Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD MECHANICAL PERMIT COMMUNITY DEVELOPMENT Permit#: MEC2014-00544 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/08/2014 Parcel: 1 S135BA00102 Jurisdiction: Tigard Site address: 10114 SW WASHINGTON SQUARE RD Project: Pieology Subdivision: OAKBURG Lot: 9 Project Description: Installing a new cooler. Contractor: MASTERCRAFT STAINLESS INC Owner: PPR SQUARE TOO LLC 10120 SW 80TH AVE PO BOX 847 PORTLAND, OR 97223 CARLSBAD,CA 92018 PHONE: 503-314-5864 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 10/08/2014 $207.21 Class of Work: ALT Type of Const: VB Plan Review 10/08/2014 $51.80 Occupancy Grp: A-2 Occupancy Load: 12%State Surcharge-Mechanical 10/08/2014 $24.87 Stories: 1 Info Process/Archiving-Sm$0.50(up to 10/08/2014 $5.00 11x17) Project Valuation: $5,000.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $288.88 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Walk in Duct Work: cooler Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Util. otification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the les direct questions to OUNC ling 503.232.1987 or 1.800.332.2344. ssued By: k Permittee Signature: ` Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Application FOR OFFICE USE ONLI City of Tigard Received� ` • �� -) Permit No. �pco/q 005•r7,Y Irri " 13125 SW Hall Blvd.,Tigard,OR 97223 plan Revi l Phone: 503.718.2439 Fax: 503.598.196Cjikt Date/By: ' ( & K.Other Permit: e li O/4-00/-79 TIGARD Inspection Line: 503.639.4175 Date Ready y: tuns See Psge 2 for f Internet: www.tigard-or.gov Notified/Method: Q Supplemental Information 2p1 �• I r_I TYPE OF W 1 'I., - / M 'CIAL FEE* SCHEDULE - USE CHECKLIST L. - Mechanical permit fees*are based on the value of the work ❑New construction ❑Addition/alteration/7. t �n+ �l performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: Mi,� mechanical materials,equipment,Igor,overhead,and profit. Value:$ C=1:: ::, • RESIDENTIAL EQUIPMENT/SkSTEMS FEES* ❑ 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist. ❑ Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address: 1 O ( I ck, G� ) `t G..1-6K., ,.. • gli3 Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: -r(( 7 Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: I Project name: ?kW t.1Zeq Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 �.J Residential boiler(radiator or � hydronic) 23.32 __ p 5 10 Unit heaters(fuel-type,not electric), �.X � 5 0, in-wall,in-duct,suspended,etc. 46.75 tiS j ` Other:event for any of above 23.32 Subdivision: `0`Y�11 Lot no.: Ot 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas A.)•rw.1N.) Cmc>( fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ❑ PROPERTY OWNER I 'D TENANT Other: 23.32 Environmental exhaust and ventilation: Name: •t7t (--)L S<<:,,-- Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 "'APPLICANT I CONTACT PERSON Other: 23.32 Fuel piping: Business name: C J � .( ; Q0-0 $14.15 for first four;$4.03 for each additional Contact name: 1-t:V(i\.) (CA (tO Furnace,etc. Address: 2-'3 11ki LOZ:lf S0(rk.-* ( (0 Gas heat pump Wall/sus tended/unit heater City/State/ZIP: VA A;0/51.)V 11...A (0 1 Water heater Phone:(36;0) 73.7„icy 9 p I Fax::(31/4:0) L1 Q_. c ) t Fireplace Range E-mail: leg-Week( n w `' I )O IFti�.ZDOn 1 Barbecue CONTRACTOR Clothes dryer(gas) Business name: gai3c6T.T ilk.i\CL-cc.Z.9 ,,xj kW Q.,e,p4pr Other: MECHANICAL PERMIT FEES* Address: ` Subtotal �( A/ �(•� City/State/ZIP: prt,b )2 77253 a` y Minimum permit fee($90.00) ,Pell tit Plan review(25%of permit fee) 57.4'° Phone:(5a) 11 -. Fax:( ) 01.1 _ State surcharge(12%of permit fee) ,Z a(_9'7 CCB lic.: 1'730 22-9 -,57 At 19 5 ago i/ '/ /h TOTAL PERMIT FEE $.gg This permit application expires if a permit is not obtained within 180 ' days after it has been accepted as complete. Authorized signature: - ���.��_ * Fee methodology set by Tri-County Building Industry Service Board Print name: g ._.\.)I r3 lclNckl Date: I\Building\Permits\MEC_PermitApp 0401 I3.doc 440-4617T(I 1/02/COM/WEB) r - / 13'-4" 12'-8" I- 1 Fri m rn .Ooze) .00•tr ) .00.917 ) .00.91` ).00ze E A C4 n al 8 co * / (c) 20 < 2 EACH#12 x 1" SHEET METAL SCREW 3/8"x 2-1/2" ANCHOR BOLT 10 GA. SHEET METAL 1,4 C° \/ ANGLE 2"x 2"x 4" `' 39.00 MIN. CLEAR '%�� A FOUNDATION FASTENER AT EVERY PANEL JOINING N N.T.S. M Eft' N Et c4 \ ii 12.001 44.00' ( 46.00' ( 46.00" 200• u u � " PANEL ANCHOR POINT PANEL ANCHOR LAYOUT PIEOLOGY — WASHINGTON SQUARE s I WALK-IN SPECIFICATIONS -NN\\\\ REEvEc in • i el ce O 3'. CC !a( o 0 PANELS 2--7- OCT 2 2014 a1, a o FOAMED IN PLACE URETHANE FOAM 4" . EXTERIOR FINISH ` T GAQ�} �O/ E' 0 .T re L J CITYOF 1 IGA ILA i E Z ~- w WALL:GALVALUME-EMBOSSED 26 GA ��IEy�.,�.A 1_+1'J Y�7�01') < M 0 CI TOP:GALVALUME-EMBOSSED 26 GA IL�IIAi'l�IwlYYfflllr���� ``J 0 re INTERIOR FINISH 0 WALL:GALVALUME-EMBOSSED 26 GA TOP:GALVALUME-EMBOSSED 26 GA H I- FLOOR TYPE 4,5„ W COl COOLER:FLAT BOTTOM WALLS Y. ee WALK-IN ACCESSORIES cE (1)OREGON SEAL OF APPROVAL (6)TIE DOWN ANGLE-1-1/2 X 1-1/2 X 96"(INT WALL TO CL INCL PARTITIONS) (6)TIE DOWN ANGLE-1-1R"X 6'X 96'(W-IN FL TO FOUNDATION) 0 p' _ (2)LIGHT VAPOR PROOF ASY W (3)TRIM ANGLED 3"X 3"X 8FT GALVALUME EMBOSSED 26 GA (1)PC099T3 IHP INDOOR TOP MOUNT POLAR PAK 208-230/60/1 O 0 (1)1 HP 2-5 YR EXTENDED COMPRESSOR WARRANTY ad (85)COVE BASE,GALVALUME EMBOSSED 26 GA 1.25 X 4.25 W l7 Z a ... W O °s< . O REFRIGERATION �7 W3ao CITY OF TIGARD Cooler R3rWIEWED FOR CODE COMPLIANCE b Approved: [ t 4 O"TC: [ ] rz a I'crmit #: Ma-C-20(4—c Address: (Q[I4 )t } -i m Suitc #: Iu By: 241; Date: i (D f thVl a c. OFFICE COPY LEGEND Ilkit REFERENCE LAYOUT(S)FOR LOCATIONS AND FOR H I IFICATIONS REFER TO (,FNFR AI NOTES 8'-6" 11.50"( a in 0 M Scale Reference N SCALE 1/ 12 a ce 0 0 ?\ATTENTION FOR APPROVAL SPACE DESIGNATED P I.DRAWING NOT INTENDED FOR INSTALIAT10U-DESIGN APPLICATION ONLY. YOU MUST REVIEW ALL NOTES,DETAILS,DIMENSIONS, FOR ENGINEERS SEAL 2.ALL WALK-INS ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE FINISHES,DOORS SIZES,LOCATIONS ANC SWINGS SHEET# I AD-2 of 7 3.PENETRATIONS MID SEXING OF ARE THE RESPONSIBILITY OF OTHERS - - — -- - - - -- --- 1 H.ALLOW L CONTRACTOR REK TO DESIGN AND SOF PER ON MA UAROUNDOOR EPANELFORFA TI SMOOTH FINISH DISCLAIMER 6.GENERAL Y TILE R CONC ET REFER TO DESIAN AND METAL PANEL MANUAL FOR ROOK DETAIL TO STAINING 6.QUARRY TILE OR CONCRETE FLOOR APPLICATIONS:METAL PANEL FACING MAY BE NECESSARY THAT STAINING DUE TO PROPERLY VE MOISTURE SCALE CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS.IT IS ABSOLUTELY NECESSARY TINT EACH ROOM BE PROPERLY VENTILATED. ❑APPROVAL-NO CHANGE REQUIRED,MANUFACTURE AS PLANT LOC. SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO EFFECTS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS °R'"N" ...".. o... c".<.�. 7.PANEL LAYOUT WAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS ' Panels with non-textured and/or no-profile panel finishes(smooth finishes)on the 8,WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE ❑APPROVED AS NOTED-MAKE REQUIRED CHANGES AND exterior and interior faces may exhibit"oil canning"and flatness imperfections on the • 9.IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 24'OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES MANUFACTURE AS DRAWN. 10.FLOOR,CURB,MID PIT DETAILS ARE HAl GENERAL REFERENCE ONLY.THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE surface. Our standard panels have a stucco embossed texture on both faces that helps to DESIGN OR PREPARATION OF THE INSULATED RWR,SUB-SLAB OR CURBS,WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED El NOT APPROVED-DESIGN CHANGES REQUIRE DRAWING reduce oil canning and any other irregularities in the exposed surface. Please be aware ING ENGINEER.ALL FOOTINGS,FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR REVISION AND RESUBMISSION. OR CODE IL.TTHENFOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS:FLAME SPREAD RATING 20,SMOKE of this potential situation in your specification process. Such"oil canning'and flatness DEVELOPED RATING:450;FLASH IGNITHIN TEMPERATURE RATING 91ST SPONTANEOUS IGNITION TEMPERATURE RATING 9509. DATE: BY: issues are typical and are not covered under standard warranties. .15 I + F iJ AL.IIIY/ 4 Cbc.0 AMIIMMI °0:, 111MIIIIMIll +00. )J o, \z, m (3), \ Ri m 02 rn X r W X ,O r C kg OD�ODD No. DATE BY DESCRIPTION " "'� N 4 o --1-Is r � MID _ PREFERRED MARKETIN " Kolpak p GROUP C 4 TIGARD,OR 97223 USA o PIEOLOGY- DRAWING#: m 5 WASHINGTON UNIT#: I V SQUARE,TIGARD, ORDER#: ` ' ,OR ■ COMPARTMENT CONDENSING UNIT TEMP F COMPRESSOR DIMENSIONS COMPRESSOR NDENSER FAN MTR TOTAL MX AMP CONNECTIONS O.D. RCV CAP Lrl DC DESCRIPTION WI QTY MODEL# TYPE L(A) W(B) 1 H(C) LBS HP RLA LRA V HZ FLA V L�. AMPS DISC SUCT UQ @ 90%FULL(Ibs) Y M COMPARTMENT UNIT COOLER CI N TEMP F MODEL# DIMENSIONS FAN HEATER CONNECTIONS O.D. fl' , a ° ;., DESCRIPTION WI QTY (DEFROST: A-AIR E-ELECTRIC) L(D) W(E) H(F) I LBS AMP V AMP V 0 SUCT LQ DRAIN I O ii ii ii Y " - W Z Z in 0 Q 0 CI in .J Z H I- W OC Q F O c W IY Z a C2W J= CC D: 2 D a c9 s21:1 ATTENTION: REFRIGERATION DRAWING IS REFERENCE ONLY.REPRESENTATION MAY NOT BE TO SCALE g AND OR MAY NOT REFLECT INFORMATION SPECIFIED IN CHART ABOVE. E �C ' " r + MO ROEPD E RFFOOATR R IO SERVICING CD W FR OW 4.4•0 —'. 4 sucreyL AND OIL` '�` ,z _ SIDE VIEW e' CONDENSING UNIT ASSEMBLY CLEARANCE REQUIREMENT LEGEND ••AM,EM,&EL COILS MOUNT MIN.IF OFF WALL Cc �■■ -FOR AMB&ELB COILS ru armor ■U MOUNT MIN.24.OFF WALL ...—AIR FLOW ON stme MS.MR VRI Val • f (LOW TEMPERATURE ONLY) r 1 SPERARID ANDIT LINE ONATRR CONNECTION SPIRALED AND TAPED ON DRAIN N01� (IN REAR) LINE BEFORE APPLYING INSULATION TRAP ■REFERENCE LAYOUT(S)FOR CONNECTIONS SUCTION ) LN BY PLUMBING CONTRACTOR. LOCATIONS AND FOR (IN REAR) CONNECTION SPECIFICATIONS REFER TO (IN REAR) ���` GENERAL NOTES. 1"AIR GAP EVAPORATOR-MODEL AM,EM, EL,AMB, ELB DRAIN LINE DETAIL OFF OF WOLL ' UNION VI AIR OW N (LOW TEMPERATURE ONLY) n ELECTRICAL CONNECTION MPT DRAIN ELECTRIC DNAIN LINE HEATER ON / pL� SPIRALED AND TAPED ON DRAIN UNE CONNECTION BY PLUMBING CONTRACTOR. TRAP ce UNE BEFORE APPLYING INSULATION 0 •■■■•■•■■'A d aR D: Q C7 EVAPORATOR-MODEL AMC, EMC, ELC,AML,ELL,TW, MINN DRAIN LINE DETAIL MOUNT MIN.6 OFF OF WALL SHEET I: I AD-7of7 D E ^' . ME�I AIR FLOW I SCALE.. �..�. .� F • UNION PLANT LOC. -- 1 AIR ROW p••.SC E• (lOW TEMPERATURE ONLY) MPT DRAIN ELECTRIC DRAIN UNE HEATER TRAP UQUID CONNECTION(IN REAR) ELECTRICAL CONNECTION SPIRALED AND TAPED ON DRAIN F ' LINE BEFORE APPLYING INSULATION SUCTION CONNECTION(IN REAR) BY PLUMBING CONTRACTOR •i TOyyS I1••61A11.Fro COLOR CODE 1'41RT•• CERTIFIEDTOCANCSA E1Y SID C22.2 NO.236-05 ' M IntM•k EVAPORATOR-MODEL SLA, SLE,ASLA,ASLE,TL DRAIN LINE DETAIL __ REFRIGERATION IIDit0s ONl3 "0H0i i ■ WALK-IN SPECIFICATIONS .0i o Y : a /� i M R ill N fl. A� ' a 0 ir 0i ii ZHYW W M CC et 0 CC 0 Z H I- W IY In W O W ia >6r • o g:W W O o5/ z 0 a. .. tin IA U4 W Ca MINIM MILLI a.... 1=AtA.LEGEND NG REFERENCE UVOUT(5)FOR LOCATIONS AND FOR SPECIFICATIONS REFER TO • Q IA 0 Pt N N N. cn irg 0 d cc Q ATTENTION FOR APPROVAL SPACE DESIGNATED r 1.DRAWN'NOT IREMDEDPONINSTAIIAUW.-DESIGN APPLICATION ONLY. YOU MUST REVIEW " N FOR ENGINEERS SEAL T.AIL WALK-INS ARE DESIGNED FOR INDOOR APPLXATION UNLESS NOTED OTHERWISE .,.,,..... _ . C`, 4. TI M1 ...NI N.,n` IIMEMEM AD-6 of 3.PENETRATIONS AND SEALING OF ARE THE RESPONSIBILITY OF OTHERS —- S.ALLOW R2'O MINIMUM CORCLEARANCE RWITH OAIRFLOWDF5CIF PER ONMAFT AROUND ENTIRE PANEL SURFACES SMOOTH FINISH DISCLAIMER S.GENERAL Y CONTRACTOR R CONCRETE ET REFER APPLICATIONS:AN AND METAL PA EL AC NG AIR SUSC DETAIL TO STAINING 6.CREATE TILE H HYDRATI OF C CRETEMETAL LS.IT FACING LUT BE NE-CESP SUSCEPTIBLE THAT STAINING ROOM TO OP E LY VE VENTILATED.CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS.IT IS ABSOLUTELY NECESSARY THAT EACH R(xM BE PROPERLY VENTIUTED. 0 A►PROVAE-NO CHANGE REQUIRED,MANUFACTURE AS glUnill " SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO ErnLiS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS DRAWN. 9Sffi0® w 7.PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS Panels with non-textured and/or no-profile panel finishes(smooth finishes)on the ___ 8.WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE iJ APPROVED AS NOTED-MAKE REQUIRED CHANGES AND exterior and interior faces may exhibit"oil canning"and flatness imperfections on the 9.IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF N'OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES MANUFACTURE AS DRAWN. ___ • 10.FLOOR,CURB,AND PIT DETAILS ARE FOR GENERAL REFERENCE ONLY.THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE surface. Our standard panels have a stucco embossed texture on both faces that helps to DESIGN OR PREPARATION OF THE INSULATED FLOOR.SUB-SLAB OR CURBS,WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED ❑PNOT AMROVE-DESIGN LUNGES REQUIRE DRAWING reduce oil canning and any other irregularities in the exposed surface. Please be aware ENGINEER.ALL FOOTINGS,FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR REVISION AND RESUBMISSION. COLOR CODE ARCHITECT. " CATTECT_ of this potential situation in your specification process. Sucoil canning"and flatness 11.THE FOAM PLASTIC USED IN THIS PRODUCE COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS:FLAME SPREAD RATING:20;SMOKE DEVELOPED RATING:450;RASH IGNITION TEMPERATURE RATING:9154;SPONTANEOUS IGN TION TEMPERATURE RATING:9504. DATE: BY: issues are typical and are not covered under standard warranties. S I L L g.-6" e 1 e - 7-10" - WALK-IN SPECIFICATIONS In ct CD � : M m C. i} a 00 Q !1' # # ii PANELS FOAMED IN PLACE URETHANE FOAM 4" ; Xi (.9 w et EXTERIOR FINISH ill WALL:GALVALUME-EMBOSSED 26 GA O I. Z C TOP:GALVALUME-EMBOSSED 26 GA r- - ` 3 0 Ce > .0C-).00'61 Lr-------- — 4-9cj.'ci..OS'l ,,6Dc. J ¢ o Tl y '1 ce INTERIOR FINISH l A g +.d WALL:GALVALUME-EMBOSSED 26 GA K^ TO {I-,! Z P:GALVALUME-EMBOSSED 26 GA -I 1- W 53'• 49" toll COOLLER:FLAT BOTTOM WALLS r—,00'Zl 00'6 t� 1 - LS .09'11 00'Zl 1 00'ZOl x 05.44 1'J IY N 30.4" I 36V.." 1 26- - WA -IN ACCESSORIES g UC 4. (1)OREGON SEAL OF APPROVAL .- }0 (6)TIE DOWN ANGLE-1-1/2-X 1-1/2'X 96'CUNT WALL TO CL INC.PARTITIONS) 0 0 (6)TIE DOWN ANGLE-1-1/2"X 6"X96'(W-IN FL TO FOUNDATION) 0 W (2)LIGHT VAPOR PROOF ASY M (3)TRIM ANGLED 3"X 3'X 8FT GALVALUME EMBOSSED 26 GA (1)PC099T3 1HP INDOOR TOP MOUNT POLAR PAK 208-230/60/1 `H h' a. I 0 0 (1)1 HP 2-5 YR EXTENDED COMPRESSOR WARRANTY (85)COVE BASE,GALVALUME EMBOSSED 26 GA 1.25 X 9.25 IW 0 z W ID 1�1d Q O=< ,,ww p=sg REFRIGERATION 00 4 v ''' V 6 3171 o d OOZO1. x009410 O) O O — +1 O (O O "t- z 0 K U Un lL 0 A 0 m OI 0 r o ca o Q 0 00•ZOL x 00'94 10 0 ,z 0) O O O O LEGEND . I IIE1NT A °0 I O1 o 00•ZOL x 09 Z 10 l:- lical co o o I°o REFERENCE LAYOUT(S)FOR C7 I�_ LOCATIONS AND FOR •L J SPECIFICATIONS REFER TO 2.00'; 32.00" i 46.00" (12.00' TOPS LAYOUT I-I N g a —J• VS 12.00' 32.00" ( 46.00" (MOO" _1 M N N WALLS LAYOUT 0 0 0 Dc a GATT E N TI O N FOR APPROVAL SPACE DESIGNATED r YOU MUST REVIEW ALL NOTES,DETAILS,DIMENSIONS, FOR ENGINEERS SEAL 1.ALL WAM-I MOT ARE DESIGNED FOR LMfAWLTIOA-O UNLESS u NOTED OTHERWISE SHEET# I AD-5 of 7 1.ALL W141FIN5 ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE FlNISHES.DOORS SIZES,LOCATIONS AND SWINGS 3.PENETRATIONS AND SEALING OF ME THE RESPONSIBILITY OF OTHERS 4.ALLOW 2'CONTRACTOR CLEARANCE WITH AIRROW OF 5 CFM PER IDO SQ FT AROUND ENTIRE PANEL SURFACES SMOOTH FINISH DISCLAIMER 5.GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATION MAMML FOR FLOOR DETAIL INFORMATION SCALE 6.QUARRY TILE OR CONCRETE FLOOR CONCRETE METAL PANEL FACING MAY BE SUSCEPTIBLE TO STAINING DUE TO EXCE59VE MOISTURE PLANT LOC. CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS.R IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED. 0 APPM YM-NO DIANGE REQUIRED,MANUFACTURE AS n <,ec�n. wrt.Da SPECIAL PRECAUTIONS MOST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO ERECTS HYDROCHLORIC RISES HAVE ON METAL MATERIALS DRAWN, Panels with non-textured and/or no-profile panel finishes(smooth finishes)on the Puw�F 2.PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS B.WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE ❑APPROVED AS NOTED-MAKE REQUIRED CHANGES AND exterior and interior faces may exhibit"oil canning"and flatness imperfections on the 9.IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 2C OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES MANUFACTURE AS DRAWN. 10.FLOOR.CURB,AND PIT DETAILS ME FOR GENERAL REFERENCE ONLY.THESE DRAWINGS MOLD NOT BE USED OR INCORPORATED IN THE surface. Our standard panels have a stucco embossed texture on both faces that helps to DESIGN OR PREPARATION OF THE INSULATED FLOOR,SUB-SLAB OR CURBS,WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED 0 NDTAPPRSEM-DESIGN CHANGES REQUIRE DRAWING reduce oil canning and any other irregularities in the exposed surface. Please be aware COLOR CODE ENGINEER.ALL FOOTINGS,FOUNDATION WALLS AID CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR REVISION AND RESUUBMISSION. ARCHITECT. of this potential situation in your specification process. Such"oil canning"and flatness 11.THE FOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS:FLAME SPREAD RATING:20;SMOKE DEVELOPED RATING:450;FLASH IGNTTxxN TEMPERATURE RATING:915N;SPONTANEOUS IGNION TEMPERATURE RATING:950N. DATE: BY: Issues are typical and are not covered under standard warranties. an D: • LT a M O N ..I O O a;_ < o DOOR ■ 181 ::•GASKET O 1!. it it it Ne-•T BOTTOM WALL L Z ._./- W p„ Z p EK _, -NISMED FLOOR , O d' J a 0 Ir cc AG ®DETAIL-FLAT BOTTOM Sczle:NTS 0 W G ce oC a F r .YERPLAT, O M a O DN / Nur � W /� ��P� u.Oi Q a CONIX/IT ASSBa ii../1 CEILING PANEL Bt. V O. o 1-1/1"OUL `� LEAD WIRE$TO BE W WALL OA_ \\PULLED TMRU CENG PANEL DOOR PANEL r ODETAIL-TIRO CEILING E L O ■ IT Scale:NTS �, m a 0 0 z _ E •IMOJT m.o. MN REFERENCE LAYOUT(S)FOR LOCATIONS AND FOR SPECIFICATIONS REFER TO GENERAL NOTES. FIAT BOTTOM WALLS 1 (SHOWN WITH OPTIONAL LY9NP®SCREEDS) (DETAIL-PANEL CONNECTION AT R.00RLES'- Q LO m N N n O K 0 O 4 4 LI SHEET 1 AD-4 of 7 r SCALE PLANT LOC. ■ COLOR CODE DESCRIPTION I QTY LVOLT I AMP J AMP LOAD VAPOR PROOF LIGHT 1 115 1 1 FLUORESCENT LIGHT 0 115 1.7 0 LED LIGHT 0 115 0.4 0 BEATER WIRE 1 115 0.5 0.5 DIGITAL THERMOMETER 0 115 0.1 0 HEATED AIR VENT 1 115 0.04 0.04 HEATED VIEWPORT 0 115 0.9 0 AIR SHIELD 0 115 1.4 0 IN/OUT BUZZER 0 115 0.1 0 MODULARM 75/75B OR DATALARM 0 115 6 0 OTHER ALARMS 0 115 1 0 115 VOLT,SINGLE PHASE,60 Hz,TOTAL DOOR AMPS: 1.54 • in ce Q1 FRAME: i O+ RECESSED 0"WITH 0"LEVEUNG SAND AND 0"TILE AND ' Ch GROUT 4 o I - EXT:GALVALUME-EMBOSSED 26 GA CO/�ii fl N I INT:GALVALUME-EMBOSSED 26 GA I i Es PLUG: VV0 iE :t it it C EXT:GALVALUME-EMBOSSED 26 GA r...EXT:KICKPLATE,ALUM.063 DIAMOND TREAD 36"HIGH Z Z C4 INT:GALVALUME-EMBOSSED 26 GA , 0 INT:KICKPLATE,ALUM.063 DIAMOND TREAD 36"HIGH K 4 0 ce ( 6 HARDWARE AND ACCESSORIES: I (1)LIGHT VAPOR PROOF MY "'� �� (1)BI-PARTING STRIP DOOR-3036 X 78 CLEAR-VU Z (1)OREGON SEAL OF APPROVAL L"1 (1)SWITCH-PILOT LIGHT INCLUDED UL Il (1)THRU CEILING ELECTRICAL(ALL CONDUIT CONCEALED) W (1)VENT-PRESSURE RELIEF,HEATED KASON 1825 v (1)THERMOMETER-2 INCH DIAL Ce 1 (3)THRESHOLD,STAINLESS STEEL 14 GA e (1)HANDLE-KASON 28(WITH LOCKING ASSEMBLY) !II (2)HINGE-KASON 1345 ADJUSTABLE(SPRING ASSTS itU) (1)DOOR CLOSER-KASON 1098(W/COVER AND HOOK) (1)HEATER WIRE,2.5 WATT/FT 0 W oft _ OFFSET—3.25 Z O 4 DR 36.00" x 78.00' W d t, '- FR 57.50' x 105.00" W O«W eg DViFl Ce Ce tat W D • ® . (5 g3$'0 A DOOR ELECTRICAL DFORMMT)DN --T--< - DESCRIPTION QTY VOLT AMP AMP LOAD VAPOR PROOF UQ{T 1 115 1 1 FLUORESCENT LIGHT 0 115 1.7 LED LIGHT 0 115 0.4 HEATER WIRE 1 115 0.5 .5 DIGITAL THERMCHETER 0 115 0.1 HEATH)AIR VENT 1 115 0.04 .04 HEATED VIEWPORT 0 115 0.9 Z AIR SHIELD 0 115 1.4 O IN/OUT BUZZER 0 115 0.1 MODULARM 75/758 OR DATAIARM 0 115 6 .. z OTHER ALARMS 0 115 1 ce 115 VOLT,SINGLE PHASE,60 FLT,TOTAL DOOR I.54 W 0 AMPS: y m w 0 O O z i LEGEND FE I Noh REFERENCE LAYOUT(S)FOR LOCATIONS AND FOR SPECIFICATIONS REFER TO Cr NFL;At NOTES. 4 CA 7 m N N n en IZ 0 ci cc 4 F SHEET U I AD-3 of 7 . SCALE PLANT LOC. COLOR CODE HEALTH DEPARTMENT NOTES: II M 1 • I.OWNER/OPERATOR IS REQUIRED TO TAKE OUT A SEPARATE HEALTH DEPARTMENT PERMIT.L r:4 2.ALL FOOD SERVICE AND RELATED PRODUCTS SHALL BE NATIONAL FS-0 COVER SHEET/NOTES a-1 SANITARY FOUNDATION(NSF)OR(UL)APPROVED FOR FOOD SERVICE. 3.CONSTRUCTION JOINTS,CRACKS AND CREVICES IN THE BUILDING OR FS-1 KITCHEN PLAN W CABINETRY MUST BE FILLED WITH AN APPROVED SEALANT/CAULK. 41416 Oil%4.WINDOWS THAT OPEN MUST HAVE A MIN.OF x16 MESH SCREEN. RECEIVE �I FS-1.1 EQUIPMENT SCHEDULE i DOOROCLOSU E O OUTSIDE AND WI REST AIR^CURTAIN.AND MUSTT NOTC FS-1.2 ELEVATIONS _ j w HAVE MORE THAW 1/4'MAX.FROM BOTTOM OF DOOR TO FINISHED Rx 6. EXTERIOR PASS-THRU WINDOWS MUST BE SCREENED OR AIR OCT I FS-1.3 ELEVATIONS • CURTAINED. /� 7.CONDUIT FOR ELECTRICAL.PLUMBING,REFRIGERATION,SODA OR ANY CO OF TIGIARD - - L R C• P .•N I OTHER SERVICE MUST BE CONCEALED IN WALLS.FLOORS,CEILING,OR ^, �,/� �1i, 1-1/2"OFF WALL WITHIN HEALTH DEPARTMENT APPROVED CHASE RUNS p LZZ 0 ex. BUILONS W�ISInv - P L : P A •• WITH END RUN SEALED TIGHTLY. I [-• �+V L/I1 V 8.TRASH/GARBAGE AREAS RECEIVING FOOD WASTE OR FOOD !, •l CONTAINERS MUST HAVE AN APPROVED TRASH DUMPSTER. Q 9.VERMIN PROOFING WILL INCLUDE BUT NOT LIMITED TO INSECTS AND �l, l RODENTS.THIS FACILITY IS TO BE CONSTRUCTED,MAINTAINED AND GENERAL CONTRACTOR NOTES: GENERAL CONTRACTOR NOTES:(CONT) O OPERATED AS TO PREVENT VERMIN.ADDITIONAL PREVENTION DEVICES �1� SHALL BE PROVIDED AS REQUIRED BY LOCAL AGENCIES. 1.FOOD SERVICE EQUIPMENT DESIGNER IS NOT AN ARCHITECT OR AN 14.G.C.TO CONFIRM INSTALLATION HEIGHT OF FLOOR SINKS WITH Q 10.FLOOR SINKS AND FLOOR DRAINS WILL BE INSTALLED FOR EASY ENGINEER.THESE DRAWINGS ARE PROVIDED FOR THE CONVENIENCE OF HEALTH DEPARTMENT PLAN CHECK. CLEANING ACCESS AND INSPECTION. THE ARCHITECT,GENERAL CONTRACTOR.TRADE ENGINEERS AND 6. SUBCONTRACTORS TO SHOW GENERAL PLACEMENT OF THE FOOD SERVICE 15.WALL FINISHES IN KITCHEN AND SCULLERY ARE TO BE INSTALLED W.AT LEAST WITH FOOD OR WORKING IN A WITH UTENSILS WHERE EQUIPMENT EMPLOYEE IS PRIOR TO INSTALLATION OF FOOD SERVICE EQUIPMENT. A, OVIMIME OWN WORKING WITH FOOD OR WORKING WITH UTENSILS OR EQUIPMENT SUCH EQUIPMENT.AS KNIVES,SLICERS,GRINDERS.OR SAWS WHERE EMPLOYEE SAFETY IS A 2.COORDINATE ALL PHASES OF CONSTRUCTION WITH FOOD SERVICE 16.WALK-IN PAD MUST BE SMOOTH&LEVEL FOR INSTALLATION. w - wh • FACTOR AND IN OTHER AREAS AND ROOMS DURING PERIODS OF CLEANING.AT EQUIPMENT CONTRACTOR.INCLUDING ADVANCE NOTIFICATION FOR ROUGH PRINCIPALS LEAST 20-FOOT CANDLES AT A DISTANCE OF 30'ABOVE THE FLOOR IN AREAS INSPECTIONS.FINISH PLUMBING,ELECTRICAL WORK,ROOF PAD 17.NON-COMBUSTALBE WALLS ARE TO BE PROVIDED AT COOKING USED FOR HANOWASHING,WAREWASHING,AND EQUIPMENT AND UTENSIL READINESS.ETC. AREAS IN COMPLIANCE WITH LOCAL CODES. STORAGE,AND IN TOILET ROOMS.MINIMUM OF 10-FOOT CANDLES IN WALK-IN 3.IT IS THE RESPONSIBILITY OF THE OWNER/GENERAL CONTRACTOR TO 18.G.C.TO PROVIDE WALL BACKING OF WOOD BLOCKING OR METAL ARCHITECT �`4 COOLERS/FREEZERS&DRY STORAGE AREAS. FORWARD ALL ADDENDUM'S AND CHANGES TO THE BUILDING PLANS FOR THE INSTALLATION OF SHELVES,FIRE SUPPRESSION EQUIP.. We S(e f n U C S I LI v f U u Q a r, WHICH ARE MADE DURING THE PERMITTING d CONSTRUCTION PROCESS. y P 12.CUSTOM STAINLESS STEEL WORK SHALL MEET NSF STANDARDS. LOCKERS.ETC.COORDINATE HEIGHTS WITH EQUIPMENT OWNER WILL BE RESPONSIBLE FOR COSTS INCURRED DUE FAILURE OF DAVID HARDISTER AlA N • SUPPLIER/ARCHITECT. 13.POT SINKS AND DRAIN BOARDS MUST BE LARGE ENOUGH TO HOLD COMMUNICATING CHANGES IN A TIMELY MANNER. 2300 EAST THIRD LOOP SUITE 110 Q` THE LARGEST POT/UTENSIL TO BE WASHED.DRAIN BOARDS ARE TO BE 4. ROOF TOP PLAN BY THE ARCHITECT/ENGINEER:PLATFORMS BY THE 19.WALK-IN SPRINKLERS BY G.C.IF NEEDED(PROTECT FREEZER VANCOUVER, WA 98661 v• Q EQUAL IN SIDE TO SINK COMPARTMENTS OR LARGER. G.C. SPRINKLER IF NEEDED).SPRINKLER PENETRATIONS BY G.CJFIRE 503-600-3284 ./a iz 14.CUSTOM MILLWORK/CABINETRY SHALL HAVE SMOOTH WASHABLE 5. ROOF,CEILING&WALL PENETRATIONS PROVIDED BY THE G.C., SPRINKLER CONTRACTOR. SURFACES.INTERIOR SHALL BE COVERED ENTIRELY WITH PLASTIC LAMINATE, CODE COMPLIANT CHASES TO BE PROVIDED AS NECESSARY.BY G.C.TO INTERIORS OF ALL CABINERTY SHALL BE WHITE OR LIGHT COLORED INSIDE. INCLUDE FIRE RATED SEALANT AS NEEDED. 20.G.C.TO VERIFY ALL INSTALLATION REQUIREMENTS OF OWNER OWNER 6.EQUIPMENT PADS.CURBS&ROOF JACKS/PITCH POCKETS BY G.C. SUPPLIED EQUIPMENT UTILITIES AND SIZING. o 15.EQUIPMENT SHALL HAVE 6'LEGS OR CASTERS.IF CURBS ARE 7,ROOF TOP EQUIPMENT TO BE LIFTED BY G.C. IL Boushe Pizza LLC CC PROVIDED FOR EQUIPMENT.THEY MUST BE A MIN.OF 4'IN HEIGHT 21.FLOOR DRAINS AND TROUGHS MUST HAVE FLOOR SLOPED PROPERLY. Renee & Brian Bourns WITH AN INTEGRAL 3/8"RADIUS COVE BASE&MUST BE SEALED TO CURB. 8. EXHAUST SYSTEM TO BE ENGINEERED AND SUPPLIED BY THE G.C. LL! 16.REFRIGERATORS ARE TO HAVE VISIBLE THERMOMETERS.PROPERLY FROM THE DUCTS UP.FINAL WELD OR CONNECTION BY THE G.C. 22.METERS SHALL BE ORDERED AND PLACED BY THE G.CJOWNER IN A CALIBRATED WIH DANGER ZONES CLEARLY DEFINED. CLEAN OUTS.FIRE RATED WRAPPINGSHAFTS AND ENCLOSURES BY THE TIMELY MANNER.DELAYS MUST BE ACKNOWLEDGED WITH EQUIPMENT KITCHEN DESIGNER Q G.C.AS SPECIFIED BY LOCAL ORDINANCES.BALANCE REPORT BY 17.MOP SINK TO HAVE HOT&COLD MIXING FAUCET W/ANTI SIPHON G.C./OWNER REPRESENTATIVE. SUPPLIER. MYERS RESTAU RANT SUPPLY, INC. O D DEVICE.CLEANING GOODS STORAGE TO BE ABOVE FAUCET. 23.DEBRIS BOX BY G.C.AND TO BE AVAILABLE FOR K.E.C.USE. `./ 9.G.C.IS THE FINAL AUTHORITY IN ASSURING THAT ALL TRADES JEFF MELTON I 18.HAND SINK TO HAVE HOT&COLD MIXING FAUCET AND COMPLY WITH STATE d LOCAL CODES. 24.PLUMBING&ELECTRICAL CONTRACTORS ARE RESPONSIBLE TO 1599 CLEVELAND AVE. �i\ PERMANENTLY MOUNTED TOWEL AND SOAP DISPENSERS. 10.PERMITS AND FEES ARE THE RESPONSIBILITY OF THE GENERAL PROVIDE ANY PARTS NECESSARY FOR FINAL CONNECTIONS. SANTA ROSA, CA 95401 �I V 19.FINISHED-FOOD PREPARATION AREAS: CONTRACTOR AND OWNER UNLESS OTHERWISE NOTED. T'� z FLOORS-COMMERCIAL GRADE VINYL,QUARRY TILE.OR POURED EPDXY FLOORING 11.SITE CONDITIONS TO BE VERIFIED BY G.C.,ANY VARIANCES TO BE 25.SODA SYSTEM MAY REQUIRE ELECTRICAL POWER AT SOURCE OF 707-570-1200 a BASE- CONTINUOUS SEALED COVING W/3B'RADIUS NOTED PRIOR TO CONSTRUCTION.KEC MUST HAVE ADEQUATE SITE& SYRUP. WALLS- FLOOR TO CEILING SHEET ROCK W/SMOOTH WATER BASED BUILDING ACCESS FOR PROPER DELIVERY AND INSTALLATION OF ALL 26.WALK-IN BOX TO BE WIRED COMPLETE BY ELECTRICIAN INCLUDING r1 ENAMEL PAINTED SURFACE W/70%REFLECTION. EQUIPMENT.INCLUDING OVERSIZED PIECES. BUT NOT LIMITED TO INTERNAL WIRING,DOOR HEATERS.COIL,HEAT �./ CEILING-T-BAR SYSTEM WNINYL COVERED GYPSUM TILES OR SHEET 12.CRITICAL TIME PATH TO BE GENERATED BY THE G.C.OR THE TAPE.SHUTOFFS AND COMPRESSOR. 4 Z N ROCK FINISHED W/SMOOTH ENAMEL PAINT. ARCHITECT. 27.WALK-IN BOX TO BE PLUMBED COMPLETE.INCLUDING BUT NOT SITE CONDITIONS �1 2 cV SAMPLES MUST BE SUBMITTED BY GC/OWNER 13.ROUGH-INS INDICATED ON THIS PLAN PERTAIN TO FOOD SERVICE LIMITED TO CONDENSATE DRAIN LINE. FIRE SYSTEM DRAWING NOTES EQUIPMENT ONLY. ADDITIONAL REQUIREMENTS INCLUDING 2g,G.C.SHALL BE RESPONSIBLE FOR ALL GENERAL AND FINAL OWER AVAILABLE:208/3 VERIFY Q CONVENIENCE OUTLETS AND AUXILIARY SERVICE TO BE PROVIDED BY CLEANUP INCLUDING PULLING S/S PROTECTION COVERING AND 1. FIRE SUPPRESSION DRAWINGS FOR CLASS!EXHAUST HOODS TO BE PREPARED OWNER,ARCHITECT AND ENGINEERS. FSEC TO PROVIDE ONE SITE TRIP REPOSITIONING EQUIPMENT AFTER TRADE HOOK UPS. ,;AS TYPE:NATURAL GAS BY A LICENSED FIRE SYSTEM INSTALLATION COMPANY AND WILL SUBMITTED BY CHECK OPEN STUD WALL UTILITY REVIEW. STRUCTURE TYPE: SINGLE STORY 0 N SAME UNDER SEPARATE PERMIT.FIRE SYSTEM INSTALLATION CONTRACTOR 29.SEAL ALL CRACKS AND CREVICES IN COUNTERS.AROUND METAL NEW CONSTRUCTION OR REMODEL:TENANT IMPROVEMENT UNDER CONTRACT THROUGH FSEC. LOCATIONS OF FIRE PULL STATION(S)TO BE FLASHING.AND CONDUIT WON-HARDENING SILICON SEALANT. CONFIRMED WITH FIRE MARSHALL PRIOR TO ROUGH-IN. CEILING HEIGHT AT COOKLINE AREA: 9'-6" VFY (/) 0 CEILING HEIGHT IN BACK OF HOUSE AREA: 9'-0" VFY .. HEIGHT TO BOTTOM OF TRUSS OR BEAM: 12.-0" VFY Q ABBREVIATIONS KITCHEN CEILING TYPE: T-BAR O/� ROOF TYPE: FLAT MECHANICAL WELL, CONFIRM H STATE: OR COUNTY: WASHINGTON COUNTY, OREGON T I AND CEO DUPLEX CONVENIENCE OUTLET INT. INTERIOR REINF REINFORCING OVERALL SQUARE FOOTAGE: 2522 SO.FT. L ANGLE E) EXISTING KEC KITCHEN EQUIP. CONTRACTOR RHWS ROUND HEAD WOOD SCREW S AT EACH L LENGTH RHR RIGHT HAND REVERSE _INEAL FEET OF DRY STORAGE SHELVING: 36 L.F. X Z O DIAMETER ELECT ELECTRICAL LAV LAVATORY RM ROOM '5 SHELVES PER UNIT = 180 L.F. UJ DEGREE EQ EQUAL LF LINEAL FOOT RO ROUGH OPENING 2 H POUND OR NUMBER EXT EXTERIOR LH LEFT HAND RWE RAINWATER LEADER ';EAT COUNT: 56 INTERIOR; 20 PATIO . W S SQUARE FOOT FE FIRE EXTINGUISHER LHR LEFT HAND REVERSED SCD SEE CIVIL DRAWINGS "ABLE COUNT: 19 INTERIOR; 5 PATIO AB ANCHOR BOLT FEC FIRE EXTINGUISHER CABINET MAX MAXIMUM SCH SECTION 5 W ACOUS ACOUSTIC FHWS FLAT HEAD WOOD SCREW MB MACHINE BOLT SED SEE ELECTRICAL DRAWINGS uJ W ACT ACOUSTIC CEILING TILE FIN FINISH MECH MECHANICAL SIM SIMILAR NOTE: PRINCIPALS TO REVIEW & ADVISE IF CONDITIOM.: ACH ABOVE COUNTER HEIGHT FLR FLOOR MFR MANUFACTURER SW SEE MECHANICAL DRAWINGS W AFF ABOVE FINISHED FLOOR FOC FURNISHED BY OWNER MIN MINIMUM SINS SHEET METAL SCREW VARY U [[ ALUM ALUMINUM INSTALLED BY CONTRACTOR MISC. MISCELLANEOUS SPD SEE PLUMBING DRAWINGS ycr: CC ARCH ARCHITECTURAL, ARCHITECT FOS FACE OF STUD MIW MAL IRON WASHER SPEC SPECIFICATIONS BD BOARD FOSTL FACE OF STEEL MOD MODULAR S/S STAINLESS STEEL > BLDG BUILDING FRP FIBERGLASS REINFORCED PANEL MTD MOUNTED STD STANDARD SCOPE O F WORK BLKG BLOCKING FT FOOT OR FEET MTL METAL STL STEEL O 0 BM BEAM FTC FOOTING (N) NEW STS SELF TAPPING SCREW 0 BOT BOTTOM GA GAUGE NIC NOT IN CONTRACT TAG TONGUE A GROVE BTC BRANCH TO CONNECTION GALV GALVANIZED NOM NOMINAL TOB TOP OF WALK-IN BOX NEW CONSTRUCTION TO CURRENT CODE COMPLIANCE 0 f CENTER LINE GSM GALVANIZED SHEET METAL NTS NOT TO SCALE TOP TOP OF PAVEMENT CLG CEILING CWB GYPSUM WALLBOARD OC ON CENTER TOF TOP OF FLOOR ,,,,D COL COLUMN GYP GYPSUM OD OUTSIDE DIAMETER TOS TOP OF SLAB/STEEL COMP COMPOSITE HEIGHT H OR HGT POP POWDER DRIVEN PIN TOW TOP OF WALL CONT CONTINUOUS HB HOSE BIB PH PANIC HARDWARE TS TUBE STEEL CPT CARPET HHS HEX HEAD SCREW E PLATE OP TYPICAL DBL DOUBLE HM HOLLOW METAL PLF PER LINAL FOOT UNO UNLESS NOTED OTHERWISE DAM DETAIL HORIZ HORIZONTAL PLAM PLASTIC LAMINATE VCT VINYL -- - DIM DIMENSION HVAC HEATING-VENTILATION- PLYING PLYWOOD VERT VERTICAL oso®sn DSA DIVISION OF STATE ARCHITECT AIR CONDITIONING PR PAIR W WIDTH DWG DRAWING ID INSIDE DIAMETER PSF POUNDS PER SQUARE FOOT W/ WITH COMM ft V, WO WOOD SCOPE OF FOOD SERVICE ""s DARE QUICK SERVICE STYLE RESTAURANT OPEN 7 DAYS A WEEK FOR 3 20 1 DISCLAIMER LUNCH & DINNER. COUNTER ORDER& PICK UP. SERVICE ON PAPER/PLASTIC. .be nn MYERS RESTAURANT SUPPLY, INC. (MRS, INC.) DOES NOT REPRESENT THEMSELVES AS PROFESSIONAL ARCHITECTS OR ENGINEERS. THESE PLANS ARE NOT PROVIDED AS A RESULT OF AN AGREEMENT FOR THOSE PURPOSES. THESE PLANS ARE PROVIDED ON BEHALF OF • THE PROJECT OWNER FOR THE CONVENIENCE OF THE PROJECT ARCHITECT OR ENGINEER AND THE CONTRACTORS TO LOCATE THE FOOD SERVICE EQUIPMENT AND THEIR RELEVANT UTILITIES AND TO ASSIST THE ENVIRONMENTAL HEALTH DEPARTMENT IN ACCESSING THE SHEET RELEVANT SUBMITTAL INFORMATION. CURRENT TECHNICAL INFORMATION HAS BEEN UTILIZED AND MRS, INC. WILL ASSIST IN THE RESUBMITTAL IN THE EVENT A PRODUCT OR SPECIFICATION HAS NOT MET CURRENT CODE. THE OWNER WILL CONFIRM TO THE ELECTRICIAN AND PLUMBER UTILITY REQUIREMENTS FOR OWNER SUPPLIED EQUIPMENT AND VENDOR SUPPLIED EQUIPMENT. CONTRACTORS MUST VERIFY UTILITY LOCATIONS AND APPLICABILITY TO THE BUILDING PRIOR TO COMMENCEMENT OF WORK. DISCREPANCIES ARE TO BE REVIEWED. FS-O ADJUSTED AND SIGNED OFF PRIOR TO WORK. SUBCONTRACTOR ALLOWANCES OR BACK CHARGES WILL NOT BE ACCEPTED. QUALITY OF WORK. JOB SITE CONDITIONS, LABOR DISPUTES OR CONTRACTORS AND ADHERENCE TO CODES ARE THE RESPONSIBILITY OF OTHERS. MRS IS NOT RESPONSIBLE FOR ADA (AMERICAN DISABILITIES ACT) REQUIREMENTS NOR TITLE 24 ENERGY CONSERVATION REQUIREMENTS. THESE PLANS REMAIN THE PROPERTY OF MRS. INC. UNTIL ASSIGNED TO PROJECT CLIENT. ISSUED 7.14.i 1 4 _ t r 1 f*- NOTE: CLIENT TO REVIEW WITH ARCHITECT THE FINAL LOCATION OF ALL PO5, Q V) z a a l PRINTERS.TELEVISIONS,TELEPHONES,AUDIONIDEO EQUIPMENT.SECURITY. • LIGHTING SWITCHES.OFFICE EQUIPMENT,COMPUTER UNE RUNS,TIME CARDS 0 Q AND TIME CLOCKS. THESE COMPONENTS ARE TO BE REFLECTED ON PATIO SEATING .) +mommlismom- ELECTRICIAN'S PLANS GENERATED BY ELECTRICAL ENGINEER. elm—_ A ^ ¢a g. • +at « inn 1 L :':PS-11 '.)�.1 II Cownaw Eou.roH 1111 ��l/AAIL�� !!ll = V.STATION p va+ate+o«HCC �I IJ ,.,-.Dp.. ,. / Q �'� �'� ® TABLES W/ f:'Le) \ 8 ® .../a. `� I WI IB :— ' elec Mill ° S • Liu x • .et — W .JEF AI /II Err il1OMW.,A.,- likrilp ti, ./4kt rr-) (�I II) « 1 nii► ° I 1 : II o vase CI -: s 4W. 0 III MN' aim&P-1 Jim e) I ' frolill'a - ' II i_ipla Id 1■..m.1■...m mr: 71 .,_.-sr. 1 ers ri (2;__i H .. q.-) _ (■I I■) � © oven seer. amr 11 O 32 34 No M.N. DATE . 0 .- :,-) / I!I, _.. . . . _ e.. �I ® a , 3' , ;_, iii,P0 _J ill /3 71 Smoak H t ..■ L��fl 46\ Rte!Maw °tii► 2 fl I ■�� , �r Ir=e ' ±�� , w GU.oil . e ■�� •�% ID �1 .,u.,.11. L_ t4) ••• mi; Iir emv ®u..n _.� �� — - Raenr lr z �a ode V lr.ichatle G� EATE YOUR OWN I N ei▪n.te FLOOR PLAN 0 u) N. Jalapeece.r...P.. PICK ONE GF GtI*5 SC.NLE:I/a=r{I ......111 CC a.r AMU DOMES O O Routed m.eppare red eau.,eos:.relle.P•PO•ro 1,.awRti..t..E1,oil..ail hank Pepe, d- hb.t'l.wsmellw. .a..11M,praonule,chicken,red onion,Ere.cilantro, ass 114 a blq moo,olive oil>sP apes. Dn11nP of.e ewe .on_erell4 eeesn,ricotta,freed,50S ll..Lek pepper,of i.e oil ....reL,per...,...to,11.1 tr14 Rrllc,olive oil � O ,,— I- .....,11.,P....,.o...nd red MN....R.rl1q Nato,all.all T q .oe..ac1L,per...,.rtle.oken,alie.ail,dollop.or red stile an top Z b •f ti0t.n-free*C**0.0 40 I FM 1Ir l.aeCf pq. d 5-At—ADS REMOTE EQUIPMENT o CL SCALE 1/T-F-0- C.) CC > 0 cc 0 • music a_cool orgn is green,e�neola.thicken.craic]ne.candied wn_nutoe LLI W w/x'eaPDeny vinaigrette O O LL CA RriAR I rousing neerts,nhicknnv.Med Fwneeean l•eeRP,eroatnn&RRnear drmRing O LL Full-eve and Batt-sirs(no chickelil available LEGEND _ ABBREVIATIONS .LPRO� 1 1 FULL HEIGHT WALLS St PARTITIONS ∎,LC=FOOD SERVICE EQUIPMENT CONTRACTOR f!T,5 ® STUB WALLS&CURBS(VERIFY HEIGHT) PC=PLUMING CONTRACTOR DATE DATE ITEM NUMBER IDENTIFICATION SYMBOLS EC=ELECTRICAL CONTRACTOR f MAW VP JM g ELEVATION SYMBOLS GC=GENERAL CONTRACTOR MAW MG KERB HOTTER ca.QI]FBAtICB SUGAR O=OWNER ]O PLUMBING MARK LAN) (SEE PLUMBING PLAN) HVAC=HEATING/VENTILATION CONTRACTOR teas *I Gluten-4ee cruet available 1 Q ELECTRICAL MMN SYM @OL NTS=NOT TO SCALE ONTO • (SEE ELECTRICAL PLAN) EXIST=EXISTRIG S-20 1 4 L REVISION NUMBER VFY=VERIFY JOB NO *Although our crust is made w1t11 gluten-fret ingredients,we carrot guarantee that our pintails EQUIPMENT V I.F.=VERIFY IN FIELD IDO4 free of gluten an there is always a possLEl.Tlty of trace amounts crossing over IIoa other — — — EQUIPMENT -ABOVE • latches areas and suppliers'In gredlents changing.Please cons7der Lois when ordering Fro.CMS EQUIPMENT - HIDDE\ menu. FS-1 ISSUED 7.14.14 ( ? 1 E Q U I P M E N T S C H E D U L E tJ w 2' 3 V Z z � � IIa N 4 43 K.- a . T. , ITEM x w z K?v 1 a -,0_�,8 W wz & uM o�.6-,,...-w N SN N Om REM ITEM �r I NO QTY EQUIPMENT CATEGORY MANUFACTURER MODEL NUMBER w • x a w< z �z A R min"x out ?v can W 7 REMARKS I --SPINE NUMBER I if THE SNEEZE GUARD DOES NOT BUTT UP 1,'4 a-, 2 1 MOP SINK&SERVICE FAUCET CC X 2 0.3 36 0.5 36 2.0 FAUCET TO HAVE ATMOSPHERIC VACUUM BREAKER 2 AGAINST A WALL OR DISPLAY CASE 149 " 3 I WATER NEATER GC AD SAAN1 BRA-120 X 82 120 1 X 30 3 0.5 24 1.0 30 120 e0 C LLON RESEVC.R.230 GPH AT 50' AN RISE;SEE MECHANICAL PUNS 3 NSF COMPLIANT AT ENDS,AN END PANEL WILL BE PROVIDED W p♦ , LT OW STORAGE SHELVING ADVANCE EC SERIES X l 7:POSTS,NO CASTERS;5 SHELVES PER UNIT ! HEALTH CODE 7 CUNT NUING BACK 18• PERPENDICULAR TO THE �'h 4. 2 TRAY DRYING SHELF-15 CAPACITY FOCUS FTS2448615G N X • Q 4.1 2 TRAY OWING SHELF-35 CAPAcny FOCUS FI524406357N X 43 7:POSTS,NO CASTERS 4.1 POINTS X SNEEZE GUARD. -+l i 1 WET STORAGE SHELF FOCUS F72440C X 60 Gl 5 2 EMPLOYEE LOCKER,6 HIGH GSW ELS-60R X 5 ATTACH LOCKERS TO WALL...CAA LEGS.MOUNTED fi OFF FLOOR FOR CLEANING BELOW 5 OTENTIAL CONTAMINATION 6 1 FAX MACHINE OWNER X ISA 120 1 X�NZ- 6 CONFIRM UTILITY REQUIREMENTS W/DINNER;REFER TO MECWNICAL PLANS FOR MORE INFORMATION 6 ZONE 7 I COMPUTER OWNER X T5A 120 1 X ni 7 - CONFIRM UTILITY REOOIEYENR W/IXYNER:REFER TO 4ECHWPJA PLANS FOR MORE INFORMATION ] �` 6 I COMPUTER PRINTER OWNER X 15A 120 1 X 18 6 CONFXM UTILITY REOUREMENTS VI/OWNER,REFER TO MECHANICAL PLANS FOR MORE INFOMATCN 6 X= 7.5^ ADO] 9 1 COPIER OWNER X 15A 120 1 X 16 9 CONFIRM UTILITY REQUIREMENTS VI/OWNER REFER TO MECHANICAL PLANS FOR MORE gNF0114ATgN 9 ,, Y= ZO.5� , ..y 10 I MILLWORK DESK t SHELVES MILLFAB X 10 10 A/Lb\ \`Y= 5.5° 11 I CHEMICAL SHELF AOAANCE W5-12-24 X 11 11 \ 12 I MOP HOLDER OWNER X 12 12 Q 13 1 BA:N THE BOX RACK t REOJITORS VEAOOR X 5.0 120 I X 64 13 0.3 84 I POWER FOR CARBONATOR/CONFIRM 8/SODA VENDOR 13 a 1 LT CO2 TANA VEN00R X 14 I CC.TO ENSURE TANKS ARE SECURED TO WALL PER CCOE 14 - IS I LT S/S CORNER GOURDS-FULL 40001 CUSTOIFA X 15 - IS 0 16 1 FIRE-@VISE FAUCET,WALL MOUNT•/FAUCET i13KR __ ]210-ILB[]91.1-11 X 16 0.5 16 0.5,16 ACCESSORIES:[2)2200-0000:[21 2400-2103 16 I /• ® 17 1 WAIL-MOUNT SHELVW4G O PREP 5INK ADVANCE EG-1436:58-14 X 17 _ I(1 / 10 1 PREP SINK AOJAYUE�y -fr-1-x624-�4L-% X 10 1.5 LEVER WASTE I8 / Q 19 1 30 OT-MIXER 405841 4L UM 300-3 X 9.5 100-120 1 0.75 X 48 5-ISP 19 ACCESSORIES: 11-]O:HLVS9-12:V59110LD-91612:V59PLT:VSSPLT-3/165! 19 / 20 2 LAND SINK W/SIDE SPLASHES ADVANCE 7-P5-23-20 X 20 0.5 16 0.5 16 1.5 ACCESSORIES:7 3/C HIGH SLOE SPLASH BOTH SLOES 20 21 1 S/S WORKTABLE W/UNOERSREIF AWAKE iKYAAG-]O]-% X 21 _ 21 / Oxa1R N. MAW Ls 21.1 I CAN OPENER EDLUND /1 X V.1 _ 21.1 ILO PENNON WI • 22 2 COWER./SOAP t TOWEL DISPENSER VENDOR X 22 _ 22 / A 22.1 2 S/S GLOVE BOX DISPENSER CUSTOM FA8 X 22.1 22.1 wy 23 • WALL-MOUNT SHELVING O POT SINK ADVANCE EC-1436:58-14 X 23 - 23 Y 24 I PRE-5450 FAl10Ei,WALL 4WM•/FAUCET - - X _ 24 0.5 IN 0.5 16 - I�I O ®23 1 TINES(S)COMPARTMENT SINK CE FC-3-1824-24RL-400 25 3 ,ACCESSORIES:[21 2200-0000:[2)2400-2103 25 G • 2 ®26 2 CHANCING TABLE - X 26 INDIRECT DRAIN TO FLOOR SOAK 26 N 27 1 CAN RACK,MOBILE ADVANCE CRIO-1624 X 27 $7 SNEEZE GUARD SECTION 0 O N 28 1 WALK-8 COOLER KDLRIK X 6.0 120 1 % 112 28 @01114,M:9'-0 NNW S11.CW DIBOSYU WORD S1Rl:N.OB'WK-n DOOR WO f4AY1 n DOOM INC NT:R-NOU 2B _ MpW4EW-[N S VEN PLUMY WOO MK RATE A/ON:Ill VOW PROOF ME 10 MEEI O EXCEED 30 FL CNOLS AT.M" 29 v Q 29 I REFRIGERATION POWER PAKNfZS X 8.5 MI6-zb 1 1.0 % 112 29 NT.$Elf-CQIYF(9 M6WRMROR MI01 DRS TIM MEWRE•mAw Lit-xM ssrtM SCALE:1'-I'-0' JA. A 30 2 PACK.DUNNAGE A[IVANCE OLIN-2460 X 30 _ - et Y A 31 4 WAR-MOUNT S■ELWNC O wWRKTARLE MANGE EC-1436:S11-14 HX 31 31 N 32 I LT EP000 COOLER SHELWNC `ADVANCE V EC SEATS _ ` X 32 I I }} A 33 I 4EA1E0 DOUGH PRESS OOXYAROV DR1301r X 22.M 4.6K 208 1 '4 46 6-30P 33 0 34 1 WORN TABLE ADVANCE KNSUG-308-x X _ 34 _ _ 6 LEGS;REAR SPLASH OR TABLE N SHOES THAT DO NOT HAVE A PASS WINDOW BEHIND THE TABLE 34 CC 35 I OERSNELF•OVEN w/RCKET PNL ADVANCE WS-13-72-CM X 35 35 . LL A 36 1 RITE DECK OVEN DOUGH PRO DFORECT966GF0 X - _ 5.0 120 I X .12 36 0.75 12 143 P.C.TO DIRECT PIPE CAS W/ACCESSBILE SNOT OFF 36 M\X�\J11 J 37 1 EXHAUST X000(PIZZA I1VEN) CAPTVAR J624ND-Z X 3.0 120 1 % 104 37 71 36 1 S/S MOBILE WORKTABLE w/UNOERSHELr ADVANCE KYSLAG-309-0 X _ ._ 38 - ACCESSORIES:SPLASH AT WALL 36 39 1 OKRSHELF•FOOD WARMER W/1CKET RAIL ADVANCE W5-15-108-CM X _ - 39 39 Q A 40 I 05403515 SYSTEM w/WATER FILTER ESERPURE I EV997007;0N34469:R015:58033 X I5A 120 1 X 84 40 .5 98 P.C.TO PRE-PPE IN WAIL F/WATER FILTER LOCATION TO ROUGH-IN LOCATON BELOW PREP 40 SINK FOR RESERVOR TANK.THEN FLEX LINE TO FILL FAUCET MOUNTED ON WALL BESIDE SINK \ \ g Q 1 RESEVOIR TANK EVERPURE X 19 _ _ DRNNB0040 AT 40 AFF.WATER FOR 0000)1 PRODUCMIN ONLY EVERPURE TO PROVIDE CUSTOM_ \/M:V\)1 A I FACET 0/BRACKET EAERPKWE X 40 S/S BRACKET FOR FAUCET TO MOUNT TO WALL 41 l 2 DUNNAGE RACK ADVANCE OUR-2436 X Al J�.L 42 I FIRE SUPPRESSION STOILM CAPNAR AX5UL X X 104 42 _ a2 M A 43 I •8"SANDWICH TOP REFER(MEAT) TRUE 155V-46-104-8 X 6.6 115 1 0.33 X 18 5-ISP 43 FLAT LID 92005NT 43 ,F� M I AB"SANDWICH TOP REFER(SAUCE) TRUE TSSU-43-161A-B X 5 5.6 115 I 0.33 X 16 5-15P 44 FAT LO 920053F1 44 0 ®45 I 46"SANDWICH TOP REFER(TOPPINGS) TRUE TSSU-46-18M-8 X 6.6 I13 1 0-33 X 18 5-15P 45 RAT UD 920053R 45 I- •6 I PORTABLE COAT FOCUS 90322 X 46 18X30-;4 33"POSTS W/CASTERS:3 SHELVES:CHROME HASH 46 O ®47 1 S/S WORKTABLE ADVANCE Y5-303 X _ _ 47 - 1 I ACCESSORIES:TA-22:TA-33-34"HIGH:TA-37;ENCLOSE BASE ON 149 SIDE:SQUARE EDGE 47 Z 46 1 S/S OVEN t HOOP MN CUSTOMFA X M 49 1 REFRIGERATOR,KR CURTNN TYPE TRUE TIC-4R-S X 9.4 115 1 0.35 X 4.5 5-15P 49 ACCESSORIES:2"DUAL*REEL CASTERS:EXTERIOR STAINLESS K = C\I 50 1 EXHAUST FAN CAPTVAR DUSONA X I 5.6 I 115 1 0.5 A ROO. 50 U REFER TO IAECON4CAL PLANS FOR INFORMATION ON MAKE UP KR UNR SO O C/N N. 51 I AR COMPRESSOR GC x 208 120 1 X 120 51 _ IE9 6 OR•110 P9.DM 0T 1E51 WS BI LEA WM KN!.ON 41 100 79 WE 4 175 P51 3/6'NOUt4NWE ANN 10 133 51 V A N. 52 2 P05 SYSTEM OWNER X IsA 120 1 K 10 52 VIA POWER AT 10"Ar k BRNKX TO CW401ONS DAD 0URE1.CUOMO)CWNM:OM CAME HOVE RA TO OTCE52 < K 52.1 3 ORDER PRINTER OWNER X 3.0 120 I X N 52.1 _ DATA CABLE:HOME RUN TO OFFICE:POWER ABM SHELVES 38 t 39 52.1 CC 53 I S/S PIZZA GI PAR LEDGE CUSTOMFA X I _ _ 54 O O 54 I SNEEZE GUARD Cl/STOEA X 54 SEE DETAIL ON FS-1.1 54 55 1 S/S BEVERAGE COUNTER CABINET ADVANCE 4N-SS-3694 X 55 - SRN PORN OEM C0 k 6MNCI 1O CONNECTOR OYES OWLET:ROCARD ORM 010 GAEL ILA RUIN ORES 55 Cl)56 1 BEVERAGE DISPENSER VENDOR X ED 120 I X 14 56 0.5 12 0.75 CONFIRM UOLO1ES W/SODA VENDOR 56 U) 0 57 1 ICE MAKER W/0 BIN MAMTOWOC IV-1004A X 13.5 208 I x 60 57 0.375 60 03 FILTERED WATER FROM 066 VM 5004 LINE 57 ` �y 5 56 I ICE WAXER ADAPTOR KIT VENDOR X - 36 58 W •V 59 2 PORTABLE RACK OWNER _ _ X • 59 58 A 60 1 WARMER.FOOD.ELECTRIC SERVER 5-1/3 88090 X 3.3 0.4_ 120 1 X 16 5-15P 60 80 \ O 61 1 ICE TEA DISPENSER/BREWER OWNER X 158 120 I- X 46 WY 61 0.5 14 CONFIRM UTILITIES W/OWNER 61 Q 2 62 1 62 1 UO HOLDER OWNER X 6 - F . N 1 CONDIMENT HOLDER OWNER X 63 _ 63 64 1 RAPKN WAXER OWNER X - OL 64 64 AS 1 S/5 TRASH RING CUSTOMFA X 65 65 66 1;T TRASH/TRAV OWNER x 66 68 w 47 S/S POS COUNTER CUSTOMFA X ' _ 6] ACCESSORIES:[21 TA-27:CASH-I,[2]TA-65 67 d 67.1 1 S/S POS CARNET W/8•LEGS ADVANCE CB-55-365 X 67.1 RELOCATE IN FUTURE. ACCESSORIES:1 SECTION OF TRAY SLOES AT LEFT END 67.1 - Z LL • 68 1 GREASE RECOWERY SYSTEM CC X 66 VFY REFER TO MECHANICAL PLANS 46 Q W 69 1 LT Gw+RS(LOW) OWNER X 69 Q 70 1 LT MILLWORK TABLE TOPS MILLr•B X 70 TO LU - 71 1 LT TABLE BASES MILLFAB X 71 71 U CL LU 72 1 SETTEE MILLFAB X 72 2 72 > D U 73 I SETTEE NLLFAB X 73 - 73 CC 0 74 L[J 4 74 --SPARE 6 COA _ _ 75 75 Q 75 1 MILLWORK COMMUNITY TABLE(LOW) MILLFAB X 76 I LT 1601 EATING COUNTER MILLFAB X 76 76 ("� 77 1 LT CZARS 0603) OWNER X - 77 - 77 l8 70 1 LT DINING PAR111105 WALL MILLFAB X 78 TB CL- 79 t LT PAM TABLES MILLFAB - X 79 - 79 BD I LT PATIO TABLE BASES MILLEAB X - 80 80 AFRIT® RI 1 LT PAT10 CHARS OWNER X 81 61 82 1 LT ASSEMBLY PARTITION WALL MILLFAB X 82 62 83 I LT S/S WAINSCOT CUSTOMER X R3 83 DATE 6 64 1 LT 6'5/5 COVED BASE THRU-OUT DIMING AREA CUSTOMFA 346 LE. X 64 04 - - 85 I LT S/S RW1 HASHR0-BEVERAGE STATION CUSTOMFA X `- 85 85 CEAIOJE9 BT V 66 I WATER FLYER FOR ICE RARER MANITOWOC AR-20000 X BR 0.5 96 ROUTE W/SOH UNES 11641 CASE TO OVERAGE STATION FOR KR MAKER 86 MANNER VG A 87 1 ROBLE°HEATED CABINET IATCO PEST-IX X 14.5 1.74 120 1 X 16 5-15P 67 87 88 --SPARE NUMBER OR - KAUAI 89 --SPARE NUMBER 49 _ - 90 DAIW • SI --SPARE MJ11�R - - 91 3.20.14 90 9I --SPARE MUYBER Al - 92 1 S/S 000E FRAME CC X 92 , 92 AMINO. A 93 1 BI-SWINGING DOOR CC X 93 93 A 94 5 5/5 HMG ON SCRAP BASKET CUSTOMFA X 94 KEY HOE 441NG ON ATTACHMENT 10,041 44.45,36 t 34 94 95 --SPARE NUMBER 95 95 SHEET • 96 1 SASE NKL INTELUSAEE 0503220 X 154 120 1 X 18 96 _ 96 - A 97 4 NORZONIAL CUP DISPENSER SAN 4AMAR C3403CR X 97 INSTALLED IN/67 97 A 98F 1 BEER DISPENSER TRUE TOO-2CT-S X L1 _ 11S 1 0.43 X 16 5-15P 98F 0.5 , ALE TO CONFIRM F.S.REOLRES TRAP MAZER. OW FS 1 .1 A 99F 1 U/C DSHwASNER-FUTURE HOBART 1901-2 X 30.5 120/208 I 0 18 99 97 A 100F I LT RR NITROGEN TANKS FOR OUR VENDOR X - 100 - - I - 91 ISSUED 7.14.14 PIEOLOGYY Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 10114 SW WASHINGTON SQUARE RD, TIGARD, OR, 97223 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2014-00544 Chip Barnett Violation Summary: Inspector Contractor