Loading...
Permit City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT EXPIRE) - . ~ Request for Permit Action ro/ZZ/y .cry TIGARD 13125 SW Hall Blvd. •Tigard,Oregon 97223 • 503-718-2439 • www.tigard-or.gov TO: CITY OF TIGARD Building Division 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503-718-2439 Fax: 503-598-1960 TigardBuildingPermits @tigard-or.gov FROM: ❑ Owner ❑ Applicant ❑ Contractor tgl City Staff Check(1)one REFUND OR Name: INVOICE TO: (Business or Individual) Mailing Address: City/State/Zip: Phone No.: P EASE TAKE ACTION FOR THE ITEM(S) CHECKED (1): ►` CANCEL/VOID PERMIT APPLICATION. �/�`� ❑ REFUND PERMIT FEES (attach copy of original receipt and provide explanation below). J ❑ INVOICE FOR FEES DUE (attach case fee schedule and provide explanation below). ❑ REMOVE/REPLACE CON'T'RACTOR ON PERMIT (do not/cancel permit). Permit#: 1�J Gk()p2C/ 3 OOO to 4 Site Address or Parcel#: /AS 94/ 660 f ley Project Name: /"f0/J/G Subdivision Name: Lot#: EXPLANATION: e.x,o, T s Al �c SST P M r 7'e---D Pa.Z Tffi 5 toJ EeT i aO ' . h<E fPAl.r c.q ,vT 'S ?Jo 4-el./Co C�2 OPE44TIPICb 11J "�N /-b2Tu9 JD ic}RiA- A/C ,P�,5,F Nst .?2-41 F�# �4. 'D<t-r1-73 4/0 /i9 Signature: [Z,Q� Date: ivl04 f�cf Print Name: --ice,,£ Q, fVD 4-A-1 .A 1 Refund Policy 1. The city's Community Development Director,Building Official or City Engineer may authorize the refund of: • Any fee which was erroneously paid or collected. • Not more than 80%of the application or plan review fee when an application is withdrawn or canceled before review effort has been expended. • Not more than 80%of the application or permit fee for issued permits prior to any inspection requests. 2. All refunds will be returned to the original payer in the form of a check via US postal service. 3. Please allow 3-4 weeks for processing refund requests. FOR OFFICE USE ONI.1 Route to S s Admin: Date ,��' B■ Route to Records: Date , ,7M, M� Refund Processed: Date 4_ By vrigM Invoice Processed: Date By Permit C t,e : EtcP Date /0 27-11 re By ■ i.. '< el Tag Added: Date By I:\Building\Forms\RegPetmitAction_092314.doc Building Permit Application ■‘ EXPIRED / J'liJ/y ,tom Commercial FOR OFFICE USE ON I 1 City of Tigard Enu Datee vex 3® Permit No.: �u��0%fdq �pe)/'" 13125 SW Hall Blvd.,Tigard,OR 9CEIV 3 Plan Review ► ' Phone: 503.718.2439 Fax: 503.598.1g"R 2 2013 Date/B : �G /;-Other Permit: TIGARD Inspection Line: 503.639.4175 Date Ready .ty: 1u' HI See Page 2 for Internet: www.tigard-or.gov CITY�TI p Notified/Method:� 01-17 i Supplemental Information TYPE; �f. Ly REQ ED DATA:l-AND 2-FAMILY 1� G ❑New construction ❑Demolition °r r' Permit fees*are based on the value of the work performed. ,11,6•1_ /no Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement 0 Other:WCF Swap Ant tit, tf 51%4. equipment,materials,labor,overhead,and the profit for the CATEGORY;OF-CONSTRUCTION + ,y. work indicated on this application. 1- 2-famil dwelling Illirf�' r ra ❑ y g ❑Commercial/industrial vita F--- '/, Valuation: $ El Accessory building 1:1 Multi-family v'r,' Number of bedrooms: 12 Master builder ®Other:WCF Swap Ant TT' Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:12394 SW Scholls Ferry Road New dwelling area: square feet City/State/ZIP:TigatekJ,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:P003932D Greenway Covered porch area: square feet Cross street/directions to job site:I-5 to exit 294 onto 99W,take ramp onto Deck area: square feet SR-217(Beaverton-Tigard Hwy)take Exit 4 onto SR 216(Scholls Ferry Rd) Other structure area: square feet l' REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: iS134BC00900 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTIOi N OF WORK work indicated on this application. Swap(6)existing antenna with(6)similar, 'dd 5 RRUs,3 TMAs and 3 Diplexers. Valuation: $520,000.00 The existing shroud case will be replaced with a 28"dia to allow the new anten Existing buildiri‘area: square feet addition width. TOTAL antennas will re IIIIII in at 6,no ground work proposed. New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:William G Davidson Type of construction: Address:8915 SW Commercial ST Occupancy groups: City/State/ZIP:Tigard,OR 97223 Existing: Phone:( ) Fax:( ) New: tgi APPLICAN°I ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name:T-Mobile West,LLC (Please rejerto fee schedule) Structural plan review fee(or deposit): Contact name:Mary Frosch,Powder River Dev Services,LLC obo FLS plan review fee(if applicable): Address:8960 NE Alderwood Dr City/State/ZIP:Portland/OR/97220 Total fees due upon application: Phone:(503)250-4639 Fax::( ) Amount received: E-mail:Mary.Froschl @T-Mobilc.com PHOTOVOLTAICSOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted Photo Voltaic Solar Panel System. I Business name:'MT Submit two(2)sets of roof plan with connection details -- and fire department access,along with the 2010 Oregon Address: �1 Solar Installation Specialty Code checklist. Permit fee(includes plan review City/State/ZIP: and administrative fees): x180.00 Phone:( ) Fax:( ) State surcharge(12%of permit fee): $21.60 CCB tic.: Total fee due upon application: $201.60 Authorized signature: _ This permit application expires if a permit is not obtained .00111111"" within 180 days after it has been accepted as complete. Print name:Mary Frosch Date:3-21-13 * Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-COM PermitApp.doc 02/24/2011 440-4613T(1 I/02/COM/WEB) 1 6 • Building Division Development Code Provision Review r 1 ci A iz n Commercial Projects - No Associated Land Use Case Building Permit No: L u P o'∎o/Z -000404 ❑ Expedited Review Project Name: Ho/7/e._(- Site Address: 1,239 q &.J o�flrkc_4 c 6 eyt y kb , Suite/Bldg #: Plans Routed: / Original Plan Submittal Date: 3/;.sit 5 Routed By: 62).19 1" Revision Submittal Date: Routed By: 2nd Revision Submittal Date: Routed By: To the Applicant: If the proposed use is not permitted within the zone, please contact the Building Division to cancel the permit application. Building Permit Technicians (503) 718-2439. If a land use is required and for all other questions, please contact the staff person listed above the Planning Review section. Staff: please check items along left only if approved. Planning Review (contact 7 at (503) 718,It/lo or hit @tigard-or.gov)_ Proposal: - v 4 -w ,� / Zoning 0...'L7 Permitted Use Yes No ❑ —/ Land Use Required: Yes ❑ No Notes: /Approved ❑ Not Approved ❑ DCPR Not Required—No DCPR Fees Due Date Routed to Building: ' ro.,L)——/3 1:\CURPLN\Masters\Development Code Provision RevievvADCPR_COM_NoLandUse.doc Rev.01/16/13 Debbie Adamski From: Debbie Adamski Sent: Thursday, April 17, 2014 8:02 AM To: Mary.Froschl@T-Mobile.com Subject: P003932D Greenway, 12394 SW Scholls Ferry Rd, BUP2013-00064 Mary, We are checking on the permits we have in our ready to issue file and the above mentioned permit has been ready to issue since 4/25/13. Please let me know if this project was cancelled or if we need to do a permit extension on it. The balance of the permit fees due are $444.75 and we will need to have a contractor identified prior issuance of the permit. If you want an extension, you will need to let us know the reason for the extension and an approximate timeframe when the permit might be picked up. Thank-you and let me know you have any questions. Debbie Adamski Senior Permit Technician City of Tigard I Community Development 13125 SW Hall Blvd.,Tigard, OR 97223 503-718-2450 1 iona393z � Gr'e �w COLLOCATION RE CE Supplemental Questionnaire Cp City of Tigard, 13125 SW Hall Blvd.,Tigard,OR 97223 MAR 2 5 2013 Phone: 503.718.2421 Fax: 503.598.1960 CITY(*TIGARD IF YOU ARE APPLYING FOR A PERMIT TO COLLOCATE ft144440911f4910N PLEASE COMPLETE THE INFORMATION BELOW. Name of Provider: T-Mobile West,LLC Property Address/Location of Collocation: 12394 SW Scholls Ferry Rd,97223 Zone: C-G Collocating antennas on: ❑ Existing tower ® Existing non-tower structure Is this a new provider? ❑ Yes ® No Ifyes, list other providers currently collocating on same tower or structure, if any: If no,indicate the previous approval(SDR,MMD or B UP#): Height of antenna(s): 48' ft. Color of antenna(s) and accommodating equipment (i.e. dishes): the base is white brick the antenna are behing a white cylinder shroud Color of existing tower or structure: white shroud-white building Will new accessory equipment be installed? ❑ Yes ® No Ifyes,please answer the following: Location of accessory equipment: ❑ Within fenced area previously approved ❑ Within existing structure ® Other location (Please describe below.) The TMAs and new antenna will be installed within the existing shroud,the TMAs will be installed behind the new antennas and the diplexers will be mounted to exterior wall behind paraphet near the equipment cabinets. No new cabinets are proposed. No landscaping proposed. Will landscaping be removed to accommodate the accessory equipment? ❑ Yes (Please describe below.) ® No No landscaping exists and none is planned. Applicant's Signature Date: 312-9—I l 3 Name Printed: Mary Frosch Phone: 503-250-4639 FOR OFFICE USE ONLY OK to i•sue sea. t. ❑ Do not issue permit. Refer to planner. � . � '/ K> ^ - /3 Plannin. Sta ature Date I:\CURPLN\Masters\CollocateAntennas.doc -- ,, Clean Water Services File Number CleanWater Services I 1W- till' Sensitive Area Pre-Screening Site Assessmititvi—/ VCD 1. Jurisdiction: ligard MAR 2 5 2013 2. Property Information (example 1S234AB01400) 3. Owner Information BVIt TIGARD Tax lot ID(s):_ Name: William Davidson lI VI,/oN 1s134bc00900 Company: Address: 8915 SW Commercial Drive#8 • Site Address: 12394 sw Scholls Ferry Road City, State,Zip: Tigard,OR 97223 ( City, State,Zip: Tigard,OR 97223 Phone/Fax: 503-349-4886 I Nearest Cross Street: 121st Street and Meadow Circle E-Mail: Unknown I 4. Development Activity(check all that apply) 5. Applicant Information ❑ Addition to Single Family Residence(rooms,deck,garage) Name: Mary Frosch ❑ Lot Line Adjustment ❑ Minor Land Partition Company: PRDS obo T-Mobile West LLC ❑ Residential Condominium ❑ Commercial Condominium Address: 8960 NE Alderwood Drive ❑ Residential Subdivision ❑ Commercial Subdivision City, State,Zip: Portland OR 97220 ❑ Single Lot Commercial 1:1 Multi Lot Commercial Other Phone/Fax: 503-250-4639 WCF swap similiar antenna,no ground work E-Mail: Mary.Froschl @T-Mobile.com 6. Will the project involve any off-site work? i.)Yes W No ❑Unknown • Location and description of off-site work 1 7. Additional comments or information that may be needed to understand your project 1 Swapping similiar antenna to existing monopole. No ground work is proposed,no work outside fence. f d This application does NOT replace Grading and Erosion Control Permits,Connection Permits,Building Permits,Site Development Permits,DEQ I 1200-C Permit or other permits as Issued by the Department of Environmental Quality,Department of State Lands and/or Department of the Army i COE. All required permits and approvals must be obtained and completed under applicable local,state,and federal law. By signing this form,the Owner or Owner's authorized agent or representative,acknowledges and agrees that employees of Clean Water Services have authority to enter the project site at all reasonable times for the purpose of inspecting project site conditions and gathering information related to the project site. I certify that I am familiar with the information contained in this document,and to the best of my knowledge and belief,this information is true,complete,and accurate. Print/Type Name Mary Frosch Print/Type Title ONLINE SUBMITTAL Date 3/13/2013 FOR DISTRICT USE ONLY ❑ Sensitive areas potentially exist on site or within 200'of the site. THE APPLICANT MUST PERFORM A SITE ASSESSMENT PRIOR TO ISSUANCE OF A SERVICE PROVIDER LETTER. If Sensitive Areas exist on the site or within 200 feet on adjacent properties,a Natural Resources Assessment Report may also be required. ❑ Based on review of the submitted materials and best available information Sensitive areas do not appear to exist on site or within 200'of the site.This Sensitive Area Pre-Screening Site Assessment does NOT eliminate the need to evaluate and protect water quality sensitive areas if they are subsequently discovered.This document will serve as your Service Provider letter as required by Resolution and Order 07-20, Section 3.02.1. All required permits and approvals must be obtained and completed under applicable local,State,and federal law. ❑ Based on review of the submitted materials and best available information the above referenced project will not significantly impact the existing or potentially sensitive area(s)found near the site,This Sensitive Area Pre-Screening Site Assessment does NOT eliminate the need to evaluate and protect additional water quality sensitive areas if they are subsequently discovered.This document will serve as your Service Provider letter as required by Resolution and Order 07-20,Section 3.02.1. All required permits and approvals must be obtained and completed under applicable local,state and federal law. A❑ his Service Provider Letteris not valid unless------CWSproved site plan(s)are attached. proposed activi y does not meet the definition of development or t e lot was platted after 9/9/95 ORS 92.040(2). NO SITE ASSESSMENT OR SERVICE PROVID' 0 U 1._ _ Reviewed by Date 0311-5/( 3) 2550 SW Hillsboro Highway • Hillsboro,Oregon 97123 • Phone:(503)681-5100 • Fax:(503)681-4439 • www.cieanwaterservices.org T • •Mobilee 8960 Alderwood Rd Portland OR 97220 111111 503-250-4639 March 21, 2013 RECEIVED TO: City of Tigard, Oregon Y g g Planning and Development MAR 252013 Building and Permit Services 13125 SW Hall Blvd �yOFr Tigard, OR 97223 GDVISbN FROM: T-Mobile West, LLC Attn: Mary Frosch, Powder River Dev. Services, OBO 8960 NE Alderwood Drive u_ ib Portland, OR 97220 /0/271/(i Phone: (503) 250-4639 RE: Site: P003932D Greenway Site Address: 12394 SW Scholls Ferry Rd-Transmittal of Documents Wireless Swap Similar Antennas behind Roof Top Stroud Table of Contents 3 copies of the following are attached for Land Use and Building Permit Review: 1 Application Form-Commercial Construction Permit 2 Application Fee-$245.64 3 Commercial Application Check List 4 Collocation Supplemental Questionnaire 5 Letter of Notice—signed by owner William G. Davidson 6 Clean Water Services—Pre-screening Site Assessment—Approval 3-13-13 7 Narrative—WCF per Sec 18.798.040 Permitted Outright 8 RF Letter w/Calcs 9 Structural Analysis CITY OF TIGARD 10 Construction Drawings Approved [ Conditionally Approved [ ] See Letter to:Follow [ I 410 Attached [ Permit Number: Mary Frosch Address: 503-250-4639 By: Date: Mary.Froschl @T-Mobile.com L the forwarded message follows Tigard FEES /9e6 25 -- 20/3 From: "Debbie Adamski" <DEBBIE @tigard-or.gov> r To: "'Mary L Frosch r" <mary.frosch @powderriverdev.com> ioN Received: 21 Jun, 12 11:57:45 AM Mary, The building permit fee for this project,valued at$20,000, would be $668.89. In addition to this fee, we also have an archive fee which is$2.00 per plan page for any pages greater than 11 x 17 and .$50 per page for any pages 11 x 17 and less. Of this permit fee, we require that plan review portion be paid at intake. The plan review portion of this fee is$245.64. Let me know if you have any questions regarding the buildin(pert -the building plan process. Debbie Adamski Sr. Permit Technician Building Division 503-718-2450 Original Message From: Dianna Howse Sent:Thursday,June 21, 2012 10:39 AM 44141 To: 'Mary L Frosch' Cc: Debbie Adamski; Cheryl Caines Subject: RE: BUILDING PERMIT and LU FEE REQUEST- Commercial Application Checklist III Ci-11 IG ty of Tigard RECE!13 125 SW Hall Blvd. Ti and OR 97223 � Phone: 503.718.2439,Fax: 503.598.1960 MAR 25 2013 `���° Internet address: www.tigard-or.gov CI ., PROJECT INFORMATION Project name: P003932D Greenway Date: 2-28-2013 Address: 12394Scholls Ferry Road City: Tigard State: OR I ZIP: 97223 Scope of work: swap 6 antenna with 6 new antenna all work on monopole no ground work proposed Reference no.: Map and tax-lot no.: 1s134bc00900 Contact person name: Mary Frosch Company: T-Mobile West, LLC Phone: 503-250-4639 Fax: Cellular phone: 503-250-4639 E-mail: Mary.Froschl @T-Mobile.com NOTES AND INSTRUCTIONS • The purpose of this checklist is to help define a complete submittal package for the scope of work. Plan review will not take place until a complete package is submitted. • This checklist can be used for all commercial construction projects, including new construction, additions, alterations and tenant improvements. • For complex projects, applicants should use the "location" space to note the item's location and page number from the plans or the specification book. • It is not necessary to duplicate submittal information, even if it is asked for in multiple sections. • In the checklist, "Required"means that the applicant must provide this information for plan review. • In the checklist, "P" means— • if checked by the applicant the information is provided for the plan review. • if checked by the plans reviewer—this information is required for the plan review. • In the checklist, "NA"means that the information does not apply. • Choose only those sections of the checklist that apply to your scope of work. Section 1.0, "General Project Data,"must be included with each .roject submitted. PRE-SUBMITTAL PROCESS An applicant may request a pre-submittal meeting with representatives of the jurisdiction in which the project will be built. The meeting may take place during the conceptual, schematic, or in-progress phase, or when the applicant has completed plans. INDEX OF CHECKLIST SECTIONS 1.0 General project data Page 2 7.0 Mechanical data(Types I and II 2.0 Civil data Page 2 kitchen-hood permits) Page 6 .0 Architectural data 3a Page 3 8.0 Plumbing data Page 7 .0 Structural data Page 4 9.0 Electrical data Page 8 .0 Mechanical data(new construction, tenant 10.0 Fire-suppression data Page 9 improvement, gas-piping permits) Page 5 11.0 Fire-detection and fire-alarm data Page 9 6.0 Mechanical data(additional or replacement 12.0 Re-roof installation data Page 10 rooftop-equipment installation permits) Page 6 13.0 Jurisdictional requirements Page 10 This checklist is for building department jurisdictions in Clackamas,Multnomah,and Washington counties. 440-2734(8/01/WEB/COM) I:\Building\Forms\COM-Checklist.doc 02/27/13 IT • •Mobile• 8960 Alderwood Rd Portland OR 97220 503-250-4639 March 20, 2013 City of Tigard RECEI V D Community Development MAR 2 5 13125 SW Hall Blvd, 2013 Tigard, OR 97223 CITY OFTIGARD BUILDING DIVISION RE: P003932D Greenway 12394 SW Scholls Ferry Road,Tigard, OR 97223 Modification to Existing Wireless Shrouded Tower To Whom It May Concern: As you may be aware,on February 22, 2012,the federal government enacted "collocation-by-right" legislation preempting delays in the process of zoning the collocation of transmission equipment on existing wireless communications. The Federal Collocation-By-Right Legislation mandates that local governments must approve any eligible facilities request for the modification of an existing wireless tower or base station that does not substantially change the physical dimensions of such tower or base station. Powder River Development Services, LLC,obo T-Mobile West, LLC, has enclosed herein the application materials required for zoning approval of the modification to the wireless facility located at 12394 SW Scholls Ferry Road,Tigard,OR 97223. Please note that: (i)the modification involves the replacement of transmission equipment; and (ii)such modification will not substantially change the physical dimensions of such tower. Under the Federal Collocation-By-Right Legislation, City of Tigard must therefore approve this request. The proposed modification complies with all federal, state, and local zoning and permitting requirements. It is our expectation that this application will be processed without any undue delay and in a manner consistent with the newly enacted Federal Collocation-By-Right Legislation. Thank you in advance for your anticipated cooperation. CIT OF TIGARD Approved Ik Conditionally Approved [ ] Regards, See Letter to:Follow [ ] Attached Mary Frosch Permit Number: (3- ] [ Ada : 2 Powder River Development Services, LLC on behalf of T-Mobile West, LLC By: Date: 8960 NE Alderwood Drive, Portland, OR 97220 503-250-4639 Approved plans shall be on job site. OFFICE COPY EXPIRED 1 P003932D Greenway io ZZ /y Network Modernization P003932D Greenway I. PROPOSAL SUMMARY INFORMATION Date: March 20, 2013 Applicant: T-Mobile West, LLC Luis Reyes, Market Manager 8960 Alderwood Drive NE Portland,OR 97220 Representative: Mary Lou Frosch Contact 8960 Alderwood Drive NE, Portland, OR 97220 Telephone: 503-250-4639 Email: marv.froschl @T-Mobile.com Property Owner: William G and Dixie Davidson 14855 SE 82nd Drive Clackamas,OR 98015 Scope of Work: T-Mobile proposes to swap(6) antenna with (6) new along and the addition of (4) stacked 8'-0" high by 28"dia.cylinder antenna shrouds. Also proposing to swap(3)TMA with (6) new TMAs and add (6) Remote Radio Units(3-FXFB, 3-FRIG). The TMAs will be installed below the antenna on existing pipe mounts. Upon completion the total number of T-Mobile antenna will remain the same at(6) antenna. No additional antennas are proposed; No ground work or landscaping is proposed and all work will be done within the leased area. The time of completion is approximately(5) days. Site Description: 1S134BC00900 Lot Size: 0.49 AC-21,344 SF Location: 12394 SW Scholls Ferry Road,Tigard, OR 97223 Zoning Classification: (C-G) General Commercial District II. PROPOSAL DESCRIPTION Pursuant to the City of Tigard's Zoning Ordinance, T-Mobile is applying for a plan review and building permit and any and all other relief necessary to make certain modifications to the existing Wireless Communications Monopole Facility located at 12394 SW Scholls Ferry Road, Tigard, OR 97223, which consists of a roof top installation The proposed modifications to the Wireless Communications Facility will be designed and constructed to meet applicable governmental and industry safety standards. T-Mobile has an existing Roof Top Wireless Facility Lease consisting of(6)antenna, (3) support cabinets and related cable runs. T-Mobile proposes to swap(6) antenna with (6) new along and the addition of(4)stacked 8'-0" high by 28" dia. cylinder antenna shroud. Also proposing to swap(3)TMA with (6) new TMAs and add (6) Remote Radio Units(3-FXFB, 3-FRIG). The TMA will be installed below the antenna on existing pipe mounts. Upon completion the total number of T-Mobile antenna will remain the same at(6) antenna. No additional antennas are proposed; No ground work or landscaping is proposed and all work will be done within the leased area. The time of completion is approximately(5) days. 2 P003932D Greenway Specifically,T-Mobile will comply with all FCC and FAA rules governing construction requirements, technical standards, interference protection, power and height limitations, and radio frequency standards. In addition,T-Mobile will comply with all applicable FAA rules on site location. Any and all RF emissions are subject to the exclusive jurisdiction of the FCC. T-Mobile expressly reserves all of its rights, including,those available to it under the City of Tigard's Planning and Zoning Ordinances or any other state, and local or Federal law. The new antenna configuration can be reviewed with the attached site plans. The new antennas will be serviced by the new and existing radio equipment cabinet located in the leased area. Landscaping: The scope of work is to swap existing antenna and related equipment on the existing roof top facility. No ground work or landscaping is planned or will be disturbed during installation. Structural Characteristics: A structural analysis will be submitted as part of the building permits process with the city of Tigard. Construction and Post-Construction Activity: T-Mobile's construction schedule spans an approximate 30 day time frames. All staging of construction equipment will occur on the subject property in conformance with a City of Tigard Structural Building Permit. The time for installation is approximately(5) days. III. DEVELOPMENT STANDARDS Section 18.520.1 Use Table: Commercial Zoning Districts B. Use table. A list of permitted, restricted, conditional and prohibited uses in commercial zones is presented in Table 18.520.1. OTHER: Wireless Communication Facility in C-G Zone District P/R(3) P/R(3)=(P) Permitted/(R) Restricted,(3) See Chapter 18.798 WCF for requirements for permitted and restricted facilities. C. Accessory structures. 1.Accessory structures are permitted in all commercial zones providing the site is still in compliance with all development standards, including but not limited to setbacks, height, lot coverage and landscaping requirements, of the base zone.All accessory structures shall comply with all requirements of the State Building Code. RESPONSE: T-Mobile is proposing an antenna swap;this is not a new facility request. A building permit application and structural analysis has been submitted with this application. 2.All freestanding and detached towers, antennas,wind-generating devices and TV receiving dishes, except as otherwise regulated by Chapter 18.798, Wireless Communication Facilities, shall have setbacks equal to or greater than the height of the proposed structure. Suitable protective anti-climb fencing and a landscaped planting screen, in accordance with Chapter . 18.745, Landscaping and Screening, shall be provided and maintained around these structures and accessory attachments. RESPONSE: T-Mobile proposes an antenna swap on a roof top with shrouded antennas;this is not a new facility request. An explanation to Chapter 18.745, Landscaping and Screening,is included further in this narrative. 3 P003932D Greenway Section 18.798 Wireless Communication Facilities 18.798.030 Exemptions • A. Exemptions. The following uses and activities shall be exempt from these regulations: 1. Existing towers and antennas and any repair, reconstruction or maintenance of these facilities which do not create a significant change in visual impact; 2. Ham radio towers, citizen band transmitters and antennas; 3. Microwave dishes; 4.Antennas and equipment and other apparatus completely located within an existing structure whose purpose is to enhance or facilitate communication function of other structures on the site. RESPONSE: T-Mobile proposes to swap 6 existing antenna with 6 new and replace the existing 8'x20" shroud with a new 8'x 28" shroud to accommodate the new antenna and maintain the lessen visual impact the shroud provides. T-Mobile meets this criterion with the minimal width increase of 8"to the shroud,all additional equipment will be painted to match or located behind the shroud. 18.798.040 Uses Permitted Outright B. Collocation of antenna(s) on existing non-tower structure in commercial and industrial zones. Installing an antenna(s)on an existing structure other than a tower, such as a building, water tank, sign, light fixture or utility pole, is permitted outright so long as the additional antenna(s)is no more than 20 feet higher than the existing structure, no more than three providers are collocating on the structure, and the color of the antenna(s)blends with the existing structure or surroundings. RESPONSE: T-Mobile proposes to swap 6 existing antenna with 6 new and replace the existing 8'x20" shroud with a new 8'x 28" shroud to accommodate the new antenna and maintain the lessen visual impact the shroud provides. T-Mobile meets this criterion with the minimal width increase of 8"to the shroud, all additional equipment will be painted to match or located behind the shroud. A completed Structural Permit Application has been submitted to the Building Department. I would like to request full approval for this proposed antenna upgrade and collocation. If I can be of any assistance, please call me at 503-250-4639, or email at Mary.Froschl @T- Mobile.corn. Sincerely, Mary Lou Frosch 8960 Alderwood Drive, Portland, OR 97220 Phone: 503-250-4639 Email: Mary.Froschl @T-Mobile.com 4 P003932D Greenway - -Mobile•- RECEIVED MAH 2 5 ZU13 August 1, 2012 CITY OF TIGARD To:The City of Portland Bureau of Development Services BUILDING DIVISION Re:Proposed radio frequency facility- P003932D (12394 SW Scholls Ferry Rd, Portland, OR,97223) Dear Planner, The proposed facility noted above will operate at the below listed frequencies,as licensed by the Federal Communications Commission. PCS Transmit Frequency(MHZ) PCS Receive Frequency(MHZ) 1930-1945 1850-1865 UMTS-AWS Transmit Frequency(MHZ) UMTS-AWS Receive Frequency(MHZ) 2145-2155 1745-1755 LTE Transmit Frequency(MHZ) LTE Receive Frequency(MHZ) 2130-2135,2135-2140 1730-1735,1735-1740 The worst case general population exposure limit per the FCC Public standards OET Bulletin 65 and in Table 274-1 of the City of Portland Zoning Code(Title 33)is 0.0095 mW/cm2 for Sector 1. 0.0091 mW/cm2 for Sector 2. 0.0105 mW/cm2 for Sector 3. The power density calculations for each sector of the proposed facility(typically less than 1 to 5%of the FCC limit)will be below the maximum FCC exposure levels,i.e.Below the 1 milliWatts/Cm2 for the uncontrolled area.The proposed facility is categorically proven as safe,according to Federal Guidelines. The proposed facility should not interfere with other communications facilities.Our sites are monitored 24/7 by a national operations center to insure all is operating normally. In addition,we have local technicians who make routine visits to cell sites to make repairs when needed. I certify that this information is true to the best of my knowledge. Re-ards b117 Gurjeet =ahl T-Mobile Engineering Manager RF Deployment 8960 NE Alderwood Rd, Portland,OR 97220 T • 'Mobile: SENT VIA CERTIFIED AND FIRST CLASS U.S.MAIL, 8960 Alderwood Rd Portland OR 97220 Mr. William G.Davidson October 2,2012 8915 SW Commercial Drive#38 PO Box 231132 Tigard,OR 97223 RILEAiNCRG503-349-4886 Cell M 25 2013 Re: T-Mobile Site#: P003932D Greenway Site Address: 12394 SW Scholls Ferry Rd CITYOFTIGARD��Consent for Modification of Antenna Facilities Modification BU DIVISION Dear Mr. William G.Davidson: T-Mobile West LLC,as successor in interest to T-Mobile West Corporation("T-Mobile")and William G. Davidson who,as of September 1,2012,is the sole successor to the interest in the TMO lease agreement dated 2002,("Landlord"),is party to a Roof Top Lease Agreement dated May 25,2002 (the"LEASE")for a site located at 12394 SW Scholls Ferry Rd,Tigard,OR 97225,upon which T-Mobile operates a wireless antenna facilities. Please be advised that T-Mobile needs to replace/upgrade the equipment on its facilities within the existing premises. This upgrade includes the removal/replacement of(6)antenna and the addition of(3)FXFB and(3) FRIG units installed within the shroud.Also we propose to add(3)Diplexers mounted to the exterior wall within the mezzanine floor close to the existing cabinets. I have attached a set of construction drawings showing these upgrades for your review. We tentatively anticipate this work to be performed during the first quarter of 2013. If you have any questions,please contact Mary Frosch at 503-250-4639. Thank you for your cooperation and attention to this matter. Sincerelyy,, Luis Reyes Market Manager T-Mobile West LLC Acknowledged,Accepted and Agreed: Landlord: ///' s ' By: Name: - �Title: .rs 71 // / Date: //&■ GPD GROUP, PC., INC. STRUCTURAL ANALYSIS REPORT TOWERS ..SITE Ntf '' • P003932D SITE NAME*Fb.. GREENWAY SITE ADDRESS: 12394 SW SCHOLLS FERRY RD PORTLAND, OR 97223 NEW ANTENNA INSTALLATION ON EXISTING 44' STEALTH MONOPOLES September 14, 2012 GPD Project #: 2012861.41 STEALTH MONOPOLES STRUCTURAL ANALYSIS REPORT P003932D GREENWAY 12394 SW Scholls Ferry Rd Portland, OR 97223 GPD Project #: 2012861.41 New Antenna Installation Existing 44 ft Stealth MonopoleS For: T-Mobile Towers Bellevue, Washington Prepared By: v�`t� PROFS 1815PE a. David B. Granger, P.E. Registered Professional Engineer Oregon #: 18155PE September 14, 2012 Glaus, Pyle, Schomer, Burns and DeHaven, Inc. dba GPD Group ENGINEERS • ARCHITECTS • PLANNERS 520 South Main Street • Suite 2531 • Akron • Ohio • 44311-1010 • Tel: 330-572-2100 • Fax: 330-572-2101 TABLE OF CONTENTS DESCRIPTION PAGE NUMBER EXECUTIVE SUMMARY 1 TOWER DESCRIPTION 2 TOWER MATERIALS 2 TOWER LOADING . 3 ANALYSIS 4 CONCLUSIONS AND RECOMMENDATIONS . 4 DISCLAIMER OF WARRANTIES 5 APPENDICES 1. TNXTOWER ANALYSIS PRINTOUT 2. TOWER ELEVATION DRAWING AND FEEDLINE PLAN 3. FLANGE BOLT AND FLANGE PLATE ANALYSIS 4. ANCHOR ROD AND BASE PLATE ANALYSIS 5. FOUNDATION ANALYSIS i■- GPD GROUP P003932D GREENWAY EXECUTIVE SUMMARY The purpose of this analysis is to verify whether the design for the existing tower is structurally capable of carrying the new antenna and coax loads as specified by T-Mobile. This report was commissioned by Mr. Chuck Meyer of T-Mobile Towers. The design for the existing structure meets the requirements of TIA-222-G and the 2010 Oregon Structural Specialty Code for a 95 mph 3-second gust wind speed with no ice and a 30 mph 3-second gust wind speed with 1-1/4" of radial ice for the proposed antenna configuration. Seismic loads were considered using a substantiated analysis utilizing the TIA-222-G standard. Based on section 2.7.3 of the TIA-222-G standard the seismic effects may be ignored due to the earthquake spectral response acceleration(Ss)for this site being less than or equal to 1.00. The wind effects control the tower loading. The foundation reactions, with the proposed loading, were found to be less than the capacity of the existing foundation design. Therefore the existing foundation is adequate, assuming it was properly constructed according to original design. Section Results Monopole % Capacity Result 28' — 44' 50.7% Pass Flange Plate @ 28' 57.6% Pass Flange Bolts @ 28' 76.9% Pass 0' — 28' 27.4% Pass Anchor Rods 36.8% Pass Base Plate 78.4% Pass Foundation % Capacity Result Structure 16.6% Pass Soil Interaction 46.3% Pass Tower Rating: 78.4% *Two towers on site are identical and Tower 1 (North Tower) was the controlling tower A /* GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 1 P003932D GREEN WAY TOWER DESCRIPTION The existing 44' stealth monopoles are located in Portland, Oregon. They were originally designed for Voicestream by Valmont Microflect of Salem, Oregon. The original design code and wind speed are • unknown. The existing stealth monopoles are identical and have two major sections. The top section consists of a 4.5"o pipe housed inside two 20"o x 8'concealment shrouds and is connected by a bolted flange joint. The bottom section is round with a constant diameter of 14". The stealth concealment shrouds were designed to shield the appurtenances from sight. The structure is galvanized and has no tower lighting. DOCUMENTS PROVIDED Description Remarks Source Foundation Drawings Valmont, Drawing #: 8-11575-2, T-Mobile dated 06/18/2002 Geotechnical Report Tower Engineering Professionals, Inc., T-Mobile Project #: 124784.10, dated 07/26/2012 Inspection Report Tower Engineering Professionals, Inc., T-Mobile TEP #: 124784, dated 08/28/2012 TOWER MATERIALS Data on steel strength was available from the information provided. The following table details the steel strength used in the analysis. Monopole ASTM A36M (42 KSI Yield Strength) Base Plate ASTM A36 (36 KSI Yield Strength) Anchor Rods ASTM F 1554 (55 KSI Yield Strength) Flange Plates ASTM A36 (36 KSI Yield Strength) Flange Bolts ASTM A325 44S GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 2 P003932D GREENWAY TOWER LOADING The following data shows the major loading that the tower supports.All existing, reserved and proposed antenna information was provided by T-Mobile Towers. Existing & Reserved Configuration TOWER 1 — NORTH TOWER Elevation Carrier Antennas 40.5' T-Mobile (3) Andrew TMBX-6516-R2M Antennas, inside two 20" o x 8' Canisters, w/ (6) 7/8" internal coax TOWER 2 — SOUTH TOWER Elevation Carrier Antennas 41' T-Mobile (3) EMS DR65-19-02-DPQ Antennas, & (3) Ericsson KRY112 89/1 TMAs, inside two 20" o x 8' Canisters, w/ (9) 7/8" internal coax Proposed Configuration TOWER 1 — NORTH TOWER Elevation Carrier Antennas 41.5' T-Mobile (3) Andrew TMBXX-6516-R2M Antennas, ` (6) Andrew ETM190VS12UB TMAs, ! r``� '!i & (3) Andrew Twin PCS TMAs, v . inside two 20" o x 8' Canisters, w/ (12) 7/8" internal coax TOWER 2 — SOUTH TOWER Elevation Carrier Antennas 33.5' T-Mobile (3) Andrew TMBXX-6516-R2M Antennas, & (6) Andrew Twin AWS TMAs, inside two 20" o x 8' Canisters, w/ (12) 7/8" internal coax Notes: - The elevation given is for the top of the antenna -TMAs are to be installed in the upper and/ or lower canisters - See Appendix 2 for feedline plan. The purpose of this independent structural analysis review is to determine if the design for the existing tower, with the proposed configuration, is in conformance to the latest TIA-222-G and 2010 OSSC standard requirements. ••■ GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 3 P003932D GREENWAY ANALYSIS The purpose of this structural analysis review is to determine if the design for the existing tower is in conformance to the latest TIA-222-G and 2010 OSSC standard requirements. TnxTower (Version v6.0.4.0), a commercially available software program,was used to create a three-dimensional model of the tower and calculate member stresses for various dead, live,wind,and ice load cases. All loads were computed in accordance with the TIA-222-G and all local building code requirements. Selected output from the analysis is included in Appendix 1. The current requirements of TIA-222-G and the 2010 OSSC are for a 95 mph 3-second gust wind speed with no ice and a 30 mph 3-second gust wind speed with 1-1/4" radial ice. The 2010 OSSC requires towers at this location within Washington County, Oregon to be analyzed with a 95 mph wind speed. ANALYSIS 3-SECOND GUST: 95 MPH ANALYSIS 3-SECOND GUST WITH ICE: 30 MPH RADIAL ICE: 1-1/4" STRUCTURE CLASS: II IMPORTANCE FACTOR: 1 TOPOGRAPHIC CATEGORY: 1 EXPOSURE CATEGORY: C 1-SECOND SPECTRAL RESPONSE ACCELERATION (Si): 0.338 SHORT PERIOD SPECTRAL RESPONSE ACCELERATION (Ss): 0.934 The tower and foundations are assumed, for the purpose of this analysis, to have been properly fabricated, constructed, maintained,and to be in good condition with no structural defects. This is not a condition assessment of the tower, and has been provided without the benefit of recent detailed site photos, a detailed tower mapping or a GPD Group site visit. This analysis assumes that all antennas and coax have been installed in a neat and orderly fashion. The antennas are assumed to have been installed on standard mounts at 120° azimuths. The existing/proposed mounts are assumed to have been verified by the carrier to support the existing/proposed loading for the required various load cases. CONCLUSIONS AND RECOMMENDATIONS Based on the computer structural analysis results,the design for the existing 44'stealth monopole meets the requirements of TIA-222-G and the 2010 OSSC for a 95 mph 3-second gust wind speed with no ice and a 30 mph 3-second gust wind speed with 1-1/4" radial ice for the proposed antenna configuration. The foundation reactions, with the proposed loading, were found to be less than the capacity of the existing foundation design. Therefore the existing foundation is adequate, assuming it was properly constructed according to original design. Summary of Findings Monopole Satisfactory Flange Plate Satisfactory Flange Bolts Satisfactory Base Plate Satisfactory Anchor Rods Satisfactory Foundation Satisfactory Therefore, based on our analysis results,the design for the existing structure is structurally satisfactory for the proposed loading configuration. .4e:edo- GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 4 P003932D GREENWAY DISCLAIMER OF WARRANTIES GPD GROUP has not performed a site visit to the tower to verify the member sizes or antenna/coax loading. If the existing conditions are not as represented on the tower elevation contained in this report, we should be contacted immediately to evaluate the significance of the discrepancy. This is not a condition assessment of the tower or foundation. This report does not replace a full tower inspection. The tower and foundations are assumed to have been properly fabricated, erected, maintained, in good condition, twist free, and plumb. The engineering services rendered by GPD GROUP in connection with this Structural Analysis are limited to a computer analysis of the tower structure and theoretical capacity of its main structural members. All tower components have been assumed to only resist dead loads when no other loads are applied. No allowance was made for any damaged, bent, missing, loose, or rusted members (above and below ground). No allowance was made for loose bolts or cracked welds. GPD GROUP does not analyze the fabrication of the structure(including welding). It is not possible to have all the very detailed information needed to perform a thorough analysis of every structural sub-component and connection of an existing tower. GPD GROUP provides a limited scope of service in that we cannot verify the adequacy of every weld, plate connection detail, etc. The purpose of this report is to assess the feasibility of adding appurtenances usually accompanied by transmission lines to the structure. It is the owner's responsibility to determine the amount of ice accumulation in excess of the specified code recommended amount, if any, that should be considered in the structural analysis. The attached sketches are a schematic representation of the analyzed tower. If any material is fabricated from these sketches, the contractor shall be responsible for field verifying the existing conditions, proper fit, and clearance in the field. Any mentions of structural modifications are reasonable estimates and should not be used as a precise construction document. Precise modification drawings are obtainable from GPD GROUP, but are beyond the scope of this report. Miscellaneous items such as antenna mounts, etc., have not been designed or detailed as a part of our work. We recommend that material of adequate size and strength be purchased from a reputable tower manufacturer. GPD GROUP makes no warranties, expressed and/or implied, in connection with this report and disclaims any liability arising from material, fabrication, and erection of this tower. GPD GROUP will not be responsible whatsoever for, or on account of, consequential or incidental damages sustained by any person,firm,or organization as a result of any data or conclusions contained in this report. The maximum liability of GPD GROUP pursuant to this report will be limited to the total fee received for preparation of this report. ��� GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 5 P003932D GREENWAY APPENDICES 1. TnxTower Analysis Printout 2. Tower Elevation Drawing and Feedline Plan 3. Flange Bolt and Flange Plate Analysis 4. Anchor Rod and Base Plate Analysis 5. Foundation Analysis %�∎- GPD GROUP TNXTOWER ANALYSIS PRINTOUT 49";:o- GPD GROUP Page• tnxTower P003932D GREENWAY(TOWER 1 - NORTH) 1 of 4 GPD Group Project Date 520 South Main St.Suite 2531 2012861.41 09:31:50 09/14/12 • Akron,OH 44311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX (220)572-2101 kryan Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Washington County,Oregon. Basic wind speed of 95 mph. Structure Class II. Exposure Category C. Topographic Category 1. Nominal ice thickness of 1.2500 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50°F. Deflections calculated using a wind speed of 60 mph. A non-linear(P-delta)analysis was used. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads,feedline supports,and appurtenance mounts are not considered. Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total C,AA Weight or Shield Type Number Leg ft fis/ft plf LDFS-50A(7/8 FOAM) C No Inside Pole 41.50-17.00 12 No Ice 0.00 0.33 1/2"Ice 0.00 0.33 1"Ice 0.00 0.33 2"Ice 0.00 0.33 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement C4A,1 CaA.a Weight or Type Horr Adjustment Front Side Leg Lateral Vert ft ft fts ft2 lb ft ft EEI 20"dia x 8'Enclosure C None 0.0000 40.00 No Ice 10.67 10.67 406.000 1/2"Ice 11.32 11.32 517.407 1"Ice 11.98 11.98 635.889 2"Ice 13.33 13.33 894.692 EE120"dia x 8'Enclosure C None 0.0000 32.00 No Ice 10.67 10.67 406,000 1/2"Ice 11.32 11.32 517.407 1"Ice 11.98 11.98 635.889 2"Ice 13.33 13.33 894.692 TMBXX-6516-R2M A From Leg 0.50 0.0000 41.50 No Ice 0.00 0.00 34.600 0.00 1/2"Ice 0.00 0.00 74.363 0.00 1"Ice 0.00 0.00 119.324 2"Ice 0.00 0.00 225.618 TMBXX-6516-R2M B From Leg 0.50 0.0000 41.50 No Ice 0.00 0.00 34.600 0.00 1/2"Ice 0.00 0.00 74.363 Job Page m xTower P003932D GREENWAY(TOWER 1 -NORTH) 2 of 4 GPD Group Project Date 520 South Main St.Suite 2531 2012861.41 09:31:50 09/14/12 • Akron,OH 44311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX (220)572-2101 kryan Description Face Offset Offsets: Azimuth Placement C,A,4 CAA,' Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ft ft' fie lb ft ft 0.00 1"Ice 0.00 0.00 119.324 2"Ice 0.00 0.00 225.618 TMBXX-6516-R2M C From Leg 0.50 0.0000 41.50 No Ice 0.00 0.00 34.600 0.00 1/2"Ice 0.00 0.00 74.363 0.00 1"Ice 0.00 0.00 119.324 2"Ice 0.00 0.00 225.618 Twin PCS/AWS A From Leg 0.50 0.0000 37.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 ETM190VS12UB B From Leg 0.50 0.0000 37.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 16.302 0.00 I"Ice 0.00 0.00 23.185 2"Ice 0.00 0.00 42.473 ETM190VS12UB C From Leg 0.50 0.0000 37.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 16.302 0.00 1"Ice 0.00 0.00 23.185 2"Ice 0.00 0.00 42.473 ETM190VS12UB A From Leg 0.50 0.0000 34.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 16.302 0.00 1"Ice 0.00 0.00 23.185 2"Ice 0.00 0.00 42.473 Twin PCS/AWS B From Leg 0.50 0.0000 34.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 ETM190VS12UB C From Leg 0.50 0.0000 34.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 16.302 0.00 1"Ice 0.00 0.00 23.185 2"Ice 0.00 0.00 42.473 ETM190VS12UB A From Leg 0.50 0.0000 31.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 16.302 0.00 1"Ice 0.00 0.00 23.185 2"Ice 0.00 0.00 42.473 ETM190VS12UB B From Leg 0.50 0.0000 31.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 16.302 0.00 1"Ice 0.00 0.00 23.185 2"Ice 0.00 0.00 42.473 Twin PCS/AWS C From Lcg 0.50 0.0000 31.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° LI 44-28 1.931 39 0.4785 0.0000 L2 28-0 0.583 39 0.1602 0.0000 - Page • tnxTower P0039320 GREENWAY(TOWER 1 -NORTH) 3 of 4 GPD Group Project Date 520 South Main St.Suite 2531 2012861.41 09:31:50 09/14/12 • Akron,OH 44311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX.:(220)572-2101 kryan • Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in Jr 41.50 TMBXX-6516-R2M 39 1.692 0.4225 0.0000 8874 40.00 EEI 20"dia x 8'Enclosure 39 1.551 0.3893 0.0000 8874 37.00 Twin PCS/AWS 39 1.276 0.3247 0.0000 6338 34.00 ETM190VS12UB 39 1.018 0.2639 0.0000 4437 32.00 EEI 20"dia x 8'Enclosure 39 0.859 01263 0.0000 3701 31.00 ETM190VS12UB 39 0.785 0.2085 0.0000 3435 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° LI 44-28 8.473 2 2.0989 0.0000 L2 28-0 2.557 2 0.7029 0.0000 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 41.50 TMBXX-6516-R2M 2 7.425 1.8532 0.0000 2027 40.00 EEI 20"dia x 8'Enclosure 2 6.804 1.7076 0.0000 2027 37.00 Twin PCS/AWS 2 5.598 1.4242 0.0000 1447 34.00 ETM190VS12UB 2 4.467 1.1575 0.0000 1013 32.00 EEI 20"dia x 8'Enclosure 8 3.771 0.9926 0.0000 845 31.00 ETM190VS12UB 2 3.443 0.9147 0.0000 784 Compression Checks Pole Design Data Section Elevation Size L L„ Kl/r A P„ $P„ Ratio No. P. ft ft ft in2 lb lb SP" LI 44-28(1) P4.5x0.337 16.00 0.00 0.0 4.4074 -1553.810 166601.000 0.009 L2 28-0(2) P14 SCH 20 28.00 0.00 0.0 13.4167 -3155.190 507150.000 0.006 Pole Bending Design Data Section Elevation Size M $M Ratio M,. +M,ry Ratio No. Al., M„,, ft 16-fi lb-ft y lb-ft lb-ft $M, LI 44-28(1) P4.5x0.337 9169.00 18437.42 0.497 0.00 1 8437.42 0.000 L2 28-0(2) P14 SCH 20 49231.92 184170.83 0.267 0.00 184170.83 0.000 Job Page tnxTower P003932D GREENWAY(TOWER 1 - NORTH) 4 of 4 GPD Group Project Date 520 South Main St.Suite 2531 2012861.41 09:31:50 09/14/12 • Akron,OH 44311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX:(220)572-2101 kryan Pole Shear Design Data Section Elevation Sire Actual $V Ratio Actual .T Ratio No. V V T. T ft lb lb 4V lb-ft lb ft .T LI 44-28(1) P4.5x0.337 1115.400 83300.602 0.013 0.00 26909.42 0.000 L2 28-0(2) P14 SCH 20 1737.950 253575.000 0.007 0.00 282945.00 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. P, M Mh, V. T Stress Stress ft 4,P. QM tit M, 4 V $T Ratio Ratio LI 44-28(1) 0.009 0.497 0.000 0.013 0.000 0.507 1.000 482 I' I✓ L2 28-0(2) 0.006 0.267 0.000 0.007 0.000 0.274 1.000 4.8.2 I✓ Section Capacity Table Section Elevation Component Size Critical P °P,n,,. % Pass No. ft Type Element lb lb Capacity Fail LI 44-28 Pole P4.5x0.337 1 -1553.810 166601.000 50.7 Pass L2 28-0 Pole P14 SCH 20 2 -3155.190 507150.000 27.4 Pass Summary Pole(LI) 50.7 Pass RATING= 50.7 Pass Job Page tnxTower P003932D GREENWAY(TOWER 2-SOUTH) 1 of 4 GPD Group Project Date 520 South Main St.Suite 2531 2012861.41 09:36:52 09/14/12 Akron,OH 44311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX:(220)572-2101 kryan Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Washington County,Oregon. Basic wind speed of 95 mph. Structure Class II. Exposure Category C. Topographic Category 1. Nominal ice thickness of 1.2500 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50°F. Deflections calculated using a wind speed of 60 mph. A non-linear(P-delta)analysis was used. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads,feedline supports,and appurtenance mounts are not considered. Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg ft f?/l pf LDF5-50A(7/8 FOAM) C No Inside Pole 41.00-17.00 12 No Ice 0.00 0.33 1/2"Ice 0.00 0.33 I"Ice 0.00 0.33 2"Ice 0.00 0.33 Discrete Tower Loads Description Face Offset Offsets: A:imuth Placement CAAA CAAA Weight or Type Hor- Adjustment Front Side Leg Lateral Vert ft ft fie ft' lb f ft EE120"dia x 8'Enclosure C None 0.0000 40.00 No Ice 10.67 10.67 406.000 1/2"Ice 11.32 11.32 517.407 1"Ice 11.98 11.98 635.889 2"Ice 13.33 13.33 894.692 EEl 20"dia x 8'Enclosure C None 0.0000 32.00 No Ice 10.67 10.67 406.000 1/2"Ice 11.32 11.32 517.407 1"Ice 11.98 11.98 635.889 2"Ice 13.33 13.33 894.692 TMBXX-6516-R2M A From Leg 0.50 0.0000 33.50 No Ice 0.00 0.00 34.600 0.00 1/2"Ice 0.00 0.00 74.363 0.00 1"Ice 0.00 0.00 119.324 2"Ice 0.00 0.00 225.618 TMBXX-6516-R2M B From Leg 0.50 0.0000 33.50 No Ice 0.00 0.00 34.600 0.00 1/2"Ice 0.00 0.00 74.363 Page tnxTower Job P003932D GREENWAY(TOWER 2 - SOUTH) 2 of 4 GPD Group Project Date 520 South Main St.Suite 2531 2012861.41 09:36:52 09/14/12 Akron.OH 44311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX:(220)572-2101 kryan Description Face Offset Offsets: A:imurh Placement (',.L, CAAA Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ft ft2 jt' lb jt ft 0.00 1"Ice 0.00 0.00 119.324 2"Ice 0.00 0.00 225.618 TMBXX-6516-R2M C From Leg 0.50 0.0000 33.50 No Ice 0.00 0.00 34.600 0.00 1/2"Ice 0.00 0.00 74.363 0.00 1"Ice 0.00 0.00 119.324 2"Ice 0.00 0.00 225.618 TWIN AWS A From Leg 0.50 0.0000 37.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 TWIN AWS B From Leg 0.50 0.0000 37.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 TWIN AWS C From Leg 0.50 0.0000 37.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 TWIN AWS A From Leg 0.50 0.0000 30.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 TWIN AWS B From Leg 0.50 0.0000 30.00 No Ice 0.00 0.00 11.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 TWIN AWS C From Leg 0.50 0.0000 30.00 No Ice 0.00 0.00 1 1.000 0.00 1/2"Ice 0.00 0.00 15.827 0.00 1"Ice 0.00 0.00 22.158 2"Ice 0.00 0.00 40.108 Maximum Tower Deflections - Service Wind Section Elevation Holz. Gov. Tilt Twist No. Deflection Load ft in Comb. 0 0 Ll 44-28 1.925 42 0.4762 0.0000 L2 28-0 0.582 42 0.1600 0.00uu Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 40.00 EEI 20"dia x 8'Enclosure 42 1.546 0.3876 0.0000 8919 37.00 TWIN AWS 42 1.272 0.3234 0.0000 6371 33.50 TMBXX-6516-R2M 42 0.975 0.2534 0.0000 4247 32.00 EEI 20"dia x 8'Enclosure 42 0.858 0.2256 0.0000 3719 30.00 TWIN AWS 42 0,712 0.1911 0.0000 3251 • • Job Page • tnxTower P003932D GREENWAY(TOWER 2-SOUTH) 3 of 4 GPD Croup Project Date 520 South Main Si.Suite 2531 2012861.41 09:36:52 09/14/12 Akron,OH 44311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX:(220)572-2101 kryan Maximum Tower Deflections - Design Wind Section Elevation Nor:. Gov. Tilt I;uv No. Deflection Load ft in Comb. ° LI 44-28 8.440 8 2.0869 0.0000 L2 28-0 2.554 8 0.7016 0.0000 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 40.00 EEI 20"dia x 8'Enclosure 8 6.780 1.6986 0.0000 2039 37.00 TWIN AWS 8 5.580 1.4175 0.0000 1456 33.50 TMBXX-6516-R2M 8 4.276 1.1110 0.0000 971 32.00 EEI 20"dia x 8'Enclosure 8 3.761 0.9892 0.0000 850 30.00 TWIN AWS 8 3.124 0.8381 0.0000 743 Compression Checks I Pole Design Data I Section Elevation Size L L„ K!r A P. •P, Ratio No. P. ft ft ft in. lb lb 4)P„ LI 44-28(1) P4.5x0.337 16.00 0.00 0.0 4.4074 -1511.880 166601.000 0.009 L2 28-0(2) P14 SCH 20 28.00 0.00 0.0 13.4167 -3113.210 507150.000 0.006 Pole Bending Design Data I Section Elevation Size M. 04, Ratio Mn. OA, Ratio No. M My ft lb-ft lb ft +M, lb-ft lb-ft +Mm LI 44-28(1) P4.5x0.337 9126.25 18437.42 0.495 0.00 18437.42 0.000 L2 28-0(2) PI4 SCH 20 49179.50 184170.83 0.267 0.00 184170.83 0.000 Pole Shear Design Data I Section Elevation Size Actual +V Ratio Actual $T, Ratio No. V. V T T. ft lb lb +V lb-ft lb-ft QT LI 44-28(1) P4.5x0.337 1 114 740 83300.602 0.013 0.00 26909.42 0.000 L2 28-0(2) P14 SCH 20 1737.930 253575.000 0.007 0.00 282945.00 0.000 Page tnxTower PO03932D GREENWAY(TOWER 2-SOUTH) 4 of 4 GPD Group Project Date 520 South Main St.Suite 2531 2012861.41 09:36:52 09/14/12 Akron,01144311 Client Designed by Phone:(330)572-2100 T-Mobile Towers FAX:(220)572-2101 kryan Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. P„ M M. Y T Stress Stress ft +P. all, +M,, +y +T Ratio Ratio L 1 44-28(1) 0.009 0.495 0.000 0.013 0.000 0.504 1.000 482 ✓ V L2 28-0(2) 0.006 0.267 0.000 0.007 0.000 0.273 1.000 4.8.2 ✓ V Section Capacity Table I Section Elevation Component Size Critical P oPal, % Pass No. ft Type Element lb lb Capacity Fail LI 44-28 Pole P4.5x0.337 1 -1511.880 166601.000 50.4 Pass L2 28-0 Pole P14 SCH 20 2 -3113.210 507150.000 27.3 Pass Summary Pole(LI) 50.4 Pass RATING— 50.4 Pass TOWER ELEVATION DRAWING AND FEEDLINE PLAN • 4/*- GPD GROUP I • 44.08 • DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION TMBXX-6516-R2M 41.5 ETM190VS12UB 34 TMBXX-6518-R2M 41.5 TWIn PCSIAWS 34 TMBXX-6518-1,12M 41.5 ETM190VS12UB 34 EEI 20'Ma x 8'Enclosure 40 EEI 20-die x 8'Enclosure 32 Twin PCS/AWS 37 ETM190VS12UB 31 ETM190VS12UB 37 ETM190VS12UB 31 ETM190VS12UB 37 --TW1n PCS/AWS 31 F. MATERIAL STRENGTH a GRADE Fy Fu GRADE I Fy Fu A36M-42 42 ksi 60 ksi TOWER DESIGN NOTES 1. Tower is located in Washington County,Oregon. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 95 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 1.25 in ice.Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 28.0 6 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING:50.7% 0 N � 8 + N � a ALL REACTIONS ARE FACTORED AXIAL 7310 lb SHEAR MOMENT 213 lb 5586!b-ft 30 mph WIND-1.2500 in ICE AXIAL 3156 lb SHEAR MOMENT 1736 lb 492321b-ft 0.0 6 REACTIONS-95 mph WIND a a I N J — GPD Group Job:PO03932D GREENWAY(TOWER 1-NO RTH) /�. 520 South Main St. Suite 2531 '0'2012861.41 t;ntt3'<et.a' Akron, OH 44311 client T-Mobile Towers °r"nbrkryan APO: GPO Group Phone:(330)572-2100 code' TIA-222-G 081e'09/14/12 Sege: NTS FAX:(220)572-2101 P8th °"p No.E-1 C 4hersNmn1DeOloo l201205141..TUVrTOON32D(REE IWN3'ROWER 1.N(RTM� 0000 0000 0000 -"\„,_ 7/8"Coax for(T-Mobile) 'MN COAX PLACEMENT o NOT TO SCALE --1 JOB NO. 4051 P003932D GREENWAY TOWER 1 - NORTH 2012861 .41 GPD GROUP. DATE 520 South Main Sueet,Su rte 25 31 09/14/2012 BY Akron,Ohio 44311 DRAWN 330-572-2100 Fax 330-572.2101 K P R • 44.0 n DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION EEI 20"dia x 8'Enclosure 40 TMBXX-8516-R2M 33.5 TWIN AWS 37 EEI 20"dia x 8'Enclosure 32 TWIN AWS 37 TWIN AWS 30 TWIN AWS 37 TWIN AWS 30 TMBXX-6516-R2M 33.5 TWIN AWS 30 • TMBXX-8516-R2M 33.5 re or r MATERIAL STRENGTH e GRADE Fy Fu GRADE 1 Fy ] Fu a A36M-42 42 ksi 60 ksi TOWER DESIGN NOTES 1. Tower is located in Washington County,Oregon. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 95 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 1.25 in ice.Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.00 ft 28.06 8. TOWER RATING:50.4% 0 x0 N U o m N roi a ALL REACTIONS ARE FACTORED AXIAL 7090 lb SHEAR 7 \ MOMENT 2131b rr 55451b-ft 30 mph WIND-1.2500 in ICE AXIAL 3114 lb SHEAR MOMENT 17361b 49180 lb-ft 0.08 REACTIONS-95 mph WIND pN v 6 N GPD Group Jab:P003932D GREENWAY(TOWER 2-SOUTH) /Ap, 520 South Main St. Suite 2531 Prey 2012861.41 1:Jr)taxxn' Akron,OH 44311 O11eM.T-Mobile Towers Drawn Dj kryan Appd: GPD Group Phone:(330)572-2100 cede TIA-222-G Dale:09/14/12 $08le: NTS ( FAX:(220)572-2101 Palo 'Ec ,w..�wa2OI2 r4mTO*eww%32Q a ,Vfrwe2 SCUTWI • 0000 0000 0000 7/8"Coax for(T-Mobile) tlh14. COAX PLACEMENT NOT TO SCALE _ JOB NO. P003932D GREENWAY TOWER 2 - SOUTH\ c2012861 .41� GPD GROUP. DATE 520 South aln,StreetUYYe253 09/14/2012 BY 520 South Main Street,Sutte 2531 Akron,Ohio 44311 DRAWN 330-572-2100 For 330-572-2101 r K P R i FLANGE BOLT AND FLANGE PLATE ANALYSIS ��� GPD GROUP FLANGE BOLT AND SPOKED FLANGE PLATE CALCULATIONS @ 28 ft P003932D GREENWAY TOWER 1-NORTH • 2012861.41 RISA Reactions Bolt Information Plate Information Moment(M) 49.23 k-ft Diameter: 0.75 In Diameter: 20 In Axial(P) 3.16 kips Bolt Circle: 8.5 in Thickness: 1 in Shear(V) 1.74 kips it of Bolts 4 F5: 36 ksi Bolt Type A325 e: 2 in F„: 120 ksi w: 13.45 in 4 = 0.75 &= 0.75 F.= 120.00 ksi A5= 0.44 in2 A„= 13.450 in2 /i5R,,,= 17.89 kips 4sR„= 1210.50 kips Vie= 0.43 kips T,a= 930.41 kips --4 l• • 1..**:-..._ '� • Flange Bolt Capacity: •cr , .f I=n[(de/2V/4+(BC)78)= 36.27 in' - �, Max Comp on Bolt= 31.38 kips ,^., ,,alt?�- - . �� Shear Capacity= 2.4% 1 ` 1 f' Tensile Capacity= 76.9% 1 ,• 1 \\\ Interaction Capacity= 59.1% 11 ./ t •` Bolt Capacity 76.9%OK 1 - ---- \ \ Flange Plate: \ �,re.-'N. f'. ..'��j.) Z= 3.36 in3 s L^ •�,` •J "•'1, I� 1`\ M„= 62.752•k-in / ¢M„= 108.95_k-in 1, ..-4+*.- ,/� ✓^ ' '5: Upper Plate Capacity=1 57.6%IOK `.- tr ' .rte . \if r.re. FLANGE BOLT AND SPOKED FLANGE PLATE CALCULATIONS @ 28 ft P003932D GREENWAY TOWER 2-SOUTH 2012861.41 RISA Reactions Bolt Information Plate Information Moment(M) 49.18 k-ft Diameter: 0.75 in Diameter: 20 In Axial(P) 3.11 kips Bolt Circle: 8.5 in Thickness: 1 in Shear(V) 1.74 kips B of Bolts 4 Fr: 36 ksi Bolt Type A325 e: 2 in F,,: 120 ksi w: 13.45 in 4i.= 0.75 Ih,= 0.75 F,5= 120.00 ksi Ae= 0.44 in2 An= 13.450 in2 4iRm= 17.89 kips ¢Ra= 1210.50 kips V,e= 0.43 kips T, = 929.44 kips - -b:}- . 1�• ,.e.. Flange Bolt Capacity: tw . ~.% .I I=n((db/2)2/4+(BC)2/8)= 36.27 in0 �' . �• ` . . 1 Max Comp on Bolt= 31.33 kips 71.. 1A.. r/: �\ Shear Capacity= 2.4% ~r' 1 .. ,# 4 444 Tensile Capacity= 76.8% ; ,, :� h t Interaction Capacity= 59.0% C `� \\` Bolt Capacity= 76.8%_OK , �� •::vy: '. ; Flange Plate: \ ,,...• r� -. ti ! \` Z= 3.36 in3 \ �,- ,r` M„= 62.666 k-in \ `�.. i. eM„= 108.95k-in ...4 r' �� Upper Plate Capacity=I 57.5%1C. \ w. .tr �� \e,...'"'' . T ANCHOR ROD AND BASE PLATE ANALYSIS • �■ GPD GROUP • Anchor Rod and Base Plate Stresses, TIA-222-G-1 ''I P003932D GREENWAY TOWER 1 - NORTH 2012861.41 GPD GROUP • Overturning Moment= 49.23 kit Axial Force= 3.16 k Acceptable Stress) Shear Force= 1.74 k I Ratio= 105.0%1 Anchor Rods Base Plats (Section 4.9.9. TIA-222-G-1) Location= External Number of Rods= 4 Plate Strength(Fy)= 36 ksi (1)= 0.8 = 0.9 Rod Ultimate Strength(Fu)= 75 ksi Outside Diameter= 24 in Base Plate Detail Type*= d Plate Thickness= 1 in Rod Circle= 20 in wcalc= 14.28 in Rod Diameter= 1.5 in wmax= 10.00 in Net Tensile Area= 1.41 in2 w= 14.28 in Max Tension on Rod= 28.67 kips Z= 3.57 in3 Max Compression on Rod= 30.25 kips M.= 90.74 k-in Pu= 30.25 kips (PM,,= 115.69 k-in Vu= 0.43 kips ( BP Capacity= 78.4% OK 0= 0.50 (PRnt= 84.60 kips Pole Anchor Rod Capacity= 36.8% OK Pole Diameter= 14 in Number of Sides= Round *This analysis assumes the clear distance Thickness= 0.36 in from the top of the concrete to the bottom of Pole Yield Strength= 42 ksi the leveling nut is less than the diameter of the anchor rod. Notify GPD Group immediately if existing field conditions do not meet this assumntion Stiffeners Configuration=1 None] GPD Round Base Plate Stress(Rev G)-V1.07a �► Anchor Rod and Base Plate Stresses, TIA-222-G-1 '''_ P003932D GREENWAY TOWER 2 - SOUTH 2012861.41 GPD GROUP Overturning Moment= 49.18 k`ft Axial Force= 3.11 k Acceptable Stress Shear Force= 1.74 k Ratio=1 105.0%1 Anchor Rods Base Plate (Section 4.9.9, TIA-222-G-1) Location= External Number of Rods= 4 Plate Strength(Fy)= 36 ksi = 0.8 4= 0.9 Rod Ultimate Strength(F„)= 75 ksi Outside Diameter= 24 in Base Plate Detail Type*= d Plate Thickness= 1 in Rod Circle= 20 in wcalc= 14.28 in Rod Diameter= 1.5 in wmax= 10.00 in Net Tensile Area= 1.41 in2 w= 14.28 in Max Tension on Rod= 28.65 kips Z= 3.57 in3 Max Compression on Rod= 30.20 kips M„= 90.61 k-in P„= 30.20 kips <PMn= 115.69 k-in V„= 0.43 kips BP Capacity= 78.3% OK = 0.50 pRnt= 84.60 kips Pole Anchor Rod Capacity= 36.7% OK Pole Diameter= 14 in • Number of Sides= Round This analysis assumes the clear distance Thickness= 0.36 in from the top of the concrete to the bottom of Pole Yield Strength= 42 ksi the leveling nut is less than the diameter of the anchor rod. Notify GPD Group immediately if existing field conditions do not meet this assumntinn Stiffeners Configuration=1 None' GPD Round Base Plate Stress(Rev G)-V1.07a FOUNDATION ANALYSIS A/'� GPD GROUP I. Caisson Analysis edit+ P003932D GREENWAY TOWER 1 -NORTH P GPD GROUP 2012861.41 51 t General Info Soil Summary(Req.F5=1.33) - , . Code TIA-222-G Mu= 49.23 k-ft . Concrete Code ACI 318-08 Mr= 141.42 k-ft Seismic Design Category FS= 2.87 _ . Max Stress Ratio 1.05 Capacity= 46.3% Pass Reinforcing Known? Yes Modified? No General Soil Reinforcing Summary Ground Water 11.00 ft 4,Mn= 378.50 4 ft Soil Depth to Neglect 3.00 ft Mu= 63.00 4 ft Min p= 0.00500 Reactions Provided p= 0.00589 (,c D Moment,M 49.23 k-ft Capacity= 16.6% Pass , Axial,P 3.16 k Shear,V 1.74 k 1 ' Pier Information 1 Pier Diameter 3 ft Pier Length Below Grade 9 ft Distance Above Grade 4 5 ft . Vertical Bar Size #9 Vertical Bar Quantity 6 , -4 Tie Size #4 ft "S Y, fc'= 3 ksi _ _ _ _ : • f9= 60 ksi Clear Cover= 3 in Soil Info Layer Soil Type Thickness 0,Pd Cu,psf dr Kp Top of Layer Bot.of Layer Layer 1 Sand 3.5 114 0 32 3.25 0.00 3.50 Layer 2 Clay 2.5 113 1000 0 0,00 3.50 6.00 Layer 3 Clay 2.5 113 900 0 0.00 6.00 8.50 Layer 4 Sand 2.5 114 0 30 3.00 8.50 11.00 Layer 5 Sand 7.5 114 0 31 3.12 11.00 18.50 Layer 6 Sand 1.00 18.50 18.50 Layer 7 Sand 1.00 18.50 18.50 Layer 8 Clay 0.00 18.50 18.50 Layer 9 Sand 1.00 18.50 18.50 i Layer 10 Clay 0.00 18.50 18.50 GPO Caisson Analysis•V1.00 1 Caisson Analysis .40/101110.■ PO03932D GREENWAY TOWER 2-SOUTH P • GPD GROUP 2012861.41 / `tit General Info Soil Summary(Req.F5=1.33) . Code TIA-222-G Mu= 49.18 k-ft • Concrete Code AO 318-08 Mr= 141.27 k-ft l. Seismic Design Category FS= 2.87 . Man Stress Ratio 1.05 Capacity= 46.3% Pass Reinforcing Known? Yes I Modified? No . General Soil Reinforcing Summary Ground Water 11.00 ft t Mn= 378.45 k-ft Soil Depth to Neglect 3.00 ft Mu= 62.94 k-ft • Min p= 0.00500 Reactions Provided p= 0.00589 OK ;., D Moment,M 49.18 k-ft Capacity= 16.6% Pass . 41 Axial,P 3.11 k - Shear,V 1.74 k ,,;`ti •Pier Information Pier Diameter 3 ft Pier Length Below Grade 9 ft Distance Above Grade 4.5 ft ,j Vertical Bar Size 6 9 i Vertical Bar Quantity 6 -d Tie Size 0 4 ft fc'= 3 ksi --.. fy= 60 ksi , . Clear Cover= 3 in Soil Info Layer Soil Type Thickness G.Pct Cu,psf 4 Kp Top of layer Bot.of Layer Layer 1 Sand 3.5 114 0 32 3.25 0.00 3.50 Layer 2 Clay 2.5 113 1000 0 0.00 3.50 6.00 Layer 3 Clay 2.5 113 900 0 0.00 6.00 8.50 Layer 4 Sand 2.5 114 0 30 3.00 8.50 11.00 Layer 5 Sand 7.5 114 0 31 3.12 11.00 18.50 Layer 6 Sand 1.00 18.50 18.50 Layer 7 Sand 1.00 18.50 18.50 Layer 8 Clay 0.00 18.50 18.50 Layer 9 Sand 1.00 18.50 18.50 Layer 10 Clay 0.00 18.50 18.50 GPD Caisson Analysis-V1.00 :I: - Mobile-* • `__ 19807 NORTH CREEK PKVYY • BOTLIBLL,WA 98011 • Erin: • .mobile • OFFICE(425)398-7600 - � PROJECT CONSULTANTS: dh.P F GREENWAY �2 POW�E FL RIVER ,� ti' DEVELOPMENT $LLC 12394 SW SCHOLLS FERRY RD �/�� C1c� �0/� PLANBPREPAREDBY:_ _ TIGARD, OR 97223 X04,5 C°""�'T°"i WASHINGTON COUNTY �is�ti 10928 WOODINVILLEREDMOND RD NE.SURE 210 WOODINVILLE,WA 98012 P003932D PHONE 425.487.1732 FAA:425.487.1734 EMAIL cei89comarstorow8x.arn WW W.CORNERSTONE-ENGR.COY - LATITUDE 45° 26' 35.4" N LONGITUDE 122° 48' 11.4" W PROPRIETARY INFORMATION _PROJECT INFO:P003932D THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO T-MOBILE GREENWAY WIRELESS,LLC.SERVICES IS STRICTLY PROHIBITED. 12394 SW SCHOLLS FERRY RD. VICINITY MAP GENERAL LOCATION MAP PROJECT TEAM DRAWING INDEX TIGARD,OR 97223 I 'I vraw A�Ya .- ` ..,TI, I 1 �' APPLICANT: PROGRAM MANAGER DWG DESCRIPTION WASHINGTON COUNTY 9 I' at. s i8- vi (4L�o t` kl'`� FISSUEDFOR: I I I I —y 1 I L .. ! 1 ' } `tea,� T-MOBILE POWDER RIVER DEVELOPMENT T-1 TITLE SHEET•C + B960 NE ALDERWOOD RD PATRICK EWING II s ' p I r �._�_- ) r j ! A•1 ENLARGED SITE PLAN&CONSTRUCTION DETAILS L CONSTRUCTION -,�,.+v°� t , ,. 1'I PORTLAND,OR 97220 (703)626-1188 ., 1 . . A-2 EXISTING&PROPOSED ANTENNA PLAN .'��L ;-4;we a .�p J N CONSULTING ENGINEER CONSTRUCTION PROJECT MANAGER: A-2.1 EXISTING&PROPOSED WEST ELEVATION _REV::DATE:—ISSUED FOR BY:- M t , 1 1 >> I CORNERSTONE ENGINEERING,INC. POWDER RIVER DEVELOPMENT RF-1 RE&COAX DETAILS I —�T1�` t 2-"" t --„,(<1.--,:f.:7▪- 1 44' 16928 WOODINVILLE REDMOND ROAD NE,SUITE 210 JASON CAPONETTE•I --- 1 1 — 1:-±_1,444'. WOODINVILLE,WA 98072 (503)209.4140 • rf!4 Wv5 -j�'+-9r.. _ I r1i 4,---1 ' 'a i 1 -oa I _.... .,-E.- _ MARK W OLSON,P.E. SITE LopolON -- p — - SITE ACQUISITION: ri- I , 41 I --/-... ▪ .. ; ! PH:(425)487-1732 t r 1 ''�" FAX:(425)487-1734 POWDER RIVER DEVELOPMENT +` L ' ��1 B 1 L1 yr. MARY LOU FROSCH A 02-25-13 REDS CHANGE KIO L `_ •c4*s. 4 R" t x PROJECT CONSULTANT: (503)250.4839 I I �` _ a '_) J; J'••• 8.35 POWDER RIVER DEVELOPMENT SERVICES,LLC Qp 06 2612 CONSTRICTION JRF fi- - - - _ f '-•':-.--.T3 .'5.1 -"r .. 1 . i�ae l F,Af 219 S WOODDALE AVENUE ZONING/LAND USE: �` 1 r ' i , a * ,i q I ' �_, EAGLE,ID 83616 POWDER RIVER DEVELOPMENT I W Z 1 4 J ) ,,T.:: PH:(208)938 8844 STEVEN W.TOPP,AICP A 08-19-12 CLIENT REVIEW KIO ' A ( .in t -S� 4 _ (503)708-7337 gf 1.' °^. t 0 F ,, ' ''+.. a I PROPERTY OWNER: —DRAWN BY:—CHK: APV: I1I 0.." i , :" 1 _ i v '+ 'P 1!W '' ' pa* ' b • - WILLIAM G&DIXIE L DAVIDSON RF ENGINEER 'Z 3 ! 1. j 44443:. 1 �� 8915 SW COMMERCIAL ST T-MOBILE I00 I BMH I MWO I I . F' ) - , -:_a- t I TIp.n%• a TIGARD,OR 97223 RATAN JAICHANDRAN CURRENT ISSUE DATE: .:a3:.bm 3- - -.-_ ?ILM o:.,1 "I .- . e� 4 >t, .t. (425)770-0006 02-25-13 • . . . .. - . _LICENSURE: LEGAL DESCRIPTION DRIVING DIRECTIONS .00 F' `p`g �tp INEE. NO TITLE REPORT PROVIDED FROM T-MOBILE PORTLAND OFFICE: q� 745 ii DEPART ON NE ALDERWOOD RD(EAST PROJECT INFORMATION ' ROAD NAME CHANGES TO NE CLARK ST PROJECT INFORMATION THIS IS UNSTAFFED AND RESTRICTED EQUIPMENT AND MUSE % lit ,6 RIGHT ONTO NE HOLMAN ST USED FOR THE TRANSMISSION OF RADIO SIGNALS FOR THE '9 O ROAD NAME CHANGES TO NE 105TH AVE CODE INFORMATION: MAP TAX LOT: PURPOSE OF PROVIDING PUBLIC CELLULAR SERVICE.T-MOBILE Rir W. OV" oattott,t TURN RIGHT ONTO US-30 BYP(NE SANDY BLVD) ZONING CLASSIFICATION:GENERAL COMMERCIAL 1S134BC00900 CERTIFIES THAT THIS TELEPHONE EQUIPMENT FACILITY WILL BE EXPIRATION DATE 12131714 BEAR RIGHT ONTO US-30 BYP(NE KIWNGSWORTH ST) BUILDING CODE:IBC 2009 SERVICED ONLY BY T-MOBILE EMPLOYEES AND THE WORK TAKE RAMP(LEFT)ONTO 1-205(VETERANS MEMORIAL HWY) CONSTRUCTION TYPE:II B NON COMBUSTIBLE AREA OF PARCEL: ASSOCIATED WITH ANY EQUIPMENT CANNOT BE PERFORMED BY —DRAWING INFORMATION: • APPROVALISIGN OFF OF DRAWINGS ni2TOP(RIGHT)ONTO-84(US�O) RNLEFro NTw JURISDICTION:CITY OFTIGARD 21.344 SQ.FT.(0.4BACRES) HANDICAPPED PERSONS.THIS FORRE WILL BE PURPOSES.FREQUENTED ONLY BYSERVICE PERSONNEL FORREPAIRPURP03ES.PURSUANT Do NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY TAKE RAMP(LEFT)ONTO 1-5 PROPOSED BUILDING USE:TELECOMM TO THE AMERICANS WITH DISABILITIES ACT(ADA),APPENDIX B ERRORS ANDSIIONSS oOa�AL PREVIOUS�L AN C ANY - CONSULTANT GROUP SIGN OFF DATE INITIAL AND PRINT NAME SECTION 4.11.(5)(B),THIS FACILITY IS EXEMPT FROM THAT ACT. RRORS A ARE OMISSIONS. SUPERSEDED AL el'THE SS RB OF THIS AT EXIT 294,TAKE RAMP ONTO SR-99W(SW BARBUR BLVD) GENERAL INFORMATION: THE INFORMATION CONTAINED I3 THIS SET OF DOCUMENTS OPERATIONS TAKE RAMP(RIGHT)ONTO SR-217(BEAVERTON-TIGARD HWY) 1.PARKING REQUIREMENTS ARE UNCHANGED.(NON ASSIGNED TECH PARKING) NO POTABLE WATER SUPPLY TO BE PROVIDED AT THIS LOCATION IS PROPRETARY BY NATURE.ANY USE OR DISCLOSURE AT EXIT 4,TURN RIGHT ONTO RAMP 2.TRAFFIC IS UNAFFECTED. OTHER THAN WHICH IS RELATED TO NAMED CLIENT E DEVELOPMENT MANAGER TURN LEFTONTO SR-210(SW SCHOLLS FERRY RD) 3.NO SIGNAGE IS PROPOSED. NO WASTE WATER OR SOLID WASTE WILL BE GENERATED AT THIS STRICTLY PROHIBITED, CONSTRUCTION MANAGER DRIVING DISTANCE: 21.1 MILES LOCATION. DRAWING TITLE: PROJECT MANAGER PR e T i "I° I s N A, AVERA E MAINTENANCE CREW(ONE PERSON)ONE WILL MAKE P. TITLE SHEET AVERAGE OF ONE TRIP PER MONTH AT ONE HOUR PER TRIP. SITE ACQUISITION THIS PROPOSAL IS FOR THE MODIFICATION OF AN EXISTING UNMANNED DRAWING NUMBER: TELECOMMUNICATIONS FACILITY,CONSISTING OF THE REMOVAUREPLACEMENT OF(6) CALL TWO WORKING DAVE BEFORE YOU pot ZONING EXISTING PANEL ANTENNAS WITH(8)NEW TMBXX-0518-R2M PANEL ANTENNAS&THE ADDITION RF ENGINEER OF(4)STACKED B'-0'HIGH 28'0 ANTENNA SHOURDS,THE REMOVAL/REPLACEMENT OF(3) 811 TMA'S WITH(6)NEW TWIN TMA'S;THE ADDITION OF(3)FXFB UNITS&(3)FRIG UNITS INSTALLED NATIONAL UTLITES UNDERGROUND LOCATE T...1 1 REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO IN PROPOSED EQUIPMENT CABINET LOCATED IN BUILDING. .G : WM 1......110%Swat.sINRIND ZO., EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED ^�^IECM '� [CEI JOB NUMBER 12-06299 , • STRUT MOUNTING, T • Mobile"® ANDREW DIPLEXER, TYP(�TOP&BOT STACKED(TYP OF 3 PLCS) (LENGTH TO SUIT) 19107 NORTH CUM(PKWY •• BOTtffil,WA 91011 3/8'0 GALV LAG OPFICE(421)396-7600 SCREW a 24'O.C. (TYP OF EA STRUT) �; i���, PROJECT CONSULTANTS: • a EA WATERTIGHT �EA PENETRATION _ POWDER RIVER • ■'4i=_ DVELOPEMT CERVICES.LLC LANSP REPARED BY: 1/4"0 GALV BOLT(TYP) �� LT•OIVB_ 18828 WOODINVILLE-REDMOND RD NE.SUITE 210 (E)SHELTER WALL(V.I.F.) WOODINVILLE,WA D6072 PHONE:426.467.1732 FAX 425.467.1734 EMAIL ml®wm■lons4Mgr.mm W W W.CORNERSTONEENGRCOM =PROJECT INFO: NOT USED 12 NOT USED 1 i NOT USED 10 DIPLEXER MOUNTING 9 P003932D 22x34 SCALE:NTS 111x17 SCALE:NTS _22x34 SCALE:NTS 111x17 SCALE:NTS 22x34 SCALE:NTS 111x17 SCALE:NTS _22x34 SCALE:11/2"=1'-0" 111x17 SCALE:3/4"=1'-0" 1 NOTES: GREENWAY 1. CONTRACTOR TO PROVIDE ALL HANGERS&HARDWARE (STAINLESS STEEL&/OR GALVANIZED ONLY)TO SUPPORT 12394 SW SCHOLLS FERRY RD. CABLES&JUMPERS EVERY 3'-0". TIGARD,OR 97223 WASHINGTON COUNTY 2. RETURN USED LNA'S&MCPA'S TO T-MOBILE WAREHOUSE. ISSUED FOR: 3. PROPOSED 100AMP BREAKER IN VALARE POWER SHELF W/(2)S2 THHN STRANDED IN EMT OR LT FLEX FROM BREAKER TO COVP. CONSTRUCTION 4. CONTRACTOR TO REMOVE EXISTING RET HOME RUN COAX AND REV::DATE:-ISSUED FOR BY: UNUSED GPS ANTENNA WITH CABLE. - 5. THE FRIG RRU IS TO ONLY BE MOUNTED VERTICALLY. 8. THE COVP IS TO ONLY BE MOUNTED VERTICALLY. }I I I I I I I I I I I I f I l I I 1 1 1 f t I l 1 1 I l l l 11 1(III± 7_ CONTRACTOR TO CONFIRM FINAL LOCATION OF BASE/BOTTOM Q 02-25-13 RFDS CHANGE KIO PROPOSED STACKED DIPLEXERS - MOUNTED TO WALL WI STRUT WITHIN - OF COVP&EXCESS FIBER BOX AT/NEAR OR ON FCOA CABINET THE MEZZANINE FLOOR(TYP OF 3 PLCS) -� _ L(E)LOWER ROOF _ OR ADJACENT ICE BRIDGE POST. Qp 08-28-12 CONSTRUCTION JRF PROPOSED 28"0 REPLACEMENT ANTEN NA SHROUDS,TYP - Q 08-19-12 CLIENT REVIEW KIO --= __- --i.------- -LT — - , 1 ,1 a C DRAWN BY:=CHK.: APV.: PROPOSED REPLACEMENT (E)FCOA CABINET KIO I BMH I MWO ANTENNA TMBXX-6516-R2M(TYP) f-(E)CABLE TRAY(TYP) ■ ' (E)NOKIA ULTRA-SITE CABINET [LICENSURE.CURRENT ISSUE DATE: nu 02-25-13 x :::: 1 ��f PROPOSED TMA,BELOW \91 IN % (3 PER SECTOR,TOTAL OF 8) (E)7/8"0 COAX CABLE (TYP OF 24) 70.18FEA 4)MEZZANINE FLOOR 7 (E)8"CMU WALL,TYP • - I / o�c�� 2 kJ/ / IRATION CI 1y31/14 1 " L(E)WORKSHOP AREA 7 I 1 I I 4E)WORKSHOP AREA/7 –DRAWING INFORMATION: . / / DA ALL Df NLE ORA NDAD.ADVISE CO NCT CONSULTANTS O ANY r / ALL DIAENSNNJS AND ADVISE CONSULTAMS�ANY ERRORS AND OTAISSIONS.ALL PREVIOUS ISSUES OF TH49 DRAWNG ARE SUPERSEDED BY THE LATEST REVISION. - ■ _- _ _ - ■.__ ___ _,.{= THE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS _ IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS ANTENNA \-(E)ROLL-UP GARAGE STR C1LY PROHIBITED. DOOR OPENING DRAWING TITLE: ENLARGED SITE PLAN& CONSTRUCTION DETAILS 1 i 1 DRAWING NUMBER: J PLAN NORTH A-1 1 ENLARGED SITE PLAN 1 ca JOB NUMBER: 12-06299 22x34 SCALE:1/8'=1'-0" 111x17 SCALE:1/16"=1'-0" T • Mobile•® 1980T NORTH CREEK PKWY • . - DOTIiEU.,MA 98011 OFFICE(423)398.7600 - [PROJECT CONSULTANTS: PROPOSED REPLACEMENT ANTENNA TMBXX-0518-R2M TO REPLACE(E) (E)PANEL ANTENNA TO BE - ANTENNA(ALPHA SECTOR;350'AZIMUTH) REMOVED/REPLACED - PowoR¢�vL Fe (ALPHA SECTOR;350'AZIMUTH) _ - _PLANS PREPARED BY PROPOSED TWIN AWS TMA - (1 PER SECTOR,TOTAL OF 3) -, (8 TOTAL 3 TO BE QREMOVEDIREPALCED)- (E)20"0 ANTENNA SHROUD �e"oowr,+sronle 1 _ ��TO BE REMOVED/REPLACED 16028 WOODINVILI��2EDMOND RD NE,SURE 210 +� ,, ,� PHONE:425.487.1M FAX X7.1734 i,. PROPOSED REPLACEMENT EMAIL a soma afnnea q.mm ANTENNA TMBXX-8518-R2M TO �, (E)PANEL ANTENNA TO BE N REPLACE(E)ANTENNA ■ REMOVED/REPLACED (E)PANEL ANTENNA TO BE =PROJECT INFO: PROPOSED REPLACEMENT ANTENNA (GAMMA SECTOR;230°AZIMUTH) TMBXX 6516-R2M TO REPLACE(E) (GAMMA SECTOR;230'AZIMUTH) REMOVED/REPLACED ANTENNA(BETA SECTOR 110'AZIMUTH) (BETA SECTOR;110'AZIMUTH) P003932D PROPOSED(2)8'-0"HIGH 28"0 - - - GREENWAY ANTENNA SHROUDS(STACKED) - - (E)144'-0"HIGH MONOPOLE LI (E)8'CMU WALL.TYP 12394 TSW IGARD.OR 9F7223 Y RD. WASHINGTON COUNTY (E)EDGE OF BUILDING ti•----............ _ (E)EDGE OF BUILDING- ` _ r-ISSUED FOR: I '�� �� L CONSTRUCTION J (E)EDGE OF (E)EDGE OF = -REV::DATE:-ISSUED FOR: BY:- ROOF OVERHANG�_' ROOF OVERHANG- = c - - Q 02-25-13 REDS CHANGE KI0 C I(E)8"CMU WALL.TYP Q 08-2612 CONSTRUCTION JRF qQ 0112 CLIENT REVIEW PROPOSED REPLACEMENT ANTENNA -TMBXX-0518-R2M TO REPLACE(E) (E}PANEL ANTNA TO BE -DRAWN BY:�CHK: APV.: ANTENNA(ALPHA SECTOR;350'AZIMUTH) - REMOVED/REPLACED - L KI0 BMH MWO (ALPHA SECTOR;350'AZIMUTH) - I I PROPOSED TWIN PCS TIM - - CURRENT ISSUE DATE: (1 PER SECTOR,TOTAL OF 3) (E)TWIN AWS TMA Q (1 PER SECTOR (E)20"0 ANTENNA SHROUD 02-25-13 1 . TOTAL OF 3) I TO BE REMOVED/REPLACED LLICENSURE �1T1� �•1 .2, 4g'�"ENO I NEf,P IF PROPOSED REPLACEMENT , �. '..\ �'' 74008PE �• ANTENNA TMBXX-6516-R2M TO (E)PANEL ANTENNA TO BE , REPLACE(E)ANTENNA ��__-_ REMOVED/REPLACED - (E)PANEL ANTENNA TO BE —PROPOSED REPLACEMENT ANTENNA (GAMMA SECTOR;230°AZIMUTH REMOVED/REPLACED (GAMMA SECTOR;230°AZIMUTH) TMBXX 6516 R2M TO REPLACE(E) ( ) (BETA SECTOR;110°AZIMUTH) O� ANTENNA(BETA SECTOR;110°AZIMUTH) - Rff Iy p�� PROPOSED(2)8%0"HIGH 28"0 _ DRAWING INFORMATION: ' ANTENNA SHROUDS(STACKED) - Q (E) HIGH MONOPOLE - 1 — DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY [ERRORS AND OMISSIONS ALL PREVIOUS ISSUES OF THIS - DRAWING ARE SUPERSEDED BY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS BET OF DOCUMENTS • - IS PROPRETARY BY NATURE.ANY USE OR DISCLOSURE _ OTHER THAN WHICH IS RELATED TO NAMED CLIENT N STRICTLY PROHIBITED. 7. DRAWING TITLE: 7. EXISTING&PROPOSED ANTENNA PLAN DRAWING NUMBER PLAN NORTH A 2 1 PROPOSED ANTENNA PLAN 3 EXISTING ANTENNA PLAN 1_0 - CEI JOB NUMBER: 12-06299 22x34 SCALE:112'=1'-0" 111x17 SCALE:114'=1'-C 22x34 SCALE:112'=1'-0" 111517 SCALE:114"=1'..0" T • •Mobile•° I9BO7 NORTHCRElXX PKWY • BOTHELL,WA 98011 OFFICE(425)39B-7600 rPROJECT CONSULTANTS:-44% • L POW CAER RIVER Q4lLOPMENT fiNVIcxl Lit PLANS PREPARED BY: 41111411 COoM EPIiT�ON? Inn WOODINVILLE-REDMOND RD NE,SUITE 210 WOODINVILLE,WA 88072 PHONE:425.487.1792 FAX 425487.1734 EMAIL: celacomerebrearyr.mm W WW.CORNERSTONE-ENGRCAM _PROJECT INFO: P003932D GREENWAY TOP OF(E)ANTENNA SHROUD TOP OF(E)ANTENNA SHROUD 12394 SW SCROLLS FERRY RD. TIGARD,OR 97223 IVEL 44'-0'AGL �r EL 44'-0'AGL l� (E)PANEL ANTENNA TO BE REMOVED/REPLACED WASHINGTON COUNTY RAD CENTER OF PROPOSED J� PROPOSED REPLACEMENT ANTENNA (2 PER SECTOR TOTAL OF 8) PANEL ANTENNAS _ TMBXX-6516-R2M TO REPLACE(E) RAD CENTER OF(E)T-MOBILE ANTENNA ARRAY a ( [ISSUED FOR: �,-0„ ANTENNA(2 PER SECTOR TOTAL OF 6) 0"AGL m I Q (E)TWIN AWE TMA TO BE (E)TWIN AWS TMA CONSTRUCTION J;r REMOVE0IREPLACED V�(1 PER SECTOR TOTAL OF 3) 1 PROPOSED TWIN AWS TNA II PROPOSED TWIN PCS TMA (1 PER SECTOR TOTAL OF 3)— II � TE:=ISSUED FOR: BY:_. Q (1 PER SECTOR,TOTAL OF 3)— — (1 PER SECTOR,TOTAL OF 3) ( Q Q (1 PER SECTOR,R,T I (1 PER SECTOR,TOTAL OF 3) (I I (E)TWIN PCS TMA II (E)TWIN AWS TMA II I (1 PER SECTOR,TOTAL OF 3) :I II (1 PER SECTOR TOTAL OF 3) TO BE REMOVED/REPLACED II § I TO BE REMOVED/REPLACED �+� II I :I II PROPOSED(2)8'-0"HIGH 28'0 BOTTOM OF(E)ANTENNA SHROUD I; BOTTOM OF(E)ANTENNA SHROUD �EL 28'-0'AGL ANTENNA SHROUDS(STACKED) �Q�� `� /ti (E)18"0 MONOPOLE 1 02-25 13 RFDS CHANGE 100 �� (E)18"0 MONOPOLE 1 / \�� QPROPOSED(2)8'-0"HIGH 28"0 Q 06-26-12 CONSTRUCTION JRF 1 ANTENNA SHROUDS(STACKED) —. Qq 06-19-12 CLIENT REVIEW KIO • ` - DRAWN BY:=CHK: APV.• (E)GPS ANTENNA ` - (E)GPS ANTENNA [L _ K9 1 BMH I MWO • ° CURRENT ISSUE DATE:. - -• • • jr . . . 02-25-13 WORKSHOP GARAGE (E)WORKSHOP GARAGE — [LICENSURE: (E7 • • i�y� 74 001,44 f a 53: ��� R�We O • a`(i; . - . ..•RATION DATE 12/31/14 Alk GRADE(REF) GRADE(REF) • EL 0'-0"(ASSUMED) EL O'-0'(ASSUMED) —DRAWING INFORMATION: DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS MID OMISSIONS.ALL PREVIOUS ISSUES OF THIS • DRAWING ARE SUPERSEDED SY THE LATEST REVISION. THE INFORMATION CONTAINED IN THIS BET OF DOCUMENTS IS PROPWETARY BY NATURE.ANY USE CR DISCLOSURE OTHER THAN WHICH IS RELATED TO NAMED CLIENT IS STRICTLY PROHIBITED. DRAWING TITLE: EXISTING AND PROPOSED 4 WEST ELEVATION DRAWING NUMBER: PLAN NORTH A-2. 1 1 PROPOSED WEST ELEVATION 2 EXISTING WEST ELEVATION A 0 CEI JOB NUMBER: 12-05299 22x34 SCALE:3/16'-1'-0' 111217 SCALE:3/32'=1"-0" _ 22x34 SCALE:3/16"=1'-0' 111x17 SCALE:3/32'=1'-0' _ A .--____---- - -- ----------- - --- --- ----- -. — A PKWY Existing Configuration •T • •Mobile•° BOT T�LL,IVA 9PIn I _--.---.___--__—_ .—_._._-- .._.. ------------ _ -- ._.--_.1_...____ OFFICE(425)39&7600 Propoexd GSM,UMTS Configuration P0000320 PROJECT CONSULTANTS: P'OW DER RIVER ■ COAXIAL CABLE NOTES: A(d1B BI" GOMIS Wm Ws Gamma DEVELOPMENT Nia CBB.tic UMTI 1. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHERPROOFED. yMq wu LM I 1 WTI 11 WPM I (MI 1) PLANS PREPARED BY: 2. CONTRACTOR TO PROVIDE DRIP LOOPS IN CABLES AND JUMPERS WHERE `• con,4enTOn,e NECESSARY. SI >( R 10926 WOCO1NVCLE REDMOND RD NE,SUITE 210 3. TAGGING: '` "•` WOODEN]UE,WA IM072 3.1 ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE \ - PHONE:425,407.1732 FAX 425A67.1734 — TO INDICATE THE ANTENNA SECTOR. EMAIL DN®ownw.trr«ymn 3.2 COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE CONNECTORS + +Ill: WNfW.COIIiERSTONE�NORCOM AND EACH END OF JUMPERS AS CLOSE TO EACH END AS .PROJECT INFO: POSSIBLE.(NOT TO INTERFERE WITH WEATHERPROOFING). STEP 1 P003932D 4. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3'-0• ON CENTER.CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO 1 2 1 2 1 2 1 2 1 2 1 2 GREENWAY MEET THIS REQUIREMENT. 12394 SW SCHOLLS FERRY RD. Proposed COn i TIGARD,OR 97223 - 1��Uf8tiOn _ WASHINGTON COUNTY MIN-C•MApUNNIN.3A I -ISSUED FOR: 6,.....1 I16pha•d Y 2 Clued CONSTRUCTION J 0. _REV::DATE:—ISSUED FOR: BY:— XIS-'P�/i� /,�� /� v ���!// n� ����_ Qj 02-25-13 RFDS CHANGE KK)J roe. ELECTRICAL TAPE — L pQ 06-28-12 CONSTRUCTION JRF BUTYL TAPE(ALSO KNOWN .. . (1 LAYER)— AS MASTIC,TAFFY TAPE) _ 1x• lr STEP 2 STEP 3 5.v. — —DRAWN BY:—CHK: APV.: ... [ IGO I BMH I MWO 1 I [LICENSURE CURRENT ISSUE DATE 02-25-13 : NOTE: MINK t''� `,. 4' 4• VERTICAL CONNECTIONS SHALL BE •1 '�- ! gC I N �9� TAPED FROM THE BOTTOM UP SO }� '- ~ 458PE �'■, OVERLAP MOVES WATER AWAY FROM L ..— M. CONNECTON,TYP. S A PROVIDE HEAT SHRINK IN PLACE OF 111114111 C. ...7-.. / I "='---_F TAPE FOR QUAD POLES AND LNA's(TYP.) R/f0 - INA f�tJ �----- _ _ ' 111 i -r E70 1TgN M4 1 I ELECTRICAL TAPE 3 LAYERS WITH T TAPE AND 3 DRAWING INFORMATION: LAYERS IN we TAPE(ALL WITH MINIMUM 50% V DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY OVERLAP).ALL TAPE ENDS SHALL BE CUT(DO NOT ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY COAT WITH 3M SCOTCH COTE SPRAY SEALER ERRORS AND OMISSIONS.ALL PREVOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. 111/• STEP 4 TIE INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE MI OTHER THAN WHICH IS RELATED TO MANED CLIENT B STRICTLY PROHBITED. FDRAVVING TITLE: Site_ID -P003932D,Version -1,Design Status-APPROVED RF&COAX DETAILS LDRAVVING NUMBER: RF-1 1 COAXIAL CABLE WEATHERPROOFING 2 RF DETAILS i• CEI JOB NUMBER: 12-06299 22x34 SCALE:NTS 111x17 SCALE:NTS 22x34 SCALE:NTS 111x17 SCALE:NTS