Report u3° 2 0) 2- 00 5 4 :r v FL „We? B+T GRP July 13, 2012 SEP 1 1 2012 Ms. Cathy Garziano ��p�;B&T Engineering, Inc. Crown Castle CI j T�anru,J1717 S. Boulder, Suite 300 5350 North 48th Street Suite 305 UILDING DIVISCO ulssa, OK 74119 Chandler,AZ 85226 V vv ii II��JJ��18) 587-4630 (480)735-6952 ctuttle @btengineering.corn Subject: Structural Analysis Report Carrier Designation: Sprint PCS Co-Locate-Interim Loading Carrier Site Number: PO54XC011 Carrier Site Name: N/A Crown Castle Designation: Crown Castle BU Number: 879602 Crown Castle Site Name: Barrows RD Crown Castle JDE Job Number: 179416 Crown Castle Work Order Number: 496950 Crown Castle Application Number: 150758 Rev. 4 Engineering Firm Designation: B&T Engineering, Inc. Project Number: 78702.001 Site Data: 16744 SW Scholls Ferry Road, Beaverton,Washington County, OR Latitude 45°25'34.61", Longitude-122°50'53.85" 100 Foot-Monopole Tower Dear Ms. Garziano, B+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 467312, in accordance with R. application 150758, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Existing + Proposed Equipment Sufficient Capacity Note:See Table 1 and Table 2 for the proposed and existing loading,respectively. The analysis has been performed in accordance with the TIA-222-G standard and the 2010 Oregon Structural Specialty Code (2009 IBC) based upon a wind speed of 95 mph 3-second gust, exposure category C with topographic category 1 and crest height of 0 feet. All equipment proposed in this report shall be installed in accordance with the attached drawings for the determined available structural capacity to be effective. We at B+T Group appreciate the opportunity of providing our continuing professional sery-:s to you and Crown Castle. If you have any questions or need further assistance on this or any other proje ease give us a call. Respectfully submitted by: r 'to p It I •iEGt7N Raul Ortiz Jr., E.I.T. Chad E. Tuttle, P E t3 �'R Project Engineer President tnxTower Report-version 6.0.4.0 July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CC!BU No. 879602 Project Number 78702.001,Application 150758, Revision 4 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2)ANALYSIS CRITERIA Table 1 -Proposed Antenna and Cable Information Table 2-Existing Antenna and Cable Information Table 3-Design Antenna and Cable Information 3)ANALYSIS PROCEDURE Table 4-Documents Provided 3.1)Analysis Method 3.2)Assumptions 4)ANALYSIS RESULTS Table 5-Section Capacity(Summary) Table 6-Tower Component Stresses vs. Capacity 4.1) Recommendations 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7)APPENDIX C Additional Calculations • tnxTower Report-version 6.0.4.0 July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CCI BU No. 879602 Project Number 78702.001,Application 150758,Revision 4 Page 3 1) INTRODUCTION This tower is a 100 ft. Monopole tower designed by Summit in April of 2001. The tower was originally designed for a wind speed of 85 mph per TINEIA-222-F. 2)ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 95 mph with no ice, 30 mph with 1.25 inch ice thickness and 60 mph under service loads, exposure category C with topographic category 1 and crest height of 0 feet. Table 1 - Proposed Antenna and Cable Information Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Note Level (ft) Elevation Antennas Manufacturer Lines Size(in) (ft) _ 3 Powerwave P65.16-XLPP-RR ' Technologies 1 I Dragonwave Horizon Compact Plus 98.0 100.0 1 , Andrew VHLP2-18 3 17/16 — Samsung ' 1 13/64 3 Telecommunications RRH-C2C w/Ext Filter Samsung 3 Telecommunications RRH-P4 Table 2-Existing Antenna and Cable Information Center .. Number Number Feed Mounting Line Antenna of Antenna Model of Feed Line Note Level (ft) Elevation Antennas Manufacturer Lines Size(in) (ft) 100.0 j 6 Ems Wireless I RR65-19-02DP 6 1 1/4 11 98.0 I- 98.0 1 — 'Platform Mount[LP 714-1] — I — 1 1 3 Ems Wireless I RR33-20-00DP 90.0 90.0 3 Ems Wireless I RR65-19-00DP 18 7/8 1 { 1 I — T-Arm Mount[TA 602-3] 4 Kathrein 840 10057 85.0 85 0 4 Clearwire Type IV BTS 5 5/16 1 82 0 1 I Radiowaves HP2-23 1 1/2 I 1 I Trimble I ACUTIME 2000 Notes: 1) Existing Equipment 2) Equipment to be Removed Table 3-Design Antenna and Cable Information Center Number Number Feed Mounting Line Antenna of Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size(in) (ft) 100 100 j 1 1 -- I 14' Low Profile Platform I 12 I EMS I RV90-17-00DP Pcs Panel 1 tnxTower Report-version 6.0.4.0 July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CCI BU No. 879602 Project Number 78702.001,Application 150758, Revision 4 Page 4 • Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size(in) 90 1 1 — 14'Low Profile Platform N 90 12 EMS RV90-17-00DP Pcs Panel 80 80 1 -- 14'Low Profile Platform 12 ( EMS RV90-17-00DP Pcs Panel 3)ANALYSIS PROCEDURE Table 4- Documents Provided Document Remarks Reference l Source Online Application Sprint Co-Location Revision#0 1 150758 CCI Sites Tower Manufacturing Drawings Summit Manufacturing ,LLC 1625431 CCI Sites Job.29201-0364 Foundation/Geotechnical Data Summit Manufacturing , LLC 1486071 CCI Sites Job.29201-0364 Antenna Configuration ( Crown CAD Package Date:06/05/2012 J CCI Sites 3.1) Analysis Method tnxTower(version 6.0.4.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) Mount areas and weights are assumed based on photographs provided. This analysis may be affected if any assumptions are not valid or have been made in error. B&T Engineering, Inc. should be notified to determine the effect on the structural integrity of the tower. 4)ANALYSIS RESULTS Table 5-Section Capacity(Summary) Section Elevation(ft)1 Component I SIB l Critical ament I P(K) 5F'(R) Capacity' Pass 1 Fail allow' L1 100-72.75 Pole TP26.088x22x0.188 1 -5.765 1023.680 39.5 Pass L2 72.75-36 Pole TP31.227x25.225x0.219 2 -9.857 1415.830 75.2 Pass L3 36-0 Pole TP36.19x30.189x0.25 3 -15.906 1886.610 90.6 Pass Summary Pole(L3) 90.6 Pass Rating is 90.8 Pass tnxTower Report-version 6.0.4.0 July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CCI BU No. 879602 Project Number 78702.001,Application 150758, Revision 4 Page 5 Table 6-Tower Component Stresses vs. Capacity-LC5 Notes Component I Elevation (ft) I %Capacity Pass 1 Fail 1 A nchor Rods j Base j 71.1 Pass 1 Base Plate Base 70.5 1 Pass 1 1 Base Foundation ( Base 40.9 1 Pass Structure Rating (max from all components)= 90.6% Notes: 1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity consumed. 2) Capacities up to 105%are considered acceptable based on analysis methods used. 4.1) Recommendations N/A tnxTower Report-version 6.0.4.0 APPENDIX A TNXTOWER OUTPUT 100.08 11 II DESIGNED APPURTENANCE LOADING TYPE ELEVATION I TYPE ELEVATION Lghting Rod(E) '102_ _ RR3320-00DP wl Mount Pipe(E) 90 (2)RR65-19-02DP wl Mount Pipe(E) 98 I RR33-20-00DP wl Mount Pipe(E) 90 / b _... ._ (2)RR6S19-02DP w/Mount Pipe(E) 98 RR6Si9-00DP w/Mount Pipe(E) '90 (2)RR6S19-02DP w/Mount Pipe(E) 98 RR65-19-00DP wl Mount Pipe(E) 90 P65-16-XLPP-RR w/Mount Pipe(P) 98 RR6S19-000P wl Mount Pips(E) 90 Q w Pipe( ) (2j6xz°r•.tnuntPpe)E) 90 S g 25 IR :2"MountPpe(E) 90°D i'3 RRH-C2C w/EXR FILER(P) e P 98 (2)6'x 2-Mount P pe(E) 90 p ( ) (2)6 P6S16 XLPP RR wl Mount Pie P 98 o n - RRH-C2C E FILTER(P) 98 m Mount[TA 602-3](E) 90 'I"' ., RRH-C2C w/EXT FILTER(P) 98 RR33-20-00DP w/Mount Pipe(E) 90 ,' __._..._ _ . ( ' RRH-P4(P) ' 8 98 840 10057 w/Mount Pipe(E) 85 I I RRH-P4(P) 99 (2)840 10057 w/Mount Pipe(E) 85 RRH-P4(P) 98 IACUTIME 2000(E) 85 Horizon Compact(P) 98 Pipe Mount[PM 601-3](E) 85 __ '1 8'0 2"Mount Pipe(Epnterim)) 98 Type IV BTS(E) 85 .1 8'02 Mount Pipe(E(Interim)) 98 Type IV BTS(E) 85 �, 8'x2'Mount Pipe(E(Intenm)) 98 !Type IV BTS(E) 85 •1 72.8* Platform Mount[LP 714-1](El 98 HP2-23(E) 85 _._ I VHLP2-18(P) 98 840 10057 w/Mount Pipe(E) 85 MATERIAL STRENGTH GRADE 1 Fy 1 Fu 1 GRADE I Fy I Fu A607-65 65 ksi 80 ksi TOWER DESIGN NOTES III 1. Tower is located in Washington County,Oregon. , 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 95 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 1.25 in ice.Ice is considered to increase n 3 m H 4 m in thickness with height. 0 r n V 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.000 ft 1 O 8. TOWER RATING:90.6% 1 It _ _J -� 360.11 VVV i I ALL REACTIONS ARE FACTORED 3 8 S S 0 AXIAL ft 22 r M 44K o $ it SHEAR\MOMENT 2 K 1 J 174 kip-ft I ii TORQUE 0 kip-ft 30 mph WIND-1.250 in ICE AXIAL 16 K SHEA I \ MOMENT 16 16 K 1252 kip-ft 0.08 g ,: TORQUE 1 kip ft . REACTIONS-95 mph WIND e 'S . s a 2 ii. g . B+T Group lob 78702.001-Barrows Rd, ORJBU#879602) j— 1717 S. Boulder, Suite 300 Project 100 Summit Monopole/App ID:150758;Rev:0 9.1 GRP Tulsa, OK 74119 Cl1Bnt: Crown Castle Drawn by:ROrtiz App'd: Phone:(918)587-4630 Cod: TIA-222-G Date:07/13/12 Scat.: NTS FAX: 918 295-0265 Path: Dwp No.E_1 TIA-222-G -95 mph/30 mph 1.250 in Ice Exposure C Maximum Values Vx Vz Mx - Mz • Global Mast Shear(K) Global Mast Moment (kip-ft) 0 5 10 15 20 0 500 1000 1500 110 19.4..���� 149.444 72`75g------�-'�-- -+'-�-�-- --' y-+-4-- - -. -- --I- -4--I--- --~-4-- -4----'+---- 72.750 • .............. C 0 ++ d W 36.000 _ _ 35.000 • • 0600 0.000 • 0 5 10 15 20 0 500 1000 1500 • B+T Group 1ob 78702.001-Barrows Rd, OR(BIM 879602) �J ' 1717 S. Boulder,Suite 300 P`°'e" 100'Summit Monopole/App ID:150758;Rev:0 .T GRP Tulsa,OK 74119 Coe°t: Crown Castle Drawn by:Rortiz A00'd: Phone:(918)587-4630 Oda' TIA-222-G Date:07/13/12 8u1r NTS FAX:(918)295-0265 Path:.... 5..12"No.E-4 TIA-222-G - Service - 60 mph Maximum Values a Deflection (in) Tilt(deg) Twist(deg) 0 5 10 15 20 0 0.5 1 1.5 0 0.05 0.1 0 100.••• ' ii TOO OM 1 1 1 1 1 I I 1 1 1 1 1 I 1 I I 1 1 1 I I 1 1 1 1 1 1 1 I I 1 1 I I 1 1 I 1 1 I 1 I I I 1 1 1 1 I 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 I 1 1 I I I I 1 1 1 1 1 1 1 1 I 1 I 1 1 I I 1 1 1 1 I I I I I 1 I 1 1 I 1 I 1 1 1 I I I I 1 1 1 1 1 1 I I 1 1 1 1 1 I I I I 1 1 1 1 1 1 1 1 1 1 1 I I I 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I 1 1 1 1 1 1 1 I 11 I I I I I 1 I 1 1 1 1 I I I I I 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I 72.75c_ I I I I I I I I I I I I I I 1 I __....._. �-- ;--�'-- - --�y---1--�'- 72.75.4 1 I I 1 1 1 1 1 1 1 1 I 1 I I I I I 1 1 1 1 I 1 1 1 1 1 I I I I I I I I I I 1 1 1 1 1 1 I 1 1 1 I I I I 1 1 1 1 I I I I 1 1 I I I I 1 I I 1 I t I 1 1 I I I I 11 I I I I 1 1 1 1 1 1 1 1 1 I I I I I 1 I 1 1 1 I 1 1 I I I I I I I I I 1 , I I 1 I I I I I I I I I I I � I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I 1 I I I I I I I I I I I I I I. CI3 I I I I I I I I 11 I I I I I I I I I I I I I I I I I I 0 / ' MI /'', I I I I I I I I I I I I I I I I■ 1 1 I I I I I I I I I I I I I I I I 1 I V . 1 1 I I I I I I I I I I I I I I I I I I I 1 I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 1 I I I I I I I I 38,00(L _ 38.000 1 1 1 r I l T I 1 1 i 1 I 1 I I - I I I I I I I 1 I 1 1 1 1 I 1 I I I I I I I I I 11 I 1 I I I I I I I I I I I 1 I 1 1 I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I 1 1 1 I I I I i 1 I 1 1 1 1 1 1 1 1 I I I I I 1 I 11 1 I 1 I 1 1 1 I I I I I I I I I I I I I I I I I I I 1 I 1 1 1 1 I l I I I I I I I I I I I I 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I 1 1 I I I I I I I I I 1 1 1 1 I 1 1 1 I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I 1 1 I I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0,!!! , 1 1 1 I 1 I 1 1 I I I I 1 I I I I I I 1 I D 000 a 0 5 10 15 20 0 0.5 1 1.5 0 0.05 0.1 i �- B+T Group 1ob 78702.001-Barrows Rd,OR(BU#879602) 1717 S. Boulder, Suite 300 Pmt 100'SummltMonopole/App ID:150758;Rev:0 Owl'Gf1G' Tulsa,OK 74119 Client: Crown Castle Drawn b7 Rortiz ' '°: Phone:(918)587-4630 Code: TIA-222-G Date.07/13/12 Scat' NTS FAX:(918)295-0265 Path.... D"'9 No E-5 Feedline Distribution Chart 0' - 100' p.It App Dint Fare Truss Leg Face A Face B Face C y 7.:nno icy poV 98 uri: 98.000 ! 90.000 90.000 85.000 85.000 1 I 72.750 72.750 • E a m d # it tz gi w' o ♦ A W L izi o 38.000 < 38.000 __0000 i . 0.000 0000 • B+T Group Job:78702.001-Barrows Rd,OR(BM 879602) J 1717 S. Boulder, Suite 300 Project:100'Summit Monopole/App ID:150758;Rev:0 BT GRP Tulsa, OK 74119 Client: Crown Castle Drawn by:Rortiz App'd Phone:(918)587-4630 Cede' TIA-222-G Dw:07/13/12 stele NTS FAX.(918)295-0265 Path:,.., ..,_. ...�..�.0,�..4.�...,�.,,—„,,,,m,,--___ p"y No E-7 Job Page tnxTower 78702.001 - Barrows Rd, OR(BU#879602) 1 of 10 B+T Group Project Date 1717 S.Boulder.Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtIZ Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Washington County,Oregon. Basic wind speed of 95 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.000 ft. Nominal ice thickness of 1.250 in. Ice thickness is considered to increase with height. Ice density of 56.000 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50.000°F. Deflections calculated using a wind speed of 60 mph. A non-linear(P-delta)analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feedline supports,and appurtenance mounts are not considered. Options. Consider Moments-Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder Consider Moments-Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules Consider Moments-Diagonals V Assume Rigid Index Plate Calculate Redundant Bracing Forces Use Moment Magnification I Use Clear Spans For Wind Area Ignore Redundant Members in FEA Use Code Stress Ratios Use Clear Spans For KL/r SR Leg Bolts Resist Compression V Use Code Safety Factors-Guys Retension Guys To Initial Tension All Leg Panels Have Same Allowable Escalate Ice 4 Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz 4 Use Azimuth Dish Coefficients 'I Consider Feedline Torque Use Special Wind Profile \I Project Wind Area of Appurt. Include Angle Block Shear Check Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles Leg Bolts Are At Top Of Section SR Members Have Cut Ends -4 Include Shear-Torsion Interaction Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets Add IBC.6D+W Combination Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in L 1 100.000-72.750 27.250 3.250 18 22.000 26.088 0.188 0.750 A607-65 (65 ksi) L2 72.750-36.000 40.000 4.000 18 25.225 31.227 0.219 0.875 A607-65 (65 ksi) L3 36.000-0.000 40.000 18 30.189 36.190 0.250 1.000 A607-65 (65 ksi) Job Page tnYTower 78702.001 - Barrows Rd, OR (BU#879602) 2 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX (918)295-0265 ROrtIZ Tapered Pole Properties Section TO Dia. Area 1 r C I/C J It/� w wit in in' in' in in in" in4 in in L1 22.339 12.981 780.301 7.743 11.176 69.819 1561.628 6.492 3.542 18.891 26.490 15.414 1306.382 9.195 13.253 98.575 2614.482 7.708 4.261 22.728 L2 26.110 17.366 1372.011 8.877 12.815 107.067 2745.828 8.685 4.055 18.531 31.709 21.534 2615.901 11.008 15.863 164.903 5235.245 10.769 5.111 23.359 L3 31.264 23.757 2690.338 10.628 15.336 175.425 5384.216 11.881 4.873 19.493 36.748 28.518 4653.917 12.759 18.385 253.143 9313.957 14.262 5.929 23.718 Tower Gusset Gusset Gusset Grade Adjust.Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Diagonals Horizontals ft ft' in in in LI 1 1 1 100.000-72.75 0 L2 1 1 1 72.750-36.000 L3 1 1 36.000-0.000 Feed Line/Linear Appurtenances - Entered As Round Or Flat v Description Sector Component Placement fatal Number Start/End Width or Perimeter Weight Type Number Per Row Position Diameter it in in klf •1• 2"Rigid Conduit C Surface Ar 85.000-5.000 2 2 0.000 2.000 0.003 (E) (CaAa) 0.000 s/s Safety Line 3/8 C Surface Ar 100.000-0.000 1 1 0.000 0.375 0.000 (E) (CaAa) 0.000 sn Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg ft ft/ft klf LDF6-50A(I-1/4") A No Inside Pole 98.000-5.000 6 No Ice 0.000 0.001 (TBR) 1/2"Ice 0.000 0.001 1"Ice 0.000 0.001 2"Ice 0.000 0.001 TYPE 2(1-7/16) A No Inside Pole 98.000-5.000 3 No Ice 0.000 0.001 (P) 1/2"Ice 0.000 0.001 I"Ice 0.000 0.001 • 2"Ice 0.000 0.001 CATEGORY Se(1 A No Inside Pole 98.000-5.000 I No Ice 0.000 0.000 WIRE) 1/2"Ice 0.000 0.000 (P) I"Ice 0.000 0.000 • 2"Ice 0.000 0 000 5/. LDF5-50A(7/8") C No Inside Pole 90.000-5.000 18 No Ice 0.000 0.000 Job ob Page 78702.001 - Barrows Rd, OR (BU#879602) 3 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100'Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 R0 LIZ L Description Face Allow Component Placement Total C4A.4 Weight or Shield Type Number Leg ft ft2/.11 klf (E) 1/2"Ice 0.000 0.000 I"Ice 0.000 0.000 2"Ice 0.000 0.000 LDF4-50A(1/2") C No Inside Pole 85.000-5.000 I No Ice 0.000 0.000 (E(Inside Conduit)) 1/2"Ice 0.000 0.000 I"Ice 0.000 0.000 2"Ice 0.000 0.000 ATCB-B01-001(5/16") C No Inside Pole 85.000-5.000 5 No Ice 0.000 0.000 (E(Inside Conduit)) 1/2"Ice 0.000 0.000 I"Ice 0.000 0.000 2"Ice 0.000 0.000 •1s Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR 1 C.4A.4 C4A,1 !s,,;l Section Elevation In Face Out Face ft ft- rr ft` ft2 K LI 100.000-72.750 A 0.000 0.000 0.000 0.000 0.151 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 5.922 0.000 0.183 . L2 72.750-36.000 A 0.000 0.000 0.000 0.000 0.219 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 16.078 0.000 0.451 L3 36.000-0.000 A 0.000 0.000 0.000 0.000 0.185 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 13.750 0.000 0.382 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice A, AF C4A.4 C4AA Weight Section Elevation or Thickness In Face Out Face ft Leg in ft2 ft'' ft= ft2 K L I 100.000-72.750 A 2.751 0.000 0.000 0.000 0.000 0.151 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 30.567 0.000 0.722 L2 72.750-36.000 A 2.627 0.000 0.000 0.000 0.000 0.219 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 65.252 0.000 1.594 L3 36.000-0.000 A 2.354 0.000 0.000 0.000 0.000 0.185 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 56.120 0.000 1.326 Feed Line Center of Pressure . Section Elevation C!', CPz CPX CP, Ice Ice ft in in in in LI 100.000-72.750 0.000 0.322 0.000 0.894 - L2 72.750-36.000 0.000 0.583 0.000 1.190 L3 36.000-0.000 0.000 0.520 0.000 1.204 Pa ge tnxTower Jib 78702.001 - Barrows Rd, OR (BU#879602) 4 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 • Tulsa.OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtiz b Shielding Factor Ka Tower Feed Line 1 Description Feed Line K„ K„ Section Record No. Segment Elev. No Ice Ice Ll 7 2"Rigid Conduit 72.75-85.00 1.0000 1.0000 L 12 Safety Line 3/8 72.75-100.00 1.0000 1.0000 L2 7 2"Rigid Conduit 36.00-72.75 1.0000 1.0000 L2 12_ Safety Line 3/8 36.00-72.75 1.0000 1.0000 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement C.O., CAA. Weight or Type Horz Adjustment Front Side Leg Lateral Vert �, ft ° ft jt .t t r K ft ft Lighting Rod C None 0.000 102.000 No Ice 0.375 0.375 0.030 (E) 1/2"Ice 0.890 0.890 0.034 1"Ice 1.356 1.356 0.041 2"Ice 1.993 1.993 0.066 s/s ■. (2)RR65-19-02DP w/Mount C From Leg 4.000 0.000 98.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 (E) 2.000 l"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 (2)RR65-I9-02DP w/Mount B From Leg 4.000 0.000 98.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 (E) 2.000 1"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 (2)RR65-19-02DP w/Mount A From Leg 4.000 0.000 98.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 (E) 2.000 1"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 P65-16-XLPP-RR w/Mount C From Leg 4.000 0.000 98.000 No Ice 8.637 6.362 0.075 Pipe 0.000 1/2"Ice 9.290 7.538 0.137 (P) 2.000 1"Ice 9.910 8.427 0.212 2"Ice 11.176 10.239 0.389 P65-16-XLPP-RR w/Mount B From Leg 4.000 0.000 98.000 No Ice 8.637 6.362 0.075 Pipe 0.000 1/2"Ice 9.290 7.538 0.137 (P) 2.000 1"Ice 9.910 8.427 0.212 2"Ice 11.176 10.239 0.389 P65-16-XLPP-RR w/Mount A From Leg 4.000 0.000 98.000 No Ice 8.637 6.362 0.075 Pipe 0.000 1/2"Ice 9.290 7.538 0.137 (P) 2.000 I"Ice 9.910 8.427 0.212 2"Ice 11.176 10.239 0.389 RRH-C2C w/EXT FILTER C From Leg 4.000 0.000 98.000 No Ice 3.087 5.542 0.052 (P) 0.000 1/2"Ice 3.346 5.859 0.090 2.000 I"Ice 3.613 6.185 0.132 2"Ice 4.174 6.864 0.230 RRH-C2C w/EXT FILTER B From Leg 4.000 0.000 98.000 No Ice 3.087 5.542 0.052 (P) 0.000 1/2"Ice 3.346 5.859 0.090 • 2.000 1"Ice 3.613 6.185 0.132 2"Ice 4.174 6.864 0.230 RRH-C2C w/EXT FILTER A From Leg 4.000 0.000 98.000 No Ice 3.087 5.542 0.052 (P) 0.000 1/2"Ice 3.346 5.859 0.090 2.000 1"Ice 3.613 6.185 0.132 2"Ice 4.174 6.864 0.230 RRH-P4 C From Leg 4.000 0.000 98.000 No Ice 3.191 2.075 0.060 Pa ge tna�Tower Job 78702.001 - Barrows Rd, OR (BU#879602) 5 of 10 B+T Group Project Date 17175.Boulder,Suite300 100'Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 • Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtlz Description Face Offset Offsets: Azimuth Placement CAA, C4A.4 Weight or Type Hon Adjustment Front Side Leg Lateral Vert p f1 ft2 ft' K ft ft (P) 0.000 1/2"Ice 3.439 2.292 0.083 2.000 1"Ice 3.696 2.517 0.109 2"Ice 4.235 2.994 0.172 RRH-P4 B From Leg 4.000 0.000 98.000 No Ice 3.191 2.075 0.060 (P) 0.000 1/2"Ice 3.439 2.292 0.083 2.000 1"Ice 3.696 2.517 0.109 2"Ice 4.235 2.994 0.172 RRH-P4 A From Leg 4.000 0.000 98.000 No Ice 3.191 2.075 0.060 (P) 0.000 1/2"Ice 3.439 2.292 0.083 2.000 1"Ice 3.696 2.517 0.109 2"Ice 4.235 2.994 0.172 Horizon Compact C From Leg 4.000 0.000 98.000 No Ice 0.841 0.429 0.012 (P) 0.000 1/2"Ice 0.966 0.525 0.018 2.000 1"Ice 1.099 0.629 0.026 2"Ice 1.392 0.863 0.048 6'x 2"Mount Pipe C From Leg 4.000 0.000 98.000 No Ice 1.425 1.425 0.022 (E(Interim)) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 6'x 2"Mount Pipe B From Leg 4.000 0.000 98.000 No Ice 1.425 1.425 0.022 (E(Interim)) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 6'x 2"Mount Pipe A From Leg 4.000 0.000 98.000 No Ice 1.425 1.425 0.022 (E(Interim)) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 Platform Mount[LP 714-1] C None 0.000 98.000 No Ice 37.470 37.470 1.600 (E) 1/2"Ice 44.230 44.230 2.040 1"Ice 50.990 50.990 2.480 2"Ice 64.510 64.510 3.360 y. RR33-20-00DP w/Mount C From Leg 4.000 0.000 90.000 No Ice 7.238 5.661 0.044 Pipe 0.000 1/2"Ice 7.792 6.545 0.100 (E) 0.000 1"Ice 8.333 7.306 0.166 2"Ice 9.446 8.949 0.322 RR33-20-00DP w/Mount B From Leg 4.000 0.000 90.000 No Ice 7.238 5.661 0.044 Pipe 0.000 1/2"Ice 7.792 6.545 0.100 (E) 0.000 1"Ice 8.333 7.306 0.166 2"Ice 9.446 8.949 0.322 RR33-20-OODP w/Mount A From Leg 4.000 0.000 90.000 No Ice 7.238 5.661 0.044 Pipe 0.000 1/2"Ice 7.792 6.545 0.100 (E) 0.000 1"Ice 8.333 7.306 0.166 2"Ice 9.446 8.949 0.322 RR65-19-00DP w/Mount C From Leg 4.000 0.000 90.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 (E) 0.000 1"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 RR65-19-00DP w/Mount B From Leg 4.000 0.000 90.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 ` (E) 0.000 1"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 RR65-19-00DP w/Mount A From Leg 4.000 0.000 90.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 ' (E) 0.000 1"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 (2)6'x 2"Mount Pipe C From Leg 4.000 0.000 90.000 No Ice 1.425 1.425 0.022 Job Page m xTower 78702.001 - Barrows Rd, OR (BU#879602) 6 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 • Tulsa,OK 74119 Client Phone:(918)S87-4630 Designed by FAX.(918)295-0265 Crown Castle RortiZ Description Face Offset Offsets: Azimuth Placement CAAA CAA,. Weight or Type Hon Adjustment Front Side Leg Lateral Vert ft ft ft' fig K p ft (E) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 (2)6'x 2"Mount Pipe B From Leg 4.000 0.000 90.000 No Ice 1.425 1.425 0.022 (E) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 (2)6'x 2"Mount Pipe A From Leg 4.000 0.000 90.000 No Ice 1.425 1.425 0.022 (E) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 T-Arm Mount[TA 602-3] C None 0.000 90.000 No Ice 11.590 11.590 0.774 (E) 1/2"Ice 15.440 15.440 0.990 1"Ice 19.290 19.290 1.206 2"Ice 26.990 26.990 1.639 */* 840 10057 w/Mount Pipe C From Leg 1.500 0.000 85.000 No Ice 2.718 2.351 0.026 (E) 0.000 1/2"Ice 3.095 2.883 0.051 0.000 1"Ice 3.483 3.431 0.083 2"Ice 4.290 4.578 0.163 840 10057 w/Mount Pipe B From Leg 1,500 0.000 85.000 No Ice 2.718 2.351 0.026 (E) 0.000 1/2"Ice 3.095 2.883 0.051 0.000 1"Ice 3.483 3.431 0.083 2"Ice 4.290 4.578 0.163 v (2)840 10057 w/Mount Pipe A From Leg 1.500 0.000 85.000 No Ice 2.718 2.351 0.026 (E) 0.000 1/2"Ice 3.095 2.883 0.051 0.000 1"Ice 3.483 3.431 0.083 2"Ice 4.290 4.578 0.163 ACUTIME 2000 C From Leg 1.500 0.000 85.000 No Ice 0.297 0.297 0.001 (E) 0.000 1/2"Ice 0.374 0.374 0.005 -3.000 1"Ice 0.459 0.459 0.010 2"Ice 0.655 0.655 0.025 Pipe Mount[PM 601-3] A From Leg 1.500 0.000 85.000 No Ice 4.390 4.390 0.195 (E) 0.000 1/2"Ice 5.480 5.480 0.237 0.000 1"Ice 6.570 6.570 0.280 2"Ice 8.750 8.750 0.365 */s Type IV BTS C From Leg 1.500 0.000 85.000 No Ice 3.033 2.275 0.045 (E) 0.000 1/2"Ice 3.284 2.506 0.068 0.000 1"Ice 3.543 2.746 0.094 2"Ice 4.088 3.252 0.156 Type IV BTS B From Leg 1.500 0.000 85.000 No Ice 3.033 2.275 0.045 (E) 0.000 1/2"Ice 3.284 2.506 0.068 0.000 1"Ice 3.543 2.746 0.094 2"Ice 4.088 3.252 0.156 Type IV BTS A From Leg 1.500 0.000 85.000 No Ice 3.033 2.275 0.045 (E) 0.000 1/2"Ice 3.284 2.506 0.068 0.000 I"Ice 3.543 2.746 0.094 2"Ice 4.088 3.252 0.156 tnxTower Job Page 78702.001 - Barrows Rd, OR(BU#879602) 7 of 10 B+T Group Project Date 17175.Boulder,Suite 300 100'Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtIZ • Dishes Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight or Type Type Horz Adjustment Beam Diameter Area Leg Lateral Width Vert ft ft ft Jr' K HP2-23 A Paraboloid From 2.000 -90.000 85.000 2.042 No Ice 3.274 0.027 (E) w/Shroud(HP) Leg 0.000 1/2"Ice 3.547 0.045 -3.000 1"Ice 3.819 0.063 2"Ice 4.365 0.100 s1s VHLP2-I8 C Paraboloid w/o From 2.000 0.000 98.000 2.175 No Ice 3.715 0.031 (P) Radome Leg 0.000 1/2"Ice 4.006 0.052 2.000 1"Ice 4.296 0.072 2"Ice 4.876 0.113 Load Combinations Comb. Description No. I Dead Only 2 1.2 Dead+l.6 Wind 0 deg-No Ice 3 0.9 Dead+l.6 Wind 0 deg-No Ice 4 1.2 Dead+1.6 Wind 30 deg-No Ice 5 0.9 Dead+l.6 Wind 30 deg-No Ice 6 1.2 Dead+l.6 Wind 60 deg-No Ice 7 0.9 Dead+l.6 Wind 60 deg-No Ice 8 1.2 Dead+l.6 Wind 90 deg-No Ice 9 0.9 Dead+1.6 Wind 90 deg-No Ice 10 1.2 Dead+1.6 Wind 120 deg-No Ice 11 0.9 Dead+1.6 Wind 120 deg-No Ice 12 1.2 Dead+1.6 Wind 150 deg-No Ice 13 0.9 Dead+1.6 Wind 150 deg-No Ice 14 1.2 Dead+1.6 Wind 180 deg-No Ice 15 0.9 Dead+1.6 Wind 180 deg-No Ice 16 1.2 Dead+1.6 Wind 210 deg-No Ice 17 0.9 Dead+1.6 Wind 210 deg-No Ice 18 1.2 Dead+1.6 Wind 240 deg-No Ice 19 0.9 Dead+I.6 Wind 240 deg-No Ice 20 1.2 Dead+I.6 Wind 270 deg-No Ice 21 0.9 Dead+I.6 Wind 270 deg-No Ice 22 1.2 Dead+I.6 Wind 300 deg-No Ice 23 0.9 Dead+I.6 Wind 300 deg-No Ice 24 1.2 Dead+1.6 Wind 330 deg-No Ice 25 0.9 Dead+l.6 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+l.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+I.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+I.0 Ice+I.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+I.O Ice+I.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+I.0 Ice+1.0 Temp 31 1.2 Dead+I.0 Wind 120 deg+I.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+I.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+I.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+I.0 Ice+1.0 Temp 35 1.2 Dead+l.0 Wind 240 deg+1.0 lce+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg-Service Job°b Page 78702.001 -Barrows Rd, OR(BU#879602) 8 of 10 B+T Group Project Date 1717 S.Boulder.Suite 300 100'Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX. (918)295-0265 ROfLIZ Comb. Description No. 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg-Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 deg-Service Maximum Member Forces Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. K lap ft lap ft LI 100-72.75 Pole Max Tension 1 0.000 0.000 0.000 Max.Compression 26 -24.017 0.893 1.155 Max.Mx 8 -5.772 -206.527 4.387 Max.My 2 -5.795 -5.870 205.189 Max.Vy 8 11.302 -206.527 4.387 . Max.Vx 2 -11.150 -5.870 205.189 Max.Torque 8 1.209 L2 72.75-36 Pole Max Tension 1 0.000 0.000 0.000 Max.Compression 26 -32.821 0.980 -0.551 . Max.Mx 8 -9.861 -656.965 10.008 Max.My 2 -9.876 -14.553 649.807 Max.Vy 8 13.671 -656.965 10.008 Max.Vx 2 -13.518 -14.553 649.807 Max.Torque 8 1.208 L3 36-0 Pole Max Tension 1 0.000 0.000 0.000 Max.Compression 26 -43.844 0.979 -2.422 Max.Mx 8 -15.906 -1248.314 16.024 Max.My 2 -15.907 -23.978 1234.754 Max.Vy 8 15.765 -1248.314 16.024 Max.Vx 2 -15.617 -23.978 1234.754 Max.Torque 8 1.203 Maximum Tower Deflections - Service Wind Section Elevation Hon. Gov. Tilt Twist No. Deflection Load ft in Comb. ° ° LI 100-72.75 15.644 41 1.242 0.003 L2 76-36 9.601 41 1.118 0.002 L3 40-0 2.796 41 0.631 0.001 Job Page tnxTower 78702.001 -Barrows Rd, OR(BU#879602) 9 of 10 B+T Group Project Date _ 1717 S.Boulder,Suite 300 100'Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtIZ ■ Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 102.000 Lighting Rod 41 15.644 1.242 0.003 31025 100.000 VHLP2-18 41 15.644 1.242 0.003 31025 98.000 (2)RR65-19-02DP w/Mount Pipe 41 15.126 1.235 0.003 31025 90.000 RR33-20-00DP w/Mount Pipe 41 13.065 1.204 0.003 15512 85.000 840 10057 w/Mount Pipe 41 11.800 1.180 0.003 10341 82.000 HP2-23 41 11.054 1.162 0.003 8617 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° 0 LI 100-72.75 70.380 6 5.597 0.015 L2 76-36 43.221 6 5.036 0.011 L3 40-0 12.595 6 2.843 0.004 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ft 102.000 Lighting Rod 6 70.380 5.597 0.015 7047 100.000 VHLP2-18 6 70.380 5.597 0.015 7047 98.000 (2)RR65-19-02DP w/Mount Pipe 6 68.051 5.565 0.015 7047 90.000 RR33-20-00DP w/Mount Pipe 6 58.790 5.426 0.014 3522 85.000 840 10057 w/Mount Pipe 6 53.103 5.316 0.014 2347 82.000 HP2-23 6 49.750 5.236 0.013 1955 Compression Checks Pole Design Data Section Elevation Size L L. Kl/r A P. OP„ Ratio No. P. ft ft ft in K K +P. LI 100-72.75(1) TP26.088x22x0.188 27.250 0.000 0.0 15.124 -5.765 1023.680 0.006 L2 72.75-36(2) TP3I.227x25.225x0.219 40.000 0.000 0.0 21.118 -9.857 1415.830 0.007 L3 36-0(3) TP36.19x30.189x0.25 40.000 0.000 0.0 28.518 -15.906 1886.610 0.008 tnxTower Job Page 78702.001 - Barrows Rd, OR (BU#879602) 10 of 10 B+T Group Project Date 1717 S.Boulder.Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:29:37 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX. (918)295-0265 ROrtIZ Pole Bending Design Data Section Elevation Size M. $Max Ratio M, $Ma„ Ratio No. M M ft kip-ft hip-ft fM kip ft kip ft 4M LI 100-72.75(1) TP26.088x22x0.188 207.893 535.202 0.388 0.000 535.202 0.000 L2 72.75-36(2) TP31.227x25.225x0.219 659.465 885.883 0.744 0.000 885.883 0.000 L3 36-0(3) TP36.19x30.189x0.25 1252.033 1395.533 0.897 0.000 1395.533 0.000 Pole Shear Design Data I Section Elevation Size Actual 4V. Ratio Actual 47'. Ratio No. V. V. T T ft K K •v kip-fl kipft lg. LI 100-72.75(1) TP26.088x22x0.188 11.338 511.839 0.022 1.113 1071.717 0.001 L2 72.75-36(2) TP31.227x25.225x0.219 13.707 707.914 0.019 1.108 1773.933 0.001 L3 36-0(3) TP36.19x30.189x0.25 15.799 943.303 0.017 1.105 2794.483 0.000 . Pole Interaction Design Data .,„,ra 1 m Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria \" P. Mau M V. T„ Stress Stress _ ft 4P„ 4M 4M„. 4V 4T Ratio Ratio L I 100-72.75(1) 0.006 0.388 0.000 0.022 0.001 0.395 1.000 4.8.2 V L2 72.75-36(2) 0.007 0.744 0.000 0.019 0.001 0.752 1.000 4.8.2 V✓ l 13 36-0(3) 0.008 0.897 0.000 0.017 0.000 0.906 1.000 4.8.2 y Section Capacity Table I Section Elevation Component Size Critical P ePamb,V % Pass No. ft Type Element K K Capacity Fail LI 100-72.75 Pole TP26.088x22x0.188 1 -5.765 1023.680 39.5 Pass L2 72.75-36 Pole TP31.227x25.225x0.219 2 -9.857 1415.830 75.2 Pass L3 36-0 Pole TP36.19x30.189x0.25 3 -15.906 1886.610 90.6 Pass Summary Pole(L3) 90.6 Pass RATING= 90.6 Pass Program Version 6.0.4.0-1/27/2012 File:78702_00l_Barrows RdOR_Interim Loading.eri APPENDIX B BASE LEVEL DRAWING . r - i - - �� / \ / ,- _ -�� \ / / \ \ PROPOSED) / \•1 13/64 TO 98 FT LEVEL 3� 1-7/16" TO 98 FT LEVEL (._ \ \ 6) INSTALLED) TO 98 FT LEVEL 0¢ \ \ Q q� NOT INSTALLED) • I I Q? I I NST 1/2" TO 85 FT LEVEL 1 \ / / 1 1/2".TO 85 FT LEVEL e / 5) 5/16 TO 85 FT LEVEL \\ \\ / // \ \ -,. i/ / N. - / V f 8)7/8D)TO 90 FT LEVEL _ r . BUSINESS UNIT: 879602 TOWER ID: C_BASELEVEL APPENDIX C ADDITIONAL CALCULATIONS Square, Stiffened / Unstiffened Base Plate, Any Rod Material - Rev. F /G Assumptions: 1)Rod groups at corners. Total#rods divisible by 4. Maximum total#of rods=48(12 per Corner). 2)Rod Spacing=Straight Center-to-Center distance between any(2)adjacent rods(same corner) 3)Clear space between bottom of leveling nut and top of concrete not exceeding(1)*(Rod Diameter) Site Data Base Reactions BU#: 879602 TIA Revision: G Site Name: Barrows Rd, OR Factored Moment,Mu:, 1252 ft-kips App#: 150758;Rev:0 Factored Axial, Pu:, 16 kips Anchor Rod Data Factored Shear,Vu:_ 16 kips Eta Factor, n 0.5 TIA G(Fig.4-4) Qty: 8 Diam: 2.25 in Anchor Rod Results Rod Material: A615-J TIA G--> Max Rod (Cu+Vu/n): 184.9 Kips Yield, Fy: 75 ksi Axial Design Strength, P*Fu*Anet: 260.0 Kips Strength, Fu: 100 ksi Anchor Rod Stress Ratio: 71.1% Bolt Circle: 42 in Anchor Spacing: 6 in • Plate Data_ Base Plate Results Flexural Check PL Ref. Data W=Side: 41 in Base Plate Stress: 34.9 ksi Yield Line(in): Thick: 2.25 in PL Design Bending Strength, cD*Fy: 49.5 ksi 21.79 Grade: 55 ksi Base Plate Stress Ratio: 70.5% Max PL Length: Clip Distance: 6 in _ 21.79 N/A- Unstiffened Stiffener Data(Welding at both sides) Stiffener Results Configuration:,Unstiffened Horizontal Weld : N/A Weld Type: ** Vertical Weld: N/A Groove Depth: in** Plate Flex+Shear,fb/Fb+(fv/Fv)^2: N/A Groove Angle: degrees Plate Tension+Shear,ft/Ft+(fv/Fv)^2: N/A - Fillet H.Weld: <--Disregard Plate Comp. (AISC Bracket): N/A Fillet V. Weld: • in Pole Results Width: in Pole Punching Shear Check: N/A - Height: in Mae PL Length Thick: in Yield Line Notch: in Anchors at corner- t- BASE PL Grade: ksi oty/4 MR THICKNESS Weld str.:_ _ksi �/� 0 rt Anchor, Typ. STIFFENED CONFIGURATION ASSUMED IN TOOL Pole Data o� gt , B.G. Diam: 36.19 in ! , Thick: 0.25 in "put dear space Grade: 65 ksi at B.C. tar Single Anchor Case #of Sides: 18 "0"IF Round nmr Pole w/ `� DIAM = D yy■■ Anchor Spacing Some As Stiffener Spacing, 1 �' Except for iple Corner Anchor (Input Clear Space) **Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CCIplate 1.5-Square Base F-G 1.2, Effective March 19,2012 Analysis date: 7/13/2012 • r • • • • CAISSON Version 10.35 2:41:50 PM Friday, July 13, 2012 B&T Engineering ************************************************************************************************** * * CAISSON - Pier Foundations Analysis and Design - Copyright Power Line Systems, Inc. 1993-2010 * * * ************************************************************************************************** Project Title: 78702.001 - Barrows Rd, OR (BU# 879602) Project Notes: 100' Summit Monopole- 6' Dia, 21' Minimum Depth(20.5' Bearing) Calculation Method: Full 8CD ******* I N P U T D A T A Pier Properties Diameter Distance Concrete Steel of Top of Pier Strength Yield above Ground Strength (ft) (ft) (ksi) (ksi) 6.00 0.50 Soil Properties Layer Type Thickness Depth at Top Density CU KP PHI of Layer (ft) (ft) (lbs/ft^3) (psf) (deg) 1 Sand 5.00 0.00 100.0 1.000 2 Sand 3.00 5.00 100.0 3.000 30.00 3 Sand 10.00 8.00 100.0 3.500 33.75 4 Sand 10.00 18.00 100.0 4.000 36.87 Design (Factored) Loads at Top of Pier Moment Axial Shear Additional Safety Load Load Factor Against Soil Failure (ft-k) (kips) (kips) 1252.0 16.0 16.00 ? 1.333 (F.S.) , Soil Interaction = (1.333/3.10)x 100% = 43.0% • • ******* R E S U L T S Calculated Pier Properties Length Weight End Bearing Pressure (ft) (kips) (psf) 21.000 89.064 565.9 Ultimate Resisting Forces Along Pier Type Distance of Top of Layer Thickness Density CU KP Force Arm to Top of Pier (ft) (ft) (lbs/ft^3) (psf) (kips) (ft) Sand 0.50 5.00 100.0 1.000 22.50 3.83 Sand 5.50 3.00 100.0 3.000 105.30 7.12 Sand 8.50 7.39 100.0 3.500 544.03 12.58 Sand 15.89 2.61 100.0 3.500 -274.97 17.23 Sand 18.50 2.50 100.0 4.000 -346.50 19.78 Shear and Moments Along Pier Distance below Shear Moment Shear Moment Top of Pier (with Safety Factor) (with Safety Factor) (without Safety Factor) (without Safety Factor) (ft) (kips) (ft-k) (kips) (ft-k) 0.00 50.4 3909.3 16.2 1261.1 2.10 48.1 4013.9 15.5 1294.8 4.20 38.0 4105.7 12.3 1324.4 6.30 4.5 4162.0 1.5 1342.6 8.40 -73.1 4094.2 -23.6 1320.7 10.50 -190.8 3822.6 -61.6 1233.1 12.60 -337.0 3273.2 -108.7 1055.9 14.70 -511.0 2387.6 -164.8 770.2 16.80 -530.2 1190.3 -171.0 384.0 18.90 -294.1 314.3 -94.9 101.4 21.00 0.0 0.0 0.0 0.0 K,,,,; = 1,343.7 Kip-ft (Moment for DSMC sheet) Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral, transverse reinforcing Site Data Maximum Shaft Superimposed Forces BU#: 879602 TIA Revision: G Site Name: Barrows Rd, OR Max. Factored Shaft Mu: 1343.7 App#: 150758; Rev: 0 Max. Factored Shaft Pu: 16 kips Max Axial Force Type: Comp. (*)Note: Max Shaft Superimposed Moment does not necessarily Loads Already Factored equal to the shaft top reaction moment For M (WL) <----Disregard For P (DL) <----Disregard Load Factor Shaft Factored Loads 1.00 Mu: 1343.7 ft-kips Pier Properties 1.00 Pu: 16 kips Concrete: Pier Diameter= 6.0 ft Material Properties Concrete Area = 4071.5 in2 Concrete Comp. strength. fc= 3000 psi Reinforcement yield strength, Fy= 60 ksi Reinforcement: Reinforcing Modulus of Elasticity, E = 29000 ksi Clear Cover to Tie= 4.00 in Reinforcement yield strain = 0.00207 Horiz. Tie Bar Size= 4 Limiting compressive strain =I 0.003 Vert. Cage Diameter= 5.13 ft ACI 318 Code Vert. Cage Diameter = 61.59 in Select Analysis ACI Code=[ 2008 Vertical Bar Size = 11 Seismic Properties Bar Diameter= 1.41 in Seismic Design Category= D Bar Area = 1.56 in2 Seismic Risk = High Number of Bars = 16 As Total= 24.96 in2 Solve <--Press Upon Completing All Input A s/Aconc, Rho: 0.0061 0.61% (Run) ACI 10.5 , ACI 21.10.4, and IBC 1810. Results: Min As for Flexural, Tension Controlled, Shafts: Governing Orientation Case: 1 (3)*(Sgrt(fc)/Fy: 0.0027 200/ Fy: 0.0033 /`�'� �L���.J IBC 1810.1.2: 0.0050 SDC D, E. or F Mu /L'��� Mu /Y Governing: 0.0050 0.50% I ACI 10.8 and 10.9 }- ' Min As for Columns, Comp. Controlled. Shafts: Min As: 0.0100 1.00% Case 1 Case 2 Dist. From Edge to Neutral Axis: 12.22 in Minimum Rho Check: _ Extreme Steel Strain, et: 0.0134 Actual Req'd Min. Rho: 0.50% Flexural et> 0.0050, Tension Controlled Provided Rho: 0.61% OK Reduction Factor,cp: 0.900 <-- Comment Box Ref. Shaft Max Axial Capacities, (I) Max(Pn or Tn): Max Pu = (cp=0.65) Pn. Output Note: Negative Pu=Tension Pn per ACI 318 (10-2) 6144.47 kips For Axial Compression, cp Pn = Pu: 16.00 kips at Mu=(cI)=0.65)Mn= 3168.27 ft-kips Drilled Shaft Moment Capacity, cpMn: 3286.74 ft-kips Drilled Shaft Superimposed Mu: 1343.70 ft-kips Max Tu, (cp=0.9) Tn = 1347.84 kips at Mu=4=(0.90)Mn= 0.00 ft-kips (MukpMn, Drilled Shaft Flexure CSR: I 40.88% Drilled_Shaft_Moment_Capacity, DSMC, Version 1.1 - Effective 04/01/2010 Analysis Date: 7/13/2012 July 13, 2012 di B+T GRP • Ms. Cathy Garziano B&T Engineering, Inc. Crown Castle 1717 S. Boulder, Suite 300 5350 North 48th Street Suite 305 Tulsa, OK 74119 Chandler, AZ 85226 (918) 587-4630 (480) 735-6952 ctuttle @btengineering.com Subject: Structural Analysis Report Carrier Designation: Sprint PCS Co-Locate Carrier Site Number: PO54XC011 Carrier Site Name: N/A Crown Castle Designation: Crown Castle BU Number: 879602 Crown Castle Site Name: Barrows RD Crown Castle JDE Job Number: 179416 Crown Castle Work Order Number: 496950 Crown Castle Application Number: 150758 Rev. 4 Engineering Firm Designation: B&T Engineering, Inc. Project Number: 78702.001 Site Data: 16744 SW Scholls Ferry Road, Beaverton,Washington County, OR Latitude 45°25'34.61", Longitude-122°50'53.85" 100 Foot-Monopole Tower Dear Ms. Garziano, • B+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural 'Statement of Work' and the terms of Crown Castle Purchase Order Number 467312, in accordance with application 150758, revision 0. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Existing + Proposed Equipment Sufficient Capacity Note:See Table 1 and Table 2 for the proposed and existing loading,respectively. The analysis has been performed in accordance with the TIA-222-G standard and the 2010 Oregon Structural Specialty Code (2009 IBC) based upon a wind speed of 95 mph 3-second gust, exposure category C with topographic category 1 and crest height of 0 feet. All equipment proposed in this report shall be installed in accordance with the attached drawings for the determined available structural capacity to be effective. We at B+T Group appreciate the opportunity of providing our continuing professional services you and Crown Castle. If you have any questions or need further assistance on this or any other projects Are give us a call. Respectfully submitted by: A0,11 %L .: 76P It i ,cGON Raul Ortiz Jr., E.I.T. Chad E. Tuttle, P.E 11101',7:i'v �cp; Project Engineer President �13 Y'<; 'ID 711� `� tnxTower Report-version 6.0.4.0 ,�J Expira . j �f ""�'�' July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CC/BU No. 879602 Project Number 78702.001,Application 150758, Revision 4 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2)ANALYSIS CRITERIA Table 1 -Proposed Antenna and Cable Information Table 2-Existing Antenna and Cable Information Table 3-Design Antenna and Cable Information 3)ANALYSIS PROCEDURE Table 4-Documents Provided 3.1)Analysis Method 3.2)Assumptions 4)ANALYSIS RESULTS Table 5-Section Capacity (Summary) Table 6-Tower Component Stresses vs. Capacity 4.1) Recommendations 5)APPENDIX A tnxTower Output 6)APPENDIX B Base Level Drawing 7)APPENDIX C Additional Calculations tnxTower Report-version 6.0.4.0 July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CCI BU No. 879602 Project Number 78702.001,Application 150758, Revision 4 Page 3 • 1) INTRODUCTION This tower is a 100 ft. Monopole tower designed by Summit in April of 2001. The tower was originally designed . for a wind speed of 85 mph per TIA/EIA-222-F. 2) ANALYSIS CRITERIA The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind speed of 95 mph with no ice, 30 mph with 1.25 inch ice thickness and 60 mph under service loads, exposure category C with topographic category 1 and crest height of 0 feet. Table 1 - Proposed Antenna and Cable Information Center Number Number Feed Mounting Line Antenna Level (ft) Elevation of Manufacturer Antenna Model of Feed Line Note l (ft) Antennas Lines Size (in) . , Powerwave 3 P65-16-XLPP-RR I Technologies 1 J I 1 1 Dragonwave , Horizon Compact Plus 98.0 100.0 1 Andrew VHLP2-18 3 17/16 -- 1 13/64 3 Telecommuni cations RRH-C2C w/Ext Filter 3 Samsung RRH-P4 Telecommunications' Table 2 - Existing Antenna and Cable Information Center Number Number Feed Mounting Line of Antenna Antenna Model of Feed Line Note Level (ft) Elevation Manufacturer i (ft) Antennas Lines Size (in) 100.0 6 Ems Wireless RR65-19-02DP 6 1 1/4 2 98,0 98.0 1 -- Platform Mount[LP 714-1]T -- -- r 1 I 3 Ems Wireless RR33-20-00DP 90.0 90.0 3 Ems Wireless RR65-19-00DP 18 7/8 1 1 ' -- T-Arm Mount[TA 602-3] Kathrein 840 85.0 I- 4 85.0 4 Clearwire 1 Type IV BTS 5 5/16 1 1 Radiowaves 1 HP2-23 1 1/2 82.0 1 1 Trimble ACUTIME 2000 Notes: 1) Existing Equipment 2) Equipment to be Removed Table 3- Design Antenna and Cable Information Center Mounting Line Number Antenna Number Feed of Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer Lines Size (in) i (ft) - - 100 100 1 — 14' Low Profile Platform — — 12 EMS I RV90-17-OODP Pcs Panel tnxTower Report-version 6.0.4.0 July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CCI BU No. 879602 Project Number 78702.001, Application 150758, Revision 4 Page 4 Center Number Number Feed Mounting Line Antenna of Antenna Model of Feed Line Level (ft) Elevation Antennas Manufacturer (ft) Lines Size (in) 90 90 1 I 14' Low Profile Platform 12 EMS RV90-17-00DP Pcs Panel 80 80 1 -- 14' Low Profile Platform 12 I EMS RV90-17-00DP Pcs Panel 3) ANALYSIS PROCEDURE Table 4- Documents Provided Document Remarks Reference Source Online Application Sprint Co-Location Revision #0 150758 CCI Sites Tower Manufacturing Drawings Summit Manufacturing , LLC 1625431 CCI Sites Job.29201-0364 Foundation/Geotechnical Data Job.29201-0364 Summit Manufacturing , LLC 1486071 CCI Sites Antenna Configuration I Crown CAD Package Date:06/05/2012 CCI Sites 3.1) Analysis Method tnxTower(version 6.0.4.0), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer's specifications. 2) The tower and structures have been maintained in accordance with the manufacturer's specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) Mount areas and weights are assumed based on photographs provided. This analysis may be affected if any assumptions are not valid or have been made in error. B&T Engineering, Inc. should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 5 -Section Capacity (Summary) Section Elevation(ft) Component Size Critical I P(K) ISF'P allow % I Pass/Fail No. Type Element (K) Capacity L1 100-72.75 Pole TP26.088x22x0.188 1 -5.669 1023.680 33.1 Pass L2 72.75-36 Pole TP31.227x25.225x0.219 2 -9.502 1415.830 65.5 Pass L3 36-0 Pole TP36.19x30.189x0.25 3 -15.245 1886.610 80.5 Pass Summary Pole(L3) 80.5 Pass Rating= 80.5 Pass tnxTower Report-version 6.0.4.0 July 13, 2012 100 Ft Monopole Tower Structural Analysis Report CCI BU No. 879602 Project Number 78702.001, Application 150758. Revision 4 Page 5 Table 6-Tower Component Stresses vs. Capacity— LC5 Notes Component Elevation (ft) % Capacity Pass/ Fail 1 Anchor Rods Base 63.1 Pass 1 Base Plate Base 62.6 1 Pass 1 I Base Foundation Base 38.1 Pass Structure Rating (max from all components) = 80.5% Notes 111 1) See additional documentation in"Appendix C—Additional Calculations"for calculations supporting the%capacity consumed. 2) Capacities up to 105%are considered acceptable based on analysis methods used. 4.1) Recommendations N/A tnxTower Report-version 6.0.4.0 APPENDIX A TNXTOWER OUTPUT 100.011 �',' , DESIGNED APPURTENANCE LOADING TYPE I ELEVATION I TYPE I ELEVATION Lighting Rod(E) 102 RR65-19-00DP w/Mount Pipe(E) 90 P65-16-XLPP-RR wl Mount Pipe(P) 98 RR6Si9-000P wl Mount Pipe(E) 90 ■ 1 1 A 1 1— .. P65-16-XLPP-RR wl Mount Pipe(P) i 98 RR6S19-000P w/Mount Pipe(E) 90 P65-16-XLPP-RR w/Mount Pipe(P) 98 (2)6'x 2"Mount Pipe(E) 90 RRH-C2C w/EXT FILTER(P) 98 (2)6'x 2'Mount Pipe(E) 90 I1I RRH-C2C w/EXT FILTER(P) 98 (2)6'x 2°Mount Pipe(E) 90 Yl WP_.. $ 8 RRH-C2C w/EXT FILTER(P) 98 _+T-Arm Mount[TA 602-3](E) 90 • V ! z ° RRH-P4(P) 98 I RR33-20-00DP w/Mount Pipe(E) 90 N o en N 4 __... ... __ rV IV RRH-P4(P) 198 840 10057 w/Mount Pipe(E) 185 . RR H-P4(P) _ 98 (2)840 10057 w/Mount Pipe(E) 85 Horizon Compact(P) 98 ACUTIME 2000(E) i 85 ((2)6'x 2"Mount Pipe(E(Flnal)) 98 Pips Mount(PM 601-3](E) I85 (2)6'x 2"Mount Pipe(E(Flnal)) 98 Type IV BTS(E) 85 (216'n 2"Mount Pipe(E(Final)) 98 Type IV BTS(E) 85 Petrone Mount[LP 714-1](E) 98 Type IV BTS(E) 85 T / R 72.8 1 VHLP2-18(P) 98 HP2-23(E)w! 85 ._ _.. / RR33-20-000Pw/Mount Rpm(E) 90 940 10057 Mount Pipe(E) 85 T 1 RR33-20.00OP lei Mount Pipe(E) 90 MATERIAL STRENGTH GRADE I Fy I Fu GRADE I Fy I Fu l A607-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in Washington County,Oregon. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 95 mph basic wind in accordance with the TIA-222-G Standard. Q 4. Tower is also designed for a 30 mph basic wind with 1.25 in ice.Ice is considered to increase 8 in thickness with height. N S l 4 ! 1. n 5. Deflections are based upon a 60 mph wind. N A ; a 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.000 ft O 8. TOWER RATING:80.5% • / J 38.OR �...L._. • ALL REACTIONS ARE FACTORED 4 S S S AXIAL to `t m o R i ei 41K SHEAR MOMENT 2 K ( j 156 kip-ft TORQUE 0 kip-ft 30 mph WIND-1.250 in ICE AXIAL /15 K SHEAR' \ MOMENT 14 K li ` 1111 kip-ft OA R g * TORQUE 1 kip-ft REACTIONS-95 mph WIND i II J J r B+T Group ob 78702.001-Barrows Rd, OR(BU#879602) J 1717 S. Boulder,Suite 300 P'Dfe"low Summit Monopole/App ID:150758;Rev:0 B'T Tulsa,OK 74119 Client Crown Castle Drawn by.Rortiz Aped: ' Phone:(918)587-4630 Code: TIA-222-G Date:07/1112 Seale: NTS FAX: 918 295-0265 Path: Dwg No.E-1 TIA-222-G -95 mph/30 mph 1.250 in Ice Exposure C Maximum Values Vx Vz Mx Mz • Global Mast Shear(K) Global Mast Moment (kip-ft) 0 5 10 15 0 500 1000 1500 • 109.000 72.7511_ + + + + + + 72,750 • C 0 it W 35.0(X 30.000 1 1 0:000 i -.-........__....—�. p:000 • d 0 5 10 15 0 500 1000 1500 B+T Group Job 78702.001-Barrows Rd, OR(BU#879602) 1717 S. Boulder,Suite 300 Pmj•ct 100'Summit Monopole/App 10:150758;Rev:0 s•r GRP Tulsa, OK 74119 Chem Crown Castle Drawn by.Rortiz App'd: Phone:(918)587-4630 Cod" TIA-222-G °me:07/13/12 U4°' NTS FAX: 918 295-0265 Path °wg No.E-4 TIA-222-G - Service -60 mph Maximum Values M Deflection (in) Tilt (deg) Twist (deg) 0 5 10 15 0 0.5 1 1.5 0 0.05 0.1 100.000 - ____ r--r-_! -T— /, 1.00:900 � � I l l I l l 1 1 1 f I I I I I I I I I I I I I 1 I I I ' 4 I I I I I I I I I I I I I 1 I I I I I I I I 1 1 1 1 1 I I 1 I I I I 1 1 I I I I 1 1 1 I 1 1 i 1 I I I I I I I I I - I I I I I 1 1 1 1 I I 1 1 I I I I 1 I 1 I I 1 I 1 1 I i 1 I I I I 1 I 1 11 I 1 1 1 1 1 I I 1 I ! I I 1 1 I / I 1 I 1 I 1 I 1 I 1 I 1 I I I 1 1 I I I I I I I I I I I I 1 I I I I I I I I I 1 I 1 I 1 I I I I I I I I I I I 1 1 I 1 1 1 1 I I I 1 I 1 1 I 1 I I I 1 1 I 1 . I I 1 1 1 I I I i I I I I I 1 I I I I I I 1 1 I 1 1 1 1 ) 11 I 1 1 I 1 1 I I I 1 1 72.75 I I-, � 1 I I i 1 I I 1 I I I _ -I- _- I I I I 78.750 I I I 1I 1 I I I I I 1 'I I I I I� I I I I 1 1 I i 1 1 1 1 I 1/ I 1 1 I I V I I 1 I I I I p 1 I I I' I I 1 I 1 1 I I 1 /1 I I I I I f I I I I d 1 1 I 1 1 /I I I I I I 1 I I I I I '' 1 'I 8 I 1 1 1 I I 1 I I I 1 I 'I 1 I I I I I I Y I I I I 1 I I 1 I I 1 I I I I I I I Y I 'I I 1 1 1 1 I I I I i I I r 1 1 I I I 'I I I 1 I I 1 I I 1 I I I I I v I I I I I I1' 1 I I I I I I I I I I I I I Ii ;C / I 1 I I I I I% I I I I I I I I I I I I I I 0 n 1 1 1 1 § I I I I ,rI I I I' 1 I I I I I I I I I I 1 1 I/��1 I I 1 I I I I I I I 1 I I W 1, 1 I 1; 1 1 1 I 1 I I I 1 I I I I I I I I I I' I I I P 1 1 I I 1 I I I I I I i I 1 /1 1 I I I I I I I 1 I I I 1 I I I ' II II 0 I 1 I k 1 1 I I 1 I I I 1 I i j1 1'. 11 1 / 1 I I' I I I 1 I I I 1 I I I 1 1 36 000 I I I V 38.000 , 1 I 1 1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1/ I I I I I I I I I I I I I I I I I f I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I / 1 I I I I I I I I I I I I I I I I I It I I I I I I I I I I I I I I I I I I I Yj I I 1 I I I I 1 I I I 1 I I I 1 I , '' I %I I I I I I i I 1 I I I 1 I I 1 I I I I 1 1 I I I 1 I I I 1 I I I I I,' I 1 1 1 I I 1 I I 1 1 I I I I I I,' 1 I I I € ! I I 1 I I I 1 I I I 1 I 1 I I I ! R I I I I I 1 I I 1 I I I 11 I I I I I i I I I I I 1 1 I I I 1 I ' /t 1 I I I I 1 I I I 1 I I I I I I I I I 1 i / I I I 11 I I I 1 1 I I I I I 1 I I I I I I I 1 I I I I I I I I I , 1 i 1 I 1 1 1 1 I I 1 I I I I I I I 1 I ' /� 1 1 1 1 I I I I I 1 I I 1 I I I I I I I 04 o. -...._...i_... ._._._ -'...___'� ' I 1 I I I 1 I I I I I I 0 1 I I 1 I I i I 0,000 5 0 5 10 15 0 0.5 1 1.5 0.05 0.1 B+T Group Jo° � 78702.001-Barrows Rd, OR(BINS 879602) j 1717 S.Boulder,Suite 300 P°I°°t 100'Summit Monopole/App ID:150758;Rev:0 B'T Tulsa,OK 74119 Cher Crown Castle D "'a b"Rortiz App'd: ra Phone:(918)587-4630 Code' TIA-222-G Date.07/13/12 Ss" NTS ' FAX:(918)295-0265 Path..,.,..,. r•_,r,,,.,o,,,-.,,w,...„.,,,,,...,„„m,..,-.,,s,.,..._.,.?Mg No.E 5 Feedline Distribution Chart 0' - 100' App Out Face Truss Leg • Face A Face B Face C .i 100.000- 98 000_ _ 98_ 90000 e0.000 e5.000 85.000 '. l I -i 72.750 72.750 I E. ce re 6 w a 2 ,` m a U W U OJ w m 0 Q 6 Y o 36 000 1 i1 5.000 5000_....-- i 1 0000 ------ -._.. 0.000 i ti r B+T Group yob'78702.001-Barrows Rd,OR(BU#879602) 1717 S. Boulder, Suite 300 Project 100'Summit Monopole/App ID:150758;Rev:0 s•T GRF' Tulsa,OK 74119 Chent: Crown Castle Orewn by:ROrtiZ App'd: Phone:(918)587-4630 Code' TIA-222-G °"):07/13/12 scal.: NTS FAX:(918)295-0265 Path °w°No.E_7 . - — - », w. 4 �m, w.� .... tnxToweY Job Page 78702.001 - Barrows Rd, OR(BU#879602) 1 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100'Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle Rortlz FAX:(918)295-0265 Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Washington County,Oregon. Basic wind speed of 95 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.000 ft. Nominal ice thickness of 1.250 in. Ice thickness is considered to increase with height. Ice density of 56.000 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50.000°F. Deflections calculated using a wind speed of 60 mph. A non-linear(P-delta)analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads,feedline supports,and appurtenance mounts are not considered. • Options Consider Moments-Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder Consider Moments-Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules Consider Moments-Diagonals -4 Assume Rigid Index Plate Calculate Redundant Bracing Forces Use Moment Magnification Ai Use Clear Spans For Wind Area Ignore Redundant Members in FEA Use Code Stress Ratios Use Clear Spans For KL/r SR Leg Bolts Resist Compression ' Use Code Safety Factors-Guys Retension Guys To Initial Tension All Leg Panels Have Same Allowable Escalate Ice -4 Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz 4 Use Azimuth Dish Coefficients 4 Consider Feedline Torque Use Special Wind Profile ' Project Wind Area of Appurt. Include Angle Block Shear Check Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles Leg Bolts Are At Top Of Section SR Members Have Cut Ends 4 Include Shear-Torsion Interaction Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets Add IBC.6D+W Combination Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in LI 100,000-72.750 27.250 3.250 18 22.000 26.088 0.188 0.750 A607-65 (65 ksi) L2 72.750-36.000 40.000 4.000 18 25.225 31.227 0.219 0.875 A607-65 (65 ksi) L3 36.000-0.000 40.000 18 30.189 36.190 0.250 1.000 A607-65 (65 ksi) Job Page tnYTower 78702.001 - Barrows Rd, OR (BU#879602) 2 of 10 B+T Group Project Date 1717 S.Boulder.Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 Tulsa.OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX (918)295-0265 ROrtIZ Tapered Pole Properties Section TO Dia. Area I r C I/C J It/Qr w wit in in in' in in in3 ins in in L 22.339 12.981 780.301 7.743 11.176 69.819 1561.628 6.492 3.542 18.891 26.490 15.414 1306.382 9.195 13.253 98.575 2614.482 7.708 4.261 22.728 L2 26.110 17.366 1372.011 8.877 12.815 107.067 2745.828 8.685 4.055 18.531 31.709 21.534 2615.901 11.008 15.863 164.903 5235.245 10.769 5.111 23.359 L3 31.264 23.757 2690.338 10.628 15.336 175.425 5384.216 11.881 4.873 19.493 36.748 28.518 4653.917 12.759 I8.385 253.143 9313.957 14.262 5.929 23.718 Tower Gusset Gusset Gusset Grade Adjust.Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness At Factor Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Diagonals Horizontals f fi2 in in in LI 1 1 1 100.000-72.75 0 L2 1 1 1 72.750-36.000 L3 I I 1 36.000-0.000 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description Sector Component Placement Tom( ;Vumber Start/End Width or Perimeter Weight Type Number Per Row Position Diameter ft in in klf s/s 2"Rigid Conduit C Surface Ar 85.000-5.000 2 2 0.000 2.000 0.003 (E) (CaAa) 0.000 s/s Safety Line 3/8 C Surface Ar 100.000-0.000 I I 0.000 0.375 0.000 (E) (CaAa) 0.000 s/s Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CAAA Weight or Shield Type Number Leg It fzft k(f TYPE 2(1-7/16) A No Inside Pole 98.000-5.000 3 No Ice 0.000 0.001 (P) 1/2"Ice 0.000 0.001 1"Ice 0.000 0.001 2"Ice 0.000 0.001 CATEGORY 5e(1 A No Inside Pole 98.000-5.000 1 No Ice 0.000 0.000 WIRE) 1/2"Ice 0.000 0.000 (P) I"Ice 0.000 0.000 2"Ice 0.000 0.000 s/s LDF5-50A(7/8") C No Inside Pole 90.000-5.000 18 No Ice 0.000 0.000 (E) 1/2"Ice 0.000 0.000 I"Ice 0.000 0.000 2"Ice 0.000 0.000 LDF4-50A(1/2") C No Inside Pole 85.000-5.000 1 No Ice 0.000 0.000 tnXTower Job Page 78702.001 - Barrows Rd, OR(BU#879602) 3 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtIZ Description Face Allow Component Placement Total C4A.4 Weight or Shield Type Number Leg ft ftI/ft k/f (E(Inside Conduit)) 1/2"Ice 0.000 0.000 1"Ice 0.000 0.000 2"Ice 0.000 0.000 ATCB-B01-001(5/16") C No Inside Pole 85.000-5.000 5 No Ice 0.000 0.000 (E(Inside Conduit)) 1/2"Ice 0.000 0.000 1"Ice 0.000 0.000 2"Ice 0.000 0.000 «/* Feed Line/Linear Appurtenances Section Areas Tower Tower Face AR A, C4A.4 CAA Weight Section Elevation In Face Out Face ft fr' ft2 ft` fr' K LI 100.000-72.750 A 0.000 0.000 0.000 0.000 0.051 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 5.922 0.000 0.183 L2 72.750-36.000 A 0.000 0.000 0.000 0.000 0.074 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 16.078 0.000 0.451 L3 36.000-0.000 A 0.000 0.000 0.000 0.000 0.062 B 0.000 0.000 0.000 0.000 0.000 " C 0.000 0.000 13.750 0.000 0.382 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice AR At- CIA CAA.1 Weight Section Elevation or Thickness In Face Out Face ft Leg in ft' ft2 Jr' ft2 K L 1 100.000-72.750 A 2.751 0.000 0.000 0.000 0.000 0.051 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 30.567 0.000 0.722 L2 72.750-36.000 A 2.627 0.000 0.000 0.000 0.000 0.074 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 65.252 0.000 1.594 L3 36.000-0.000 A 2.354 0.000 0.000 0.000 0.000 0.062 B 0.000 0.000 0.000 0.000 0.000 C 0.000 0.000 56.120 0.000 1.326 Feed Line Center of Pressure Section Elevation CPx CPz CPx CPz Ice Ice ft in in in in L 1 100.000-72.750 0.000 0.322 0.000 0.894 L2 72.750-36.000 0.000 0.583 0.000 1.190 L3 36 000-0 000 0.000 0.520 0.000 1.204 T Job Page tnx ower 78702.001 - Barrows Rd, OR (BU# 879602) 4 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 • Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle Rortiz FAX:(918)295-0265 Shielding Factor Ka Tower Feed Line Description Feed Line Ka K Section Record No. _Segment Elev. No Ice Ice LI 7 2"Rigid Conduit 72.75-85.00 1.0000 1.0000 LI 12 Safety Line 3/8 72.75-100.00 1.0000 1.0000 L2 7 2"Rigid Conduit 36.00-72.75 1.0000 1.0000 L2 12 Safety Line 3/8 36.00-72.75 1.0000 1.0000 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CAA.4 CAA.4 Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ft jt' ft` K ft p Lighting Rod C None 0.000 102.000 No Ice 0.375 0.375 0.030 (E) 1/2"Ice 0.890 0.890 0.034 I"Ice 1.356 1.356 0.041 2"Ice 1.993 1.993 0.066 r/s P65-16-XLPP-RR w/Mount C From Leg 4.000 0.000 98.000 No Ice 8.637 6.362 0.075 " Pipe 0.000 1/2"Ice 9.290 7.538 0.137 (P) 2.000 1"Ice 9.910 8.427 0.212 2"Ice 11.176 10.239 0.389 P65-16-XLPP-RR w/Mount B From Leg 4.000 0.000 98.000 No Ice 8.637 6.362 0.075 Pipe 0.000 1/2"Ice 9.290 7.538 0.137 (P) 2.000 1"Ice 9.910 8.427 0.212 2"Ice 11.176 10.239 0.389 P65-16-XLPP-RR w/Mount A From Leg 4.000 0.000 98.000 No Ice 8.637 6.362 0.075 Pipe 0.000 1/2"Ice 9.290 7.538 0.137 (P) 2.000 I"Ice 9.910 8.427 0.212 2"Ice 11.176 10.239 0.389 RRH-C2C w/EXT FILTER C From Leg 4.000 0.000 98.000 No Ice 3.087 5.542 0.052 (P) 0.000 1/2"Ice 3.346 5.859 0.090 2.000 1"Ice 3.613 6.185 0.132 2"Ice 4.174 6.864 0.230 RRH-C2C w/EXT FILTER B From Leg 4.000 0.000 98.000 No Ice 3.087 5.542 0.052 (P) 0.000 1/2"Ice 3.346 5.859 0.090 2.000 1"Ice 3.613 6.185 0.132 2"Ice 4.174 6.864 0.230 RRH-C2C w/EXT FILTER A From Leg 4.000 0.000 98.000 No Ice 3.087 5.542 0.052 (P) 0.000 1/2"Ice 3.346 5.859 0.090 2.000 1"Ice 3.613 6.185 0.132 2"Ice 4.174 6.864 0.230 RRH-P4 C From Leg 4.000 0.000 98.000 No Ice 3.191 2.075 0.060 (P) 0.000 1/2"Ice 3.439 2.292 0.083 2.000 1"Ice 3.696 2.517 0.109 2"Ice 4.235 2.994 0.172 RRH-P4 B From Leg 4.000 0.000 98.000 No Ice 3.191 2.075 0.060 (P) 0.000 1/2"Ice 3.439 2.292 0.083 2.000 I"Ice 3.6% 2.517 0.109 i. 2"Ice 4.235 2.994 0.172 RRH-P4 A From Leg 4.000 0.000 98.000 No Ice 3.191 2.075 0.060 (P) 0.000 1/2"Ice 3.439 2.292 0.083 2.000 1"Ice 3.696 2.517 0.109 i. 2"Ice 4.235 2.994 0.172 Horizon Compact C From Leg 4.000 0.000 98.000 No Ice 0.841 0.429 0.012 IL J tnxTower ob Page 78702.001 - Barrows Rd, OR (BU#879602) 5 of 10 B+T Group Project Date 1717 S.Boulder,Suite300 100' Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 • Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX (918)295-0265 ROrtIZ Description Face Offset Offsets: Azimuth Placement C,A.4 C4A,a Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ft IF jt2 K .t jt (P) 0.000 1/2"Ice 0.966 0.525 0.018 2.000 1"Ice 1.099 0.629 0.026 2"Ice 1.392 0.863 0.048 (2)6'x 2"Mount Pipe C From Leg 4.000 0.000 98.000 No Ice 1.425 1.425 0.022 (E(Final)) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 I"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 (2)6'x 2"Mount Pipe B From Leg 4.000 0.000 98.000 No Ice 1.425 1.425 0.022 (E(Final)) 0.000 1/2"Ice 1,925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 (2)6'x 2"Mount Pipe A From Leg 4.000 0.000 98.000 No Ice 1.425 1.425 0.022 (E(Final)) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 Platform Mount[LP 714-1] C None 0.000 98.000 No Ice 37.470 37.470 1.600 (E) 1/2"Ice 44.230 44.230 2.040 1"Ice 50.990 50.990 2.480 2"Ice 64.510 64.510 3.360 s/s RR33-20-00DP w/Mount C From Leg 4.000 0.000 90.000 No Ice 7.238 5.661 0.044 Pipe 0.000 1/2"Ice 7.792 6.545 0.100 (E) 0.000 I"Ice 8.333 7.306 0.166 2"Ice 9.446 8.949 0.322 RR33-20-00DP w/Mount B From Leg 4.000 0.000 90.000 No Ice 7.238 5.661 0.044 Pipe 0.000 1/2"Ice 7.792 6.545 0.100 (E) 0.000 I"Ice 8.333 7.306 0.166 2"Ice 9.446 8.949 0.322 RR33-20-00DP w/Mount A From Leg 4.000 0.000 90.000 No Ice 7.238 5.661 0.044 Pipe 0.000 1/2"Ice 7.792 6.545 0.100 (E) 0.000 1"Ice 8.333 7.306 0.166 2"Ice 9.446 8.949 0.322 RR65-19-00DP w/Mount C From Leg 4.000 0.000 90.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 (E) 0.000 I"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 RR65-19-00DP w/Mount B From Leg 4.000 0.000 90.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 (E) 0.000 1"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 RR65-19-00DP w/Mount A From Leg 4.000 0.000 90.000 No Ice 6.104 4.412 0.042 Pipe 0.000 1/2"Ice 6.666 5.624 0.086 (E) 0.000 1"Ice 7.194 6.496 0.141 2"Ice 8.273 8.273 0.278 (2)6'x 2"Mount Pipe C From Leg 4.000 0.000 90.000 No Ice 1.425 1.425 0.022 (E) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 (2)6'x 2"Mount Pipe B From Leg 4.000 0.000 90.000 No Ice 1.425 1.425 0.022 (E) 0.000 1/2"Ice 1.925 1.925 0.033 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 (2)6'x 2"Mount Pipe A From Leg 4.000 0.000 90.000 No Ice 1.425 1.425 0.022 (E) 0.000 1/2"Ice 1.925 1.925 0.033 .1 0.000 1"Ice 2.294 2.294 0.048 2"Ice 3.060 3.060 0.090 . T-Arm Mount[TA 602-3] C None 0.000 90.000 No Ice 11.590 11.590 0.774 ■ i ( Job Page tnxTower 78702.001 - Barrows Rd, OR (BU#879602) 6 of 10 B+T Group Project Date 1717 S.Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX.(918)295-0265 ROrtIZ Description Face Offset Offsets: Azimuth Placement CA.a CIA, Weight or Type Horz Adjustment Front Side Leg Lateral Vert ft ft ft' 112 K ft ft (E) 1/2"Ice 15.440 15.440 0.990 1"Ice 19.290 19.290 1.206 2"Ice 26.990 26.990 1.639 s1s 840 10057 w/Mount Pipe C From Leg 1.500 0.000 85.000 No Ice 2.718 2.351 0.026 (E) 0.000 1/2"Ice 3.095 2.883 0.051 0.000 1"Ice 3.483 3.431 0.083 2"Ice 4.290 4.578 0.163 840 10057 w/Mount Pipe B From Leg 1.500 0.000 85.000 No Ice 2.718 2.351 0.026 (E) 0.000 1/2"Ice 3.095 2.883 0.051 0.000 1"Ice 3.483 3.431 0.083 2"Ice 4.290 4.578 0.163 (2)840 10057 w/Mount Pipe A From Leg 1.500 0.000 85.000 No Ice 2.718 2.351 0.026 (E) 0.000 1/2"Ice 3.095 2.883 0.051 0.000 1"Ice 3.483 3.431 0.083 2"Ice 4.290 4.578 0.163 ACUTIME 2000 C From Leg 1.500 0.000 85.000 No Ice 0.297 0.297 0.001 (E) 0.000 1/2"Ice 0.374 0.374 0.005 -3.000 l"Ice 0.459 0.459 0.010 2"Ice 0.655 0.655 0.025 Pipe Mount[PM 601-3] A From Leg 1.500 0.000 85.000 No Ice 4.390 4.390 0.195 • (E) 0.000 1/2"Ice 5.480 5.480 0.237 0.000 I"Ice 6.570 6.570 0.280 2"Ice 8.750 8.750 0.365 "/* Type N BTS C From Leg 1.500 0.000 85.000 No Ice 3.033 2.275 0.045 (E) 0.000 1/2"Ice 3.284 2.506 0.068 0.000 I"Ice 3.543 2.746 0.094 2"Ice 4.088 3.252 0.156 Type N BTS B From Leg 1.500 0.000 85.000 No Ice 3.033 2.275 0.045 (E) 0.000 1/2"Ice 3.284 2.506 0.068 0.000 I"Ice 3.543 2.746 0.094 2"Ice 4.088 3.252 0.156 Type IV BTS A From Leg 1.500 0.000 85.000 No Ice 3.033 2.275 0.045 (E) 0.000 1/2"Ice 3.284 2.506 0.068 0.000 1"Ice 3.543 2.746 0.094 2"Ice 4.088 3.252 0.156 Dishes Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight or Type Type Horz Adjustment Beam Diameter Area Leg Lateral Width Vert ft ° ft ft f 2 K HP2-23 A Paraboloid From 2.000 -90.000 85.000 2.042 No Ice 3.274 0.027 (E) w/Shroud(HP) Leg 0.000 1/2"Ice 3.547 0.045 -3.000 1"Ice 3.819 0.063 2"Ice 4.365 0.100 •/. VHLP2-18 C Paraboloid w/o From 2.000 0.000 98.000 2.175 No Ice 3.715 0.031 (P) Radome Leg 0.000 1/2"Ice 4.006 0.052 • 2.000 1"Ice 4.296 0.072 2"Ice 4.876 0.113 1 L Job Page tnxTower 78702.001 - Barrows Rd, OR (BU#879602) 7 of 10 B+T Group Project Date 17175 Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 • Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROriIZ Load Combinations Comb. h, , No. I Dead Only 2 1.2 Dead+1.6 Wind 0 deg-No Ice 3 0.9 Dead+1.6 Wind O deg-No Ice 4 1.2Dead+1.6 Wind 30 deg-NoIce 5 0.9 Dead+1.6 Wind 30 deg-No Ice 6 1.2 Dead+1.6 Wind 60 deg-No Ice 7 0.9 Dead+1.6 Wind 60 deg-No Ice 8 1.2 Dead+1.6 Wind 90 deg-No Ice 9 0.9 Dead+1.6 Wind 90 deg-No Ice 10 1.2 Dead+1.6 Wind 120 deg-No Ice 11 0.9 Dead+1.6 Wind 120 deg-No Ice 12 1.2 Dead+l.6 Wind 150 deg-No Ice 13 0.9 Dead+1.6 Wind 150 deg-No Ice 14 1.2 Dead+1.6 Wind 180 deg-No Ice 15 0.9 Dead+1.6 Wind 180 deg-No Ice 16 1.2 Dead+1.6 Wind 210 deg-No Ice 17 0.9 Dead+l.6 Wind 210 deg-No Ice 18 1.2 Dead+1.6 Wind 240 deg-No Ice 19 0.9 Dead+1.6 Wind 240 deg-No Ice 20 1.2 Dead+1.6 Wind 270 deg-No Ice 21 0.9 Dead+1.6 Wind 270 deg-No Ice 22 1.2 Dead+1.6 Wind 300 deg-No Ice 23 0.9 Dead+1.6 Wind 300 deg-No Ice 24 1.2 Dead+1.6 Wind 330 deg-No Ice 25 0.9 Dead+1.6 Wind 330 deg-No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+l.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+l.0Ice+1.0 Temp 39 Dead+Wind 0 deg-Service 40 Dead+Wind 30 deg-Service 41 Dead+Wind 60 deg-Service 42 Dead+Wind 90 deg-Service 43 Dead+Wind 120 deg-Service 44 Dead+Wind 150 deg-Service 45 Dead+Wind 180 deg-Service 46 Dead+Wind 210 deg-Service 47 Dead+Wind 240 deg-Service 48 Dead+Wind 270 deg-Service 49 Dead+Wind 300 deg-Service 50 Dead+Wind 330 deg-Service Job Page tnxTower 78702.001 - Barrows Rd, OR (BU# 879602) 8 of 10 B+T Group Project Date 1717 S.Boulder,Suite300 100'Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 ' Tulsa,OK 74119 Client Designed by Phone:(918)587-4630 Crown Castle FAX-(918)295-0265 RortIZ Maximum Member Forces Section Elevation Component Condition Gov. Axial Major Axis Minor Axis No. ft Type Load Moment Moment Comb. K kip-fi kip-ft LI 100-72.75 Pole Max Tension 1 0.000 0.000 0.000 Max.Compression 26 -21.681 0.882 1.157 Max.Mx 8 -5.675 -172.532 4.389 Max.My 2 -5.695 -5.862 171.193 Max.Vy 8 9.880 -172.532 4.389 Max.Vx 2 -9.728 -5.862 171.193 Max.Torque 8 1.206 L2 72.75-36 Pole Max Tension 1 0.000 0.000 0.000 Max.Compression 26 -30.316 0.957 -0.539 Max.Mx 8 -9.505 -571.678 9.992 Max.My 2 -9.518 -14.528 564.520 Max.Vy 8 12.256 -571.678 9.992 Max.Vx 2 -12.103 -14.528 564.520 Max.Torque 8 1.205 L3 36-0 Pole Max Tension 1 0.000 0.000 0.000 Max.Compression 26 -41.172 0.957 -2.411 Max.Mx 8 -15.245 -1107.676 16.001 Max.My 2 -15.245 -23.942 1094.121 Max.Vy 8 14.428 -1107.676 16.001 Max.Vx 2 -14.280 -23.942 1094.121 Max.Torque 8 1.201 • Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt 71 r No. Deflection Load ft in Comb. ° LI 100-72.75 13.661 41 1.073 a uu3 L2 76-36 8.422 41 0.973 0.002 L3 40-0 2.467 41 0.555 0.001 Critical Deflections and Radius of Curvature - Service Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ft 102.000 Lighting Rod 41 13.661 1.073 0.003 37818 100.000 VHLP2-18 41 13.661 1.073 0.003 37818 98.000 P65-16-XLPP-RR w/Mount Pipe 41 13.213 1.068 0.003 37818 90.000 RR33-20-00DP w/Mount Pipe 41 11.428 1.044 0.003 18909 85.000 840 10057 w/Mount Pipe 41 10.331 1.025 0.003 12606 82.000 HP2-23 41 9.684 1.010 0.003 10505 L Job Page tnxTower 78702.001 - Barrows Rd, OR(BU#879602) 9 of 10 B+T Group Project Date /717 S.Boulder,Suite 300 100'Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 • Tulsa,OK 741/9 Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtIZ Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. 0 L1 100-72.75 61.502 6 4.839 0.015 L2 76-36 37.933 6 4.388 0.011 L3 40-0 11.119 6 2.502 0.004 Critical Deflections and Radius of Curvature - Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in 0 ft 102.000 Lighting Rod 6 61.502 4.839 0.015 8538 100.000 VHLP2-18 6 61.502 4.839 0.015 8538 98.000 P65-16-XLPP-RR w/Mount Pipe 6 59.484 4.815 0.015 8538 90.000 RR33-20-00DP w/Mount Pipe 6 51.456 4.707 0.014 4268 85.000 840 10057 w/Mount Pipe 6 46.522 4.618 0.014 2844 82.000 HP2-23 6 43.610 4.553 0.013 2370 Compression Checks Pole Design Data Section Elevation Size L L. K/Jr A P„ OP„ Ratio No. P. ft ft ft in2 K K 1011. LI 100-72.75(1) TP26.088x22x0.188 27.250 0.000 0.0 15.124 -5.669 1023.680 0.006 L2 72.75-36(2) TP31.227x25.225x0.219 40.000 0.000 0.0 21.118 -9.502 1415.830 0.007 L3 36-0(3) TP36.19x30.189x0.25 40.000 0.000 0.0 28.518 -15.245 1886.610 0.008 Pole Bending Design Data Section Elevation Size M. OM_ Ratio M„ OM„„ Ratio No. M M..„ 31 441 kiv ft +M kip-ft kipii OM„ LI 100-72.75(1) TP26.088x22x0.188 173.898 535.202 0.325 0.000 535.202 0.000 L2 72.75-36(2) TP31.227x25.225x0.219 574.178 885.883 0.648 0.000 885.883 0.000 L3 36-0(3) TP36.19x30.189x0.25 1111.392 1395.533 0.796 0.000 1395.533 0.000 • Job Page tnxTower 78702.001 - Barrows Rd, OR (BU#879602) 10 of 10 IProject Date B+T Group 1717 S.Boulder,Suite 300 100' Summit Monopole/App ID: 150758; Rev: 0 14:52:40 07/13/12 Or Tulsa,OK 74119 ' Client Designed by Phone:(918)587-4630 Crown Castle FAX:(918)295-0265 ROrtIZ Pole Shear Design Data Section Elevation Size Actual 4V Ratio Actual 4T Ratio No. V. V T T ft K K 0V. +yap-.lt lap-.R 4T L 1 100-72.75(1) TP26.088x22x0.188 9.917 51 1.839 0.019 1.112 1071.717 0.001 L2 72.75-36(2) TP3I.227x25.225x0.219 12.291 707.914 0.017 1.109 1773.933 0.001 L3 36-0(3) TP36.19x30.189x0.25 14.462 943.303 0.015 1.106 2794.483 0.000 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. P„ M M„, V„ T Stress Stress ft $P, $M, 4M,. 4V +T Ratio Ratio L I 100-72.75(1) 0.006 0.325 0.000 0.019 0.001 0.331 1.000 4.8.2 I/ L2 72.75-36(2) 0.007 0.648 0.000 0.017 0.001 0.655 1.000 482 V L3 36-0(3) 0.008 0.796 0.000 0.015 0.000 0.805 1.000 4.8.2 ✓' I✓ Section Capacity Table Section Elevation Component Size Critical P ePat„. % Pass No. .ft Type Element K K Capacity Fail L 1 100-72.75 Pole TP26.088x22x0.188 1 -5.669 1023.680 33.1 Pass L2 72.75-36 Pole TP31.227x25.225x0.219 2 -9.502 1415.830 65.5 Pass L3 36-0 Pole TP36.19x30.189x0.25 3 -15.245 1886.610 80.5 Pass Summary Pole(L3) 80.5 Pass RATING= 80.5 Pass Program Version 6.0.4.0-1/27/2012 File:78702_001_Barrows RdOR_Final Loading.eri APPENDIX B BASE LEVEL DRAWING • • / __ \ / / \ / / \ \ PROPOSED)D)TO 98 FT LEVEL . / / \ \ 3� 1-7 16' TO 98 FT LEVEL • / \ \ INSTALLED-TO BE REMOVED) 6) 1-1/4" TO 98 FT LEVEL Of 1 1 • Q Q, 1 1 NOT INSTALLED) : ` ` 0? I I N) L / TO 85 FT LEVEL \ \ / / 1 1/2"EDTO 85 FT LEVEL e \ / / 5; 5/16' TO 85 FT LEVEL t+ \ \ / / \ \ i V / \ - / (18)T 77/8)TO 90 FT LEVEL I feI BUSINESS UNIT: 879602 TOWER ID: C_BASELEVEL APPENDIX C ADDITIONAL CALCULATIONS Square, Stiffened / Unstiffened Base Plate, Any Rod Material - Rev. F /G Assumptions: 1)Rod groups at corners. Total#rods divisible by 4. Maximum total#of rods=48(12 per Corner). 2)Rod Spacing=Straight Center-to-Center distance between any(2)adjacent rods(same corner) 3)Clear space between bottom of leveling nut and top of concrete not exceeding(1)*(Rod Diameter) Site Data Base Reactions BU#: 879602 TIA Revision: G Site Name: Barrows Rd, OR Factored Moment,Mu: 1111 ft-kips App#: 150758;Rev:0 Factored Axial, Pu: 15 kips Anchor Rod Data Factored Shear, Vu: 14 kips Eta Factor, r) 0.5 TIA G(Fig.4-4) Qty: 8 Diam: 2.25 in Anchor Rod Results Rod Material: A615-J TIA G--> Max Rod(Cu+Vu/n): 164.1 Kips Yield, Fy: 75 ksi Axial Design Strength, *Fu*Anet: 260.0 Kips Strength, Fu: 100 ksi Anchor Rod Stress Ratio: 63.1% _Bolt Circle: 42 _in Anchor Spacing: 6 in Plate Data Base Plate Results Flexural Check PL Ref. Data W=Side: 41 in Base Plate Stress: 31.0 ksi Yield Line(in): Thick: 2.25 in PL Design Bending Strength, c*Fy: 49.5 ksi _ 21.79 Grade: 55 ksi Base Plate Stress Ratio: 62.6% Max PL Length: Clip Distance: 6 in 21.79 NIA-Unstiffened _ Stiffener Data(Welding at both sides) Stiffener Results Configuration: Unstiffened Horizontal Weld : N/A Weld Type: ** Vertical Weld: N/A Groove Depth: in"" Plate Flex+Shear,fb/Fb+(fv/Fv)^2: N/A Groove Angle: degrees Plate Tension+Shear,ft/Ft+(fv/Fv)^2: N/A Fillet H. Weld: <--Disregard Plate Comp. (AISC Bracket): N/A Fillet V. Weld: . in Pole Results Width: in Pole Punching Shear Check: N/A • Height: in Ma• PL Length Thick: in Yield Line Notch: in Ir Anchors of corner= Os BASE PL Grade: ksi Oty/4 1111 THICKNESS Weld str.: ksi AilE111,110 q.Anchor, Typ. STIFFENED CONFIGURATION ASSUMED IN TppL Pole Data � 2Anchor case of B.C. ror 51D>�a #of Sides: 18 "0"IF Round IM Pole w/ P�� DIAM = D Anchor Spacing Same As Stiffener Spacing, 1 11 Except for sianle Comer Anchor (Input Clear Space) **Note:for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes CClplate 1.5-Square Base F-G 1.2, Effective March 19,2012 Analysis date: 7/13/2012 ! * • • A CAISSON Version 10.35 3:02:57 PM Friday, July 13, 2012 B&T Engineering ************************************************************************************************** * * * CAISSON - Pier Foundations Analysis and Design - Copyright Power Line Systems, Inc. 1993-2010 * * * ************************************************************************************************** Project Title: 78702.001 - Barrows Rd, OR (BU# 879602) Project Notes: 100' Summit Monopole- 6' Dia, 21' Minimum Depth(20.5' Bearing) Calculation Method: Full 8CD ******* I N P U T D A T A Pier Properties Diameter Distance Concrete Steel of Top of Pier Strength Yield above Ground Strength (ft) (ft) (ksi) (ksi) 6.00 0.50 Soil Properties Layer Type Thickness Depth at Top Density CU KP PHI of Layer (ft) (ft) (lbs/ft^3) (psf) (deg) 1 Sand 5.00 0.00 100.0 1.000 2 Sand 3.00 5.00 100.0 3.000 30.00 3 Sand 10.00 8.00 100.0 3.500 33.75 4 Sand 10.00 18.00 100.0 4.000 36.87 Design (Factored) Loads at Top of Pier Moment Axial Shear Additional Safety Load Load Factor Against Soil Failure (ft-k) (kips) (kips) 1111.0 15.0 14.00 . :o Z 1.333 (F.S.) , Soil Interaction = (1.333/3.50)x 100% = 38.1% ******* R E S U L T S Calculated Pier Properties Length Weight End Bearing Pressure (ft) (kips) (psf) 21.000 89.064 530.5 Ultimate Resisting Forces Along Pier Type Distance of Top of Layer Thickness Density CU EP Force Arm to Top of Pier (ft) (ft) (lbs/ft^3) (psf) (kips) (ft) Sand 0.50 5.00 100.0 1.000 22.50 3.83 Sand 5.50 3.00 100.0 3.000 105.30 7.12 Sand 8.50 7.38 100.0 3.500 543.64 12.58 Sand 15.88 2.62 100.0 3.500 -275.36 17.22 Sand 18.50 2.50 100.0 4.000 -346.50 19.78 Shear and Moments Along Pier Distance below Shear Moment Shear Moment Top of Pier (with Safety Factor) (with Safety Factor) (without Safety Factor) (without Safety Factor) (ft) (kips) (ft-k) (kips) (ft-k) 0.00 49.6 3922.0 14.2 1120.6 2.10 47.3 4024.8 13.5 1150.0 4.20 37.3 4115.0 10.6 1175.7 6.30 3.7 4169.7 1.1 1191.3 8.40 -73.9 4100.1 -21.1 1171.5 10.50 -191.6 3826.9 -54.8 1093.4 12.60 -337.8 3275.8 -96.5 935.9 . 14.70 -511.8 2388.6 -146.2 682.5 16.80 -530.2 1190.3 -151.5 340.1 18.90 -294.1 314.3 -84.0 89.8 21.00 0.0 0.0 0.0 0.0 M = 1,192.1 Kip-ft (Moment for DSMC sheet) I Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral, transverse reinforcing Site Data Maximum Shaft Superimposed Forces BU#: 879602 TIA Revision: G . Site Name: Barrows Rd, OR Max. Factored Shaft Mu: 1192.1 App#: 150758; Rev: 0 Max. Factored Shaft Pu: 15 kips Max Axial Force Type. Comp. (*) Note: Max Shaft Superimposed Moment does not necessarily Loads Already Factored equal to the shaft top reaction moment For M (WL) <----Disregard For P(DL) <----Disregard Load Factor Shaft Factored Loads 1.00 Mu: 1192.1 ft-kips Pier Properties 1.00 Pu:_ 15 kips Concrete: Pier Diameter= 6.0 ft Material Properties Concrete Area = 4071.5 in2 Concrete Comp strength, fc= 3000 psi Reinforcement yield strength, Fy = 60 ksi Reinforcement: Reinforcing Modulus of Elasticity, E= 29000 ksi Clear Cover to Tie= 4.00 in Reinforcement yield strain = 0.00207 Horiz. Tie Bar Size= 4 Limiting compressive strain =I 0.003 Vert. Cage Diameter= 5.13 ft ACI 318 Code Vert. Cage Diameter= 61.59 in Select Analysis ACI Code=1 2008 Vertical Bar Size = 11 1 Seismic Properties Bar Diameter = 1.41 in Seismic Design Category = D j Bar Area = 1.56 in2 Seismic Risk = High Number of Bars = 16 As Total= 24.96 in2 Solve <--Press Upon Completing All Input _ A s/Aconc, Rho: 0.0061 0.61% (Run) ACI 10.5 , ACI 21.10.4, and IBC 1810 Results: • Min As for Flexural, Tension Controlled, Shafts: Governing Orientation Case: 1 (3)*(Sgrt(fc)/Fy: 0.0027 200/ Fy: 0.0033 / IAi∎� IBC 1810.1.2: 0.0050 SDC D. E, or F Mu Il'r�1 Mu ��. Governing: 0.0050 0.50% T I - - , r ( - 1 ,• • ACI 10.8 and 10.9 -- ' Min As for Columns, Comp. Controlled, Shafts: 1 Min As: 0.0100 1.00% Case 1 Case 2 Dist. From Edge to Neutral Axis: 12.21 in Minimum Rho Check: Extreme Steel Strain, et: 0.0134 Actual Req'd Min. Rho: 0.50% Flexural et> 0.0050, Tension Controlled Provided Rho: 0.61% OK Reduction Factor,T: 0.900 <-- Comment Box _ Ref Shaft Max Axial Capacities, Max(Pn or Tn): Max Pu = (q=0.65) Pn. Output Note: Negative Pu=Tension • Pn per ACI 318 (10-2) 6144.47 kips For Axial Compression, q Pn = Pu: 15.00 kips at Mu=(T=0.65)Mn=_ 3168.27 ft-kips Drilled Shaft Moment Capacity, cpMn: 3284.63 ft-kips _ Drilled Shaft Superimposed Mu: 1192.10 ft-kips • Max Tu, (cp=0.9) Tn = 1347.84 kips at Mu=T=(0.90)Mn= 0.00 ft-kips (MuhpMn, Drilled Shaft Flexure CSR: I 36.29% Drilled_Shaft_Moment_Capacity, DSMC, Version 1.1 - Effective 04/01/2010 Analysis Date: 7/13/2012