Plans RECEIVE]) HOME LAYOUT/SITE PLAN MAY 142014 P rj'?F`s%i ��. _. . ,.uMPLIANCE CITY OF TIGARD BUILDING DIVISION I I ka..2 4/ tAc 00227 14T�y X. J i f (Ice suite #: � g Date: � OFFICE COPY L 1 3 cc© 5 S Pr e. 5<1.-- STREET QV °r4 CITY OF TIGARD Approved by Planning Date: 5--l" Init.. s: , ,, puirmum. N4A3 araMffgitu Performance Series HEATING & COOLING PRODUCTS °"""'' Product S • ecificatons EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT MAY 14 2014 11/2 THRU 5 TONS SPLIT SYSTEM _ I FTIGARD 208 / 230 Volt, 1-phase, 60 Hz VISION REFRIGERATION CIRCUIT ,, : `. • Copeland® compressors on all models • Filter-Drier supplied with every unit for field installation ' i I l r Alm If 13 111111111111111111 . /I • Copper tube / aluminum fin coil h� �{,� i � , f, EASY TO INSTALL AND SERVICE ft1IIi i I I I { ; 1)'• Easy Access service valves on all models �. I NI'` i • External high and low refrigerant service ports k IN II,II I i • Only two screws to access control panel v i i • Factory charged with R-410A refrigerant BUILT TO LAST I;I N 11111111 ti . • Baked-on powder coat finish over galvanized steel ;'• Post-painted (black) coil fins �, • Coated, weather-resistant cabinet screws 1M • Coated inlet grille with 2" (51 mm) spacing standard, alternate models available with 3/8" (10mm) grille spacing for extra protection Aim: ar . •Iits (12) WARRANTY* pERfoRMANCt C US • 5 year compressor limited warranty cdsrd11Eo "°'""'""°nISTED UnIWt Ale Co,..,,u•tlwn • 5 year parts limited warranty (including compressor Rated in accordance with ARI and coil) Standard 210/240 Certification applies only when used with proper - With timely registration, an additional 5 year parts components as listed with ARI limited warranty (including compressor and coil) *Applies to original purchaser/homeowner, some limitations may apply. See Warranty certificate for complete details. Model Size Nominal Min. Circuit Max. Fuse Operating Dimensions Ship I Operating Number (tons) BTU/hr Ampacity or Breaker height x width x depth in. (mm) Weight lbs. (kg) N4A318AKB 11/2 18,000 11.8 20 255/6 x 23% x 231/a 130 / 107 18GKB same model with 3/8" (10mm)spacing inlet grille (643 x 587 x 587) (59 /49) N4A324AKB 2 24,000 17.6 25 255/6 x 23Ya x 23Ya 134 / 110 24GKB same model with 3/8" (10mm) spacing inlet grille (643 x 587 x 587) (61 / 50) N4A330AKC 21/2 30,000 I 16.8 25 281%16 x 23% x 23Y8 136 / 111 30GKC same model with 3/8" (10mm) spacing inlet grille (729 x 587 x 587) (62/ 50) N4A336AKB 3 36,000 21.5 30 3113/6 x 253/4 x 253/4 170/ 141 36GKB same model with 3/8" (10mm) spacing inlet grille (808 x 654 x 654) (77/64) N4A342AKA 31/2 42,000 I 23.5 40 325/16 x 3136 x 313/,6 208/ 180 42GKA same model with 3/8" (10mm) spacing inlet grille (821 x 792 x 792) (94 / 82) N4A348AKB 4 48,000 I 26.2 40 353/4 x 313/16 x 313/6 216/ 179 C -. e model with 3/8" (10mm) spacing inlet grille (908 x 792 x 792) (98 / 81) 4A360AKC 60,000 34.2 50 251 x 313/6 x 313/6 218 / 184 60GKC =ame model with 3/8" (10mm) spacing inlet grille (648 x 792 x 792) (99 / 84) Specifications subject to change without notice 421 11 5102 02 July 7nrlq -o 7) N _ 0 Aso. M 0 c AIR IN AIR 0 AIR DISCHARGE 0 DISCHARGE -I \ t / — j m m n 3 ! o 1---.1._ 8 CENTER OF GRAVITY ,�5:•�■ D �<.. 0 0 FIELD CONTROL '� AIR IN- - gfeol."1 SUPPLY CONN. ,, __ , ■B 957/8' HOLE L.,,.... FIELD POWER SUPPLY CONN. r � /����J F AIR Ih 0 7/8" HOLE WITH ` m 0 1 1/8' KNOCKOUT , , `,� `�- PIs s..//, ' N o LIQUID LINrCONN. if � O � .y```�■=,�,,,, C 3 1/2' J 1 7/8" t I .d � 1 i 1 t i a f L1 01)VAPOR LINE CONN. m 5/16' '#3/8' TIEDOWN KNOCKOUTS (2) PLACES 5 K AIR IN 9.' A R Dimensions Inches (English) �Cl Model Minimum Crated (* = A or G) A B C D E F G K L M N P Mounting Dimensions Cl) Pad Size B(h) x A(w) x R(d) o N4A318*KB 231/8 255/16 33/4 3/4 4%16 18'/16 713/16 213/16 1/2 16'/2 15 12 23Y2 x 23Y2 331/2 x 273/8 x 24'/4 3 N4A324*KB 23'/8 255/16 33/4 3A 4%16 18'/16 713/16 213/16 '1 16Y2 15 12 231 x 231 33Y2 x 27% x 24% ' n N4A330*KC 23%8 28'Y16 33/4 3/4 4%16 18%16 713/16 213A6 Y2 16'1 15 14 23Y2 x 23Y2 33'1 x 27% x 24% . 0 i0 o. N4A336*KB 253/4 3113/16 37/8 /8 69/16 21% 91/8 215/16 5/8 14% 10Y2 16 26 x 26 3515/16 x 301/16 x 26%8 ''; a; N4A342*KA 313/16 325/16 3%8 %8 69/16 24'%s 9% 215/16 5/8 153/4 1614 133/4 311 x 32Y2 3515/16 x 35'1 x 323/8 r .4. ' 3/16 353/4 3% 78 69/16 24'%16 9% 2i5/16 5/s 143/4 15% 15 31'1 x 31'1 39% x 351 x 32% ._: a) ■L-12 14A360*KC+ 13/16 251/2 3% %8 69/16 241%16 91/8 _ 215/16 5/8 14% 15% 113/4 311/2 x 311/2 329/1s x 351/2 x 32% A Z N D 0 w N 4 4 ,4h. PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A3 PHYSICAL DATA Model Size 18 24 30 36 42 48 :/ 60 Nominal Cooling Capacity (BTU/hr) 18,000 24,000 30,000 36,000 42,000 48,000 , 00 Nominal SEER 13.0 13.0 13.0 13.0 13.0 13.0 13.0 ' Sound Rating (dBA)** 72 76 74 75 78 80 78 PSC Fan Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/4 • Fan RPM (single speed) 1100 1100 1100 1100 1100 1100 800 Fan CFM 1792 2218 2218 2954 3167 3365 3365 Coil Face Area ft2(m2) 8.40 8.40 9.80 13.13 17.25 19.40 12.93 (.78) (.78) (.91) (1.22) (1.6) (1.8) (1.2) Coil Rows - fins per inch 1 - 20 1 - 25 1 - 25 1 - 25 1 - 25 1 - 25 2 - 20 Liquid Line Connection Size in. (mm) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) Vapor Line Connection Size in. (mm) 3/4 (19) 3/4 (19) 3/4 (19) 7/8 (22) 7/8 (22) 7/8 (22) 7/8 (22) Recommended Line Set Liquid Tube 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) 3/8 (10) Diameter in. (mm) Recommended Line Set Vapor Tube 3/4 (19)* 3/4 (19)* 3/4 (19)* 7/8 (22)* 7/8 (22)* 7/8 (22)* 1% (29)* Diameter in. (mm) * Recommended Vapor Tube Line size is for standard installations. These recommendations may not apply to "Long Line" installations. When the total equivalent line length exceeds 80 feet (24.4m)or there is more than 20 feet (6.1m) vertical separation between indoor and outdoor units, consult the Long Line Application Guideline document before purchasing/installing line sets. Factory Charge R-410A lbs. (kg) 3.50 3.80 4.10 5.34 5.84 7.00 8.19 (1.59) (1.72) (1.86) (2.42) (2.65) (3.18) (3.71) Required Subcooling °F (°C) 10 (6) 10 (6) 10 (6) 14 (8) 10 (6) 15 (8) 13 (7) Weight, shipping lbs. (kg) 130 (59) 134 (61) 136 (62) 170 (77) 208 (94) 216 (98) 218 (99) 4c- , Weight, operating lbs. (kg) _ 107 (49) 110 (50) _ 111 (50) 141 (64) 180 (82) 179 (81) 184 (84) ELECTRICAL DATA (208/230-1-60, voltage range 197V - 253V) Model Size 18 24 30 36 42 48 60 Minimum Circuit Ampacity - 11.8 17.6 16.8 21.5 ! 23.5 26.2 34.2 MCA (amps) Maximum OverCurrent 20 25 25 30 40 40 50 Protective device - MOCP (amps) Compressor RLA (Rated Load Amps) 9.0 13.5 12.8 15.3 17.9 19.9 26.4 LRA (Locked Rotor Amps) 48.0 58.3 64.0 77.0 112.0 109.0 134.0 Fan Motor FLA (Full Load Amps) .5 .77 .77 1.4 1.1 1.4 1.2 **Sound Rating tested in accordance with ARI Standard 270-95 (not listed with ARI). . r 4 Specifications subiect to chanoe without notice 421 11 5102 02 PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A3 Ft-410A COOLING CAPACITY LOSS FOR VARIOUS LINE LENGTHS & TUBE DIAMETERS Cooling Capacity Loss (%) at Total Equivalent Line Length, feet (m) Acceptable Liquid Refer to Long Line Application Guideline to calculate equivalent length Model Line Vapor Line Standard A pp lication Lon g Line A pp lication (Requires Accessories)Sizes in.(mm) in (mm) 25' 50' 80' 81' 100' 125' 150' 175' 200' 225' 250' (7.6) (15.2) (24.4) (24.7) (30.5) (38.1) (45.7) (53.3) (61) (68.6) (76.2) 1/2 (13) 1 2 3 3 4 6 7 8 9 10 12 • 18 5/8 (16) 0 0 1 1 1 1 2 2 3 3 3 3%(19) 0 0 0 0 0 1 1 1 1 1 2 24 % (16) 0 1 1 1 2 3 3 4 4 5 6 3/4(19) 0 0 0 0 0 1 1 1 1 1 2 5/8(16) 1 2 3 3 3 4 5 6 7 8 9 30 3/4 (19) 0 0 1 1 1 1 2 2 2 3 3 %8 (22) 0 0 0 0 0 1 1 1 1 1 1 5/8(16) 1 2 4 4 5 6 7 9 10 11 13 36 3/s (10) 3/4 (19) 0 0 1 1 1 2 2 3 3 4 4 78 (22) 0 0 0 0 0 1 1 1 1 2 2 42 3/ (19) 0 1 2 2 2 3 4 4 5 6 _ 6 %8 (22) 0 0 1 1 1 1 2 2 2 3� 3 48 3/4 (19) 0 1 2 2 3 4 5 5 6 7 8 7/8 (22) 0 0 1 1 1 2 2 2 3 3 4 3A (19) 1 2 4 4 5 6 7 9 10 11 12 60 78 (22) 0 1 2 I 2 2 3 4 4 5 I 5 I 6 I 1%8 (29) 0 0 0 11 0 1 1 1 1 1 I 1 I 2 *A.. 'cations are considered "Long Line"if the total equivalent tubing length exceeds 80 feet (24.4m)or there is more an 20 foot (6.1m) vertical separation between indoor and outdoor units. These applications require additional ■ accessories and system modifications for reliable system operation. Applications in shaded area may have height restrictions that limit allowable total equivalent length when outdoor unit is below indoor unit. ACCESSORY USAGE GUIDELINES REQUIRED FOR REQUIRED FOR Accessory LOW-AMBIENT APPLICATIONS LONG-LINE APPLICATIONS* {Below 55°F (13°C)) {Over 80 ft. (24.4m)} Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Winter Start Control Yes ** No Hard Start Kit (Capacitor& Relay) Yes Yes Low Ambient Kit (Pressure Switch) Yes No Support Feet, 4" (102mm)tall Recommended No Liquid Line Solenoid Valve _ No See Long-Line Application Guideline * For Line Set lengths between 80 and 200 ft (24.4 and 61m) horizontal, or more than 20 ft (6.1m) indoor-outdoor vertical separation, refer to the Long Line Application Guideline document. ** Can only be installed in conjunction with Low Pressure Switch. 491 11 RICO f19 Specifications subject to chance without notice. c PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A3 COOLING PERFORMANCE FOR COMBINATION RATINGS (continued) Indoor Models Outdoor Current Cooling 95°F(35°C) SEER Indoor Model Furnace Factory - Model Model Installed BTU/hr S/T EER factory Ail field 'woo! (I tested combo) TDR N4A348AKB ED*4X48L" '9MPV125 TDR&TXV 45,500 0.71 11.50 13.50 N4A348GKB ED'4X48L" '9MVX100 TDR&TXV 45,000 0.71 11.50 13.50 (continued) ED'4X48L" MV20L24"B' TDR&TXV 45,500 0.71 12.00 14.00 ED'4X48L" t TXV 46,000 0.71 11.00 13.20 ED'4X60J" '8MPV100 TDR&TXV 46,000 0.71 11.70 14.00 ED'4X60J" '8MPV125 TDR&TXV 46,000 0.71 12.00 14.00 ED*4X60J" *9MPV100 TDR&TXV 46,000 0.71 11.70 13.50 ED'4X60J" '9MVX080 TDR&TXV 46,500 0.71 11.70 13.50 ED'4X60J" MV16J22"B' TDR&TXV 46,000 0.71 12.20 14.50 ED*4X60J" t TXV 46,000 0.71 11.20 13.20 ED*4X60L" '9MPV125 TDR&TXV 46,500 0.71 11.70 13.50 ED*4X60L" *9MVX100 TDR&TXV 46,000 0.71 11.70 13.50 ED*4X60L" MV20L24"B' TDR&TXV 46,500 0.71 12.20 14.50 ED°4X60L" t TXV 46,500 0.71 11.20 13.20 EHD4X48A- '8MPV100 TDR&TXV 46,000 0.71 11.50 13.50 EHD4X48A" '8MPV125 TDR&TXV 46,000 0.71 11.70 13.50 EHD4X48A" '9MPV100 TDR&TXV 45,500 0.71 11.20 13.20 EHD4X48A" '9MPV125 TDR&TXV 45,500 0.71 11.50 13.50 EHD4X48A" '9MVX080 TDR&TXV 45,500 0.71 11.20 13.20 EHD4X48A" '9MVX100 TDR&TXV 45,000 0.71 11.50 13.50 EHD4X48A- MV16J22"B' TDR&TXV 46,000 0.71 12.00 14.00 EHD4X48A'" MV20L24"B' TDR&TXV 46,000 0.71 12.00 14.00 EHD4X48A" t TXV 46,000 0.71 11.00 13.20 EHD4X60A" '8MPV100 TDR&TXV 46,500 0.71 11.70 14.00 EHD4X60A" '8MPV125 TDR&TXV 46,500 0.71 12.00 14.00 EHD4X60A" '9MPV100 TDR&TXV 46,500 0.71 11.70 13.50 EHD4X60A" '9MPV125 TDR&TXV 46,500 0.71 11.70 13.50 tilt EHD4X60A" '9MVX080 TDR&TXV 46,500 0.71 11.70 13.50 EHD4X60A" '9MVX100 TDR&TXV 46,000 0.71 11.70 13.50 e EHD4X60A" MV16J22"B* TDR&TXV 46,500 0.71 12.20 14.50 EHD4X60A" MV20L24"B' . TDR&TXV 46,500 0.71 12.20 14.50 EHD4X60A" t TXV 46,500 0.71 11.20 13.20 EMA4X48D" t TXV 45,000 0.71 11.00 13.20 FEM4X48"" t TDR&TXV 46,500 - 0.71 11.70 13.50 FEM4X60"" t TDR&TXV 47,500 0.71 12.00 14.00 FS(M,U)4X48`"' t TDR&TXV 45,500 0.71 11.20 13.20 FS(M,U)4X60""' t TDR&TXV 46,500 0.71 11.20 13.20 FVM4X48"" t TDR&TXV 46,000 0.71 12.00 14.00 FVM4X60"" t TDR&TXV 46,500 0.71 12.20 14.50 N4A360AKC #ED*4X60L" t TXV 57,500 0.74 11.00 13.00 N4A360GKC ED'4X60J" '9MVX080 TDR&TXV • 56,000 0.74 11.00 13.00 ED*4X60J" MV16J22"B' TDR&TXV 57,000 0.74 11.20 13.50 f_� ED'4X60J" t TXV 57,500 0.74 11.00 13.00 ED*4X60L" MV20L24"B' TDR&TXV 57,000 0.74 11.20 13.20 EHD4X60A"' '9MVX080 TDR&TXV 56,000 0.74 11.00 13.00 EHD4X60A" MV16J22"B' TDR&TXV 57,500 0.74 11.50 13.50 EHD4X60A" MV20L24"B' TDR&TXV 57,000 0.74 11.20 13.20 EHD4X60A" t TXV ' 57,500 0.74 11.00 13.00 FEM4X60'"` t TDR&TXV - 57.500 0.74 11.20 13.20 FVM4X60"" t TDR&TXV 57,500 0.74 11.50 13.50 2009 ENERGY STAR compliance for combinations with both:SEER 14.50 or higher and EER 12.00 or higher t For coils not listed with a matching furnace or blower,coil rating applies with any indoor blower device. For complete ratings information,use the AHRI website directory search:www.AHRldirectoryorg. (Occasionally,new ratings will be lis- ted online before Specification Sheets are updated.) i This product EEN been designed and manufac- lured to meet ENERGY STAR criteria for energy efficiency ne when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency Installaron of this product should follow the manufacturers refn- ENERGY STAR gerant charging and air flow instructions Failure PARTNER 10 confirm proper charge and airflow may reduce energy efficiency and shorten equipment life. A91 11 c,1 n9 n/ Specifications subject to chance without notice. 1.: