,7,,,,,,11 ^`iJ O:.F '(,t xH.17447. 4.1f. I tT -. :1fr m .' evt"'twe,.pr- v'C=-_• d}1° ,P'+ r L F m _ � ., s�p''n'„r r* ..( -" ,i`4*. :44%,-I ,G y i}x s'x i .', %:'r;. ,�5,,z,y==�',,1�;' i:, ;t:ve�e,,i=^�Y4ii„, ti,„. i r� kittF`� E3”--�•? ;:f` . w ..ex ^,'rTk,„,., . . /'��e -�Y.k` Y�kn 4w`- � i mi~1�r µ�,f� ;Y�"\Y�^�� ,iw '. `i:� � �,y'l.', [�7 /,3+�""' . SFr MId a, .-r cN .q;=1 3:?, `„i�;' or. °:s:,�d.:4,eTf- -+- 1 -1 �2-fs'r.i- .? :4 `K{ flYlg,� R " , 'M .” r xt'#.Frxs-wt=eO.s:„. '"= e,^5; .°sZ. -� 1 .t':i lm` -"-aei;`y '?i 4.1;n/1`e. :,'-',.. 111.,,,,,,,-,14 1 i '`T4;;,,,:+d.^:ex ,:,^'' x '`� 'a x 1 ^,<,.,.i;, ��;, ice' .":' cf,, '�a�.;,;'rji:,' 'F ✓ ms's IY, t .: ',,{r-'1- .,,i;457:,-,:c '- v r�mapquesztt,i: ff L asti,1 ®20141 . . . ®M1tV, ,,, t,. USGS-Provided Output Ss = 0.979 g SMS = 1.085 g Sos = 0.723 g S1 = 0.425 g SM1 = 0.670 g S°1 = 0.447 g For information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP" building code reference document. MCER Response Spectrum Design Response Spectrum 0.00"' 1.10 0.70 ! 0.55 0,;2 0.07 t.g4T • 0.77 0,SG T SA 0.55 n 0-40.L IV 0.55 L 0-d0 0.44 0.72 0.33 0.24- 0.2_ 0.16 I 0.11 0:00 0.00 0.00 ! t I I I I 1 0,00 0.20 0,40 0,60 0,00 1,05 1.20 1,40 1,00 1,00 2,07 0.00 0..0 0-40 0,60 0 00 1,00 1.20 1.40 1.60 1,00 2.00 Period,T(sec) Period, T(sec) For PGA,, T1, CRS, and CR,values, please view the detailed report. http://ehp3-earthquake.wr.usgs.gov/designmaps/us/summary.php?template=minimal&latit... 10/3/2014 4 q I ,,,b„ '�.- CC EVAEUATION1 ,R 4 ��t y , ter. � � ,1.-,44,. ,� �i , �; � � x �� '. O ICE . .4�- � >�4- Mos =Widely°Accepted and Tr ed ICC-ES Evaluation Report ESR-3332 • Reissued October 1, 2013 This report is subject to renewal September 1, 2014. www.icc-es.orq I (800)423-6587 I (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 05 00 00—METALS J429 Grade 5 screws and the hardness limits for ASTM Section: 05 05 23—Metal Fastenings A449-10 Type 1 screws. The threaded portion of the screw with the lower hardness is considered the load-bearing REPORT HOLDER: area, used to transfer loads between connected elements. See Figures 10, 11 and 12. Table 1 provides screw INFASTECH DECORAH LLC descriptions (size, tpi, length), nominal diameters, head ELCO CONSTRUCTION PRODUCTS styles, head diameters, point styles, drilling capacities and 1302 KERR DRIVE length of load-bearing area. DECORAH,IOWA 52101 3.1.1 EDX445 (Type 1): The EDX445 screw is a #10, (800)435-7213 coarse threaded screw with a phillips pan head. See www.elcoconstruction.com Figure 1. infoElcoainfastech.com 3.1.2 EAF430, EAF460, EAF470, EAF480 (Type 2): EVALUATION SUBJECT: These screws are #10, coarse threaded screws with an indented hex washer head. See Figure 2. DRIL-FLEX®SELF-DRILLING STRUCTURAL FASTENERS 3.1.3 EAF621, EAF641, EAF681, EAF690, EAF715 (Types 3 and 4): These screws are#12, coarse threaded ADDITIONAL LISTEE: screws with an indented hex washer head. See Figure 3. HILT!,INC. 3.1.4 EAF755(Type 5):The EAF755 screw is a#12, fine 5400 SOUTH 122ND EAST AVENUE threaded screw with an indented hex washer head. See TULSA,OKLAHOMA 74146 Figure 4. (800)879-8000 3.1.5 EAF816, EAF841, EAF846 (Type 6): These www.us.hilti.com screws are 1/4-inch-diameter, coarse threaded screws with PRODUCT NAME:KWIK-FLEX®SELF DRILLING SCREWS an indented hex washer head. See Figure 5. 1.0 EVALUATION SCOPE 3.1.6 EAF865, EAF876, EAF886, EAF890 (Type 7): These screws are '/4-inch-diameter, fine threaded screws Compliance with the following codes: with an indented hex washer head. See Figure 6. e 2012, 2009 and 2006 International Building Code®(IBC) 3.1.7 EAF888 (Type 8): The EAF888 screw is a 1/4-inch- • 2012 and 2009 International Residential Code®(IRC) diameter, fine threaded screw with an indented hex washer head. The lead threads have a design identified by the Property evaluated: manufacturer as Round Body Taptite.See Figure 7. Structural 3.1.8 EAF900, EAF910(Types 9 and 10):These screws 2.0 USES are 1/4-inch-diameter, partially threaded, fine threaded Elco Dril-Flex® and Hilti Kwik-Flex® Self-Drilling Structural screws with an indented hex washer head. Fasteners are used in engineered connections of cold- 3.1.9 EAF940 (Type 11): The EAF940 screw is a 5/16- formed steel members. The fasteners may be used under inch-diameter, fine threaded screw with an indented hex the IRC when an engineered design is submitted for review washer head. The lead threads have a design identified by in accordance with IRC Section R301.1.3. the manufacturer as Round Body Taptite®. See Figure 8. 3.0 DESCRIPTION 3.1.10 EAF960, EAF970 (Type 12): These screws are 3.1 General: 5116-inch-diameter, fine threaded screws with an indented hex washer head. At the lead end of the screw, the shank Elco Dril-Flex® and Hilti Kwik-Flex® Self-Drilling Structural of the screw is notched to form a shank slot. See Figure 9. Fasteners are proprietary, self-drilling tapping screws that have a dual heat treatment and that are coated with a 3.2 Screw Material: corrosion-preventive coating identified as Silver Stalgard®. The screws are formed from alloy steel wire complying with The drill point and lead threads of the screws are heat- ASTM F2282 Grade IFI-4037. The screws are heat-treated treated to a relatively high hardness to facilitate drilling and to a through-hardness of 28 to 34 HRC. The drilling point thread forming. The balance of the fastener is treated to a and lead threads are heat-treated to a minimum of 52 lower hardness complying with the hardness limits for SAE HRC. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed >r WWI an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as r1 to any finding or other matter in this report,or as to any product covered by the report. amccc Copyright©2013 Page 1 of 6 5 o M ESR-3332 I Most Widely Accepted and Trusted Page 2 of 6 3.3 Connected Material: member of the connection. The drilling function of the The connected steel materials must comply with one of the fastener must be completed prior to the lead threads of the standards listed in Section A2 of AISI S100 (AISI NAS for fastener engaging the metal. When the total connection the 2006 IBC) and have the minimum thickness, yield thickness exceeds the maximum drilling capacity shown in strength and tensile strength shown in the tables in this Table 1, clearance holes must be provided in the attached report material to reduce the thickness to be drilled by the screw. p Clearance holes must be 13/64, 15/64, 17/s4 and 21/64 inch(5.2, 4.0 DESIGN AND INSTALLATION 5.9, 6.7 and 8.3 mm) in diameter for #10, #12, 1/4-inch- 4.1 Design: diameter and 5/15-inch-diameter(4.7, 5.3, 6.4 and 7.9 mm) Elco Dril Flex® and Hilti Kwik Flex Self-Drilling Structural fasteners, respectively. The screw must be installed perpendicular to the work surface using a 1,200 to 2,500 Fasteners are recognized for use in engineered rpm screw gun incorporating a depth-sensitive or torque- connections of cold-formed steel construction. Design of limiting nose piece. The screw must penetrate through the the connections must comply with Section E4 of AISI S100 supporting metal with a minimum of three threads (AISI-NAS for the 2006 IBC). Nominal and available protruding past the back side of the supporting metal. fastener tension and shear strengths for the screws are shown in Table 2. Available connection shear, pull-over 5.0 CONDITIONS OF USE and pull-out capacities are given in Tables 3, 4 and 5, The Elco Dril-Flex® and Hilti Kwik-Flex® Self-Drilling respectively. For tension connections, the lowest of the Structural Fasteners described in this report comply with, available fastener tension strength, pull-over strength and or are suitable alternatives to what is specified in, those pull-out strength, in accordance with Tables 2, 4 and 5, codes listed in Section 1.0 of this report, subject to the respectively, must be used for design. For shear following conditions: connections, the lower of the available fastener shear strength and the shear (bearing) strength, in accordance 5.1 The fasteners must be installed in accordance with with Tables 2 and 3, respectively, must be used for design. the manufacturer's published installation instructions Connections subject to combined tension and shear and this report. If there is a conflict between the loading must be designed in accordance with Section E4.5 manufacturer's published installation instructions and of AISI S100 (AISI-NAS for the 2006 IBC). Connected this report,the more severe requirements govern. members must be checked for rupture in accordance with 5.2 The allowable connection capacities specified in Section E5 of AISI S100. Section 4.1 are not to be increased when the The values in the tables are based on a minimum fasteners are used to resist short-duration loads, such spacing between the centers of fasteners of three times as wind or seismic forces. the nominal diameter of the screw, and a minimum 5.3 The utilization of the nominal connection capacities distance from the center of a fastener to the edge of any contained in this evaluation report, for the design of connected part of 1.5 times the nominal diameter of the cold-formed steel diaphragms, is outside the scope of screw. See Table 6. When the direction to the end of the this report. connected part is parallel to the line of the applied force, 5.4 Drawings and calculations verifying compliance with the allowable connection shear strength determined in this report and the applicable code must be submitted accordance with Section E4.3.2 of Appendix A of AISI to the code official for approval. The drawings and S100(AISI-NAS for the 2006 IBC)must be considered. calculations are to be prepared by a registered design When tested for corrosion resistance in accordance with professional when required by the statutes of the ASTM B117, the screws meet the minimum requirement jurisdiction in which the project is to be constructed. listed in ASTM F1941, as required by ASTM C1513, with 6.0 EVIDENCE SUBMITTED no white corrosion after three hours and no red rust after twelve hours. Data in accordance with the ICC-ES Acceptance Criteria 4.2 Installation: for Tapping Screw Fasteners(AC118), dated June 2012. Installation of Elco Dril-Flex® and Hilti Kwik-Flex® Self- 7.0 IDENTIFICATION Drilling Structural Fasteners must be in accordance with The Elco Dril-Flex®and Hilti Kwik-Flex®self-drilling tapping the manufacturer's published installation instructions and screws are marked with a " ' on the top surface of the this report. The manufacturer's published installation screw heads, as shown in Figures 1 through 9. Packages instructions must be available at the jobsite at all times of self-drilling tapping screws are labeled with the report during installation. holder or listee name (Elco Construction Products or Screw length and point style must be selected by Hilti, Inc.) and address, product brand name (Dril-Flex®or considering, respectively, the length of load-bearing area Kwik-Flex®), product number or item number, size and and the drilling capacities shown in Table 1. The fasteners length, point style and the evaluation report number must be installed without predrilling holes in the receiving (ESR-3332). A ''' , -iESR-3332 I Most Widely Accepted and Trusted Page 3 of 6 CO TABLE 1-ELCO DRIL-FLEX SELF-DRILLING STRUCTURAL FASTENERS DRILLING LENGTH OF ELCO DESCRIPTION NOMINAL HEAD CAPACITY LOAD SCREW HILTI ITEM HEAD POINT TYPE PRODUCT NUMBER (nom.size-tpi x DIAMETER STYLE' DIAMETER STYLE (in.) BEARING NUMBER length) (in.) (in.) AREA2 Min. Max. (in.) 1 EDX445 03409732 #10-16x3/4 0.190 PPH 0.365 2 0.11 0.110 0.38 EAF430 00408123 #10-16x3/4 0.190 IHWH 0.399 3 0.11 0.150 0.38 EAF460 03489672 #10-16x1'12 0.190 IHWH 0.399 3 0.11 0.150 1.00 2 EAF470 03458234 #10-16x2 0.190 IHWH 0.415 3 0.11 0.150 1.50 FAF480 03492651 #10-16x2'/2 0.190 IHWH 0.399 3 0.11 0.150 1.83 EAF621 00087572 #12-14x'/8 0.216 IHWH 0.415 3 0.11 0.187 0.38 EAF641 00087646 #12-14x1 0.216 IHWH 0.415 3 0.11 0.187 0.50 3 EAF681 00087647 #12-14x1'12 0.216 IHWH 0.415 3 0.11 0.187 1.00 EAF690 00008595 #12-14x2 0.216 IHWH 0.415 3 0.11 0.187 1.50 4 EAF715 03011177 #12-14x3 0.216 IHWH 0.500 2 0.11 0.110 2.35 5 EAF755 03458235 #12-24x13/4 0.216 IHWH 0.415 5 0.11 0.500 0.80 EAF816 00087648 '14-14x1 0.250 IHWH 0.500 3 0.11 0.210 0.45 6 EAF841 00087649 1/4-14x1'/2 0.250 IHWH 0.500 3 0.11 0.210 0.95 EAF846 00008598 '/4-14x2 0.250 IHWH 0.500 3 0.11 0.210 1.45 EAF865 03011203 '14-20x1'18 0.250 IHWH 0.500 4 0.11 0.312 0.50 EAF876 00000451 1/4-20x1'12 0.250 IHWH 0.500 4 0.11 0.312 0.83 7 EAF886 00000452 '/4-20x2 0.250 IHWH 0.500 4 0.11 0.312 1.33 EAF890 00010436 '/4-20x2'/2 0.250 IHWH 0.500 4 0.11 0.312 1.83 8 EAF888 03458236 '14-20x13/4 0.250 IHWH 0.500 5 0.11 0.500 0.80 9 EAF900 03414194 '14-20x33/8 0.250 IHWH 0.500 3 0.11 0.210 2.70 10 EAF910 03463594 1/4-20x4 0.250 IHWH 0.500 4 0.11 0.312 3.50 11 EAF940 03011230 5/,6-18x1'12 0.313 IHWH 0.600 3 0.11 0.312 0.80 EAF960 03006009 5/,6-24x11/2 0.313 IHWH 0.600 4 0.11 0.312 0.80 12 EAF970 03432628 5/,6-24x2 0.313 IHWH 0.600 4 0.11 0.312 1.25 For SI: 1 inch=25.4 mm. 'Head styles:IHWH=Indented Hex Washer Head;PPH=Phillips Pan Head. 2The Length of Load Bearing Area is based on the length of the threaded portion of the screw that is heat treated to HRC 28-34,and represents the limit of the total thickness of the connected elements. See Sections 3.1 and 4.2 and Figures 10 through 12 for further clarification. TABLE 2-FASTENER SHEAR AND TENSION STRENGTH,pounds-force''2.3 NOMINAL STRENGTH ALLOWABLE STRENGTH(ASD) DESIGN STRENGTH(LRFD) SCREW SCREW (TESTED) 0=3 0=0.5 TYPE SIZE Shear,Ps, Tension,P,, Shear,P„/O Tension,P,JK2 Shear,CPss Tension,QPu 1 #10-16 1526 2273 509 758 763 1136 2 #10-16 1463 2276 488 759 732 1138 3,4 #12-14 1992 3216 664 1072 996 1608 5 #12-24 2503 4177 834 1392 1252 2088 6 1/4-14 2692 4363 897 1454 1346 2182 7,9,10 '/4-20 2659 4729 886 1576 1330 2364 8 '/4-20 2617 4619 872 1540 1308 2309 11 5/16-18 4568 8070 1523 2690 2284 4035 12 5/,6-24 5471 8757 1824 2919 2736 4379 For SI: 1 inch=25.4 mm,1 lbf=4.4 N. 'For tension connections,the lower of the available fastener tension strength,pullover strength,and pull-out strength found in Tables 2,4 and 5,respectively,must be used for design. 2For shear connections,the lower of the available fastener shear strength and the allowable shear(bearing)capacity found in Tables 2 and 3, respectively,must be used for design. Nominal strengths are based on laboratory tests. ESR-3332 I Most Widely Accepted and Trusted Page 4 of 6 TABLE 3-SHEAR(BEARING)CAPACITY OF SCREW CONNECTIONS,pounds-force''2'3'4,6 SCREW SCREW NOMINAL DESIGN THICKNESS(in.)6 TYPE DESIGNATION DIAMETER (in) 0.048-0.048 0.048-0.075 0.060-0.060 0.075-0.075 '/8-3118' 3/16"71/4" 1/4.'-0.105" ALLOWABLE STRENGTH(ASD) 1 #10-16 0.190 289• 289 404 - - - - 2 #10-16 0.190 369 395 453 - - - - 3,4 #12-14 0.216 356 573 513 497 - - - 6 '/4-14 0.250 377 626 520 661 638 - - 7,8 '/4-20 0.250 3867'8 5267'8 5338 6706 5959 6249 5549 11 5/16-18 0.313 408 622 561 891 - - - 12 5/16-24 0.313 - - - - 1347 984 887 DESIGN STRENGTH(LRFD) 1 #10-16 0.190 433 433 605 - - - - 2 #10-16 0.190 590 631 724 - - - - 3,4 #12-14 0.216 569 917 820 795 - - - 6 '/4-14 0.250 603 1001 833 1058 1021 7,8 1/4-20 0.250 6177'8 8427'8 8528 10728 9529 9999 8869 11 5/16-18 0.313 653 996 897 1425 - - - 12 5/16-24 0.313 - - - _ - 2155 1575 1419 For SI: 1 inch=25.4 mm, 1 Ibf=4.4 N,1 ksi=6.89 Mpa. 'Available strengths are based on laboratory tests,with safety factors/resistance factors calculated in accordance with AISI S100. 2For shear connections,the lower of the available fastener shear strength and the available shear(bearing)capacity must be used for design. 3Values are based on steel members with a minimum yield strength of F,,=33 ksi and a minimum tensile strength of F.=45 ksi. #Available capacity for other member thickness may be determined by interpolating within the table. Sunless otherwise noted,when both steel sheets have a minimum specified tensile strength F„Z 58 ksi,multiply tabulated values by 1.29 and when both steel sheets have a minimum tensile strength F„z 65 ksi steel,multiply tabulated values by 1.44. 6The first number is the thickness of the steel sheet in in contact with the screw head(top sheet). The second number is the thickness of the steel sheet not in contact with the screw head(bottom sheet). •'When both steel sheets have a minimum specified tensile strength of F„z 55 ksi'(e.g.ASTM A653 SS Grade 40),multiply tabulated values by 1.22. BWhen both steel sheets have a minimum specified tensile strength of F„Z 52 ksi(e.g.ASTM A653 SS Grade 37),multiply tabulated values by 1.15. Wien both steel sheets have a minimum specified tensile strength of F„?58 ksi(e.g.ASTM A36),multiply tabulated values by 1.29. TABLE 4-TENSILE PULL-OVER CAPACITY OF SCREW CONNECTIONS,pounds-force''3.4'5'6 MINIMUM DESIGN THICKNESS OF MEMBER IN CONTACT WITH SCREW HEAD SCREW SCREW NOMINAL EFFECTIVE (in.) TYPE DESIGNATION DIAMETER PULL-OVER (in.) DIAMETER 0.048 0.060 0.075 0.105 118' 3/16' 'li' 6116' (in.) ALLOWABLE STRENGTH(ASD) 1 #10-16 0.190 0.357 386 4812 4812 4812 4812 - - - 2 #10-16 0.190 0.384 415 4812 4812 4812 4812 - - - 3,4 #12-14 0.216 0.398 430 537 672 7342 7342 7342 - - 5 #12-24 0.216 0.398 430 537 672 7342 7342 7342 7342 7342 6 1/4-14 0.250 0.480 518 648 810 11262 11262 11262 - - 7,8 1/4-20 0.250 0.480 - 648 810 11262 11262 11262 11262 11262 11 5/,6-18 0.313 n/a2 - - - 11692 11692 - - - 12 5/76-24 0.313 n/a2 - - - 13262 13262 13262 13262 13262 DESIGN STRENGTH(LRFD) 1 #10-16 0.190 0.357 578 723 7812 7812 7812 - 7 - 2 #10-16 0.190 0.384 622 778 7812 7812 7812 - - - 3,4 #12-14 0.216 0.398 645 806 1007 11922 11922 11922 - - 5 #12-24 0.216 0.398 645 806 1007 11922 11922 11922 11922 11922 6 1/4-14 0.250 0.480 778 972 1215 1701 18302 18302 - - 7,8 1/4-20 0.250 0.480 - 972 1215 1701 18302 18302 18302 18302 11 5/16-18 0.313 n/a2 - - - 18712 18712 - - - 12 5/,6-24 0.313 n/a2 - - - 21212 21212 21212 21212 21212 For SI: 1 inch=25.4 mm, 1 lbf=4.4 N,1 ksi=6.89 Mpa. 'Available strengths are based on calculations in accordance with AISI S100,unless otherwise noted. 2Available strengths are based on laboratory tests,with safety factors/resistance factors calculated in accordance with AISI S100,or on the shear strength of the integral washer. Increasing values for higher steel tensile strength per Note 6 is not allowed. 3For tension connections,the lowest of the available pull-out,pull-over,and fastener tension strength must be used for design. 4Vauues are based on steel members with a minimum yield strength of F,,=33 ksi and a minimum tensile strength of F.=45 ksi. SAvailable capacity for other member thickness may be determined by interpolating within the table. 6For steel with a minimum tensile strength F„?58 ksi,multiply tabulated values by 1.29 and for steel with a minimum tensile strength F.?65 ksi steel,multiply tabulated values by 1.44. c3 I 4' ,•li.ESR-3332 I Most Widely Accepted and Trusted Page 5 of 6 TABLE 5—TENSILE PULL-OUT CAPACITY OF SCREW CONNECTIONS,pounds-forcel'2.3,4,5 SCREW SCREW NOMINAL DESIGN THICKNESS OF MEMBER NOT IN CONTACT WITH SCREW HEAD(in.) TYPE DESIGNATION DIAMETER (in.) 0.048 0.060 0.075 0.105 1/8" 'tie' ,I4., alts" ALLOWABLE STRENGTH(ASD) 1 #10-16 0.190 136 193 236 307 297 - - - 2 #10-16 0.190 136 193 236 307 297 - - - 3,4 #12-14 0.216 132 205 264 328 510 665 - - 6 1/4-14 0.250 131 207 255 342 561 899 - - 7,8,9,10 1/4-20 0.250 _ - 2046 2606 4236 524' 914' 1044 1206 11 5/16-18 0.313 - - - 520 707 - - - 12 5/16-24 0.313 - - 459 637 724 1189 1424 DESIGN STRENGTH(LRFD) 1 #10-16 0.190 217 309 378 492 476 - - - 2 #10-16 0.190 217 309 378 492 476 - - - 3,4 #12-14 0.216 211 328 423 525 816 1064 - - 6 1/4-14 0.250 210 331 409 548 897 1439 - - 7,8,9,10 1/4-20 0.250 - 3266 4166 6776 838' 1462' 1670 1930 11 5/16-18 0.313 - - - 832 1131 - - - 12 5/16-24 0.313 - - _ - 735 1019 1159 1903 2279 For SI: 1 inch=25.4 mm, 1 Ibf=4.4 N,1 ksi=6.89 Mpa. 'Available strengths are based on laboratory tests,with safety factors/resistance factors calculated in accordance with AISI S100. 2For tension connections,the lowest of the available pull-out,pull-over,and fastener tension strength must be used for design. 'Values are based on steel members with a minimum yield strength of Fy=33 ksi and a minimum tensile strength of F„=45 ksi. 4Available capacity for other member thickness may be determined by interpolating within the table. Sunless otherwise noted,for steel with a minimum tensile strength F„?.58 ksi,multiply tabulated values by 1.29 and for steel with a minimum tensile strength F„z 65 ksi steel,multiply tabulated values by 1.44. 'When both steel sheets have a minimum specified tensile strength of F„z 52 ksi(e.g.ASTM A653 SS Grade 37),multiply tabulated values by 1.15. 'When both steel sheets have a minimum specified tensile strength of F„z 58 ksi(e.g.ASTM A36),multiply tabulated values by 1.29. TABLE 6—MINIMUM FASTENER SPACING AND EDGE DISTANCE BASIC SCREW FASTENED MINIMUM SPACING MINIMUM EDGE MINIMUM EDGE DISTANCE FOR DIAMETER DISTANCE (inch) MATERIAL (3d) (1.5d) FRAMING MEMBERS(3d) 0.190 (#10) Steel 9/16" 5/16" 9/16' 0.216 (#12) Steel 11/15• 3/5, 11/15, 1/4 Steel 3/4u 3/8., 3/4" 5/16 Steel 15/150 1/2" 15/7800 For SI: 1 inch=25.4 mm. • • „1 1.,e, ESR-3332 I Most Widely Accepted and Trusted Page 6 of 6 -� Ina�1�0111 o 111111�ti O aI\ �1��t%�■�►- FIGURE 1-#10-16 PHILLIPS PAN HEAD FIGURE 7-1/4-20 INDENTED HEX WASHER HEAD TYPE 1 SCREW ROUND BODY TAPTITE TYPE 8 SCREW f`him -P „-,..;::_2c.,-.:1 1.4 a FIGURE 2-#10-16 INDENTED HEX WASHER HEAD FIGURE 8-5/16-18 INDENTED HEX WASHER HEAD TYPE 2 SCREW ROUND BODY TAPTITE TYPE 11 SCREW S I..11-1;1A-l W�i h'1+^ -`/ \ ! �./.' V j+�'Y?,...Nc •4., c.�,.r.✓. - (*44-I- ON 3-#12-14 INDENTED HEX WASHER HEAD FIGURE 9-5/16-24 INDENTED HEX WASHER HEAD TYPE 3 AND 4 SCREW WITH SHANK SLOT • TYPE 12 SCREW I IR ?.LAX MUh1 LOAD BERING •(g!-”=s ; jCl .,fir ,4 AF2CA FIGURE 4-#12-24 INDENTED HEX WASHER HEAD FIGURE 10-PHILLIPS PAN HEAD AND INDENTED TYPE 5 SCREW HEX WASHER HEAD LOAD BEARING AREA LO:,D EEARI@as Q, Ilia i Nl��l���OTC ARV, -14;7-4-: -- :. ' --- -. FIGURE 5-1/4-14 INDENTED HEX WASHER HEAD FIGURE 11-INDENTED HEX WASHER HEAD WITH TYPE 6 SCREW SHANK SLOT LOAD BEARING AREA LOADEEARI2'G * 11.41481m::› . 1 AREA e '. FIGURE 6-1/4-20 INDENTED HEX WASHER HEAD FIGURE 12-INDENTED HEX WASHER HEAD ROUND BODY TYPE 7 SCREW TAPTITE LOAD BEARING AREA SUBMITTAL /0 Job Title: MACEY'S STORE Elevation: (ft) 108 Date: 08/13/14 Submitted By: Ron Enkelis JOHNSON AIR PRODUCTS 2220 SE NINTH AVE PORTLAND , OR 97214-4661 US Phone: (503)234-5071 Fax: (503)233-0451 Email Address: renkelis @johnsonair.com • GREENHECK ® Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715) 359-6171 FAX (715) 355-2399 www.greenheck.com CAPS 4.15.1235 G:Wob Data Files\Ron\MACEY'S STORE.gfcj Page 1 of 11 // 0-- i,'� EENHE K Printed Date: 8/13/2014 .'��1''TiII iY it Job: MACEY'S STORE Building Value in Air. Mark: EXHAUST FANS 50 - Model: GB-300-15 r Belt Drive Centrifugal Roof Exhaust Fan -,,� . I I-1. 36 ci Dimensional Quantity 2 Weight w/o Acc's(lb) 142 i 1 8.25 –Weight w/Acc's(lb) 237 I / I 1 Max T Motor Frame Size 184 Optional Damper(in.) 30 x 30 40 1 1.75 Roof Opening(in.) 32.5 X 32.5 Reference assembly view drawings for actual dimensions with mounted accessories 'Overall height may be greater depending on motor 1.0 1.5 Performance =-,-._-?? ;:-: " -,,, s: r Requested Volume(CFM) 8,500 '. 1.,„,,,: .,,,,;,;;-.,:; I 1!546:i▪ .FRPM Actual Volume(CFM) 8,500 #, 1•'z I • External SP(in.wg) 0.1 i•Total SP(in.wg) 0.1 �,.: -:\ " Fan RPM 546 3) `:' `j•' - Operating Power(hp) 1.18 c ,;,''\f,▪,l`-„, -;,\': Elevation(ft) 108 m Airstream Temp.(F) 70 "- to a Air Density(ft3) 0.075 � - i.:: ; ,:• "`%r ��� y`° I _l._ _1._. Air 1.I Drive Loss ,, "` < Tip Speed(ft/min) 4,357 \%' • '`' c., � m Static Eff.(%) 12 0.2 = .. - --- — — — 0.3 o 't;,:;t.-,,.°mo I O° 0.0 .. 'g s te m I _.... ! _ :_.. . ! Motor Motor Mounted Yes 0 1 2 3 4 5 6 7 8 9 Size(hp) 1 1/2 Volume (CFM)x 1,000 V/C/P 460/60/3 L Operating Bhp point Enclosure ODP 0 Operating point at Total SP Motor RPM 1725 o Operating point at External SP Fan curve Windings 1 - - -.-System curve NEC FLA*(Amps) 3 Brake horsepower curve amca WORLDWIDE Sound Power by Octave Band Notes: CERTIFIED Y All dimensions shown are in units of in. Sound *FLA-based on tables 150 or 148 of National Electrical SOUAD Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones Code 2002.Actual motor FLA may vary,for sizing thermal AIR overload,consult factory. D. Prmoamoncc Inlet 81 86 77 69 66 63 55 50 75 63 13.8 LwA-A weighted sound power level,based on ANSI S1.4 +- - dBA-A weighted sound pressure level,based on 11.5 dB monmat�0d attenuation per Octave band at 5 ft-dBA levels are not anpeomnoi '44,s,Vie, licensed by AMCA International iatmaanonnime:*D. Sones-calculated using AMCA 301 at 5 f1 CAPS 4.15.1235 G:Wob Data Files\Ron\MACEY'S STORE.gfcj Page 2 0111 /2 Printed Date: 8/13/2014 E.GREENHECK Job: MACEY'S STORE Building Value in Air. Mark: EXHAUST FANS Model: GB-300-15 Belt Drive Centrifugal Roof Exhaust Fan Standard Construction Features: -Aluminum housing-Backward inclined aluminum wheel-Curb cap with prepunched mounting holes-Motor and drives isolated on shock mounts- Birdscreen-Ball bearing motors-Adjustable motor pulley-Adjustable motor plate-Fan shaft mounted in ball bearing pillow blocks-Bearings meet or exceed temperature rating of fan-Static resistant belts-Corrosion resistant fasteners- Sizes 141 and larger have internal Lifting lugs Options &Accessories: NEMA Premium Efficient Motor-meets NEMA Table 12-12 UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Ship With Unit,Field Mounted Roof Curb-Galv.,GPI-40-G12,Under Sized 1.5 in.Total Damper,VCD-23-PB-30X30(Loose),Not Coated Damper Actuator(MS8104F1010),24 VAC Actuated Bearings with Grease Fittings,L10 life of 100,000 hrs(L50 avg.life 500,000 hrs) Unit Warranty:1 Yr(Standard) CAPS 4.15.1235 G:Wob Data Files\Ron\MACEY'S STORE.gfcj Page 3 of 11 '? GREElrHEdrI' Jrob: MACEY'S STORE Building Value in Air. Mark: EXHAUST FANS Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with.enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1 1/2 hp Voltage: 460 UL Listed: Yes Manufacturer: Square D Cycle: 60 Amperage: . 30 CSA Approved: Yes Overload Protection: None Phase: 3 Switch Pole(s): 3 Rating: 10 hp Mounting: Ship With Unit RPM: 1725 Wiring (Exp. Resist.): None Electrical Drawing Details ?Th C Wiring Schematic 3.00 8 4.25 0 • • • 0.56 —0.41 2.75 • • • 1.63— 2.88 - 2.44 - [6171■ Notes:All dimensions shown are in units of in. CAPS 4.15.1235 G:Wob Data Files\Ron\MACEY'S STORE.gfcj Page 4 of 11 AIM Printed Date: 8/13/2014 OGR��NECK Job: MACEY'S STORE Building Value in Air. Mark: EXHAUST FANS Assembly Drawing Type: Belt Drive Centrifugal Roof Exhaust Fan 01 30.0 32.5 Exhaust Damper&Ductwork SQ SQ Suggested Roof Opening �\ Al��•/ 1111 TOP VIEW 50.0 36.0 48.0 8.3 L J 40.0 1 1.8i 12.0 Flat Roof Curb 1 FRONT VIEW Notes:All dimensions shown are in units of in.. CAPS 4.15.1235 G:\Job Data Files\Ron\MACEY'S STORE.gfcj Page 5 of 11 17 0 Ufl EE Y IUIEL,1C Printed Date: 8/13/2014 II Job: MACEY'S STORE Budding Value in Air. Mark: EXHAUST FANS Control Damper Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications-Galvanized 16 ga channel frame- Galvanized blades with reinforcements- Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in.dia.-Synthetic axle bearings-Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: Actuator Type: 24 VAC End Switch: No Actuator Configuration: Manufacturer: Honeywell Jackshaft Quantity: 0 Model: MS8104F1010 Mounting: Internal Quantity: 1 1 .3 max. 1 .3 max. 000 I� ! � I JI II II � 30 � . 30 5.0 10.0 Min. DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize CAPS 4.15.1235 G:\Job Data Files\Ron\MACEY'S STORE.gfcj Page 6 of 11 /(‘ +.^ GREEN HECK Printed Date: 8/13/2014 Pi I11 6r fl Job: MACEY'S STORE Building Value in Air. Mark: EXHAUST FANS Roof Curb Model: GPI Material: Galvanized Standard Construction Features: -Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum -Straight Sided without a cant- 2 in. mounting flange-3 lb density insulation - Height -Available from 8 in.to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the "Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may NOT be the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. -Security bars are optional and must be specified. Frames and gridwork are all 10 ga steel. Gridwork is welded to the frame and the frame is°welded to the curb. To prevent corrosion, they are coated with Greenheck's high performance Permatector coating. 38.5 38.5 j_ ti 12.0 42.5 42.5 ISOMETRIC VIEW Notes:All dimensions shown are in units of in. CAPS 4.15.1235 G:Wob Data Files\Ron\MACEY'S STORE.gfcj Page 7 of 11 / / / 'UflEEi1VfEI K Printed Date: 8/13/2014 GREEN HECK Job: MACEY'S STORE Building Value in Air. Mark: EXHAUST FANS GB-300-15 Min/Max Fan Curve Performance Requested Actual External Total Operating Volume Volume SP SP Fan Power (CFM) (CFM) (in.wg) (in.wg) RPM (hp) 8,500 8,500 0.1 0.1 546 1.18 - 2.4 ,;v , ,.. 6 :, :cc\: i'?.;: 8 — : K: x:.. • • .F:, �:_ ?,-: o 2 a3 a:-----,---,,,,,:::•:: W:. r.�.U .... }� -.::<Z?:-:4;p0:.::. :.:: .1 : ^ • CO 0.4 --= =y;;::_ :;N __ _ --- -- ,i•_29.9tF'� d _. _ ,•:::::::::--,/ :::::::::, . • @ Mir1 FRPM (4 _.._ _ I — i : 0.0 �.._ - .T.._.._..T.._.._.•I.. 0 • • •0 3 6 9 12 15 • Volume (CFM) x 1 ,000 A Operating Bhp point O Operating point at Total SP o Operating point at External SP Fan curve --.-..-'.-System curve Brake horsepower curve CAPS 4.15.1235 G:\Job Data Files\Ron\MACEY'S STORE.gfcj Page 8 of 11 GREEAIHECK Printed Date: 8/13/2014 Job: MACEY'S STORE Building Value in Air. Mark: EXHAUST FANS AMCA CIMCC WORLDWIDE CERTIFIED RRTIIIGS SOURD MID AIR PERrORAIAACE AIR % MOVEMEAT flt11)COATROI" •�% nssoc1t1T1O0 '4 IRTERAflT1O11flL.111C.° AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW) includes transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) includes transmission losses. Performance ratings include the effects of birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A:free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only CAPS 4.15.1235 G:Wob Data Files\Ron\MACEY'S STORE.gfcj Page 9 of 11 /y Printed Date: 8/13/2014 '' It' GREENHECK Job: MACEY'S STORE Building Value in Air. Mark: INTAKE HOODS FGI Hooded Gravity Intake A B --1 STANDARD CONSTRUCTION FEATURES •Precision formed locked rib construction. •Available in aluminum or galvanized steel construction. •0.5 in.galvanized steel mesh birdscreens. • Heavy gauge galvanized steel support members.•Hood can be removed c----- c completely from the base or hinged open. •Units with a throat size exceeding 60 in.x 120 in.will have 12 in.galvanized I Base Height bases as standard. I I 1.±5 } •Recommended roof opening dimension is at least 2.5 in.larger than the damper size. �-- TW TL h—f Curb Cap Width Curb Cap Length SELECTED OPTIONS&ACCESSORIES • Galvanized Birdscreen-0.5 in.Mesh Type Galvanized Steel Housing Curb GPI-G12 NOTE:All dimensions shown are in units of inches Damper VCD-23-PB,Chnl.Frm.,24 VAC,Int Mnt.,Dmpr Shipped Sep. DIMENSIONS . "TW" "TL" Curb Curb Opt. Opt. Base ID# Tag Qty Throat idth Length A(tn.) B(in.) C(in.) Width Length Width Length Damper wt.(Ib) H(in)t Assembled t (in.) (in.) (in.) (in.) (in.) (in.) 1-1 2 40 40 67 72 23 46 46 40 40 172 5 Yes PERFORMANCE Volume Throat Throat ID# Tag Qty (CFM) SP(in.wg) Area(ft2) Velocity (ft/min) 1-1 2 0 0 11.11 0 CAPS 4.15.1235 G:Wob Data Files\Ron\MACEY'S STORE.gfcj Page 10 of 11 ao 'FI- GREENHECK Jrob: MACEY'S STORE Building Value in Air. G P 1 Roof Curb STANDARD CONSTRUCTION FEATURES Actual L Actual W •Welded Aluminum (0.064 in.)or galvanized (18 ga)construction • Straight sided •2 in. roof mounting flange •3#density insulation •Wood nailer. 1.75 Roof Opening-The Maximum roof opening dimension should not be greater than the"Actual"top outside dimension minus 2 in.. With dampers, e'ght the Minimum roof opening dimension should be at least 2.5 in. more than the damper dimension. <,,, , . '4.. NOTES: "The Roof Opening Dimension may NOT be the Structural Opening Dimension. Fl1%4 Han e L *Maximum single piece shipping length is 76". �^� are 10 Bass are optional and must bt the frame and the and a iswork are all 10 ga steel. Grillwork is welded to the frame and the frame is welded to the curb. To prevent corrosion,they are coated with Greenheck's high performance Permatector coating. NOTES:All dimensions shown are in units of inches Cap Actual Flange Height Damper Tray Mark WxL WxL WxL WxL INTAKE HOODS-1 2 46 x 46 44.5 x 44.5 48.5 x 48.5 12 CAPS 4.15.1235 G:\Job Data Files\Ron\MACEY'S STORE.gfcj Page 11 of 11