Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
RECEIVED JUN - 4 2014 v � OF TIGARD 41440W• • • % JtJ VAT 1iuNGie1ISION FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 WASHINGTON SQUARE TOO : INFILL 9585 SW WASHINGTON SQUARE TIGARD, OREGON 97EnornGA� REVIEWED FOR CODE COMPLIANCE Approved& f t J OTCs i J Permit#s Zv( - 9 Address (�)2C , 1 Suite#t By:Ths. Dates (O OFFICE COPY FIRE PROTECTION EQUIPMENT SUBMITTAL • Vico Worldwide Fire Protection Contacts www.tyco-fire.com v Products Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers - Standard Response, Standard Coverage General NOTICE The Series TY-B Sprinklers described "`P i• Ti Description herein must be installed and maintained in compliance with this document, as _.__ The TYCO Series TY-B, 5.6 K-factor, well as with the applicable standards "� Upright(TY315)and Pendent(TY325) of the National Fire Protection Associa- Sprinklers described in this data sheet tion,in addition to the standards of any ' '" i 4 are standard response,standard cover- other authorities having jurisdiction. ° age,decorative 5 mm glass bulb type Failure to do so may impair the perfor- spray sprinklers designed for use in mance of these devices. \. '� light, ordinary, or extra hazard, corn- The owner is responsible for maintain- • mercial occupancies such as banks, po ;_ hotels, shopping malls, factories, ing their fire protection system and -- - refineries,and chemical plants. devices in proper operating condition. The installing contractor or sprinkler The recessed version of the Series manufacturer should be contacted with TY-B Pendent Sprinkler, where appli- any questions. cable,is intended for use in areas with a finished ceiling.This recessed pendent Sprinkler -'�` "R _sprinkler uses one of the following: p A• A two-piece Style 15 Recessed Identification i Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm)from ,,. �' the flush pendent position. Numbers (SINS) _ • A two-piece Style 20 Recessed TY315 Upright 5.6K, 1/2-NPT Escutcheon with recessed adjust- TY325 Pendent 5.6K, 1/2-NPT 4 ,, ment up to 1/2 inch (12,7 mm)from , the flush pendent position. Technical The adjustment provided by the Temperature Ratings Recessed Escutcheon reduces the Data 135°F(57°C) accuracy to which the fixed pipe drops 155°F(68°C) Approvals 175°F 7 to the sprinklers must be cut. PP (79°C) UL and C-UL Listed 200°F(93°C) Intermediate level versions of Series FM, LPCB,and VdS Approved 286°F(141°C) TY-B Sprinklers are described in CE Certified 360°F(182°C)t Technical Data Sheet TFP352.Sprinkler guards and shields are described in Sprinklers with Polyester Finish are t UL,C-UL,and VdS Approved only Technical Data Sheet TFP780. UL and C-UL Listed as Corrosion- Finishes Resistant Sprinklers. Sprinkler:Refer to Table A Maximum Working Pressure Recessed Escutcheon:White Coated, 175 psi(12.1 bar) Chrome Plated,or Brass Plated 250 psi(17.2 bar)` `The maximum working pressure of 250 psi Physical Characteristics (17.2 bar)only applies to the listing by Un- Frame Bronze IMPORTANT derwriters Laboratories,Inc.(UL). Button Brass/Copper Always refer to Technical Data Sealing Assembly Stainless Sheet TFP700 for the "INSTALLER Discharge Coefficient Steel w/TEFLON WARNING" that provides cau K=5.6 GPM/psi��z(80,6 LPM/barl�) Bulb Glass tions with respect to handling and Compression Screw Bronze installation of sprinkler systems and Deflector Bronze components.improper handling and installation can permanently dam- - age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP152 TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 'V 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* f';/.'=i.....:.. „r,-,tI,1;1,x,,, 5 =I 7/16" _' (11,1 mm) 1 tuF • 4 NOMINAL I Il MAKE-IN (50,8 mm)2 D 2" / 1-3/8" L 3 tI (50,8 mm) I (34,9 mm) I `W WRENCH / ! FLATS 1/2"NPT** DEFLECTOR* I— 2-7/8"(73,0 mm)DIA. — CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT,STANDARD RESPONSE �, Operation Installation The glass bulb contains a fluid which The TYCO Series TY-B, 5.6 K-factor, - 0/"'../ WRENCH RECESS expands when exposed to heat.When Upright(TY315)and Pendent(TY325) (USE ONLY the rated temperature is reached,the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. glass bulb, allowing the sprinkler to FIGURE 2 activate and water to flow. General Instructions Do not install any bulb type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss of SPRINKLER WRENCH Design liquid from the bulb.With the sprinkler held horizontally, a small air bubble WRENCH Criteria should be present.The diameter of the W RCNS air bubble is approximately 1/16 inch The TYCO Series TY-B, 5.6 K-factor, (1,6 mm) for the 135°F (57°C) to 3/32 Upright(TY315)and Pendent(TY325) inch (2,4 mm) for the 360°F (182°C) si��,�� Sprinklers are intended for fire protec- temperature ratings. tion systems designed in accordance with the standard installation rules A leak-tight 1/2 inch NPT sprinkler recognized by the applicable Listing joint should be obtained by applying a or Approval agency (e.g., UL Listing minimum-to-maximum torque of 7 to 14 `- is based on the requirements of NFPA ft.-lbs. (9,5 to 19,0 Nm). Higher levels .."�, 13, and FM Approval is based on the of torque may distort the sprinkler inlet PUSH WRENCH requirements of the FM Loss Preven- and cause leakage or impairment of the IN TO ENSURE tion Data Sheets). Only the Style 15 sprinkler. ENGAGEMENT or Style 20 Recessed Escutcheon, as Do not attempt to compensate for WITH SPRINKLER applicable, is to be used for recessed insufficient adjustment in the escutch- WRENCHING AREA pendent installations. eon plate by under-or over-tightening FIGURE 3 the sprinkler. Readjust the position of W-TYPE 7 RECESSED the sprinkler fitting to suit. SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP152 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8"DIA. y sprinkler fitting using only the W-Type (73,0 mm) — 6 Sprinkler Wrench (Figure 2). With reference to Figure 1,apply the W-Type 2-1/4"DIA. 6 Sprinkler Wrench to the wrench flats. FACE OF — (57,2 mm) — Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING 5/8"(15.9 mm) Recessed Pendent Sprinklers t \ _ - FLUSH The Series TY-B Recessed Pendent 3/815/16" 1 I l • Sprinklers must be installed in accor- (9,5±7,9 mm) 'v % } I s 1 dance with the following instructions. } / �� ++ Step A.After installing the Style 15 or MOUNTING 1/8` - Style 20 Mounting Plate,as applicable, SURFACE (3,2 mm) over the sprinkler threads and with --- --— pipe-thread sealant applied to the pipe CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) threads,hand-tighten the sprinkler into TY-B PLATE 3/4"(19,1 mm) the sprinkler fitting. Step B.Tighten the sprinkler into the FIGURE 4 sprinkler fitting using only the W-Type SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) 7 Recessed Wrench (-Type WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 Sprinkler 3).With reference to Figure 1,apply the RECESSED ESCUTCHEON W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque 2-7/8"DIA. sprinklers 7 to 14 ft.-Ibs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF - Step C.After the ceiling is installed or SPRINKLER ,_ 2-1/4"DIA. the finish coat is applied, slide on the FITTING (57,2 mm) Style 15 or Style 20 Closure over the 5/16±1/4" 1/2"(12,7 mm Series TY-B Sprinkler and push the (7,9±6,4 mm) ( mm) Closure over the Mounting Plate until j - FLUSH its flange contacts the ceiling. 1_ ^�=1 • , Care and t I /�� \ -_,, } MOUNTING , 1/8" Maintenance SURFACE - (3, J 2 mm) The TYCO Series TY-B, 5.6 K-factor, - i Upright(TY315)and Pendent(TY325) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-B PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) main control valve for maintenance WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. The owner is responsible for the system from the proper authorities Sprinklers that have been exposed to inspection,testing,and maintenance of and notify all personnel who may be corrosive products of combustion, but their fire protection system and devices affected by this action. have not operated,should be replaced in compliance with this document, as Absence of the outer piece of an if they cannot be completely cleaned by well as with the applicable standards escutcheon, which is used to cover wiping the sprinkler with a cloth or by of the National Fire Protection Associa- a clearance hole, can delay sprinkler brushing it with a soft bristle brush. tion (e.g., NFPA 25), in addition to the operation in a fire situation. Care must be exercised to avoid dam- standards of any other authorities hav- The owner must assure that the age to the sprinklers-before, during, ing jurisdiction. Contact the installing are not used for hanging and after installation.Sprinklers dam- sprinklers contractor or sprinkler manufacturer g g aged by dropping, striking, wrench regarding any questions. any objects and that the sprinklers are twist/slippage, or the like, must be Automatic sprinklers are recommended only cleaned by means of gently dust- replaced. Also, replace any sprinkler to be inspected,tested,and maintained ing with a feather duster; otherwise, that has a cracked bulb or that has lost by qualified Inspection Service in non-operation in the event of a fire or y a q p inadvertent operation may result. liquid from its bulb. (Ref. Installation accordance with local requirements Section.) and/or national codes. Sprinklers which are found to be leak- Thereafter, annual inspections per ing or exhibiting visible signs of corro- NFPA 25 are required;however,instead sion must be replaced. - of inspecting from the floor level, a Automatic sprinklers must never be random sampling of close-up visual painted, plated, coated, or otherwise inspections should be made. altered after leaving the factory. TFP152 Page 4 of 4 .i P/N* 77 - XXX - X - XXX I I SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2"NPT) TY315 1 NATURAL BRASS 135 135`F(57°C) PURE WHITE(RAL9010)" 571 5.6K PENDENT(1/2-NPT) TY325 3 POLYESTER 155 155°F(68°C) •Use suffix"I"for ISO 7-1 connection; SIGNAL WHITE(RAL9003) for example,77-570-4-175-I 4 POLYESTER 175 175`F(79°C) 9 CHROME PLATED 200 200°F(93°C) Eastern Hemisphere sales only 286 286'F(141`C) 360 360°F(182°C) 000 OPEN*** "'OPEN indicates sprinkler assembly without Glass Bulb, Button,and Sealing Assembly TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order,indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B Upright or Pen- dent(specify)Sprinkler, SIN (specify), K=5.6, Standard Response, (specify) temperature rating,(specify)finish,P/N (specify,refer to Table A) Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with(specify*)finish, P/N(specify*) Specify:Style 20 Recessed Escutcheon with(specify*)finish, P/N(specify") *Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 19446 Tele hone+1-215-362-0700 I Y, I P Copyright©2014 Tyco Fire Products,LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation. Fire Protection Products Worldwide . tqco Contacts www.tyco-fire.com Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall - Standard Response, Standard Coverage General The owner is responsible for main- taining their fire protection system and ,-- °" Descry t/on devices in proper operating condition. r' p The installing contractor or sprinkler TYCO Series DS-1 Dry Type Sprinklers, manufacturer should be contacted with 5.6K Pendent,Upright,and Horizontal any questions. Sidewall, Standard Response (5 mm Series DS-1 Dry-Type Sprinklers must r Bulb) and Standard Coverage, are only be installed in fittings that meet F. decorative glass bulb automatic sprin- the requirements of the Design Criteria ) klers typically used where: section. ' • pendent sprinklers are required on a dry pipe systems that are exposed to Sprinkler ti freezing temperatures; for example, sprinkler drops from unheated Identification - portions of buildings • sprinklers and/or a portion of the Numbers (SiNs) connecting piping may be exposed to �'frp zing temperatures; for example, TY3255-Pendent 0 •sprinkler dro ps from wet systems TY3255-Upright ht -b into freezers, sprinkler sprigs from TY3355-Horizontal Sidewall wet systems into unheated attics, or N' horizontal piping extensions through Technical a wall to protect unheated areas of a building such as loading docks,over- Data hangs,and building exteriors Physical Characteristics • sprinklers are used on systems that Approvals Inlet Copper are seasonably drained to avoid UL and C-UL Listed Yoke Stainless Steel freezing;for example,vacation resort FM Approved 9 P Casing Galvanized LP areas CB Approved: Ref No.094a/11 CE Certified,Certificate of Conformity: Carbo Steel 0832-CPD-2015 Insert Seat Stainless Steel ert B Bronze Bu NOTICE NYC Approved under MEA 352-01-E Series DS-1 Dry-Type Sprinklers Bulb Glass R described herein must be installed Refer to Table A. Compression Screw Bronze and maintained in compliance with this Working Deflector Bronze document, as well as with the appli- Maximum Pressure Frame Bronze cable standards of the National Fire 175 psi(12,1 bar Guide Tube Stainless Steel Water Tube Stainless Steel Protection Association, in addition to Inlet Thread Connections Spring Stainless Steel . the standards of any other authorities 1 Inch NPT(Standard Order) Sealing Assembly. . . Beryllium Nickel having jurisdiction. Failure to do so ISO 7-R1 w/TEFLON may impair the performance of these Escutcheon Carbon Steel devices. Discharge Coefficient K=5.6 GPM/psi112 IMPORTANT (80,6 LPM/bar1I2) Always refer to Technical Data Temperature Ratings Sheet TFP700 for the `INSTALLER Refer to Table A. WARNING"that provides cautions - with respect to handling and instal- Finishes lation of sprinkler systems and Sprinkler: Natural Brass, Chrome components. Improper handling and Plated,Signal White installation can permanently damage Escutcheon: Signal White, Chrome - a sprinkler system or its compo- Plated,Brass Plated nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 JUNE 2013 TFP500 TFP500 Page 2of8 TY3255 Pendent TY3255 Pendent TY3355 Horizontal Sidewall li with top of Deflector-to-Ceiling with Standard with Standard Escutcheon distance of 4 to 12 inches Recessed Escutcheon (Figure 3) (100 to 300 mm) (Figure 4) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon Temperature R Rating Bulb Color (Figure 6) (Figure 9) t n 9 - TY3155 Upright without Escutcheon (Figure 10) without Escutcheon (Figure 7) SPRINKLER FINISH Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F(57°C) Orange 155°F(68°C) Red 1,2,3,5 1,2,5 175°F(79°C) Yellow 1,2,3,4,5 1,2,4,5 1°,2',3",4,5 1',2*,4,5 200°F(93°C) Green 286°F(141°C) Blue 1,2 360°F(182°C) Mauve N/A 1,2,3 1,2 1",2",5 1",2" - Notes 4. Loss Prevention Certification Board and CE conformity apply to these 1. Listed by Underwriters Laboratories,Inc.(maximum order length of 48 temperature ratings only inches) 5. Approved by the City of New York under MEA 352-01-E 2. Listed by Underwriters Laboratories for use in Canada(maximum order • Light and Ordinary Hazard Occupancies Only length of 48 inches) "" Light Hazard Occupancies Only 3. Approved by Factory Mutual Research Corporation(maximum order WA-Not Available length of 48 inches) TABLE A SERIES DS-1 STANDARD RESPONSE,STANDARD COVERAGE,DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS PLUG WITH PI 9 INLET SEALING .1"=°='';+�.; Y ASSEMBLY ; WRENCH i i YOKE RECESS SPRING ill�� $,00!0 i±s .t1 INLET 1s; BAND 1 .... 1 WATER % WRENCH ■ O TUBE ;ibikill 1 CASING FLAT ■ ■ GUIDE ;!'S ■ INSERT PUSH WRENCH TUBE ; .— Ili IN TO ENSURE ENGAGEMENT �� ` BULB WITH SPRINKLER FRAME i/1 ,i SEAT WRENCHING AREA trPf FIGURE 2 j f 5 mm BULB W-TYPE 7 VENT HOLE I �•ii SPRINKLER WRENCH jij DEFLECTOR .F COMPRESSION SCREW FIGURE 1 - SERIES DS-1 STANDARD RESPONSE DRY-TYPE SPRINKLERS ASSEMBLY A TFP500 Page 3 of 8 SPRINKLER FITTING SPRINKLER FITTING SPRINKLER FITTING NI (REFER TO DESIGN (REFER TO DESIGN (REFER TO DESIGN CRITERIA SECTION) CRITERIA SECTION) CRITERIA SECTION) FACE OF FACE OF FACE OF SPRINKLER SPRINKLER SPRINKLER FITTING FITTING - ., FITTING L_ _J L_ _J �� L_ _J I I. ORDER LENGTHS: ORDER LENGTHS: ORDER LENGTHS: 3-1/2"DIA. 2-3/4"to 48" 1-3/4"DIA. 3-3/4"to 48" 1/2"to 46" x(88,9 mm)-' (69,9 to 1219,2 mm) (44,5 mm) (95,3 to 1219,2 mm) (12,7 to 1168,4 mm) IN 1/4"(6,4 mm) IN 1/4'(6,4 mm) 2-1/4"DIA. IN 1/4"(6,4 mm) 2-1/2"DIA. INCREMENTS I INCREMENTS (57,2 mm) INCREMENTS i_.(63,5 mm) 1 j ■_1 % FACE OF T I � ■ ■! FACE OF _U CEILING — FACE OF CEILING rill 1 I %�,;■r% CEILING km/ km/ 4-1/4"t 1/8' 111 I 3"DIA. (108,0 t 3,2 mm) � � 2-3/16'±1/8' 76,2 mm) 1 3/8"t 1/8" 2-7/8"DIA. (55,6 t 3,2 mm) (76,2 mm)m)(34,9 t 3,2 mm) _ V FIGURE 4 FIGURE 3 PENDENT(TY3255) FIGURE 5 PENDENT(TY3255) WITH STANDARD PENDENT(TY3255) WITH STANDARD ESCUTCHEON RECESSED ESCUTCHEON WITH DEEP ESCUTCHEON SPRINKLER FITTING I (REFER TO DESIGN TOP OF CRITERIA SECTION) DEFLECTOR FACE OF SPRINKLER FITTING ORDER LENGTHS: I 5'to 48", (1270 to 1219,2 mm) ORDER LENGTHS: IN 1/4'(6,4 mm) 5'to 48' INCREMENTS (127,0 to 1219,2 mm) IN 1/4'(6,4 mm) INCREMENTS FACE SPRINKLOF ER FITTING MINIMUM \ r- -, 1-3/4"(44,5 mm) DEFLECTOR TO CEILING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 6 FIGURE 7 PENDENT(TY3255) UPRIGHT(TY3155) WITHOUT ESCUTCHEON WITHOUT ESCUTCHEON TFP300 Page 4 of 8 ORDER LENGTHS: Operation tl 2-3/4"to 48"(69,9 to 1219,2 mm) IN 1/4'(6,4 mm)INCREMENTS When TYCO Series DS-1 Dry Type _ 1 _ _ 2-3/8"±1/8" Sprinklers are in service, water is (60,3±3,2 mm) prevented from entering the assembly FACE OF FACE OF by the Plug with Sealing Assembly — SPRINKLER MOUNTING— (Figure 1)in the Inlet of the Sprinkler. FITTING SURFACE The glass bulb contains a fluid that expands when exposed to heat.When the rated temperature is reached,the 'III fluid expands sufficiently to shatter �I�IIIIIIII IiI =.s (76,2 mm) the glass bulb, and the Bulb Seat is —\I 3.5° 1 I released. SPRINKLER FITTING 1-3/4'DIA. 4 The compressed Spring is then able (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16' to expand and push the Water Tube as CRITERIA SECTION) OF WATERWAY (7,9 mm) well as the Guide Tube outward.This FIGURE 8 action simultaneously pulls inward on the Yoke, withdrawing the Plug HORIZONTAL SIDEWALL(TY3355) with Sealing Assembly from the Inlet, WITH STANDARD ESCUTCHEON allowing the sprinkler to activate and flow water. ORDER LENGTHS: 1/2"to 45-3/4"(12,7 to 1162,1 mm) Design IN 1/4"(6,4 mm)INCREMENTS __ 4-1/4'±1/8" Criteria 2-1/2'DIA. FACE OF (108,0 t 3,2 mm) FACE OF (63,5 mm) MOUNTING TYCO Series DS-1 Dry Type Sprinklers SPRINKLER SURFACE are intended for use in fire sprinkler FITTING ` systems designed in accordance IT with the standard installation rules ` recognized by the applicable Listing -- _ 3-1/2"DIA. or Approval agency; for example, UL �I�,I�I'jI!IIIII�!I� dal�_ J (88,9 mm) Listing is based on NFPA 13 require- s___;,, 3.5' merits. For more information on `- LPCB Approval, contact TYCO Fire SPRINKLER FITTING Suppression&Building Products at the (REFER TO DESIGN CENTERLINE 5/16" following office: CRITERIA SECTION) OF WATERWAY (7,9 mm) Kopersteden 1 FIGURE 9 7547 TJ Enschede HORIZONTAL SIDEWALL(TY3355) The Netherlands WITH DEEP ESCUTCHEON Tel:+31-(0)53-428-4444 Fax:+31-(0)53-428-3377 ORDER LENGTHS: Sprinkler Fittings - 5-1/2"to 48"(139,7 to 1219,2 mm) — Install 1 Inch NPT Series DS-1 Dry Type IN 1/4"(6,4 mm)INCREMENTS MINIMUM Sprinklers are to be installed in the 1 2-1/4"(57,2 mm) Inch NPT outlet or run of the following --DEFLECTOR TO fittings: FACE OF —SPRINKLER MOUNTING • malleable or ductile iron threaded FITTING SURFACE tee fittings that meet the dimen- sional requirements of ANSI 816.3 (Class 150) til } • cast iron threaded tee fittings that f meet the dimensional requirements ,_;\ 3.5° 5/16" of ANSI B16.4(Class 125). SPRINKLER FITTING (7,9 mm) Do not install Series DS-1 Dry Type (REFER TO DESIGN CENTERLINE Sprinklers into elbow fittings.The Inlet CRITERIA SECTION) OF WATERWAY of the sprinkler can contact the interior FIGURE 10 of the elbow. HORIZONTTAL SIDEWALL(TY3355) The unused outlet of the threaded tee is - WITHOUT ESCUTCHEON plugged as shown in Figure 12. You can also install Series DS-1 Dry-Type Sprinklers in the 1 Inch - NPT outlet of a GRINNELL Figure 730 Mechanical Tee and GRINNELL TFP500 Page 5 of 8 Temperatures for Heated Areal Ambient Temperature Exposed to Discharge End of 40°F(4°C) I 50°F(10°C) I 60°F(16°C) Sprinkler Minimum Exposed Barrel Length, Inches(mm)2 40°F(4°C) 0 0 0 30°F(-1°C) 0 0 0 20`F(-7°C) 4(100) 0 0 10'F(-12°C) 8(200) 1 (25) 0 0°F(-18°C) 12(305) 3(75) 0 -10°F(-23°C) 14(355) 4(100) 1 (25) -20'F(-29°C) 14(355) 6(150) 3(75) -30`F(-34°C) 16(405) 8(200) 4(100) -40°F(-40°C) 18(455) 8(200) 4(100) -50°F(-46°C) 20(510) 10(255) 6(150) -60°F(-51'C) 20(510) 10(255) 6(150) Notes 1. For protected area temperatures that occur between values listed above,use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph(18,6 kph). TABLE B - EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS G-FIRE Figure 522. However, the use NOTICE For protected area temperatures of the Figure 730 Tee and Figure 522 for Do not install Series DS-1 Dry-Type between those given above, the this stamsngement is limited to wet pipe Sprinklers into any other type fitting the face f the itti g to theeo outside of Y without first consulting the Technical The configuration shown in Figure 13 Services Department.Failure to use the the protected area may the determined 9 g by interpolating between the indicated is only applicable for wet pipe systems appropriate fitting may result in one of values. where the sprinkler fitting and water- the following: filled pipe above the sprinkler fitting are •Failure of the sprinkler to operate prop- Clearance Space not subject to freezing and where the erly due to formation of ice over the In accordance with Section 8.4.9.2 length of the Dry-Type Sprinkler has the Inlet Plug or binding of the Inlet Plug of the 20.10 edition of NFPA 13,when minimum exposure length depicted in a connecting an area subject to freezing • engagement of the Inlet Figure 11.Refer to the Exposure Length 9 9 and an area containing a wet pipe section. pipe-threads with consequent leakage sprinkler system,the clearance space For wet pipe system installations of Drainage around the sprinkler barrel of Dry-Type 1 Inch NPT Series DS-1 Dry-Type In accordance with the minimum Sprineratu must be sealed. Due to Sprinklers connected to CPVC piping, requirements of the National Fire areas, help potential for between two use only the following TYCO CPVC Protection Association for dry pipe areas,condensation ationtinl for the sprinkler and of fittings: sprinkler systems, branch,cross,and subsequent seque t ice bin the increased.dad • feed-main piping connected to Dry subsequent ice build-up is increased.If 1" x 1" NPT Female Adapter (P/N this condensation is not controlled, ice 80145) Sprinklers and subject to freezing build-up can occur that might damage temperatures must be pitched for the dry-type sprinkler and/or prevent • 1" x 1" x 1" NPT Sprinkler Head proper drainage. . Adapter Tee(P/N 80249). proper operation in a fire situation. Exposure Length Use of the Model DSB-2 Dry Sprinkler For dry pipe system installations, use When using Dry Sprinklers in wet pipe Boot,described in technical data sheet only the side outlet of maximum 2-1/2- sprinkler systems to protect areas TFP591 and shown in Figures 14 and - inch reducing tee when locating Series subject to freezing temperatures, use 15,can provide the recommended seal. DS-1 Dry-Type Sprinklers directly Table B to determine a sprinkler's below the branch line.Otherwise, use appropriate exposed barrel length the configuration shown in Figure 12 to to prevent water from freezing in the assure complete water drainage from connecting pipes due to conduction. above Series DS-1 Dry Type Sprinklers The exposed barrel length measure- - and the branch line. Failure to do so ment must be taken from the face of - may result in pipe freezing and water the sprinkler fitting to the surface of the damage. structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. TFP500 Page 6 of 8 y 11211 _ _ RUN—FACE OF / OUTLET TO WET SIDE SPRINKLER J O ` fPLUGGED SYSTEM OUTLET FITTING m HEATED EXPOSURE (SEE DESIGN SPRINKLER PLUGGED TO DRY FITTING HEATED AREA LENGTH SYSTEM CRITERIA AREA (SEE DESIGN SECTION) DSB-2 CRITERIA AREA D3B-2 SPRINKLER INTENDED SECTION) SUBJECT DSB-2 INTENDED FITTING FOR FREEZER TO INTENDED FOR FREEZER (SEE DESIGN STRUCTURES FREEZING FOR FREEZER STRUCTURES CRITERIA . A STRUCTURES SECTION) rd 11-I rdm 7717 7717 4. ,...., ...... FIGURE 12 FIGURE 13 FIGURE 11 SPRINKLER FITTING SPRINKLER FITTING EXPOSURE LENGTH UNHEATED AREA HEATED AREA STRAP TIES 1-3/4"DIA. (ENDS ON (44,5 mm) OPPOSING CLEARANCE INSULATED SIDES OF HOLE FREEZER BOOT) ADHESIVE STRUCTURE - DSB-2 BOOT DSB-2 rill"; ADHESIVE BOOT 1(1_4-34/,4"DIA. - , 5 mm) I III•CEARANCE HOLE i $INSULA TED i FREEZER_ I■, STRUCTURE STRAP DS-1 (ENDS ON SHOWN WITH liii SHOWN WITH OPPOSING STANDARD STANDARD SIDES OF ESCUTCHEON ESCUTCHEON BOOT) FIGURE 14 FIGURE 15 MODEL DSB-2 DRY SPRINKLER MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER DS-1 DRY-TYPE SPRINKLER TFP500 Page 7 of 8 Installation Note: If sprinkler removal becomes Care must be exercised to avoid necessary,remove the sprinkler using damage to the sprinklers - before, TYCO Series DS-1 Dry-Type Sprinklers the same wrenching method noted during,and after installation.Sprinklers must be installed in accordance with above.Sprinkler removal is easier when damaged by dropping,striking,wrench this section. a non-hardening sealant was used twist/slippage, or the like, must be and torque guidelines were followed. replaced. Also, replace any sprinkler General Instructions After removal, inspect the sprinkler for that has a cracked bulb or that has lost Series DS-1 Dry-Type Sprinklers must damage. liquid from its bulb. (Ref. Installation only be installed in fittings that meet Step 4. After installing the ceiling or Section.) the requirements of the Design Criteria wall and applying a ceiling finish, slide The owner is responsible for the section. Refer to the Design Criteria on the outer piece of the Escutcheon inspection, testing, and mainte- section for other important require- until it comes in contact with the nance of their fire protection system ments regarding piping design and ceiling/wall.Do not lift the ceiling panel and devices in compliance with this sealing of the clearance space around out of its normal position. document, as well as with the appli- the Sprinkler Casing. cable standards of the National Fire Do not install any bulb type sprinkler if When using the Deep Escutcheon, Protection Association (e.g., NFPA hold the outer piece in contact with the the bulb is cracked or there is a loss of mounting surface(ceiling or wall).Then 25), in addition to the standards of any liquid from the bulb.With the sprinkler rotate the inner piece approximately other authorities having jurisdiction.The held horizontally, a small air bubble 1/4 turn respect to the outer piece, installing contractor or sprinkler menu- with be present.The diameter of the facturer should be contacted relative to air bubble is approximately 1/16 inch to hold the Deep Escutcheon firmly any questions. (1,6 mm)for the 135°F(57°C)rating to together. 1/8 inch(3,2 mm)for the 360°F(182°C) Automatic sprinkler systems are recom- rating. Care and mended to be inspected, tested, and maintained by a qualified Inspection A leak-tight 1 Inch NPT sprinkler Maintenance Service in accordance with local joint should be obtained by applying requirements and/or national codes. a minimum-to-maximum torque of TYCO Series DS-1 Dry-Type Sprinklers 20 to 30 ft.-lbs. (26,8 to 40,2 Nm). must be maintained and serviced in Higher levels of torque may distort the accordance with this section. sprinkler Inlet with consequent leakage or impairment of the sprinkler. Before closing a fire protection system Do not attempt to compensate main control valve for maintenance for insufficient atte adjustment in an work on the fire protection system that it controls, obtain permission to Escutcheon Plate by under or ov er-an tightening the Sprinkler.Re-adjust the shut down the the proper fire authorities position of the sprinkler fitting to suit. systems from the proper authoritibe and notify all personnel who may be Step 1. Install pendent sprinklers only affected by this action. in the pendent position; install upright Absence of the outer piece of an sprinklers only in the upright position. escutcheon, which is used to cover a The deflector of a pendent or upright clearance hole, may delay the time to sprinkler is to be parallel to the ceiling. sprinkler operation in a fire situation. Install horizontal sidewall sprinklers in A Vent Hole is provided in the Bulb Seat the horizontal position with their center- (Figure 1)to indicate if the Dry Sprinkler line of waterway perpendicular to the back wall and parallel to the ceiling. is remaining dry. Evidence of leakage Ensure the word"TOP"on the Deflector from the Vent Hole indicates potential faces the ceiling. leakage past the Inlet seal and the need to remove the sprinkler to determine Step 2. With a non-hardening pipe- the cause of leakage; for example, an thread sealant such as TEFLON applied improper installation or an ice plug. to the Inlet threads, hand-tighten the Close the fire protection system control sprinkler into the sprinkler fitting. valve and drain the system before Step 3. Wrench-tighten the sprinkler removing the sprinkler. using either: Sprinklers which are found to be • a pipe wrench on the Inlet Band or leaking or exhibiting visible signs of the Casing(Figure 1). corrosion must be replaced. • the W-Type 7 Sprinkler Wrench on Automatic sprinklers must never be the Wrench Flat(Figure 2). painted, plated, coated, or otherwise altered after leaving the factory. Apply the Wrench Recess of the Modified sprinklers must be replaced. W-Type 7 Sprinkler Wrench to the Sprinklers that have been exposed to Wrench Flat. corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. TFP500 Page 8 of 8 ,t P/N* 60 - XXX - X - XXX - II I SIN SPRINKLER ESCUTCHEON to 96 Pendent with Standard TY3255 0 CHROME PLATED SIGNAL WHITE Escutcheon(1"NPT) (Figure 3) (RAL9003) 93 Pendent with Deep TY3255 1 NATURAL BRASS SIGNAL WHITE Escutcheon(1"NPT) (Figure 5) (RAL9003) 97 Pendent with Standard TY3255 2 NATURAL BRASS BRASS PLATED Recessed Escutcheon(1"NPT) (Figure 4) Pendent without TY3255 SIGNAL WHITE SIGNAL WHITE 92 Escutcheon(1"NPT) (Figure 6) 4 (RAL9003) (RAL9003) I 9 CHROME PLATED CHROME 94 Sidewall with Standard TY3355 Escutcheon(1"NPT) (Figure 8) 53 Sidewall with Deep TY3355 - Escutcheon(1"NPT) (Figure 9) 54 Sidewall without TY3355 Escutcheon(1'NPT) (Figure 10) TEMPERATURE ORDER _ I - RATING(2) LENGTH(3) 98 Upright without TY3155 0 135°F(57°C) 055 5.50" Escutcheon(1"NPT) (Figure 7) " Notes 1 155°F(68°C) 082 8.25" * Use Prefix "I" for ISO 7-R1 Connection; for example, 1-60-961-1-180. 2 175°F(79°C) 180 18.00" 1. Escutcheon applies to sprinklers provided with escutcheons. 3 200°F(93°C) 187 18.75" 2. 360°F(182°C)temperature rating applies to non-recessed sprinkler assemblies. 4 286°F(141°C) 372 37.25" 3. Dry-Type Sprinklers are furnished based upon "Order Length"as measured per Figures 3 through 10,as appli- 5 360°F(182°C) 480 48.00" cable, and for each individual sprinkler where it is to be installed.After the measurement is taken,round it to the nearest 1/4 inch increment. TABLE C SERIES DS-1 STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS PART NUMBER SELECTION Ordering • Deflector Style • Part Number from Table C. Part Upright, Pendent,and Horizontal numbers are for 1 Inch NPT standard Procedure Sidewall order sprinklers. Orders for all other • Order Length sprinkler assemblies must be accom- . Contact your local distributor for avail- Dry Type Sprinklers are furnished panied by a complete description. ability.When placing an order,indicate based upon Order Length as Sprinkler Wrench the full product name, including measured per Figures 3 through 10, Specify W-Type 7 Sprinkler Wrench, description and Part Number(P/N). as applicable.After the measurement P/N 56-850-4-001. Dry Sprinklers is taken, round it to the nearest 1/4 Y p inch increment. Sprinkler Boot When ordering 5.6 K-Factor Series DS-1, Standard Response , Standard • Inlet Connections Specify Model DSB-2 Dry ry Sprinkler Coverage (5 mm Bulb), Dry-Type 1 Inch NPT or ISO 7-R1 Boot,P/N 63-000-0-002. Automatic Sprinklers, specify the . Temperature Rating This Part Number includes one Boot, following information: two Strap Ties,and 1/3 oz.of Adhesive • SIN • Sprinkler Finish (a sufficient quantity for installing one Pendent TY3255,Upright TY3155,or • Escutcheon Style and Finish, as boot). - Horizontal Sidewall TY3355 applicable GLOBAL HEADQUARTERS 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright O 2013 Tyco Fire Products,LP. All rights reserved. tgco TEFLON is trademark of The DuPont Corporation. Dyna-Thread® - M-COAT® Submittal Data Sheet O Full Line Sch-40 Replacement Dyna-Thread—M-COAT Specifications Dyna-Thread"'—M-Coat`''sprinkler pipe represents an engineering NPs Nominal I.D. Wt. Wt.(H20 Filled) CRR CRR advancement for the sprinkler pipe industry.It combines the safety In;mm In;mm Lbs/FT kg/m LbslFt kg/m Unthreaded Threaded and longevity of traditional Sch-40 pipe with quality and superior 1" 1.080 1.330 1.75 11.39 1.00 hydraulic advantages. 25 27.4 2.0 2.60 — — 11/4" 1.408 1.870 2.54 9.50 1.00 O Comparison to Schedule 40 32 35.8 2.8 3.78 — — 1'h" 1.639 2.290 3.22 9.14 1.00 Dyna-Thread'—M-Coat inside diameter is up to 3.6%larger than Sch-40 40 41.6 3.4 4.79 — — giving it superior hydraulics.Also,when used in combination with Dyna- 2" 2.104 3.050 4.57 8.41 1.00 Flow—M-Coat pipe,down sizing often occurs.Dyna-Thread is fully listed and 50 53.4 4.5 6.80 — — approved UL, ULC,and FM for fire sprinkler applications.The life expectancy of Dyna-Thread—M-Coat and Sch-40 are equal based on the calculated wall ® c 0 thicknesses per UL.The consistent quality of steel used to make Dyna-Thread— ,,,,,Vt0 M-Coat facilitates smooth threading and lower maintenance costs.The exterior of Dyna-Thread—M-Coat is protected by a clean,durable mill coating for ® American Made . extended shelf life and easy paint application.With its increased strength Manufactured at one of 3 U.S.Facilities and is available and lighter weight, Dyna-Thread—M-Coat reduces installation fatigue and through distributors in the USA,Canada,Mexico,and is ideal for retro-fit applications.Corrosion Resistance Ratio(CRR)is a UL Latin America. (Underwriters Laboratory)term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed O Specifications & Approvals thread,assumed to be the weakest point of the pipe length.Dyna-Thread— M-Coat and Sch-40 have the same calculated wall thicknesses at this point Dyna-Thread—M-Coat pipe is manufactured to meet:ASTM A and are both assigned the same CRR of 1.00. 135,Type E Grade A,and is in compliance with NFPA-13.All sizes of Dyna-Thread—M-Coat are rated at 300 psi working O Comparison to L.W.T. Pipe pressure.Dyna-Thread—M-Coat is UL and ULC Listed for wet, More wall thickness at the thread(CRR=1.00)gives Dyna-Thread—M-Coat dry and pre action sprinkler systems and FM Approved for better life expectancy than lightwall threadable pipe joints.Dyna-Thread— use in wet systems.Dyna Thread—M-Coat is approved for all M-Coat is approved for standard hanger spacing(15 ft.O.C.),can be used as threaded couplings and welded outlets and is suitable for all earthquake sway bracing,and is safe to use as drops.Dyna-Thread—M-Coat roll grooved,and plain end fittings.(See listing information). is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread—M-Coat is more widely accepted than lightwall threadable where Sch-40 is specified. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: clued�TJ ,_ ` d Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com �1/ 16100 S Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 A'Mi Of _ „ •, 02013 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1301 Dyna-Flow® - M-COAT® Submittal Data Sheet O High Strength Steel Pipe Dyna-Flow-M-COAT Specifications Dyne-Flow)-M-Coat'pipe is the"original"high-strength li htwall s sprinkler pipe. NPS Nominal I.D. Wt. Wt.(1120 Filled) CRR Y P�P 9 9 P k P�P Dyna-Flow-M-Coat has outstanding hydraulic capabilities and is recognized as the In;mm In;mm Lbs/Ft;kg/m Lbs/Ft;kg/m Unthreaded most popular alternative to Schedule-10 pipe.Lightweight,easy to cut and easy to 1" 1.191 0.830 1.31 2.41 handle for installation.Dyna-Flow-M-Coat is a valuable addition to any fire 25 30.3 1.2 1.95 - protection system. 1¼" 1.536 1.059 1.87 1.55 32 39.0 1.6 2.78 ® Additional Benefits 11" 1.728 1.667 2.71 3.44 Lightweight and easy to install,resulting in more efficient use of your freight and labor 40 43.9 2.5 4.03 - dollars.Provides stability needed to comply with standard hanger spacing(15 ft 0.C.) 2" 2.203 2.104 3.79 2.78 per NFPA.Available in standard lengths for your convenience,or can be ordered in 50 56.0 3.1 5.64 - custom lengths upon approval.Fast cutting and welding,as well as easy roll grooving 21/2" 2.703 2.564 5.10 1.60 and end preparation.Available in Factory roll grooved form for quicker shop turnaround. 65 68.7 3.8 7.59 - _ _ Clean,durable mill coating provides longer"shelf life"and acts as an excellent primer 3" 3.314 3.387 7.18 1.48 for custom paint applications. 75 84.2 5.0 10.69 - 4" 4.310 4.473 10.86 1.00 pO Superior Hydraulics With an inside diameter of up to 11%larger than Schedule 40 and up to 7%larger ® ,® 4:, than Schedulel0,Dyna-Flow-M-Coat pipe hydraulics are exceptional.Larger I.D.s APPROVED enable Dyna-Flow-M-Coat,and related components,to be down-sized within the system,thus increasing the potential for job cost savings.For complete Hazen-Williams p Specifications & Approvals charts,refer to"Dyna-Flow Hydraulic Data Tables." Dyna-Flow-M-Coat pipe is manufactured to meet ASTM A 795, ® Coatings & Fabrication Type E Grade A,and are in compliance with NFPA-13 and NFPA-14. Dyna-Flow-M-Coat products are coated externally with an environmentally approved All sizes of Dyna Flow are UL Listed,FM Approved and ULC Listed. and specially formulated modified-acrylic or water-based coating.This durable,exterior Dyna-Flow-M-Coat is UUULC Listed for use with roll grooved, black coating is paintable and acts as an excellent primer that is resistant to weathering plain-end couplings,and welded joints for wet,dry,pre-action and and U.V.degradation from outdoor storage.Metallurgical properties provide excellent deluge systems.It is FM Approved for roll grooved,plain-ended,and fabrication characteristics for end prep finishes,welding arid roll grooving.No special welded joints for wet systems.Refer to appropriate documentation process or equipment is needed for fabrication and installation. for up-to-date listing and approval information. The internal surface of all black Fire Sprinkler pipe up to 4.5000"in diameter shall be coated with Allied Tube&Conduit's"M-Coat"ID Coating. O American Made . Manufactured at one of 3 U.S.Facilities and is available through distributors in the USA, Canada,Mexico,and Latin America. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: n);allied Customer Service:(800)882-5543 Fax:(800)659-7730 www.alliedtube-sprinkler.com 16100 5 Lathrop Ave • 11350 Norcom Rd. • 2525 N 27th Ave. TUBE&CONDUIT' Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 "'"q."AdtkOre ©2012 Atkore International,Inc.All Rights Reserved.STP-S3-4M-1207 SMTHCOOPER® I N T E R N A T I O N A L Ductile Iron Threaded Fittings Specifications ... .. .. ........... • © branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 C US LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 3,. 420 400 400 450 380 AMINE 500 360 550 340 600 320 >..,w, .�...�,.>. 650 300 /`-,, .., ti ' Ductile Iron Fittings-Class 300 UL/FM ri p.i.rrr?LIE C ® US • APPROVED Fig. 35E 3-90°Elbow LISTED A Size A Packing Weight ri��.� in Part Number in Inner Master lb I� _••���. 1/2 35E 3004 1.13 100 200 0.2 �� 3/4 35E 3006 1.31 70 140 0.3 ��-••,i I ,) A 1 35E 3010 1.50 40 80 0.5 • `'�!i 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3-90°Reducing Elbow B � Size Part Number A B Packing Weight in in in Inner Master lb I/, 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 / 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 _ .,,,,. _ JA 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 "' 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 D 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 U 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 C 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 T I Fig. 35F 3-45°Elbow ESize Part Number A Packing Weight �A in in Inner Master lb , 1/2 35F 3004 0.88 150 300 0.2 4.4 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 ,�ti� At 1-1/4 35F 3012 1.29 25 50 0.7 1 �A 1-1/2 35F 3014 1.44 20 40 1.0 %//- 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight in in Inner Master lb - A 1/2 35T 3004 1.13 80 160 0.3 • I�1I 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 A A 1-1/2 35T 3014 1.94 10 20 1.5 2 3513020 2.25 6 12 2.4 " 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL° • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcuuper.cum j.: II ucti e ron fittings - ass I I I / 7 r QUALITY?LEIS C � US V APPROVED Fig. 35RT3-Reducing Tee LISTED Size Part Number A B C Packing Weight jiplti i n in in in Inner Master fib C 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 a lir...'....*'`....iliti--�� -�-- 1 x 1/2 x 1 35RT301000401() 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 B A i 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 314 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35R13014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2 x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 D 1-1/2x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 U 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 C 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 T 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 L 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35R13020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2x 1-1/4 x 2 35R13020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 - 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2 x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee ) Size A B C Packing Weight --= L IC in Part Number in in _ in inner Master Ib • 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 . }p, sr+ 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 '' 1 x 1-1/2 35613010014 1.80 1.80 1.65 15 30 1.0 - e A---)I(----) 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35613012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 3561'3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcoupeccom 112 Ducts e ron 'thugs- ass I I 1 ' • I QUALIFY PLUS CID US * APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size Part Number A Packing Weight "" "--' in in Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1.---, ,,---' 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 • 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size A Packing Weight � in Part Number in Inner Master lb /- A 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x 3/4 35RC3010006 1.69 60 120 0.4 a1 1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1(not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb 1 x 1/2 35HB3010004 1.06 180 360 0.2 -r A 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 IN 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2 x 1-1/4 35HB3014012 1.25 75 150 0.3 D 2 x 1 35HB3020010 1.38 40 80 0.6 U 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 C 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 T I Fig. 35SP3 -Square Head Plug L E Size Part Number A Packing Weight in in Inner Master lb -N.-4w/fir:; �� 1/2 35SP3004 0.94 600 1200 0.07 A, IA 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 _-`= -40' 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 . Fig. 35U 3- Union with Brass Seat A Size A Packing Weight in Part Number in Inner Master lb (11''I 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 �Am� 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com • FireLock EZ® Rigid Coupling ✓4taulic Style 009N 10.64 • Material Specifications: Housing: * " , ' Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. PATENTED Housing Coating: Approvals/Listings: Orange enamel (North America, Asia Pacific) Red enamel (Europe) c us FM LPCB CM Optional: Hot dipped galvanized USTEI See Victaulic Publication 10.01 for more details. Gasket: Grade "E" EPDM (Type A) Product Description: — — FireLock EZ products have been Listed by Underwriters The FireLock EZ Style 009N Installation-ReadyT"" Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for Rigid Coupling is for use in the fire protection market. wet and dry(oil free air)sprinkler services within the rated The coupling's unique design eliminates loose parts, working pressure. promotes consistent installation and provides substantial gains in productivity. Bolts/Nuts: IMPORTANT Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and FireLock EZ Style 009N couplings are recommended for physical requirements of ASTM A-183. use ONLY on fire protection systems. Job/Owner Engineer System No. Spec Section Location , Paragraph Contractor Approved Submitted By Date Date • victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev F Updated 03/2014 ©2014 Victaulic Company.All rights reserved. 1 siCtauli victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 • Listings/Approvals 1 The information provided below is based on the latest listing and approval data at the time of publication. or Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. r - - I Nominal - --- Size — — cULus — -- . FM —- - 1 Vds vat Sch.5 Sch.10 Sch.40 Sch.5 Sch.10 Sch.40 Inches psi psi psi psi psi psi psi psi _ mm _ kPa kPa kPa kPa kPa kPa kPa _ kPa 134 232 i 365 365 175 363 363 365 r 365 32 1600 2517 2517 1205 2502 2502 2517 2517 _ 114 232 365 365 175 363 363 365 365 40 1600 2517 2517 1205 2502 2502 2517 -2517-_ 2 363 365 365 175 363 363 365 365 50 2502 — 2517 _ 2517 1205 2502 2502 2517 2517 21 N/A 365 365 175 363 363 365 365 65 2517 2517 1205 2502 2502 2517 2517 3652 32 76.1 mm N/A 2517 N/A N/A 2502 WA 2517 2517 3 WA 365 365 175 363 363 365 365 80 2517 - 2517 1205 2502 - 2502 2517 2517 4 365 365 175 363 363 365 365 100 N/A 2517 2517 _ 1205 _ 2502 _ 2502 _ 2517 _ 2517 _ 363 363 108.0 mm N/A N/A N/A N/A 2502 2502 N/A WA 5 290 365 363 363 125 WA 2000 2517 N/A 2502 2502 WA N/A 133.0 mm Refer to Submittal 10.61 a 139.7 mm Refer to Submittal 10.61 165.1 mm Refer to Submittal 10.61 6 290 365 363 363 150 N/A 2000 2517 N/A 2502 2502 N/A N/A a 290 365 363 363 200 WA 2000 2517 N/A 2502 2502 N/A N/A 1 Listed/Approved for wet and dry pipe systems(>—40°F/-40°C)for continuous use In freezing conditions,use of silicone gaskets is recommended. Please refer to the Victaulic Installation Manual(I-009N/009H)for details concerning when supplemental lubrication Is required. 2 cUlus listed for DIN 2458 2.6 mmm pipe wall. 3 FM approved for BS 1387 Medium 3.6 mm pipe wall. Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus FM cULus I FM Sch. Inches psi psi Sch. inches psi I psi Sch. inches psi psi kPa kPa L kPa kPa kPa kPa BLT 114—2 300 365 I EZT 11/s—2 300 I 365 1 Y4—2 300 365 . 2068 2517 2068 2517 2068 2517 DF 114—4 300 365 FF 114—4 300 365 MLT 114—2 N/A 365 2068 2517 j 2068 2517 2517 300 365 1 365 365 • DT 11/i-2 FLF 11-4 N/A ST 154-2 N/A 2068 2517 _ ___ � 2517 175 175 365 365 EF 1114-4 FLT 11/4-2 N/A STF 114-4 N/A 1206 i 1206 _+ 2517 _ 2517 300 365 365 365 14 EL 1 -2 FLTL 11/4-2 N/A 1 A TF 214-4 N/A 2068 2517 2517 2517 -i • ET40 1544—2 300 I 365 GL I 11/4—2 I 300 365 WLS � 114—2 300 ; 365 L 2068 j 2517 ; - 2068 - 2517 j i1 _ 2068 2517 • EZF 3—4 1 2068 ' 2517 17 1 MF 114—4 2068 7 WST 1 114—2 N/A 2517 XL r 154—2 300 365 2068 2517 10.64 7072 Rev F Updated 03/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 2 jotaulicr victaulic.com I Couplings I Rigid I Style 009N I Publication 10.64 • + Style 009N Dimensions: ii rzl tpi r� 10.:...1 r\� Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) . Dimensions Actual Maximum Maximum Allow. Pre-assebled t (Push On Condition) Joint Assembled Nominal Outside Working End Pipe End �� ' Weight • Size Diameter Pressure' Load' Separation2 Bolt/Nuta 1 i X Y X Y I Each inches Inches psi lbs. inches I (No.)size inches Inches Inches inches Inches lbs. mm mm kPa N mm inches mm mm mm mm mm kg 1% 1.660 365 790 0.10 2-1 x 2 3.10 4.90 2.70 4.90 1.92 1.4 32 42.4 2517 3514 2.54 M-10 x 2 79 124 69 124 49 0.7 11 1.900 365 1035 0.10 2-1 x 2 3.30 5.10 3.00 5.10 1.92 1.5 40 48.3 2517 4604 2.54 M-10 x 2 84 129 76 129 49 0.7 2 2.375 365 1616 0.12 2-1 x 2 3.90 5.60 3.50 5.60 1.95 1.9 50 603 2517 7193 3.05 M-10 x 2 99 142 89 142 50 0.9 21 2.875 365 2370 0.12 2-%x2½ 4.50 6.10 4.00 6.10 1.95 2.1 65 73.0 2517 10542 3.05 M-10 x 2Yz 114 155 102 155 50 1.0 761 mm 3.000 365 2580 0.12 2-a1/2r x 21 456 6.00 4.05 6.06 1.94 2.1 - 76.1 2517 11476 3.05 M-10 x 21/2 115.7 1525 102.8 153.9 49.2 1.0 3 3.500 365 3512 0.12 2-%x27 5.10 6.70 4.60 6.70 1.95 2.3 80 88.9 2517 15622 3.05 M-10x 21 129 170 117 170 50 1.0 4 4.500 365 5805 0.17 2-1/2 x 21/2 5.95 7.80 5.54 7.47 2.14 2.9 100 1143 2517 25822 4.32 M-10 x21/2 151 199 141 190 55 1.3 108.0 mm 4.250 365 5175 0.17 2- x 2 7h 556 739 5.28 736 2.14 3.1 •, 108.0 2517 23020 4.318 141 1.88 134 187 54 1.4 5 5.563 365 5178 0.17 7.19 9.25 6.7 9.11 2.19 5.0 125 1413 2000 23033 4.318 2-1/2 x 3 183 235 170 231 56 23 133.0 mm Refer to Submittal 10.61 139.7 mm Refer to Submittal 10.61 165.1 mm Refer to Submittal 10.61 6 6.625 365 9997 0.17 832 10.29 7.82 10.13 2.17 6.0 150 168.3 2000 44469 4.318 2-1/2x31/4 211 261 _ 199 257 55 2.7 8 8.625 365 13730 0.17 10.89 1331 10.22 13.1 2.5 11.4 4318 200 219.1 1620 61074 I 2-1x4 277 338 260 333 64 5.2 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Vlctaullc specifications.See page 1 of this document for Listed/Approved ratings on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be Increased to 1 1 times the figures shown In the chart on page 1,specific to pipe schedule and size. 2 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments. General Notes: NOTE:When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZ Style 009N couplings,use FireLock No.006 end caps containing the'EZ"marking on the inside face or No.60 end caps containing the"QV EZ" marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. Use Of Flushseal Gaskets For Dry Pipe Systems • NOTE:FireLock EZ couplings are supplied with FireLock EZ Grade"E"Type A gaskets.These gaskets include an Integral pipe stop,that once installed provides the similiar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. Installation Note Reference should always be made to the I-100 Victaulic Fluid inslalistan handbook for This product that be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are Included with each shipment of Victaulic to be instated in accordance with current Victaulic installation/assembly Instructions. products for complete installation and assembly data,and are available in PDF formal Victaulc reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty TradsmsMl Refer to the Warranty section of the current Price Lisl or contact Victaulic for details. Victaulic,FireLock EZ,and Installation-Ready are registered trademarks of Victaulic Company. 10.64 7072 Rev F Updated 03/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 3 uctauha Victaulic® Grooved End Fittings ✓ctaul�f� 07.01 Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved or No.20 Tee No. 10 Elbow with shoulders conforming to standard steel pipe outside • Certifications/Listings diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 ©■ 4►W LPCB Vic-Flange®adapters, check disc clearance dimensions with I.D. dimension of fitting. When supplied as"hot dip galvanized°the following fittings are UL Classified in accordance with ANSI/NSF 61 and for use on cold+86`F/+30°C potable water service and ANSI/NSF 372:No.10 90°Elbow,No.11 45°Elbow,No.12 22 1/2° Elbow,No.13 11 1/4°Elbow,No.100 90°Long Radius Elbow,No.110 45°Long Radius Elbow,No.20 Tee,No.25 Tee with Grooved Branch,No.30 45°Lateral, No.60 Cap,No.50 Concentric Reducers,No.51 Eccentric Reducers. Note:The following Victaulic fittings are VdS approved:No.10 90°Elbow,No.11 45°Elbow,No.20 Tee and No.60 Cap. Note:The following Victaulic fittings are LPCB approved:No.10 90°Elbow, No.11 45°Elbow,No.12 22 1/2°Elbow,No.13 11 1/4°Elbow,No.30 45°Lateral, No.30-R Reducing Lateral,No.100 Long Radius Elbow,No.110 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee,No.33 True Wye,No.50 Concentric Reducer,No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Product Description Victaulic offers a broad line of fittings in sizes through 60"/1500mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances.Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves or shoulders to permit fast installation without field preparation.The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to publication 14.04 for fittings available for plain end applications). Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Fittings I Grooved End I Publication 07.01 07.01 1449 Rev V Updated 05/2014 0 2014 Victaulic Company.All rights reserved. 1 ictaullic victaulic.com I Fittings I Grooved End I Publication 07.01 Material Specifications Fitting: (specify choice) Fitting Coating: (specify choice) Standard: Ductile iron conforming to ASTM A-536, Standard: Orange enamel. Grade 65-45-12. Optional: Hot dip galvanized and others. Some Optional: Segmentally welded steel as shown under fittings supplied electroplated as standard—see nipples product specifications. Nipples:(specify choice) Flanged Adapter Nipple Coating:(specify choice) 3/4—4"/20— 100 mm: Carbon steel, Schedule 40, Standard: None (Unfinished) conforming to ASTM A-53, Type F Optional: Orange enamel, hot dip galvanized and 5—6"/125— 150 mm: Carbon steel, Schedule 40, others. conforming to ASTM A-53,Type E or S, Gr. B 8—12"/2O0—300 mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53,Type E or S, Gr. B Flanged Adapter Nipples: (specify choice) Class 125 Flange: Cast iron conforming to ANSI B-16.1 Class 150 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Class 300 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face • 07.01 1449 Rev V Updated 05/2014 0 2014 Victaullc Company.All rights reserved. victaulic.com 3 ictaulid victaulic.com I Fittings I Grooved End I Publication 07.01 " Flow Data (Frictional Resistance) • The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given,for example, a 221°elbow is approximately one-half the resistance of a 45°elbow.Values of mid-sizes can be interpolated. I - Size 1 Dimensions I 90°Elbows 45°Elbows Tees No. 100 No. 110 I ' Actual Outside No. 10 1'/z D Long No. 11 1 Y2 D Long I Nominal Size I Diameter Std.Radius Radius Std.Radius j Radius Branch I Run inches inches feet feet feet feet feet feet a mm mm meters meters meters meters meters meters 1 1.315 1.7 _ 0.8 _ 4.2 1.7 25 33.7 0.5 0.2 1.3 0.5 _ 2 2.375 3.5 2.5 1.8 1.1 8.5 33 50 _ 60.3 1.1 0.8 05 0.3 2.6 1.1 76.1 mm 3.000 4.3 - - 2.1 - 10.8 4.3 _ 76.1 1.3 0.7 3.3 1.3 3 3300 5.0 3.8 2.6 1.6 13.0 5.0 80 88.9 1.5 1.2 0.8 05 4.0 13 108.0 mm 4.250 6.4 _ 32 _ 153 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 5.0 3.4 2.1 16.0 6.8 100 114.3 2.1 13 1.0 0.6 4.9 2.1 133.0 mm 5250 8.1 - 4.1 - 20.0 8.1 133.0 2.5 12 6.2 23 139.7 mm 5300 83 _ 4.2 - 21.0 8.5 139.7 2.6 1.3 6.4 2.6 5 5.563 8.5 _ 42 - 21.0 83 125 141.3 2.6 1.3 6.4 2.6 159.0 mm 6250 9.4 - 4.9 - 25.0 9.6 159.0 2.9 1.5 7.6 2.9 165.1 mm 6500 9.6 - 5.0 - 25.0 10.0 165.1 2.9 _ 13 7.6 3.0 6 6.625 10.0 7.5 5.0 3.0 25.0 10.0 150 168.3 3.0 2.3 13 0.9 7.6 3.0 8 8.625 13.0 9.8 6.5 4.0 33.0 13.0 200 219.1 4.0 3.0 _ 2.0 _ 1.2 10.1 _ 4.0 _ 10 10.750 17.0 12.0 83 5.0 41.0 17.0 250 273.0 5.2 3.7 2.5 15 12.5 5.2 12 12.750 20.0 143 10.0 6.0 50.0 20.0 300 323.9 6.1 _ 4.4 3.0 1.8 15.2 _ 6.1 14 14.000 24.5' 15.8 18.5' 11.0 70.0 23.0 350 355.6 7.5 4.8 5.6 3.4 213 7.0 16 16.000 28.0' 18.0 21.0' 13.0 80.0 27.0 400 406.4 8.5 53 6.4 4.0 24.4 8.2 18 18.000 31.0' 20.0 235' 14.0 90.0 30.0 _ 450 _ 457.0 9.5 _ 6.1 7.2 4.3 _ 27.4 9.1 20 20.000 34.0' 223 25.51 I 16.0 100.0 33.0 _ 800 508.0 10.4 6.9 7.8 4.9 303 10.1 24 24.000 42.0' 27.0 29.5' 19.0 120.0 40.0 600 - 610.0 12.8 - 8.2 9.0 5.8 36.6 12.2 AGS fittings available up to 60'71500 mm.Contact Victaulic for details. AGS' 1 Fitting flow data for 14-24"1350-600 mm size No.10 and No.11 Elbows Is based on fittings for Style 07 and 77 couplings.For flow data on AGS fittings(No.W10 and No.W11 Elbows),refer to publication 20.05. r 07.01 1449 Rev V Updated 05/2014 0 2014 Victaullc Company.All rights reserved. victaulic.com 4 .ctauliCr victaulic.com I Fittings I Grooved End I Publication 07.01 • Dimensions Elbows No. 10 90° Elbow No. 11 45° Elbow No. 12 22 1/2° Elbow No. 13 11 1/4° Elbow No. 100 90° Long Radius Elbow No. 101 90° Long Radius Elbow CtoE rCtoE Oh EtoE pi I 1 CtoE CtoE r.- p ��� Ct E I� C L o t-E CtoE No. 10 No.11 No.13 Nc. IMO No.110 Standard and GSNK No.100 No 110 No.10 No.11 No.12 No.13 90°long Radius 45°Long Radius Size 90°Elbow 45°Elbow 22Y2°Elbow 11' Elbow Elbow Elbow Actual Approx. Approx. Approx. Approx. Approx. Approx. Outside Wgt. Wgt Wgt. Wgt. Wgt. Wgt. Nominal Size Diameter C to E Each C to E Each C to E Each C to E Each C to E Each C to E Each inches inches inches lbs. inches lbs. inches lbs. inches lbs. inches lbs. inches lbs. mm mm mm kg mm kg mm kg mm kg mm kg mm kg 14 1.050 225 05 1.50 0.5 1.63(sw) 1.38(sw) _ 2.50(sw) 0.4 1.88(sw) 0.3 _ 20 26.9 57 0.2 38 02 41 - 35 64 0.2 48 0.1 1 1.315 225 0.6 1.75 0.6 3.252 0.6 1.38(sw) 03 2.88(sw) 0.6 2.25(sw) 03 25 33.7 57 03 44 0.3 83 0.3 35 0.1 73 03 57 0.2 1 14 1.660 2.75 1.0 1.75 0.9 1.75 0.8 138(sw) 0.5 3.25(sw) 1.1 238(sw) 0.7 32 42.4 70 03 44 0.4 44 0.4 35 0.2 83 03 60 0.3 1 Y2 1.900 2.75 1.2 1.75 0.9 1.75 0.8 1.38(sw) 0.5 3.63(sw) 2.2 2.50(sw) 13 40 48.3 70 03 44 0.4 44 0.4 35 02 92 1.0 64 0.6 2 2375 3.25 1.8 2.00 1.3 3.75 2 1A 1.38 1.0 438 2.5 2.75 1.8 50 60.3 83 0.8 51 0.6 95 0.6 35 0.5 111 1.1 70 0.8 2 1 2.875 3.75 3.2 2.25 22 4.002 2.3 130 1.1 5.13 3.4 3.00 2.8 65 73.0 95 1.5 57 1.0 102 1.0 38 03 130 13 76 1.3 76.1 mm 3.000 3.75 3.7 225 3.4 2.25 - 130 - - - - - 76.1 95 1.7 57 13 57 38 3 3.500 4.25 4.5 2.50 3.1 4502 3.1 130 2.1 5.88 6.0 3.38 4.9 80 88.9 108 2.0 64 1.4 114 1.4 38 1.0 149 2.7 86 2.2 3'1 4.000 450 5.6 2.75 4.3 2.50(sw) 4.0 1.75(sw) 2.7 90 101.6 114 2.5 70 2.0 64 1.8 44 1.2 4 4.500 5.00 7.1 3.00 5.6 2.88 5.6 1.75 3.6 7.50 123 4.00 73 100 1143 127 32 76 23 73 25 44 1.6 191 5.6 102 33 108.0 mm 4250 5.00 11.0 3.00 5.6 - - - - - - - _ 108.0 127 5.0 76 25 415 5.000 5.25(sw) 10.0 3.13(sw) 6.0 350(sw) 6.6 1.88(sw) 4.2 _ 120 1 127.0 133 4.5 79 2.7 89 3.0 48 1.9 5 5363 530 11.7 3.25 8.3 2.88(sw) 7.8 2.00(sw) 5.0 9.25(sw) 18.0 4.88(sw) 14.8 125 141.3 140 5.3 83 3.8 73 35 51 2.2 235 82 124 6.7 133.0 mm 5250 530 11.7 325 8.3 _ _ _ - _ _ _ _ 133.0 140 53 83 3.8 139.7 mm 5500 550 11.7 3.25 8.3 2.88 - 2.00 - - - - 139.7 140 5.3 83 I 3.8 73 51 I I 6 6.625 630 172 3.50 10.8 625 2 122 2.00 7.0 1 10.75 30.4 5.50 , 17.4 1 150 168.3 , 165 7.8 89 4.9 159 5.5 51 3.2 273 13.8 140 7.9 2 Gooseneck design,end-to-end dimension fittings in this size,contact your nearest Victaulic sales representative. 3 For 147350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings In this size, contact your nearest Vlctaulic sales representative. 4 Chinese standard sizes 07.01 1449 Rev V Updated 05/2014 0 2014 Victaullc Company.All rights reserved. victaulic.com 5 ictaukc victaulic.com I Fittings I Grooved End I Publication 07.01 Reducing Tee No. 25 Grooved Branch j-curl= -ctoe _ No. 29T Threaded Branch II .T IIII_c E.rr-E CtcE• to to I V I'TC ."C NO.25 No.297 to to ' No.29T _ I No.25 w/Thd. Size Std. Branch Approx. • No.25 No.29T - Weight No.29T Nominal Size ! C to E C to E i Each No.25 w/Thd. inches Inches inches lbs. Size Std. Branch Approx. _ _. _ mm mm mm kg Weight 4 4 314 5.00(sw) 5.00(sw) i 8.0 Nominal Size C to E C to E Each 100 x 100 x 20 127 127 j 3.6 inches Inches Inches lbs. 1 5.00 5.00 1 7.8 mm mm mm kg 25 127 127 35 1 1 314 225(sw) 2.25(sw) 1.0 1 14 5.00(sw) 5.00(sw) 9.6 25 x 25 x 20 57 57 0.5 32 127 127 4.4 1 Ye 114 1 2.75(sw) 2.75(sw) 1.3 1554 5.00 5.00 10.2 32 x 32 x 25 70 70 0.6 40 127 127 4.6 1/ 1/ 34 2.75(sw) 2.75(sw) 1.5 2 5.00 5.00 11.2 40 x 40 x 20 70 70 0.7 50 127 127 5.1 1 2.75(sw) 2.75(sw) 1.5 2 Y 5.00 5.00 11.4 25 70 70 0.7 65 127 127 5.2 1 14 2.75(sw) 2.75(sw) 1.7 3 5.00 5.00 11.6 32 70 70 0.8 80 127 127 5.3 2 2 / 3.25 3.25 2.5 5 5 1 550(sw) 550(sw) 14.0 50 x SO x 20 83 83 1.1 125 x 125 x 25 140 140 6.4 _ 1 3.25 3.25 2.7 1 Y3 550(sw) 550(sw) 14.3 25 83 83 12 40 140 140 6.5 1 1/4 3.25(sw) 3.25(sw) 1.8 2 550(sw) 550(sw) 14.5 32 83 83 0.8 50 140 140 6.6 1 K 3.25 3.25(sw) 3.0 2 Y 550 550(sw) 152 40 83 83 1.4 65 140 140 6.9 2/ 2 Y3 are 3.75(sw) 3.75(sw) 3.9 3 5.50 550(sw) 16.6 65 x 65 x 20 95 95 1.8 80 140 140 7.5 1 3.75 3.75(sw) 3.8 4 5.50 5.50(sw) 16.7 25 95 95 1.7 100 140 140 7.6 1 14 3.75 3.75 42 6 6 1 6.50(sw) 6.50(sw) 23.0 32 95 95 1.7 150 x 150 x 25 165 165 10.4 1 15 3.75 3.75 3.9 1 Y4 6.50(sw) 650(sw) 24.0 40 95 95 1.8 40 165 165 10.9 2 3.75 3.75(sw) 4.5 2 6.50 6.50 21.6 50 95 95 2.0 50 165 165 9.8 3 3 14 4.25(sw) 4.25(sw) 5.7 2 Y 6.50 6.50 21.4 80 x 80 x 20 108 108 2.6 65 165 165 11.7 1 4.25 4.25 6.1 3 650 650 26.5 25 108 108 2.8 80 165 165 12.0 114 4.25 4.25 8.0 4 6.50 6.50 25.0 32 108 108 3.6 100 165 165 11.3 1 14 4.25 4.25(sw) 6.5 5 650 6.50 23.2 . 40 108 108 2.9 125 165 165 10.5 2 425 4.25(sw) 6.2 614 6 Y: 3 6.50 630(sw) 24.0 50 108 108 2.8 165.1 x 165.1 x 80 165 165 10.9 2 Y 4.25 4.25(sw) 6.4 4 650 6.50(sw) 25.0 ' 65 108 108 2.9 _100 165 165 11.3_.- 8 For 14'/350 mm and larger roll grooved systems,Victaulic offers the 8 For 14/350 mm and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove Advanced Groove System(AGS).For pricing and availability of cut groove fittings In this size,contact your nearest Victaulic sales representative. fittings In this size,contact your nearest Victaulic sales representative. 9 Cast fitting available.Contact Victaulic for details. 9 Cast fitting available.Contact Victaulic for details. r 07.01 1449 Rev V Updated 05/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 10 3ctaulid • ® <> Els LPCB Cal Mechanical-T® Bolted Branch Outlets vnliro SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N • Victaulic Mechanical-T®Outlet provides a direct branch connection at any location a hole can ..+ . be cut in pipe.The hole is cut oversize to receive a"holefinder"locating collar which secures `. the outlet in position permanently.A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and t ' size,with the same or differing branch size connections.NOTE:Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet.Specify choice on order.Units are supplied painted with plated bolts.Galvanized hous- PATENTED ings are available,supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe.They may also be used on high density polyethylene or poly- butylene(HOPE)pipe.Pressure ratings on HDPE are dependent on the pipe rating.Contact Victaulic for ratings on other pipe.Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90°angle when permanently attached to the pipeline surface. Additionally,the Vic Tap Ile hole cutting tool,which allows for hole cutting capabilities on pressurized systems,utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit.See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating:Ductile iron conforming to ASTM A-536,grade 65-45-12,with orange enamel coating.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. • Optional:Hot dipped galvanized Gasket:(Specify choice•) • Grade"E"EPDM EPDM(Green color code).Temperature range—30°F to+230"F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services.UL Classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C.NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade'T'nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range.Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. *Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICtauhc REV_M . CARBON STEEL PIPE•HOLE CUT PRODUCTS 11.02 ■ Mechanical T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Mas.Work Approx. Sine No. Pressure° Dimensions Weight Each 11omImt SIT* 930 .:. . i T" Thd. Ger. w Y Z ' TM. link _ Inches or psi .0.13 Inches Inches Inches Inches Inches Inches Lbs. Lbs. Y Z mm 920N kPa -0.00 mm mm mm mm mm mm kg kg , ■ t �� 2 x K(a)° 426N 500 1.50 2.00 2.53 _ 1.61 5.35 2.75 3.1 _ r� I� ��i� 50 15 I 3450 38.1 51 64 41 136 70 1.5 r•t ^ s•r. \TGG11/ 'la(a)a 500 1.50 1.97 2.53 _ 1.61 5.35 2.75 3.1 _ �, 20 1 920N 3450 38.1 50 64 41 136 70 13 T �4 , 1(a)° 500 150 1.85 2.53 _ 1.61 5.35 2.75 3.0 ).'41, Mill 25 920N 3150 38.1 47 64 41 136 70 1.4 - 114(a)t°' 920N 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 GROOVED OUTLET 32 3450 443 52 70 76 41 136 76 1.7 15 11/2(a)to 920N 500 1.75 2.03 2.75 3.12 1.61 5.35 3.25 3.6 3.2 40 3450 445 52 70 79 41 136 83 1.7 1.5 . Y . . -Z� 21 x K(a)5° 02QP1 500 150 2.21 2.74 _ 1.82 5.64 2.75 3.0 - 65 15 3450 38.1 56 70 46 143 70 1.4 ' 14(a)S° 920N 500 t S0 2.18 2.74 _ 1.82 5.64 , 2,75 3.0 _ vI riis �� oil T N r-1 1 20 3450 38.1 55 ' 70 46 143 70 i 1.4 i y 1�1 (a)§11 0 500 1.50 2.06 2.74 _ 1.82 5.64 2.75 2.9 _ M A `I/ 25 20N 3450 38.1 52 70 46 143 I 70 1.4 ^' 1114 t(a)a 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 + V l 32 920N 3450 445 58 76 83 46 160 76 1.7 1.5 FEMALE THREADED OUTLET 116 11a)n 920N 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 1/2(a) 300 130 2.22 2.75 _ 2.25 6.46 3.18 3.9 - 76.1 x 15 920N 2065 38.1 56 70 57 164 81 1.8 - • Provides a direct branch connection at (a) 300 1.50 2.19 2.75 _ 225 6.46 3.18 3.9 _ any location where a hole can be cut 20 920N 2065 38.1 56 70 57 164 81 1.8 in the pipe 1(a) 920N 300 130 2.07 2.75 _ 2.25 6.46 3.18 3.8 _ 25 2065 38.1 53 . 70 57 16_4 81 1.7 • A pressure responsive gasket provides 114(a)o 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 • 3.5 3.2 the seal 32 3450 445 58 76 84 49 160 76 1.6 15 134(a)n 920N 500 2.00 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 • Request Publication 11.03 for 40 3450 50.8 58 76 84 49 160 83 1.6 15 Mechanical-T cross assemblies 3 x 14(a)° 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 ; 3.4 80 15 3450 38.1 64 78 - 58 , 156 70 . 1.6 • Pressure rated up to 500 psi/3450 kPa M(a)° 920N 500 150 2.49 3.05 2.28 6.15 2.75 3.4 On steel pipe;also available for use 20 3450 38.1 63 78 - sa 1 156 70 1.6 with HDPE pipe 1(a 920N 500 150 2.38 3.06 - 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 • Sizes from 2 x 1/2"/50 x 15 mm 11G(a)to 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 ; 3.8 3.7 through 8 x 47200 x 100 mm 32(b) 3450 445 65 83 90 58 156 76 1.8 1.8 1 1 6(a)t°I 500 2.00 2.78 3.50 356 2.28 ' 6.15 3.25 4.1 3.8 40(b) 1920N 3450 50.8 71 89 90 58 156 83 1.9 1.8 2(a)° 920N 500 2.50 2.75 3.50 356 2.28 6.75 3.88 4.9 4.6 50 3450 63.5 70 89 90 58 172 99 2.3 2.1 31 x 2 ' 920N 500 230 3.00 3.75 2.44 6.72 3.88 3.8 90 50 3450 635 76 - 95 62 171 99 1.8 IMPORTANT NOTES: TABLE CONTINUED ON PG.3 Style 920 and Style 920N housings cannot be ""Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). mated to one another t Available with grooved or female threaded outlet Specify choice on order. to achieve cross connections. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify'BSPT'clearly on order. (b)For 76.1 mm threaded outlet,specify 2W BSPT clearly on order. §Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. • www.victaulic.com jctaul IC vICTAULIC IS A REGISTERED TRADEMARK Of VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 11.02_2 CARBON STEEL PIPE-HOLE CUT PRODUCTS 11 .02 Mechanical T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Approx. Size No. "ressuree Dimensii r. Weight Each r z nld Cry __ =-I - mums 920N psi -0.00 Inches Inches Inches Inches Inches Inches Lbs. Lbs. • - ' • mm 92014 kPa -0.00 mm mm mm mm mm mm kg kg 4 TABLE CONTINUED PROM PAGE 2 .....14 r �► 4 x 15(a)• 1 92014 500 130 3.03 3.56 2.69 7.01 2.75 3.7 - Its ''-� r7r, =TV 100 15 I 3450 38.1 77 90 - 68 178 70 1.8 .wiiire if(a)d 500 15G 3.GG 336 2.69 7.01 2.75 3.7 - II ` 20 920N $450 38.1 76 90 - 68 178 70 1.8 -- 1 wI 1(g)° 1 920N 500 1.50 2.88 3.56 2.69 7.01 2.75 3.6 25_I 3450 38.1 73 90 68 178 70 1.8 - GROOVED OUTLET 11/4(a)to 92GN 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 11/2(a) 920N 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 42 3.9 y t z r 40(b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2(a)tII 92014 500 2.50 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 �'� 50 3450 63.5 83 102 102 68 178 99 2.3 2.1 jr .in • 'Ili 1 216(a)t 500 2.75 2.88 4.00 ' 4.00 2.69 7.34 4.63 5.8 5.0 T r•� / 65 920 3450 69.9 73 102 102' 68 186 118 2.6 2.3 1 + �1 W _ 761 mm 920 3 50 69.9 73 - I 102 68 186 ' 4.63 18 - 2.9 lyl 3(a)t 500 350 3.31 4.50 4.12 2.69 . 7.73 5.12 8.4 6.4 ' 80 920 3450 88.9 84 114 105 68 196 130 3.8 ' 2.9 FEMALE THREADED OUTLET 114(a)la 500 1.75 3.08 3.78 2.63 7.64 3.05 5.0 108k x 32 l 920N 3450 44.5 78 96 - 67 194 78 2.3 - 114(a)n 92014 500 2.00 3.28 4.00 - 2.63 7.64 3.25 5.0 - • Provides a direct branch connection at 40 3450 50.8 83 102 67 194 83 23 any location where a hole can be cut 2(a) 500 250 3.25 4.00 _ 2.63 7.64 4.00 4.0 _ in the pipe 50 920N 3450 63.5 83 102 67 194 102 1.9 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 • A pressure responsive gasket provides 3450 69.9 73 102 102 67 194 109 3.6 35 the seal 3(a) 920 500 350 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 3450 88.9 84 114 114 67 194 124 3.1 3.0 • Request Publication 11.03 for 5 114(a)t o 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 Mechanical-T cross assemblies 125 ' 40 20 3450 50.8 102 121 121 80 246 94 3A 3.4 2(a)t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 • Pressure rated up to 500 psi/3450kPa sG 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 on steel pipe;also available for use 216(a)t 920 500 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 with HDPE pipe 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 761 mm 920 500 2.75 3.75 - 4.75 3.16 9.70 4.63 - 8.0 • Sizes from 2 x 16"/50 x 15 mm _I 3450 69.9 95 121 80 246 118 3.6 through 8 x 4'/200 x 100 mm 3(a)t 920 500 350 3.81 5.00 4.63 3.16 9.70 531 8.4 8.8 So___ 3450 88.9 97 127 118 80 246 135 3.8 4.0 133.0 x 2 1 92014 500 250 3.75 430 - 3.17 8.00 3.88 8.0 - 50 3450 63.5 95 114 81 203 99 3.6 M 920 500 350 3.81 5.00 3.00 9.46 531 8.0 - 80 3450 88.9 97 127 - 76 240 135 3.6 TABLE CONTINUED ON PG.4 IMPORTANT NOTES: "Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet.Specify choice on order. mated to one another # Center of run to end of fitting. to achieve cross connections. T Female threaded outlets are available to NPT and BSPT specifications. See page 7 for Fire Protection approvals and pressure ratings. . (a)British Standard female pipe threaded outlet is available as listed.Specify'BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 21/2"BSPT clearly on order. §Vds approved for fire protection services e LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. r rrww.victaulic.com �ctauiild VICTAUuC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.O 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_M 11.02 3 CARBON STEEL PIPE-HOLE CUT PRODUCTS 1 1.02 • Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style M]x.Work Appr A. Rio 1 No. Pressure: Dlrnensron_ Wf.ight EIJI Run x Bsanch Hole V t• Female Nominal Size 920 Diameter T" Thd. Gn. w V 2 Thd. Gre. V r �__7 Inches a psi +0.13 Inches Inches Inches Inches Inches Inches lbs. tbs. mm 920N kPa -0.00. mm. mm mm ere . mm mm 14 .1 ., smi } TABLE CONTINUED FROM PAGE 3 �� V 139.7 x 11.6 t 920N 500 2.00 3.78 4.50 - 3.30 8.23 3.25 7.0 - non S r� � 40 I 3450 50.8 96 114 84 209 83 3.2 l �� 2 t 500 250 3.75 4.50 - 3.30 8.23 3.88 9.0 - ■e ��( 9_ON 3450 63.5 95 114 84 209 99 4.1 W V 6 114(a) ,I 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 y 150 x_32(b) i 9-ON 3450 445 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1'h(a)t° 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40(b) ` 3450 50.8 112 130 • 130 96 232 83 2.4 2.3 2(a)t° 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 T 920 r �_Z 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 2 h 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 83 7.6 65 3450 69.9 110 130 130 94 267 118 18 3.4 I •iin i n-r• T nor 76.1mmd 920 500 2.75 4.15 - 5.21 3.69 10.51 4.63 - 8.4 i 3450 69.9 105 132 94 267 118 3.8 � 4 Al i 3(a)t 920 500 3.50 431 5.50 5.13 3.69 1031 5.31 9.9 8.4 � IVI 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a)t° 500 4.50 3.31 5.75 5.38 3.69 1051 6.25 10.1 10.1 • 100 920 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1'%(a) 500 2.00 4.41 5.13 _ 3.63 9.40 3.25 7.8 159.0 x 40 920N 3450 50.8 112 130 92 239 83 3.5 - 2(a) 500 2.50 4.38 5.13 _ 3.63 9.40 3.88 8.0 - • Provides a direct branch connection at 50 920N 3450 63.5 111 130 92 239 99 3.6 - any location where a hole can be cut 76.1 mm I 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 69.9 111 140 130 92 239 118 4.3 4.3 3 I 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 1 420 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal --_.1 113 108.0mm 920 3450 1143 4.50 4.45 - 137 92 239 155 538 3.63 9.40 6.12 - 4.5 10.0 • Request Publication 11.03 for 4 ; 92C, 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 3450 114.3 95.80 146 - 92 239 159 8.2 TABLE CONTINUED ON PG.5 • Pressure rated up to 500 psi/3450 kPa ••Center of run to engaged pipe end,female threaded cutlet only(dimensions approximate). on steel pipe;also available for use t Available with grooved or female threaded outlet Specify choice on order. with HDPE pipe # Center of run to end of fitting. • Sizes from 2 x W/50 x 15 mm N Female threaded outlets are available to NPT and BSPT specifications. through 8 x 47200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a)British Standard female pipe threaded outlet is available as listed.Specify'BSPT"clearly on order. (b)For 76.1 mm threaded outlet,specify 2W BSPT clearly on order. §Vds approved for fire protection services °LPCB approved for fire protection services IMPORTANT NOTES; 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK.OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY,ALL RIGHTS RESERVED. I11rt.a1UI1C 11.(;2 4 . CARBON STEEL PIPE-HOLE CUT PRODUCTS 11.02 r. Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Style Max.Work Aporor. Size No. •ressure' Dimensions Weight Each +0.13- he .yes. h. ch Z Ths. Gm s .-( r Z->. p .00 Inches Inches Inches Inches Inches Inches Lbs. Lbs. ■ r kPa -0.00 mm mm mm mm mm mm kg kg TABLE CONTINUED FROM PAGE 4 p.m% �� 1 500 1.50 3.88 4.56 - 3.79 9.34 2.75 8.0 V 165.1 x 920N - �� 1 25 3450 38.1 99 116 96 237 70 3.6 itGr r=r, m (^1 11/4 o 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 Qh 32 92GN 3450 44.5 113 130 - 96 237 83 3.8 - \�� I V I 116(a)to 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2(a)t 92GN 500 2.50 4.38 5.t3 5.13 3.79 934 3.88 8.5 6.0 50 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1 mm 920 500 2.75 4.01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 �. „ Z 3450 69.9 110 130 132 92 267 118 3.9 3.4 T 77 3�80 0 920 3450 500 3.50 88.9 1130 140 130 3.63 1 267 135 4.6 3.8 V '11r r-- r-r T yr e 4(a)fo 1 920 500 4.50 3.81 5.75 5.38 3.63 1051 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 �� T u 8 x 2 50 t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 I I 200 50 3450 69.9 138 157 159 122 316 114 5.3 5.3 21(a)t 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 • 65 920 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 500 2.75 5.25 - 6.25 4.81 12.42 4.56 - 11.5 76.1 mm n 920 3450 699 133 159 122 316 116 5.3 y 3 laity 500 3.50 531 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 920 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4(a)to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 . 3450 114.3 122 171 162 122 316 159 6.9 5.7 "r Center of run to engaged pipe end,female threaded outlet only(dimensions approximate). • A pressure responsive gasket provides t Available with grooved or female threaded outlet.Specify choice on order. the seal # Center of run to end of fitting. • Request Publication 11.03 for # Female threaded outlets are available to NPT and BSPT specifications. Mechanical-T cross assemblies @ See page;for Fire Protection approvals and pressure ratings.' • Pressure rated up to 500 psi/3450 kPa (a)British Standard female pipe threaded outlet is available as listed.Specify"BSPT"clearly on order. on steel pipe;also available for use (b)For 76.1 mm threaded outlet,specify 2W BSPT clearly on order. with HDPE pipe 8 Vds approved for fire protection services 0 LPCB approved for fire protection services • Sizes from 2 x 1/2750 x 15 mm O Approved for use in China by Tianjin Approvals Company. through 8 x 4"/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.O 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jotaulid REV M 11.02 5 CARSON STEEL PIPE-HOLE CUT PRODUCTS 1 1.02 Mechanical T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point(1)and(2)for the Style 920,920N and 929 Mechanical-I°fittings can best be expressed in terms of the pressure difference across the inlet and branch.The pressure difference can be obtained from the relationship below. 0 Cy and Kv Values Values for flow of water at+60`F/+16°C are shown in the table below. 0 Formulas for C ,K.Values: LP= Q' Where: AP = Q` Where: _ Ir\1 C,' Q=Flow(GPM) K n _______\Ilf/ " Q=Flow(m/h) �� AP=Pressure Drop(psi) AP=Pressure Drop(bar) Ei0= C"x i1P C =Flow Coefficient Q = K,x AP K =Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule 40 Carbon Steel Pipe (per UL 213,Sec.16) nIITLET 47E IT=120)1 FT NOMINAL ACTUAL DIAMETER O.D. In/mm Infirm GROOVED 1 THREADED GROOVED THREADED h i i 0.840 I _ j 11 15 213 I 2 9.4 if 1.050 16 20 26.7 � 4 - 13.7 - 1 1.315 21 25 33.7 8 1.8 1 V4 1.660 50 48 32 _ 42.7 51/2 6 42.9 41.1 1 h 1.900 11 11 53 53 40 98.3 I 45.4 45.4 2 2.375 112 104 50 60.3 9 10'h 96 891 21/2 2.875 I 119 150 65 73.0 I 20 12 Yx 102 128.5 76.1 mm 3.000 16, - 151 76.1 138.1 3 3.500 14 15'1 249 237 80 88.9 213.4 203.1 q 4.500 421 401 100 114.3 20 22 360.8 343.6 t Hazen-Williams coefficient of friction is 120. •Pipe with a wall thickness of 0.165in14.2mm. r, www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK",OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaUlld 11 02 € REV M CARBON STEEL PIPE-HOLE CUT PRODUCTS 11.02 iv Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication.Listings/Approvals are subject to change and/or additions by the approvals agencies.Contact Vlctaulic for performance on other pipe and the latest Ilstings and approvals. Approval Agency F.p.• Rated Working Pressures—psdkPa _ Actual Nominal Outside -- _ _ _ .-, _....._ Vds Size Diameter Incheslmm Inches/mm Inches/nue Schedule UL ULC FM I.PCB (Style 920) (Style 92014) 21/2-6 2.875-6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2-4 2.875-4.500 All OF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2-4 2.875-4.500 All SF 300 300 300 290 232 362 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 6 6.625 3 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10,40 400 145— — — — 200 _ 219.1 2755 1000 8 8.625 300 _ 250 — 145 — 200 219.1 3,4 10 2065 1724 1000 8 8.625 3,4 30,40 300 — 300 — 145 _ 200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The VIc-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4-8'/100-200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 VIc-Ball Valve.The Vic-Tap II Is capable of tapping Into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100 mm, 51125mm,61150mm and 81200 mm diameter pipe.The Style 931 comes with a 25 h'/65mm grooved outlet. i 1 1 The drill motor is an electric motor with ground fault circuit interrupter(GFCI)in accordance with (1 safety codes. '.1!- i 71 For more information,refer to publication 24.01. ilii 1./.1 www.victaulic.com CtaUlld VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED, FEV 10 1! ;,2 % CARBON STEEL PIPE- HOLE CUT PRODUCTS , Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N • INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly Instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 11.02 1480 REV M UPDATED 03/2012 ✓CtauIid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2012 VICTAUUC COMPANY.ALL RIGHTS RESERVED. 11.02_L Pipe Hangers Fig.200- "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TOLCO - Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B3170NFF) c C)us Fig.200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) USTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications y Function: For fire sprinkler and other general piping purposes. Knurled v swivel nut design permits hanger adjustment after installation. Features: ,.., ;_ • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe _ types and protect CPVC plastic pipe from abrasion.Captured design "' keeps adjusting nut from separating with hanger. Hanger is easily tifi einstalled around pipe.For hanger with non-captured nut order Fig. 200S. i• (21/2" (65mm)thru 8" (200mm))Spring tension on nut holds it securely in 4- 1 hanger before installation.Adjusting nut is easily removed. s' Approvals: Underwriters Laboratories listed(1/2" (15mm)thru 8" (2oomm)) =� Fg.210-+h ap in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM)(3/4" (20mm)thru 8" (200mm)). F'°' 110 2 Fa2082+heo20e1 Conforms to Federal Specifications WW-H-1 71 E&A-A-1192A,Type 10 _ and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. - Maximum Temperature: 650°F(343°C) ; Finish: Pre-Galvanized. Stainless Steel xg materials will be supplied with (2) hex nuts a ,,,, . .1,.:::: in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of ig:;.- FM DS 2-0. Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 **--• Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) / 200-1/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/e (201 3/8'-16 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) / 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) . 200-2 2' (50) 3/s"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 4 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) 3/s"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) - 200-5 5" (125) 1/2%13 91/6" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) - 200-8 8" (200) 1/2"-13 131/8" (333.4) 83/4' (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by E:T•N VERTICAL MOUNT siumm, SAMMYS® for Wood rllir,'h., i Not less than 2"nominal width Wood Flooring Features (1 � •No pre-drilling required. ") Nolless!han •Quick to install using the Sammy 3•nominal Nut Driver with an 18V cordless thickness(2.117) (depth ar side wood Joist - drillidriver. d rental member) Saves time from traditional r Daub �wetrack methods. For vertical use- CeirN install in center of lower face. •Reduces installation cost. • Minimum 2"embedment Into base i material for NFPA 13 compliance. ,t.-i. Composite(Truss •Made in the U.S.A. a Consult tn:ss manufacturer for recommercec.rstallation poinl. frf� _-----� 'Predril rig may ne required rot GST ---..,�� 25.360.Tool available on page l0 mow. � Fes, I It Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Qty Qty — 1I4" 8002957 GST 100 1/4 x 1' 210 (7/16"OSB) 25 125 670 (314"Ply) ' 114" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 appr 114" 8004957 GST 300 1/4 x 3" 2060 (Fir)VIIIMIMMILIMENI 25 125 318" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 to. 318" 8007957 GST 10 1/4 x 1" 210 (7116'OSB) '300 25 125 670 (3A'Ply) _ II w`."0 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 _ 3/8" 8068925 GST20-SS 1/4x2' 1760(Fir) 850 25 125 Q- 3/8" 6009925 GST 25-380 3/8 x 2-112" 2113 (Fir) 1500 25 125 " 3/8° 8010957 GST 30 114 x 3° 2060(Fir) 1500 �„ 1475 25 125 414 61aek Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 part 0 811 3.91G 3/8" 8011925 GST 40 1/4x4" 2180(Fir) 25 125 3/8" 8012925 GST 60 1/4 x6" 2230 (Fir) 25 125 _ NNW 1/2" 8013925 GST 2 114 x 2" 1760(Fir)' 25 125 1/2" 8014925 GST 2.5-380 3/8 x 2-1/2' 2113 (Fir) 25 125 112" 8015925 GST 3 1/4 x 3" 2275(Fir)'' 25 125 — i 1/2" 8016925 GST 4 114 x 4" 2180 (Fir) 25 125 ,; 1/2' 8017925 GST 6 114 x 6" 2230 (Fir) m 25 125 #14 SW Red Nut Driver Part#8114910 SAMMY Swivel Head' for Wood ii)siialls VERTICALLY and swivels up ru i7'in .vvood structure Product Features I •Eliminates distortion of threaded rod. •Saves time from traditional methods. II 1 •Accommodates up to 3'4"x 12 pitch roof. •Reduces installation cost. I L- •Allows 17°deflection from vertical. •Made in the U.S.A. 6 Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Box Case Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Thickness Qty Qty !?•4,• 3/8" 8139957 SH-GST 20 114x2" 1257(Fir) 1050 1475 25 125 125 Q• • 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver rij SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 4 19 s rswu w u s a. � ••• SAMMYS`„ HORIZONTAL MOUNT SIDEWINDERS® for Wood Iii i.al.,;1!.Jr /ONTALLr c;;. I Na less than 2'nominal width Product Features (I-1/2")up to 3-1/2'pipe:not less than 3'(2-112')nominal width 4'&5'pipe •No pre-drilling required. _.11,'.w4www 4-0 1 Floor Jast •Quick to install using the Sammy Minimum 2.1/2"from bottom for branch lines.Minimum 3'from Nut Driver with an 18V cordless bottom for main Ilnes.Exception:This drill/driver. requirement shall not apply to 2'or thicker nailing strips resting on top of steel beams. •Saves time from traditional • methods. •Reduces installation cost. • I •Made in the U.S.A. CompositelTruss - • Consult truss manulachxer for /. recommended installation ponl. t - 'Pre-drilling may be required for Model tf SSG 25.380(tools available or cg 10 Approvals Rod Part Model Screw Ultimate UL Test Box Case Size Number Descriptions Pullout(lbs) Load fibs) Qty Qty i : tii- 114" 8018957 SWG 100 1/4 x 1" 622(Fir) 25 125 114" 8019957 SWG 200 114x2' 1725(Fir) 25 125 125 3/8' 8020957 SWG 10 114 x 1' 622(Fir) 300 25 3 8' 8021957 SWG 20 1/4x2' 1725(Fir) 1050 25 125 L+. 3/8" 8073925 SWG 20-SS 1725(Fir) 850 25 125 #14 SW Red 4. 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249(Fir) 1500 25 125 Nut Driver 3/8' 8023925 SWG 30 1/4x3" 1884(Fir) 25 125 Part 68114910— -- 1 rs,I `IISTA''' •• • VERTICAL ; • '1•6i •' `EE : TA I'TIO1 E HORIZONTAL "••• T' 1.Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. 1.Insert the appropriate nut driver into a 3/8"or 1/2"portable drill. 2.Insert the SAMMYS into the#14(black)nut driver(p/n 8113910).Drill 2.Insert the SAMMYS into the#14SW(red)nut driver(p/n 8114910).With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. 3.Push the face of the nut driver tight to the member.When the - , nut driver spins freely on the SAMMYS,stop drill and remove, 3.When the nut driver spins free on the SAMMYS.stop the drill and remove. 4.The SAMMYS is now ready to twelve 1/4',3/8",1/2"or metric all thread rod,bolt stock.(The 1/2"requires the#14SW red nut driver) 4.The unit is now ready to receive 1/4",3/8"or metric all thread rod or bolt stock. Note:When installing DSTR,follow the above instructions, then add retainer nut and torque to 20 foot lbs.for maximum Note:When installing SWDR,follow the above instructions,then add retainer nut pullout in purtin steel. and torque to 20 foot lbs.for maximum pullout in purlln steel.31 7,1,0",..\14, 7..,, , 9. hIiIjLHL m, SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe instalation each time.When the face of the driver comes into contact with the material you are instaling into,continue drding until nut driver spins free.Instalation is then complete.Warranty requires the use of the appropriate nut driver for installations. 5 To find a distributor near you.call 800-BUILDEX Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) r B3205L - Threaded Rod (right& left hand threads) / TL • Specify Length `lv" Size Range: 3/8"-16 thru 3"-4 rod •L- �`� Material: Steel ,� Function: Recommended for use as a hanger support in hanger assemblies. TL .11" Rod is threaded on both ends with right hand threads of the length shown.Also A available with left and right hand threads-specify Fig. B3205L when ordering. Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 83205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 83205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/e x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.37) 83205-13/4 x'1' 13/4"-5 7" (177.8) _ 18600- - (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) 83205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) 83205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length 40, • ;v„ * Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length°"math' \)1,' d\ Material: Steel J�� �am le Maximum Temperature: 750°F(399"C) .$ �o Finish: Plain. Contact B-Line for alternative finishes and materials. II i Order By: Part number, rod diameter and finish �Q Part No.-Size x Length Threads Recommended Load Approx.WtJ100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/s"x 120 99-3/8"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) - ATR 5/8"x 120 99-5/e"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) ATR 718"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) ATR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 236 Revised 4,28/2014 by Ejard HYDRAULIC CALCULATIONS for - Job Information r Project Name:Washington Square Too Infill 11 Contract D Contract No.:C14 4630 City: Portland, OR 97223 JUN - 4 2014 Project Location: 9585 SW Washington Square Date:6/2/2014 Contractor Information GTYQF fiGARD t BUILDING 1. ISION Name of Contractor: Wyatt Fire Protection Address: 9095 SW Bumham St City: Tigard, OR 97223 Phone Number: 503-684-2928 E-mail:a.payne @wyattfire.com Name of Designer: Ashley Payne Authority Having Jurisdiction: City of Tigard Design Remote Area Name DesignArea_1 Remote Area Location Occupancy Classification Commercial_Ordinary 1 • Density(gpm/ft2) 0.15 Area of Application(ft2) 2568 Coverage per Sprinkler(ft2) 107 Number of Calculated Sprinklers 24 4?,VCTUR9 ciL In-Rack Demand(gpm) 0 \C‘" D PRO• mac.•;' N£!,►�� Special Heads Hose Streams(gpm) 0 Total Water Required(ind.Hose Streams)(gpm) 509.1 ` aiN .� Required Pressure at Source(psi) 30.3 4QY 23�� D. L Type of System Wet EXPIRES: 12-31-14 Volume-Entire System (gal) 29.1 gal Water Supply Information Date Location Source Notes File:C:\Users\Ashley\AppData\Roaming\TycoFP\SprinkCALC31Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 Tyco Fire Protection Products Page 1 . . , . 1 .• • Job:Washington Square Too Infill Node Labels: Node Reference Pipe Labels: Off Diagram for Design Area : DesignArea_1 nO2 _-------11 MO2 � -� . �" h0.5----- ?12 1b-- ■R1 f hpS 1_. -...„.` — -j r--�416-----*---- � h f4 n06 hi4 fff3 �n10 r.1�-r` hiA16 j69h1D---- �r.18 .i� +t.1a--'- 78 1124----- -----s`s.t$20 ".--.,h h22 File:C:1UsersWshley\AppData1 Roaming\TycoFPISprinkCALC31Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 To Fire Protection Products Page 2 Job:Washington Square Too Infill Hydraulic Analysis for : DesignArea_1 - Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams • Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 509.1 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 509.1 Other Required Margin of Safety(psi) 0 Base of Riser -Pressure(psi) 30.3 Base of Riser -Flow(gpm) 509.1 Demand w/o System Pump(s) N/A File:C:\U sers\Ashley\AppData\Roaming\TycoFP\SprinkCALC3\Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 Tyco Fire Protection Products Page 3 • • Job:Washington Square Too Infill Hydraulic Analysis for : DesignArea_1 f System afraid J 36- ro -- a; yN d 15 10 5 0 • 0 200 300 400 flip rU0 Flow. gin,' File:C:\Users\Ashley\AppData\Roaming\TycoFP\SprinkCALC31Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 Tyco Fire Protection Products Page 4 Job:Washington Square Too Infill Hydraulic Analysis for : DesignArea_1 Graph Labels Label Description Values Flow (gpm) Pressure (psi) D1 Elevation Pressure 0 0.6 D2 System Demand 509.1 30.3 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor - - Density Flow Pressure Density Flow Pressure (ft2) (gpm/psis/z) (gpm/ft2) (gpm) (psi) (gpm/R2) (gpm) (psi) h03 Overhead 107 5.6 0.15 16.1 8.2 0.259 27.7 24.4 Sprinkler h11 Overhead 107 5.6 0.15 16.1 8.2 0.253 27.1 23.4 Sprinkler h01 Overhead 107 5.6 0.15 16.1 8.2 0.238 25.5 20.7 Sprinkler h02 Overhead 107 5.6 0.15 16.1 8.2 0.225 24.1 18.5 Sprinkler h04 Overhead 107 5.6 0.15 16.1 8.2 0.228 24.4 18.9 Sprinkler h05 Overhead 107 5.6 0.15 16.1 8.2 0.221 23.6 17.8 Sprinkler h06 Overhead 107 5.6 0.15 16.1 8.2 0.216 23.1 17.1 Sprinkler h07 Overhead 107 5.6 0.15 16.1 8.2 0.178 19.1 11.6 Sprinkler h08 Overhead 107 5.6 0.15 16.1 8.2 0.19 20.3 13.2 Sprinkler h09 Overhead 107 5.6 0.15 16.1 8.2 0.192 20.5 13.5 Sprinkler h10 Overhead 107 5.6 0.15 16.1 8.2 0.18 19.2 11.8 Sprinkler h12 Overhead 107 5.6 0.15 16.1 8.2 0.202 21.6 14.9 Sprinkler h13 Overhead 107 5.6 0.15 16.1 8.2 0.197 21.1 14.2 Sprinkler h14 Overhead 107 5.6 0.15 16.1 8.2 0.196 20.9 14 Sprinkler h15 Overhead 107 5.6 0.15 16.1 8.2 0.223 23.8 18.1 Sprinkler h16 Overhead 107 5.6 0.15 16.1 8.2 0.208 22.3 15.8 Sprinkler h17 Overhead 107 5.6 0.15 16.1 8.2 0.181 19.3 11.9 Sprinkler File:C:\Users\Ashley\AppData\Roaming\TycoFP\SprinkCALC3\Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 Tyco Fire Protection Products Page 5 h18 Overhead 107 5.6 0.15 16.1 8.2 0.177 19 11.5 Sprinkler h19 Overhead 107 5.6 0.15 16.1 8.2 0.175 18.7 11.2 Sprinkler h20 Overhead 107 5.6 0.15 16.1 8.2 0.193 20.7 13.6 • Sprinkler h21 Overhead 107 5.6 0.15 16.1 8.2 0.155 16.6 8.8 Sprinkler h22 Overhead 107 5.6 0.15 16.1 8.2 0.154 16.5 8.6 Sprinkler h23 Overhead 107 5.6 0.15 16.1 8.2 0.15 16.1 8.2 . Sprinkler h24 Overhead 107 5.6 0.15 16.1 8.2 0.167 17.9 10.2 Sprinkler 4 • a File:C:\Users\Ashley\AppData\Roaming\TycoFP\SprinkCALC3\Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 Tyco Fire Protection Products Page 6 Job:Washington Square Too Infill Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Elev Hgroup Tot. Pres. Discharge K-Fact. Req. Discharge Req. Pres. I ft psi gpm gpm/psi1/2 gpm psi A 12 SUPPLY 30.3 -509.1 n01 12 NODE 28.8 h03 12 HEAD 24.4 27.7 5.6 16.1 8.2 n03 12 NODE 24 n04 13.5 NODE 21.1 h11 12 HEAD 23.4 27.1 5.6 16.1 8.2 n11 12 NODE 23.3 n12 13.5 NODE 21 n13 13.5 NODE 19 n02 13.5 NODE 27.3 h01 13.5 HEAD 20.7 25.5 5.6 16.1 8.2 h02 13.5 HEAD 18.5 24.1 5.6 16.1 8.2 h04 13.5 HEAD 18.9 24.4 5.6 16.1 8.2 h05 13.5 HEAD 17.8 23.6 5.6 16.1 8.2 h06 13.5 HEAD 17.1 23.1 5.6 16.1 8.2 n05 13.5 NODE 16.3 n06 13.5 NODE 14.7 - n07 13.5 NODE 13.5 n08 13.5 NODE 12.2 h07 13.5 HEAD 11.6 19.1 5.6 16.1 8.2 h08 13.5 HEAD 13.2 20.3 5.6 16.1 8.2 n09 13.5 NODE 13.1 h09 11.5 HEAD 13.5 20.5 5.6 16.1 8.2 n10 13.5 NODE 12.4 h10 13.5 HEAD 11.8 19.2 5.6 16.1 8.2 - h12 13.5 HEAD 14.9 21.6 5.6 16.1 8.2 n14 13.5 NODE 14.3 h13 11.5 HEAD 14.2 21.1 5.6 16.1 8.2 h14 13.5 HEAD 14 20.9 5.6 16.1 8.2 h15 13.5 HEAD 18.1 23.8 5.6 16.1 8.2 h16 13.5 HEAD 15.8 22.3 5.6 16.1 8.2 n15 13.5 NODE 15.3 h17 13.5 HEAD 11.9 19.3 5.6 16.1 8.2 n16 13.5 NODE 11.5 h18 11.5 HEAD 11.5 19 5.6 16.1 8.2 h19 13.5 HEAD 11.2 18.7 5.6 16.1 8.2 h20 13.5 HEAD 13.6 20.7 5.6 16.1 8.2 n17 13.5 NODE 13 n18 13.5 NODE 11.6 b. n19 13.5 NODE 10.4 _ h21 13.5 HEAD 8.8 16.6 5.6 16.1 8.2 n20 13.5 NODE 8.4 h22 11.5 HEAD 8.6 16.5 5.6 16.1 8.2 h23 13.5 HEAD 8.2 16.1 5.6 16.1 8.2 File:C:\Users\Ashley\AppData\Roaming\TycoFP\SprinkCALC3\Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 Tyco Fire Protection Products Page 7 Job:Washington Square Too Infill Hydraulic Calculations/Fluid Delivery Time Analysis Node Data Node# Elev Hgroup Tot. Pres. Discharge K-Fact. Req. Discharge Req. Pres. i ft psi gpm gpm/psilh gpm psi h24 13.5 HEAD 10.2 17.9 5.6 16.1 8.2 File:C:\Users\Ashley\AppDatalRoaming\TycoFP\SprinkCALC3\Support\Projects\Untitled.tyc3 Date 6/2/2014 Copyright©2002-2012 Tyco Fire Protection Products Page 8 Job name:Washington Square Too Infill Sheet number: PIPE INFORMATION K Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) a Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) h23 13.5 5.6 16.1 1 2.17 120 8.2 n20 13.5 16.1 1.049 0 0.0863 0 2.17 0.2 n20 13.5 16.5 1 1.13 120 8.4 h21 13.5 5.6 32.5 1.049 0 0.3188 0 1.13 0.4 h21 13.5 5.6 16.6 1.25 lx(us.Tee-Br)=6 3.17 120 8.8 n19 13.5 49.1 1.38 6 0.1798 0 9.17 1.6 n19 13.5 17.9 1.5 lx(us.90)=4 4.17 120 10.4 n18 13.5 67 1.61 4 0.1509 0 8.17 1.2 n18 13.5 0 1.5 lx(us.90)=4 5 120 11.6 n17 13.5 67 1.61 4 0.1509 0 9 1.4 n17 13.5 0 1.5 4.25 120 13 h20 13.5 5.6 67 1.61 0 0.1509 0 4.25 0.6 h20 13.5 5.6 20.7 1.5 6.67 120 13.6 n15 13.5 87.6 1.61 0 0.2484 0 6.67 1.7 n15 13.5 57.1 2 2.83 120 15.3 h16 13.5 5.6 144.7 2.067 0 0.1862 0 2.83 0.5 h16 13.5 5.6 22.3 2 9.5 120 15.8 h15 13.5 5.6 167 2.067 0 0.2428 0 9.5 2.3 h15 13.5 5.6 23.8 2 2.75 120 18.1 n13 13.5 190.8 2.067 0 0.3109 0 2.75 0.9 n13 13.5 63.6 2.5 lx(us.90)=8.24 4.33 120 19 n12 13.5 254.4 2.635 8.24 0.1624 0 12.57 2 n12 13.5 0 2.5 1x(us.90)=8.24 1.5 120 21 n11 12 254.4 2.635 8.24 0.1624 0.6 9.74 1.6 n11 12 0 3 2.08 120 23.3 hll 12 5.6 254.4 3.26 0 0.0576 0 2.08 0.1 ' h l l 12 5.6 27.1 3 9.17 120 23.4 n03 12 281.5 3.26 0 0.0694 0 9.17 0.6 n03 12 150.3 3 2.83 120 24 h03 12 5.6 431.8 3.26 0 0.1534 0 2.83 0.4 h03 12 5.6 27.7 3 lx(us.Tee-Br)=20.16 5.08 120 24.4 . n01 12 459.5 3.26 20.16 0.1721 0 25.24 4.3 • n01 12 49.6 3 7.21 120 28.8 A 12 509.1 3.26 0 0.208 0 7.21 1.5 h22 11.5 5.6 16.5 1 lx(us.Tee-Br)=5 2 120 8.6 n20 13.5 16.5 1.049 5 0.0904 -0.9 7 0.6 ©2006 National Fire Protection Association Page 9 Job name:Washington Square Too Infill Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) a Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psis/2) (gpm) (in) i) (ft) (ft) (psi) (psi). h24 13.5 5.6 17.9 1 2.17 120 10.2 n19 13.5 17.9 1.049 0 0.1053 0 2.17 0.2 h19 13.5 5.6 18.7 1 2.17 120 11.2 n16 13.5 18.7 1.049 0 0.115 0 2.17 , 0.2 n16 13.5 19 1 1.13 120 11.5 h17 13.5 5.6 37.7 1.049 0 0.4202 0 1.13 0.5 h17 13.5 5.6 19.3 1.25 lx(us.Tee-Br)=6 8.16 120 11.9 n15 13.5 57.1 1.38 6 0.2378 0 14.16 3.4 h18 11.5 5.6 19 1 lx(us.Tee-Br)=5 2 120 11.5 n16 13.5 19 1.049 5 0.1178 -0.9 7 0.8 h07 13.5 5.6 19.1 1 lx(us.90)=2.49 4.16 120 11.6 n08 13.5 19.1 1.097 2.49 0.0956 0 6.65 0.6 _1 n08 13.5 0 1 lx(us.Tee-Br)=6.22 7 120 12.2 n07 13.5 19.1 1.097 6.22 0.0956 0 ' 13.22 1.3 n07 13.5 60.1 1.5 lx(us.90)=4.92 2.17 120 13.5 n06 13.5 79.2 1.68 4.92 0.1673 0 7.09 1.2 n06 13.5 0 1.5 lx(us.90)=4.92 4.92 120 14.7 n05 13.5 79.2 1.68 4.92 0.1673 0 9.84 1.6 n05 13.5 0 1.5 4.25 120 16.3 h06 13.5 5.6 79.2 1.68 0 0.1673 0 4.25 0.7 h06 13.5 5.6 23.1 2 9.5 120 17.1 h05 13.5 5.6 102.3 2.157 0 0.0796 0 9.5 0.8 h05 13.5 5.6 23.6 2 9.5 120 17.8 h04 13.5 5.6 125.9 2.157 0 0.117 0 9.5 1.1 h04 13.5 5.6 24.4 2 lx(us.90)=6.15 7.08 120 18.9 n04 13.5 150.3 2.157 6.15 0.1623 0 13.23 2.1 n04 13.5 0 2 lx(us.Tee-Br)=10 1.5 120 21.1 n03 12 150.3 2.067 10 0.1997 0.6 11.5 2.3 h10 13.5 5.6 19.2 1 lx(us.90)=2.49 4.17 120 11.8 n10 13.5 19.2 1.097 2.49 0.0969 0 6.66 0.6 n10 13.5 0 1 lx(us.Tee-Br)=6.22 5 120 12.4 • n07 13.5 19.2 1.097 6.22 0.0969 0 11.22 1.1 ▪ h08 13.5 5.6 20.3 1 0.83 120 13.2 • n07 13.5 40.9 1.097 0 0.3918 0 0.83, 0.3 h09 11.5 5.6 20.5 1 lx(us.90)=2.49 2 120 13.5 n09 13.5 20.5 1.097 2.49 0.1095 -0.9 4.49_ 0.5 ©2006 National Fire Protection Association Page 10 Job name:Washington Square Too Infill Sheet number: PIPE INFORMATION r Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) 4 Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/Psi'/2) (gpm) (in) (It) (ft) (psi) (Psi) n09 13.5 0 1 1 120 13.1 h08 13.5 5.6 20.5 1.097 0 0.1095 0 1 0.1 h14 13.5 5.6 20.9 1 2.16 120 14 n14 13.5 20.9 1.049 0 0.1412 0 2.16 0.3 n14 13.5 21.1 1 1.13 120 14.3 h12 13.5 5.6 42 1.049 0 0.5126 0 1.13_ 0.6 h12 13.5 5.6 21.6 1.25 lx(us.Tee-Br)=6 8.17 120 14.9 n13 13.5 63.6 1.38 6 0.2906 0 14.17 4.1 h13 11.5 5.6 21.1 1 lx(us.Tee-Br)=5 2 120 14.2 n14 13.5 21.1 1.049 5 0.1428 -0.9 7 1 h02 13.5 5.6 24.1 1 14.5 120 18.5 h01 13.5 5.6 24.1 1.097 0 0.1475 0 14.5 2.1 1 h01 13.5 5.6 25.5 1 lx(us.90)=2.49 9.33 120 20.7 n02 13.5 49.6 1.097 2.49 0.5603 0 ! 11.82 6.6 n02 13.5 0 1 1.5 120 27.3 n01 12 49.6 1.097 0 0.5603 0.6 1.5 0.8 * Discharge shown for flowing nodes only i ©2006 National Fire Protection Association Page 11 o�- S r c • • ...N M MAXI i!i!i!i!i!i!igi!i�i!i•!i_P�..�R manimim irr I 11•I 6 t • i1t iti till) JUN - 4 2014 INSULATION TO BE ���©����� EXISTING HORIZONTAL SIDEWALL SPRINKLER . PROVIDED BY OTHERS FP1 TO BE DEMOLISHED RI)1ln1tl►_r;�III N' — '41 / EXISTING WALL TO BE DEMOLISHED H 2 a • 1 •®/ 1 0® 3 / ,O 14-6 9-4 7-212 M TH no �Op 1 n0 o TO EXISTING SYSTEM I - M 4-2 1 h06 h0 h0 N O® . ®413 O� 926/ O 9-6 / #7-1 , o CROSS SECTION 1 _@ G� 4 NOT TO SCALE n09 ' t- 12-2 �• ALL PIPING 2- 1/2" NOMINAL DIAMETER m - ,T, OR GREATER TO BE DYNA-FLOW -= , �►' 1 ® SCHEDULE I 0 REPLACEMENT WITH _ �, 4-2 ® ® ® GROOVED COUPLINGS AND FITTINGS —'- �1 `4$. M i 1 112 Ohl 112 O 2 / O 2 12 k 4-3 6-8 2-10 9-6 2-• 4-4 w •°° x.`J ' ®► ®112 l gab - O , -2r 4-2 — IL— -a— — a .- n d _ .___.___.__..._ :' la 1 ALL PIPING 2 NOMINAL DIAMETER /i 04 p•'%<< "��� "��® ` ��,® OR LESS TO BE DYNA-THREAD i d;,� -- Ali i N .N .� SCHEDULE 40 REPLACEMENT WITH �RVCTU' / ? FirGr P 1!! DUCTILE IRON SCREWED FITTINGS ��ED Na ; ``®.; ` ` � -.1i- 5 1111i 5 Eir ` � It gilik 'aiN =;� •. PARTIAL REFLECTED CEILING PLAN HYDRAULIC DATA �oY , 2'° DEMAND FLOW AT'A" 509.I gpm D. k- SITE PLAN 1/8"=1'-O" DEMAND PRESSURE AT "A" 30.3 psi NOT TO SCALE 110/ smmmmi EXPIRES: 12-31-14 • 0 4 8' 16' NOTES APPROVALS SPRINKLER SYMBOLS FFE PROTECTION PLAN All hangers to be per NFPA 13 requirements °A E CES 1 N 0 New Upright, 5.6 K-factor, Standard Coverage, 155',Standard Respatee. Qty. 14 WASHINGTON SQUARE TOO FPI NI armovers greater than 2'-0" shill be provided with hangers New Dry Pendant, 5.6 K-factor, Standard Coverage, 155', Standard Response. Qty. 5 W YAT T PERMIT NO Max. sprinkler spacing to be 130 sq. ft. per head. y y 9585 SW WASHINGTON SOARE CONTRACT N0, C14 4630 l a New Dry Horizontal Sidewall, 5.6 K-factor, Standard Coverage, 155', Standard Response. Qty. 5 DRAWN BY �o ee All heads cut in from branch lines. FIRE PROTECTION, INC. TIGARD, OREGON 97223 �" Meets design requirements of NFPA 13 2010 edition. A Existing Horizontal Sidewall to be Demolished 9095 S.W.Burnham DATE 1/8 - 1-0 NI of work area will be ordinary hazard group 1 occupancy. Tigard,OR 97223 DATE JUN 2014 (503)684-2928 Creenberry Construction, 2211 NW Professional Dr, Ste. 201, Corvallis, OR 973.30 FP 1 OF 1