Correspondence (3) [TKA} space planning/commercial renovation/
interior design/dental/medical
April 30, 2012
City of Tigard Building Codes Division
Attn: Dan Nelson, Senior Plans Examiner
13125 SW Hall Blvd., Tigard, OR 97223
Re: Building Permit BUP2012-00060
Hello Dan,
Thank you for your plan review of this project. I received your letter sent April
25, 2012 and have listed below the questions followed by my responses and
where to find the documented information.
3. The exits shall be one half the diagonal distance of the building.
Response: See revised code summary plan on sheet INT 1.0. The required 2nd
exit may not be less than 1/2 the diagonal distance of the non-sprinklered
building.
4. Please provide 18" clearance on pull side of door at surgery, op1, op2 and
op3.
Response: See revised floor plan and door schedule on page INT 1.2.
5. Provide details for Nitrous Room. (Venting, wall listing, sprinkler head, door)
Response: Venting - see plan note 14 on sheet INT 1.2. See also detail 9 on page
A2. Wall listing - see wall types on sheet INT 1.1 See attached cut sheet: fire
assembly 465.pdf. Sprinkler head - See plan note 14 on page 1.2. Fire sprinkler
by deferred submittal. See project data deferred submittals on sheet INT 1.0.
Door - see door schedule on sheet INT 1.2. Door 123 to be 1-hour fire rating.
Please call if you have any questions.
Thank you,
Tara Cantrell
Toni King & Associates
tc @tonikingassociates.com
503-235-0243 x5#
TONI KING & ASSOCIATES
330 SE MLK Blvd, Suite 350/Portland Oregon 97214 ph: 503 235 0243 /fx: 503 546 5698
[TKA] space
interior planning/commercial design/dental/medical renovation/
April 30, 2012
City of Tigard Building Codes Division
Attn: Dan Nelson, Senior Plans Examiner
13125 SW Hall Blvd., Tigard, OR 97223
Re: Building Permit BUP2012-00060
Hello Dan,
Thank you for your plan review of this project. I received your letter sent April
25, 2012 and have listed below the questions followed by my responses and
where to find the documented information.
3. The exits shall be one half the diagonal distance of the building.
Response: See revised code summary plan on sheet INT 1.0. The required 2nd
exit may not be less than 1/2 the diagonal distance of the non-sprinklered
building.
4. Please provide 18" clearance on pull side of door at surgery, opt, op2 and
op3.
Response: See revised floor plan and door schedule on page INT 1.2.
5. Provide details for Nitrous Room. (Venting, wall listing, sprinkler head, door)
Response: Venting - see plan note 14 on sheet INT 1.2. See also detail 9 on page
A2. Wall listing - see wall types on sheet INT 1.1 See attached cut sheet: fire
assembly 465.pdf. Sprinkler head - See plan note 14 on page 1.2. Fire sprinkler
by deferred submittal. See project data deferred submittals on sheet INT 1.0.
Door - see door schedule on sheet INT 1.2. Door 123 to be 1-hour fire rating.
Please call if you have any questions.
Thank you,
Tara Cantrell
Toni King & Associates
tc @tonikingassociates.com
503-235-0243 x5#
TONI KING & ASSOCIATES
330 SE MLK Blvd, Suite 350 / Portland Oregon 97214 ph: 503 235 0243 /fx: 503 546 5698
BXUV.U465-Fire Resistance Ratings-ANSUUL 263 http://database.ul.com/cgi-bin/ulweb/LISEXT/1FRAME/FireResistanceW...
Fire Resistance Ratings - ANSI/UL 263
See General Information for Fire Resistance Ratings -ANSI/UL 263
Design No. U465
July 13, 2011
Nonbearing Wall Rating — 1 HR.
0
•
....•„< -c'_ ...a.L Y- '-'. '..'Y-_ .:'rnnv�'�':P. _'J^C:. A,- ,:`_rte ;. F rr;. - - ^'fV''
MF -
.• ...4. !r
J ti i
' 1
1. Floor and Ceiling Runners—(not shown) —Channel shaped runners, 3-5/8 in. deep (min), 1-1/4 in.
legs, formed from min No. 25 MSG galv steel. attached to floor and ceiling with fasteners spaced 24 in.
OC max.
1A. Framing Members*—Floor and Ceiling Runners— (Not shown) —As an alternate to Item 1 -
Channel shaped, min 3-5/8 in. deep, attached to floor and ceiling with fasteners 24 in. OC. max.
ALLSTEEL & GYPSUM PRODUCTS INC—Type SUPREME Framing System
CONSOLIDATED FABRICATORS CORP,
BUILDING PRODUCTS DIV—Type SUPREME Framing System
QUAIL RUN BUILDING MATERIALS INC—Type SUPREME Framing System
SCAFCO STEEL STUD MANUFACTURING CO —Type SUPREME Framing System
STEEL CONSTRUCTION SYSTEMS INC—Type SUPREME Framing System
UNITED METAL PRODUCTS INC—Type SUPREME Framing System
I 01.9 8/18/2011 1:08 PM
BXUV.U465 -Fire Resistance Ratings-ANSI/UL 263 http://database.ul.com/cgi-bin/uiweb/LISEXT/1FRAME/FireR q stanceW...
1B. Framing Members* - Floor and Ceiling Runners— Not shown- In lieu of Item 1 — For use with
Item 2B, proprietary channel shaped runners, 1-1/4 in. wide by min 3-5/8 in. deep fabricated from min
0.020 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max.
CRACO MFG INC —SmarterTrack20TM, SmartTrack20TM
MARINO/WARE, DIV OF WARE INDUSTRIES
INC—Viper20STM Track, Viper20DTM Track
TELLING INDUSTRIES L L C—Vper20STM Track, Viper20DTM Track
1C. Floor and Ceiling Runners — (Not shown)—For use with Item 2C- Channel shaped, fabricated
from min 20 MSG corrosion-protected or galv steel, min depth to accommodate stud size, with min 1 in.
long legs. attached to floor and ceiling with fasteners spaced max 24 in. OC.
1D. Framing Members*—Floor and Ceiling Runners— Not shown- In lieu of Items 1 through 1C—
For use with Item 2D and 4G only, proprietary channel shaped runners, 1-1/4 in. deep by min 3-5/8 in.
wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24
in. OC max.
CLARKWESTERN BUILDING SYSTEMS INC—CW ProTRAK
DIETRICH INDUSTRIES INC— DIETRICH ProTRAK
DMFCWBS L L C—ProTRAK
MBA BUILDING SUPPLIES— ProTRAK
SOUTHEASTERN STUD& COMPONENTS INC— ProTRAK
1E. Framing Members*— Floor and Ceiling Runners— Not shown- In lieu of Items 1 through 1D—
For use with Item 2E and 41 only, proprietary channel shaped runners, 1-1/4 in. deep by min 3-5/8 in.
wide fabricated from min 0.018 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24
in. OC max.
TELLING INDUSTRIES L L C—TRUE-TRACKTM
2. Steel Studs—Channel shaped, 3-5/8 in. deep (min), formed from min No. 25 MSG galv steel
spaced 24 in. OC max. Studs to be cut 3/4 in. less than assembly height.
2A. Framing Members*—Steel Studs—As an alternate to Item 2 - Channel shaped studs, min 3-5/8
in. deep, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height.
ALLSTEEL & GYPSUM PRODUCTS INC—Type SUPREME Framing System
2 of 9 8/18/2011 1:08 PM