Specifications
NAC EOL VOLTAGE CALCULATION J° 8- 3.37 CAPITOL ELECTRIC CO., INC. CEIjT (503) 255-9488 Office ED (503) 255-1966 Fax OCT 0 8 2008 Job Name: Five Lincoln Center CITy0F Job Address: 10200 SW Greenburg Road Tigard, OR 97223 BUILpj TIGgRD Job Number: NGDIVIS101V Prepared By: Dan Wilson Date: 10/3/2008 Panel Description: Silent Knight 5495 Power Supply Panel No.: NAC 7.1 NAC Devices Mfg By: System Sensor ALARM OUTPUT TOTALS OUTPUT 1 0.838 AMPS • OUTPUT 2 1.311 AMPS OUTPUT 3 0.000 AMPS OUTPUT 4 0.000 AMPS TOTAL 2.149 AMPS WIRE LENGTH TOTALS OUTPUT# WIRE LENGTH 1 GAUGE OUTPUT 1 268 14 OUTPUT 2 492 14 OUTPUT 3 0 14 OUTPUT 4 0 14 TOTAL 7601 FEET z5-Lincoln NAC 7.1 EOLv Calc.xls JOB INF SHEET NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. • (503) 255-9488 Office (503) 255-1966 Fax Job Name: Five Lincoln Center Job Address: 10200 SW Greenburg Road Tigard, OR 97223 Job Number: Conductor Wire Guage 14 Prepared By: Dan Wilson Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) 3.07 Date: 10/3/2008 Cable Length In Feet (source to end of line) 268 Total Circuit Current 0.838 Nominal System Voltage 20.4 Panel Description: Silent Knight 5495 Power Supply Minimum Device Voltage 16 Panel No.: NAC 7.1 Output No.: 1 Point To Point Method EOLv 19.46 Circuit Within Limits ? YES NAC Devices Mfg By: System Sensor End Of Line Method EOLv 19.02 Circuit Within Limits ? YES Load Centering Method EOLv 19.71 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet ) 1 Suite 700 SW 15cd Stb, Wall, Wht 15 0.066 75 20.01 2 Suite 700 P2W 15cd H/S, Wall, Wht, Med 15 0.069 24 19.90 3 Suite 700 P2W 75cd H/S, Wall, Wht, Med 75 0.157 34 19.75 4 Suite 700 P2W 30cd H/S, Wall, Wht, Med 30 0.097 32 19.65 5 Suite 700 SW 15cd Stb, Wall, Wht 15 0.066 35 19.55 6 Suite 700 P2W 75cd H/S, Wall, Wht, Med 75 0.157 19 19.51 7 Suite 700 P2W 75cd HIS, Wall, Wht, Med 75 0.157 29 19.46 8 Suite 700 HW Horn, White, High N/A 0.069 20 19.46 9 19.46 10 19.46 11 19.46 12 19.46 . 13 19.46 14 19.46 15 19.46 16 19.46 17 19.46 18 19.46 • 19 19.46 20 19.46 z5-Lincoln NAC 7.1 EOLv Calc.xls OUTPUT 1 NAC EOL VOLTAGE CALCULATION CAPITOL ELECTRIC CO., INC. (503)255-9488 Office (503) 255-1966 Fax Job Name: Five Lincoln Center Job Address: 10200 SW Greenburg Road Tigard, OR 97223 Job Number: Conductor Wire Guage 14 Prepared By: Dan Wilson Ohms Per 1000 Ft @ 75 Deg C ( 167 Deg F ) 3.07 Date: 10/3/2008 Cable Length In Feet (source to end of line) 492 Total Circuit Current 1.311 Nominal System Voltage 20.4 Panel Description: Silent Knight 5495 Power Supply Minimum Device Voltage 16 Panel No.: NAC 7.1 Output No.: 2 Point To Point Method EOLv 18.42 Circuit Within Limits ? YES NAC Devices Mfg By: System Sensor End Of Line Method EOLv 16.44 Circuit Within Limits ? YES Load Centering Method EOLv 18.42 Circuit Within Limits ? YES Dev Device Location Device Model No. & Description Candella Alarm Distance From Voltage At No. Rating Current Previous Device Device ( Feet ) 1 Floor 7 Public Corridor P2W 75cd HIS, Wall, Wht, Med 75 0.157 45 20.04 2 Floor 7 Public Corridor P2W 110cd H/S, Wall, Wht, Med 110 0.201 50 19.68 3 Suite 700 P2W 75cd HIS, Wall, Wht, Med 75 0.157 36 19.47 4 Men's Restroom SCW 30cd Stb, Ceiling, Wht 30 0.094 55 19.20 5 Women's Rest Room SCW 30cd Stb, Ceiling, Wht 30 0.094 53 18.98 6 Floor 7 Public Corridor P2W 15cd HIS, Wall, Wht, Med 15 0.069 31 18.86 7 Suite 700 HW Horn, White, High N/A 0.069 38 18.73 8 Suite 700 P2W 30cd HIS, Wall, Wht, Med 30 0.097 38 18.62 9 Suite 700 HW Horn, White, High N/A 0.069 40 18.53 10 Suite 700 P2W 15cd H/S, Wall, Wht, Med 15 0.069 24 18.49 11 Suite 700 P2W 30cd H/S,Wall, Wht, Med 30 0.097 22 18.46 12 Suite 700 P2W 15cd H/S, Wall, Wht, Med 15 0.069 23 18.44 . 13 Suite 700 HW Horn, White, High N/A 0.069 37 18.42 14 18.42 15 18.42 16 18.42 17 18.42 18 18.42 • 19 18.42 20 18.42 z5-Lincoln NAC 7.1 EOLv Calc.xls OUTPUT 2 NAC EXTENDER BATTERY CALCULATIONS CAPITOL ELECTRIC CO•, INC. (503)255-9488 Office, (503)255-1966 Fax JOB NAME: Five Lincoln ADDRESS: 10200 SW Greenburg Rd Tigard,OR 97223 DATE: 10/3/08 PANEL DESCRIPTION: NAC 7.1 PREPARED BY: Dan Wilson DEVICE TOTAL DEVICE TOTAL STANDBY STANDBY ALARM ALARM DEVICE QUANTITY CURRENT CURRENT CURRENT CURRENT NAC EXTENDER Silent Knight 5495 NAC Panel 1 0.075 0.075 0.175 0.175 CIRCUIT#1 Suite 700 0.000 P2W 110cd H/S,Wall,Wht, Med 0.201 0.000 P2W 75cd H/S,Wall,Wht,Med 3 0.157 0.471 P2W 30cd H/S,Wall,Wht,Med 1 0.097 0.097 P2W 15cd H/S,Wall,Wht,Med 1 0.069 0.069 SW 15cd Stb,Wall,Wht 2 0.066 0.132 SCW 30cd Stb,Ceiling,Wht 0.094 0.000 HW Horn, High 1 0.069 0.069 0.000 TOTAL 0.838 CIRCUIT#2 Suite 700&Floor 7 Core 0.000 P2W 110cd H/S,Wall,Wht,Med 1 0.201 0.201 P2W 75cd H/S,Wall,Wht, Med 2 0.157 0.314 P2W 30cd H/S,Wall,Wht, Med 2 0.097 0.194 P2W 15cd H/S,Wall,Wht, Med 3 0.069 0.207 SW 15cd Stb,Wall,Wht 0.066 0.000 SCW 30cd Stb,Ceiling,Wht 2 0.094 0.188 HW Horn,High 3 0.069 0.207 0.000 TOTAL 1.311 CIRCUIT#3 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 CIRCUIT#4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 z5-Lincoln NAC 7.1 Batt Calc.xls Page 1 of 2 NAC EXTENDER BATTERY CALCULATIONS CAPITOL ELECTRIC CO•, INC. (503) 255-9488 Office, (503) 255-1966 Fax JOB NAME: Five Lincoln ADDRESS: 10200 SW Greenburg Rd Tigard,OR 97223 DATE: 10/3/08 PANEL DESCRIPTION: NAC 7.1 PREPARED BY: Dan Wilson DEVICE TOTAL DEVICE TOTAL STANDBY STANDBY ALARM ALARM DEVICE QUANTITY CURRENT CURRENT CURRENT CURRENT AUXILIARY DEVICES 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 STANDBY TOTAL CURRENT: 0.075 STANDBY HOURS: 24 STANDBY AMP HOURS: 1.800 NAC DEVICE CURRENT 2.149 ALARM TOTAL CURRENT: ( 2.324 ALARM MINUTES: 5 ALARM AMP HOURS: 0.194 TOTAL CALCULATED AMP HOURS 1.994 APPLIED SAFETY FACTOR 1.15 MINIMUM AMP HOURS REQURED 2.293 SELECTED BATTERY SIZE 12 EACH 12 VOLT, 7 AMP HOUR BATTERIES z5-Lincoln NAC 7.1 Batt Calc.xls Page 2 of 2 *Th, SYSTEM . ,,. _ SENSOR r . .. : .1 ,.. . 1 -'Nk 1 Selectable Output := p 4a, r Notification Devices 4 9 A i - ► 0 ,, .- ' if r ..'c--1:' . r. SpectrAlert Advance selectable output horns,strobes, —1;3 _. . and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. (- SPECTFw pert A a o/ Q 11J C E The SpectrAlert Advance series of notification appliances is Features designed to simplify your installations,with features such as:plug in .Plug-in design designs,instant feedback messages to ensure correct installation of individual devices,and eleven field-selectable candela settings for •Same mounting plate for wall-and ceiling-mount units wall and ceiling strobes and horNstrobes. -Shorting spring on mounting plate for continuity check before installation More specifically,when installing Advance products,first attach a • - universal mounting plate to a four-inch square,four-inch octagon or Captive mounting screw double-gang junction box.The two-wire mounting plate attaches to •Tamper resistance capability a single-gang junction box. -Field selectable candela settings on wall and ceiling units:15,15/75, Then,connect the notification appliance circuit wiring to the SEMS 30,75,95,110,115,135,150,177,185 terminals on the mounting plate. •Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela Finally,attach the horn,strobe or horn/strobe to the mounting plate .Outdoor wall and ceiling products by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the •Outdoor products rated from—40°to 151°F mounting plate's terminals.The device will temporarily hold in place .Minimal intrusion into the back box with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: •Horn rated at 88+dbA at 16 volts •12 or 24 volts •Rotary switch for tone selection •At 24 volts,15,15/75,30,75,95,110,115,135,150,177 or 185 •3 horn volume settings candela by way of rear-mounted slide switch and front viewing window •Electrically compatible with existing SpectrAlert products •Horn tones and volume by way of rotary switch The SpectrAlert Advance series includes outdoor notification Agency Listings appliances.Outdoor strobes and horn/strobes(two wire and four 3 SIGNALING wire)are available for wall or ceiling.Outdoor horns are available for T 7125-1653:186 CIAO=strobes) wall only.All System Sensor outdoor products are rated between �� MEA 7125-1653:187(and=swbes) 7125.1653 188(MOrNnmbes) minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or approved ,r 7125-1653189(h°rns) 9 9 LISTED APPROVED I1 dry applications. SpectrAlert Advance Specifications • ArchitectF ngineer Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 11-inch back box,4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 1k-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync Circuit Module,12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30,75,95,110,115, 135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 49(6 x 4916 x 216-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) K Series Operating Temperature —40°F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V(12V nominal)or 16 to 33V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8-diameter x 2.5-high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.7W x 2.5°D(142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7W x 1.3"D(142 mm L x 119 mm Wx33 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12V nominal only for 15 and 15/75 cd. ti 605 0395-002 • UL Current Draw Data UL Max.Strobe Current Draw(mA RMS); UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-wire Horn/Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-wire Hom/Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Horn Tones and Sound Output Data Rotary Horn and Hom/Strobe Switch Settings Horn and Nom/Strobe Output(dBA) Setting Repetition Rate dB Level Switch 8-17.5 Volts 16-33 Volts 1 Temporal horn High Position Sound Pattern dB DC FWR DC FWR 2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 Non-temporal High 82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7" Externally coded High 6 Non-temporal Low 75 75 81 81 8* Externally coded Medium 7" Coded High 82 82 88 88 9" Externally coded Low 8" Coded Medium 78 78 85 85 9" Coded Low 75 75 81 81 "Settings 7,8,and 9 are not available on 2-wire horn/strobe. A05-0395-002 SpectrAlert Advance Dimensions 4.7" iii 6.8„ ..,...„ 1�_�I Dia. ier--- \ T--- -- ®� Q ;' 1II 2.5_ ,\,___ ___) 5.6" Ili) II . , j7=7=2_,=',® 14-2.5=4- SpectrAlert Advance Ordering Information Model Description Model Description . Wall Horn/Strobes Ceiling Horn/Strobes(cont'd.) P2R" 2-wire Horn/Strobe,Standard cd*,Red PC2Wt 2-wire Horn/Strobe,Standard cd,White P2RH` 2-wire Horn/Strobe,High cd,Red PC2WH" 2-wire Horn/Strobe,High cd,White P2RK• 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red P2RHK" 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4-wire Horn/Strobe,High cd,Red - P2 • 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH" 2-wire Horn/Strobe,High cd,White PC4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor P4R• 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White . P4RH` 4-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR" Strobe,Standard cd,Red P4 • 4-wire Horn/Strobe,Standard cd,White SCRH" Strobe,High cd,Red P4WH• 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wall Strobes SCRHK Strobe,High cd,Red,Outdoor SR" Strobe,Standard cd,Red SCWr Strobe,Standard cd,White SRH" Strobe,High cd,Red SCWH•5 Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH' Strobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R" 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH` 2-wire Horn/Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Ceiling,White Notes: `Add"-P"to model number for plain housing(no'FIRE'marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g,P2R-SP *"High cd"refers to strobes that include 135,150,177,and 185 candela settings."Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. ��� SYSTEM 02006*S`M Sens... 3825 Ohio Avenue•St.Charles,IL 60174 r,oa,rcwK ions+ aaa�yr c +rn� ;om+a --- SENSOR Phone:800-SENSOR2•Fax:630-377-6495 ""eg product"forr'"`°" dnq the W"`M'�'a""da" " A05-0395002.7/06.11659 • FIRE SYSTEM ACCESSORY Firepower 5495 N Distributed Power Module iiiii n) .. _ . .„..,..:,,... ..:„:„..2,,,.., i.:43 , rte .E �'�'' �, In an emergency, you need maximum power. t3 n,. -, g The Firepower 5495 Distributed Power Module by Silent Knight is the most- , ;, j4• i •,�, '+=powerful and cost-effective power supply available today. It delivers 6 amps of•I,. -i ' notification appliance circuit power and built-in synchronization for appliances from System Sensor',Gentexo, Wheelock and Faraday—what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And,ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5495. Call Silent Knight today for more information at 1-800-446-6444. Firepower 5495 • Independent trouble relay resistors provided. Since the 5495 Distributed Power Module • AC loss delay option shuts off power draws very little power from the control, • The firepower 5495 is a 6 amp to non-essential high-current it is possible to connect one Firepower notification power expander that accessories like magnetic door 5495 to each notification circuit on the provides its own AC power connection, holders control panel and still provide full battery charging circuit, and backup • Built-in synchronization for supervision of the notification circuits all battery for use with fire and security appliances from System the way back to the control panel. controls such as the Silent Knight Sensore,Gentex®, Wheelock and Model 5208 Fire Control Faraday /Communicator. The 5495 is the cost- solution for powering Stand alone operation. notification appliances required by the • Lightweight design adds to ease of .�'iT ,` *ii �z, _� 41.-ate Americans with Disabilities Act (ADA). installation and reduces shipping p, F '.-r+,,,,. 'aLa^ %w'"�* The 5495 has built-in ANSI cadence costs ,,*, &'"tom , „1 �Y° ,',.:',-4;,,4- pattern, which can upgrade older • Operates with most polarized, UL ,,-4‘, , „a{, .4 �t ii control panels that lack cadence Listed notification devices f7 � '• "�~ »r� s capability. • UL 864 & 1481 listed t � w r ', , -. r.:6 z_ b:,: ?z .<�.,•. - Features • CSFM approved x{ rf x'� � .. , "' ,, ,�►r— '4 • UL Listed for 6 amps of notification 1 ,``� ;. power • ANSI Cadence pattern output '�' . �" i capability built-in - .t ,s= ., r- w�, • Power supply's advanced switch 1:� mode design reduces damaging Connection to Local Fire Control f` x . �'-. -' heat and manages power up to 50% Firepower 5495 may be connected to a `Ir x .r ` ` 5,~ '" ,"'" s*r more efficiently than other systems local fire control which utilizes Class A ' • Dip switches allow for easy or Class B type notification circuits ''''' ' reconfiguration operating between 9 and 32 VDC. The nK,rc"c,ir - • 24 VDC filtered output voltage control panel's notification circuit is • Four power-limited notification connected to one of the inputs on the outputs, 2 Class A or 4 Class B, or 1 5495.The control panel's notification Firepower 5495 circuit end-of-line resistor is also Class A and 2 Class B Distributed Power Module • Additional continuous auxiliary connected across two terminals on the Firepower 5495, which provides output supervision between the 5495 and the • 3 amps per output circuit fire control panel. Polarized audible SILENT • 2 inputs; 2 Class B or 2 Class A and/or visual notification devices are KNIGHT - 10• Ground fault detector/indicator then connected to the 5495 signal circuits using the 4.7kS2 end-of-line ARE SYSTEM ACCESSORY . Firepower 5495 Distributed Power Module ril Supervision Current: Input Firepower 5495 supervises a Standby 75 mA voltage range: 9 - 32 VDC variety of functions including: Alarm 175 mA Battery charging • Low AC power. Auxiliary capacity: 33.0 AH • Low battery condition. power circuit: 1 Ambient Temp.: 32° to 120° F • Earth ground fault. Notification 0° to 49° C • Auxiliary output power limit circuits: 4 Mechanical condition. Output Dimensions: 12.25"W x 16" H x • EOL supervision trouble or configuration: 2 Class A(Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output. (1 Class A& 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights Firepower 5495 creates a trouble Amps per AC power on : Green condition on the host control signal circuits to which it is connected. output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow Firepower 5495 still maintains the Notification Ground fault: Yellow ability to be activated by the host circuit output: 20.4 to 27.3 VDC control. In addition, the 5495 @ 3.0 amps each, Aux Trouble: Yellow • provides a Form C trouble relay 4.7 k) EOL Output output as an alternative to using resistor required troubles (1-4): Yellow the notification circuit trouble. on each Class B Approvals: . Electrical Specification circuit UL: 864 & 1481 AC Input: 120 VAC at 2 amps No. of inputs 2 NFPA: 72 Output: 24 VDC at 6 amps Input CSFM . configuration: 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC _ Aux.Power I Trouble Output Local Fire Control (Alternative to notification circuit trouble.) 4 SILENT KNIGHT e 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 763-493-6435 FORM#350395, Rev.04/02 FAX: 763-493-6475 World Wide Web: http://www.silentknight.com Copyright©2002 Silent Knight _ ____ . ______________________---- genesis® Ah • eSJs t4 -,212V, �.� '� NP MUD REdUR6FA 1E uabRCm HTrE•r g y\ yam_ � • _ b : �...., Pb '"' 4 :> ENERSYS a.EM... N P 7- 12 t — NP7- 12FR Sealed Rechargeable rte* r .__ r, Lead-Acid Battery •NOMINAL VOLTAGE: 12V •CHARGE RETENTION(shelf life) 12 V 7.0A I) at 68.F(20"C): •NOMINAL CAPACITY: 1 month 97% 20 hr.rate of 0.35A to 10.5V 7.0Ah 3 months 91% 10 hr.rate of 0.65A to 10.5V 6.5Ah 6 months 85% Terminal 5 hr.rate of 1.19A to 10.2V 5.95Ah 1 hr.rate of 4.20A to 9.60V 4.2Ah •LIFE EXPECTANCY: .185±A04 STANDBY USE 3 to 5 years •WEIGHT(approx.): 6.17 pounds CYCLE USE (approx.): 1- 11 1 .060 DM (2.80 kgs.) 100%depth of discharge 250 cycles -1 50%depth of discharge 550 cycles MINS .. n •ENERGY DENSITY(20 hr.rate): 30%depth of discharge 1200 cycles o $ 1 Nil — — 1.49 WH/cubic inch(91.0 WH/liter) •SEALED CONSTRUCTION: f INCH =MM • •SPECIFIC ENERGY(20 hr.rate): Can be operated in any position _ .250 6.35 13.6 WH/pound(30 WH/kg) without leakage. I .185 4.70 .124 3.15 •INTERNAL RESISTANCE OF CHARGED •STANDARD TERMINAL: .098 2.49 BATTERY: Quick Disconnect.187 .031 ±004 30 milliohms(approx.) or Optional.250 .060 1.52 .031 0.79 •MAXIMUM DISCHARGE CURRENT •HOUSING MATERIAL: ABS Resin .020 0.51 WITH STANDARD TERMINALS: .004 0.10 • 40 amperes •OPTIONAL: Container and cover made from •MAXIMUM SHORT-DURATION Flame Retardant ABS DISCHARGE CURRENT: (UL94-V0/L.O.I.>28%) Dimensions 210 amperes •OPERATING TEMPERATURE RANGE: CPO _ !/�.1/ CHARGE 5°F to 122°F DISCHARGE -4°F to 140°F 1.56±0.1A) (-20°C to 60°C) ±1 ---_ 595± I aR t g a ''' ; - DIMENSIONS:MM(INCHES) "• ' UL listing pending-File No MH16464 EnerSys TM Power/Fu// Solutions Publication No:US-NP7-12-02•July 2005