Loading...
Permit III CITY OF TIGARD MASTER PERMIT i 11 a. COMMUNITY DEVELOPMENT Permit#: MST2014-00176 T[GA R D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/20/2014 Parcel: 2S112CB17100 Jurisdiction: Tigard Site address: 15111 SW 83RD AVE Subdivision: HAMPTON COURT Lot: 20 Project: Nag Project Description: Installation of solar photovoltaic system BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right 0 Detectors: Total: 0 sf Value: $7,280.00 Rear 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker 0 Hose Bib: 0 Backwater Value: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: NAG,SAUMYA SUNRUN INSTALLATION SERVICES INC Required Items and Reports(Conditions) 15111 SW 83RD AVE 3380 SE 20TH AVE TIGARD,OR 97224 PORTLAND,OR 97202 PHONE: 503-352-9859 PHONE: 503-501-6377 FAX: Total Fees: $319.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow t e rules aby the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy• •e rules or dire t questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: A`— __ Permittee Signature: —Li _______\ C. •'.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Applicatio_4ECE$VEE Residential FOR OFFICE USE ONLY OCT 14 20',4 Received p �� City of Tigard DateB : Q Permit No..Ar / - � pr 13125 SW Hall Blvd.,Tigard,OR 99�fu„ tt_AV'1 Plan Review In, Phone: 503.718.2439 Fax: 503.5 1V�1 t�Ar11 R! Date/By: �W •' t� l '. •her Permit: TIGARD Inspection Line: 503.639.4175 ViUILDth`,1 enRI1 P Date Ready/By: lurk: El See Page 2 for Internet: www.tigard-or.gov Notified/Method: //)//6 /K1, Supplemental Information 4 rr,nfa t) ,d TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all `Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ❑Commercial/industrial Valuation: S $ YO ❑Accessory building ❑Multi-family Number of bedrooms: ❑ Master builder Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 1Sill 5 W W3 f Z 4e)E New dwelling area: square feet City/State/ZIP:1-1 504.1 . ( ) (\"11 Li Garage/carport area: square feet Suite/bldg./apt.no.: Project name: 601 R l 1 t,J4.( Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. 1� Valuation: S IA '',A, k12(ov\ 64- � 1 .6L1 W sdo,r- (A.., v-0l ,,c g skt,,. Existing building area: square feet New building area: square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: Name: SkUv." Type of construction: Address: ,N� cx_S cijki, Occupancy groups: City/State/ZIP: t' Existing: Phone:(50)) 3b1_kW S 9 Fax:( ) New: ❑ APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: ¶ &A NANA I �t L \d\I\ 5.etU',\.e 5 Iv( Structural plan review fee(or deposit): Contact name: .),AA.h T-e \e r FLS plan review fee(if applicable): Address: 31%Q S : ),() A-v E Total fees due upon application: p City/State/ZIP: W f 4v t n R i7 101 Amount received: Phone:( tool) D WO` l suk Q Fax::( ) E-mail: \ PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* �.vo. .. �t551e(' @ suvauv. w.t.Caws Commercial and residential prescriptive installation of CONTRACTOR C �} roof-top mounted PhotoVoltaic Solar Panel System. Business name: StaN r I.I.0 I 5L"urt,�n 5Ytdt\Ces -t-1..C. Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: N„,{ e_k_5 ,-11,a,.( / Solar Installation Specialty Code checklist. City/State/ZIP: rl Permit Fee(includes plan review $180.00 and administrative fees): Phone:( ) 4 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: `(CO 4(4 Total fee due upon application: $201.60 Authorized signature: v1/4.-',______ This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete.r � ! +' *Fee methodology set by Tri-County Building Industry Print name: C1Ra� F.CSSVer Date: 101 14/ 1I Service Board. I:1Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY City of Tigard Elli DaeBy 10 ( /1( �4 i PermitNo.: 6 apt , i 125 SW Hall Blvd.,Tigard, 9CJF() Plan Review Phone: 503.718.2439 Fax: 5 . 960 Date/By: Other Permit: TIGARD Inspection Line: 503.639.4175 OCT 1 4 21,4 Date Ready/By: Juris 65 See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information �p + TYPE OIC�t WORK PLAN REVIEW ���`'' Please check all that apply(submit 2 sets of plans wiitems checked below): ❑New construction �Additioridrt3plAC @mint ❑Service or feeder 400 amps or more 0 Building over three stories. ❑ Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. less to ground,or exceeds 14,000 ❑Commercial-use agricultural ❑ I-and 2-family dwelling ❑Commercial/industrial ❑Accessory building amps for all other installations. buildings. ❑Multi-family ❑ Master builder Other: ❑Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived system. ❑Addition of new motor load of ❑"A'."E", 'l-2","l-3", Job no.: Job site address: 15,i( >� 1 0_ AV F IOOor more residential occupancy. ❑Six or more residential units. ❑Recreational vehicle parks. City/State/ZIP: �v 1-\ 4 \U ❑Health-care facilities. ❑Supply voltage for more than 1 AfAI G t 1���1 1 ❑Hazardous locations. 600 volts nominal. Suite/bldg./apt.no.: J Project name: 6x--)t R_Il I,v A.C ❑Service or feeder 600 amps or more FEE SCHEDULE Cross street/directions to job site: Description I Qty. I Fee. I Total I • New residential single-or multi-family dwelling unit. Includes attached garage. 1,000 sq.ft.or less f 168.54 4 Subdivision: Lot no.: . Ea.add'(500 sq.ft.or portion 33.92 I Tax map/parcel no.: Limited energy,residential 75.00 2 DESCRIPTION OF WORK (with above sq.ft.) . ) Limited energy,multi-family 75.00 2 tv s faCt\"i'G� o f .C \W, 5Jtctr Q�d a vd1 -, ( residential(with above sq.ft.) Renewable Energy _ ❑ See Page 2 5 \A„.... Services or feeders installation,alteration,and/or relocation ❑ PROPERTY OWNER ❑ TENANT 200 amps or less 100.70 2 f 201 amps to 400 amps 133.56 2 ^V Name: , S Cukvs. CA 401 amps to 600 amps 200.34 2 Address: ' S ri` 5 W ((I,.,, 4 l 601 amps to 1,000 amps 301.04 2 Over 1,000 amps or volts 552.26 2 •City/State/ZIP: t%y., r 0 t ��Z�4 Temporary services or feeders installation,alteration,and/or Phone:(S 0))3 C-A —t)if 59 Fax:( ) relocation 200 amps or less 59.36 1 Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.54 2 Owner signature: Date: Branch circuits—new,alteration,or extension,per panel _ ❑ APPLICANT ❑ CONTACT PERSON A.Fee for branch circuits with -- above service or feeder fee, Business name: T ` each branch circuit 7.42 2 v B.Fee for branch circuits without Contact name: tktGA/„ 'es \.e r service or feeder fee,first 56.18 2 branch circuit Address: )WO ¶t, .10) /(At E. Each add'(branch circuit 7.42 2 City/State/ZIP: ¢ 1 1 ` Ql Miscellaneous(service or feeder not included) to r 3k,,,„, 0 R I /)dA Each manufactured or modular 67.84 2 Phone:(C _ 4 Dr o Yo t-1 1 t Q Fax: ( ) dwelling service and/or feeder )7 D Reconnect only 67.84 2 E-mail: {Vt,n 4 t"CSSke f'®S�...ruv.l, . ..t. (oVM Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name: /` �� Signal circuit(s)or limited-energy See ' JLA A Tkv. S a t v`^ )Y � ,e -L.'- C panel,alteration,or extension. _ Page 2 2 Address: 0.' ��� Each additional inspection over allowable in any of the above City/State/ZIP: t/ Additional inspection(1 hr min) 66.25/hr Investigation(I hr min) 66.25/hr Phone:( ) If Fax:( ) Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.:No 4 by Electrical Lic.: (,l4 9), Suprv.Lic.:53-45/�$ specifically listed(%z hr min) ELECTRICAL. PERMIT FEES Suprv.Electrician signature,required: /��- Subtotal: Print name: ��4" 70p t, s"pys/ !�Date:AO l y?f f Plan review(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: G _ TOTAL PERMIT FEE: 1���y This permit application expires if a permit is not obtained within ISO Print name: �� � C��`C�` Date: �v/♦l) days after it has been accepted as complete. • Number of inspections allowed per permit. 1:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 05/21/2013 440-4615T(I1/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined ... $75.00 Description Qty. I Fee I Total I ' Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 I-1 Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 ❑ Burglar Alarm Wind generation systems in excess of 25 kva: 25.01 to 50 kva 301.04 2 ❑ Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance with 552.26 2 OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning System* Solar generation systems in excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—noadditional charge 0.0 3 ElOther: additional inspection over allowable in any of the above: Other: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed('/hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fee): State surcharge(12%of permit fee): Check Type of Work Involved: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 ❑ Audio and Stereo Systems days after it has been accepted as complete. * Number of inspections allowed per permit. ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I'.\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 05/21/2013 City of Tigard '' Building Division • - 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: IS 111 ilA f t 4\(Z City: 1' y b ej A Zip: Owner's Name: /V r. Date: 1,0 /pi l/ � Contractor's Name: CCB #: L 6 tAkt .s . , r . eep Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation 111 Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? IN, No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ISZ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes",qualifies for El Yes the prescriptive path. above No I:Building/Forms/PhotoVoltaic-Checklist.docx Is the construction material wood and does "`C Yes Type of If"Yes", qualifies for the construction qualify Construction as"conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. lq Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3)of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. of composition shingle. Is the roof mounted Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? Y I:Building/Forms/PhotoVoltaic-Checklist.docx • ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel is less than 18 inches, panels? 18 inches or less qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? N /� Size and spacing of If"Yes",qualifies for /trt' fastener? El Yes the prescriptive path. ❑ No Is the roof decking of WSP min. ''Y2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 1:Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: RF C. �1 f Model Number: f E C `(Dpi E ( M,k Listing Agency: l�l L 4 I:/Building/Forms/PhotoVoltaic-Checklist.docx PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-SCALE: NTS MODULE NOTES: TABLE OF CONTENTS 1. 3640W DC, 3000W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK) DIMENSIONS: 2. (14) REC SOLAR: REC260PE(BLK) MODULES WITH (1) ARRAY PITCH MAGNETIC TRUE 65.55"x 39.02"x 1.5" PAGE DESCRIPTION POWER-ONE: PVI-3.0-OUTD-S-US-A(240V) INVERTER. ORIENTATION ORIENTATION `a1d st 2. PORTRAIT: CLAMP 8.2"-16.4"FROM EDGE # 3. TWO STORY COMP SHINGLE ROOF AT 30°PITCH. 3. LANDSCAPE: CLAMP 0"-9.8" FROM EDGE 4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT AR-01 30° 254° 270° SW Bonita PV-01 SITE PLAN &MECHANICAL RUN PLACEMENT WITH CUSTOMER. M1•r;,irr ���$ RACKING NOTES: 5. ROOF STRUCTURE: 2X4 PRE FABRICATED TRUSSES wsatne,st 15111 SW 83rd Ave 1. SNAPNRACK SERIES 100 OR S100 UL LISTED; • 24"OC. FLUSH MOUNT L-FOOT. SEE PEN DO1. PV-02 ELECTRICAL 2. 4'-0"MAX RAIL SPAN 6. APN#: B17100 7. CONTACT:CT: SA UMYA NAG, (503)352 9859 ra SW Durham a 3. 1'-4"MAX RAIL END OVERHANG SA 8. DESIGN CRITERIA: 4. RAFTER AND PENETRATION LOCATIONS TO BE 8.1. SYSTEM WEIGHT: 3LBS/SQFT. • DETERMINED IN THE FIELD OCT 1 4 2 ':4 8.2. EFFECTIVE WIND SPEED: 95 MPH 3-SEC GUST. . . 5. LAG SCREWS: 5/16"X 3.5":2.5"MIN EMBEDMENT 1 8.3. SNOW LOAD : 25LBS Bridgeport Village Mall • r ,b CITYOF ilmiu ' = Du BMW NIflgin► �isr�m 'r Tualatin Country Club AF `-' " E SITE PLAN -SCALE=3/64"= 1'0" 4v D1 -AR-01 -SCALE: 118"=1'-0" - •r NOTE:- � • INDICATES TSRF VALUE AT MARKED LOCATION FIRE SETBACKS (3'TYP) ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24 INCHES ON CENTER ❑ ❑ ❑ ❑ ❑ (E) PROPERTY LINE IN ANY DIRECTION WHERE ARRAY IS (E) DRIVEWAY LOCATED WITHIN 4 FEET OF A ROOF A� Q Ita (E) RESIDENCE EDGE,HIP,EAVE OR I4IDOS. 84% OSISC 305.4..3(B) a i ig . \ PL PL PL it a j a a W Q Iii I. y CITY OF TIGARD a ,- ce REVIEWED FOR CODE COMPLIANCE < e M co D2 -ELEVATION -SCALE: 3/32"= 1'-0" Approved: 1 ai a d . � , OTC: [ ] ��/ - 'omit#: IA,t,STZO( Ci (`7� PL PL PL \ (N)ARRAY AR-01 j . . \- 6" •- I "`e' 1,t((4� ��1�14V-- ' FIRE SETBACKS (E) MAIN PANEL .�'/ Suite - (3'TYP) (INTERIOR WALL) By: "''T► Date: `O t(AA- (N) INVERTER WITH INTEGRATED DC DISCONNECT i (INTERIOR WALL) 25' 24'-2" (N) PV PRODUCTION METER - 18-7" OFFICE COPY ' AND AC DISCONNECT (EXTERIOR WALL) (E) SERVICE ENTRANCE (EXTERIOR WALL) • " 'S --- SUNRUN,INC. 3380SE20TH,PORTLAND,OR97202 M. REGALADO SUNRUN PROJECT NUMBER: NAG RESIDENCE SITE PLAN& REV:A sunrun OR CL#180464 PHONE 503-785-4332 DESIGNER: FAX 503205-0748 PV-01 9499454483.000001 DRAFTER: DI NAG (601 R-111 NAG) 15111 SW 83RD AVE, TIGARD, OR 97224 MECHANICAL 10/13/2014 LINE DIAGRAM: 120/240 VAC SINGLE PHASE SERVICE GI METER PGE 24311 1219 UTILITY ' GRID Ci EXISTING 200A MAIN p BREAKER I EXISTING < 200A MAIN LOCKABLE POWER-ONE: FACILITY PANEL BLADE TYPE DEDICATED PV PVI-3.0-OUTD-S-US-A (240V) LOADS AC DISCONNECT KWH METER 3000 WATT INVERTER JUNCTION BOX PV MODULES 3 3 3 -2 OR EQUIVALENT 1 �� —��O / REC SOLAR: REC260PE(BLK) —0 p— °moo 0 0 `� _ *,j// (14) MODULES 0 4>�° `tt'' (1) STRING OF (14) MODULES — FACILITY — - . 20A PV GROUND SQUARE D 250V METER SOCKET DUAL MPPT TRACKERS STRING BREAKER AT DU221RB 125A CONTINUOUS COMBINER & LOAD RATED DC OPPOSITE END 3R, 30A DISCONNECT AND AFC! OF BUSBAR 120/240VAC 1. NOTES TO INSTALLER: SIGNAGE: WARNING 2. 265 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. CONDUIT SCHEDULE WARNING-Dual Power Sources ELECTRIC SHOCK HAZARD 3. IN MAIN PANEL REPLACE (2) 15A 2P BREAKERS WITH NEW 15/20/15A it Second source is photovoltaic system CONDUIT CONDUCTOR NEUTRAL GROUND DO NOT TOUCH TERMINALS 1-2-1P QUAD BREAKER. CONNECT PV SYSTEM TO 20A 2P PORTION OF LABEL PLACEMENT MAIN PANEL TERMINALS ON BOTH LINE AND NEAR METER LOAD SIDES PE BE ENERGIZED NEW QUAD. 1 NONE (2) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER N THE OPEN POSITION WARNING 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 NONE (1)6 AWG THHN/THWN-2 ,,c,.,,„.'�,„,„`„,,,,,� DC VOLTAGE IS ALWAYS PRESENT _ LABEL PLACEMENT:AC DISCONNECT. WHEN SOLAR MODULES 3 3/4” EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 I (1) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 COMBINER BOX,INVERTER ARE EXPOSED TO SUNLIGHT _ WARNING-Elactrlc shock HazardJ LABEL PLACEMENT: y No user sarvicpablo parts inside / DC DISCONNECTS [onlacl autbonZOO snrvvnr fur assistance LABEL PLACEMENT:AC DISCONNECT. WARNING COMBINER BOX,INVERTER CAUTION:SOLAR ELECTRIC ELECTRIC SHOCK HAZARD ELECTRICAL NOTES: SYSTEM CONNECTED IF A GROUND FAULT IS INDICATED LABEL PLACEMENT: NORMALLY GROUNDED CONDUCTORS 1. PHOTOVOLTAIC SYSTEM WILL CONDUIT,JUNCTION BOXES MAY BE UNGROUNDED AND ENERGIZED COMPLY WITH 2011 NEC. • PHOTOVOLTAIC POWER LABEL PLACEMENT 2. ELECTRICAL SYSTEM GROUNDING SOURCE INVERTER WILL COMPLY WITH 2011 NEC. LABEL PLACEMENT: • 3. PHOTOVOLTAIC SYSTEM IS CONDUIT,JUNCTION BOXES WARNING UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS LABEL PLACEMENT: TERMINALS ON BOTH LINE AND INVERTER. SYSTEM COMPLIES ALL DISCONNECTS LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WITH 690.35. MODULE CHARACTERISTICS SYSTEM CHARACTERISTICS -INVERTER 1 LABEL PLACEMENT: 4. MODULES CONFORM TO AND ARE AC DISCONNECTS LISTED UNDER UL 1703. REC SOLAR: REC260PE(BLK) 260 W SYSTEM SIZE 3640 W 5. INVERTER CONFORMS TO AND IS OPEN CIRCUIT VOLTAGE 37.8 V SYSTEM OPEN CIRCUIT VOLTAGE 288 V WARNING LISTED UNDER UL 1741. 6. ARRAY DC CONDUCTORS ARE OPEN CIRCUIT VOLTAGE: (690.7) 41.1 V SYSTEM OPERATING VOLTAGE 214.9 V ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS SIZED FOR DERATED CURRENT. MAX POWER VOLTAGE 30.7 V MAX ALLOWABLE DC VOLTAGE 600 V UNGROUONDDED AND MAY BTE ENERGIZED 9.01 AMPS MODULE SHORT CIRCUIT CURRENT. SHORT CIRCUIT CURRENT 9.01 A SYSTEM OPERATING CURRENT 17 A LABEL PLACEMENT: 14.07 AMPS DERATED SHORT JUNCTION BOXES.COMBINER BOXES. SHORT CIRCUIT CURRENT (690.8(A)(1)) 11.26 A SYSTEM SHORT CIRCUIT CURRENT 22.53 A DISCONNECTS CIRCUIT CIRCUIT(690.8 (a)&690.8 _ (b)) LABEL PLACEMENT:AC BREAKER (INSIDE OR FRONT OF PANEL) SUNRUN, INC. 3380 SE 20TH.PORTLAND.OR 97202 DESIGNER: REV: A sunrun ORCL#180464 PHONE 503-766-4332 M. REGALADO SUNRUN PROJECT NUMBER: NAG RESIDENCE ELECTRICAL PV 02 FAX 503-205-0748 NAG (601 R-111 NAG) 15111 SW 83RD AVE, TIGARD, OR 97224 10/13/2014 9499454463 000001 DRAFTER: DI NOTES: REVISION: 4 - 5/16" LAG BOLTS MUST EMBED . 2.5" INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT - TORQUE ALL 5/16" HARDWARE TO ON TOP OF FLASHING SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT • COMPOSITION L FOOT - SILVER S.S. 10-16 FT-LBS CAN BE MOUNTED IN SS FLANGE NUT - BLACK S.S. 7-9 FT-LBS STEP 2: SLIP FLASHING OVER ANY ORIENTATION S.S. - RAILS CAN MOUNT TO EITHER SIDE L FOOT BASE AND UNDER ROW 35 X 1" (OR 1.25") OF L FOOT (UPSLOPE VS DOWNSLOPE) OF SHINGLES ABOVE SNAPNRACK S.S. BOLT AND k CHANNEL NUT SPLIT WASHER / -------10:-. ------------ ■W '%• " S.S. LAG SCREW 4� \ � /�' WITH FLAT WASHER SNAPNRACK W� 2.5" MINIMUM EMBEDMENT STANDARD RAIL IS STANDARD SNAPNRACK COMPOSITION s■ ROOF FLASHING STEP 1: BOLT L FOOT BASE TO ROOF WITH . LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. C 400:::: Id. I. ROOF DECKING TYP. loFLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3" USING UP TO TWO LEVELING SPACERS AS SHOWN IN "SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION • RAFTER TYP. S/�/� I/ �] /��/J MAINSTREAM ENERGY CORP. DESIGNER: G McPheeters - SCALE: DNS PART NUMBER: DESCRIPTION: REV (( 11/( \ N // ck 775FIER°`A"E,SUITE 200'-SA"`UIS OBISPO,CA 9740' USA D R an _ _ PEN DETAIL 01 , FLASHED L FOOT TO lul lU1\\`"J,lulllL''/ V rack- W PHONE(805528-9705••FA%(805528-9701 DRAFTER: Ryan S100 PEN D01 RAFTER PW t]ounid � m ` ts,,A�E>R .- . DATE: 120113 �,»,nAE..E�w�.��, R.,,o„ APPROVED BY: ii Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 15111 SW 83RD AVE, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final PASS MST2014-00176 Chip Barnett Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 15111 SW 83RD AVE, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection PASS - No C of O MST2014-00176 Chip Barnett Violation Summary: Inspector Contractor