Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT s . COMMUNITY DEVELOPMENT Permit#: FP52014-001417 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/04/2014 Parcel: 1 S135BA00102 Jurisdiction: Tigard Site address: 10114 SW WASHINGTON SQUARE RD Project: Pieology Subdivision: OAKBURG Lot: 9 Project Description: Fire sprinkler-modification of(22)fire sprinkler heads for TI Contractor: WYATT FIRE PROTECTION INC. Owner: PPR SQUARE TOO LLC 9095 SW BURNHAM PO BOX 847 TIGARD, OR 97223 CARLSBAD,CA 92018 PHONE: 503-684-2928 PHONE: FAX: 503-684-9657 FEES Description Date Amount Specifics: Permit Fee-COM 09/04/2014 $123.72 12%State Surcharge-Building 09/04/2014 $14.85 Type of Use: COM Plan Review-Fire Life Safety-COM 09/04/2014 $49.49 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 09/04/2014 $8.00 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Sprinkler Type: Standpipe Required: Hazard: Density: 0 Design Area: 0 K Factor: 0 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $196.06 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $4,421.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the r, - adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You m obt-'n a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.:•1.332.2344. Issued By: Permittee Signature: Ain i (.4 I Call 51. OF 39.4175 by 7:00 a.m.for the next available inspection da :� This permit card shall be kept in a conspicuous place on the job site until complet• of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System REC b FOR OFFICE USE ONLY City of Tigard Received � l ,J' PermitNo.: Date/By:13125 SW Hall Blvd,Tigard,OR 2 7 2 Old Plan Review �/ ■ 59 ./y Other Permit: AAP °t I:1�/77 Phone: 503.718.2439 Fax: 503. 1960 Die/By, TIGARD I ton Line: 503.639.4175 r(�,� to type Date Read /B J Juris: ® See Page 2 for Internet: www.tigard-or.gov Va�`^ �I`^��� Notified/Method:1/�/�Li �� " I Supplemental Information LOINS ON s w .�` ;-f�. 64.1 L,ley/ TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑ Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1-and 2-family dwelling ®Commercial/industrial Valuation: $ ❑Accessory building ❑Multi-family Number of bedrooms: ❑ Master builder ❑Other: umber of bathrooms: JOB SITE INFORMATION AND LOCATION : lumber number of floors: Job site address:10114 SW Washington Sq Rd New dwelling area: square feet City/State/ZIP:TIGARD,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.:A06 Project name:PIEOLOGY Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.:1S135BA00102 Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. FIRE SPRINKLER ADD/RELOCATE FOR TENANT IMPROVEMENT Valuation: $4421.00 Existing building area: square feet New building area: 0 square feet ❑ PROPERTY OWNER ❑ TENANT Number of stories: 1 Name: Type of construction: Address: Occupancy groups: City/State/ZIP: Existing: LIGHT/ORDINARY Phone:( ) Fax:( ) New: LIGHT/ORDINARY Z APPLICANT ® CONTACT PERSON NOTICE Business name:Wyatt Fire Protection All contractors and subcontractors are required to be Contact name:Ashley Payne licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address:9095 SW Burnham Rd jurisdiction in which work is being performed.If the City/State/ZIP:Tigard,OR 97223 applicant is exempt from licensing,the following reasons apply: Phone:(503)684-2928 Fax::( ) E-mail:a.payne @wyattfire.com CONTRACTOR BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:Wyatt Fire Protection Permit fee: Address: State surcharge(12%of permit fee): City/State/ZIP: FLS plan review(40%of permit fee): Phone:( ) rax:( ) (Due upon application.) CCB lie.:64077 Total permit fees: Authorized signature: Amount received: permit application expires if a permit is not obtained Print name:Ashley Payne Date:8/26/14 within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Service Board I:U Building'Permits\FPS-PermitApp.doc Rev 01ro52012 4404613T(t t/02/COM/WEB) City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information Describe work to be done: 1.) ❑ New 2.) Modification to sprinkler heads only: ® Addition El 1-10 heads: No plan review required. ® Alteration ® 11+ heads: Plan review required. El Repair Number of sprinkler heads: 22 Additional description of work: Type of System (Complete A, B, C or D as applicable): A.) Commercial Sprinkler (0 Wet ❑ I)ry Additional Standpipes Information: Hazard Group LIGHT/ORDINARY 1 Density 0.10/0.15 Design Area 1000/1500 K. Factor 5.6 Sprinkler Project Valuation: $ 4421.00 B.) Type I- Hood Fire Suppression System Hood Project Valuation: $ C.) Fire Alarm Submittal shall Battery Calculations ❑ Yes include: Individual Component ❑ Yes Cut Sheets Fire Alarm Project Valuation: $ D.) Residential Sprinkler (Stand Alone System) Square Footage: Permit Fee: 0 to 2,000 $198.75 2,001 to 3,600 $246.45 3,601 to 7,200 $310.05 7,201 and greater $404.39 Sprinkler Project Square Footage: sq. ft. Fire Protection Permit Fees Project valuation subtotal (see A, B & C above): $ Permit fee based on project valuation (see fee schedule): $ Permit fee based on square footage (see D above): $ State Surcharge (12%of permit fee): $ FLS Plan Review (40% of permit fee): $ TOTAL: $ Plan review requires a completed application and three (3) sets of plans at submittal. Plan review fees are required at submittal. C:\Users\Wyatt Fire\Documents\PemtitApps\PieologyWashSquare8.26.14.doc Rev 018/5/2012 RECEIVA AUG 2 7 = • •• •• ••' ITYOF- I KAH WYAT UIL y rtnco4 .._ • FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 PIEOLOGY WASHINGTON SQUARE 10114 SW Washington Square Road • Tigard, OR 97223 OFFICE COPY CITY OF TIGARD REVIEWED FOR OAR CODE COMPLIANCE Approved: [X! OTC: [ J Permit#: Ff ZG/L/—c0 /410 Address: /Girl'/ St l kms ft,&(a,t+h) S Q Suite #: By: Date: g• Z •/y )hl FIRE PROTECTION EQUIPMENT SUBMITTAL tqco Worldwide Fire Protection Contacts www.tyco-fire.com Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE . . .- The TYCO Series TY-FRB Sprinklers ''re' ' Description described herein must be installed and _ maintained in compliance with this doc- ' - " The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable Upright(TY313)and Pendent(TY323) standards of the National Fire Protec- 1 lirrAl Sprinklers described in this data sheet tion Association,in addition to the stan- , '!' J are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair ' sprinklers designed for use in light or the performance of these devices. '= ___. ordinary hazard,commercial occupan- cies such as banks, hotels,and shop- The owner is responsible for maintain- ping malls. ing their fire protection system and - devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble,is intended for use in areas with a any questions. finished ceiling.This recessed pendent ) sprinkler uses one of the following: •IL�,-�► • A two-piece Style 15 Recessed Sprinkler Escutcheon with recessed adjust- Identification /� f . ment up to 5/8 inch (15,9 mm)from 1e ,4 the flush pendent position. Number (SIN) - • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT V. the flush pendent position. The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Approvals 175°F(79°C) Intermediate level versions of Series 200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM,LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler:Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)* Button Brass/Copper *The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (1.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi1t2(80,6 LPM/bar""2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* k — 7 / l-G,` Y d . I ---- / 7/16' I _ (11,1 mm) 1 1■F 4 NOMINAL 2" (70 I NI W MAKE-IN (50,8 mm) I NI NI p', a 2" 1-3/8„ 3 t t (50,8 mm) _ (34,9 mm) I ir li WRENCH I 1 FLATS t 1/2"NPT** DEFLECTOR* Imo— 2-7/8"(73,0 mm)DIA. --- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE cc, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. ,./ih- glass bulb, allowing the sprinkler to General Instructions FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally,a small air bub- Criteria ble should be present. The diameter WRENCH of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) ���>r Sprinklers are intended for fire protec- temperature ratings. e tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min- Approval agency(such as, UL Listing imum to maximum torque of 7 to 14 is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels ....- 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening the sprinkler. Re-adjust the position of FIGURE 3 the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8"DIA sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1,apply the W-Type 6 2-1/4"DIA. Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15,9 mm) Recessed Pendent Sprinklers i \ - FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" 1 Sprinklers must be installed in accor- (9,5±7,9 mm) AUL j iv% 1 f dance with the following instructions. i Step A.After installing the Style 15 or MOUNTING '-� 1/8" Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread -----— I sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE sprinkler fitting. 3/a"(19,1 mm) Step B.Tighten the sprinkler into the FIGURE 4 sprinkler fitting using only the W-Type SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) 7 Recessed Sprinkler Wrench (Figure WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. — sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF Step C.After ceiling installation and fin- SPRINKLER 2-1/4"DIA. fishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) -' Closure over the Series TY-FRB Sprin- 5/16±1/4' 1/2"(12,7 mm) kler and push the Closure over the (7,9±6,4 mm) Mounting Plate until its flange comes in I IN FLUSH contact with the ceiling. 1 _: AzaL I Care and t I MOUNTING ` 1/8" Maintenance SURFACE (32 mm) The TYCO Series TY-FRB,5.6 K-factor, --'- I Upright(TY313)and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. if they cannot be completely cleaned Absence of the outer piece of an by wiping the sprinkler with a cloth or Automatic sprinkler systems are rec- escutcheon, which is used to cover ommended to be inspected, tested, • a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. klers are not used for hanging any after installation. Sprinklers damaged objects and that the sprinklers are only slippage, like,striking,ust be replaced. cleaned by means of gently dusting Also, replace any sprinkler that has a with a feather duster;otherwise, non- cracked bulb or that has lost liquid from operation in the event of a fire or inad- its bulb.(Ref.Installation Section.) vertent operation may result. Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro- inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document,as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the • TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX I L SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2-NPT) TY313 3 PURE WHITE(RAL9010)°° 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2-NPT) TY323 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER •Use suffix•I"for ISO 7-1 connection; 9 CHROME PLATED 200 200`F(93°C) for example.77-370-4-175-I Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6,Quick Response,(specify)tem- perature rating, (specify) finish, P/N (specify,refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify)finish,P/N(specify*) Specify: Style 20 Recessed Escutch- eon with(specify*)finish,P/N(specify*) •Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. two TEFLON is trademark of The DuPont Corporation. Fire Protection Products Dyna-Thread® - M-COAT® Submittal Data Sheet ® Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread"—M-Coat' sprinkler pipe represents an engineering NPs Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior 1" 1 080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — 11/4" 1.408 1.870 2.54 9.50 1.00 ® Comparison to Schedule 40 32 35.8 2.8 3.78 — — 1'/" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread—M-Coat`•inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 — — giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — — approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall 0 c UL thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— APPROVE M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread—M-Coat is protected by a clean,durable mill coating for 0 American Made extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight, Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA,Canada,Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed O Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread— use in wet systems.Dyna Thread—M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.0.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: P:allied Customer Service:(800)882-5543 Fax:(800)659-7730 ,n►,rvvt,.alliedtube-sprinkler.com 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT* Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 """'°`A F, 02013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301 A OD = . ,- -- •- -...,. 1111:1= .........''.., , ... ••, - 7-, /jr/i/ffI:li/ii/ [r V , f `y a1) l f//If,. • 4 ' I : i i. , i a. • , , , f: iin4 ,, 0 . ' ,-,' 4= '..- • , Cad Z 1:11::11 SMITH COO ER® I N T E R N A T I O N A L Ductile Iron Threaded Fittings Specifications • < branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • C ® US Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 41> • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 111111111L. 500 200 480 _250 460 300 440 I:350 h111111111 - ' 420 400 400 450 380 500 360 550 340 600 320 ,. 650 300 .,. s i 1 ucti e ron I,ttings- ass 1 1 1 / 1 QUALM FIBS C ® US APPROVED Fig. 35E 3- 90° Elbow LISTED A ` Size A Packing Weight , wi,..� Part Number 44. in in Inner Master lb 1 _ 111 ___i _ 1/2 3513004 1.13 100 200 0.2 -k\") 3/4 35E 3006 1.31 70 140 0.3 . i� A 1 35E 3010 1.50 40 80 0.5 1 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 ' 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B Packing Weight (-) Part Number g g 'k ': i,_.` in in in Inner Master lb ' '` . III 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 �� �A 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 -1' 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F3-45° Elbow r. Size Part Number A Packing Weight A in in Inner Master lb f i,- 1/2 35F 3004 0.88 150 300 0.2 fel 3/4 35F 3006 0.98 80 160 0.3 4‘ 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 - A 2 35F 3020 1.69 10 20 1.6 2-112 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size A Packing Weight Part Number in in Inner Master lb _��A 1/2 35T 3004 1.13 80 160 0.3 I��I 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 • � - 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-007b • FAX(323)890-4456 • www.smithcooper.com SC , 1 ucti e ron fittings- ass I I I ULttury vws c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED Size part Number A B C Packing Weight in Jul C in in in inner Master lb 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 t x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1 1-- I a 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 m! ---.■..arii II-1x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1x 3/4 x 3,'4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 B A 1x3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 • 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-112 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 r 1 1 -1/2 x 1-1/4 35R13014012 1.82 1.82 1.88 12 24 1.4 '__ a 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 '. ''i 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 °r4 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 t 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 , 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 c ; 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 U 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 ' 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size Part Number A B C Packing Weight J (Lt.- IC in in in in Inner Master lb 3!4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 all -^^ 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 A i B 1-1/4 x 1 x 1 1/2 35673012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 d1 Inch e ron ittings- ass I 1 ' t QUALM MIS C ® US APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number OEI A Packing Weight in in Inner Master Ib 1/2 35CP3004 138 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 • 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling is Size Part Number A Packing Weight in in Inner Master lb 0.3 A 1 x 1/2 35RC3010004 1.69 80 60 160 1 x 3/4 35RC3010006 1.69 120 0.4 0.6 !�', 1-1/4 x 3/4 35RC3012006 2.06 40 80 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35 H B3 -Hex Bushing ize Part Number A Packing Weight B in 1/2 in Inner Master lb 1 x 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 �-r-A S 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 D 2 x 1 35HB3020010 1.38 40 80 0.6 U 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 C 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 T I Fig. 35SP3 -Square Head Plug L E Size Part Number A Packing Weight .�-- in in Inner Master lb ���� 1/2 35SP3004 0.94 600 1200 0.07 . IA 3/4 35SP3006 1.12 350 700 0.1 -� 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 s Fig. 35U 3- Union with Brass Seat A Size A Packing Weight F.. in Part Number in Inner Master lb �.> mo1m 1 35U 3010 2.19 20 40 1.0 11111 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 unk. . 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com r- I. Ductile Iron Fittings- Class 300 UL/FM 1 QUALM Pull c ® uS APPROVED A A Fig. 35X 3- Cross LISTED Size A Packing Weight Part Number in in Inner Master lb �_���__ IA 1 35X 3010 1.50 20 40 0.9 1 I 1-1/4 35X 3012 1.75 12 24 1.4 1-1/2 35X 3014 1.94 8 16 1.8 , E4-4...cil A 2 35X 3020 _ 2.25 6 12 2.8 • B B Fig. 35RX3-Reducing Cross ` "- ` '`-' Size A B Packing Weight Part Number - v` TA in in in Inner Master lb '� 1-1/4x 1 35RX3012010 1.67 1.58 15 30 1.2 "III 111 1-1/2 x 1 35RX3014010 1.80 1.65 12 24 1.4 ^ IA 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 fm Fig. 35C3- Cap _ Size Part Number A Packing Weight I�\ in in Inner Master . I A 1/2 350 3004 0.87 300 600 0.1 I 3/4 35C 3006 0.97 200 400 0.1 1 350 3010 1.16 110 220 0.2 D 1-1/4 35C 3012 1.28 70 140 0.4 U 1-1/2 35C 3014 1.33 50 100 0.5 C 2 35C 3020 1.45 25 50 0.8 T 2-1/2 35C 3024 1.70 18 36 1.6 L E Fig. 35BC3-Beam Clamp �.d �� Size A Packing Weight A Part Number in in Inner Master lb _ ®%■ 3/8 35BC3003 0.75 100 200 0.3 Slam 1/2 35BC3004 0.75 80 160 0.5 iri SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 114 Pipe Hangers Fig. 200- "Trimline"" Adjustable Band Hanger (B-Line Fig.B317ONF) ®�'OLCO Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) c C us Fig.200C- "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig. 200S - "Trim line" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications • or Function: For fire sprinkler and other general piping purposes. Knurled _- v swivel nut design permits hanger adjustment after installation. Features: 1' 4. _ " • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe _ '� types and protect CPVC plastic pipe from abrasion.Captured design `y keeps adjusting nut from separating with hanger. Hanger is easily it B installed around pipe. :_ �' For hanger with non-captured nut order Fig. 200S. A . ,, • (21/2" (65mm)thru 8" (2oomm))Spring tension on nut holds it securely in ;f � ( ��;_;, hanger before installation.Adjusting nut is easily removed. /I t Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (200mm)) Fig.200-th.200-3/o in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8"(2oomm)), Fig.200-1t°zoo2 Fig.2002t/tt°20o0 Conforms to Federal Specifications WW-H-1 71 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) „r, Finish: Pre-Galvanized. Stainless Steel `'r t materials will be supplied with (2)hex nuts ,' ,1 in place of a knurl nut. 1 s f,` Order By: Figure number and pipe size 1 I 1 Designed to meet or exceed requirements of FM DS 2-0. Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 , Part No. in. (mm) in. (mm} in. (mm) lbs. (kg) /�"!'' 200-1/2 1/2" (15) 3/e"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) t 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-1114 11/4" (32) 3/8"-16 33/4" (94.0) 27/8 (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) • • 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" 165) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) -"` 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.61 29 (13.3) Fig.200S 200-31/2 31/2" (90) 318'-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/e-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by E:T•N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) �' B3205L - Threaded Rod (right& left hand threads) / n�0 Size Range: 3/8"-16 thru 3"-4 rod Spec Hilength \i1 Material: Steel j Function: Recommended for use as a hanger support in hanger assemblies. TL Rod is threaded on both ends with right hand threads of the length shown.Also available with left and right hand threads-specify Fig. B3205L when ordering. it�al Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number,rod size,length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) 83205-3/8 X'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25,93) 83205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 1112"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length .,4 \ Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length ����� Material: Steel 7�' H Maximum Temperature: 750°F(399°C) '� 9 `o Finish: Plain. Contact B-Line for alternative finishes and materials. y Order By: Part number,rod diameter and finish ts-Q Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/s"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 718"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 236 Revised 4.28/2014 B-Line by E:T•N VERTICAL MOUNT SAMMYS SAMMYS® for Wood Installs VERTICALLY into the bottom of wood structures easily and quickly! Not less than Wood Flooring 2'nominal width Product Features -1 2 4c20, •No � li Quick pre to ril install ng required.using the Sammy Not less than • 3•nominal Nut Driver with an 18V cordless Ihicbness(2-112') (depth or side drillidriver. of vertical^ember) °°erg " " " I / •Saves time from traditional Double SheeMOCk methods. For ve i cal use• Ceiling ins'.all in center of bower face. Reduces installation cost. G8n ma^.T erberirnen:ito base ma:eriai ke FfA13 anrnplarce, Composite I Truss •Made in the U.S.A. 1 CmsAt truss man:wfacturer for rerammencec.rstafahon po'nt. I. 'Pm ping may be requ,red h r 057 25380.Too/available on page 10. ■ i '■art Screw Ultimate UL Test FM Test Box Case ';'. ,. Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Qty Qty 114" 8002957 GST 100 114 x1" 210 (7118'OSB) 25 125 670 (314"%y) 1/4" 8003957 GST 200 114 x 2" 1760 (Fir) 25 125 1/4' 8004957 GST 300 1/4 x3' 2060 (Fir) 25 125 3 8" 8006957 GST.75 1/4 x 3/4' 564 (3/4"Ply) 25 125 Q. 3/8" 8007957 GST 10 1/4 x 1' 210 (7116'OSB) 300 25 125 670 (314'%y) _ ii Q 3 8" 8008957 GST 20 1/4 x 2" 1760(Fir) 850 1475 25 125 Q. 3/8" 8068925 GST 20-SS 1/4 x 2" 1760(Fir) 850 25 125 Q" 3/8" 8009925 GST 25.380 318x2-1/2" 2113 (Fir) 1500 25 125 Q-Q 3/8" 8010957 GST 30 1/4 x 3" 2060(Fir) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#81139 1 C. 318" 8011925 GST40 1/4x4' 2180(Fir) 25 125 — 318" 8012925 GST 60 1/4 x6' 2230 (Fir) 25 125 — 112' 8013925 GST 2 1/4 x 2" 1760(Fir) 25 125 1/2" 8014925 GST2.5-380 3/8x2-1/2' 2113 (Fir) 25 125 1/2" 8015925 GST 3 1/4 x 3" 2275(Fir) 25 125 — 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 1/2' 8017925 GST 6 1/4 x 6" 2230 (Fir) 25 125 _ #14 SW Red Nut Driver Part if 8114910 SAMMY Swivel Head) for Wood Installs VERTICALLY and swivels up to 17°in wood structure Product Features •Eliminates distortion of threaded rod. •Saves time from traditional methocs. 1 •Accommodates up to 3'/A"x 12 pitch roof. •Reduces installation cost. - •Allows 17°deflection from vertical. •Made in the U.S.A. 5 i.4 l+ Approvals Rod Part Model Screw LIMO, UL Test FM Test Min Box Case Size Number Descriptions Pullout�s) Load(Ibs) Load(Ibsj Thickness Qty Qty 4.4' 3/8" 8139957 SH-GST 20 1/4 x 2' 1257(Fir) 1050 1475 25 125 125 Q"Q 318" 8141957 SH-GST 30 114 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit orvnw.sammysuperscrew.com 4 rs VED RECEIVED r'viewed only as tc T,.rieni :fir triliia W:,1 nu t',n:ract&co io,„_;inn Intent. het...esirr r+:'t (•r • '1 ii•Pt co re9Nitent m V t] 2 7 . �! ::•:,,at,.r 214 j th :ih•: Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 10114 SW WASHINGTON SQUARE RD, TIGARD, OR, 97223 Commercial - Fire Protection System 999 Sprinkler final PASS - No C of O FPS2014-00140 Chip Barnett Violation Summary: Inspector Contractor