Specifications • cps Rev -evens' FRsaa-o-9-a-va F'P5o2ev9-0-0el?" F/05,9_0-09.- ev07 3 FPS a,or-t)9 -e vv a° „20--4,c7 - ES-A-C300/C300N Colt” Series C300/C300N A M E s FIRE&WATERWORKS'" Double Check Detector Assemblies Sizes: 21/2' — 10' (65—250mm) • C30003Y 3OOBFG . _ b. .1111 617 . �^R I r • I rit { ,w a - - Features The Colt C300/C300N Double Check Detector Assemblies are used to prevent backflow of pollutants,that are objectionable but not toxic, from • Extremely Compact Design entering the potable water supply system.The Colt C300/C300N may be • 70% Lighter than Traditional installed under continuous pressure service and may be subjected to Designs backpressure.The Colt C300/C300N is used primarily on fire line • 304 (Schedule 40)Stainless Steel sprinkler systems when it is necessary to monitor unauthorized use of Housing&Sleeve water. For use in non-health hazard applications. • Groove Fittings Allow Integral Pipeline Adjustment Specifications • • Patented Tri-Link Check Provides Lowest Pressure Loss The Colt C300/C300N Double Check Detector Assemblies shall consist Unmatched Ease of Serviceability of two independent Tri-Link Check modules within a single housing, • sleeve access port,four test cocks and two drip tight shutoff valves. Tri- • Available with Grooved Butterfly Link Checks shall be removable and serviceable, without the use of Valve Shutoffs special tools.The housing shall be constructed of 304 (Schedule 40) • May be Used for Horizontal, stainless steel pipe with groove end connections.Tri-Link Checks shall Vertical or N Pattern Installations have reversible elastomer discs and in operation shall produce drip tight • Replaceable Check Disc Rubber closure against the reverse flow of liquid caused by backpressure or backsiphonage.The bypass assembly shall consist of a meter, which registers in either gallon or cubic measurement, a double check valve assembly and required test cocks.Assembly shall be a Colt C300/C300N as manufactured by the Ames Company. Job Name Contractor Job Location Approval Engineer Contractor's P.O.No.__ Approval Representative Ames product specifications in U.S.customary units and metric am approximate and are provided for reference only.For precise measurements,please contact Ames Technical Service.Ames reserves the right to change or modify product design,construction,specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold www.amesfirewater.com . Configurations Available Models • Horizontal Suffix: nt ■il • Vertical up OSY- UUFM outside stem and yoke resilient • "N"pattern horizontal seated gate valves BFG- UUFM grooved gear operated butterfly valves Materials with tamper switch • Housing&Sleeve:304(Schedule 40)Stainless Steel • Elastomers:EPDM,Silicone and Buna'N' Pressure — Temperature • Tri-Link Checks:Noryl®,Stainless Steel Temperature Range:33°F-140°F(5°C-60°C) Maximum Working Pressure: 175psi(12 bars) • Check Discs:Reversible Silicone or EPDM • Test Cocks:Bronze Body Nickel Plated • Pins&Fasteners:300 Series Stainless Steel • Springs:Stainless Steel Dimensions — Weights -T I gig ....i J g Aillil II;a If - C(open) _ALL ON.- - . mt, I H A G ----- P - C300/C300N SIZE(ON) DIMENSIONS WEIGHT A C(OS1) 0 G P C300 C300N in. mm in. mm in. mm in. mm o. mm in mm lbs. !cgs. lbs. kps. • ' 1 787 161/4 41. 'r :• ''16 r ■ 3 . ' 63 14 .7 :I 111. :I : EI � 'T W 'T EIVII 1 7: 4 100 33"/I6 856 223/4 578 4 102 33 838 24 610 181/2 470 9'1/46 252 151/46 386 175 79 198 90 6 150 44 1118 30% 765 51 140 441/4 1137 333/4 857 231/46 589 131/46 332 19 483 309 140 350 159 8 200 50 1270 373/4 959 611/16 170 54% 1375 40% 1032 27'/46 697 15 1'/16 399 213/46 53$ 494 224 569 258 10 250 571 1460 453/4 1162 81/46 208 66 1676 50 1270 321/2 826 171/46 440 24 610 795 361 965 438 ." Pall ll x.111 ■IMP' 11 ,. jig I■ MI o Eiu� E 1. r '-Joni. :;lr .I I I A t [ H 1 1 P i C300B300N8FG G FG/C SIZE(ON) DIMENSIONS WEIGHT A C 0 6 H I .1 P C3006H6 C300NBFG in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kps. lbs. kgs. - 21/2 65 28 711 8 203 31/2 89 29% 759 22 559 14'1/46 379 811/46 223 13 330 70 32 78 35 ✓ 3 80 281/2 724 85/16 211 3"/16 94 30"/6 779 223/4 578 157/16 392 99'16 233 131/2 343 68 31 81 37 4 100 293'46 741 81356 227 3'16 94 311156 811 _ 24 610 16'% 412 915/16 252 14 356 75 34 98 44 6 150 3611 927 10 254 5 127 431/46 1097 33% 857 19'1/46 500 131/46 332 14% 368 131 59 171 78 8 200 43 1092 12% 311 61/2 165 511/46 1297 40% 1032 23156 592 15"1/46 399 183/16 462 275 125 351 159 Y Noryl®is a registered trademark of General Electric Company. Approvals • ® c0 . ale. 1048 Listed 864.4 2836 For additional approval information please contact the factory or visit our website at www.amesfirewater.com Capacity UUFM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. See literatue S-Cott-200/300 for gate valve flow characteristics * = Rated Flow ** = UL Tested Horizontal _. . ----Vertical N-Pattern kPa psi 21/2" 6~ * ** kPa psi * ** 96 14 83 12 ' N 83 12 - N 69 10 v 69 10 H 55 8 55 8 41 6 ..,....?-112-""=" .._::: 41 6 28 4 28 4 14 2 14 2 0 0 - 0 0 - . 0 50 100 150 200 250 300 350 gpm 0 300 600 900 1200 1500 gpm 0 190 380 570 760 950 1140 1330 fpm 0 1140 2280 3420 4560 5700 Ipm 15 15 fps 4.6 mps 4.6 mps kPa psi $° * * kPa psi r * * ** 83 12 - 83 12 N 69 10 H 69 10 � ■ 55 8 ' N 55 8 . 28 4 'v 41 6 28 4 14 2 14 2 0 0 0 0 - 0 100 200 300 400 500gpm 0 500 1000 1500 2000 2500 gpm 0 380 760 1140 1520 1900 Ipm 0 1900 3800 5700 7600 9500 Ipm 15 fps 15 fps 4.6 mps 4.6 mps kPa psi 4~ * ** kPa psi 10" * ** 165 24 - 83 12 138 20 N 69 10 N 110 16 H 55 8 H 83 12 41 6 --. v 55 8 28 4 28 4 14 2 0 0 - 0 0 0 100 200 300 400 500 600 700 800 gpm - - - 0 380 760 1140 1520 1900 2280 2660 3040 Ipm 0 500 1000 1500 2000 2500 3000 3500 gpm 15 fps 0 1900 3800 5700 7600 9500 11400 13300 Ipm r 4.6 mps fps mps IMPORTANT INQUIRE WITH GOVERNING AUTHORITIES FOR LOCAL INSTALLATION REQUIREMENTS For Technical Assistance Call Your Authorized Ames Agent. Telephone# Fax# HEADQUUrrens:Ames Fire and Waterworks 1427 North Market Blvd.,Suite#9,Sacramento,CA 95834 916 928-0123 916 928-9333 Edwards,Platt&Deely,Inc. 271 Royal Ave-,Hawthorne,NJ 07506 973 427-2898 973 427-4246 r„0 Edwards,Platt&Deely,Inc. 368 Wyandanch Ave.,North Babylon,NY 11703 631 253-0600 631 253-0303 Z w W.P.Haney Co.,Inc. 51 Norfolk Ave.,South Easton,MA 02375 508 238-2030 508 238-8353 RMI Glenfiield Bus.Ctr.,2535 Mechanicsville Tpk,Richmond,VA 23223 804 643-7355 804 643-7380 c The Joyce Agency,Inc. 8442 Alban Rd.,Springfield,VA 22150 703 866-3111 703 866-2332 2. Vernon Bitzer Associates,Inc. 980 Thomas Drive,Warminster,PA 18974 215 443-7500 215 443-7573 Q WMS Sales,Inc.(Main office) 9580 County Rd.,Clarence Center,NY 14032 716 741-9575 716 741-4810 Billingsley&Associates,Inc. 2728 Crestview Ave.,Kenner,LA 70062-4829 504 602-8100 504 602-8106 Billingsley&Associates,Inc. 418 Cheyenne Lane,Madison,MS 39110 601 856-7565 601 856-8390 Mid-America Marketing,Inc- 203 Industrial Or,Birmingham,AL 35211 205 879-3469 205 870-5027 5 N Mid-America Marketing,Inc. 1364 Foster Avenue,Nashville,TN 37210 615 259-9944 615 259-5111 o W Mid-America Marketing,Inc. 5466 Old Hwy.78,Memphis,TN 38118 901 795-0045 901 795-0394 0 Smith&Stevenson Co.,Inc. 4935 Chastain Ave.,Charlotte,NC 28217 704 525-3388 704 525-6749 Wager Company 702-B Industry Rd.,Longwood,FL 32750 407 834-4667 407 831-0091 Watts 2861-B Bankers Industrial Drive,Atlanta,GA 30360 770 209-3310 770 447-4583 t 2. HydroSource 8182 Chagrin Rd.,Chagrin Falls,OH 44023 440 247-9150 440 247-6719 :.- Mid-Continent Marketing Services Ltd. 1724 Armitage Ct,Addison,IL 60101 630 953-1211 630 953-1067 Z ° Soderholm 8 Associates,Inc. 7150 143rd Ave.N.W.,Anoka,MN 55303 763 427-9635 763 427-5665 0 Stickler 8 Associates 333 Math 121 St,Mitwaukee,WI 53226 414 771-0400 414 771-3607 Hugh M.Cunningham,Inc. 13755 Benchmark,Dallas,TX 75234 972 888-3808 972 888-3838 t ti Mack McClain&Associates 11132 South Towne Square,Suite 202,St Louis,MO 63123 314 894-8188 314 894-8388 c% Mack McClain 8 Associates,Inc. 1450 NE 69th Place,Ste.56 Ankeny,IA 50021 515 288-0184 515 288-504 o y Mack McClain 8 Associates,Inc. 15090 West 116th St,Olathe,KS 66062 913 339-6677 913 339-9518 (1)(,) OK!Sales,Inc. 2200 Blue Creek Dr.,Norman,OK 73026 405 360-6161 405 360-0092 Phoenix Marketing,Ltd. 2416 Candelaria N.E.,Albuquerque,NM 87107 505 883-7100 505 883-7101 Cisco 1738 Neville Street,Orange,CA 92865 714 921-9228 714 921-0442 Delco Sales,Inc. 111 Sand Island Access Rd.,Unit 1-10,Honolulu,HI 96819 808 842-7900 808 842-9625 t Hollabaugh Brothers 8 Associates 6915 South 194th St,Kent,WA 98032 253 867-5040 253 867-5055 y Hollabaugh Brothers 8 Associates 3028 S.E.17th Ave.,Portland,OR 97202 503 238-0313 503 235-2824 a P I R Sales,Inc. 3050 North San Marcos Place,Chandler,AZ 85225 480 892-6000 480 892-6096 5, Preferred Sales 31177 Wiegman Road,Hayward,CA 94544 510 487-9755 510 476-1595 Rep Masters,Inc. 6255 Dexter St,Commerce City,CO 80022 303 286-7575 303 286-7576 • Watts Industries(Canada)Inc. (Watts Regulator Co.Division) 5435 North Service Road,Burlington,Ontario 171.5117 905 332-4090 905 332-7068 D.C.Sales,Ltd. 10-6130 4th St S.E.,Calgary,Alberta T2H 2A6 403 253-6808 403 259-8331 D.C.Sales,Ltd. 11420142 Street,Edmonton,Alberta T5M 1V1 780 496-9495 780 496-9621 Hydro-Mechanical Sales,Ltd. 3700 Joseph Howe Dr.,Ste.1 Halifax,Nova Scotia B31.4H7 902 443-2274 902 443-2275 Hydro-Mechanical Sales,Ltd. 297 Colishaw St,Ste.7(shipping)Moncton,New Brunswick E1C 9R2 506 859-1107 506 859-2424 (13 Hydro-Mechanical Sales,Ltd. 85 Toll Rd.,St Philips,Newfoundland A1B 3W 709 895-0090 709 895-0091 C Le Groupe B.G.T.,Inc. 23 du Buisson,Pont Rouge,Quebec G3H 1X9 418 832-2800 418 873-2505 U Le Groupe B.G.T.,Inc. 86 des Enterprises#208,Boisbriand,Quebec J7G 2T3 450 434-9010 450 434-9848 Mar-Win Agencies,Ltd. 1333 Cifton St,lAfinnipeg,Manitoba R3E 2V1 204 775-8194 204 786-8016 Northern Mechanical Sales P.O.Box 280(mating)163 Pine St(shipping),Garson,Ontario P3L 1S6 705 693-2715 705 693-4394 Palser Enterprises,Ltd. 1885 Blue Heron Dr.,#4,London,Ontario N6H 51.9 519 471-9382 519 471-1049 RAM Mechanical Marketing 1301 Winnipeg St,Regina,Saskatchewan S4R 1K2 306 525-1986 306 525-0809 RAM Mechanical Marketing 510 Ave.M South,Saskatoon,Saskatchewan S7K 2K9 306 244-6622 306 244-0807 0423 Walmar Mechanical Sales 24 Gurdwara Rd.,Nepean,Ontario K2E 885 613 225-9774 613 225-0673 . A - A M E S 1S09001 FIRE&WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com c.ERAFIED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-C300/C300N 0306 ©Ames Co.2003 Printed in U.S.A. _ QUICK RESPONSE ja ; RECE�OMATIC SPRINKLERS FIRE SPRINKLER GL SERIES CORPORATION APR 2 3 2009 DRY TYPE CITY OFTIG� BUILDING DIVISION PENDENT DESCRIPTION AND OPERATION RECESSED PENDENT The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for , . i... use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm ' I frangible glass ampule as the thermosensitive element This provides sprinkler - operation approximately six times faster than ordinary sprinklers- At the ampule's e rated temperature,the sprinkler opens releasing the bulb seat,causing the inner tube assembly to move,allowing the spring assembly to pivot alongside the inner tube. At e,- this time water flows through the sprinkler and is distributed by the deflector in an ..---,-,77-77, :,'_ approved discharge pattern. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray I sprinklers are specified but offers the additional feature of greatly increased safety to ,CIF life. Quick Response Sprinklers should be used advisedly and under the direction of ` J approving authorities having jurisdiction. The heart of Globe's Model GL Series sprinkler proven actuating assembly is a QUICK RESPONSE hermetically sealed frangible glass ampule that contains a precisely measured amount SURFACE SLEEVE of fluid. When heat is absorbed,the liquid within the bulb expands increasing the MOUNT &SKIRT internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter- This results in water discharge which is distributed in an approved pattern. Ii TECHNICAL DATA III • See reverse side for Approvals and Specifications. " • Temperature Ratings - 135°F (57°C), 155°F (68°C) 175°F (79°C) 200°F (93°C),286°F (I4I°C). - • Water Working Pressure Rating- 175 psi (12 Bars). f,..-4' s'.--- • Factory tested hydrostatically to 500 psi (34 Bars). — I A. • Maximum low temperature glass bulb rating is -67°F (-55°C). • Frame - bronze • Deflector- brass • Screw - brass I•, �T At • Bulb seat - brass • Spring - teflon coated nickel alloy 1 • Retainer- brass • Pin - stainless steel • Torsion spring - stainless steel QUICK RESPONSE • Bulb -glass with alcohol based solution, 3mm • Orifice insert- brass • 3/4" NPT or I" NPT • Outer tube-galvanized steel pipe EXTENDED RECESSED • Inner tube - stainless steel •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A.MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY i 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH I 286°F 141°C BLUE 225°F 107°C 4077 AIRPARK DRIVE,STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 OCTOBER 2005 A-55 BULLETIN GL5635, REV.#I0 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE PENDENT RECESSED PENDENT S PECIFICATIONS NOMINAL"K" FACTOR THREAD SIZE LENGTH' FINISHES Factory Bronze 5.6 (80 metric) 314"or I' NPT 'Satin Chrome Variable Bright Chrome to 48" White Polyester' 8.1 (116 metric) I" NPT Black Polyester' 'Lead Coated NOTE METRIC CONVERSIONS ARE APPROXIMATE. FINISHES AVAILABLE ON SPECIAL ORDER. 'cULus LISTED FOR UP TO A 48""A"DIMENSION. APPROVALS PC-U.L LISTED OLY ESTER MUST BEOSPECIFIED ON ORDER. STYLE SIN K FACTOR THREAD 135°F 155°F 175°F 200°F 286°F cULus NYC-DOB MODEL SIZE 57°C 68°C 79°C 93°C 141°C MEA I0I-92-E GL5635 5.6 1"NPT X X X X X X X PENDENT GL5636 5.6 3/4"NPT X X X X X X X G18135 8.1 I'NPT X X X X X X X GL5635 5.6 1"NPT X X X X X X X RECESSED GL5636 5.6 3/4"NPT X X X X X X X PENDENT ' GL.8135 8.1 1"NPT X X X X X X X >LISTED FOR ALL HAZARDS. CROSS SECTIONS IMPORTANT INSTALLATION DATA -, .••,.: nom. �•'• »1T .t Globe GL Series Dry Pendent sprinklers should be in- _ _ stalled in accordance with the requirements set forth in -`j S i P ;-j C" NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, ..i.. 4:aw the proper sprinkler head wrench may be used with extreme ;,.." ///// I////.i '; „� . v.° care forlengthsuptoapproximately 18". Excessiveforcemay ,T _ Ott. distort the frame thus destroying the unit. /////I '����� For further important installation data,please refer to our Dry Sprinkler Caution Sheet Ali a k•i ORDERING INFORMATION �/:.for. `t EXTENDED PENDENT PENDENT SPECIFY •Quantity • Model Number • Style • Orifice r ��— N9 a '',7:----".: -a •Temperature • Finishes desired lma ,� m Q a .�. :-, i r •Quantity-Wrenches-P/N 333010 r •Quantity-Recessed Wrenches-P/N 337014 •Quantity-Protective Caps-P/N 327109-CAP(Friction -.:1'..74:74 Fit Recessed) " •Escutcheons desired -:% 111=1 '—� •"A"Dimension-Distance from face of fitting to the � II��/�, _ finished ceiling line regardless of escutcheon used TIO MR at_ . : `�."o°� a �:� GLOBE®PRODUCT WARRANTY• Globe agrees to repair or replace any of its own manufac- RECESSED PENDENT SLEEVE&SKIRT PENDENT cured products found to be defective in material or workman- ship for a period of one year from date of shipment. LoBE For specific details io of our warranty please refer to Price Art List Terms and Conditions of Sale(Our Price List). WV 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FIRE SPRINKLER CORPORATION 989-846-4583 FAX 989-846-9231 1-800-248-0278 www,globesprinkler.com OCTOBER 2005 PRINTED U.SA. BULLETIN GL5635, REV.#I0 tLjCD I Fire & Building ECE r. Products APR 2 2Q0 ENTRAL CITY OF GA ustomer Service/Sales: Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 ��ei k362-0700/(800)523-6512 R[TR DINC ax:(215)362-5385 Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General mospheres. Although corrosion resis- taut coated sprinklers have passed the standard corrosion tests of the appli Description cable approval agencies,the testing is ' not representative of all possible cor- The Series TY-FRB, 2.8,4.2,5.6,and rosive atmospheres. Consequently, it 8.0 K-factor, Upright and Pendent is recommended that the end user be -- Sprinklers described in this data sheet consulted with respect to the suitability are quick response - standard cover- of these coatings for any given corro- -- age,decorative 3 mm glass bulb type sive environment.The effects of ambi- spray sprinklers designed for use in ent temperature, concentration of — -- - light or ordinary hazard, commercial chemicals, and gas/chemical velocity, =';- occupancies such as banks, hotels, should be considered, as a minimum, - = shopping malls, etc. along with the corrosive nature of the , The recessed version of the Series chemical to which the sprinklers will be TY-FRB Pendent Sprinkler, where ap- exposed. plicable, is intended for use in areas An intermediate level versions of the _ with a finished ceiling.It uses either a Series TY-FRB Pendent Sprinklers are -_ two-piece Style 10 (1/2 inch NPT) or detailed in Technical Data Sheet %,_ Style 40(3/4 inch NPT) Recessed Es- TFP356,and Sprinkler Guards are de- cutcheon with 1/2 inch (12,7 mm) of tailed in Technical Data Sheet TFP780 V recessed adjustment or up to 3/4 inch (19,1 mm)of total adjustment from the WARNINGS "11";-` = 4 flush pendent position, or a two-piece The Series TY-FRB Sprinklers de- Style 20(1/2 inch NPT)or Style 30(3/4 scribed herein must be installed and inch NPT) Recessed Escutcheon with maintained in compliance with this 1/4 inch (6,4 mm) of recessed adjust- document,as well as with the applica- ment or up to 1/2 inch (12,7 mm) of ble standards of the National Fire Pro- total adjustment from the flush pen- tection Association, in addition to the TY3231 - Pendent 5.6K,1/2"NPT dent position.The adjustment provided standards of any other authorities hay- TY4131 Upright 8.0K,3/4"NPT by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may TY4231 Pendent 8K,3/4"NPT the accuracy to which the fixed pipe impair the performance of these de- r drops to the sprinklers must be cut. vices. Technical Corrosion resistant coatings, where The owner is responsible for maintain- Data applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler Approvals tained when exposed to corrosive at- manufacturer should be contacted UL and C-UL Listed. with any questions. FM, LPCB,and NYC Approved. (Refer to Table A for complete approval IMPORTANT information including corrosion resis- Always refer to Technical Data tant status.) Sheet TFP700 for the "INSTALLER Model/Sprinkler WARNING' that provides cautions Maximum Working Pressure with respect to handling and instal- Identification 175 psi (12,1 bar) lation of sprinkler systems and com- Discharge Coefficient ponents. Improper handling and in- Numbers K=2.8 GPM/psi1/2(40,3 LPM/barl12) stallation can permanently damage K=4.2 GPM/psi1/2(60,5 LPM/bare) a sprinkler system or its compo- TY1131 - Upright 2.8K,1/2"NPT K=5.6 GPM/psi1/2(80,6 LPM/bar1/2) nents and cause the sprinkler to fail TY1231 - Pendent 2.8K,1/2"NPT K=8.0 GPM/psi1/2(115,2 LPMIbarlr2) to operate in a fire situation or cause TY2131 - Upright 4.2K,1/2"NPT Temperature Ratings it to operate prematurely. TY2231 - Pendent 4.2K,1/2"NPT Refer to Table A and B TY3131 - Upright 5.6K,1/2"NPT Page 1 of 8 JULY, 2004 TFP171 Page 2 of 8 TFP171 ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED # SURFACE 1Y2 MAKE-IN ESCUTCHEON SSU NPT DEFLECTOR MM 2-1/4" 1i1';�� 7/16" !�� 5 (11,1 mm) 4 (57,2 mm) �I ��P�- 1II NOMINAL f `�11� MAKE-IN , 2 19/16" I `�� i 23/16" 1 3 (39,7 mm) jii;!i WRENCH (55,6 mm) ,4; 1 II FLATS 1 _° s`/ • SSP DEFLECTOR* - 2-7/8"(73,0 mm)DIA. 1/2"NPT** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression 7-Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR ffT%. 6* I 'ii77re 7�7n��: ( c�,i7T1,lok �—2-3/16" 1�r, � (11 1 nxft) 5(55,6 mm) A�� ��_� I NOMINAL I ` 4 J� i L 7I1-1/2" I �� 2-3/16" 2 (38,1 mm) "III, lilt WRENCH i (55.6 mm) a y 1 -- ■_ -•• -- ._ FLATS __ 1 1 I 3 6 f 1 SSP DEFLECTOR* - 2-7/8"(73,0 mm)DIA. 1/2"NPT** f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT Y m Finishes Bulb Glass — Sprinkler:Refer to Table A and B Compression Screw Bronze peration a Recessed Escutcheon:White Coated, Deflector. . . . . . . Copper/Bronze v . Chrome Plated,or Brass Plated Bushing(K=2.8) Bronze The glass Bulb contains a fluid which m expands when exposed to heat.When y Physical Characteristics the rated temperature is reached, the 5 cp Frame Bronze fluid expands sufficiently to shatter the cc Button Brass/Copper glass Bulb, allowing the sprinkler to E' . Sealing Assembly activate and water to flow. a Beryllium Nickel w/Teflont ci TFP171 Page 3 of 8 " ESCUTCHEON 7/16"(11,1 mm) STYLE 10 or 20 PLATE SEATING „** NOMINAL RECESSED ; SURFACE 1/2 MAKE-IN ESCUTCHEON SSU NPT 1 DEFLECTOR i =---t iN 7/16" ter 5 2-3/16" 'ir� (11,1 mm) (55,6 mm) IT�� ��Nr- I NOMINAL 1111,I 4 i L 1�1 M MIENIN 1-1/2" (38,1 mm) 1110 III, 1 2-3/16" ' 2 WRETCH 1 (55.6 mm) 3 , i ._ 14 A SSP DEFLECTOR* - 2-7/8"(73,0 mm)DIA. y 1/2"NPT** 1 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 -Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2"(12,7 mm) STYLE 30 or 40 PLATE SEATING „** NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR 6*■i it r 'u�1 r �` Y 1/2” Si 5 2-5/16" } liL_MI (12,7 mm) 11 (58,7 mm) + IT-� -J. NC.- I NOMINAL i 4 ��1, MAKE-IN `� • 1-9/16" I r= 2-1/4" Mi 2(39,7 mm) IWRENCH (57,2 mm) 3 . . FLATS SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. --+ 3/4"NPT** t PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1-Frame 3-Sealing 4-Bulb 6-Deflector * Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT Listing is based on the requirements of Design NFPA 13, and FM Approval is based Installation on the requirements of FM's Loss Pre- Criteria vention Data Sheets ). Only the Style The Series TY-FRB Sprinklers must be 10, 20, 30, or 40 Recessed Escutch- installed in accordance with the follow- - The Series TY-FRB Pendent and Up- eon, as applicable, is to be used for ing instructions: right Sprinklers are intended for fire recessed pendent installations. protection systems designed in ac- NOTES cordance with the standard installation Do not install any bulb type sprinkler if • rules recognized by the applicable the bulb is cracked or there is a loss of Listing or Approval agency (e.g., UL liquid from the bulb. With the sprinkler Page 4 of 8 TFP171 _ SPRINKLER FINISH(See Note 7) inch NPT sprinkler joint should be ob- K TYPE TEMP. BULB NATURAL CHROME WHITE"' (13,4d with a torque of a to m o.fbs. LIQUID BRASS PLATED POLYESTER f t3,4 to ,7,8 )of A maximum to be of 30 ft.lbs.(40,7 Nm)of torque is to be used to install sprinklers with 3/4 NPT con- 135"F/57°C Orange nections. Higher levels of torque may PENDENT 155°F/68°C Red distort the sprinkler inlet and cause (TY1231) 1.2,3.5 leakage or impairment of the sprinkler. and 175°F/79°C Yellow UPRIGHT Do not attempt to make-up for insuffi- UPRIGHT Green cient adjustment in the escutcheon 2.8 (TY1131) 286°F/141°C Blue plate by under- or over-tightening the 1/2" sprinkler. Readjust the position of the NPT 135°F/57°C Orange sprinkler fitting to suit. RECESSED 155°F/68°C Red The Series TY-FRB Pendent and Up- PENDENT right Sprinklers must be installed in (fY1231)' 175"F179°C Yellow Figure 5 accordance with the following instruc- Figure Green 1,2,5 Lions. 135°F/57°C Orange Step 1. Pendent sprinklers are to be RECESSED 155°F/68°C Red installed in the pendent position, and PENDENT upright sprinklers are to be installed in (1-Y1231)" 175°F/79°C Yellow the upright position. Figure 6 200°F/93°C Green Step 2. With pipe thread sealant ap- 135°F/57°C Orange plied to the pipe threads,hand tighten PENDENT the sprinkler into the sprinkler fitting. (TY2231) 155°F/68°C Red Step 3. Tighten the sprinkler into the and 175°F/79°C Yellow sprinkler fitting using only the W-Type UPRIGHT 200°F/93°C Green 6 Sprinkler Wrench (Ref. Figure 13). (TY2131) With reference to Figures 1, 2, 3, and 4.2 286°F/141°C Blue 2 4,the W-Type 6 Sprinkler Wrench is to 1/2" be applied to the sprinkler wrench NPT 135°F/57°C Orange flats. RECESSED 155°F/68"C Red PENDENT (Ty2231)• 175°F/79°C Yellow The Series TY-FRB Recessed Pen- . Figure 7 200°F/93°C Green dent Sprinklers must be installed in accordance with the following instruc- 135"F/57°C Orange Lions. RECESSED 155°F/68°C Red Step A. After installing the Style 10. • PENDENT 20, 30,or 40 Mounting Plate,as appli- (TY2231)•• 175"F179°C Yellow cable, over the sprinkler threads and Figure 8 200°F/93°C Green with pipe thread sealant applied to the pipe threads, hand tighten the sprin- NOTES: kler into the sprinkler fitting. 1.Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers. Step B.Tighten the sprinkler into the 2.Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL)as Quick Response sprinkler fitting using only the W-Type Sprinklers. 3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprin- klers. Figure 14).With reference to Figure 1, 5.Approved by the City of New York under MEA 354-01-E. 2, 3, and 4, the W-Type 7 Recessed 7.Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprin- Sprinkler Wrench is to be applied to klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. the sprinkler wrench flats. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Step C. After the ceiling has been in- Recessed Escutcheon,as applicable. stalled or the finish coat has been ap- "Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment plied,slide on the Style 10,20, 30,or Recessed Escutcheon,as applicable. Frame and Deflector only.Listings and approvals apply to color(Special Order). 40 Closure over the Series TY-FRB N/A:Not Available Sprinkler and push the Closure over the Mounting Plate until its flange TABLE A comes in contact with the ceiling. LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS held horizontally, a small air bubble A leak tight 1/2 inch NPT sprinkler joint should be present. The diameter of the should be obtained with a torque of 7 air bubble is approximately 1/16 inch to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- (1,6 mm) for the 135F/57°C to 3/32 mum of 21 ft. lbs. (28,5 Nm)of torque inch (2,4 mm) for the 286°F/141°C may be used to install sprinklers with temperature ratings. 1/2 NPT connections. A leak tight 3/4 TFP171 Page 5 of 8 SPRINKLER FINISH(See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE"` LEAD LIQUID BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT 155°F/68°C Red (TY3231) 1,2,3,4,5,6,7 1,2,3.5 and 175°F/79°C Yellow UPRIGHT 200°F/93°C Green 5.6 (TY3131) 286°F/141°C Blue 1/2" NPT 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1,2,4,5 N/A (TY3231)" 175°F/79°C Yellow Figure 9 20OF/93°C Green 135°F/57°C Orange RECESSED 155'F/68°C Red PENDENT 1,2,3,4,5 1,2,4,5 N/A (TY3231)" 175Fi79°C Yellow Figure 10 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY4231) 1.2.5 and 175°F/79°C Yellow 1,2,3,4,5,6,7 UPRIGHT 20O'F/93°C Green 8.0 (TY4131) 286"F/141°C Blue 3/4" NPT 135°F/57°C Green RECESSED 155°F/68°C Orange PENDENT 1,2,4,5 N/A (TY4231)' 175°F/79°C Red Figure 11 200"F/93°C Yellow 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 1,2,3,4,5 N/A (TY4231)" 175°F/79°C Yellow Figure 12 200F/93°C Green NOTES: 1.Listed by Underwriters Laboratories,Inc.(UL)as Quick Response Sprinklers. 2.Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL)as Quick Response Sprinklers. 3.Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4.Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers;however,the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5.Approved by the City of New York under MEA 354-01-E. 6.VdS Approved(For details contact Tyco Fire&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377). 7.Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8.Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers.Where Lead Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. • Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. • Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 8 TFPI 71 2-7/8'DIA_ 2-7/8'DIA. 5/8±1/4" (73,0 mm) 314'(19,1 mm) 1/2+1/8' (73.0 mm) 1/2'(12,7 mm) (15,9±6,4 mm) 2-1/4'DIA. 1/4'(6,4 mm) (12,7±3,2 mm) 2-1/4'DIA. 1/4'(6,4 mm) FACE OF (57,2 mm) 1 MOUNTING (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8' 1/8' (3,2 mm) (3,2 mm) JI .I �� ii1 �� ".f 1 - w j- MOUNTING 1111 MOUNTING �. SURFACE �. SURFACE ,/!-��, } ,/i'1'1.N. CLOSURE SERIES 1-5/16'(33,3 mm)J CLOSURE SERIES 1-5/16'(33,3 mm)( TY-FRB 13/16'(20,6 mm) TY-FRB 1-1/16'(27,0 mm) FIGURE 5 FIGURE 6 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 1NCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8'D1k 2-7/8'DIA. 5/8±1/4' (73,0 mm) 3/4'(19,1 mm) 1/2±1/8' (73,0 mm) 1/2'(12,7 mm) (15,9±6,4 mm) 2-1/4'DIA. 1/4'(6,4 mm) (12,7±3,2 mm) 2-1/4'DIA. 1/4'(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8' 1/8' MSZ-lia. (3,2 mm) rT (3,2 mm) 711M-Mil 49' i ■ //A Milli irAl___ 'li t t \ Ilig r 1. t ' MOUNTING �' MOUNTING ■ I SURFACE . SURFACE - .. CLOSURE SERIES 1-1/4'(31,8 mm) CLOSURE SERIES 1-1/4'(31,8 mm) TY-FRB 3/4'(19,1 mm) TY-FRB 1'(25,4 mm) FIGURE 7 FIGURE 8 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH NPT Care and used to cover a clearance hole, may and after installation. Sprinklers dam- delay the time to sprinkler operation in aged by dropping, striking, wrench a fire situation. twist/slippage, or the like, must be re- Maintenance Sprinklers that are found to be leaking placed.Also,replace any sprinkler that or exhibiting visible signs of corrosion has a cracked bulb or that has lost The Series TY-FRB Sprinklers must be g g liquid from its bulb. (Ref. Installation maintained and serviced in accord- must be replaced. Section). ance with the following instructions: Automatic sprinklers must never be painted, plated, coated or otherwise Frequent visual inspections are rec- NOTES altered after leaving the factory-Modi- ommended to be initially performed for Before closing a fire protection system tied sprinklers must be replaced. corrosion resistant coated sprinklers, main control valve for maintenance Sprinklers that have been exposed to after the installation has been com work on the fire protection system that corrosive products of combustion, but pleted,to verify the integrity of the cor- it controls,permission to shut down the have not operated,should be replaced rosion resistant coating. Thereafter, - affected fire protection system must be if they cannot be completely cleaned annual inspections per NFPA 25 obtained from the proper authorities by wiping the sprinkler with a cloth or should suffice;however, instead of in and all personnel who maybe affected by brushing it with a soil bristle brush. specting from the floor level,a random by this action must be notified. sampling of close-up visual inspec- - Care must be exercised to avoid dam- tions should be made, so as to better Absence of an escutcheon, which is age to the sprinklers - before, during, determine the exact sprinkler condi- TFP171 Page 7 of 8 2-7/8'DIA _ 2-7/8'DIA. _ 5/8±1/4' (73,0 mm) 3/4'(19,1 mm) 1/2±1/8- (73,0 mm) 1/2'(12,7 mm) (15,9±6,4 mm) 1/4'(6,4 mm) (12,7±3,2 mm) 2-1/4'DIA. 1/4'(6,4 mm) 2-N4'DIA FACE OF (57,2 mm) 1 MOUNTING FACE OF (57,2 mm) 1 MOUNTING SPRINKLER I PLATE SPRINKLER I PLATE FITTING FITTING 1/8- 1/B• •a (3,2 mm) is (3,2 mm) riiM _-=,--111111 w. I ■ - f MOUNTING MOUNTING II I SURFACE �,�' SURFACE SERIES 1-1/4'(31,8 mm) SERIES 1-1/4'(31,8 mm) CLOSURE TY-FRB CLOSURE iY-FHH 3/4•(19,1 mm) 1'(25,4 mm) FIGURE 9 FIGURE 10 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT 2-78'DIA. 2-7/8'DIA 5/8±114' (73,0 mm) 3/4'(19,1 mm) 1/2f18• (73,0 mm) 1/2'(12,7 mm) (15,9±6,4 mm) 2-1/4'DIA 1 1/4'(6,4 mm) (12,7±3,2 mm) 2-1/4'DIA 1/4'(6,4 mm) (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING FACE OF SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8' I t/8• El M II (3,2 mm) _ �+ (3,2 mm) 'till / �(I /ice , j MOUNTING II, MOUNTING fl, �, I SURFACE �: SURFACE '. CLOSURE SERIES 1-5/16'(33,3 mm) CLOSURE SERIES 1-5/16'(33.3 mm) ` TY-FRB 13/16'(20,6 mm) TY-FRB 1-1/16'(27,0 mm) FIGURE 11 FIGURE 12 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT 8.0 K-FACTOR,3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may /11PLENCH WRENCH be affected by the corrosive conditions RECESS present. , RECESS 1# The owner is responsible for the in- ND'A'USED FOR ��their re testing, and maintenance of /2'NPT MODELS} their fire protection system and de- ''°' vices in compliance with this docu- ment, as well as with the applicable ..r standards of the National Fire Protec- WRENCH RECESS (END'B'USED FOR PUSH WRENCH tion Association (e.g., NFPA 25), in IN TO ENSURE addition to the standards of any other 3/4"NPT MODELS) ENGAGEMENT authorities having jurisdiction.The in- WITH SPRINKLER . stalling contractor or sprinkler manu- FIGURE 13 WRENCHING AREA facturer should be contacted relative to W-TYPE 6 SPRINKLER any questions. WRENCH It is recommended that automatic FIGURE 14 sprinkler systems be inspected, local requirements and/or national W-TYPE 7 RECESSED . tested, and maintained by a qualified codes. SPRINKLER WRENCH Inspection Service in accordance with Page 8 of 8 TFP171 P/N 57 - XXX - X - XXX 1 TEMPERATURE MODEUSIN RATING SPRINKLER 330 2.8K UPRIGHT(1/2"NPT) TY1131 135 135°F/57°C 331 2.8K PENDENT(1/2"NPT) TY1231 1 NATURAL BRASS 155 155°F/68°C 340 4.2K UPRIGHT (1/2"NPT) TY2131 4 WHITE POLYESTER 175 175°F/79°C 341 4.2K PENDENT(1/2"NPT) TY2231 3 WHITE(RAL9010)' 200 200°F/93°C 370 5.6K UPRIGHT(1/2"NPT) TY3131 9 CHROME PLATED 286 286°F/141°C 371 5.6K PENDENT(1/2'NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT(3/4"NPT) TY4131 391 8.0K PENDENT(3/4"NPT) TY4231 -Eastern Hemisphere sales Only TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS ORY, FOR INCIDENTAL, INDIRECT, Recessed Escutcheon: Limited SPECIAL OR CONSEQUENTIAL Specify: Style (specify) Recessed Es- DAMAGES, INCLUDING BUT NOT cutcheon with (specify finish), P/N Warranty LIMITED TO LABOR CHARGES, RE- (specify). GARDLESS OF WHETHER TYCO Products manufactured by Tyco Fire FIRE PRODUCTS WAS INFORMED 1/2' (15 mm) Products are warranted solely to the ABOUT THE POSSIBILITY OF SUCH Style 10 . original Buyer for ten (10) years DAMAGES, AND IN NO EVENT Chrome Plated P/N56-701-9-010 against defects in material and work- SHALL TYCO FIRE PRODUCTS' LI- White Coated P/N 56-701-4-010 manship when paid for and properly ABILITY EXCEED AN AMOUNT Br Brass Pllated ated • P/N 56-701-3-010 P/N 56-701-2-010 installed and maintained under normal EQUAL TO THE SALES PRICE. use and service.This warranty will ex- THE FOREGOING WARRANTY IS 1/2' (15 mm) pire ten (10) years from date of ship- Style 20 ment by Tyco Fire Products. No war- MADE IN LIEU OF ANY AND ALL Chrome Plated P/N 56-705-9-010 ranty is given for products or OTHER WARRANTIES EXPRESS OR White Coated P/N 56-705-4-010 components manufactured by comps IMPL/ED.INCLUDING WARRANTIES White RAL9010• P/N 56-705-3-010 Hies not affiliated by ownership with OF MERCHANTABILITY AND FIT- Brass Plated P/N 56-705-2-010 Tyco Fire Products or for products and NESS FOR A PARTICULAR PUR- 3r4• (20 mm) components which have been subject POSE, Style 30 to misuse,improper installation,corro- Chrome Plated P/N 56-705-9-011 sion,or which have not been installed, White Coated P/N 56-705-4-011 maintained,modified or repaired in ac- while Plated 0• P/N 56-705-3-011 cordance with applicable Standards of ordering Brass Plated P/N 56-705-2-011 the National Fire Protection Associa- Procedure 3/4" (20 mm) Lion,and/or the standards of any other Style 40 Authorities Having Jurisdiction. Mate- Bfxittookpguit focal distributor for avail- Chrome Plated P/N 56-700-9-010 rials found by Tyco Fire Products to be ab(f�y,indicate the White Coated P/N 56-700-4-010 defective shall be either repaired or lull product White HAL9010• P/N 56-700-3-010 replaced, at Tyco Fire Products' sole name.Refer to Brass Plated P/N 56-700-2-010 the Price List for option.Tyco Fire Products neither as- complete listing •Eastern Hemisphere sales only sumes, nor authorizes any person to of Part Numbers. assume for it, any other obligation in Sprinkler Wrench: connection with the sale of products or Sprinkler Assemblies with NPT Specify: W-Type 6 Sprinkler Wrench, parts of products. Tyco Fire Products Thread Connections: P/N 56-000-6-387. shall not be responsible for sprinkler Specify: (Specify Model/SIN), Quick system design errors or inaccurate or Response, (specify K-factor), (specify Specify: W Type 7 Sprinkler Wrench, incomplete information supplied by temperature rating), Series TY-FRB P/N 56-850-4-001. Buyer or Buyer's representatives. (specify Pendent or Upright)Sprinkler IN NO EVENT SHALL TYCO FIRE with(specify type of finish or coating), PRODUCTS BE LIABLE, IN CON- P/N(specify from Table C). TRACT,TORT,STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 tqco I Fire & Building Products rapid response" HOME FIRE SPRINKLER SYSTEM Technical Services:TeL (800)381-9312/Fax:(800)791-5500CEI 1rD Series LFII Residential APR 2 3 20009 Pendent Sprinklers CITY OFTIGARD 4.9 K-factor BUILDING DIVISION adjustment or up to 1/2 inch(12,7 mm) General of total adjustment from the flush ceil- ing position. The adjustment provided Description by the Recessed Escutcheon reduces the accuracy to which the pipe nipples The Series LFII (TY2234) Residential to the sprinklers must be cut. Pendent Sprinklers are decorative, fast response, frangible bulb sprin The Series LFII (TY2234) has been klers designed for use in residential designed with heat sensitivity and occupancies such as homes, apart- water distribution characteristics ments,dormitories, and hotels. When Proven to help in the control of residen aesthetics and optimized flow charac- tial fires and to improve the chance for % I. teristics are the major consideration, occupants to escape or be evacuated. ', t . the Series LFII(TY223.4)should be the first choice. WARNINGS -- .. `` The Series LFII are to be used in wet The Series LFII (TY2234)Residential pipe residential sprinkler systems for Pendent Sprinklers described herein one-and two-family dwellings and mo- must be installed and maintained in • bile homes per NFPA 13D; wet pipe compliance with this document, as ;,. residential sprinkler systems for resi- well as with the applicable standards jm ' • dential occupancies up to and includ- of the National Fire Protection Asso- -{ ing four stories in height per NFPA ciation, in addition to the standards of ;ate - 13R;or wet pipe sprinkler systems for any other authorities having jurisdic- I F"' the residential portions of any occu- tion. Failure to do so may impair the 4 pancy per NFPA 13. performance of these devices. ; The Series LFII (TY2234) has a 4.9 The owner is responsible for maintain %- . 1r' (70,6) K-factor that provides the re- ing their fire protection system and de- <'1`� quired residential flow rates at reduced vices in proper operating condition. pressures,enabling smaller pipe sizes The installing contractor or sprinkler r and water supply requirements. manufacturer should be contacted The recessed version of the Series with any questions. '...*„„ LFII (TY2234) is intended for use in -+ c isi >` areas with finished ceilings.It employs Sprinkler/Nlodel a two-piece Style 20 Recessed Es- cutcheon. The Recessed Escutcheon Identification provides 1/4 inch(6,4 mm)of recessed Number SIN TY2234 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- - stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause - it to operate prematurely. Page 1 of 8 JANUARY, 2006 TFP400 Page 2 of 8 TFP400 - Minimum Flow(b)and Minimum Flow(b)and Minimum Flow(b)and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area tat Ft. (Max.2 Inch Rise (Greater Than 2 Inch Rise (Greater Than 4 Inch Rise Ft x Ft. (m) for 12 Inch Run) Up To Max.4 Inch Rise for 12 Inch Run) Up To Max.8 Inch Rise for 12 Inch Run) (m x m) 155°F/68°C or 155°F/68°C 175°F179°C 155°F/68°C 175°F/79°C 175°F/79°C 12 x 12 12 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (3,7 x 3.7) (3,7) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 14 x 14 14 13 GPM(49,2 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (4,3 x 4,3) (4,3) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 16 x 16 16 13 GPM(492 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) 13 GPM(49,2 LPM) 17 GPM(64,3 LPM) (4,9 x 4,9) (4,9) 7.0 psi(0,48 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 7.0 psi(0,48 bar) 12.0 psi(0,83 bar) 18 x 18 18 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) 17 GPM(64,3 LPM) (5,5 x 5,5) (5,5) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 12.0 psi(0,83 bar) 20 x 20 20 20 GPM(75,7 LPM) 20 GPM(75,7 LPM) 20 GPM(75,7 LPM) 21 GPM(79,5 LPM) 22 GPM(83,3 LPM) (6.1 x6,1) (6,1) 16.7 psi(1,15 bar) 16.7 psi(1,15 bar) 16.7 psi(1,15 bar) 18.4 psi(1,27 bar) 20.2 psi(1,39 bar) (a) For coverage area dimensions less than or between those indicated,it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII(TY2234) RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS Technical Design mum allowable a coverage and the maxi mum allowable covers a area. Data Criteria • A minimum discharge of 0.1 gpm/sq. ft.over the"design area"comprised Approvals: The Series LFII (TY2234) Residential of the four most hydraulically de- • UL and C-UL Listed. NYC Approved Pendent Sprinklers are UL and C-UL mending sprinklers for the actual under MEA 44-03-E. Listed for installation in accordance coverage areas being protected by - Maximum Working Pressure: with the following criteria. the four sprinklers. 175 psi(12,1 bar) Obstruction To Water Distribution. NOTE Locations of sprinklers are to be in Discharge Coefficient: When conditions exist that are outside accordance with the obstruction rules K =4.9 GPM/psi1/2(70,6 LPM/bar712) the scope of the provided criteria,refer of NFPA 13 for residential sprinklers. Temperature Rating: to the Residential Sprinkler Design p F 155°Fl68°C or 175F179°C Guide TFP490 for the manufacturer's Operational Sensitivity. recommendations that may be accept- • For"Horizontal Ceilings" (maximum Finishes: able to the local Authority having Juris- 2 inch rise for 12 inch run),the sprin- White Polyester Coated, diction. klers are to be installed with a deflec- Chrome Plated,or Natural Brass tor to ceilin distance of 1 318 to 4 System Type. Only wet pipe systems 9 Physical Characteristics: may be utilized. inches or in the recessed position using only the Style 20 Recessed Frame Brass Hydraulic Design. The minimum re- Escutcheon as shown in Figure 2. Button Bronze quired sprinkler flow rate for systems Sealing Assembly designed to NFPA 13D or NFPA 13R NOTES Beryllium Nickel w/Teflont are given in Table A as a function of The "Beam Ceiling Design Criteria" Bulb 3 mm dia. Glass temperature rating and the maximum section starting on Page 4 permits de- Compression Screw Bronze allowable coverage areas. The sprin- Hector to ceiling distances up to 15-3/4 Deflector Bronze kler flow rate is the minimum required inches Ejection Spring . . . . Stainless Steel discharge from each of the total tDuPont Registered Trademark number of "design sprinklers" as So as to help avoid obstructions to specified in NFPA 13D or NFPA 13R. water distribution, a maximum 12 inch Operation For systems designed to NFPA 13,the deflector-to-ceiling distance is permit- ted for NFPA 130 and NFPA 13Rappli- number of design sprinklers is to be cations where the sprinklers are located The glass Bulb contains a fluid that the four most hydraulically demanding in closets expands when exposed to heat.When sprinklers.The minimum required dis- the rated temperature is reached, the charge from each of the four sprinklers • For "Sloped Ceilings" (greater than - fluid expands sufficiently to shatter the is to be the greater of the following: 2 inch rise up to 8 inch rise for 12 glass Bulb allowing the sprinkler to inch run), the sprinklers are to be activate and flow water. • The flow rates given in Table A for installed with a deflector to ceiling NFPA 13D and 13R as a function of TFP400 Page 3 of 8 7116"(11,1 mm) 1r ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 2-7/8"DIA. y 1 Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 3 Seating Assembly 1 4 - Bulb A 0 A 5- Compression 2 °"" �_ Screw At } 2-1/4" '■�L�6 - Deflector' 3 '� tri (57.2 mm) -=91��- 4 l r 1-5/8" (41,3 mm) WRENCH STYLE 20 RECESSED *Temperature 5--_ ,c` FLATS ESCUTCHEON m.rating is ;.R. —... -•— _—._. indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 SERIES LFII(TY2234)RESIDENTIAL PENDENT AND RECESSED PENDENT SPRINKLERS 2-7/8-DIA. C< (73,0 mm) mm)1/2"1/2 12 7/16±1/8" ( ) (11,1±3,2 mm) 2-1/4-DIA_ 114"(6.4 mm) WRENCH RECESS (57,2 mm) (END"A'USED , FACE OF ^ FOR TY2234) SPRINKLER MOUNTING FITTING PLA I E FIGURE 3 lia .. II W-TYPE 6 �If SPRINKLER WRENCH MOUNTING SURFACE itp 1/8" WRENCH (3,2 mm) RECESS 1-3/8"(34,9 mm) - CLOSURE TY2234 1I/rr 1-1/8"(28,6 mm) FIGURE 2 4 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE SERIES LFII(TY2234) ..'a, RESIDENTIAL PENDENT SPRINKLER PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER distance of 1-3/8 to 4 inches or in WRENCHING AREA the recessed position using only the Style 20 Recessed Escutcheon as FIGURE 4 shown in Figure 2 W-TYPE 7 RECESSED Sprinkler Spacing. The minimum SPRINKLER WRENCH spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Ta- ble A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft.coverage area,or 20 feet for a 20 ft.x 20 ft. coverage area). TFP400 Page 5 of 8 ALL RDISTANCESARE AA-�+-A�-{ MEASURED TO f F F 14'(356 mm) COMPARTMENT MAXIMUM WALL FACES AND TO CENTERLINES : ; I_� OF BEAMS A=3'4'to6-0"(1,Oto1,8m) FOR PRIMARY BEAMS HAV- ING A 14'(356 mm)MAXIMUM DEPTH IIL ii PRIMARY 20'-0'(6,1 m) BEAM MAXIMUM COMPARTMENT WALLS FIGURE 6A PRIMARY BEAM SPANS UP TO 20'-0'(6,1 m) f F B i. A=3'd'to6'-0"(1.0 to 1,8 m) Piliallii111101111A FORPRIMARYBEAMS IMU SECONDARY B HAV- ING A 14'(356 mm)MAXIMUM BEAM I ________ - DEPTH B=2T-0"(6,1 m)MAXIMUM �- FOR SECONDARY BEAMS THAT ARE TO BE EQUAL IN BEAM PRIMARY Anil& - -I� DEPTH TO PRIMARY BEAMS AND THAT MUST BE IN PLACE - SO THAT PRIMARY BEAM POCKETS DO NOT IXCEED 20'-0"(6.1 m) COMPARTMENT .111 WALLS FIGURE 6B PRIMARY BEAM SPANS GREATER THAN 20'-0'(6.1 m) A • A � A� C A=3'-4 to 6'-0'(1.Oto 1.8m) ' 11� \ FOR PRIMARY B )MAXIMUM SECONDARY lE1_/ _.c_ C DEPTH BEAM ` C=3'-4 (1,0 m)MINIMUM FOR �€ SECONDARY BEAMS HAVING DEPTHS GREATER THAN 25% OF PRIMARY BEAMS PRIMARY* __ __ __ ; -a- BEAM C=ANY DISTANCE FOR SEC- ONDARY BEAMS HAVING DEPTHS UP TO 25%OF *REFER TO 1a PRIMARY BEAMS FIGURE 6B COMPARTMENT 1 FOR SPANS WALLS EXCEEDING 20'-0'(6,1 m) FIGURE 6C COMBINATIONS OF PRIMARY AND SECONDARY BEAMS FIGURE 6 BEAM ARRANGEMENTS (Refer to the"Beam Ceiling Design Criteria"section) Page 6 of 8 TFP400 SECONDARY -,�_��_'�_ BEAM ,17 PRIM ARY ,_ ;USE DISTANCES SHOWN E3FAM IN FIGURES 6A.6B 8 6C.EXCEMEUREMENTS ARE TAKEN FROM FACES OF SOFFITS INSTEAD OF FROM COMPARTMENT FACE OF �6_- WALL SURFACES SOFFIT , COMPARTMENT lillIllIllIllIll WALLS FIGURE 7 BEAM AND SOFFIT ARRANGEMENTS (Refer to the"Beam Ceiling Design Criteria"section) Step 3. Tighten the sprinkler into the Installation sprinkler fitting using only the W-Type Care and 6 Sprinkler Wrench (Ref. Figure 3). The Series LFII (TY2234) must be in- With reference to Figure 1,the W-Type Maintenance stalled in accordance with the follow- 6 Sprinkler Wrench is to be applied to ing instructions: the wrench flats. The Series LFII (TY2234) must be NOTES maintained and serviced in accord- Do not install any bulb type sprinkler if The Series LFII Recessed Pendent ance with the following instructions: the bulb is cracked or there is a loss of Sprinklers must be installed in ac liquid from the bulb. With the sprinkler cordance with the following instruc- NOTES held horizontally, a small air bubble lions. Absence of an Escutcheon Plate may should be present. The diameter of the Step A. Recessed pendent sprinklers delay the sprinkler operation in a fire air bubble is approximately 1/16 inch are to be installed in the pendent posi- situation. (1,6mm). lion with the deflector parallel to the ceiling. Before closing a fire protection system A leak tight 1/2 inch NPT sprinkler joint g. main control valve for maintenance should be obtained with a torque of 7 Step B. After installing the Style 20 work on the fire protection system to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- Mounting Plate over the sprinkler which it controls, permission to shut mum of 21 ft.lbs. (28,5 Nm)of torque threads and with pipe thread sealant down the affected fire protection sys- is to be used to install sprinklers. applied to the pipe threads, hand tem must be obtained from the proper Higher levels of torque may distort the tighten the sprinkler into the sprinkler authorities and all personnel who may sprinkler inlet with consequent leak- fitting. be affected by this action must be no- age or impairment of the sprinkler. tified. Step C. Tighten the sprinkler into the Do not attempt to compensate for in- sprinkler fitting using only the W-Type Sprinklers which are found to be leak- sufficient adjustment in an Escutcheon 7 Recessed Sprinkler Wrench (Ref. ing or exhibiting visible signs of corro- Plate by under-or over-tightening the Figure 4). With reference to Figure 1, sion must be replaced. Sprinkler. Readjust the position of the the W-Type 7 Recessed Sprinkler sprinkler fitting to suit. Wrench is to be applied to the sprinkler Automatic sprinklers must never be wrench flats. painted, plated, coated, or otherwise The Series LFII Pendent Sprinklers altered after leaving the factory. Modi- must be installed in accordance with Step D. After the ceiling has been in- fied sprinklers must be replaced. the following instructions. stalled or the finish coat has been ap- Sprinklers that have been exposed to Step 1. Pendent sprinklers are to be plied, slide on the Style 20 Closure corrosive products of combustion, but installed in the pendent position with over the Series LFII Sprinkler and have not operated,should be replaced the deflector parallel to the ceiling. push the Closure over the Mounting if they cannot be completely cleaned Plate until its flange comes in contact by wiping the sprinkler with a cloth or Step 2. With pipe thread sealant ap- with the ceiling. by brushing it with a soft bristle brush. plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Care must be exercised to avoid dam- • TFP400 Page 7 of 8 and after the sta lation - before, during, da - Limited Ordering • and after installation. Sprinklers dam- aged by dropping, striking, wrench Warranty Procedure twist/slippage,lippagege, o o the the like, must be re- placed.Also,replace any sprinkler that has a cracked bulb or that has lost Products manufactured by Tyco Fire 8 When placing an order, indicate the liquid from its bulb. (Ref. Installation Building Products (TFBP) are war- full product name. Contact your local Section). ranted solely to the original Buyer for distributor for availability.. ten(10)years against defects in mate- Sprinkler Assembly: The owner is responsible for the in- rial and workmanship when paid for p y: spection, testing, and maintenance of and properly installed and maintained Series LFII(TY2234),K=4.9,Residen- their fire protection system and de- under normal use and service. This tial Pendent Sprinkler with (specify) vices in compliance with this docu- warranty will expire ten (10) years temperature rating and (specify) fin- ment, as well as with the applicable from date of shipment by TFBP. No ish, P/N (specify). standards of the National Fire Protec- warranty is given for products or com- tion Association (e.g., NFPA 25), in ponents manufactured by companies 155°F/68°c or addition to the standards of any other not affiliated by ownership with TFBP Chrome Plated P/N 51-201-9-155 authorities having jurisdiction. The in- or for products and components onents which 155°F/68°C stalling contractor or sprinkler manu- p p whae Polyester P/N 51-201-4-155 9 P have been subject to misuse,improper 155°El68°C facturer should be contacted relative installation, corrosion, or which have White to any questions. not been installed, maintained, modi- (RAL9010)* P/N 51-201-3-155 fled or repaired in accordance with a _ 15s°F/sa°c NOTE p p Natural Brass P/N 51-201-1-155 plicable Standards of the National Fire 175°Fr79°C or The owner must assure that the sprin- Protection Association, and/or the Chrome Plated P/N 51-201-9-175 klers are not used for hanging of any standards of any other Authorities 175°F/79°c objects and that the sprinklers are only Having Jurisdiction. Materials found 175:NF/79°C Polyester PM 51-201-4-175 cleaned by means of gently dusting by TFBP to be defective shall be either Whae with a feather duster;otherwise, non- repaired or replaced, at TFBP's sole (RAL9010) P/N 51-201-3-175 operation in the event of a fire or inad- option. TFBP neither assumes, nor 175°Fn9°C vertent operation may result. authorizes any person to assume for it, Natural Brass P/N 51-201-1-175 It is recommended that automatic any other obligation in connection with *Eastern Hemisphere sales only. sprinkler systems be inspected, the sale of products or parts of prod- tested, and maintained by a qualified ucts.TFBP shall not be responsible for Recessed Escutcheon: Inspection Service in accordance with sprinkler system design errors or inac- local requirements and/or national curate or incomplete information sup- Specify: Style 20 Recessed Escutch- codes. plied by Buyer or Buyer's repre- eon with (specify') finish, P/N (spec- sentatives. ify')• In no event shall TFBP be liable, in *Refer to Technical Data Sheet TFP770. contract, tort, strict liability or under . any other legal theory, for incidental, Sprinkler Wrench: indirect,special or consequential dam- Specify: W-Type 6 Sprinkler Wrench, ages,including but not limited to labor P/N 56-000-6-387. charges, regardless of whether TFBP was informed about the possibility of Specify: W-Type 7 Sprinkler Wrench, such damages, and in no event shall P/N 56-850-4-001. TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products,materi- als or components,whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law.The invalidity,in whole or part, of any portion of this warranty will not affect the remainder. QUICK RESPONSE ia', AUTOMATIC SPRINKEWBD 'fr FIRE SPRINKLER GL SERIES p PR 2 3 2009 • CORPORATION DRY TYPE crry� DIVISION A HORIZONTAL SIDE OPAL RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes _ , a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature,the sprinkler opens releasing the bulb seat,causing the inner tube assembly to move,allowing the spring assembly to pivot alongside the inner tube.At this time,water flows through the sprinkler and is distributed by the deflector,in an approved discharge QUICK RESPONSE pattern. While the Quick Response Sprinkler provides an aesthetically pleasing appear- DRY NON-ADJUSTABLE ance, it can be installed wherever standard spray sprinklers are specified but offers the HORIZONTAL SIDEWALL additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed,the liquid within the bulb expands increasing the internal pressure. At tit t the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA QUICK RESPONSE DRY SLEEVE&SKIRT • See reverse side for Approvals and Specifications. HORIZONTAL SIDEWALL • Temperature Ratings- 135°F(57°C), 155°F(68°C), 175°F(79°C), 200°F (93°C),286°F (141°C). • Water Working Pressure Rating- 175 psi (12 Bars). • Factory tested hydrostatically to 500 psi (34 Bars). • Maximum low temperature glass bulb rating is-67°F (-55°C). • Frame- bronze • Deflector-brass • Screw- brass • Bulb seat- brass • Spring -teflon coated nickel alloy • Retainer- brass • Pin-stainless steel • Torsion spring-stainless steel • Bulb-glass with alcohol based solution, 3mm • Orifice insert- brass QUICK RESPONSE • 3/4" NPT or I" NPT • Outer tube -galvanized steel pipe DRY RECESSED • Inner tube -stainless steel HORIZONTAL SIDEWALL •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F P.A.MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY - ORANGE/RED = INTERMEDIATE �. YELLOW/GREEN " HIGH BLUE .z_ y . .. 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 OCTOBER 2005 A-58 BULLETIN GL5641, REV.#1 I QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE HORIZONTAL SIDEWALL RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES Factory Bronze 5.6 (80 metric) 3/4"or 1" NPT 'Satin Chrome Variable Bright Chrome to 48" White Polyester' 8.1 (116 metric) r NPT Black Polyester' 'Lead Coated NOTE METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER 'cULos LISTED FOR UP TO A 48""A"DIMENSION. 3C-U.L LISTED CORROSION RESISTANT- APPROVALS POLYESTER MUST BE SPECIFIED ON ORDER. SIN K THREAD I35•F 15S•F 175'F 200•F 2e6•F NYC-DOB STYLE CODE FACTOR S E S7'C 68'C 79°C 93°C 141°C CULus !SEA 101.92-E GL5641 5.6§ 1'NPT X X X X X X X HORIZONTAL GL5647 5.6§ 314"NPT X X X X X X X SIDEWALL GL8141 8.11 I•NPT X X X X X X X RECESSED GL5641 5.6§ I"NPT X X X X X X X HORIZONTAL G15642 5.6§ 3,4•NPT X X X X X X X SIDEWALL GL814I 8.1 1 I"NPT X X X X X X X 9 LISTED FOR UGHT HAZARD ONLY WITH DEFLECTOR FROM 4 TO 12"BELOW THE CEILING. LUSTED FOR LIGHT AND ORDINARY HAZARD WITH DEFLECTOR FROM 4"TO 12"BELOW THE CEILING. IMPORTANT INSTALLATION DATA CROSS SECTIONS Globe GL Series Dry Horizontal Sidewall sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, _ i _ the proper sprinkler head wrench may be used with extreme L care for lengths uptoapproximately 18". Excessiveforcemay c-== G ■ + ,LI distort the frame thus destroying the unit. II I'i��..,I I' :. For further important installation data,please refer to 1__.E" J , .r, °. 7:,., i1 �I our Dry Sprinkler Caution Sheet h 4 O. ORDERING INFORMATION SPECIFY EXTENDED RECESSED •Quantity • Model Number • Style HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL •Orifice • Temperature • Finishes desired - •Quantity-Wrenches-P/N 333010 ft.., nil •Quantity-Recessed Wrenches-P/N 337014 �.. e .r. r •Quantity-Protective Caps-P/N 327109-CAP(Friction -;L 5 Fit Recessed) • Escutcheons desired I) —1 r• I' _'�I ,.�• •"A"Dimension-Distance from face of fitting to the .. t" ■ ,. . N r finished ceiling regardless of escutcheon used. l m,. / 7r.°° ! 4 °°'°' GLOBE®PRODUCT WARRANTY -;,;.._. Globe agrees to repair or replace any of its own manufac- NON-ADJUSTABLE SLEEVE&SKIRT tured products found to be defective in material or workman- HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL ship for a period of one year from date of shipment. • For specific details of our warranty please refer to Price List Terms and Conditions of Sale(Our Price List). ears LOBE 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 •1'N FIRE SPRINKLER CORPORATION 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com OCTOBER 2005 PRINTED U.SA. BULLETIN GL5641, REV.#1 I CENTRAL 513, 513D/513R 1 -03 Riser Manifold Figure 513, 513D/513R Commercial CENTRAL - NFPA 13 Systems Grooved Piping Products Floor Control - High Rises Residential - NFPA 13D/13R Systems Tyco Fire Products—www.tyco-grooved.com 451 North Cannon Avenue, Lansdale,Pennsylvania 19446—USA Customer Service/Sales:Tel:(215)362-0700/Fax:(215)362-5385 Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 General The threaded ends of the 1"and 11/2" bodies,the threaded by grooved ends Technical of the 2"bodies,and the grooved ends Description of the 11/2"-6"bodies allow for an easy Data transition to either check or control m-.. m.,. ., valves.The exclusive and dedicated • • flow switch designed for the manifolds Figure: 513(commercial) r. c' has been tested and Listed for use in 513D(residential) --f this specific configuration by 513D/513R(residential) • _ - Underwriters Laboratories, Styles:Threaded or Grooved Underwriters Laboratories of Canada Sizes:1', 11/2',2",2W,3',4'and 6' and Factory Mutual. L _.3 Approvals: UL, FM,and ULC Installation is simplified with one Maximum iEregj convenient take-out for the 1"and 1'/2" Working Pressure: 175 psi threaded and 112"grooved versions,as Standard Finish: Painted PA well as one take-out for the 2"threaded by grooved and the grooved sizes Optional Accessories: 2"-6". Pressure Relief Valve Kit(see page 7) See Fire Protection ® �C Submittal Sheet for The Riser Manifold is approved for ® pressure rating and Listing installation in either the horizontal or and Approval information the vertical position.The optional relief valve assembly is available for The Figure 513,513D/513R Riser locations which require relief valves on Manifold provides all of the accessory gridded systems. equipment for a riser in a single assembly. The availability of the Riser Riser Manifolds for use in Canada only Manifold in different configurations are provided with a Water Flow Switch allows cost effective riser installation in that has a Tamper Switch mounted commercial(NFPA 13)systems,high inside for cover removal detection. rises requiring floor control assemblies, and residential systems (NFPA 13D/13R). No. 28-1.0 1 3.63 Figure 1 ;— [92.2] —I 1"Threaded Residential Riser Manifold Figure 513D 1 I •.63[16] BOTH ENDS 0 30.1_ T Approximate Trimmed Weight-7.5 lbs. (3.4Kg.) CO ii �� mm� 0 The width of the Riser Manifold is approximately 3W. — •.38 0.00 19-71 a l i d Note: Items 7&8 are used on Manifolds for use [2 1 MIMI V CO in Canada Only i 4.50 FLOW [114.3] a I IZ O 2.88 [73.2] Figure 1 -Bill of Material r 9.75 V Threaded Residential Riser Manifold 1247.71 -Detail Part Description No. Part thread engagement. No. Req'd Number Note:Values shown in parenthesis 1 Manifold Body F x F 1 976-363-01 are in millimeters 2 Potter Waterflow Switch I VSR-SF w/Paddle 1 H-416-01 3 V. Water Pressure Gauge 1 971-118-02 4 W 90°Street Elbow 1 H-463-075 5 3/4'Close Nipple 1 H-474-12 6 3/4"Ball Valve 1 971-116-02 7 Tamper Switch(ULC only) 1 H-419-01 8 Label(ULC only) 1 976-343-01 5.38 Figure 2 [136.7] 11/2"Threaded Residential Riser Manifold 1 I •.63(16] Figure 513D/513R I Reference Figures 2 and 3 I l I Bill of Materials(page 3) ® _- I i 10 1.7 ' ' I) 11,Approximate Trimmed Weight-8.7 lbs. (3.9Kg.) ��2`w( °"°" 10 00 I 0 The width of the Riser Manifold is approximately 3W. 12541 0 - 1 .63 (161 �� - Note:Items 16& 17 are used on Manifolds for use ,�� i in Canada Only. MIMI R, x ® j A --- 3 r.--, r t J e en ° 2.13 41-..- 4.50 1 1 '.63 [54 11 — [114.3] [161 41 1125 11.38[289.1] 1285.81 - -Approximate thread engagement. Note:Values shown in parenthesis are in millimeters Male x Male Body Option 2 Figure 3 1W Threaded Commercial Riser Manifold Figure 513 For optional pressure relief valve,see Figure 10(page 7) 12.50 1317.5] _ - 6.25 1158.8] --.—I / Approximate Trimmed Weight-11.2 lbs. (5.1Kg.) '.63[16] . / \ The width of the Riser Manifold is approximately 3W. 1 I \_., 8 o + f Note:Items 16& 17 are used on Manifolds for use -I •�pIC minti-l:• 38 in Canada Only. 11 0 3] Al rill, D 0 0 0 10.00 [2541 ; s 0 i 0 FlL 51) ® ' .o e o r 1 °o t 1 , 1 I 11.25 O 1.13 j T 61 � _11 [1 1285.8] [28.7] [16] 5.50 OM [139.7] `Approximate thread engagement. Male x Male Body Option Note:Values shown in parenthesis are in millimeters Figures 2 and 3-Bill of Material . 1W Threaded Residential and Commercial Riser Manifold Detail Description No.Req'd Part No. Corn. Res. Number 1 Manifold Body M x F 1 1 976-339-01 2 Potter Waterflow Switch#VSR-SF w/11/4'Paddle 1 1 H-416-02 3 1'Ball Valve F101 0 1 971-116-03 4 V x'/2'x V Reducing Tee 1 0 H-469-100-050-100 5 V Insp.Test&Drain Valve F202 w/'/{Test Orifice 1 0 971-122-04 6 Sight Glass M x F 1 0 Fl-418-100 7 /a'Water Pressure Gauge 0 1 971-118-02 7a '/,'Water Pressure Gauge 1 0 971-118-01 8 W Pipe Plug 1 0 F1450-025-000 9 /'3-Way Globe Valve 1 0 971-119-01 10 'h'x 3'Nipple 1 0 H-459-025-30 11 V x W x1'California Tee 0 1 976-385-01 12 /2'Pipe Plug 1 1 H450-050-000 13 1'Close Nipple 0 1 H-474-16 14 1'Ball Valve 1 0 971-121-01 15 1W Close Nipple 1 1 H-474-24 16 Tamper Switch(ULC only) 1 1 H-419-01 17 Label(ULC only) 1 1 976-343-01 3 Figure 4 — 12.50[3175) 1'/'Grooved Commercial Riser Manifold - Figure 513 - 6.25[158.8] ---.--I For optional pressure relief valve, see Figure 10(page 7) 0 io 0 z • 4111 _ II . 1 14.38 b ®�" g Approximate Trimmed Weight 11.2 lbs. (5.1 Kg.) [365.3] ' �i ^I� © O 10.00 �_ 0 The width of the Riser Manifold is approximately 3W. [2`54] Note: Items 12 & 13 are used on Manifolds for use in Canada Only. S=" [ I s 0 t A i 1.13 J 1 1 [287) [16] I� 5.50 1 Figure 4-Bill of Material [139.7] 11/2'Grooved Commercial Riser Manifold Detail No. Part 'Approximate thread Description engagement. No. Req'd Number Note:Values shown in 1 Manifold Body G x G 1 976-399-02 parenthesis are in millimeters 2 Potter Waterflow Switch A VSR-SF w/11/4'Paddle 1 H-416-02 3 1'Ball Valve F101 1 971-121-01 4 1'Insp.Test& Drain Valve F202 w/'/'Test Orifice 1 971-122-04 5 Sight Glass M x F 1 H-418-100 6 /4'Water Pressure Gauge 1 971-118-01 7 /4'Pipe Plug 1 H-450-025-000 8 W 3-Way Globe Valve 1 971-119-01 9 '/4'x 3'Nipple 1 H-459-025-30 - 10 V x''/z'x V Reducing lee 1 H-469-100-050-100 11 1/2'Pipe Plug 1 H-450-050-000 12 Tamper Switch(ULC only) 1 H-419-01 13 Label (ULC only) 1 976-343-01 Figure 5 12.00[304.8] 2'Grooved Residential Riser Manifold 5.4411382] Figure 513D/513R noni■ Reference Figures 5 and 6 Bill of Materials(page 5) a...11 � ' l For optional pressure relief valve,see Figure 10(page 7) .w T \I) , CO o� Approximate Trimmed Weight-11.0 lbs. (5.0Kg.) - 0 13.00 �n The width of the Riser Manifold is approximately 3W. l 2 ® ',j In' � _ 0 © FL� Note: Items 16& 17 are used on Manifolds for use in Canada Only. . 63 1161 'MIMES ■ I-� ft 4...1300[330.2] — • 225 I� 4.50 �� 25 �° [572] — [114.3] °o 0o 'Approximate thread engagement. 2'Male x Groove Body Option Note:Values shown in parenthesis are in millimeters 4 c Figure 6 -- 0 2',21/2',3',4',and 6' Grooved Commercial Riser Manifold- Figure 513 - 5.5011391] • For optional pressure relief valve,see Figure 10 (page 7) t Approximate Weights and Dimensions of Trimmed 0 � „E 0:. 2',21/2',3',4',and 6'Grooved Commercial Riser Manifolds t2 e' A B C D Appx.Width Weight n �' p I 9 2 Inches Inches Inches Inches Inches Inches Lbs. r it `°J mm mm mm mm mm Kg. ••1300 `■ €� 0 2 17.13 0.88 12.88 5.25 3.50 13.5 r330 21 pp Ir "' 'I 0 135.0 22.2 327.0 139.7 88.9 6.1 I. = maw 18.13 1.88 13.75 6.38 3.50 16.8 �.I Q a - 2/2 460.4 47.6 349.3 155.6 88.9 7.6 '• 13 mire 3 18.13 1.88 14.38 6.25 3.50 18.7 460.4 47.6 365.1 158.8 88.9 8.5 �`' • _.______ 4 20.00 3.75 17.38 8.38 4.50 32.7 Llordi 508.0 95.3 441.3 212.7 114.3 14.8 1 i 6 20.00 3.75 19.25 9.25 6.63 41.6 631161 -i 508.0 95.3 489.0 235.0 182.3 18.9 I- o 'Approximate thread engagement. "13'is the take-out for all sizes 2'through 6' Figure 5 and 6-Bill of Material Note:Values shown in parenthesis are in millimeters 2'Grooved,2'Threaded x Grooved and 2',2V2',3',4',and 6'Commercial Riser Manifold Detail- No. Part No. Description Req'd Number 2'Manifold Body Groove x Groove 1 976-254-01 2W Manifold Body Groove x Groove 1 976-254-02 1 3'Manifold Body Groove x Groove 1 976-254-03 4'Manifold Body Groove x Groove 1 976-254-04 6'Manifold Body Groove x Groove 1 976-254-05 la 2'Manifold Body Male x Groove 1 976-411-01 Potter Waterflow Switch#VSC w/2'Paddle 1 976-357-01 Potter Waterflow Switch#VSC w/21/2'Paddle 1 976-357-02 2 Potter Waterflow Switch#VSC w/3'Paddle 1 976-357-03 Potter Waterflow Switch#VSC w/4'Paddle 1 976-357-04 • Potter Waterflow Switch#VSC w/6'Paddle 1 976-357-05 V Ball Valve F101 (2') 1 971-121-01 3 11/4'Ball Valve F101 (2'/2'and 3') 1 971-121-02 2'Ball Valve F101 (4'and 6') 1 971-121-03 1'Insp.Test&Drain Valve F202(2')w/'12'Test Orifice 1 971-122-04 4 11/4'Insp.Test& Drain Valve F202(2'/2'and 3')w/'/2'Test Orifice 1 971-122-05 2'Insp.Test&Drain Valve F202(4'and 6')w/'h'Test Orifice 1 971-122-06 1'Sight Glass(2') 1 H-418-100 5 1' 'Sight Glass(2'/2 and 3') 1 H-418-125 2'Sight Glass(4'and 6') 1 H-418-200 6 1/4'Water Pressure Gauge 1 971-118-01 7 Y;Pipe Plug 1 H-450-025-000 8 1/4'3-Way Globe Valve ' 1 971-119-01 9 /4'x 3'Nipple 1 H-459-025-30 10 1'Pipe Plug 1 H-450-100-000 1°x''/2'x 1'Reducing Tee(2') 1 H-469-100-050-100 11 1W x'/2'x 1'/4'Reducing Tee(2W and 3') 1 H-469-125-050-125 - 2'x 1/2'x 2'Reducing Tee(4'and 6') 1 H-469-200-050-200 ' 12 W Pipe Plug 1 H-450-050-000 13 1'x 1/2'x 1'California Tee ' 1 976-385-01 • 14 1'Close Nipple 1 H-474-16 15 1' Ball Valve F101 1 971-116-03 - 16 Tamper Switch(ULC only) 1 H-419-01 _ 17 Label(ULC only) _ 1 976-343-01 • Note: Items 16& 17 are used on Manifolds for use in Canada Only. 5 Figure 7 Potter Waterflow Switch Terminal Connections �►` ��4G -4CP Caution: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections,thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. o\NG QJ� Figure 8 Potter Waterflow Switch Typical Electrical Connections Style B/Class B Local Bell Transformer or Line of Line Resistor Battery Powered CKT.(see note) Open on Alarm Close on ----0 Alarm Open on V Close on End of Line Alarm �l Alarm Resistor Signaling Device <r- Supervised I Supervised Loop Typical Switch Action (see note) v „v. / To Additional Open on Close on From Open on 10 Close on Devices or Alarm • • Alarm Control Alarm i Alarm Return to Panel \ Control Note: For supervised circuits,see'Switch Terminal Connections'and caution note(above).The Model VSC and Model VSR-SF have two switches, one can be used to operate a central station, proprietary or remote signaling unit,while the other contact is used to operatea local audible or visual annunciator. Testing: The frequency of testing for the Model VSC and Model VSR-SF and their associated protective monitoring system should be in accordance with applicable NFPA Standards and/or the Authority Having Jurisdiction, but under no circumstances less than bimonthly. Figure 9 Potter Tamper Switch Typical Electrical Connection Contacts S.P.D.T.(form C) N.C. v Com. Contacts shown with Cover in Place Contact Rating: 5A6f4125V AC N.O. 2.5A @30V DC Installation for Models VSC and VSR-SF: Remove the one retard assembly mounting screw. Place the switch assembly over the retard mounting tab. Replace the screw. 6 t4 Limited Products neither assumes,nor Ordering _ authorizes any person to assume for it, any other obligation in connection with Warranty n the sale of products or parts of Procedure products. Tyco Fire Products shall not Products manufactured by Tyco Fire be responsible for sprinkler system Ordering Information: When placing an Products are warranted solely to the design errors or inaccurate or order,indicate the full product name.Please original Buyer for ten(10)years against incomplete information supplied by specify the quantity,figure number,style, defects in material and workmanship Buyer or Buyer's representatives. and size.(see page 7 for figure and part when paid for and property installed IN NO EVENT SHALL TYCO FIRE numbers) and maintained under normal use and PRODUCTS BE LIABLE, IN Availability and Service: Grooved Piping service. This warranty will expire ten CONTRACT,TORT, STRICT Products,valves,accessories and other (10)years from date of shipment by LIABILITY OR UNDER ANY OTHER products are available throughout the U.S., Tyco Fire Products. No warranty is LEGAL THEORY, FOR INCIDENTAL, Canada,and internationally,through a given for products or components INDIRECT, SPECIAL OR network distribution centers.You may write manufactured by companies not CONSEQUENTIAL DAMAGES, directly or call 215-362-0700 for the affiliated by ownership with Tyco Fire INCLUDING BUT NOT LIMITED TO distributor nearest you Products or for products and LABOR CHARGES, REGARDLESS OF components which have been subject WHETHER TYCO FIRE PRODUCTS to misuse,improper installation, WAS INFORMED ABOUT THE Care and corrosion,or which have not been POSSIBILITY OF SUCH DAMAGES, installed,maintained,modified or AND IN NO EVENT SHALL TYCO Maintenance repaired in accordance with applicable FIRE PRODUCTS' LIABILITY EXCEED Standards of the National Fire AN AMOUNT EQUAL TO THE SALES Protection Association(NFPA),and/or PRICE. The owner is responsible for the the standards of any other Authorities THE FOREGOING WARRANTY IS MADE inspection,testing,and maintenance of Having Jurisdiction. Materials found by THE LIEU EGOING WARRANTY OTHER their fire protection system and devices Tyco Fire Products to be defective shall IN LIEU IMPLIED in accordance with the applicable be either repaired or replaced,at Tyco INCLUDING WARRANTIES OF standards of the National Fire Fire Products' sole option. Tyco Fire Protection Association(e.g., NFPA 25), MERCHANTABIUTYAND FITNESS in addition to the standards of any FOR PARTICULAR PURPOSE authority having jurisdiction.The installing contractor or product manufacturer should be contacted relative to any questions.Any impairment must be immediately corrected. It is recommended that automatic • sprinkler systems be inspected,tested, and maintained by a qualified Inspection Service. General Notes:It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and 41/ ISO understand the installation instructions(lH-1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and ", 9001 p gasket selection should be verified to be compatible for the specific application. •� 10 Certified Company NCO I Flow Control I Tyco Fire Printed in U.S.A. 1-03 Products 8 1 tqCQ Fro w Tyco Fire Control Products B/azeMaster FIRE SPRINKLER PIPE & FITTINGS SUBMITTAL SHEET TYCO FIRE PRODUCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.corn TEC r SERVICES TEL (800) 381-9312 • FAX (800) 791-5500 E-MAIL techserv@tycofp.com IIIIIIIIIIIOIIMII 111111111110M___ ...... 3 ar-.S , s. T. c r No. 19-1.5 TD915 4-1.1 91200.20 1 • i15o 0 �. Introduction Tyco Fire Products(TFP) BlazeMaster CPVC pipe and the same time,they provide superior heat resistance and fittings are designed exclusively for use in wet pipe strength as compared to traditional CPVC and PVC piping automatic fire sprinkler systems.They are made from a materials used in the plumbing trade. Various adapters are specially developed thermoplastic compound composed of available to connect CPVC pipe to metallic piping.All female post chlorinated polyvinyl chloride (CPVC) resin and state of pipe thread adapters have brass inserts for durability. the art additives.TFP BlazeMaster°'CPVC products are Grooved adapters connect directly to grooved end valves easier to install than traditional steel pipe systems,and at and metallic pipe,with flexible grooved end couplings. Technical Data Sizes: '/:-3' Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM,CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA,and the City of t.os Angeles Fittings: ASTM F438(Sch.40)and Note: See current TFP BlazeMaster Installation Instructions and ASTM F439(Sch.80) Technical Manual,for exact listing/approval information Color: Orange Pipe Nom.Pipe Size Avg.O.D.Inches Avg.I.D.Inches Wt.Lbs./Ft. Wt.IfA fined Pipe Lbs./Ft. Ft.of Pipe per Lift Wt.per Lift Lbs. 1/4 1.050 0.874 0.17 0.43 7875 1413 1' 1.315 1.101 0.26 0.67 5040 1320 17,' 1.660 1.394 0.42 1.07 2835 1191 11/2' 1.900 1.598 0.55 1.40 2205 1136 2' 2.375 2.003 0.86 2.20 1260 1063 2 72" 2.875 2.423 126 3.22 1215 1531 3' 3.500 2.952 1.87 4.79 720 1344 Fittings To Tro' TAD 45° Elbow _ iipteN T� Reducing _. ®p►� 90° Elbow = ; 90 Elbow T/01 . liiI -1,11 Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80050 Y4 40 3/e 0.08 lb. No. Size Sch. 1 2 lb. 80025 3/4 40 9/,e 0.09 lb. 80051 1' 40 3/e 0.11 lb. 80032 1'x'/: 40 "/,e '/1e 0.16 80026 1' 40 3/: 0.14 lb. 80052 11/ 40 3/: 0.20 lb. 80027 1'/i 40 '/e 0.21 lb. 80053 1'/2' 80 '/+e' 0.31 lb. 80028 1112 80 1'/,e 0.40 lb. 80054 2' 80 3/4 0.56 lb. 80029 2' 80 1'/4' 0.79 lb. 80055 2'/2" 80 '/: 0.89 lb. 80030 2'/2' 80 1'/2" 1.14 lb. 80056 3` 80 1' 1.19 lb. 80031 3" 80 1"/1e 1.82 lb. 1 __Iii),i L t Tee - ? CReducing =_M_- Cross _,O.- l Tro I I r!o vo' ilir Tro In PO' Mil lid 1/0 Mil TAD Part No. Size Sch. T/O Wt. Part T/O Wt. Part No. Size Sch. T/O Wt. 80000 '/: 40 5/e 0.11 lb. No. SiZe ' 1 2 lb. 80009 '/: 40 9/,e 0.13 lb. 80001 V 40 3/4' 0.19 lb. 80015 1'x'/4 40 11/1e' "/.' 0.28 80010 1' 40 11/4e' 0.23 lb. 80002 11/: 40 '/e' 0.26 lb. 80011 11i 40 15/+e' 0.34 lb. 80003 11/21 80 1' 0.51 lb. 80012 1'/2' 80 1'/,e' 0.67 lb. 80004 2' 80 1'/e 0.90 lb. 80013 2' 80 1'/e' 1.00 lb. 80005 21/z 80 1'/1e' 1.59 lb. 80014 2'/2' 80 19/ie 1.91 lb. 80006 3" 80 1"/,8"_ 2.41 lb. 80008 3' 80 113/,8' 2.89 lb. T;O Sprinkler Head Adapter _ -I��� _ Sprinkler Head Adapter Trui with Brass Threaded Insert ,-,� with Brass Threaded Insert Part No. Size Sch. T/O Wt. Part No. Size Sch. T/O Wt. 80175E '/e'x1/2" NPT 80 '/+e' 0.20 lb. 80175W '/e'x '/i NPT 40 '/,s 0.19 lb. 80176E 1' x 1/2 NPT 80 '/,e 0.22 lb. 80176W 1'x '/z" NPT 40 _ '/1e' 0.18 lb. 80177WL 3/4 x12'NPT 40 s/'e" 0.16 lb. 80179 1 x'/: NPT 40 1/4' 0.43 lb. -rro' T/0 �. . Back-to-Back Cross --11112/111 Sprinkler Head Adapter may.,, with Brass Threaded Insert (Spigot) -T/O' with Brass Threaded Insert I/O T/O Part No. Size Sch. T/O Wt. Part T/O Wt. 80177L 3/4'x '/z'NPT 40 '/z' 0.16(b. No. Size Sch. 1 2 lb. 80178 1'x 72 NPT 40 '/z' 0.20 lb. 80462 1'x 1'x '/2 NPT x 1/2 NPT 40 '/8 118 0.46 80463 1'x 1'x 12 NPT x 1/2' NPT 40 '/e' 15/,e 0.47 T/0' Sprinkler Head Adapter 90° Elbow ,.. Back-to-Back Tee T'° ..� with Brass Threaded Insert ras T.— 11111111111011 011 ��`• with Brass Threaded Insert I lijatamjii' T/0' I/O 2 Part T/O Wt. Part Size Sch. T/O Wt. No. Size �. 1 2 lb. No. 1 2 lb. 80199 3/4"x '/z'NPT 40 5/8 '5/16' 0.20 80459 1'x 1/2' NPT x'/s' NPT 40 "/,e• 15/,6" 0.48 80189 1'x'/z'NPT 40 "/+a" 12/16" 0.26 80460 1'x /z' NPT x 1/2 NPT 40 "/+e' 1'/a" 0.46 Part T/O Wt. Size Sch. 1 2 3 lb. No.80250 7/ x 3/+'x1/2 NPT 40 5/8 '/8 1" 0.22 80251 1'x 1'x'/z"NPT 40 "ha "he' '3/,e' 0.29 1�! 80249 1'x 1'x 1' NPT 40 15/+e' 15/1e" 1'/,e' 0.73 Sprinkler Head Adapter -' 'p " Tb°' 80256 1'1:x 1"x 72 NPT 40 '/,: °/,8 17R 0.30 Tee -. --- 80252 1114'x 17:x'/2 NPT 40 718 'he" 17... 0.31 with Brass Threaded Insert 80257 172 x 17:x'/2 NPT 80 a/,a '/8 1'/,8 0.43 T/0' 11111111 Pd 80254 1'/2 x 1'/2'x'/2 NPT 80 °/,e °/be" 1'/,e" 0.46 80258 2'x 112 x'12 NPT 80 '/z 5/8 we 0.56 80253 2'x 2'x'/2 NPT 80 '/z' 72 we 0.62 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten(10)years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten(10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse,improper installation,corrosion,or which have not been installed,maintained,modified or repaired in accordance with applicable Standards of the National Fire Protection Association(NFPA),and/or the standards of any other Authorities Having jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced,at Tyco Fire Products sole option. Tyco Fire Products neither assumes,nor authorizes any person to assume for it.any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE.IN CONTRACT.TORT.STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY.FOR INCIDENTAL.INDIRECT,SPECIAL OR CONSEQUENTIAL DAMAGES,INCLUDING BUT NOT LIMITED TO LABOR CHARGES,REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES. • AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. • THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED.INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ti/CO/Flow Control/Tyco Fine Products . TOLCO www.tol,o.corr, NIBCO Re.,s,,. , s 24 2.0C:1 • Fig. 27 & 27A ®c® "Stand-Off" Hanger/Restrainer for CPVC Plastic Pipe Size Range— 3/4" and 1" CPVC Plastic Pipe". Material — Carbon Steel, Pre-Galvanized { Function —Designed to be used as a hanger/restrainer"for CPVC piping where the "stand-off"design will ease installation by eliminating the need for �' -- wood blocking. Features: • Flared edge design protects CPVC from any rough or abrasive surfaces. • Snap-in retainers hold pipe firmly in place during installation. - • The "Stand-Off"design eliminates the need for wood block extension. Fig. 27 • Can be installed on horizontal or vertical piping regardless of mounting '' surface orientation. •,." • Attaches easily to wood structure with two hex head self-threading Z--:-. 0 screws furnished with product. VI'� `i �� • Installs easily using rechargeable electrical driver with 5/16" sockets, 0 eliminating impact tool damage to pipe. M� f' Approvals — Underwriters'Laboratories Listed in the USA (UL) and Canada ��f (cUL) to support automatic fire sprinkler systems. Meets and exceeds the Fig. 27A requirements of NFPA 13, 13R and 13D. Important Note**—When installed in slot opening on Fig.27, Fig. 27A _ provides additional stability and satisfies the UL vertical restraint requirement where needed. i Order By— Fig. 27: By figure number and CPVC pipe size ,�' Fig. 27A: By figure number and CPVC pipe size \-2..--- i ';` ''' - US and International Patent application in process. : ; - • "For other sizes, consult factory. `t �' ti„ . Fig. 27 and Fig. 27/27A have also been tested by UL mounted on 3/8" composite wood web material (such as TJI Series/Trus Joist MacMillan) Fig. 27/Fig. 27A without the use of back-up wood blocking. When using Fig. 27 and 27A in combination on 3/8"web to satisfy the UL requirement for vertical restraint, FIG.27 install two reinforcing speed nuts (Fig.27B). Fig.27B is UL Listed only when _ W:FIG 27A used with TOLCOTM products. 1 i°iG.27B ..,L- FIG.27 dirl (.1c51-__ i W/FIG.27A i Fic.27 f, I — FIG.27 F ic; r■C 7 2 w FIG 27A F1G.27 "-t-' —± ---- f� ir 11 Typical Applications Office/Manufacturing Facility•1375 Sampson Ave.•Corona,CA 92879•Ph. 951.737.5599•Fax. 951.737.0330 S Customer Service•800.786.5266 wwwctokacao .1 (g) TOLCO www.tofco.com NIBCO Revision 5 2—21:0. Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount ®c® Size Range— 3/4" thru 2" CPVC pipe C` Material— Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger/restrainer to support only �.-... CPVC piping used in automatic fire sprinkler systems. Can be installed /• on the top or on the bottom of a beam. The Fig.24 can also function �f /' _= as a restrainer to prevent the upward movement of the sprinkler head ! 7� / during activation. it / ii fl Approvals— Underwriters'Laboratories Listed in the USA (UL) and f, Canada (cUL) to support fire sprinkler piping. Meets and exceeds the 1 L. .f requirements of NFPA 13, 13R and 13D. Features — Fig.24 incorporates features which protect the pipe and •, ease installation. The flared edge design` protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws"furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails)are allowed. Damage has ,f ■ been known to result from installations using impact type tools. No pre-drilling �� of a pilot hole in wood is required. �B'' q Finish — Pre-Galvanized yam'` Order By — Figure number and pipe size ' Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions •Weights CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 25h8 15/32 11,F 57, 5/16 9 1 25/" 1s/1a 1'/1A 6 5/16 9 1'/, 3 172 13/,6 6'/, 5/16 11 17, 37. 15/, 13/6 7 5/16 12 2 3"/,s 127/37 1'/,s 8 5/16 15 Office/Manufacturing Facility•1375 Sampson Ave.•Corona,CA 92879•Ph 951.731.5599•fax.951.737.0330 III Customer Service•800.706.5266 www.tolco.carn