Loading...
Specifications PL/14203 -c761- 15 RECEIVED #1Io OCT 10 2013 CITY OFTIGARD LEDING DIVISION M A R K E T FOODS 85% Permit Documents Project Specifications WHOLE FOODS MARKET TENANT IMPROVEMENT Greenway Town Center Tigard, Oregon October 4, 2013 Cushing Terrell, Architects Engineers � j I u S I--� I N G 200 West Mercer Street, Suite 503 Seattle, Washington 98119 a TERRELL Ph: (206) 282-6222 ARCHITECTS ENGINEERS Fax: (206) 282-7350 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON TABLE OF CONTENTS LEGAL AND PROCEDURAL REQUIREMENTS PAGES INVITATION TO BID 1 INSTRUCTIONS TO BIDDERS 1 - 5 SUPPLEMENTAL INSTRUCTIONS TO BIDDERS 1 - 2 SUBSTITUTION REQUEST FORM I TECHNICAL SPECIFICATIONS PAGES DIVISION 01 -GENERAL REQUIREMENTS 011000 SUMMARY 1 - 6 011200 MULTIPLE CONTRACT SUMMARY 1 -4 012300 ALTERNATES 1 - 2 012600 CONTRACT MODIFICATION PROCEDURES 1 -3 012900 PAYMENT PROCEDURES 1 - 3 013100 PROJECT MANAGEMENT AND COORDINATION 1 - 7 013200 CONSTRUCTION PROGRESS DOCUMENTATION 1 - 5 013300 SUBMITTAL PROCEDURES 1 - 8 014000 QUALITY REQUIREMENTS 1 - 6 014200 REFERENCES 1 - 2 015000 TEMPORARY FACILITIES AND CONTROLS 1 - 6 015719 ENVIRONMENTAL PROTECTION AND EMERGENCY PLAN 1 -27 016000 PRODUCT REQUIREMENTS 1 -6 017300 EXECUTION 1 -5 017329 CUTTING AND PATCHING 1 -4 017419 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 1 - 6 017700 CLOSEOUT PROCEDURES 1 - 5 017823 OPERATION AND MAINTENANCE DATA 1 -4 017839 PROJECT RECORD DOCUMENTS 1 -3 017900 DEMONSTRATION AND TRAINING 1 - 3 018113.13 SUSTAINABLE DESIGN REQUIREMENTS -GREEN GLOBES FOR NEW CONSTRUCTION 1 -4 DIVISION 02-EXISTING CONDITIONS 024119 SELECTIVE STRUCTURE DEMOLITION 1 -5 DIVISION 03-CONCRETE - 033000 CAST-IN-PLACE CONCRETE 1 -9 033600 SPECIAL CONCRETE FLOOR FINISHES 1 - 5 DIVISION 05-METALS 055213 PIPE AND TUBE RAILINGS 1 - 5 TABLE OF CONTENTS 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON DIVISION 06-WOOD,PLASTICS,AND COMPOSITES 061000 ROUGH CARPENTRY 1 -5 062023 INTERIOR FINISH CARPENTRY 1 -5 064113 WOOD-VENEER-FACED ARCHITECTURAL CABINETS 1 - 7 064116 PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS 1 -7 066400 PLASTIC PANELING 1 -3 DIVISION 07-THERMAL AND MOISTURE PROTECTION 071326 SELF-ADHERING SHEET WATERPROOFING 1 - 3 072100 THERMAL INSULATION 1 - 5 076200 SHEET METAL FLASHING AND TRIM 1 -6 077200 ROOF ACCESSORIES 1 -4 079200 JOINT SEALANTS I - 9 DIVISION 08-OPENINGS 081113 HOLLOW METAL DOORS AND FRAMES 1 -7 081416 FLUSH WOOD DOORS 1 -5 083819 RIGID TRAFFIC DOORS 1 -2 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 1 -8 084229 AUTOMATIC ENTRANCES 1 - 12 087100 DOOR HARDWARE 1 - 12 088000 GLAZING 1 -6 DIVISION 09-FINISHES 092216 NON-STRUCTURAL METAL FRAMING 1 -6 092900 GYPSUM BOARD 1 -6 093000 TILING 1 -5 095113 ACOUSTICAL PANEL CEILINGS 1 -5 096513 RESILIENT BASE AND ACCESSORIES 1 -3 096723 RESINOUS FLOORING 1 - 5 099123 INTERIOR PAINTING 1 -7 099300 STAINING AND TRANSPARENT FINISHING 1 - 5 DIVISION 10-SPECIALTIES 101100 VISUAL DISPLAY SURFACES I -4 101400 SIGNAGE 1 - 3 102113 TOILET COMPARTMENTS I - 4 102600 WALL AND DOOR PROTECTION 1 - 3 102800 TOILET,BATH,AND LAUNDRY ACCESSORIES 1 - 5 104413 FIRE EXTINGUISHER CABINETS 1 - 3 104416 FIRE EXTINGUISHERS 1 -3 DIVISION 12-FURNISHINGS 122413 -ROLLER WINDOW SHADES 1 -4 123661 -SIMULATED STONE COUNTERTOPS 1 -3 DIVISION 21 -FIRE SUPPRESSION 211100 FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING 1 -7 211313 WET-PIPE SPRINKLER SYSTEMS 1 - 18 211316 DRY-PIPE SPRINKLER SYSTEMS 1 - 16 TABLE OF CONTENTS 2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON DIVISION 22-PLUMBING 21116 DOMESTIC WATER PIPING 1 -6 21119 DOMESTIC WATER PIPING SPECIALTIES 1 -9 21123 DOMESTIC WATER PUMPS 1 -4 21316 SANITARY WASTE AND VENT PIPING 1 -8 21319 SANITARY WASTE PIPING SPECIALTIES 1 -7 23400 FUEL-FIRED DOMESTIC WATER HEATERS 1 -6 24000 PLUMBING FIXTURES 1 - 5 DIVISION 23-HEATING VENTILATING AND AIR CONDITIONING 230500 COMMON WORK RESULTS FOR PLUMBING AND HVAC 1 - 11 230513 COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT 1 -6 230519 METERS AND GAGES FOR PLUMBING PIPING 1 -4 230523 GENERAL-DUTY VALVES FOR PLUMBING PIPING 1 -6 230529 HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT 1 -8 230548 VIBRATION AND SEISMIC CONTROLS FOR PLUMBING AND HVAC PIPING AND EQUIPMENT 1 -9 230553 IDENTIFICATION FOR PLUMBING AND HVAC PIPING AND EQUIPMENT 1 -4 230593 TESTING,ADJUSTING,AND BALANCING FOR HVAC 1 -5 230700 HVAC INSULATION 1 - 11 230993 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1 - 5 231123 FACILITY NATURAL-GAS PIPING 1 -9 233113 METAL DUCTS 1 - 14 233300 AIR DUCT ACCESSORIES 1 -9 233423 HVAC POWER VENTILATORS 1 -7 233713 DIFFUSERS,REGISTERS,AND GRILLES 1 -3 233813 COMMERCIAL-KITCHEN HOODS 1 - 8 235100 BREECHINGS,CHIMNEYS,AND STACKS 1 -3 235523 GAS-FIRED RADIANT HEATERS 1 -4 235533 FUEL-FIRED UNIT HEATERS 1 -4 236395 REFRIGERATION INSTALLATION 1 -48 237400 PACKAGED OUTDOOR HVAC EQUIPMENT 1 -6 237433 DEDICATED OUTDOOR-AIR UNITS 1 - 10 238126 SPLIT-SYSTEM AIR-CONDITIONERS 1 -4 238315 QUARTZ ELECTRIC INFRARED HEATERS 1 -2 DIVISION 26-ELECTRICAL 260500 COMMON WORK RESULTS FOR ELECTRICAL 1 -3 260519 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 1 -5 260526 GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 1 -3 260529 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 1 -5 260533 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS 1 -7 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS 1 -7 260573 OVERCURRENT PROTECTIVE DEVICE COORDINATION AND ARC FLASH STUDY 1 - 8 260943 NETWORK LIGHTING CONTROLS 1 - 5 262200 LOW-VOLTAGE TRANSFORMERS 1 -4 262413 SWITCHBOARDS 1 -6 262416 PANELBOARDS 1 -7 262726 WIRING DEVICES 1 -6 TABLE OF CONTENTS 3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 262813 FUSES 1 -3 262816 ENCLOSED SWITCHES AND CIRCUIT BREAKERS 1 -5 262913 ENCLOSED CONTROLLERS 1 -7 265100 INTERIOR LIGHTING 1 -7 DIVISION 28-ELECTRICAL SAFETY AND SECURITY 283111 DIGITAL,ADDRESSABLE FIRE-ALARM SYSTEM 1 -8 TABLE OF CONTENTS 4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON SECTION 221116-DOMESTIC WATER PIPING PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,apply to this Section. 1.2 SUMMARY A. This Section includes domestic water piping inside the building. B. Water meters will be furnished and installed by utility company. 1.3 SUBMITTALS A. Product Data: For pipe,tube,fittings,and couplings. B. Field quality-control test reports. 1.4 QUALITY ASSURANCE A. Piping materials shall bear label,stamp,or other markings of specified testing agency. B. Comply with NSF 61, "Drinking Water System Components - Health Effects; Sections 1 through 9,"for potable domestic water piping and components. PART 2-PRODUCTS 2.1 PIPING MATERIALS A. Refer to Part 3 "Pipe and Fitting Applications"Article for applications of pipe,tube,fitting,and joining materials. B. Transition Couplings for Aboveground Pressure Piping: Coupling or other manufactured fitting the same size as, with pressure rating at least equal to and ends compatible with, piping to be joined. 2.2 COPPER TUBE AND FITTINGS A. Soft Copper Tube: ASTM B 88,Types K,water tube,annealed temper. DOMESTIC WATER PIPING 221116- 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 1. Copper Pressure Fittings: ASME B16.18, cast-copper-alloy or ASME B16.22,wrought- copper,solder joint fittings. Furnish wrought-copper fittings if indicated. 2. Bronze Flanges: ASME 816.24, Class 150, with solder joint ends. Furnish Class 300 flanges if required to match piping. 3. Copper Unions: MSS SP-1 23, cast-copper-alloy, hexagonal-stock body, with ball-and- socket,metal-to-metal seating surfaces,and solder joint or threaded ends. B. Hard Copper Tube: ASTM B 88,Types L,water tube,drawn temper. 1. Copper Pressure Fittings: ASME B16.18,cast-copper-alloy or ASME B16.22,wrought- copper,solder joint fittings. Furnish wrought-copper fittings if indicated. 2. Bronze Flanges: ASME B16.24, Class 150, with solder joint ends. Furnish Class 300 flanges if required to match piping. 3. Copper Unions: MSS SP-123, cast-copper-alloy, hexagonal-stock body, with ball-and- socket,metal-to-metal seating surfaces,and solder joint or threaded ends. PART 3-EXECUTION 3.1 EXCAVATION A. Excavating,trenching,and backfilling are specified in Division 02 Section"Earthwork." 3.2 PIPE AND FITTING APPLICATIONS A. Transition and special fittings with pressure ratings at least equal to piping rating may be used in applications below,unless otherwise indicated. B. Flanges may be used on aboveground piping,unless otherwise indicated. C. Under-Building-Slab, Water-Service Piping on Service Side of Water Meter: Refer to Division 02 Section"Water Distribution." D. Under-Building-Slab, Domestic Water Piping on House Side of Water Meter, NPS 6 and Smaller: Soft copper tube,Type K;copper pressure fittings;and brazed joints. E. Aboveground Domestic Water Piping: Use the following piping materials: 1. NPS 6 and Smaller: Hard copper tube, Type L; copper pressure fittings; and soldered joints. 3.3 VALVE APPLICATIONS A. Drawings indicate valve types to be used. Where specific valve types are not indicated, the following requirements apply: 1. Shutoff Duty: Use bronze ball valves for piping NPS 2 and smaller. Use cast-iron butterfly valves with flanged ends for piping NPS 2-1/2 and larger. DOMESTIC WATER PIPING 221116-2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 2. Throttling Duty: Use bronze ball or globe valves for piping NPS 2 and smaller. Use cast-iron butterfly valves with flanged ends for piping NPS 2-1/2 and larger. 3. Hot-Water-Piping,Balancing Duty: Calibrated balancing valves. 4. Drain Duty: Hose-end drain valves. B. Install shutoff valve close to water main on each branch and riser serving plumbing fixtures or equipment, on each water supply to equipment, and on each water supply to plumbing fixtures that do not have supply stops. Use ball valves for piping NPS 2 and smaller. Use butterfly valves for piping NPS 2-1/2 and larger. C. Install drain valves for equipment at base of each water riser,at low points in horizontal piping, and where required to drain water piping. 1. Install hose-end drain valves at low points in water mains,risers,and branches. 2. Install stop-and-waste drain valves where indicated. D. Install calibrated balancing valves in each hot-water circulation return branch and discharge side of each pump and circulator. Set calibrated balancing valves partly open to restrict but not stop flow. 3.4 PIPING INSTALLATION A. Install under-building-slab copper tubing according to CDA's"Copper Tube Handbook." B. Install sleeve with water stop and mechanical sleeve seal at each service pipe penetration through foundation wall. Select number of interlocking rubber links required to make installation watertight. C. Install shutoff valve, hose-end drain valve, strainer, pressure gage, and test tee with valve, inside the building at each domestic water service entrance. D. Install domestic water piping level and plumb. E. Rough-in domestic water piping for water-meter installation according to utility company's requirements. 3.5 JOINT CONSTRUCTION A. Soldered Joints: Use ASTM B 813, water-flushable, lead-free flux; ASTM B 32, lead-free- alloy solder;and ASTM B 828 procedure,unless otherwise indicated. 3.6 WATER METER INSTALLATION A. Rough-in domestic water piping for water meter installation according to utility company's requirements. B. Water meters will be furnished and installed by utility company. DOMESTIC WATER PIPING 221116-3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 3.7 HANGER AND SUPPORT INSTALLATION A. Install hangers for copper tubing with the following maximum horizontal spacing and minimum rod diameters: 1. NPS 3/4 and Smaller. 60 inches with 3/8-inch rod. 2. NPS 1 and NPS 1-1/4: 72 inches with 3/8-inch rod. 3. NPS 1-1/2 and NPS 2: 96 inches with 3/8-inch rod. 4. NPS 2-1/2: 108 inches with 1/2-inch rod. 5. NPS 3 to NPS 5: 10 feet with 1/2-inch rod. B. Install supports for vertical copper tubing every 10 feet. C. Support piping and tubing not listed above according to MSS SP-69 and manufacturer's written instructions. 3.8 CONNECTIONS A. Drawings indicate general arrangement of piping,fittings,and specialties. B. Install piping adjacent to equipment and machines to allow service and maintenance. C. Connect domestic water piping to exterior water-service piping. Use transition fitting to join dissimilar piping materials. D. Connect domestic water piping to water-service piping with shutoff valve, and extend and connect to the following: 1. Water Heaters: Cold-water supply and hot-water outlet piping in sizes indicated,but not smaller than sizes of water heater connections. 2. Plumbing Fixtures: Cold-and hot-water supply piping in sizes indicated,but not smaller than required by plumbing code. 3. Equipment: Cold- and hot-water supply piping as indicated, but not smaller than equipment connections. Provide shutoff valve and union for each connection. Use flanges instead of unions for NPS 2-1/2 and larger. 3.9 FIELD QUALITY CONTROL A. Inspect domestic water piping as follows: 1. Do not enclose, cover, or put piping into operation until it has been inspected and approved by authorities having jurisdiction. 2. During installation, notify authorities having jurisdiction at least 24 hours before inspection must be made. Perform tests specified below in presence of authorities having jurisdiction: a. Roughing-in Inspection: Arrange for inspection of piping before concealing or closing-in after roughing-in and before setting fixtures. DOMESTIC WATER PIPING 221116-4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON b. Final Inspection: Arrange final inspection for authorities having jurisdiction to observe tests specified below and to ensure compliance with requirements. 3. Reinspection: If authorities having jurisdiction find that piping will not pass test or inspection,make required corrections and arrange for reinspection. 4. Reports: Prepare inspection reports and have them signed by authorities having jurisdiction. B. Test domestic water piping as follows: 1. Fill domestic water piping. Check components to determine that they are not air bound and that piping is full of water. 2. Test for leaks and defects in new piping and parts of existing piping that have been altered,extended,or repaired. If testing is performed in segments, submit separate report for each test,complete with diagram of portion of piping tested. 3. Leave new, altered, extended, or replaced domestic water piping uncovered and unconcealed until it has been tested and approved. Expose work that was covered or concealed before it was tested. 4. Cap and subject piping to static water pressure of 50 psig above operating pressure, without exceeding pressure rating of piping system materials. Isolate test source and allow to stand for four hours. Leaks and loss in test pressure constitute defects that must be repaired. 5. Repair leaks and defects with new materials and retest piping or portion thereof until satisfactory results are obtained. 6. Prepare reports for tests and required corrective action. 3.10 ADJUSTING A. Perform the following adjustments before operation: 1. Close drain valves,hydrants,and hose bibbs. 2. Open shutoff valves to fully open position. 3. Open throttling valves to proper setting. 4. Adjust balancing valves in hot-water-circulation return piping to provide adequate flow. a. Adjust calibrated balancing valves to flows indicated. 5. Remove plugs used during testing of piping and plugs used for temporary sealing of piping during installation. 6. Remove and clean strainer screens. Close drain valves and replace drain plugs. 7. Remove firer cartridges from housings and verify that cartridges are as specified for application where used and are clean and ready for use. 8. Check plumbing specialties and verify proper settings,adjustments,and operation. 3.11 CLEANING A. Clean and disinfect potable domestic water piping as follows: DOMESTIC WATER PIPING 221116-5 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 1. Purge new piping and parts of existing domestic water piping that have been altered, extended,or repaired before using. 2. Use purging and disinfecting procedures prescribed by authorities having jurisdiction or, if methods are not prescribed, procedures described in either AWWA C651 or AWWA C652 or as described below: a. Flush piping system with clean, potable water until dirty water does not appear at outlets. b. Fill and isolate system according to either of the following: 1) Fill system or part thereof with water/chlorine solution with at least 50 ppm of chlorine. Isolate with valves and allow to stand for 24 hours. 2) Fill system or part thereof with water/chlorine solution with at least 200 ppm of chlorine. Isolate and allow to stand for three hours. c. Flush system with clean, potable water until no chlorine is in water coming from system after the standing time. d. Submit water samples in sterile bottles to authorities having jurisdiction. Repeat procedures if biological examination shows contamination. B. Prepare and submit reports of purging and disinfecting activities. C. Clean interior of domestic water piping system. Remove dirt and debris as work progresses. END OF SECTION 221116 DOMESTIC WATER PIPING 221116-6 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON SECTION 221119-DOMESTIC WATER PIPING SPECIALTIES PART I -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,apply to this Section. 1.2 SUMMARY A. This Section includes the following domestic water piping specialties: 1. Vacuum breakers. 2. Backflow preventers. 3. Water pressure-reducing valves. 4. Balancing valves. 5. Temperature-actuated water mixing valves. 6. Strainers. 7. Hose stations. 8. Hose bibbs. 9. Wall hydrants. 10. Water hammer arresters. 11. Trap-seal primer valves. 1.3 PERFORMANCE REQUIREMENTS A. Minimum Working Pressure for Domestic Water Piping Specialties: 125 psig,unless otherwise indicated. 1.4 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Diagram power,signal,and control wiring. C. Operation and Maintenance Data: For domestic water piping specialties to include in emergency,operation,and maintenance manuals. 1.5 QUALITY ASSURANCE A. NSF Compliance: DOMESTIC WATER PIPING SPECIALTIES 221119- 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 1. Comply with NSF 61, "Drinking Water System Components-Health Effects; Sections 1 through 9." PART 2-PRODUCTS 2.1 VACUUM BREAKERS A. Pipe-Applied,Atmospheric-Type Vacuum Breakers: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Ames Co. b. Cash Acme. c. Conbraco Industries,Inc. d. FEBCO; SPX Valves&Controls. e. Rain Bird Corporation. f. Toro Company(The);Irrigation Div. g. Watts Industries,Inc.;Water Products Div. h. Zurn Plumbing Products Group;Wilkins Div. 2. Standard: ASSE 1001. 3. Size: NPS 1/4 to NPS 3,as required to match connected piping. 4. Body: Bronze. 5. Inlet and Outlet Connections: Threaded. 6. Finish: Chrome plated. B. Pressure Vacuum Breakers: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Ames Co. b. Conbraco Industries,Inc. c. FEBCO; SPX Valves&Controls. d. Flomatic Corporation. e. Toro Company(The);Irrigation Div. f. Watts Industries,Inc.;Water Products Div. g. Zurn Plumbing Products Group;Wilkins Div. 2. Standard: ASSE 1020. 3. Operation: Continuous-pressure applications. 4. Pressure Loss: 5 psig maximum,through middle 1/3 of flow range. 5. Accessories: a. Valves: Ball type,on inlet and outlet. DOMESTIC WATER PIPING SPECIALTIES 221119-2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 2.2 BACKFLOW PREVENTERS A. Reduced-Pressure-Principle Backflow Preventers: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Ames Co. b. Conbraco Industries, Inc. c. FEBCO; SPX Valves&Controls. d. Flomatic Corporation. e. Watts Industries,Inc.; Water Products Div. f. Zurn Plumbing Products Group;Wilkins Div. B. Double-Check Backflow-Prevention Assemblies: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Ames Co. b. Conbraco Industries, Inc. c. FEBCO; SPX Valves&Controls. d. Flomatic Corporation. e. Watts Industries,Inc.; Water Products Div. f. Zurn Plumbing Products Group;Wilkins Div. 2. Accessories: a. Valves: Ball type with threaded ends on inlet and outlet of NPS 2 and smaller; outside screw and yoke gate-type with flanged ends on inlet and outlet of NPS 2- 1/2 and larger. C. Beverage-Dispensing-Equipment Backflow Preventers: I. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Conbraco Industries, Inc. b. Watts Industries, Inc.; Water Products Div. c. Zurn Plumbing Products Group; Wilkins Div. 2.3 BALANCING VALVES A. Automatic Flow-Control Balancing Valves: Factory set to maintain constant flow with plus or minus 5 percent over system pressure fluctuations. Each valve shall have an identification tag attached by chain, and be factory marked with the zone identification, valve number, and flow rate. Valve shall be line size with the following design: DOMESTIC WATER PIPING SPECIALTIES 221119-3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 1. Brass or ferrous-metal body,designed for 150 psig at 250 deg F with corrosion-resistant, tamperproof, self-cleaning, piston-spring assembly easily removable for inspection or replacement. B. Accessories: Meter hoses,fittings,valves,differential pressure meter,and carrying case. 2.4 TEMPERATURE-ACTUATED WATER MIXING VALVES A. Water-Temperature Limiting Devices: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Armstrong International,Inc. b. Bradley Corporation. c. Cash Acme. d. Conbraco Industries,Inc. e. Honeywell Water Controls. f. Legend Valve. g. Leonard Valve Company. h. Powers;a Watts Industries Co. i. Symmons Industries,Inc. j. Taco,Inc. k. Watts Industries,Inc.;Water Products Div. 1. Zurn Plumbing Products Group;Wilkins Div. B. Primary,Thermostatic,Water Mixing Valves: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Armstrong International,Inc. b. Bradley Corporation. c. Lawler Manufacturing Company, Inc. d. Leonard Valve Company. e. Powers;a Watts Industries Co. f. Symmons Industries,Inc. C. Individual-Fixture,Water Tempering Valves: 1. Available Manufacturers: Subject to compliance with requirements, provide product by the following: a. Honeywell Water Controls. D. Primary Water Tempering Valves: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: DOMESTIC WATER PIPING SPECIALTIES 221119-4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON a. Heat-Timer Corporation. b. Holby Valve Co.,Inc. 2.5 STRAINERS FOR DOMESTIC WATER PIPING A. Y-Pattern Strainers: 1. Pressure Rating: 125 psig minimum,unless otherwise indicated. 2. Body: Bronze for NPS 2 and smaller;cast iron for NPS 2-1/2 and larger. 3. End Connections: Threaded for NPS 2 and smaller;flanged for NPS 2-1/2 and larger. 4. Screen: Stainless steel with round perforations,unless otherwise indicated. 5. Drain: Factory-installed,hose-end drain valve. 2.6 HOSE BIBBS A. Hose Bibbs: 1. Standard: ASME A112.18.1 for sediment faucets. 2. Body Material: Bronze. 3. Seat: Bronze,replaceable. 4. Supply Connections: NPS 1/2 or NPS 3/4 threaded or solder joint inlet. 5. Outlet Connection: Garden-hose thread complying with ASME B 1.20.7. 6. Pressure Rating: 125 psig. 7. Vacuum Breaker: Integral nonremovable, drainable, hose-connection vacuum breaker complying with ASSE 1011. 8. Finish for Equipment Rooms: Rough bronze,or chrome or nickel plated. 9. Finish for Service Areas: Chrome or nickel plated. 10. Finish for Finished Rooms: Chrome or nickel plated. 11. Operation for Equipment Rooms: Wheel handle or operating key. 12. Operation for Service Areas: Wheel handle. 13. Operation for Finished Rooms: Wheel handle. 14. Include wall flange with each chrome-or nickel-plated hose bibb. 2.7 WALL HYDRANTS A. Nonfreeze Wall Hydrants: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Josam Company. b. MIFAB,Inc. c. Prier Products,Inc. d. Smith,Jay R. Mfg.Co.;Division of Smith Industries,Inc. e. Tyler Pipe;Wade Div. f. Watts Drainage Products Inc. g. Woodford Manufacturing Company. DOMESTIC WATER PIPING SPECIALTIES 221119-5 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON h. Zurn Plumbing Products Group;Light Commercial Operation. i. Zurn Plumbing Products Group; Specification Drainage Operation. 2. Inlet: NPS 3/4 or NPS 1. 3. Outlet: Concealed,with integral vacuum breaker and garden-hose thread complying with ASME B1.20.7. 4. Box: Deep,flush mounting with cover. 5. Box and Cover Finish: Polished nickel bronze or chrome plated. 6. Outlet: Exposed, with integral vacuum breaker and garden-hose thread complying with ASME B1.20.7. 7. Nozzle and Wall-Plate Finish: Polished nickel bronze. 8. Operating Keys: Two with each wall hydrant. B. Nonfreeze,Hot-and Cold-Water Wall Hydrants: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Josam Company. b. Prier Products,Inc. c. Smith,Jay R.Mfg.Co.;Division of Smith Industries,Inc. d. Tyler Pipe;Wade Div. e. Watts Drainage Products Inc. f. Woodford Manufacturing Company. g. Zurn Plumbing Products Group; Specification Drainage Operation. C. Vacuum Breaker Wall Hydrants: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. Arrowhead Brass Products,Inc. b. Mansfield Plumbing Products LLC. c. McDonald,A.Y.Mfg.Co. d. Prier Products,Inc. e. Smith,Jay.R.Mfg.Co.;Division of Smith Industries,Inc. f. Watts Industries,Inc.;Water Products Div. g. Woodford Manufacturing Company. h. Zurn Plumbing Products Group;Light Commercial Operation. 2.8 WATER HAMMER ARRESTERS A. Water Hammer Arresters: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. AMTROL,Inc. b. Josam Company. DOMESTIC WATER PIPING SPECIALTIES 221119-6 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON c. MIFAB, Inc. d. PPP Inc. e. Sioux Chief Manufacturing Company, Inc. f. Smith,Jay R. Mfg. Co.; Division of Smith Industries,Inc. g. Tyler Pipe;Wade Div. h. Watts Drainage Products Inc. i. Zurn Plumbing Products Group; Specification Drainage Operation. 2.9 TRAP-SEAL PRIMER VALVES A. Supply-Type,Trap-Seal Primer Valves: 1. Available Manufacturers: Subject to compliance with requirements,provide products by one of the following: a. MIFAB,Inc. b. PPP Inc. c. Sioux Chief Manufacturing Company, Inc. d. Smith,Jay R. Mfg. Co.; Division of Smith Industries,Inc. e. Watts Industries, Inc.; Water Products Div. 2. Standard: ASSE 1018. 3. Pressure Rating: 125 psig minimum. 4. Body: Bronze. 5. Inlet and Outlet Connections: NPS 1/2 threaded,union,or solder joint. 6. Gravity Drain Outlet Connection: NPS 1/2 threaded or solder joint. 7. Finish: Chrome plated, or rough bronze for units used with pipe or tube that is not chrome finished. PART 3 -EXECUTION 3.1 INSTALLATION A. Refer to Section 230500 "Common Work Results for HVAC" for piping joining materials,joint construction,and basic installation requirements. B. Install backflow preventers in each water supply to mechanical equipment and systems and to other equipment and water systems that may be sources of contamination. Comply with authorities having jurisdiction. 1. Locate backflow preventers in same room as connected equipment or system. 2. Install drain for backflow preventers with atmospheric-vent drain connection with air-gap fitting, fixed air-gap fitting, or equivalent positive pipe separation of at least two pipe diameters in drain piping and pipe to floor drain. Locate air-gap device attached to or under backflow preventer. Simple air breaks are not acceptable for this application. 3. Do not install bypass piping around backflow preventers. DOMESTIC WATER PIPING SPECIALTIES 221119-7 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON C. Install balancing valves in locations where they can easily be adjusted. D. Install temperature-actuated water mixing valves with check stops or shutoff valves on inlets and with shutoff valve on outlet. 1. Install thermometers and water regulators if specified. 2. Install cabinet-type units recessed in or surface mounted on wall as specified. E. Install Y-pattern strainers for water on supply side of each control valve and pump. F. Install hose stations with check stops or shutoff valves on inlets and with thermometer on outlet. 1. Install shutoff valve on outlet if specified. 2. Install cabinet-type units recessed in or surface mounted on wall as specified. Install 2- by-4-inch fire-retardant-treated-wood blocking wall reinforcement between studs. Fire- retardant-treated-wood blocking is specified in Division 06 Section"Rough Carpentry." G. Install water hammer arresters in water piping according to PDI-WH 201. H. Install air vents at high points of water piping. - I. Install supply-type, trap-seal primer valves with outlet piping pitched down toward drain trap a minimum of 1 percent, and connect to floor-drain body, trap, or inlet fitting. Adjust valve for proper flow. J. Install trap-seal primer systems with outlet piping pitched down toward drain trap a minimum of 1 percent,and connect to floor-drain body,trap,or inlet fitting. Adjust system for proper flow. 3.2 CONNECTIONS A. Piping installation requirements are specified in other Mechanical Sections. Drawings indicate general arrangement of piping and specialties. B. Ground equipment according to Section 260526 "Grounding and Bonding for Electrical Systems." C. Connect wiring according to Section 280513 "Conductors and Cables for Electronic Safety." 3.3 FIELD QUALITY CONTROL A. Perform the following tests and prepare test reports: 1. Test each pressure vacuum breaker, reduced-pressure-principle backflow preventer, and double-check backflow-prevention assembly according to authorities having jurisdiction and the device's reference standard. B. Remove and replace malfunctioning domestic water piping specialties and retest as specified above. DOMESTIC WATER PIPING SPECIALTIES 221119-8 �ANTFOODs T IGO' GOE��„-GREW 3.q ON S AY?'OWN ADJUSTING ENTER A. Set field-adjustable 8S,I,E B Set field-adjustable flow set points of EMIT DOCUMENTS OF temperature balancing valves SECTION 221119 set paints aftemperature-actuated water.mixinEND g valves. DOMESTIC WATER PIPING SPECIALTIES 221119--9 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON SECTION 221123 - DOMESTIC WATER PUMPS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,apply to this Section. 1.2 SUMMARY A. This Section includes the following all-bronze and bronze-fitted centrifugal pumps for domestic cold-and hot-water circulation: 1. High velocity cartridge circulator. 1.3 SUBMITTALS A. Product Data: For each type and size of domestic water pump specified. Include certified performance curves with operating points plotted on curves; and rated capacities of selected models, furnished specialties,and accessories. B. Shop Drawings: Diagram power,signal,and control wiring. C. Operation and Maintenance Data: For domestic water pumps to include in emergency, operation,and maintenance manuals. 1.4 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. B. UL Compliance: Comply with UL 778 for motor-operated water pumps. PART 2-PRODUCTS 2.1 MANUFACTURERS A. In other Part 2 articles where titles below introduce lists, the following requirements apply to product selection: DOMESTIC WATER PUMPS 221123 - 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, manufacturers specified. 2.2 HIGH VELOCITY CARTRIDGE CIRCULATOR A. Available Manufacturers: 1. Armstrong Pumps Inc. 2. Bell&Gossett Domestic Pump;ITT Industries. 3. Grundfos Pumps Corp. 4. Taco,Inc. B. Description: Factory-assembled and -tested, single-stage, close-coupled, in-line, sealless centrifugal pumps. 1. Pump and Motor Assembly: Hermetically sealed, replaceable-cartridge-type unit with motor and impeller on common shaft and designed for installation with pump and motor shaft mounted horizontally. 2. Casing: Bronze,with threaded companion-flange connections. 3. Impeller: Corrosion-resistant material. 4. Motor: Single speed,unless otherwise indicated. 2.3 CONTROLS A. Thermostats: Electric;adjustable for control of hot-water circulation pump. 1. Available Manufacturers: a. Honeywell International,Inc. b. Square D. c. White-Rodgers Div.;Emerson Electric Co. 2. Type: Water-immersion sensor,for installation in hot-water circulation piping. 3. Range: 100 to 240 deg F. 4. Operation of Pump: On or off. 5. Transformer: Provide if required. 6. Power Requirement: 120 V,ac. 7. Settings: Start pump at 125 deg F and stop pump at 140 deg F. B. Strap-on aquastat. C. Timer. DOMESTIC WATER PUMPS 221123-2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85% PERMIT DOCUMENTS TIGARD,OREGON PART 3 -EXECUTION 3.1 EXAMINATION A. Examine roughing-in of domestic-water-piping system to verify actual locations of connections before pump installation. 3.2 PUMP INSTALLATION A. Comply with HI 1.4. B. Install pumps with access for periodic maintenance including removal of motors, impellers, couplings,and accessories. C. Independently support pumps and piping so weight of piping is not supported by pumps and weight of pumps is not supported by piping. D. Install in-line,sealless centrifugal pumps with motor and pump shafts horizontal. 3.3 CONTROL INSTALLATION A. Install immersion-type thermostats in hot-water return piping. 3.4 CONNECTIONS A. Drawings indicate general arrangement of piping,fittings,and specialties. B. Install piping adjacent to pumps to allow service and maintenance. C. Connect domestic water piping to pumps. Install suction and discharge piping equal to or greater than size of pump nozzles. 1. Install shutoff valve and strainer on suction side of pumps,and check valve and throttling valve on discharge side of pumps. Install valves same size as connected piping. 2. Install pressure gages at suction and discharge of pumps. Install at integral pressure-gage tappings where provided or install pressure-gage connectors in suction and discharge piping around pumps. D. Ground equipment according to Section 260526"Grounding and Bonding for Electrical Systems." E. Connect wiring according to Section 280513 "Conductors and Cables for Electronic Safety." F. Connect thermostats to pumps that they control. DOMESTIC WATER PUMPS 221123 -3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 3.5 STARTUP SERVICE A. Engage a service representative to perform startup service. 1. Complete installation and startup checks according to manufacturer's written instructions. 2. Check piping connections for tightness. 3. Clean strainers on suction piping. 4. Set thermostats for automatic starting and stopping operation of pumps. 5. Perform the following startup checks for each pump before starting: a. Verify bearing lubrication. b. Verify that pump is free to rotate by hand and that pump for handling hot liquid is free to rotate with pump hot and cold. If pump is bound or drags, do not operate until cause of trouble is determined and corrected. c. Verify that pump is rotating in the correct direction. 6. Prime pump by opening suction valves and closing drains, and prepare pump for operation. 7. Start motor. 8. Open discharge valve slowly. - 9. Adjust temperature settings on thermostats. 10. Adjust timer settings. 3.6 DEMONSTRATION A. Engage a service representative to train Owner's maintenance personnel to adjust, operate, and maintain controls and pumps. END OF SECTION 221123 DOMESTIC WATER PUMPS 221123 -4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON SECTION 221316-SANITARY WASTE AND VENT PIPING PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,apply to this Section. 1.2 SUMMARY A. This Section includes the following for soil,waste,and vent piping inside the building: 1. Pipe,tube,and fittings. 2. Special pipe fittings. 1.3 DEFINITIONS A. EPDM: Ethylene-propylene-diene terpolymer rubber. B. LLDPE: Linear,low-density polyethylene plastic. C. NBR: Acrylonitrile-butadiene rubber. D. PE: Polyethylene plastic. E. PVC: Polyvinyl chloride plastic. 1.4 PERFORMANCE REQUIREMENTS A. Components and installation shall be capable of withstanding the following minimum working pressure,unless otherwise indicated: 1. Soil,Waste,and Vent Piping: 10 foot head of water. B. Seismic Performance: Soil,waste,and vent piping and support and installation shall be capable of withstanding the effects of seismic events determined according to ASCE 7, "Minimum Design Loads for Buildings and Other Structures." 1.5 SUBMITTALS A. Product Data: For pipe,tube,fittings,and couplings. SANITARY WASTE AND VENT PIPING 221316- 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85% PERMIT DOCUMENTS TIGARD,OREGON 1.6 QUALITY ASSURANCE A. Piping materials shall bear label,stamp,or other markings of specified testing agency. B. Comply with NSF 14, "Plastics Piping Systems Components and Related Materials," for plastic piping components. Include marking with"NSF-dwv" for plastic drain,waste,and vent piping; "NSF-drain" for plastic drain piping; "NSF-tubular" for plastic continuous waste piping; and "NSF-sewer" for plastic sewer piping. PART 2-PRODUCTS 2.1 PIPING MATERIALS A. Refer to Part 3 "Piping Applications" Article for applications of pipe, tube, fitting, and joining materials. 2.2 HUBLESS CAST-IRON SOIL PIPE AND FITTINGS A. Pipe and Fittings: ASTM A 888 or CISPI 301. B. Shielded Couplings: ASTM C 1277 assembly of metal shield or housing, corrosion-resistant fasteners,and rubber sleeve with integral,center pipe stop. 1. Standard, Shielded, Stainless-Steel Couplings: CISPI 310,with stainless-steel corrugated shield;stainless-steel bands and tightening devices;and ASTM C 564,rubber sleeve. a. Available Manufacturers: 1) ANACO. 2) Fernco,Inc. 3) Ideal Div.; Stant Corp. 4) Mission Rubber Co. 5) Tyler Pipe; Soil Pipe Div. 2. Heavy-Duty, Shielded, Stainless-Steel Couplings: With stainless-steel shield, stainless- steel bands and tightening devices,and ASTM C 564,rubber sleeve. a. Available Manufacturers: 1) ANACO. 2) Clamp-All Corp. 3) Ideal Div.; Stant Corp. 4) Mission Rubber Co. 5) Tyler Pipe; Soil Pipe Div. 3. Heavy-Duty, Shielded, Cast-Iron Couplings: ASTM A 48/A 48M, two-piece, cast-iron housing;stainless-steel bolts and nuts;and ASTM C 564,rubber sleeve. SANITARY WASTE AND VENT PIPING 221316-2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON a. Available Manufacturers: 1) MG Piping Products Co. 2.3 PVC PIPE AND FITTINGS A. Solid-Wall PVC Pipe: ASTM D 2665,drain,waste,and vent. 1. PVC Socket Fittings: ASTM D 2665,socket type,made to ASTM D 3311,drain,waste, and vent patterns. 2.4 SPECIAL PIPE FITTINGS A. Pressure Pipe Couplings: AWWA C219 metal,sleeve-type same size as,with pressure rating at least equal to,and ends compatible with,pipes to be joined. 1. Available Manufacturers: a. Cascade Waterworks Mfg.Co. b. Dresser, Inc.;DMD Div. c. EBAA Iron Sales,Inc. d. Ford Meter Box Company,Inc.(The);Pipe Products Div. e. JCM Industries,Inc. f. Romac Industries,Inc. g. Smith-Blair,Inc. h. Viking Johnson. 2. Center-Sleeve Material: Manufacturer's standard. 3. Gasket Material: Natural or synthetic rubber. 4. Metal Component Finish: Corrosion-resistant coating or material. B. Expansion Joints: Two or three-piece,ductile-iron assembly consisting of telescoping sleeve(s) with gaskets and restrained-type, ductile-iron, bell-and-spigot end sections complying with AWWA C110 or AWWA C153. Select and assemble components for expansion indicated. Include AWWA C111,ductile-iron glands,rubber gaskets,and steel bolts. 1. Available Manufacturers: a. EBAA Iron Sales,Inc. b. Romac Industries,Inc. — c. Star Pipe Products; Star Fittings Div. C. Wall-Penetration Fittings: Compound, ductile-iron coupling fitting with sleeve and flexing sections for up to 20-degree deflection, gaskets, and restrained joint ends complying with AWWA C110 or AWWA C153. Include AWWA C111, ductile-iron glands, rubber gaskets, and steel bolts. 1. Available Manufacturers: SANITARY WASTE AND VENT PIPING 221316-3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85% PERMIT DOCUMENTS TIGARD,OREGON a. SIGMA Corp. PART 3-EXECUTION 3.1 EXCAVATION A. Refer to Division 31 Section"Earthwork"for excavating,trenching,and backfilling. 3.2 PIPING APPLICATIONS A. Flanges and unions may be used on aboveground pressure piping,unless otherwise indicated. B. Aboveground,soil and waste piping NPS 4 and smaller shall be any of the following: 1. Service class,cast-iron soil pipe and fittings;gaskets;and compression joints. 2. Hubless cast-iron soil pipe and fittings; heavy-duty shielded couplings; and hubless- coupling joints. 3. Solid-wall PVC pipe,PVC socket fittings,and solvent-cemented joints. C. Aboveground,vent piping NPS 4 and smaller shall be any of the following: 1. Service class,cast-iron soil pipe and fittings;gaskets;and compression joints. 2. Hubless cast-iron soil pipe and fittings; heavy-duty shielded couplings; and hubless- coupling joints. 3. Solid-wall PVC pipe,PVC socket fittings,and solvent-cemented joints. D. Underground,soil,waste,and vent piping NPS 4 and smaller shall be any of the following: 1. Service class,cast-iron soil piping;gaskets;and gasketed joints. 2. Hubless cast-iron soil pipe and fittings; heavy-duty shielded couplings; and hubless- coupling joints. 3. Solid wall PVC pipe,PVC socket fittings,and solvent-cemented joints. E. Underground,soil and waste piping NPS 5 and larger shall be any of the following: 1. Service class,cast-iron soil piping;gaskets; and compression joints. 2. Hubless cast-iron soil pipe and fittings; heavy-duty shielded couplings; and hubless- coupling joints. 3. Solid-wall,Schedule 40,PVC pipe;PVC socket fittings;and solvent-cemented joints. 3.3 PIPING INSTALLATION A. Sanitary sewer piping outside the building is specified in Division 22 Section"Facility Sanitary Sewerage." B. Basic piping installation requirements are specified in Division 22 Sections. SANITARY WASTE AND VENT PIPING 221316-4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON C. Install seismic restraints on piping. Seismic-restraint devices are specified in Division 22 Section"Mechanical Vibration and Seismic Controls." D. Install cleanouts at grade and extend to where building sanitary drains connect to building sanitary sewers. E. Install wall-penetration fitting at each service pipe penetration through foundation wall. Make installation watertight. F. Install cast-iron soil piping according to CISPI's "Cast Iron Soil Pipe and Fittings Handbook," Chapter IV,"Installation of Cast Iron Soil Pipe and Fittings." 1. Install encasement on underground piping according to ASTM A 674 or AWWA C105. G. Make changes in direction for soil and waste drainage and vent piping using appropriate branches,bends, and long-sweep bends. Sanitary tees and short-sweep 1/4 bends may be used on vertical stacks if change in direction of flow is from horizontal to vertical. Use long-turn, double Y-branch and 1/8-bend fittings if 2 fixtures are installed back to back or side by side with common drain pipe. Straight tees,elbows,and crosses may be used on vent lines. Do not change direction of flow more than 90 degrees. Use proper size of standard increasers and reducers if pipes of different sizes are connected. Reducing size of drainage piping in direction of flow is prohibited. H. Lay buried building drainage piping beginning at low point of each system. Install true to grades and alignment indicated, with unbroken continuity of invert. Place hub ends of piping upstream. Install required gaskets according to manufacturer's written instructions for use of lubricants, cements, and other installation requirements. Maintain swab in piping and pull past each joint as completed. I. Install soil and waste drainage and vent piping at the following minimum slopes, unless otherwise indicated: 1. Building Sanitary Drain: 2 percent downward in direction of flow for piping NPS 3 and smaller; 1 percent downward in direction of flow for piping NPS 4 and larger. 2. Horizontal Sanitary Drainage Piping: 2 percent downward in direction of flow. 3. Vent Piping: 1 percent down toward vertical fixture vent or toward vent stack. J. Install engineered soil and waste drainage and vent piping systems as follows: 1. Combination Waste and Vent: Comply with standards of authorities having jurisdiction. 2. Reduced-Size Venting: Comply with standards of authorities having jurisdiction. K. Sleeves are not required for cast-iron soil piping passing through concrete slabs-on-grade if slab is without membrane waterproofing. L. Install PVC soil and waste drainage and vent piping according to ASTM D 2665. M. Install underground PVC soil and waste drainage piping according to ASTM D 2321. SANITARY WASTE AND VENT PIPING 221316-5 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON N. Do not enclose, cover, or put piping into operation until it is inspected and approved by authorities having jurisdiction. 3.4 JOINT CONSTRUCTION A. Basic piping joint construction requirements are specified in Division 23 Section "Basic Mechanical Materials and Methods." B. Join hubless cast-iron soil piping according to CISPI 310 and CISPI's "Cast Iron Soil Pipe and Fittings Handbook" for hubless-coupling joints. C. PVC Nonpressure Piping Joints: Join piping according to ASTM D 2665. 3.5 HANGER AND SUPPORT INSTALLATION A. Seismic-restraint devices are specified in Division 23 Section "Mechanical Vibration Controls and Seismic Restraints." B. Pipe hangers and supports are specified in Division 23 Section "Hangers and Supports." Install the following: 1. Vertical Piping: MSS Type 8 or Type 42,clamps. 2. Install individual,straight,horizontal piping runs according to the following: a. 100 Feet and Less: MSS Type 1,adjustable,steel clevis hangers. b. Longer Than 100 Feet: MSS Type 43,adjustable roller hangers. c. Longer Than 100 Feet,if Indicated: MSS Type 49,spring cushion rolls. 3. Multiple, Straight, Horizontal Piping Runs 100 Feet or Longer: MSS Type 44,pipe rolls. Support pipe rolls on trapeze. 4. Base of Vertical Piping: MSS Type 52,spring hangers. C. Install supports according to Division 23 Section"Hangers and Supports." D. Support vertical piping and tubing at base and at each floor. E. Install hangers for PVC piping with the following maximum horizontal spacing and minimum rod diameters: 1. NPS 1-1/2 and NPS 2: 48 inches with 3/8-inch rod. 2. NPS 3: 48 inches with 1/2-inch rod. 3. NPS 4 and 5: 48 inches with 5/8-inch rod. F. Install supports for vertical PVC piping every 48 inches. G. Support piping and tubing not listed above according to MSS SP-69 and manufacturer's written instructions. SANITARY WASTE AND VENT PIPING 221316-6 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 3.6 CONNECTIONS A. Drawings indicate general arrangement of piping,fittings,and specialties. B. Connect soil and waste piping to exterior sanitary sewerage piping. Use transition fitting to join dissimilar piping materials. C. Connect drainage and vent piping to the following: 1. Plumbing Fixtures: Connect drainage piping in sizes indicated, but not smaller than required by plumbing code. 2. Plumbing Fixtures and Equipment: Connect atmospheric vent piping in sizes indicated, but not smaller than required by authorities having jurisdiction. 3. Plumbing Specialties: Connect drainage and vent piping in sizes indicated, but not smaller than required by plumbing code. 4. Equipment: Connect drainage piping as indicated. Provide shutoff valve, if indicated, and union for each connection. Use flanges instead of unions for connections NPS 2-1/2 and larger. 3.7 FIELD QUALITY CONTROL A. During installation, notify authorities having jurisdiction at least 24 hours before inspection must be made. Perform tests specified below in presence of authorities having jurisdiction. 1. Roughing-in Inspection: Arrange for inspection of piping before concealing or closing-in after roughing-in and before setting fixtures. 2. Final Inspection: Arrange for final inspection by authorities having jurisdiction to observe tests specified below and to ensure compliance with requirements. B. Reinspection: If authorities having jurisdiction find that piping will not pass test or inspection, make required corrections and arrange for reinspection. C. Reports: Prepare inspection reports and have them signed by authorities having jurisdiction. D. Test sanitary drainage and vent piping according to procedures of authorities having jurisdiction or,in absence of published procedures,as follows: 1. Test for leaks and defects in new piping and parts of existing piping that have been altered,extended,or repaired. If testing is performed in segments,submit separate report for each test,complete with diagram of portion of piping tested. 2. Leave uncovered and unconcealed new, altered, extended, or replaced drainage and vent piping until it has been tested and approved. Expose work that was covered or concealed before it was tested. 3. Roughing-in Plumbing Test Procedure: Test drainage and vent piping, except outside leaders, on completion of roughing-in. CIose openings in piping system and fill with water to point of overflow, but not less than 10 foot head of water. From 15 minutes before inspection starts to completion of inspection, water level must not drop. Inspect joints for leaks. SANITARY WASTE AND VENT PIPING 221316-7 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 4. Finished Plumbing Test Procedure: After plumbing fixtures have been set and traps filled with water,test connections and prove they are gastight and watertight. Plug vent- stack openings on roof and building drains where they leave building. Introduce air into piping system equal to pressure of 1 inch wg. Use U-tube or manometer inserted in trap of water closet to measure this pressure. Air pressure must remain constant without introducing additional air throughout period of inspection. Inspect plumbing fixture connections for gas and water leaks. 5. Repair leaks and defects with new materials and retest piping, or portion thereof, until satisfactory results are obtained. 6. Prepare reports for tests and required corrective action. 3.8 CLEANING A. Clean interior of piping. Remove dirt and debris as work progresses. B. Protect drains during remainder of construction period to avoid clogging with dirt and debris and to prevent damage from traffic and construction work. C. Place plugs in ends of uncompleted piping at end of day and when work stops. 3.9 PROTECTION A. Exposed PVC Piping: Protect plumbing vents exposed to sunlight with two coats of water- based latex paint. END OF SECTION 221316 SANITARY WASTE AND VENT PIPING 221316-8 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON SECTION 221319-SANITARY WASTE PIPING SPECIALTIES PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,apply to this Section. 1.2 SUMMARY A. This Section includes the following drainage piping specialties: 1. Cleanouts. 2. Floor drains. 3. Trench drains. 4. Miscellaneous drainage piping specialties. 5. Flashing materials. 1.3 DEFINITIONS A. ABS: Acrylonitrile-butadiene-styrene plastic. B. FOG: Fats,oils,and greases. C. FRP: Fiberglass-reinforced plastic. _ D. HDPE: High-density polyethylene plastic. E. PE: Polyethylene plastic. F. PP: Polypropylene plastic. G. PUR: Polyurethane plastic. H. PVC: Polyvinyl chloride plastic. 1.4 SUBMITTALS A. Product Data: For each type of product indicated. Include rated capacities, operating characteristics,and accessories. B. Field quality-control test reports. SANITARY WASTE PIPING SPECIALTIES 221319- 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON C. Operation and Maintenance Data: For drainage piping specialties to include in operation and maintenance manuals. 1.5 QUALITY ASSURANCE A. Drainage piping specialties shall bear label, stamp, or other markings of specified testing agency. B. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. C. Comply with NSF 14, "Plastics Piping Components and Related Materials," for plastic sanitary and storm piping specialty components. 1.6 COORDINATION A. Coordinate size and location of concrete bases. Cast anchor-bolt inserts into bases. Concrete, reinforcement,and formwork requirements are specified in Division 03. B. Coordinate size and location of roof penetrations. PART 2 -PRODUCTS 2.1 CLEANOUTS A. Exposed Metal-Cleanouts: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Josam Company;Josam Div. b. MIFAB,Inc. c. Smith,Jay R.Mfg.Co.;Division of Smith Industries,Inc. d. Tyler Pipe;Wade Div. e. Watts Drainage Products Inc. f. Zurn Plumbing Products Group; Specification Drainage Operation. 2. Closure: Stainless steel plug with seal. B. Metal Floor Cleanouts: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: SANITARY WASTE PIPING SPECIALTIES 221319-2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON a. Josam Company;Josam Div. b. Oatey. c. Sioux Chief Manufacturing Company,Inc. d. Smith,Jay R.Mfg.Co.;Division of Smith Industries,Inc. e. Tyler Pipe;Wade Div. f. Watts Drainage Products Inc. g. Zum Plumbing Products Group; Specification Drainage Operation. C. Cast-Iron Wall Cleanouts: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Josam Company;Josam Div. b. MIFAB,Inc. c. Smith,Jay R.Mfg.Co.;Division of Smith Industries,Inc. d. Tyler Pipe;Wade Div. e. Watts Drainage Products Inc. f. Zum Plumbing Products Group; Specification Drainage Operation. 2.2 FLOOR DRAINS A. Cast-Iron Floor Drains: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Commercial Enameling Co. b. Josam Company;Josam Div. c. MIFAB,Inc. d. Prier Products,Inc. e. Smith,Jay R.Mfg.Co.;Division of Smith Industries,Inc. f. Tyler Pipe;Wade Div. g. Watts Drainage Products Inc. h. Zurn Plumbing Products Group; Specification Drainage Operation. 2.3 TRENCH DRAINS A. Trench Drains: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Josam Company;Josam Div. b. MIFAB,Inc. SANITARY WASTE PIPING SPECIALTIES 221319-3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85% PERMIT DOCUMENTS TIGARD,OREGON c. Smith,Jay R.Mfg.Co.;Division of Smith Industries,Inc. d. Tyler Pipe;Wade Div. e. Watts Drainage Products Inc. f. Zurn Plumbing Products Group; Specification Drainage Operation. 2.4 MISCELLANEOUS DRAINAGE PIPING SPECIALTIES A. Deep-Seal Traps: 1. Description: Cast-iron or bronze casting,with inlet and outlet matching connected piping and cleanout trap-seal primer valve connection. 2. Size: Same as connected waste piping. a. NPS 2: 4 inch minimum water seal. b. NPS 2-1/2 and Larger: 5 inch minimum water seal. B. Floor-Drain,Trap-Seal Primer Fittings: 1. Description: Cast iron, with threaded inlet and threaded or spigot outlet, and trap-seal primer valve connection. 2. Size: Same as floor drain outlet with NPS 1/2 side inlet. C. Air-Gap Fittings: 1. Standard: ASME A112.1.2,for fitting designed to ensure fixed,positive air gap between installed inlet and outlet piping. 2. Body: Bronze or cast iron. 3. Inlet: Opening in top of body. 4. Outlet: Larger than inlet. 5. Size: Same as connected waste piping and with inlet large enough for associated indirect waste piping. 2.5 FLASHING MATERIALS A. Lead Sheet: ASTM B 749,Type L51121,copper bearing,with the following minimum weights and thicknesses,unless otherwise indicated: 1. General Use: 4.0 lb/sq.ft.,0.0625-inch thickness. 2. Vent Pipe Flashing: 3.0 lb/sq.ft.,0.0469-inch thickness. 3. Burning: 6-1b/sq. ft.,0.0938-inch thickness. B. Copper Sheet: ASTM B 152/B 152M, of the following minimum weights and thicknesses, unless otherwise indicated: 1. General Applications: 12 oz./sq.ft. 2. Vent Pipe Flashing: 8 oz./sq. ft. SANITARY WASTE PIPING SPECIALTIES 221319-4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON C. Zinc-Coated Steel Sheet: ASTM A 653/A 653M, with 0.20 percent copper content and 0.04- inch minimum thickness, unless otherwise indicated. Include G90 hot-dip galvanized, mill- phosphatized finish for painting if indicated. D. Elastic Membrane Sheet: ASTM D 4068, flexible, chlorinated polyethylene, 40 mil minimum thickness. E. Fasteners: Metal compatible with material and substrate being fastened. F. Metal Accessories: Sheet metal strips, clamps, anchoring devices, and similar accessory units required for installation;matching or compatible with material being installed. G. Solder: ASTM B 32,lead-free alloy. H. Bituminous Coating: SSPC-Paint 12,solvent-type,bituminous mastic. PART 3 -EXECUTION 3.1 INSTALLATION A. Refer to Section 230500 "Common Work Results for HVAC" for piping joining materials,joint construction,and basic installation requirements. B. Install cleanouts in aboveground piping and building drain piping according to the following, unless otherwise indicated: 1. Size same as drainage piping up to NPS 4. Use NPS 4 for larger drainage piping unless larger cleanout is indicated. 2. Locate at each change in direction of piping greater than 45 degrees. 3. Locate at minimum intervals of 50 feet for piping NPS 4 and smaller and 100 feet for larger piping. 4. Locate at base of each vertical soil and waste stack. C. For floor cleanouts for piping below floors, install cleanout deck plates with top flush with finished floor. D. For cleanouts located in concealed piping, install cleanout wall access covers, of types indicated,with frame and cover flush with finished wall. E. Install floor drains at low points of surface areas to be drained. Set grates of drains flush with finished floor,unless otherwise indicated. 1. Position floor drains for easy access and maintenance. 2. Set floor drains below elevation of surrounding finished floor to allow floor drainage. Set with grates depressed according to the following drainage area radii: a. Radius,30 Inches or Less: Equivalent to 1 percent slope,but not less than 1/4-inch total depression. SANITARY WASTE PIPING SPECIALTIES 221319-5 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85% PERMIT DOCUMENTS TIGARD,OREGON b. Radius,30 to 60 Inches: Equivalent to 1 percent slope. 3. Install floor-drain flashing collar or flange so no leakage occurs between drain and adjoining flooring. Maintain integrity of waterproof membranes where penetrated. 4. Install individual traps for floor drains connected to sanitary building drain, unless otherwise indicated. F. Install trench drains at low points of surface areas to be drained. Set grates of drains flush with finished surface,unless otherwise indicated. G. Install roof flashing assemblies on sanitary stack vents and vent stacks that extend through roof. H. Install through-penetration firestop assemblies in plastic conductors and stacks at floor penetrations. I. Install deep-seal traps on floor drains and other waste outlets,if indicated. J. Install floor-drain, trap-seal primer fittings on inlet to floor drains that require trap-seal primer connection. K. Install air-gap fittings on draining-type backflow preventers and on indirect-waste piping discharge into sanitary drainage system. L. Install sleeve flashing device with each riser and stack passing through floors with waterproof membrane. M. Install frost-resistant vent terminals on each vent pipe passing through roof. Maintain 1-inch clearance between vent pipe and roof substrate. N. Install expansion joints on vertical stacks and conductors. Position expansion joints for easy access and maintenance. O. Install frost-proof vent caps on each vent pipe passing through roof. Maintain 1-inch clearance between vent pipe and roof substrate. P. Install wood-blocking reinforcement for wall-mounting-type specialties. Q. Install traps on plumbing specialty drain outlets. Omit traps on indirect wastes unless trap is indicated. R. Install escutcheons at wall, floor, and ceiling penetrations in exposed finished locations and within cabinets and millwork. Use deep-pattern escutcheons if required to conceal protruding pipe fittings. 3.2 CONNECTIONS A. Piping installation requirements are specified in other Plumbing Sections. Drawings indicate general arrangement of piping,fittings,and specialties. SANITARY WASTE PIPING SPECIALTIES 221319-6 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON B. Install piping adjacent to equipment to allow service and maintenance. C. Ground equipment according to Section 260526 "Grounding and Bonding for Electrical Systems." D. Connect wiring according to Section 280513 "Conductors and Cables for Electronic Safety." 3.3 FIELD QUALITY CONTROL A. Tests and Inspections: 1. Leak Test: After installation, charge system and test for leaks. Repair leaks and retest until no leaks exist. 2. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and equipment. 3.4 PROTECTION A. Protect drains during remainder of construction period to avoid clogging with dirt or debris and to prevent damage from traffic or construction work. B. Place plugs in ends of uncompleted piping at end of each day or when work stops. END OF SECTION 221319 SANITARY WASTE PIPING SPECIALTIES 221319-7 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON SECTION 223400-FUEL-FIRED DOMESTIC WATER HEATERS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,apply to this Section. 1.2 SUMMARY A. This Section includes the following fuel-fired water heaters: 1. Commercial,high-efficiency,gas water heaters. 2. Water heater accessories. 1.3 DEFINITIONS A. LP Gas:Liquefied-petroleum fuel gas. 1.4 SUBMITTALS A. Product Data: For each type and size of water heater indicated. Include rated capacities, operating characteristics,furnished specialties,and accessories. B. Shop Drawings: Diagram power,signal,and control wiring. C. Product Certificates: For each type of commercial water heater, signed by product manufacturer. D. Manufacturer Seismic Qualification Certification: Submit certification that commercial water heaters, accessories, and components will withstand seismic forces defined in Division 23 Section"Seismic Controls for Plumbing and HVAC."Include the following: 1. Basis for Certification: Indicate whether withstand certification is based on actual test of assembled components or on calculation. a. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces specified." 2. Detailed description of equipment anchorage devices on which the certification is based and their installation requirements. E. Source quality-control test reports. FUEL-FIRED DOMESTIC WATER HEATERS 223400- 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON F. Field quality-control test reports. G. Operation and Maintenance Data: For water heaters to include in emergency, operation, and maintenance manuals. H. Warranty: Special warranty specified in this Section. 1.5 QUALITY ASSURANCE A. Source Limitations: Obtain same type of water heaters through one source from a single manufacturer. B. Product Options: Drawings indicate size, profiles, and dimensional requirements of water heaters and are based on the specific system indicated. Refer to Division 01 Section "Product Requirements." C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. D. ASME Compliance: 1. Where ASME-code construction is indicated,fabricate and label commercial water heater storage tanks to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. 2. Where ASME-code construction is indicated,fabricate and label commercial,finned-tube water heaters to comply with ASME Boiler and Pressure Vessel Code: Section N. E. Comply with NSF 61, "Drinking Water System Components - Health Effects; Sections 1 through 9"for all components that will be in contact with potable water. 1.6 COORDINATION A. Coordinate size and location of concrete bases with Architectural and Structural Drawings. 1.7 WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of fuel-fired water heaters that fail in materials or workmanship within — specified warranty period. 1. Failures include,but are not limited to,the following: a. Structural failures including storage tank and supports. b. Faulty operation of controls. c. Deterioration of metals,metal fmishes,and other materials beyond normal use. 2. Warranty Period(s): From date of Substantial Completion: FUEL-FIRED DOMESTIC WATER HEATERS 223400-2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON a. Commercial,Gas Water Heaters: 1) Storage Tank: Three years. 2) Controls and Other Components: Three years. b. Compression Tanks: One year. PART 2-PRODUCTS 2.1 MANUFACTURERS A. In other Part 2 articles where titles below introduce lists, the following requirements apply to product selection: 1. Manufacturers: Subject to compliance with requirements. Provide products by one of the manufacturers specified. 2.2 COMMERCIAL,GAS WATER HEATERS A. Commercial,High-Efficiency,Gas Water Heaters: Comply with ANSI Z21.10.3/CSA 4.3. 1. Manufacturer: a. EVO. 2. Description: Manufacturer's proprietary design to provide at least 95 percent combustion efficiency at optimum operating conditions. Following features and attributes may be modified or omitted if water heater otherwise complies with requirements for performance. 3. Storage-Tank Construction: ASME-code steel with 150-psig minimum working-pressure rating. a. Tappings: Factory fabricated of materials compatible with tank. Attach tappings to tank before testing. 1) NPS 2 and Smaller: Threaded ends according to ASME B1.20.1. 2) NPS 2-1/2 and Larger: Flanged ends according to ASME B16.5 for steel and stainless-steel flanges, and according to ASME B16.24 for copper and copper-alloy flanges. b. Interior Finish: Comply with NSF 61 barrier materials for potable-water tank linings,including extending finish into and through tank fittings and outlets. c. Lining: Glass complying with NSF 61 barrier materials for potable-water tank linings,including extending lining into and through tank fittings and outlets. 4. Factory-Installed, Storage-Tank Appurtenances: a. Anode Rod: Replaceable magnesium. FUEL-FIRED DOMESTIC WATER HEATERS 223400-3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85% PERMIT DOCUMENTS TIGARD,OREGON b. Dip Tube: Provide unless cold-water inlet is near bottom of tank. c. Drain Valve: Corrosion-resistant metal complying with ASSE 1005. d. Insulation: Comply with ASHRAE/IESNA 90.1. Surround entire storage tank except connections and controls. e. Jacket: Steel with enameled finish. f. Combination Temperature and Pressure Relief Valves: ANSI Z21.22/CSA 4.4. Include one or more relief valves with total relieving capacity at least as great as heat input, and include pressure setting less than water heater working-pressure rating. Select one relief valve with sensing element that extends into storage tank. 5. Burner or Heat Exchanger: Comply with UL 795 or approved testing agency requirements for high-efficiency water heaters and for natural-gas fuel. 6. Temperature Control: Adjustable thermostat. 7. Safety Controls: Automatic, high-temperature-limit and low-water cutoff devices or systems. 2.3 WATER HEATER ACCESSORIES A. Gas Shutoff Valves: ANSI Z21.15/CGA 9.1, manually operated. Furnish for installation in piping. B. Gas Automatic Valves: ANSI Z21.21,appliance,electrically operated,on-off automatic valve. C. Combination Temperature and Pressure Relief Valves: Include relieving capacity at least as great as heat input,and include pressure setting less than water heater working-pressure rating. Select each relief valve with sensing element that extends into storage tank. 1. Gas Water Heaters: ANSI Z21.22/CSA 4.4. D. Pressure Relief Valves: Include pressure setting less than working-pressure rating of water heater. 1. Gas Water Heaters: ANSI Z21.22/CSA 4.4. E. Drain Pans: Corrosion-resistant metal with raised edge. Provide dimensions not less than base of water heater and include drain outlet not less than NPS 3/4. F. Piping Manifold Kits: Water heater manufacturer's factory-fabricated inlet and outlet piping arrangement for multiple-unit installation. Include piping and valves for field assembly that is capable of isolating each water heater and of providing balanced flow through each water heater. 2.4 SOURCE QUALITY CONTROL A. Test and inspect water heater storage tanks,specified to be ASME-code construction,according to ASME Boiler and Pressure Vessel Code. FUEL-FIRED DOMESTIC WATER HEATERS 223400-4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON B. Hydrostatically test commercial water heater storage tanks before shipment to minimum of one and one-half times pressure rating. C. Prepare test reports. PART 3-EXECUTION 3.1 WATER HEATER INSTALLATION A. Install commercial water heaters on concrete bases. 1. Exception: Omit concrete bases for commercial water heaters if installation on stand, bracket,suspended platform,or direct on floor is indicated. 2. Concrete base construction requirements are specified in Division 23 Section "Common Work Results for HVAC." B. Install water heaters level and plumb, according to layout drawings, original design, and referenced standards. Maintain manufacturer's recommended-clearances. Arrange units so controls and devices needing service are accessible. C. Install seismic restraints for commercial water heaters. Anchor to substrate. D. Install gas water heaters according to NFPA 54. E. Install gas shutoff valves on gas supplies to gas water heaters without shutoff valves. F. Install gas pressure regulators on gas supplies to gas water heaters without gas pressure regulators if gas pressure regulators are required to reduce gas pressure at burner. G. Install automatic gas valves on gas supplies to gas water heaters, if required for operation of safety control. H. Install combination temperature and pressure relief valves in top portion of storage tanks. Use relief valves with sensing elements that extend into tanks. Extend commercial-water-heater, relief-valve outlet, with drain piping same as domestic water piping in continuous downward pitch,and discharge by positive air gap onto closest floor drain. I. Install combination temperature and pressure relief valves in water piping for water heaters without storage. Extend commercial-water-heater relief-valve outlet, with drain piping same as domestic water piping in continuous downward pitch, and discharge by positive air gap onto closest floor drain. J. Install water heater drain piping as indirect waste to spill by positive air gap into open drains or over floor drains. Install hose-end drain valves at low points in water piping for water heaters that do not have tank drains. K. Install thermometer on outlet piping of water heaters. Refer to Division 23 Section"Meters and Gages for HVAC Piping"for thermometers. FUEL-FIRED DOMESTIC WATER HEATERS 223400-5 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON L. Install pressure gage on outlet piping of commercial, fuel-fired water heater piping. Refer to Division 23 Section"Meters and Gages for HVAC Piping"for pressure gages. M. Assemble and install inlet and outlet piping manifold kits for multiple water heaters. Fabricate, modify, or arrange manifolds for balanced water flow through each water heater. Include shutoff valve and thermometer in each water heater inlet and outlet,and throttling valve in each water heater outlet. Refer to Division 23 Section"General-Duty Valves for HVAC Piping" for general-duty valves and to Division 23 Section "Meters and Gages for HVAC Piping" for thermometers. N. Fill water heaters with water. O. Charge compression tanks with air. 3.2 CONNECTIONS A. Piping installation requirements are specified in other related Sections. Drawings indicate general arrangement of piping,fittings,and specialties. B. Install piping adjacent to water heaters to allow service and maintenance. Arrange piping for easy removal of water heaters. C. Ground equipment according to Division 26 Section "Grounding and Bonding for Electrical Systems." D. Connect wiring according to Division 28 Section"Conductors and Cables for Electronic Safety and Security." 3.3 FIELD QUALITY CONTROL A. Perform the following field tests and inspections and prepare test reports: 1. Leak Test: After installation,test for leaks. Repair leaks and retest until no leaks exist. 2. Operational Test: After electrical circuitry has been energized,confirm proper operation. 3. Test and adjust controls and safeties. Replace damaged and malfunctioning controls and equipment. B. Remove and replace water heaters that do not pass tests and inspections and retest as specified above. END OF SECTION 223400 FUEL-FIRED DOMESTIC WATER HEATERS 223400-6 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON SECTION 224000-PLUMBING FIXTURES PART I -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,apply to this Section. 1.2 SUMMARY A. This Section includes the following conventional plumbing fixtures and related components: 1. Faucets for lavatories and sinks. 2. Laminar-flow faucet-spout outlets. 3. Flushometers. 4. Toilet seats. 5. Protective shielding guards. 6. Fixture supports. 7. Dishwasher air-gap fittings. 8. Water closets. 9. Urinals. 10. Lavatories. 11. Commercial sinks. 12. Kitchen sinks. 13. Service sinks. 1.3 SUBMITTALS A. Product Data: For each type of plumbing fixture indicated. Include selected fixture and trim, fittings, accessories, appliances, appurtenances, equipment, and supports. Indicate materials and finishes,dimensions,construction details,and flow-control rates. B. Shop Drawings: Diagram power,signal,and control wiring. C. Operation and Maintenance Data: For plumbing fixtures to include in emergency, operation, and maintenance manuals. D. Warranty: Special warranty specified in this Section. 1.4 QUALITY ASSURANCE A. Source Limitations: Obtain plumbing fixtures, faucets, and other components of each category through one source from a single manufacturer. PLUMBING FIXTURES 224000- 1 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 1. Exception: If fixtures, faucets, or other components are not available from a single manufacturer, obtain similar products from other manufacturers specified for that category. B. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. C. Regulatory Requirements: Comply with requirements in ICC A117.1, "Accessible and Usable Buildings and Facilities";Public Law 90-480, "Architectural Barriers Act"; and Public Law 101-336, "Americans with Disabilities Act"; for plumbing fixtures for people with disabilities. D. Regulatory Requirements: Comply with requirements in Public Law 102-486, "Energy Policy Act,"about water flow and consumption rates for plumbing fixtures. E. NSF Standard: Comply with NSF 61, "Drinking Water System Components--Health Effects," for fixture materials that will be in contact with potable water. F. Select combinations of fixtures and trim, faucets, fittings, and other components that are compatible. G. Comply with the following applicable standards and other requirements specified for plumbing fixtures: 1. Enameled,Cast-Iron Fixtures: ASME A112.19.1M. 2. Plastic Mop-Service Basins: ANSI Z124.6. 3. Porcelain-Enameled,Formed-Steel Fixtures: ASME A112.19.4M. 4. Solid-Surface-Material Lavatories and Sinks: ANSI/ICPA SS-1. 5. Stainless-Steel Commercial,Handwash Sinks: NSF 2 construction. 6. Stainless-Steel Residential Sinks: ASME A112.19.3. 7. Vitreous-China Fixtures: ASME A112.19.2M. 8. Water-Closet,Flush Valve,Tank Trim: ASME A112.19.5. 9. Whirlpool Bathtub Fittings: ASME Al 12.19.8M. H. Comply with the following applicable standards and other requirements specified for lavatory and sink faucets: 1. Backflow Protection Devices for Faucets with Side Spray: ASME A112.18.3M. 2. Backflow Protection Devices for Faucets with Hose-Thread Outlet: ASME Al 12.18.3M. 3. Diverter Valves for Faucets with Hose Spray: ASSE 1025. 4. Faucets: ASME A112.18.1. 5. Hose-Connection Vacuum Breakers: ASSE 1011. 6. Hose-Coupling Threads: ASME 81.20.7. 7. Integral,Atmospheric Vacuum Breakers: ASSE 1001. 8. NSF Potable-Water Materials: NSF 61. 9. Pipe Threads: ASME B1.20.1. 10. Sensor-Actuated Faucets and Electrical Devices: UL 1951. 11. Supply Fittings: ASME A112.18.1. 12. Brass Waste Fittings: ASME A112.18.2. PLUMBING FIXTURES 224000-2 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON I. Comply with the following applicable standards and other requirements specified for miscellaneous fittings: 1. Atmospheric Vacuum Breakers: ASSE 1001. 2. Brass and Copper Supplies: ASME A112.18.1. 3. Dishwasher Air-Gap Fittings: ASSE 1021. 4. Manual-Operation Flushometers: ASSE 1037. 5. Plastic Tubular Fittings: ASTM F 409. 6. Brass Waste Fittings: ASME A112.18.2. 7. Sensor-Operation Flushometers: ASSE 1037 and UL 1951. J. Comply with the following applicable standards and other requirements specified for miscellaneous components: 1. Disposers: ASSE 1008 and UL 430. 2. Dishwasher Air-Gap Fittings: ASSE 1021. 3. Flexible Water Connectors: ASME A112.18.6. 4. Floor Drains: ASME A112.6.3. 5. Grab Bars: ASTM F 446. 6. Hose-Coupling Threads: ASME B1.20.7. 7. Hot-Water Dispensers: ASSE 1023 and UL 499. 8. Off-Floor Fixture Supports: ASME A112.6.1M. 9. Pipe Threads: ASME B1.20.1. 10. Plastic Shower Receptors: ANSI Z124.2. 11. Plastic Toilet Seats: ANSI Z124.5. 12. Supply and Drain Protective Shielding Guards: ICC A117.1. 13. Whirlpool Bathtub Equipment: UL 1795. 1.5 WARRANTY A. Special Warranties: Manufacturer's standard form in which manufacturer agrees to repair or replace components of whirlpools that fail in materials or workmanship within specified warranty period. 1. Failures include,but are not limited to,the following: a. Structural failures of unit shell. b. Faulty operation of controls,blowers,pumps,heaters,and timers. c. Deterioration of metals,metal finishes,and other materials beyond normal use. 2. Warranty Period for Commercial Applications: One year from date of Substantial Completion. PLUMBING FIXTURES 224000-3 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON PART 2-PRODUCTS 2.1 LAVATORY FAUCETS A. Lavatory Faucets: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. American Standard Companies,Inc. b. Bradley Corporation. c. Chicago Faucets. d. Delta Faucet Company. e. Eljer. f. Elkay Manufacturing Co. g. Fisher Manufacturing Co. h. Geberit Manufacturing,Inc. i. Grohe America,Inc. j. Just Manufacturing Company. k. Kohler Co. 1. Moen,Inc. m. Royal Brass Mfg.Co. n. Sayco;a Briggs Plumbing Products,Inc.Company. o. Speakman Company. p. T&S Brass and Bronze Works,Inc. q. TOTO USA,Inc. r. Zurn Plumbing Products Group;Commercial Brass Operation. 2. Description: Single-control mixing valve. Include hot- and cold-water indicators; coordinate faucet inlets with supplies and fixture holes; coordinate outlet with spout and fixture receptor. 2.2 SINK FAUCETS A. Sink Faucets: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. American Standard Companies,Inc. b. Bradley Corporation. c. Broadway Collection. d. Chicago Faucets. e. Delta Faucet Company. f. Dormont Manufacturing Company. g. Eljer. PLUMBING FIXTURES 224000-4 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON h. Elkay Manufacturing Co. i. Fisher Manufacturing Co. j. Geberit Manufacturing,Inc. k. Grohe America,Inc. 1. Just Manufacturing Company. m. Kohler Co. n. Moen,Inc. o. Royal Brass Mfg.Co. - p. Sayco;a Briggs Plumbing Products,Inc.Company. q. Speakman Company. r. T& S Brass and Bronze Works,Inc. s. Zurn Plumbing Products Group;Commercial Brass Operation. 2. Description: Kitchen faucet with spray, four-hole fixture. Include hot- and cold-water indicators; coordinate faucet inlets with supplies and fixture holes; coordinate outlet with spout and fixture receptor. 2.3 FLUSHOMETERS A. Flushometers: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Coyne&Delany Co. b. Delta Faucet Company. c. Geberit Manufacturing,Inc. d. Sloan Valve Company. e. Zurn Plumbing Products Group;Commercial Brass Operation. 2. Description: Flushometer for urinal and water-closet-type fixture. Include brass body with corrosion-resistant internal components, non-hold-open feature, control stop with check valve, vacuum breaker, copper or brass tubing, and polished chrome-plated finish on exposed parts. 2.4 TOILET SEATS A. Toilet Seats: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Bemis Manufacturing Company. b. Centoco Manufacturing Corp. c. Church Seats. ' d. Kohler Co. PLUMBING FIXTURES 224000-5 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON e. Olsonite Corp. f. Pressalit A/S. g. Sanderson Plumbing Products,Inc.;Beneke Div. h. Sperzel. 2.5 PROTECTIVE SHIELDING GUARDS A. Protective Shielding Pipe Covers: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Engineered Brass Co. b. Insul-Tect Products Co.;a Subsidiary of MVG Molded Products. c. McGuire Manufacturing Co.,Inc. d. Plumberex Specialty Products Inc. e. TCI Products. f. TRUEBRO,Inc. - g. Zurn Plumbing Products Group;Tubular Brass Plumbing Products Operation. B. Protective Shielding Piping Enclosures: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. McGuire Manufacturing Co.,Inc. b. Plumberex Specialty Products,Inc. c. TRUEBRO,Inc. - 2. Description: Manufactured plastic enclosure for covering plumbing fixture hot- and cold-water supplies and trap and drain piping. Comply with ADA requirements. 2.6 FIXTURE SUPPORTS A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to,the following: 1. Josam Company. 2. MIFAB Manufacturing Inc. 3. Smith,Jay R. Mfg.Co. 4. Tyler Pipe;Wade Div. 5. Watts Drainage Products Inc.;a div.of Watts Industries,Inc. 6. Zurn Plumbing Products Group; Specification Drainage Operation. B. Water-Closet Supports: PLUMBING FIXTURES 224000-6 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 1. Description: Combination carrier designed for accessible and standard mounting height of wall-mounting, water-closet-type fixture. Include single or double, vertical or horizontal, hub-and-spigot or hubless waste fitting as required for piping arrangement; faceplates; couplings with gaskets; feet; and fixture bolts and hardware matching fixture. Include additional extension coupling, faceplate, and feet for installation in wide pipe space. C. Urinal Supports: 1. Description: Type I,urinal carrier with fixture support plates and coupling with seal and fixture bolts and hardware matching fixture for wall-mounting, urinal-type fixture. Include steel uprights with feet. 2. Accessible-Fixture Support: Include rectangular steel uprights. D. Lavatory Supports: 1. Description: Type II,lavatory carrier with concealed arms and tie rod for wall-mounting, lavatory-type fixture. Include steel uprights with feet. 2. Accessible-Fixture Support: Include rectangular steel uprights. 2.7 DISHWASHER AIR-GAP FITTINGS A. Dishwasher Air-Gap Fittings: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. B&K Industries,Inc. b. Brass Craft Mfg.Co.;a Subsidiary of Masco Corporation. c. Brasstech Inc.;Newport Brass Div. d. Dearborn Brass;a div.of Moen,Inc. e. Geberit Manufacturing,Inc. f. JB Products;a Federal Process Corporation Company. g. Sioux Chief Manufacturing Company,Inc. h. Watts Brass&Tubular;a division of Watts Regulator Co. 2. Description: Fitting suitable for use with domestic dishwashers and for deck mounting; with plastic body, chrome-plated brass cover; and capacity of at least 5 gpm; and inlet pressure of at least 5 psig at a temperature of at least 140 deg F. Include 5/8-inch ID inlet and 7/8-inch ID outlet hose connections. 3. Hoses: Rubber and suitable for temperature of at least 140 deg F. a. Inlet Hose: 5/8-inch ID and 48 inches long. b. Outlet Hose: 7/8-inch ID and 48 inches long. PLUMBING FIXTURES 224000-7 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 2.8 WATER CLOSETS A. Water Closets: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: a. American Standard Companies, Inc. b. Briggs Plumbing Products, Inc. c. Capizzi. d. Crane Plumbing,L.L.C./Fiat Products. e. Eljer. f. Kohler Co. g. St.Thomas Creations. h. TOTO USA, Inc. i. Zurn Plumbing Products Group; Commercial Brass Operation. 2. Description Accessible, wall and wall-mounting, back-outlet, vitreous-china fixture designed for flushometer valve operation. 2.9 URINALS A. Urinals: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: a. American Standard Companies, Inc. b. Briggs Plumbing Products,Inc. c. Capizzi. d. Crane Plumbing, L.L.C./Fiat Products. e. Duravit USA, Inc. f. Eljer. g. Kohler Co. h. Mansfield Plumbing Products, Inc. i. Peerless Pottery, Inc. J. Sanitarios Azteca, S.A. de C.V. k. St.Thomas Creations. 1. TOTO USA, Inc. m. Zurn Plumbing Products Group; Commercial Brass Operation. 2. Description: Accessible, wall and wall-mounting, back-outlet, vitreous-china fixture designed for flushometer valve operation. PLUMBING FIXTURES 224000-8 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 2.10 LAVATORIES A. Lavatories: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. American Standard Companies,Inc. b. Barclay Products,Ltd. c. Briggs Plumbing Products,Inc. d. Crane Plumbing,L.L.C./Fiat Products. e. Eljer. f. Gerber Plumbing Fixtures LLC. ■ g. Kohler Co. h. Mansfield Plumbing Products,Inc. i. Peerless Pottery,Inc. j. Sterling Plumbing Group,Inc. k. St.Thomas Creations. 1. TOTO USA,Inc. 2. Description: Accessible,wall and wall-mounting,vitreous-china fixture. B. Lavatories: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Acorn Engineering Company. b. American Standard Companies,Inc. c. Barclay Products,Ltd. d. Briggs Plumbing Products,Inc. e. Crane Plumbing,L.L.C./Fiat Products. f. Eljer. g. Elkay Manufacturing Co. h. Gerber Plumbing Fixtures LLC. i. Intersan Manufacturing Company. j. Just Manufacturing Company. k. Kohler Co. 1. Mansfield Plumbing Products,Inc. m. Peerless Pottery,Inc. n. Sterling Plumbing Group,Inc. o. St.Thomas Creations. p. TOTO USA,Inc. q. Zurn Plumbing Products Group;Commercial Brass Operation. + 2. Description: Accessible, counter-mounting and undercounter-mounting stainless-steel, vitreous-china fixture. PLUMBING FIXTURES 224000-9 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON C. Lavatories: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. American Standard Companies,Inc. - b. Briggs Plumbing Products,Inc. c. Crane Plumbing,L.L.C./Fiat Products. d. Eljer. e. Kohler Co. f. Mansfield Plumbing Products,Inc. g. Peerless Pottery,Inc. h. St.Thomas Creations. 2. Description: Accessible, wall-mounting, vitreous-china fixture designed for people in wheelchairs. 2.11 COMMERCIAL SINKS A. Commercial Sinks: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Advance Tabco. b. Elkay Manufacturing Co. c. Just Manufacturing Company. d. Metal Masters Foodservice Equipment Co.,Inc. 2. Description: Two-compartment, counter-mounting, stainless-steel commercial sink with backsplash. 2.12 KITCHEN SINKS A. Kitchen Sinks: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: a. Dayton Products,Inc. b. Elkay Manufacturing Co. c. Franke Consumer Products,Inc.,Kitchen Systems Div. d. Just Manufacturing Company. e. Kohler Co. f. Moen,Inc. PLUMBING FIXTURES 224000- 10 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON g. Revere Sink. h. Sterling Plumbing Group, Inc. i. Teka USA. j. WhiteRock Corp. 2. Description: Two-bowl,residential,counter-mounting,stainless-steel kitchen sink. 2.13 SERVICE SINKS A. Service Sinks: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: a. American Standard Companies, Inc. b. Commercial Enameling Company. c. Eljer. d. Kohler Co. e. Zurn Plumbing Products Group; Commercial Brass Operation. 2. Description: Trap-standard- and wall-mounting, vitreous-china fixture with two faucet holes in back and rim guard on front and sides. 2.14 SERVICE BASINS A. Service Basins: 1. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include,but are not limited to, the following: a. Acorn Engineering Company. b. Crane Plumbing,L.L.C./Fiat Products. c. Florestone Products Co.,Inc. d. Mustee,E. L. & Sons, Inc. e. Precast Terrazzo Enterprises,Inc. f. Stern-Williams Co., Inc. g. Swan Corporation(The). h. Zurn Plumbing Products Group; Light Commercial Operation. 2. Description: Flush-to-wall, floor-mounting,precast terrazzo or cast-polymer fixture with rim guard. PLUMBING FIXTURES 224000- 11 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON PART 3-EXECUTION 3.1 EXAMINATION A. Examine roughing-in of water supply and sanitary drainage and vent piping systems to verify actual locations of piping connections before plumbing fixture installation. B. Examine cabinets, counters, floors, and walls for suitable conditions where fixtures will be installed. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. Assemble plumbing fixtures, trim, fittings, and other components according to manufacturers' written instructions. B. Install off-floor supports,affixed to building substrate,for wall-mounting fixtures. 1. Use carrier supports with waste fitting and seal for back-outlet fixtures. 2. Use carrier supports without waste fitting for fixtures with tubular waste piping. 3. Use chair-type carrier supports with rectangular steel uprights for accessible fixtures. C. Install back-outlet,wall-mounting fixtures onto waste fitting seals and attach to supports. D. Install floor-mounting fixtures on closet flanges or other attachments to piping or building substrate. E. Install wall-mounting fixtures with tubular waste piping attached to supports. F. Install counter-mounting fixtures in and attached to casework. G. Install fixtures level and plumb according to roughing-in drawings. H. Install water-supply piping with stop on each supply to each fixture to be connected to water distribution piping. Attach supplies to supports or substrate within pipe spaces behind fixtures. Install stops in locations where they can be easily reached for operation. 1. Exception: Use ball, gate, or globe valves if supply stops are not specified with fixture. Valves are specified in Section 230523 "General-Duty Valves for HVAC Piping." I. Install trap and tubular waste piping on drain outlet of each fixture to be directly connected to sanitary drainage system. J. Install tubular waste piping on drain outlet of each fixture to be indirectly connected to drainage system. PLUMBING FIXTURES 224000- 12 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85% PERMIT DOCUMENTS TIGARD,OREGON K. Install flushometer valves for accessible water closets and urinals with handle mounted on wide side of compartment. Install other actuators in locations that are easy for people with disabilities to reach. L. Install toilet seats on water closets. M. Install faucet-spout fittings with specified flow rates and patterns in faucet spouts if faucets are not available with required rates and patterns. Include adapters if required. N. Install water-supply flow-control fittings with specified flow rates in fixture supplies at stop valves. O. Install faucet flow-control fittings with specified flow rates and patterns in faucet spouts if faucets are not available with required rates and patterns. Include adapters if required. P. Install traps on fixture outlets. 1. Exception: Omit trap on fixtures with integral traps. 2. Exception: Omit trap on indirect wastes,unless otherwise indicated. Q. Install dishwasher air-gap fitting at each sink indicated to have air-gap fitting. Install in sink deck. Connect inlet hose to dishwasher and outlet hose to disposer. R. Install escutcheons at piping wall ceiling penetrations in exposed, finished locations and within cabinets and millwork. Use deep-pattern escutcheons if required to conceal protruding fittings. Escutcheons are specified in Section 230500"Common Work Results for HVAC." S. Set service basins in leveling bed of cement grout. Grout is specified in Section 230500 "Common Work Results for HVAC." T. Seal joints between fixtures and walls, floors, and countertops using sanitary-type, one-part, mildew-resistant silicone sealant. Match sealant color to fixture color. Sealants are specified in Division 07 Section"Joint Sealants." 3.3 CONNECTIONS A. Piping installation requirements are specified in other related Sections. Drawings indicate general arrangement of piping,fittings,and specialties. B. Connect fixtures with water supplies, stops, and risers, and with traps, soil, waste, and vent piping. Use size fittings required to match fixtures. C. Ground equipment according to Section 260526 "Grounding and Bonding for Electrical Systems." D. Connect wiring according to Section 280513 "Conductors and Cables for Electronic Safety and Security." PLUMBING FIXTURES 224000- 13 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON 3.4 FIELD QUALITY CONTROL A. Verify that installed plumbing fixtures are categories and types specified for locations where installed. B. Check that plumbing fixtures are complete with trim, faucets, fittings, and other specified components. ,t C. Inspect installed plumbing fixtures for damage. Replace damaged fixtures and components. D. Test installed fixtures after water systems are pressurized for proper operation. Replace malfunctioning fixtures and components, then retest. Repeat procedure until units operate properly. E. Install fresh batteries in sensor-operated mechanisms. 3.5 ADJUSTING A. Operate and adjust faucets and controls. Replace damaged and malfunctioning fixtures,fittings, and controls. B. Operate and adjust controls. Replace damaged and malfunctioning units and controls. C. Adjust water pressure at faucets and flushometer valves to produce proper flow and stream. D. Replace washers and seals of leaking and dripping faucets and stops. E. Install fresh batteries in sensor-operated mechanisms. 3.6 CLEANING A. Clean fixtures, faucets, and other fittings with manufacturers' recommended cleaning methods and materials. Do the following: 1. Remove faucet spouts and strainers, remove sediment and debris, and reinstall strainers and spouts. 2. Remove sediment and debris from drains. B. After completing installation of exposed, factory-finished fixtures, faucets, and fittings, inspect exposed finishes and repair damaged finishes. 3.7 PROTECTION A. Provide protective covering for installed fixtures and fittings. PLUMBING FIXTURES 224000- 14 WHOLE FOODS MARKET-GREENWAY TOWN CENTER WFGNW TENANT IMPROVEMENTS 85%PERMIT DOCUMENTS TIGARD,OREGON B. Do not allow use of plumbing fixtures for temporary facilities unless approved in writing by Owner. END OF SECTION 224000 PLUMBING FIXTURES 224000- 15