Permit CITY OF TIGARD MASTER PERMIT 14 1. . COMMUNITY DEVELOPMENT Permit#: MST2014 00137 T t C AR O 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/15/2014 Parcel: 1S125DCO2200 Jurisdiction: Tigard Site address: 7005 SW VENTURA DR Subdivision: WASHINGTON SQUARE ESTATES Lot: 12 Project: Wilkerson Project Description: Repair of existing foundation BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $5,400.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: KW REAL ESTATE CONSTRUCTION RAMJACK OF SOUTHERN OREGON LLC Required Items and Reports(Conditions) &INVESTMENT INC PO BOX 11701 12855 SW GLACIER LILY CIR EUGENE,OR 97440 TIGARD,OR 97223 PHONE: 503-539-1670 PHONE: 541-688-7177 FAX: Total Fees: $297.98 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a ••4 es or direct questions to OUNC by cal'ng 5 3.2 .1987 or 1.800.332.2344. Issued By: ,- - r� 'e - -- Signature: A Ca `� FL' by 7:00 a.m.for the next available inspectio date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential RECEIVED FOR OFFICE USE ONLY 1,1 City of Tigard Date/13. a/-1 /el ( Q7 Permit No.: /f��1(J.zV/37 • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review u Phone: 503.718.2439 Fax: 503.598.10 G 2 1 2014 Date/By: /14/ Other Permit: I 1 G A K I) Inspection Line: 503.639.4175 Date Ready/By: ,...,,k/ orris: Fa See Page 2 for Internet: www.tigard-or.gov CITY OF 1 N�tified/Method: l Supplemental Information CITY CARD ` . ,/ TYP REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement RI Other: -..--o 3Lf j m m e .lY• equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $ f (4 '4 1-and 2-family dwelling El Commercial/industrial `! O El Accessory building El Multi-family Number of bedrooms: El Master builder El Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 7 oo5 34.) v e y`- y-cA New dwelling area: t C2 quare feet VP City/State/ZIP: T\`7�q O 9 722.3 Garage/carport area: ,) square feet Suite/bldg./apt.no.: Project name: Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. r-pa 1 oC nN! s-h- ^`Ec ^-i 1 Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Le r 11,x)+ \rt". I `1%�,�^s fjy� Type of construction: Address: j/ 2,8.5 51I.) at(C�(er CAy C�1,CCIA_, Occupancy groups: City/State/ZIP: -1-1 ' O 97 Existing: Phone: ) 53 .. 1 col0 Fax:( ) New: p APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* Business name: a m ar (Please refer to fee sit): le) tN; Structural plan review fee(or deposit): Contact name: OY�l FLS plan review fee(if applicable): Address: 95) .Bc4 v\C i �/' — City/State/ZIP: (5(2-. to-1 LI 0Z Total fees due upon application: c�� Amount received: t� Phone: "t! ) (Dss--"7 -1-7 Fax::(541)(o —4qc) 1 E-mail: ') v\TU Y f�l.yV\.\a_c .- DT_ Co tM PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTkACTOR roof-top mounted Photo Voltaic Solar Panel System. Business name: 1./1, , _ Submit two(2)sets of roof plan with connection details '/ and fire department access,along with the 2010 Oregon Address: \c B'v?� I l 70 I Solar Installation Specialty Code checklist. l T Permit Fee(includes plan review City/State/ZIP: — ���`L�/ and administrative fees $180.00 1 Phone:(54 U TpS5S -7 I77 Fax:(J,.(() (p —(4 clef ) State surcharge(12%of permit fee): $21.60 CCB lie.: I 4 (pet Du Total fee due upon application: $201.60 Authorized signature: /6/ lam" This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: fy� C n` - Date: Oil I 41 t IL/ *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB) From:Ramjack of Oregon 541 688 4991 10/01/2014 14:34 #358 P.001/006 RECEIVED OCT 1 2014 v,- 1 f BUILDING WINO J RAinn jam CCB # 146906 PO Box 11701 Eugene, OR 97440 Phone: 541-688-7177 or 866-4-RAMJACK Fax: 541-688-4991 To: J, From: Ram Jack Oregon Fax: c5 v'3 5 1 WPages: p Phone: .5y1-- ( O -7/77 Date: 10--/—11/ Re: ` r' �� �� CC: Attn:�"�"' 'f1 pt,teac (WA_ Vt.c.ica - 7o vs I2Cn_r . 01,1'u-e, J r'; 34wK,Or lacnut �vt �Ta01�- G�J 7 OneL !' 4 r, .- We Wi/I orotr"- LtkaiL a-40e- From:Ramjack of Oregon 541 688 4991 10/01/2014 14:34 #358 P.002/006 STARK 4001 Main Street, Suite 305 FOUNDATIONS Vancouver WA, 98663 P: 360.566.7343 September 26, 2014 Mr. Ken Marquardt Ram Jack of Oregon 850 Bethel) Drive Eugene, Oregon 97402 Re: Special Inspection—7005 SW Ventura Drive, Tigard, Oregon Permit No.: MST2014-00137 Dear Ken- I visited the site referenced above and have performed the special inspection of the installation of the helical tie-backs per ICC ESR-1854 and the load test on the helical tie-backs. Helical Anchor- Installation The pier used for installation was a 2-7/8"diameter pipe with a 10"diameter helix. The installation was performed by Ram Jack of Oregon, certified installers for Ram Jack products using a 7K drive head. The original design indicated a helical pier tie-back load requirement of 22,200 lbs working load. This was designed conservatively as there was no indication as to whether the wall was restrained or unrestrained. During the course of the repair work it was discovered that the wall is not only unrestrained but also the bottom of the wall is about 4 feet below the exterior grade. As a result the pressure on the wall is less than originally designed. The revised design based on the actual field conditions is attached and the helical pier tie-back requirement is 7,200 lbs working load (14,400 lbs ultimate). Tie-backs were installed to a depth of 24 to 28 feet at an installation angle of 25 to 35 degrees. A minimum installation pressure of 1,800 psi was achieved resulting in an ultimate load of 39,982 Ibs, exceeding the required ultimate load per the revised design. The attached drive logs indicate the depths and corresponding pressures recorded during installation. Helical Anchor—Load Testing Per the design requirement, one helical anchor was to be tested to 150%of the design load. The design load was to be sustained for a period of 5 minutes with the deflection requirement to be less than 1/8"displacement. The pier was loaded at 25%load increments until the 150%design load (10,830 lbs)was achieved. Each incremental load was sustained for two minutes with the displacement recorded at the end of the time period. The process was repeated until the 150%design load was achieved and sustained for five minutes with displacement recorded. The chart below gives the pressure, load, and subsequent displacement. A 7.22 square inch hydraulic cylinder and dial gage was used to perform the load test. Page 1 of 5 • From:Ramjack of Oregon 541 688 4991 10/01/2014 14:35 #358 P.003/006 STARK 4001 Main Street, Suite 305 FOUNDATIONS Vancouver WA,98663 P: 360.566.7343 Helical Anchor Load Test Load Increment Pressure(psis Load (Ibs) Displacement(in) 25% 350 2,527 0.005 50% 600 4,332 0.008 75% 750 5,415 0.012 100% 1000 7,220 0.020 150% 1500 10,830 0.031 At the end of the load test the pressure was released and the anchor rebounded to it's initial position with no recorded displacement. Summary Based on my special inspection and structural observation,the helical tie-backs were installed according to the engineering design load requirements and according to ESR-1854. Additionally, the load test validated the sufficiency of the piers to support the required load. Please give our office a call if you have any questions or need further assistance. Regards, ,>;() ..( PROFFss 4'I4OPE * Daniel Stark, P.E. . r / Stark Foundations, Inc. / Attachments: Drive Log V4/4)- 13 20°M Q- Helical Driver Torque Chart OIMELw EXP.: 06/30/16 Page 2 of 5 From:Ramjack of Oregon 541 688 4991 10/01/2014 14:35 #358 P.004/006 17•444,1%115, z I e-, fr,frr" / . lA-c5 1 v " COIX■0114.-wt - c-4,--e-Z i J.. A . i 1 Fs 1 .6 %4,.riajr- ..kr1./.2. 1-- ‘‘t 1 silli4v•r- V tc..1.--• ?of 4 1. 1 6co t :f I •- i ... . 1, ti ...... I 4.-A4 -,.1..... ._ ... . . , - A. .. --- --"-- ..... .... ... ...... .. .. . ... .. Alk• Vel7 C, 01 MU Z f. Z'-:. -1<ti.. 4t. ' '' I- • .4 . c r• (et 1 I.C i C/ears .%) "- 1 zoo... 6.•094-.L.:;-;)_ __ %., ... . ... 620 ( e, t - ri.v ... ... Ii.k.-.01b" • • • .• . . , : . . : . . . .........._._..,______•....... ......„., . ,....---A. . . • . . ' -1" • -0, wit /to . IP- i t: _alike?. : ..(w....1...;) . . .• . . , . • : - • . : . . • i . . • . . . . . . . . . . . . .• . • • .• . . . • • ..._........................_.... . •:. . . . . ... .. . : . • . . . . . : . . . . . • -.: : : .......... .. • : : -. • ......-r•-• ; . . ... • : • : , ' • . • ' i ' . ; -.. ..-...— --: - , . • : . : . . : . ' • : : • ' • • • • • . • • . . . , . . . : . : —.. . . t .. . ...• , • . . . . . • . . . . . . . . . . . : i : • . . . . • . . : . . : . ..„..._—_-....--:-..---......................... — . • . : : . • : : • : . , I . . : . . . . : : ..'.—.........................--....—t.......——........ ...... .. '. : . • . 1 . ' • • . . , . . _ .._ _ -- - ,.. I : i . t ; ; . : . : .• . , . :., . . . . i . t '-i- -i• . i . . . 3 1 .1 _1 I • 3. , :• . . • . . . • • . Page 3 of 5 Lo . _9 AJACK Foreman: Fredy Crew: Poncho Start Date: 9/8/2014 co M HELICAL PILE DRIVE LOG a ADDRESS: 7005 SW Ventura Dr. Tigard, OR OWNER: Kermit Wilkerson 1' K Drive Head Special Inspection Engineer: r, JOB # 014-187 Daniel Stark 360-566-7343 F I I r I r r T - 211' w Di w rn w 1 w (7 W V7 w . w a. rn a 17 o 0 a. 0 a O a O a. 0 a 0 a 0 a 0 a 0 a CV CD , 1 1d 5oG II 500 2z ?cc 221 1zfi. - 2 4 az 12 a -- , _1100 2f 1 100 Mtge 3 7 500 1a_ lam 13- ittio 22 r( 24 \tEco G , CD co co 1 C Q) a) �' o 4 0 U CCI Products Used: o 4551.78 Tie Back Assembly Other: 6140 8-10" ON 5' - 2 7/8" Other: 0 6106 5' Ext - 2 7/8" Other: From:Ramjack of Oregon 541 688 4991 10/01/2014 14:35 #358 P.006/006 HELICAL DRIVER TORQUE CHART Upgraded 7K Driver Dealer: Ram Jade Oregon RAMJACK 850 Bethel Drive Eugene,OR 97402 Torque Equation: Hydraulic Motor: T"(Pressure displacemenh Model: White 300200B7301AAAAB 24n Gear Ratto * motor j gear Displacement(in ); 12.5 where: Pressure= hydraulic pressure(psi) Gear Drive: displacement= hydraulic motor displacement(in 2) Model: Auburn 6SB1316F14 gmow = motor efficiency Ratio: 16.88 q gear = gear drive efficiency Torque Chart Pressure(psi) 500 750 1,000 1,250 1,500 1,750 2,000 2,250 2,5001 2,750 3,000 3,250 Torque(f-ibs) , 1,234 1,851_ 2,468 3,085 3,702 4,319_ 4,937 5,554 6,171__ 6,788 _ 7,405 8,022 "NOTE: The torque can also be calculated at any hydraulic pressure by multiplying the pressure by the psi/torque factor for this helical driver which is 2.468. Ultimate Capacity''' 2 3/8"dia.shaft(K, =10) 12,341 18,512 24,683 30,853 37,024 40,000' 2 7/8"dia.shaft(K, =9) 11,107 16,661 22,214 27,768 33,321 38,875 44,429 49,982 55,536 61,089 66,643 3 1/2"dia.shaft(K, =7) 8,639 12,958 17,278 21,597 25,917 30,236 34,556 38,875 43,194 47,514 51,833 56,153 *NOTE : I)Ultimate('apacity(Q,) Installation Torque(7)x Torque Correlation Factor(!:,). 2)Capacities shown in table assumes the pile is fully braced and has no eccentric loading. 3)A saf tty factor of 2 should be applied to the ultimate capacity to obtain the working load capacity. 4)Torque rating for 2 318"pile is 4,000 ft-lbs(1,621 psi) Page 5 of 5