Permit a CITY OF TIGARD MECHANICAL PERMIT 14 — COMMUNITY DEVELOPMENT Permit#: MEC2014-00394 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 09/02/2014 Parcel: 2S102CC00500 Jurisdiction: Tigard Site address: 13500 SW PACIFIC HWY 30 Project: !chi Teriyaki Subdivision: FREWING'S ORCHARD TRACTS Lot: 15 Project Description: Install Type I hood,a walk-in cooler,(2)vent fans and gas piping. Contractor: MUTUAL INDUSTRIES INC Owner: ROIC OREGON LLC 1605 S 93RD ST, UNIT ES 8905 TOWNE CENTRE DR, STE 108 SEATTLE,WA 98108 SAN DIEGO,CA 92122 PHONE: 206-767-6647 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 09/02/2014 $754.11 Class of Work: ALT Type of Const: VB Plan Review 09/02/2014 $188.53 Occupancy Grp: A-2 Occupancy Load: 12%State Surcharge-Mechanical 09/02/2014 $90.49 Stories: 1 Info Process/Archiving-Sm$0.50(up to 09/02/2014 $5.00 11x17) Project Valuation: $26,000.00 Fuel Air Handlers Fuel Types: Units< 10000 cfm: 1 Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces<100K BTU: 0-3 HP: Furnaces>=100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $1,038.13 Hoods: Comm Incinerators: Woodstoves: Gas Fireplaces: Required Items and Reports(Conditions) Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: Walk in Duct Work: cooler Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. Yo may obtain a copy of t - rules or direct qu to�UNC by calling 503.232.1987 or 1.800.332.2344. Issued B u Permittee Signature: '. =_�- Call 503.639.4175 by 7:00 a.m.for the next available ins.t ion date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit App1MIECEIVED 10I< ()1 1 1( 1 1 `,1 I1v 1 1 City of Tigard Received r`(c{ 40 Permit No.://EC 5/ et93e • 13125 SW Hall Blvd.,Tigard,OR 9722 ► II Phone: 503.718.2439 Fax: 503.598.1 L 2 9 2014 014 Plan Review Date/By: ,S_'/,11 i4 I Other Permit: I`I) Inspection Line: 503.639.4175 Date Ready/By: p • Juris ® See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: �7 �� Supplemental Information TYPE OFING DIVISION "4«`� COMMERCIAL FEE* SCHEDULE — USE CHECKLIST Mechanical permit fees*are based on the value of the work ❑New construction Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,ov, rhead,and profit. Value:S r CZX I _- CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ❑ I-and 2-family dwelling XCommercial/industrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder ❑Other: Description I Qty. I Ea. I Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 46.75 Job site address: / 7 5, j7 � )t ) Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: .'�%ate 0 r, g� �13 Furnace 100,000+BTU(ducts/vents) 54.91 10"" t Heat pump 61.06 Suite/bldg./apt.no.: 7,0 Project name: i_ 'r �C�1 Duct work 23.32 Cross street/directions to job site: l Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision: I Lot no.: Other: 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas Tni 5-0EIll • ,0 /3/ --9 p 1 hoed r T-n s tiza fireplace 23.32 p L Log lighter(gas) 23.32 7l a 1) vn COO!e,ri o.set 3� '�T.!'C ))Ct7141t Wood/pellet stove 33.39 MD'YL IsGto _e Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ❑ PROPERTY OWNER 1 ❑ TENANT Other:Envir 23.32 Environmental exhaust and ventilation: Name: Range hood/other kitchen equipment 33.39 Address: Clothes dryer exhaust 33.39 City/State/ZIP: Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:( ) Fax:( ) Attic/crawlspace fans 23.32 ' PPLICANT ❑ CONTACT PERSON Other: 23.32 `n Fuel piping: Business name: A,4 L l/ l'imv5;r��O,J 4 21,af�f 6/V /A/G $14.15 for first four;$4.03 for each additional Contact name: J<,EN � ,,L / Furnace,etc. Address: c2 73� .SE p `- �!l�L I r ?iv/ —6 Gas heat pump . Wall/suspended/unit heater City/State/ZIP: r 4724,1` ox_ 97 a4(o Water heater Y 0 7/ Fireplace Phone:(503) 3 �— Fax::( ) Range E-mail: - Barbecue CONTRACTOR Clothes dryer(gas) /� Other: Business name: tA,- a1 ,t�,64(e //�/` MECHANICAL PERM1 FEES* Address: /eZ0S- s R; I v` 5 ' Subtotal — City/State/ZIP: Se64-j/ LZey 1f1L8 Minimum permit fee($90.00) / Plan review(25%of permit fee) _ Phone:(d(,) 6 7_6 G y7 Fax:( ) State surcharge(12%of permit fee) CCB lie.: /`1 q/ 2__ 3/gyp /s TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 ' days after it has been accepted as complete. Authorized signature: r. �� * Fee methodology set by Tri-County Building Industry Service Board Print name: �A�!!/ +�+�o Date: I:\BuildingW ermits\MEC_PermitApp_040011•3.dooe 440-4617T(1 I/02JCOM/WEB) 6" MAC.. 1-5/8"x2" UNISTRUT SECURED X ix _//,_ TO TRUSSES WITH #16 SCREWS I � ' V 3/8"-16 HEAVY DUTY LOCK NUT 3/8"-16 ALL THREAD RODS © 3' ON CENTER ONE ABOVE AND ONE BELOW SECURED HOOD W/ #16 SCREWS AT EVERY STUDS CITY OPTIGARD / REVIEWED FOR CODE COMPLIANCE Approved: I l--r- • n OTC: I U permit#: t ti 1- _c2C14-Go Address: F. i Zit /H Suite#: .) ( mac I By: Dates 21, 14 • . 0 OFFICE COPY KALY CONSTRUCTION & DESIGN INC. 2738 SE 82ND AVE SUITE 201-D Portland. Oregon 97269 PHONE:509 948-0712 PAL 509 775-2117 ICHI TERIYAKI RESTAURANT #25 13D00 SR PACIFIC HAY SmL. #30 T 2 G A R D. O R HOOD HANGER DETAILS DATE: 8/14/14 BY: KJY SCALE: N.T.S. # SK1 WALK-IN GOOIER ANCHOR zz, 4 PLACES TYP. NEW WALL WALK—IN COOLER , n p tFLOOR PLAN 3"X3" STEEL ANGLE WALK—IN COOLER WALL 5/8" DIA. BOLT 5/8" DIA. EXPANSION BOLT WITH MIN. 3" IN CONC. o as a , EXIST. CONC. SLAB d SECTION AT ANCHOR KALY CONSTRUCTION & DESIGN INC. 2738 SE 82ND AVE SUITE 201-D Portland. Oregon 97298 • PHONE 503 348-0712 YID 503 775-2117 ICHI TERIYAKI RESTAURANT #25 19000 HW PAC/1C HWY 1TTL. 030 T I GAUD C=, WALK-IN COOLER ANCHOR DETAILS DATE: 8/14/14 BY: KJY SCALE: N.T.S. # SK2 RECEIVED JUL 292014 CITY OF TIGARD BUILDING DIVISION -••••••., FM14127657 Vol.1 Sec.1 Page 1 Issued: 10-10-00 DESCRIPTION PRODUCT COVERED: tISL,CNL- Exhaust Floods without Exhaust Dampers Models-MI followed by SF,SB or FD followed by 42 followed tr,'any number 72 or HOOD LENGTHS: Hoods maybe 72 inebes tong or greater. Hoods 72 to.120 inches may have the exhaust duct located anywhere along the length of the hood. Exhaust hoods over 120 inches (1011)up to 216 inches(18ft)must have the exhaust duct centered on the hood. Hoods over 216 inches shall have an exhaust duct no more than 108 inches(9f)from the center of the duct to the hood edge and shall have a duct connection every 216 inches(18`11). GENERAL: • These are exhaust hood assemblies intended principally for use over restaurant-type cooking equipment such as ranges,broilers,deep fat yas,grills,etc.in combination or separately. The assemblies arc factory-built units that collect and exhaust cooking vapors. INSTALLATION' These eschaust hoods arc intended tor use in accordance with she Standard of the National Fire•Ptoteetion Association for the Installation of Equipment for the Removal of Smoke and Grease-Loden Vapors from Commercial Cooking Equipment,NFPA.No.96. • CAMS • I . • CERTIFICATE OF COMPLIANCE certificate Number 20130205-4.41-i27657 Report Reference MH27657-20001030 Issue Date 2013-FEBRUARY-05 Issued tu: MUTUAL INDUSTRIES INC ES 1605 S 93RD ST SEATTLE WA 98106 This Is to certify that EXHAUST HOODS WITHOUT EXHAUST DAMPERS representative samples at MI followed by SF,Si3 Of Fl)followed by 42 followed by.any number 72 or greater. Have.beeninvestigated by UL in accordance with the Standard(s)indicated on this Certificate. Standard(s)for Safety; UL 710, Exhaust I lords for Commercial Cooking Equipment Additional Information: See the UL Online Certifications Directory at www.ut.com/database for additional information only those Products bearing the UL testing Mark shoutd.be considered as being covered by UL's Listing and Follow-Up Service The Ill.listing Mark generally includes the following elements:the symbol UL in a circle:OD with the word•LISTEf':a contra number ber may be alphanumeric)assigned by UL and the product ct tegay name(product identifier)as vtdr_ated in the agora wiate UL Drrecwry. Look for the tit Listing Mark on the prowl .e•.ry cr... ....war.GVUerote eb..r U wa.ww....e„e .,..a1V*; r,.n.,.,way paeyn..MH&S*rrY'_l.;t...vwra+.n•ae ream.fl.t..et p.n.,pr.. PDpo.1 El i lutual industries Inc. ,\ M 1 ' Restaurant Equipment Mfg. 9832 17''Ave.SW. Sestet WA 99106 Tel: 206-767-6547 Fax. 206.767-6689 INSTALLATION and OPERATING INSTRUCTIONS MODEL#M/SF42-XX THE HANGER • a•01'M • see-••.ta J. Grr•• 4 •• 0.4 BED eft r-. .!rr s;iE.. >,avr•R eia:tET e•-!Left T� IV• x r �� Cxwar•ammo C••C 0,...11,1", 1encz 87:.nu, - ;'S•0 et S:q!:r^a•"PS.k.:04.7 V•..'KW,t••MVN Ceav CAbJ'C ..„.0".41, $ :l':'f•..�•.••••�C1.flaC•E I PRE-vyr•[ytt•-tact CoP.."iiietl M,law K+ ALI T • 11 l'� Fr X- 1 � rm.an,rr.•! ceAtiI5:111'1C! Ir.0 W I ` er r• ,ill I : s 4.411i 1 ,, L . I I) ii I it L , . Jestallation: STANDARD FEATURES I ■ • UL listed# 46 A 3 • The exhaust and supply air flow rate were • NSF Approved established under controlled laboratory Il • Conforms to NFPA Standard#96 conditions: • Slant front design - U. hated exhaust airflow rate si ` • 3"air space at rear I 400CFM'FT of capture area length. I Type 304 stainless steel where exposed with - U L listed a hood outlet shall serve not • more then a 18-foot section of hood ! • #4 finish - Greater exhaust and/or lesser supply • Factory installed duct collar air is required for complete vapor and ! • UL listed grease type baffle filters ' s-ioke removal in speciric installation. - 6' minimum overhang from open sides • Removable rease collector 9 and front side or Hood. • Pre-wired vapor-proof lights i - The exhaust and make-up air systems • Support brackets snail be connected by an electrical 1 'nteriocking switch. ighting: One 20VAC Max.12 Amos I I w r 1 .1 r - . • • •FA N-AN INFORMATION - 11 082 T ,-�� r UNIT TAG FAN UNIT MODEL I -�-I MODEL I TAD CFN ESP. RPM HP.. • VELT FLA WEIGHT (LBS.)SUNESl a !D • 2 NCA24FA _ I NCA24FA i 6000.L 2.750 864 3.00D t-1 230 I7.0 296 I7A ANA FAN INFORMATION -- Jobd 1870828 MIT MULL e I TAG FAN UNIT MD GLOVER HOUSING CFN FSP RPM H?. 0 !VOLT OLT FLA VEIGMT (LBS.7S0)ES NA l I _I.._ A3-618 618-PHI A3 6000 0300 i 444 2.300 1 ` 230 Its i 507 9,7 FAN OPTIONS FAN NI A3-GIG - SUPPLY FAN IAN I 1. UNIEMPFRED SUPPLY UNIT WITH 18' BLOWER IN SIZE *3 HOUSING UNIT 1 TAG OPTION (Qty. - Dance.) te. a INTAKE HOOD WITH EZ FILTERS I I - notarized e°ckPr_nft Dunper for Ske 3 Housing 3. SIDE DISCHARGE - AIR FLOW RIGHT -> LEFT 1 I 1 - Grease Box A. MOTORIZED BACK DRAFT DAMPER 30' X 30', STANDARD GALVANIZED CONSTRUCTION, I 1/4' REAR FLANGE, WITH H-c^DOOB/8 I t -Hew. zit (YD)- Ships Loose co r Cub Supplied by Others MOTOR, WALL SUPPLY MOUNT, FOR SIZE 3 UNTEMPERED FAN HOUSING (5193) i SORIS,S FAN EXYAUST S1,PRLY • --�_T, UNIT TAG --_ _—_ ° i MO. GREASE GRAVITY WALL SIDE GRAVITY MOTORIZED WALL CUP DAMPER MINT DISCHARGE DAMPER BAW'ER MOUNT _.__ I YES YES —2 YES _ -- J• I • I 'LEX CC',[VP Cl FIELD WIRING I i I • 41 3/8' 96 3/4' j 45 I/8' -- t 9' -I 22'---I ( I LIFTING LUG --- ---- •�• i 1 SERVICE• DISCGNVIEET I 19' - ,z--jI AI••L= SWITCH nL4�=OW �s� • 43 3/8' C CW A ACCESS S UR �L'TC(JUa 2a• AFCE.E t 17 7/8' I ` CLEAZnNCE REC. I 5 '�°" En i 1.1.11111.111111a l 17 t/r I I 3 zdt3 23 p,_7/ /,Qe • 1 1 /��j- 0 RLi-ran RI I �Um JOB# 1870828 1 DWG 0 1 DRAWN BY JMC-85 I — REV SCALE 3/8' = I'-0. 1• • • • . E 1 112 NCA24FA — EXHAUST FAN 43 311 FEATURES• - R�MINTED FAND - RESTAURANT MODEL • - UL705 AND 11762 - AKA SOUND AND AIR CERTIFIED -'SIRING ream MOTOR TO DISCONNECT SNITCH I - HIBI KAT OO( ATION 301 1 NION KAT OPEIMTXIN 7(NK t149'C>I - GREASE CLASSIFICATION TESTING 77 V2 � �i C NODAL TEI CRATURE TEST • >•S/B E76AUfi FAN AtET OPERATE CONTINUOUSLY WHILE EXHAUSTAL AIR AT 300'(C149•C) I"�"I WTI.ALL FAN PARTS NAVE READ CD THERMAL EQUILIBRIUM.MD WITHOUT ANY DETERIORATING EFFECTS TO THE FAN VHICN r ii' II 11MO<-.ASE DRAIN WOULD CAUSE WSA(F CUPERIATI[IN. 2 AINIDIAL FLARE-UP TEST CXIWAT FAN MUST OPERATE CONTINIOIBLY WHILE EXHAUSTING DEMIG GREASE VAPORS I 1 Al SOOT C316.0 FOR A PERIOD OF IS MINUTES 111T101T TIC FAN BECOMING T23 7/B- DAMAGED ANY EXTENT THAT COULD 61115E AN(NSAFE E COULD COMMON I� d UMW_ 33 I GREASE BOX L ^ /j--- 1 HINGE KIT .HD)- SHIPS LOOSE FOR CURB SUPPLIED BY OTHERS \ `\D/UCTWORK BETWEEN EXHAUST RISER OM HOOD AND FAN CBY OTHERS) � LL l V ® Ar - 1870828 A 111_5/ TS_zCd?' 43 /'o1-f/aR� ' . 1 JOB BrI•, Res l-1 I. - LQ 4T1W L ;- JOB# DRAWN BY JDC-85 T 1 ,4rte< REV. SCALE 3/8' = 1.-0'J • NOTE: 2" 11IN. AIR SPACE REQUIRED BETWEEN WALK-IN BM AND EXISTING BUILDING WALLS. WALK-IN COOLER SPEC'S: LOS ANGELES R R & FAB. LICENSE CITY OF LOS ANGELES RESEARCH REPORT: RR 25314 r * CITY OF LOS ANGELES FABRICATOR APP] D. • 2009 FEDERAL ENERGY INDEPENDENCE&�SECURITY F802055 ACT COMPLIANT 74- x-1" 2. CONSTRUCTION NSF, LOS ANGELES R R, TONGUE & GR HIGH DENSITY FOAM RAIL CAM DOWN CEI 3 1/2' WALL PANELS ► 4 _ _ - 4' CEILING PANELS C7 r cc "i FLOOR NO FLOOR ! O i i or, bz till PANEL FINISH INTERIOR CEILING: STUCCO EMBOSSED GALV: "•"3 CO 14 EXTERIOR CEIUNG: STUCCO EMBOSSED GALV. "'"'n N ,o INTERIOR WALLS: STUCCO EMBOSSED GALV . o o EXPOSED EXT. WALL: STUCCO EMBOSSED GALV... ;1' Ti: WI DOORS (I) 36' x 78" STD. CAM UFT COOLER DOOR OVERLAP DUN� cn�°SCOOLER INTERIOR OORA°D s ON STUCCO EMB, GALV. EXTERIOR DOOR AND SECTION STUCCO EMB. GALV. • d -•--- EACH DOOR 1 KASON LATCH WITH INSIDE SAFETY RELEASE #K58 `� ACCESSORIES 1 KASON CAM-RISE SPRING HINGE #1248 f I KASON CAM-RISE HINGE #1245 ' 1 KASON DOOR CLOSER #1094 z "' i i,� 1 KASON LIGHT SWITCH WITH DIGITAL #1967-2 9 _ THERMOMETER (RATED 15A, 120V AC) 2'-0' 3'-0' _2'-0'� ACCESSORIES (1) KASON VAPOR PROOF LIGHT FIXTURES CFL #1806 (SURFACE MTD.)(SHIPPED LOOSE) FLAN VIEW SILICONE//CCAUUONG & SCREWS, TRIM REFRIGERATION (1) 75HP PNTO67H8BE IN'I 0 R MED P PACKAGED RE SYSTEM UNIT 208-230 14/60HZ R-404A EC MOTORS / MOU 31 COUPON REQUIRES 6-15R NEMA RECEPTACLE -REQUIRES 25"" SINS' OPENING NC CAM DOWN CEILING—T REQUIRES 6' MIN. FOR INSTALLATION / I. Z 0 STUB-IN CONDUIT (TYP.) r•; ��� ����� d F..nILawMMmumR4alwRagWw rertntasol Jan 200i FM.F Vein a Co"nsocYl Cooing Saabn 1/4441 uY,,,��11117 M F4 540 Q.5 4k7 ?0 R.72 O 8 rt. 2*? 510 42.5 .f.7 20 P.7* U Boa N0 oft,*E.�•2►o,gone Cep Act H2 LL8C.t1n) 0 p - MTN m.NoO Cbt1 i ... A T FINISH FLOOR OREGON LABEL „_OS-z0,3 q �)R¢OOalrm� m ! i I a6 110 PATQA QTY.'DALE ID-14-2013 SHEET: J 13=4803-0817 _ IDR11Rt:NCTOR ,. :. SeN.L.3J0' ,'-0.11 OF •::. , ' ',APPROVER=NATURE CUSTOMER: '.•':i.•:1:.‘ • '+•''• .•. ,',•.'..•.':.::%':•,,:;' .I :ill., ,..7 . 'I ,,.iiiii , IE FRONT ELEVATION cusr R K Up - { COMMERCIAL COOLING • I 4:✓5�m}�i..4T;.� 4ruriJ�IF.� I'. • • PAR BNG G. INC 1.Pit31 ��� nW&/AN,11 Alt il;yLL:4r'_��Ci2ein^�� $ ai- '•7� ar,.a 2,0I Pr.a 1117 •,Aill:WrilDia: f�� C4ftI6 d U*t• 2• FAX 4,21)1/14-41777 Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 13500 SW PACIFIC HWY 30, TIGARD, OR, 97223 Commercial - Mechanical 699 Mechanical final PASS - No C of O MEC2014-00394 Jeff Grove Violation Summary: Inspector Contractor