Loading...
Plans FEB 262014 7409 ECH CENñR 7409 SW TECH CENTER ROAD TIGARD OR FIRE ALARM DATASHEETS AND CALCULATIONS OC ATED / 041° 'Pr—cr/V. Prepared by Fire Systems West, Inc. 600 SE Maritime Avenue Suite 300 Vancouver, WA 98661 (503) 289-2208 CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved plans Approved: [ Vj shall be on job site. OTC: i Pcrniil #: (1 C/ At°cir'.,;s: • „- �: . 41__.,11/ OFFICE COPY Sul • B : �i:�. Date: r 4 _ { _ ! tt t> .. G f .. "= J 09, W Tech C nter Dye igard OR 97,223 USA o . -..,,,.-. --a __I� .� .�.d,'=kR•�.,Yj�: ....- s : ..‘,"."‘'._...4.,` ,t0,11.=',:sti(:,.....t!- ' . ,,,, ! e w w, SCOPE OF WORK: Demo panel in suite 145 that is not required as well as smoke detectors that have been disconnected for years. Building has a SK5207 FACP monitoring the existing sprinkler riser with spare zones. We will add 1 smoke and 1 pull to this panel. Th SYSTEM _gam -_-11 SENSOR Photoelectric 1----1,,..4&=4: ` � Smoke Detectors , x a , ilir System Sensor's i3"series smoke detectors represent significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation ,M ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug in detector line,mounting base included plug-in design.This allows an installer to pre-wire the bases included with the heads.The large wire entry port and in-line terminals •Large wire entry port provide ample room for neatly routing the wiring inside the base. •In-line terminals with SEMS screws The base accommodates a variety of back box mounting methods, Mounts to octagonal and single gang backboxes,4-square as well as direct mounting with drywall anchors.To complete the •backboxes,or direct to ceiling installation,i3 heads plug in to the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base •Removable detector cover and chamber Intelligence.i3 detectors offer a number of intelligent features Built-in remote maintenance signaling to simplify testing and maintenance.Drift compensation and • smoothing algorithms are standard with the i3 line to minimize •Drift compensation and smoothing algorithms nuisance alarms.Two-wire i3 detectors needing cleaning can •Simplified sensitivity measurement generate a remote maintenance signal,when connected to the Wide angle,dual color LED indication 2W-MOD2 loop test/maintenance module,or to a panel equipped with the i3 protocol.This signal is indicated by LEDs located at the •Loop testing via EZ Walk feature module and the panel.The SENS-RDR,a wireless device,displays the •Built-in test switch sensitivityof P detectors in terms of percent per-foot-obscuration. Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on two-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings 411) ® (0) MEA MSFM LISTED APPROVED I 1 approved approved 5911 3011446 7272-1204210 290-01-E 2093 c e Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number hied to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel,and shall provide a loop testing capability to verify the circuit without testing each detector individually. ;Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @1 2V,23mA @ 24V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz.(178 grams) Operating Temperature Range 2W-B and 4W-B:32°F-120°F(0°C-49°C);2WT-B and 4WT-B:32°F-100°F(0°C-37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft.nominal Input Terminals 14-22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current , 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12V,23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V,23mA @ 24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 in.(16.76cm)diameter SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 cm System sense. L� SENSOR r U current rod roam,r Y a mil a ,k,K-Vy,sf:,_,,, . e t Phone:800-SENSOR2•Fax:630 377 6495 `""" product"�"""°""'a 06.7/06 s'""0 O`""'�'° " A05.0318-006.7/06�s 16/6 F a r e ri h t y Conventional Pull Station Models PS-SA and PS-DA The PS-DA and PS-SA Pull Stations are manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA is a dual-action model. The PS-SA (IL is a single-action model. Both the PS-DA and the PS-SA are ?�3 equipped with key lock/ reset. Both are designed to meet multiple i,_R061 applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate. The single-action pull-station is activated by a single pull-down of the alarm handle. The dual-action versions require pushing in the handle, then pulling the handle down for activation. The PS-DA and FIR 1 PS-SA manual pull stations are UL listed and meet the ADA requirement of a 5-lbs. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. • Molded terminal numbers can be found adjacent to the wiring • • • terminals. LULO\ N 4, Models: PS-SA— Single action with 'pigtail' connections and a key lock reset. Pigtail wires are provided for connection to the Fire Alarm Control Panel's (FACP) initiation circuit. PS-DA— Dual action model with screw terminal connections and a lock reset. SILENT PS-DASP — Same as PS-DA except with both English and Spanish ' KNIGHT operating instructions. g Features: '1r • UL Listed • CSFM Listed Specification: • Meets ADA requirements Dimensions: Height: 5-1/2"(13.97 cm) • Operating instructions are molded into the handle along with Width: 4"(10.16 cm) Braille text. Depth: 1-7/16"(3.65 cm) • Made of durable Lexan Operating • Available in Spanish temperature: 32°F to 120°F (0°C to 49°C) • Key resettable Electrical: • Easy to Install and operate Switch Contact • Single or dual action Rating: 0.25 A @ 30 VAC or VDC • Surface mount box available Accessories: SB-I/0 Surface Mount Back-box BG-TR Trim Ring SILENT 7550 Meridian Circle Maple Grove,Mn 55369-4927 P/N 350250 Rev B,10/06 KNIGHT 763-493-6455 1-800-328-0103 Copyright©2006 Silent Knight Fax:763-493-7475 http://www.farenhyt.com .=.t r , ' - t _ fi 'E IPACTIVATEDn 1 PL,Ptit,711110110jAl lir :12 ' k ( 'A El , ,,,, .- ,...... .i II SILENT i' i KNICf3T di PS-DA PS-SA Rear PS-DA Rear �. � FIRE FUEGO/FIRE FIR :`. ,.°. EMPUJEY . PUSH I� � 1 PUSff IN �. . . . : . . HALE HAc AA3AJQ j PULL 1 PULL DOWN PULL DOWN DOWN j SILENT i„, SILENT pt. SILENT KNIGHT KNIGHT 1 ) KNIGHT L o j L • ' PS-DA PS-DASP PS-SA 3''" SILENT This document is not intended to be used for installation purposes.We try to keep our Mg KNIGHT or information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 7550 Meridian Circle Suite 100, Maple imonanNiimorom by Honeywell Grove,Mn 55369-4927.Phone:(800)328-0103,Fax:(763)493-6475. Made in the U.S.A.