Correspondence (3) [TKA} space planning/commercial renovation/ interior design/dental/medical April 30, 2012 City of Tigard Building Codes Division Attn: Dan Nelson, Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 Re: Building Permit BUP2012-00060 Hello Dan, Thank you for your plan review of this project. I received your letter sent April 25, 2012 and have listed below the questions followed by my responses and where to find the documented information. 3. The exits shall be one half the diagonal distance of the building. Response: See revised code summary plan on sheet INT 1.0. The required 2nd exit may not be less than 1/2 the diagonal distance of the non-sprinklered building. 4. Please provide 18" clearance on pull side of door at surgery, op1, op2 and op3. Response: See revised floor plan and door schedule on page INT 1.2. 5. Provide details for Nitrous Room. (Venting, wall listing, sprinkler head, door) Response: Venting - see plan note 14 on sheet INT 1.2. See also detail 9 on page A2. Wall listing - see wall types on sheet INT 1.1 See attached cut sheet: fire assembly 465.pdf. Sprinkler head - See plan note 14 on page 1.2. Fire sprinkler by deferred submittal. See project data deferred submittals on sheet INT 1.0. Door - see door schedule on sheet INT 1.2. Door 123 to be 1-hour fire rating. Please call if you have any questions. Thank you, Tara Cantrell Toni King & Associates tc @tonikingassociates.com 503-235-0243 x5# TONI KING & ASSOCIATES 330 SE MLK Blvd, Suite 350/Portland Oregon 97214 ph: 503 235 0243 /fx: 503 546 5698 [TKA] space interior planning/commercial design/dental/medical renovation/ April 30, 2012 City of Tigard Building Codes Division Attn: Dan Nelson, Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 Re: Building Permit BUP2012-00060 Hello Dan, Thank you for your plan review of this project. I received your letter sent April 25, 2012 and have listed below the questions followed by my responses and where to find the documented information. 3. The exits shall be one half the diagonal distance of the building. Response: See revised code summary plan on sheet INT 1.0. The required 2nd exit may not be less than 1/2 the diagonal distance of the non-sprinklered building. 4. Please provide 18" clearance on pull side of door at surgery, opt, op2 and op3. Response: See revised floor plan and door schedule on page INT 1.2. 5. Provide details for Nitrous Room. (Venting, wall listing, sprinkler head, door) Response: Venting - see plan note 14 on sheet INT 1.2. See also detail 9 on page A2. Wall listing - see wall types on sheet INT 1.1 See attached cut sheet: fire assembly 465.pdf. Sprinkler head - See plan note 14 on page 1.2. Fire sprinkler by deferred submittal. See project data deferred submittals on sheet INT 1.0. Door - see door schedule on sheet INT 1.2. Door 123 to be 1-hour fire rating. Please call if you have any questions. Thank you, Tara Cantrell Toni King & Associates tc @tonikingassociates.com 503-235-0243 x5# TONI KING & ASSOCIATES 330 SE MLK Blvd, Suite 350 / Portland Oregon 97214 ph: 503 235 0243 /fx: 503 546 5698 BXUV.U465-Fire Resistance Ratings-ANSUUL 263 http://database.ul.com/cgi-bin/ulweb/LISEXT/1FRAME/FireResistanceW... Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings -ANSI/UL 263 Design No. U465 July 13, 2011 Nonbearing Wall Rating — 1 HR. 0 • ....•„< -c'_ ...a.L Y- '-'. '..'Y-_ .:'rnnv�'�':P. _'J^C:. A,- ,:`_rte ;. F rr;. - - ^'fV'' MF - .• ...4. !r J ti i ' 1 1. Floor and Ceiling Runners—(not shown) —Channel shaped runners, 3-5/8 in. deep (min), 1-1/4 in. legs, formed from min No. 25 MSG galv steel. attached to floor and ceiling with fasteners spaced 24 in. OC max. 1A. Framing Members*—Floor and Ceiling Runners— (Not shown) —As an alternate to Item 1 - Channel shaped, min 3-5/8 in. deep, attached to floor and ceiling with fasteners 24 in. OC. max. ALLSTEEL & GYPSUM PRODUCTS INC—Type SUPREME Framing System CONSOLIDATED FABRICATORS CORP, BUILDING PRODUCTS DIV—Type SUPREME Framing System QUAIL RUN BUILDING MATERIALS INC—Type SUPREME Framing System SCAFCO STEEL STUD MANUFACTURING CO —Type SUPREME Framing System STEEL CONSTRUCTION SYSTEMS INC—Type SUPREME Framing System UNITED METAL PRODUCTS INC—Type SUPREME Framing System I 01.9 8/18/2011 1:08 PM BXUV.U465 -Fire Resistance Ratings-ANSI/UL 263 http://database.ul.com/cgi-bin/uiweb/LISEXT/1FRAME/FireR q stanceW... 1B. Framing Members* - Floor and Ceiling Runners— Not shown- In lieu of Item 1 — For use with Item 2B, proprietary channel shaped runners, 1-1/4 in. wide by min 3-5/8 in. deep fabricated from min 0.020 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. CRACO MFG INC —SmarterTrack20TM, SmartTrack20TM MARINO/WARE, DIV OF WARE INDUSTRIES INC—Viper20STM Track, Viper20DTM Track TELLING INDUSTRIES L L C—Vper20STM Track, Viper20DTM Track 1C. Floor and Ceiling Runners — (Not shown)—For use with Item 2C- Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, min depth to accommodate stud size, with min 1 in. long legs. attached to floor and ceiling with fasteners spaced max 24 in. OC. 1D. Framing Members*—Floor and Ceiling Runners— Not shown- In lieu of Items 1 through 1C— For use with Item 2D and 4G only, proprietary channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. CLARKWESTERN BUILDING SYSTEMS INC—CW ProTRAK DIETRICH INDUSTRIES INC— DIETRICH ProTRAK DMFCWBS L L C—ProTRAK MBA BUILDING SUPPLIES— ProTRAK SOUTHEASTERN STUD& COMPONENTS INC— ProTRAK 1E. Framing Members*— Floor and Ceiling Runners— Not shown- In lieu of Items 1 through 1D— For use with Item 2E and 41 only, proprietary channel shaped runners, 1-1/4 in. deep by min 3-5/8 in. wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. TELLING INDUSTRIES L L C—TRUE-TRACKTM 2. Steel Studs—Channel shaped, 3-5/8 in. deep (min), formed from min No. 25 MSG galv steel spaced 24 in. OC max. Studs to be cut 3/4 in. less than assembly height. 2A. Framing Members*—Steel Studs—As an alternate to Item 2 - Channel shaped studs, min 3-5/8 in. deep, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height. ALLSTEEL & GYPSUM PRODUCTS INC—Type SUPREME Framing System 2 of 9 8/18/2011 1:08 PM