Specifications *S �%��PZIFILq/7v CERTIFIED SOLAR SYSTEM • .1∎„/4j_y; SUPPLIER: BRAND: RADCO DRAINBACK HEAT NSy o Ague Del So EXCHANGER a ® a 602 W.22nd Street T" O� v �O Tempe,AZ 85282 USA MODEL: R-DBHX-8-80-GD-64P t, www-aguadelsol.co SYSTEM TYPE: Pumped,Indirect CERTIFICATION#: 2011101B Original Certification: August 17,2011 Expiration Date: August 17,2021 The solar system listed below has been evaluated by the Solar Rating&Certification Corporation'. (SRCC""),an ANSI accredited and EPA recognized Certification Body,in accordance with SRCC OG-300,Operating Guidelines for Certifying Solar Water Heating Systems,and has been certified by the SRCC. This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference.This document must be reproduced in its entirety. Description:Glazed Flat Plate,Differential,Immersed with Single,-50°C-58°F,Water,None,Drainback,Drainback Single-day Rating SINGLE DAY RATING CONDITIONS SI Units Inch-Pound Units Solar Energy Factor Solar Fraction System Set Temperature 57.2°C 135°F (SEFD) (SFD) Environmental Temperature 19.7°C 67.5°F 1.0 0.39 _ Ambient Temperature Profile Average 14.4°C 58°F Water Mains Temperature 14.4°C 58°F Single-day Rating Conditions: SEF0=Solar Energy Factor(info link) Delivered Load .43.3 MJ/day 41,045 Btu/day SFD=Solar Fraction(info link) Solar Irradiance 4,733 Wh/m2-day 1,500 Btulft2-day Storage Tank(s) Solar Tank Vol Solar Tank Vol Aux Tank Vol Aux Tank Vol (I) (gal) (I) (gal) 303 80 6.0 50 / Approximate Collector Area 6.0 m2,64.6 ft' The solar water system listed here has been certified by the SRCC as meeting the minimum standards for testing, installation, operation, maintenance,performance,reliability and safety as specified in SRCC Document OG-300.Thermal performance ratings are based on the • LgH� }.- successful durability and performance testing of a sample collector, ma +" where said tests have been conducted by an independent laboratory ■ approved and listed by the SRCC. The system has been modeled •■ Pr . PT using the computer simulation program TRNSYS to calculate the !♦c I ratings. �' Before the Supplier can make any change in design, materials, L� specifications,parts,or construction,the change(s)must be reported j i • to the SRCC for evaluation of continued certification. 4 N i .. Dram Back Tank Solar TOE e W r ° 5°°°" CITY OF TIGARD E��au� a wot „rota er App•oved - t, i,.itcy—[ REMARKS: C\,tlditionaHy Approved [ } Approved pians See Letter to:Follow [ Alg4t., ,,,8414 sh all be on job site. permit Number: , t _ Address:11 Z-7C B f 1,, `{'� _Ulte: 4,.° *,e, By: C'(t(r=5 9 C9AOFFICE COPY ! �� 9 Technical Director 06300 CERTIFIED X' Print Date:September,2013 Page 1 of 2 �W. X ©Solar Rating&Certification Corporation" $ r' + ;;y}� J www solar-rating.org♦400 High Point Drive,Suite 400•Cocoa,Florida 32926•(321)213-6037•Fax(321)821-0910 yJ(�;;yJC; �(,* W�..i4ry'C/(.a+,t ,4,<:,<-.,. .,a-�v .< -v ,, ,._., �:_C_•v` �,�.,,—I-,(- -/a.t,.�rvv �C. -6,„,ly+.:.`vr�<7:1..,&(`.�.L.C.'C,,,[�l,4-Y&��-M�` yV t � CERTIFIED SOLAR SYSTEM a ��''__�`Ml/io� SUPPLIER: BRAND: RADCO DRAINBACK HEAT • Agua Del Sol EXCHANGER s s 602 W.22nd Street MODEL: R-DBHX-8-80-GD-64P f Of v , Tempe,AZ 85282 USA www.aguadelsol.co SYSTEM TYPE: Pumped,Indirect ,, CERTIFICATION#: 2011101B Original Certification: August 17,2011 Expiration Date: August 17,2021 The solar system listed below has been evaluated by the Solar Rating&Certification Corporation"" (SRCC".),an ANSI accredited and EPA recognized Certification Body,in accordance with SRCC OG-300,Operating Guidelines for Certifying Solar Water Heating Systems,and has been certified by the SRCC.This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference.This document must be reproduced in its entirety. Annual Ratings in OR-ZONE1 Annual Rating using hourly weather data for the chosen city: Solar Energy Factor Solar Fraction Energy Savings SEFA=Solar Energy Factor(info link) SEA=Solar Fraction(info link) (SEFA) (SFA) (kWh) Energy Savings=Estimated annual energy saved compared to a Py 0.9 0.34 2310 conventional water heater using the same type of backup 1 Only the following options for the collector array are approved: Collector Panel Option Collector Panel Request Collector Panel Collector Panel Quantity Total Panel Total Panel Manufacturer Number Model Number Name area(m2) area(ft2) 1 ,Agua Del Sol 2011100A 408P-HP Radco 2 6.00 64.56 (Superseded) X X ,tip hh� Tr 0 I ,.\lets_`O 0G-300 CERTIFIED �, Print Date:September,2013 Page 2 of 2 W ' ©Solar Rating&Certification Corporations" 1 j yy��..'',YY,``>>��,,'y�, www.solar-rating.org•400 High Point Drive,Suite 400•Cocoa,Florida 32926•(321)213-6037•Fax(321)821-0910 s�� V - ,cam. -... : :- . -: 0: ' .Xis`X00XXX 000. .. `. .0:0:' ss ''' f �,s i I f jC44,, CERTIFIED SOLAR COLLECTOR % _, ._`Mlib_ 9 SUPPLIER: BRAND: Radco z ° Ague Del S01 MODEL: 408P-HP 602 W.22nd Street 6 Tempe,AZ 85282 USA COLLECTOR TYPE: Glazed Flat Plate ° OJ "� www.aguadelsol.co CERTIFICATION#: 10001846 m Original Certification: September 11,2013 Expiration Date: June 20,2025 The solar collector listed below has been evaluated by the Solar Rating&Certification CorporationTM (SRCCTM),an ANSI accredited and EPA recognized Certification Body,in accordance with SRCC OG-100,Operating Guidelines and Minimum Standards for Certifying Solar Collectors,and has been certified by the SRCC.This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference.This document must be reproduced in its entirety. COLLECTOR THERMAL PERFORMANCE RATING K lowatt-fours(thermal)Per Panel Per Day Thousands of Btu Per Panel Per Day Climate-> High Radiation Medium Radiation Low Radiation Climate-> High Radiation Medium Radiation Low Radiation Category (6.3 kWh/m'.day) (4.7 kWh/m'.day) (3.1 kWh/m'.day) Category (2000 Btu/82.day) (1500 Btu/ft'.day) (1000 Btu/ft'.day) (Ti-Ta) (Ti-Ta) A(-5°C) 12.4 9.5 6.5 A(-9°F) 42.4 32.3 22.3 B(5°C) 10.6 7.6 4.7 B(9°F) 36.0 26.0 15.9 C(20°C) 8.1 5.2 2.4 C(36°F) 27.6 17.8 8.3 D(50°C) 4.1 1.7 0.0 D(90°F) 13.9 5.7 0.0 E(80°C) _ 1.2 0.0 0.0 E(144°F) 4.1 0.0 0.0 A-Pool Heating(Warm Climate)B-Pool Heating(Cool Climate)C-Water Heating(Warm Climate) D-Space&Water Heating(Cool Climate)E-Commercial Hot Water&Cooling COLLECTOR SPECIFICATIONS Gross Area: 2.998 m' 32.27 ft' Dry Weight 47 kg 104 lb y:c Net Aperture Area: 2.861 m' 30.80 ft' Fluid Capacity: 9.1 liter 2.4 gal Absorber Area: 2.867 m' 30.86 ft Test Pressure: 1103 kPa 160 psi TECHNICAL INFORMATION I Tested in accordance with:ISO 9806 ISO Efficiency Equation[NOTE Based on gross area and(P)=Ti-Ta] SI UNITS: r1=0.682-5.685(P/G) Y Intercept 0.682 Slope: -5.685 W/m'.°C - . IP UNITS: q=0.682-1.002(P/G) Y Intercept 0.682 Slope: -1.002 Btu/hr.ft'.°F - Incident Angle Modifier Test Fluid: Water B 10 20 30 40 50 60 70 Test Mass Flow Rate: 0.0204 kg/(s m') I 14.75 Ib/(hr ft') Kra 1.0D 0.98 0.96 0.92 0.86 0.75 Impact Safety Rating:0 REMARKS: • d6[w1lFltA//g� jil07 CM Technical Director 0G-100 CERTIFIED 5-..).,'('cl* Print Date:September,2013 Page 1 of 3 •. ©Solar Rating&Certification CorporationTM �j2� Z www.solar-rating.org•400 High Point Drive,Suite 400•Cocoa,Florida 32926•(321)213-6037•Fax(321)821-0910 > 2 CERTIFIED SOLAR COLLECTOR • �*‘`p1/,_y9 SUPPLIER: BRAND: Radco o Ague Del Sol MODEL: 408P-HP 4 ` a 602 W.22nd Street O Tempe,AZ 85282 USA COLLECTOR TYPE: Glazed Flat Plate • www.aguadelsol.co CERTIFICATION#: 10001846 Original Certification: September 11,2013 Expiration Date: June 20,2025 The solar collector listed below has been evaluated by the Solar Rating&Certification Corporation'" (SRCCT"),an ANSI accredited and EPA recognized Certification Body,in accordance with SRCC OG-100,Operating Guidelines and Minimum Standards for Certifying Solar Collectors, and has been certified by the SRCC. This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference.This document must be reproduced in its entirety. ADDITIONAL INFORMATION(click here to return to the rating page) Test Lab: Atlas Weathering Services Group Test Report Date: . 20,2013 Test Report Number: AT32521 Test Location: outdoors SOLAR COLLECTOR CONSTRUCTION DETAILS Gross Length: I 101.57 in I Gross Width: I 45.75 in I Gross Depth: I 3.00 in COLLECTOR MATERIALS Outer Cover: • Glass sheet Enclosure back: Aluminum . Insulation: Foam,Fiber Inner Cover. None Enclosure side: Aluminum _Side Insulation: Foam,None Absorber Description: • Tubes connected to Fins Flow Pattern: Parallel/Harp Riser Tube: Copper Fin: Copper - Absorber Coating: Moderately selective Tube to fin connection Mechanical GLAZING Outer Cover Inner Cover Material: Glass sheet None Surface Characteristics: Textured Thickness: 0.140 in N/A Transmissivity: High(equal to or greater than 90%) Length: 96.06 in Width: 43.70 in Tube Glazing to Header Enclosure Seal: EPDM gasket ABSORBER: Absorber Coating: I Moderately selective Header Material: .Copper Header OD: 1.130 in Header Wall: 0.037 in Riser Tube Material: Copper Riser Tube OD: 0.504 in Riser Tube Wall 0.040 in Thickness: Fin Material: Copper Fin Thickness: 0.008 in `�`CI�iIFICAIig-Co P3 OG-100 CERTIFIED Print Date:September,2013 Page 2 of 3 'W1211W S ©Solar Rating&Certification Corporation 'Y�, www www.solar-rating.org♦400 High Point Drive,Suite 400•Cocoa,Florida 32926•(321)213-6037•Fax(321)821-0910 +�. ''yam, �C. ;1:;;<:.,c.;L...;.::„ ,_C,_ .._<1,<,..,;<..X...<.,�,c „<.,i..�., ti<,.. ,,•,,,'t,<s.. ..'-ti.Cti.'Gt.'c%..X-..«: , -C ,,t--..<-c.'�-1.''...4Z=4"®-`fit • ����\AIIFICgjjn, y;5 ■_`i//_- y Certification#: 10001846 Supplier: Agua Del Sol } a Brand Name: Radco �.� -- %' Model Number: 408P-HP 1! t Flow Pattern: Parallel/Harp . Number of Riser 12 Tube Spacing: 3.1 in Number of times 1 Tubes: each riser crosses the absorber: Length of Flow Path: 8.432 ft Riser to Fin/Plate Mechanical Bond: INSULATION: Location Type Thickness Location Type Thickness Back—Top Layer Foam 1.0 in Sides—Inner Layer. Foam 1.0 in Back—Bottom Layer. Fiber 1.2 in Sides—Outer Layer None Enclosure Fastening Methods: I Screws Power Output per Collector(W) [Ti-Ta,G=1000 W/m'] 0 10 30 50 70 2046 1875 1535 1194 853 PRESSURE DROP Flow AP Flow AP mi/s Pa gpm In H2O 20 0 0.32 0.0 50 0 0.79 0.0 80 0 1.27 0.0 .nrtA?!rrr!t„.r ® _ OG-100 CERTIFIED Print Date:September,2013 Page 3 of 3 W. ©Solar Rating&Certification Corporation"" Zy k70;, �JyyJ-CC��� ��Cy www solar-rating.org•400 High Point Drive,Suite 400•Cocoa,Florida 32926•(321)213-6037•Fax(321)821-0910 �,�'.,'-ti.<%,'-.._.,r,„<„ •.,,Iti,<-•,,:-,,t-C;,f;;::•.x,,<_0.;'(-::.<<„<-�.,Y ti."'ti,'��„,c:,„-.1,1.'t-.c.'�-C.'(7.t,'C.;�:„-_,,c-,:c-.J<-Gc-,,r%C.'c::GX)Z,-`ct '�:� . 1 r-' t: lI • . 4 DCO Solar water heating collectors Solar Water Heating Durable,high .1 performance glazing, ` Copper fins and textured to reduce glare Bronze painted and is copper waterways and tempered to resist embossed backing Provide maximum thermal tress sheet heal conductive Exclusive Radco design path for heat transfer. _ s t-ti _ provides seal and allows for ,{ ms •„ , - easy absorber removal for Multiple sizes to SerYicC. I+ • accommodate all -I insulated on back �: installation requirements .tZ 1 and sides tar maximum All copper to heal retention.Blanket conduct heat and resists high stagnation resist corrosion ��_®® temperatures. t srt.0,2, 3n Brazed assemblies Ar1 are pressure tested Bronzed anodized t: to 150 per i - - �. > frame,protects • .4 _ins 3 \ and enhances collector High performance coatings Withstands high stagnation appearance. I. with good durability Extruded aluminum with temperatures. for all applicanons. stainless steel fasteners . SPECIFICATIONS „Ai, Absorber Plate: 0.008 inch Rollformed copper sheet 'rt` • Absorber: Black Chrome selective coating over nickel plate or 00 electrostatic acrylic black paint. Plumbing: Type M Copper:1 inch or 1.5 inch internal copper manifolds with 0.5 inch O.D.waterways. l' is Manifold Seal: EPDM Insert Glazing: 0.125 inch Low iron tempered glass Glazing Seal: Extruded"U"channel Insulation: Foil faced polyisocyanate insulation board. Fiberglass j blanket that better withstands the higher operating temperatures. r� i . Frame: Extruded aluminum with stainless steel fasteners. ' Frame Finish: Bronze anodize Backing Sheet: Bronze painted and embossed 0.018 inch aluminum sheet. ENERGY STAR • Model Width Length Manifold Depth Gross Net Area Dry Weight Filled Capacity Absorber Number (Inches) Width Area (Sq.Ft.) (Lba) Weight (Gal) Coating 1 (Lbe) 1 308P 35.125 97.125 39 315 23.69 22.11 76 83 0.88 Flat Black Paint 308C 35.125 97.125 39 3.25 23.69 22.11 78 85 0.88 Black Chrome I. 408P 43.75 101.625 49 3.25 32.29 30.21 102 112 125 Flat Black Paint ii li 408C 45.75 101.625 49 3.25 32.29 30.21 105 115 125 Black Chrome ii 410P 45.75 125.625 49 3.25 39.91 37.55 125 137 1.50 Flat Black Paint 410C 45.75 125.625 49 3.25 39.91 37.55 129 141 130 Black Chrome 4I 2P 45.75 152.125 49 3.25 48.33 45.64 150 164 1.78 Flat Black Paint 412C 45.75 152.125 49 3.25 48.33 45.64 155 169 1.78 Black Chrome helOQl • . i INSTALLATION AND MOUNTING INFORMATION FIGURE 2.1 0 0 c lo 1 C[drrl■ EMI Sarno Mut Hoan NM NCI Jan NM 'N. Ltd WNW Lick Mow i &111111111" �. Mufti a $ INN &RE IM. iambi M1nww kW Sila Heim NI I NMI lair Mop Oil . I IWO*Mr wr.►wlMr J nr1rMwrr NW Wow Won 0 0 .r c ling N.. taw 411c—.L. • a•.NM Me � Wafts Hip L:Mfst; Ssollisi MMtM•,kWMid NoAmliar ---MAN Mono SW Sint 4 all mar lad liar Elm.-• r Root taw g---- i kr ----.. 0 1 Ii ` Truss mRAE N. roe Some 'Stalled b!Mir 1.20 0 6000 Series A RADCO Drainback Heat �i Solar Water Heating Systems Exchange Modules 1 INTRODUCTION , - 1 t. RADCO has developed a mechanical-control package for drainback 6,1 l systems. This drainback heat exchange module (DBHX) is a factory- . �.. assembled unit which provides a single walled heat exchanger,collector ; .• , fluid reservoir, solar collector fluid circulator pump, hot water booster circulator pump and a differential temperature controller unit, combined ''• into one attractive module. The use of this module allows any solar ii collector and any solar storage tank to be combined to form a drainback system. PRINCIPLE OF OPERATION `_ - A drainback system is just what the name implies. When inclement weather or nightfall shuts down the system,the water in the solar collector loop drains back into an indoor fluid reservoir by the force of gravity. The 1 water is returned to the collector piping whenever the system is reactivated. Heat energy is not wasted in heating the solar collector(as in recirculating systems). Cycling on partly cloudy days does not dump • energy(as in draindown systems)since the collector fluid is stored in an insulated reservoir. Drainback removes all water from the solar collector and piping whenever the solar energy collection process is not active. Freeze protection is automatic and fail-safe. t COMPONENTS Accumulator Tank: .:' B and 12 gallon capacity;14 gauge steel;constructed c# to AMSE standards; fiberglass insulated; internal d drainback orifice;filling and draining provisions. V Differential temperature controller: Solid-state; 115 VAC; plug-in line cord; UL listed; • adjustable high temperature shut-off; includes two = sensors; adjustable "on" differential and 4° off t, I •— - t differential. I( i I t• I t — Circulator Pumps: IIcoRrxouER I 8 and 12 gallon DBHX Modules use identical pumps . d pumps and are water lubricated,field repairable, low rorr �� "" power consuming,UL listed,and have a bronze body • k�' "v in potable water loop. = d DBHX MIME Heat Exchange Coil: MODULE All copper and singlewalled. • • • Specifications EDX 6002 EDX 6005 Accumulator tank pressure 50 psi max 50 psi max Accumulator tank construction... Steel,14 gauge end caps,14 gauge wallsSteel, 14 gauge end caps, 14 gauge walls Operating temperature 200°F max. 200"F max. • Tank,total fluid capacity 7.5 gallons 11.3 gallons Tank,usable fluid capacity 5.8 gallons 9.3 gallons Insulation 1"fiberglass blanket,R4 1"fiberglass blanket,R4 Weight 55 Ibs,dry 71 Ibs,dry Weight,shipping. 63 lbs 80 lbs Controller Solid-state,115 VAC Solid-state, 115 VAC Input 60 Hz,10 amps 60 Hz,10 amps Output 115 VAC,7.2 amps 115 VAC,7.2 amps Circulator pumps 115 VAC,60 Hz 115 VAC,60 Hz Single phase Single phase Absorber loop 1/20 hp,1.2 amps 1/20 hp,1.2 amps Cast iron Cast iron • Storage Loop 1/40 hp,0.68 amp 1/40 hp,0.68 amp Bronze body Bronze body Jacket ABS ABS Module Dimensions 0 a. Top view :11 ' li O N • a ,)o k , • / n O O `µ b 1 WW • 7. r Side Cut-out View b1, Manufactured by -w; INTEGRATED SOLAR, LLC t 2030 W. Pinnacle Peak Rd. 4 Phoenix, AZ 85027, USA Tel: 623-869-0561 • 800-927-2326 �. Fax: 623-669-6029 integratedsolar.com