Loading...
Permit II CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT "! s COMMUNITY DEVELOPMENT Permit#: FPS2014-00170 TFGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/20/2014 Parcel: 25101 DC04000 Jurisdiction: Tigard Site address: 7500 SW TECH CENTER DR 110 Project: Lennox Industries Subdivision: TECH CENTER BUSINESS PARK Lot: A Project Description: Relocate(3)fire sprinkler heads Contractor: JR MERIT INC Owner: WALTON CWOR SOUTHWEST 12 LLC 4504 NE 68TH DRIVE BY EQUITY OFFICE MANAGEMENT LLC VANCOUVER,WA 98661 PO BOX A-3879 CHICAGO, IL 60690 PHONE: 360-693-7474 PHONE: FAX: FEES Description Date Amount Specifics: Permit Fee-COM 10/20/2014 $91.44 12%State Surcharge-Building 10/20/2014 $10.97 Type of Use: COM Plan Review-Fire Life Safety-COM 10/20/2014 $36.58 Class of Work: ALT Type of Const: Occupancy Grp: Height: ft Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $138.99 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $2,000.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuan - • i wor uspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon UM' ' Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules • direct questions to OUNC b c. : 50 . 3 .1987 or 1.800.332.2344. Issued By: /Jig el 7 Permittee Signature: ��� Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. RECEIVED City of Tigard Permit No.: 4 P5 k/ ot�/1 D 13125 SW Hall Blvd.,Tigard,OR 9722 ('T [ 41• Phone: 503.718.2439 Fax: 503.598.10' I 2 0 2014 Date Received: - 7/7 p� Inspection Line: 503.639.4175 Internet: www.tigard-or.gov CITY OFTIGARD By: FIRE SP1���IKLE (DJt wAVIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: LE .i ',c Occupancy: L14HT HAI- 1) Job Address: 15b0 5 L) C-rc- 1714 Type of Construction: Suite: Contractor: S.v_ m tT Phone: 3 1093 '7 4?4 Number of Proposed or Altered Heads: `j Type:RS-A ft-E. Fl Hazard: I A i r• Density: 6.1 O I, Jtit r e _ -r Oregon Construction Contractors Board No. 1 Z. -7 3$ certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits,beams,partitions,walls,etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop(exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads(see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this document with a copy of the sketch attached shall be available for all inspections. Signature: --i_.—, Date: 10 -2 0- 1 Print Name: ,SASt" SAtnQc I:\Buil ding\Forms\FireSprinklerAftidavit 071514.docx Page 1 of 1 Building Permit ApplicatioI ECE1 TET Fire Protection System �vl l� FOR OFFICE USE ONLY • City of Tigard RecLI .l c/ Permit No /-16,01.e.,4 —c%u t - `, g OCT 2 0 2014 Date/By: /�J/d-t"f/ 1 r 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review f / n Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Penn":6a z964/41'e-e.2- 0 TIGARD Inspection Line: 503.639.4175 CITY OF TIGARD Date Ready/By: Juris IR See Page 2 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Addition/alteration/replacement El Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling , m Comercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: El Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 7 SZa t, 54.,) t,N 6111. 7 New dwelling area: square feet City/State/ZIP: /p2-17 p'O_ 1722'3 Garage/carport area: square feet Suite/bldg./apt.no.: 11() Project name:L C'KIN b?„, Covered porch area square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: $ 'Zoo RCLoL Pok-e SPa, t✓_t�67L Existing building area square feet New building area: square feet .PROPERTY OWNER ❑ TENANT Number of stories: Name:/43 -Tbp 0 Conk Smut rt cm) Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax:( ) New: 21 APPLICANT ❑ CONTACT PERSON NOTICE Business name: W.eit,,-r All contractors and subcontractors are required to be Contact name:�(���IJ{.Sf}MP��nI licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:4 5-4 S ki g (=,$.1-11 109,vC jurisdiction in which work is being performed.If the City/State/ZIP:V A-A,1 Lodjs.j L ) W¢j 9 G / applicant is exempt from licensing,the following reasons apply: Phone:(364)c.9-3 '?9 7 4 Fax: :( ) E-mail:JAStw! . SAM p co-(S 114612-rr .C Oy✓1 COON--TRACTOR BUILDING PERMIT FEES* Business name: .. lMl �t (Please refer to fee schedule) clo Permit fee: cf1.v4i Address: State surcharge(12%of permit fee): /J.`'7 City/State/ZIP: FLS plan review(40%of permit fee): 34* Phone:( ) Fax:( ) (Due upon application submittal.) -`°• CCB lic.: 12, 3 3 Total permit fees: Authorized signatur Amount received: /3g- 9 This permit application expires if a permit is not obtained Print name:-.-JASo•J SAn•f'coba Date: lo- 2 0- I within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board. I:1Building\Permits\FPS-PermitApp_071514.doe 440.46131(1 I/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) Type of Work: 2.) .\ddition/alteration only to sprinkler heads: 3.) Addition/alteration only to alarm devices: ❑ New system Number of sprinkler heads: Number of alarm devices: ❑ Addition or ❑ 1-10 heads: Affidavit required and ❑ 1-5 devices: Affidavit required and Alteration (3)copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system ❑ 11+heads: Plan review required and ❑ 6+ devices: Plan review required and (3) sets of plans. (3) sets of plans. Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler ❑ Wet ❑ Dry Additional Standpipes Information: Hazard Group Density Design Area K. Factor Sprinkler Project Valuation: $ B.) Type I - Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler(Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A,B&C above): $ Permit fee based on project valuation(see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review(40%of permit fee): $ TOTAL: $ I:\Building\Permits\FPS_PernutApp 071514.doc 2 Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 7500 SW TECH CENTER DR 110, TIGARD, OR, 97223 Commercial - Fire Protection System 999 Sprinkler final PASS - No C of O FPS2014-00170 Jeff Grove Violation Summary: Inspector Contractor