Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
RECEIVED OCT 8 2014 SITE PLAN CITYOFWD BUILDING DIVISION PT Ac. • un; 1 heeCTer. /lot) rc,v. T 11 TI,�e a� a nv� SIT%,1 o n U n ST I J i �1 CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved: [y� PL OTC: [ Permit#: bt(eG20( --00 PL ca_ 0j Address: (A, re 1 v 5 'L I r - E- I F=1G Suite#• By: Date: 344 • OFFICE COPY ofF.c--e PL STREET S E NOTE - Please show the following on the site plan: • Location of Indoor Unit and Outdoor Unit Indicate how the flue will be run (thru the roof- out the sidewall-etc) ! • Indicate with dotted line how the lineset will be run and approx. distance • Indicate how the condensate will be run 7500 SW Tech Center Drive Speciatty Suite#130 Tigard,OR. 97223 HEATING&COOLING INC. (503)620-5643 Fax:(503)681-0793 www.specialitvheatins.com lw...1101 comfor!nblr until you we! REGEIVED i� COMFORT COM OCT s 2014 oi- 3 UNMATCHED EXPERTISE gU'CIITYOF WAD Search 4 Home I Ways'l� IEISPINns I About Us I My Account I Customer Service Home » Central and Ductless Forced Air » Unit Heaters » ... » Gravity Vented Gas Unit Heaters - F-125 Gas Fired Unit Heater - Gravity Vented - NG - Aluminized Heat Exchanger - 125,000 BTU Add a review Your Price: S1.214.10 Free Ground Shipping(details) •� F-125 rniReznor 1 ..... "--' Ships out within 2-3 weeks. '` s r" -'rrrr''' [ P Ac«matnen 3123" PayPal 1 (/i 3o s .r�on 1 rlOrf MrilM[SS pay+YPfiS rewsrtro J�•r •-•1^ 0" fwrr.+d.. i Reznor F-125 Gas Fired Unit Heater,Gravity vent,80%efficiency.NG,Aluminized Heat Exchanger-125,000 BTU.115V,80%efficiency,1600 CFM :.. rn.m: --.. Product Overview REZNOR Reznor F-125 Gas Fired Unit Heater,Gravity Vented, NG,Aluminized Heat Exchanger-125.000 BTU Reznor F-125 Gas Fired Unit Heater is a 115 volt,gas fired unit heater.It provides a 125000 BTU/hr.output with an 80%thermal efficiency.F models come equipped with blocked vent shut Product Specifications off.Reznor F-125 is designed for ceiling suspension.Gas-fired appliances are not designed for General Data use in atmospheres containing flammable vapors,combustible dust,or chlorinated or halogenated hydrocarbons.In California,F model units require AH2 or AH3 spark pilot. Product Line F Heat Exchanger Material Aluminized Steel Reznor F-125 Gas Fired Unit Heater Features: Fuel Source Natural Gas • Aluminized steel heat exchanger Vent Type Chimney Orientation Vertical • Single stage combination gas valve Performance Data • Transformer for 24-volt controls Heating Capacity(BTU) 100.000 • Manual match-lit pilot with 100%lockout Maximum Input Capacity(BTU) 125.000 • Blocked vent shutoff system Efficiency(%) 80 • 2-pt threaded hanger connections Minimum Air Flow(CFM) 1 • Convenient bottom burner access Maximum Air Flow(CFM) 1 Electrical Data Reznor F-125 Gas Fired Unit Heater Warranty: Voltage(Volts) 115 • 1 year parts warranty Phase 1 Frequency(Hertz) 60 Product Manuals Dimensions r�rI� Flue Connection Size(Inches) 7 Reznor F-125 Catalog Gas Connection Size(Inches) 1/2 Product Height(Inches) 32 Reznor F-125 Submittal Product Width(Inches) 23 3/4 V] Reznor F-125 Parts Manual Product Depth(Inches) 30 1/2 Product Weight(Pounds) 127 Reznor F-125 Installation Manual Warranty VI Reznor F-125 Full Amp Load Table Parts Warranty(Years) 1 trl Reznor F-125 Options and Accessories • _ � a I • � • RE CEIVED OCT 8 2014 gownwistoN'�oFt6D M 2CPq— d ©5 AccuSpec V4.3.2a Transaction #: 5024156 JOB TITLE: Sharper Edge Date: 10/08/2014 Approved By: Submittal review and approval required prior to listed unit(s) being released for production and shipment. Unit(s)configured based on information provided. The A Approver is responsible for ensuring the units, options, and accessories meet the job specifications. ‘93DINE AccuSpec V4.3.2a SUBMITTAL SCHEDULE & DATA Gas-Fired Unit Heaters Job Name: Sharper Edge Date: 10/08/2014 Location: Engineer: Submitted by: Bill Bone Architect: Contractor: Unit Tag Model Number HD 75AS0111FBAN _ Quantity of Units 1 Btu/Hr Input 75,000 Btu/Hr Output 60,000 CFM 1160 Altitude 0-2000 Temperature Rise (degrees F) 48 External Static Pressure (E.S.P) 0.00 Total Static Pressure (T.S.P.) 0.00 Gas Type Natural Gas Control Type Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry • Unit Voltage 115/60/1 Control Voltage 24V Motor HP 1/12 Motor RPM 1625 Blower RPM N/A Heat Exchanger Type Aluminized Steel Heat Exchanger/Burner Options & Accessories (See Attached Pages) Remarks ?OOINE AccuSpec V4.3.2a SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Model Description Qty Tag HD 75AS0111FBAN Propeller Unit Heater 1 53143 HD 75AS0111FBAN 1 wig:MINE AccuSpec V4.3.2a HD MODEL NOMENCLATURE 1,2,3 4,5,6 7 8 9,10 1.1,12 13 14 15 16 HD 75 AS 01 11 F B A N 1,2,3 - Product Type HD - Power Vented Propeller Unit 4,5,6 - Furnace Input Rating 75 - 75,000 Btu/hr Input 7 - Heat Exchanger Type A - Aluminized Steel Heat Exchanger and Burner 8 - Pilot Ignition S - Direct Spark Ignition 9,10 - Motor and Drive Code (Power Code) 01 - 115V motor 11,12 -Gas and Valve/Ignition Control Type (Control Code) 11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13 - Fan Guard Type F - Finger Proof Fan Guard 14-Development Sequence B - Current 15 - Future A- For Future Use 16 - Factory Installed Option N - None 'MOD/NE AccuSpec V4.3.2a GENERAL PERFORMANCE DATA c us � o Intertek General Performance Data Model HD 75 At 0' Elevation Btu/Hr. Input 75,000 Btu/Hr. Output 60,000 Entering Airflow (CFM) 1160 Outlet Velocity 769 Air Temp. Rise (°F) 48 Mounting Height (Max Ft.)1 12 Heat Throw (Max. Mtg. Ft.)2 38 Unit Total Power (Amps) 2.5 As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 75,000 Btu/Hr. Output 60,000 Configured Air Temp Rise (°F) 48 Motor Data Horse Power 1/12 RPM 1625 Type P.S.C. Motor Amps at 115V 1.2 Clearances to Combustibles Top and Bottom 1" Vent Connector 4" Access Side 18" Non-Access Side 1" Rear 18" Mounting Mounting brackets are slotted to accommodate joists on 16" or 24" centerlines. 1 At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65°F ambient with a 48°F air temperature rise with the unit mounted at a maximum mounting height of 12 feet. c E OD/NE AccuSpec V4.3.2a DIMENSIONS - UNIT Model HD Dimensions TS.Y BETWEEN 30.IN NOUN TING HOLES MOUNTING MOLES 14 11.BETWEEN Sr.,.MOUNTING HOLES (MODEL SIZES TOO AND TOT ONLY) TVA 311 a I'LONG (YODEL Safi 100 AND E3E ONLY) A MOUNTING I T BRACKET IF--•1I G POWER VENTER 512E 301E AD�U STABLE 1 VENT APE OuvFR6 ` CONNEC TIOM rC� CONNECTION ar III.I l� I��',•.• O • ' GAS ICONNECTION 'OPENING ��loll • 7�� Ji1 Ilil' ` COEE xiN,: M N ACCESS •AN EL ACCESS k LEA PESR yEN Model Size HD75 Dimensions (in inches) A 26.8 B 18 • C 16.5 D 14.9 E 15.9 F 10.7 G 18.5 H 7.8 31 J 25 Vent Connector 3 Diameter Gas Connection 1/2 Diameter Fan Diameter 14 Approx. Shipping 85 lbs. Weight • Standards All unit(s)shall include: C.S.A. (Canadian Standards Association) design certification for use in both the US and Canada to the ANSI Z83.8 - latest revision, standard for "Gas Unit Heater and Gas-Fired Duct Furnaces" for safe operation, construction, and performance Mechanical Configuration Furnace(s) section with 80% minimum efficiency provided by an indirect-fired tubular heat exchanger with individually fired tubes for maximum heat transfer with minimal noise of flame ignition/extinction. Venting Arrangement The venting shall be a power exhausted arrangement. The unit shall be tested to insure proper ignition when the unit is subjected to 40 mile per hour wind velocities. The unit shall also include a factory mounted differential pressure switch designed to prevent main burner ignition until positive venting has been proven. Unit Casing The unit heater(s) casing shall be constructed of not less than 22 gauge aluminized steel with minimization of exposed fasteners. All exterior casing parts shall be cleaned of all oils and a phosphate coating applied prior to painting. The exterior casing parts shall then be painted with an electrostatically applied baked-on gray-green polyester powder paint (7-mil thickness) for corrosion resistance. The unit shall be furnished with horizontal air deflectors. The deflectors are adjustable to provide for horizontal directional airflow control (up or down). Furnace Section The heat exchanger(s) shall be made of 18 gauge aluminized steel tubes and headers. The thermal efficiency of the unit(s) shall be a minimum of 80% efficient for all air flow ranges. Each heat exchanger tube shall be individually and directly flame-fired. The heat exchanger tube shall be crimped to allow for thermal expansion and contraction. The flue collector box shall be made of 20 gauge aluminized steel. The heat exchanger(s) seams and duct connections shall be certified to withstand 0.9" W.C. external static pressure without burner flame disturbance. The burner(s) shall be in-shot type, directly firing each heat exchanger tube individually and is designed for good lighting characteristics without noise of extinction for both natural and propane gas. The ignition controller(s) shall be 100% shut-off with continuous retry. • The gas pressure shall be between 6-7" W.0 for natural gas. The solid state ignition system shall directly light the gas by means of a direct spark igniter each time the system is energized. v • The unit gas controls shall be provided with the following: Single-stage gas controls with a single-stage combination gas control, an ignition control, and a single-stage low voltage thermostat. The unit fires at 100% full fire based on a call for heat from a room thermostat. An automatic reset high limit switch mounted in the air stream to shut off the gas supply in the event of overheating. A time delay relay that delays the start of the air mover to allow the heat exchanger a warm-up period after a call for heat. The time delay relay shall also continue the air mover operation after the thermostat has been satisfied to remove any residual heat in the heat exchanger. The unit shall be orificed for 0-2000 feet elevation above sea level. Electrical All electrical components shall carry UL, ETL, or CSA listing. A low voltage terminal board shall be provided for direct wiring connection to an external thermostat. A single 115V to 24V step down transformer shall be provided for all unit controls. Air Mover The motor horsepower shall be 1/12 H.P. • The motor wiring shall be in flexible metal BX conduit. • The motor shall be controlled by a time delay relay. Propeller models shall meet the following requirements: The motor type shall be Single-Speed, Open Drip Proof (ODP). The air mover motor shall be a 115V motor. Mounting The unit shall be equipped with mounting brackets to allow for threaded rod suspension or to be bolted directly to the ceiling support structure allowing 1" of top clearance. Accessories The following field installed accessory control devices shall be provided with the unit: