Loading...
Permit CITY OF TIGARD MASTER PERMIT • COMMUNITY DEVELOPMENT Permit#: MST2014 00129 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/20/2014 Parcel: 2S110BC07100 Jurisdiction: Tigard Site address: 12270 SW ASPEN RIDGE DR Subdivision: THORNWOOD Lot: 42 Project: Gallagher Project Description: Installation of residential solar photovoltaic system BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $5,650.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder TemD Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: GALLAGHER,SCOTT A&SARAH L SOLARCITY CORPORATION Required Items and Reports(Conditions) 12270 SW ASPEN RIDGE DR 6132 NE 112TH AVE TIGARD,OR 97224 PORTLAND,OR 97220 PHONE: 503-703-9677 PHONE: 503-894-6903 FAX: 866-445-7459 Total Fees: $358.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. These rules are set forth in OAR 952-001-0010 through QtkR 952- 01-0090. You may obtain a copy of the rules or direct questions to OUNC by call' ,,t0. '32.1987 or .8,0. 32.2344. j .I Issued By: V( Permittee Signature: �,,AOIt Vl• NIIIII Call 503.639.4175 by 7:00 a.m.for the next available inspection This permit card shall be kept in a conspicuous place on the job site until complAti, th. pro:ct. Approved plans are required on the job site at the time of each inspec.•,. Building Permit Annlication Residential RECEIVED , , ,,. , ; ,( , , ,, ,„; , City of Tigard T HIS Or- Permit No.: hT;61 a) 13125 SW Hall Blvd.,Tigard,OR 9722$ I G 4 2014 DdPea d g R : i�i I M iMrEl.. Odra Permit Phone: 503.718.2439 Fax: 503.598.1'960 Inspection Line: 503.639.4175 Dare Ready: 'mss 0 See hoe 2 for Internet: www.tigard-or.gov CITY OFTIGARD "d` �N ss�� tat .ado BUtll DWVISION ' TYPE OF REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees'are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF work indicated on this application. ® I-and 2-family dwelling ❑Commercial/industrial Valuation: S 5,650 ❑Accessory building ❑Multi-family Number of bedrooms: ❑Master builder ❑Other Number of bathrooms: JOB SUE INFORMATION AND LOCATION Total number of floors: lob site address: 12270 SW Aspen Ridge Dr, New dwelling area: square feet City/State/ZIP: Tigard OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: I Project name: Gallagher,Scott A Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees'are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. PV ROOF MOUNT Valuation: S ~ Existing building area: square feet New building area: square feet ® PROPERTY OWNER I ❑ TENANT Number of stories: Name: Gallagher,Scott A Type of construction: Address: 12270 SW Aspen Ridge Dr, Occupancy groups: City/State/ZIP:Tigard OR 97224 Existing: Phone:( 503 ) 703 9677 Fax:( ) New: ® APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* tire Business name:SOLAR CITY WUsfr<rrtArwwhat* Contact name:MELISSA BENTLEY Structural plan review fcc(or deposit): TH FLS plan review fee(if applicable): Address:6132 NE 112 AVE City/State/ZIP:PORTLAND OR 97220 Total fees due upon application: Phone:(503)894 6903 I Fax::(1866)445-7459 Amount received: F-mail:ABENTI,EY(r�SOLARCITY.COM PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES' CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:SOLAR CITY Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6132 NE 112TH AVE Solar Installation Specialty Code checklist. City/State/ZIP:PORTLAND OR 97220 Permit Fee(includes plan review 5180.00 and administrative fees): Phone:(503)894-6903 I Fax:(1866)445-7459 State surcharge(12%of permit fee): $21.60 CCB lic.:180498 Total fee due upon application: $201.60 Authorized signature:( 1.1, I. , r This hiithiopermit 80 days after ait expires if a has been accepted as sot obtained te. 8/01/14 methodology set by Tri-County Building Industry Print name:A. MELISSA I 'Foe TLE Date: Service Board 1:1BuildingtPermits\BUP-RESPernitApp.doc 02/24/2011 440-4613T(1I/02/COM/WEB) • Building Permit Application Checklist One- and Two-Family Dwelling holy` (ATlc-e: USE 0' 1.1' City of Tigard Received g Daldtty; Penult No lig . - -'t 13125 SW Ilall Blvd.,Tigard,OR 97223 Associated permits: I Phone: 503.718.2439 Fax 503.598.1960 11 1i.1A1) 24-Hour Inspection Line: 503.639.4175 ❑ Ekctrical ❑ Pli rot i h Li Mechanical Internet: www.ligard-or.gov ❑ me:, THE FOLLOWING ITEMS ARE REQUIRED FOR !'LAN REVIEW 1 es 1u N;a I Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ • 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district.etc. ❑ ❑ ❑ 3 Verification of Approved plat/lot. 0_ ❑_ f 4 Fire district approval required. Name ol'distriet: ❑ v❑ ❑ 5 Se u tic stem ermit or authorization for remodel. kxistin' s'stem ea+ncit ❑ 0 0 6 Sewer permit. • • U 7 Water district approval. 11 _1 8 Soils report. Must carry original applicable stamp and signature on file or with application. [ 0 9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- D ❑ ❑ basin protection.etc_ 10 3 Complete sets of legible plans. Must he drawn to scale.showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions:property corner elevations(if ❑ ❑ ❑ there is more than a 4-fl.elevation differential,plan must show contour lines at 2-ft.intervals);location of casements and driveway;footprint of structure(including decks):location of wells/septic systems;utility locations:direction indicator:lot area building coverage urea;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors.water heater. ❑ ❑ 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross sections)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑ floor,wall construction,roof construction. More than one cross sect ion may he required to clearly portray construction. Show details of all wall and roof sheathing,roofing.roof slope,ceiling height,siding material.footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendum showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ ❑ prescriptive path anulysisprovide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing_spacing,and bearing 0 ❑ ❑ locations. Show attic ventilation. l8 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems,see item 22,-Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ ❑ ❑_ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Ore on and shall be shown to be a lieable to the project under review. 23 Tliree(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x [7". ❑ ❑ 0 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ []_ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ n _ ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. . ❑ 0 0 27 '`Drawn to scale"indicates standard architect or engineer scale. 0 28 Sile plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ Cr- _ Street'free List. 29 Site pion to include trees and tree protection measures as required by conditions of approval. Trcc locations,driptines, 0 El El and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ Q including decks,patio covers(over non-impervious surface)and acre sory structures to existing residential dwellings on a lot of record approved prior to September 9. 1995. l:1Building\cnnits1BtJP-RESPennitApp.iloc 02/24/2011 440-4613T(I1/02/COM/WI.B) f m Electrical Permit Application RECEIV i , .., ' I, 1 .,I . I Si City of Tigard �'`l. A,i Peralit rlo.:1/ 7/ -&3/ 13125 7182439 '5033 598.19960 AU G 4 201�' a. Other Permit: Inspection line: 503.639.4175 Date Ready/By: 3uric R See Page 2 for Internet: www.tigard-or.gov CITY OF TIGA'�: Sppleme.tal I.fennadoa TYPI of woitIRIIILDING DIVISION PLAN REVIEW ❑New construction ®Addition/alteration/replacement Please check all that apply(submit j sets of plans writema checked below): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ❑Other: where the available fault current D Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. ® I-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less ground,a exceeds ons pcadings.al-we agricultural rY $ amps for an other installations. buildings. ❑Multi-family ❑Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or JOB SrI SITE INFORMATION AND LOCATION D Emergency system. larger separately derived system. ❑Addition of new motor load of ❑"A""E-"i,2""1-3", Job no,: I Job site address: 12270 SW Aspen Ridge Dr, IOOHP or more. occupancy. 9722037 ❑Six or more residential units. D Recreational vehicle parks. City/State/ZIP: Tigard OR 97224 ❑Health-care facilities. D Supply voltage far more Ihan ❑Hazardous locations. 600 volts nominal Suite/bldg./apt.no.: I Project name: Gallagher,Scott A 0 Service or feeder 600 amps or more. FEE SCHEDULE Cross street/directions to job site: mx++atisa I Orr. I pee. I Total I • New residential single-or multi-hotly dwelling unit. Includes attached garage. Subdivision: I Lot no.: 1,000 sq.ft.or less 168.54 4 - Ea.add'I 500 sq.ft.or portion 33.92 I Tax map/parcel no.: Limited energy,residential 75.00 2 DESCRIPTION OF WORK (with above sq.fl.) Limited energy,multi-family 75.00 2 PV ROOF MOUNT residential(with above sq ft.) / Renewable Energy a .See Page 2 Services or feeders installation,alteration,and/or relocation ® PROPERTY OWNER I ❑ TENANT 200 amps or less 100.70 2 Name: - 201 amps to 400 amps 133.56 2 Gallagher,Scott A 401 amps to 600 amps 200.34 2 Address: .12270 SW Aspen Ridge Dr, 601 amps to 1,000 amps 301.04 2 Tigard OR 97224 Over 1.000 amps or volts 552.26 2 City/State/ZIP: g Temporary services or feeders installation,alteration,and/or Phone:( 503 ) 703 9677 Fax:( ) relocation 200 amps or less 59.36 I Owner installation:This installation is being made on property that I own which is not 201 amps to 400 amps 125.08 2 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 401 amps to 599 amps 168.34 2 Owner signature: Date: Branch circuits--new,alteration,or extension,per panel ® APPLICANT I ® CONTACT'ransoN A.Fee for branch circuits with above service or feeder fee, 7.42 2 Business name:SOLAR CITY each branch circuit B.Fee for branch circuits without Contact name:MELISSA BENTLEY service or feeder fee,first 56.18 2 branch circuit Address:6132 NE 1 127"AVE Each add''branch circuit 7.42 I _ 2 City/State/ZIP:PORTLAND OR 97220 Miscellaneous(service or feeder not included) Each manufactured or modular dwelling,service and/or feeder 6714 2 Phone:(503)894-6903 Fax::(1866)445-7459 Reconnect only 67.84 2 E-mail:ABENTLEY@SOLARCITY.COM Pump or irrigation circle 67.84 2 CONTRACTOR Sign or outline lighting 67.84 2 Business name:SOLAR CITY Signal circuit(s)or limited-energy See panel,alteration,or extension. Page 2 2 Address:6132 NE 112TH AVE Each additional inspection over allowable in any of the above Additional inspection(I hr min) 66.25/hr City/State/ZIP:PORTLAND OR 97220 Investigation(1 hr min) 66.25/hr Phone:(503)8944903 I Fax:(188)445-7459 Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 180498 I Electrical Lic.: C562 Suprv.Lic.: 5201S specifically hr fically listed(Si hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name: DEREK CROPP Date: 8/01/14 Plan review(25%of permit fee): ■ _ State surcharge(12%of permit fix): Authorized signature: I 1 i ' TOTAL PERMIT FEE: This permit application expires if a permit 6 not obtained within 180 Print name: A. MELI 'A : T t Date: 8/01/14 days after it has been accepted as complete • Number of inspections allowed per permit. tlmuildieeermisELC-PermApp-ELR-EREdoe Rev OS/11/2013 440.461ST(IIIO55COM/WEB I Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: FtEl:SC tEDtJi.E Fee for all residential systems combined $75.00 D l ate. 1 H� l 'nw f" eurtntiea Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 $133.56 2 n Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 n Burglar Mann Wind generation systems in excess of 25 kva: 25.01 to SO kva 301 04 2 I I Garage Door Opener* 50.01 to 100 kva 552.26 2 100 kva(fee in accordance with 552.26 ❑ Heating, Ventilation and Air Conditioning OAR 918-309-0040) System* Solar generation systems In excess of 25 kva: Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100I a no additionalcltur'e 0.0 3 Each additional inspection over allowable in any of the above:_ n Other: Each additional inspection is changed at an hourly(1 hr min) 6625/hr Inspections for+which no fee is 90.+10!hr specifically listed . hr min)GUmMtgOAL ±.ALEcro.ic,Ax,intbirr FEES Fee for each commercial system $75.00 Subtotal: (SEE OAR 918-309-0000) Plan review,if required(25%of permit fcc): State surcharge(I2".0 of permit fee): Check Type of Work Involved: TOTAL PERMIT PEE: Stereo permit applicatlen expires if a permit is not obtained within ISO DAudio and Stereo Systems days after it has been accepted es complete. Number of inspections allowed per permit. n Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation n intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical n Nurse Calls ❑ Outdoor Landscape Lighting* n Protective Signaling ❑ Other Total number of'commercial systems: *No licenses are required. Licenses are required for all other installations 11BuddmgJ•cr. [IsELC_PermiApp_ELIt_t,ati rim Rev 05/21,201' City Tigard Ti and RECEIVED • Building Division 4 2014 r■ 13125 SW Hall Blvd, Tigard, OR 97223 AUG Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TIGARD TIGARD Inspection Line: 503.639.4175 BUjj,pING DIVISION www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12270 SW Aspen Ridge Dr, City: TIGARD Zip: 97224 . Owner's Name: Gallagher, Scott A Date: 8/1/14 Contractor's Name: SOLAR CITY CCB #: 180498 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation es qualify for the Located in a flood prescriptive path, follow Area plain/flood way? ® No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? • dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above ❑ No 1 I:Building/Fortes/PhotoVoltaic-Checklist.docx • Is the construction material wood and does ® Yes Type of "Yes",the construction qualify If qualifies for Construction El the prescriptive path. as"conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes",qualifies for with Section 305.4(3)of the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofmg material shingle/shake checked,qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted Yes Connections of solar assembly „ the solar assembly connected to roof If"Yes”,qualifies f ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? q ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes",qualifies for ❑ Yes the prescriptive path. No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches,qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, I Yes decking connected to If"Yes",qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No IBuilding/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules . Manufacturer: TRINA SOLAR Model Number: TSM-250PA05.18 Listing Agency: UL1703 4 I:Building/Forms/PhotoVoltaic-Checklist.docx ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE AUG 4 2014 CONC CONCRETE HAZARDS PER ART. 690.17. CITY OF TIGARD DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE REVIEWED FOR CODE COMPLIANCE CITY OF TIGARD EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. Approved: [1---r--- BUILDING DIVISION EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTING OTC: I FSB Fire Set-Back LABORATORY SHALL LIST ALL EQUIPMENT IN GALV GALVANIZED COMPLIANCE WITH ART. 110.3. Permit#: 1kAZ� (4--CC's (2 GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL Address: tz7 7 d<A6 T IOP(IY- GND GROUND COMPLY WITH ART. 250.97, 250.92(B) HDG HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER Suite#: I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS OR By Date: I Pi l.-Z- Imp CURRENT AT MAX POWER ENCLOSURES TO THE FIRST ACCESSIBLE DC Isc SHORT CIRCUIT CURRENT DISCONNECTING MEANS PER ART. 690.31(E). 1 kVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN kW KILOWATT LBW LOAD BEARING WALL UL LISTING, LIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY OFFICE COPY MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT THE . (N) NEW UL-LISTED LOCATION PROVIDED BY THE NEUT NEUTRAL MANUFACTURER USING UL LISTED GROUNDING NTS NOT TO SCALE HARDWARE. . OC ON CENTER 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINE BONDED WITH EQUIPMENT GROUND CONDUCTORS AND P01 POINT OF INTERCONNECTION GROUNDED AT THE MAIN ELECTRIC PANEL. PV PHOTOVOLTAIC 9. THE DC GROUNDING ELECTRODE CONDUCTOR SCH SCHEDULE SHALL BE SIZED ACCORDING TO ART. 250.166(B) & SS STAINLESS STEEL 690.47. STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT - - - .— i-: • - 3R NEMA 3R, RAINTIGHT ` - v• SW'BU��'MCUfltaln Rd' PV1 COVER SHEET ; _s1 ti _ ,� it , PV2 SITE PLAN T, 4 ;;,,-,�p,1 , ,_� i∎ , i=i - f , . • • •: _ PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS . ''0 - :• - ? PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES T {. ,- ,h �' .-� • w ,ti_ • . .r% PV6 ELECTRICAL CALCULATIONS "'"' ` -.r' Cutsheets Attached 1. THIS SYSTEM IS GRID-INTERTIED VIA A .• n ' . �► OR # 180498 - '..,*1 /� - __` ; RGC, CGC1 UL-LISTED POWER-CONDITIONING INVERTER. �`"- ►... = �•.'><.<, .Y c _ + " 'a" W..1._ • ,�r r `� 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. -�" ' .. -'• ' ! • #,. • 3. SOLAR MOUNTING FRAMES ARE TO BE '` T r• GROUNDED. �� , r '� � rd.. '�d-� 4. ALL WORK TO BE DONE TO THE 2010 OBC . • '! "t r, MODULE GROUNDING METHOD: ZEP SOLAR BASED ON THE 2009 IBC. �' ' '; ` ' - Nr• 5. ALL ELECTRICAL WORK SHALL COMPLY WITH � +�r' '�' ` '`r"' �++ s. e. .4, AHJ: Tigard • ��! , ��� . ;4 �. 1'�^` �REV BY DATE COMMENTS 9 THE CURRENT NATIONAL ELECTRIC CODE ASY'• _ .� - t7,ee DATE COMMENTS• AMENDED BY THE OREGON ELECTRICAL SPECIALTY - " v '� ®® CODE. ' at s '0,..- 1,.../ . `,� �,.. '" Ali"x'' ©®® ' Portland General Electric ""�` UTILITY: Co It ; s- �"• -•a►a► . ®NCetro 're cfl O n. Sta " ", d rl~go State of Oregt.$. Geological purvey©� • CONFIDENTIAL — THE INFORMATION HEREIN NUMBER: J B—9 7 2 2 0 3 7 00 PREMISE OWNER: DESCRIPTION: DESIGN: I CONTAINED SHALL NOT BE USED FOR THE GALLAGHER, SCOTT A GALLAGHER RESIDENCE Matt Yamamoto ����So�a�Cit J1 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �I,`J 1 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12270 SW ASPEN RIDGE DR 5.61 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH TIGARD, 3055 Clearvew Way THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN Z PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: 5037039677 PV 1 7/25/2014 T:(t 50)638-1028 F:(650)638-1029 POWER-ONE ; AURORA PVI-5000-OUTD-US-Z-A COVER SHEET (888)-sa aTY(765-2489)www.solarcit.corn PITCH: 24 ARRAY PITCH:24 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 • s-it'1 MATERIAL: Comp Shingle STORY: 2 Stories 12 270 SW Aspen Ridge Dr ,,,` **N■ row 91∎44.1l Front Of House i■Vii14■■ (E) DRIVEWAY /.`. ..- /\ • LEGEND ® (E) UTILITY METER & WARNING LABEL ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS V-1 DC DISCONNECT & WARNING LABELS ■ Locked Gated 0 ❑ [— U — — u _ _ u Fir�o etbaCk u — U U 0 0 0 0 0 0 �.H AC DISCONNECT & WARNING LABELS !-lq O DC JUNCTION/COMBINER BOX & LABELS 1 ' ' I O DISTRIBUTION PANEL & LABELS F"--I . Le LOAD CENTER & WARNING LABELS a) _ 41110 E O DEDICATED PV SYSTEM METER M o STANDOFF LOCATIONS • CONDUIT RUN ON EXTERIOR __ ___, --- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED A r, -i I% ;" INTERIOR EQUIPMENT IS DASHED L_1 SITE PLAN N TOTAL ARRAY AREA (SF): 396 Scale: 1/8" 1' �, TOTAL ROOF AREA (SF): 1007 = w `+ E TOTAL ARRAY AREA IS a 39.28 0 1' 8' 16' PERCENT OF TOTAL ROOF AREA lillaimilimi s CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE J B-9 7 2 2 0 3 7 0 0 GALLAGHER, SCOTT A GALLAGHER RESIDENCE Matt Yamamoto �`,t, SolalCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �•.,,: - NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12270 SW ASPEN RIDGE DR 5.61 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clear'lew Way THE SALE AND USE of THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN Z PAGE NAME: SHEET: REV: DATE: San Moteo, CA 94402 PERMISSION OF SOLARCITY INC. 'RIOTER: 5037039677 PV 2 7/25/2o14 T:(65O) 638-1028 F:(65O)638-1029 POWER-ONE # AURORA PVI-5000-OUTD-US-Z-A SITE PLAN (888)-SOL-CITY(765-2489) www.solarcity.com (E) 2x4 0 PRE-MANUFACTURED TRUSS 9 STRUCTURE MEETS THE 't PRESCRIPTIVE REQUIREMENTS -y' 1! 9'-1" 1 8' / OF THE OSISC SECTION 305.4 1'—4! (E) LBW SIDE VIEW OF MP1 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" TOP CHORD 4x4© 24"OC ROOF AZI 180 PITCH 24 STORIES: 2 ARRAY AZI 180 PITCH 24 BOT CHORD 2x4 @24"OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) ---___. HOLE. (4) — SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. ZEP FLASHING C .�=�,`W�� �� (3) INSERT FLASHING. �� .(E) COMP. SHINGLE -o■I ■-• ■;■Pr" (4) PLACE MOUNT. (E) ROOF DECKING INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) ) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES ---- INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER STANDOFF • 41) Scale: 1 1/2" = 1' CONFIDENTIAL – THE INFORMATION HEREIN J0 J B—9 7 2 2 0 3 7 00 PREMISE OWNER: DESCRIPTION: DESIGN: 8 NUMBER: Matt Yamamoto '4%‘,\ ,,`SolarCity. CONTAINED SHALL NOT BE USED FOR THE GALLAGHER, SCOTT A GALLAGHER RESIDENCE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •.,: - NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12270 SW ASPEN RIDGE DR 5.61 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULEP TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH ' 3055 CleaMew Way THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN Z PAGE NAME: SHEET: / REV. DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER. 5037039677 P V 3 7/25/2014 T'(650)638-1028 F:(650)638 102 _ POWER-ONE _# AURORA PVI-5000-OUTD-US-Z-A STRUCTURAL VIEWS (see)–soL–CITY(765-2489) www.solarcit.com UPLIFT CALCULATIONS 07.25.2014 SolarCity SleekMount"' PV System Version*37.7 Structural Desian Software Project Information&Table Of Contents Risk Category: Il PV System Type SolarCity SleekMount"" Comp Roof Comp Roof Layers of Comp Roofing 2 Roof Slope 24° Rafter Sparing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 388 sf PV Module Width 39" PV Module Length 65" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 25.0 psf 'ASCE Tale 7-1 Surrounding Roof Snow 100% 25.0 psf 'ASCEliii7Al4 Roof Snow Over PV Modules 100% 25.0 psf .ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 I Wind Design Method Partially/Fully Endosed Method Basic Wind Speed V 95 mph i Fig.6-1 Exposure Category C ' Section 6.5.6.3 Roof Style Gable Roof •Fig.6-118/C/0-14A/B Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Veiodty Pressure qh qh = 0.00256(1(z)(Kit)(Kd)(V^2)(I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-118/C/D-14N8 Ext.Pressure Coeffident(Down) GCp(Down) 0.45 Fg.6-118/C/D-14N8 Design Wind Pressure P p=qh(GCp) Equation 6-22 Wind Pressure Up p(up) -16.3 psf Wind Pressure Down p(down) 10.0 psf Allowable Standoff Spacings X-Direction Y-Direction Max Allowable Standoff Spadng Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff 7-actual -285 lbs Uplift Capadty of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 57.0% Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered • Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -316 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capadty - OCR _ 63.3% CONFIDENTIAL- NE INFORMATION HEREIN J13-9722037 NDMBER: 0 0 PREMISE OWNER DESCRIPTION: DESIGN:GALLAGHER RESIDENCE \.�, CONTAINED SHALL NOT BE USED FOR NE GALLAGHER, SCOTT A Matt Yamamoto � ,SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: - NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12270 SW ASPEN RIDGE DR 5.61 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 3055 OC°*"Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: T:(650)638-1028 n ,CA sue 638-1029 PERMISSION OF SOLARCITY INC. POWER—ONE # AURORA PVI-5000-OUTD-US-Z-A 5037039677 UPLIFT CALCULATIONS PV 4 7/25/2014 (888)-SQL-PTY(7s5-2489)www.adardtycom GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number: Inv 1: DC Ungrounded OR # 180498 INV 1 -(1)POWER-ONE # AURORA PVI-5000- UTD S-Z-A -(22)TRINA SOLAR # TSM-255PA05.18 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:23126291 AFCI Inverter; Zigbee 5000W, 277V/240V/208V, 96.5%/96.5%/96% PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL (E) 200A/2P MAIN CIRCUIT BREAKER (E) WIRING COOPER CUTLER-HAMMER Inverter 1 IND i 200A 2P Meter Socket Disconnect Q3 POWER-ONE 1 pc DO NOT ADJUST MIN.ACTIVATION V LTAGE / AURORA PVT-5000-0UTD-US-Z A DC- 1 String(s)Or 11 On MP 1 �� (E) LOADS A B �__ EGC � J • � n o I iaav I I- I d----tr- • I ■~• 1 �_ - Lz ✓ Dc. I ` N =Lip,— DD DO NOT ADJUST MIN.ACTIVATION V TAGS 30A/2P -I GND eNp _ EGG/ -- .� DC- DC- Z /— GEC lO �� DC_ DC- EGC 1 Stnng(s)Of 11 On MP 1 m�/� ■ tl I ®-___EGC—__ ___ _ EGC -E I 1 Conduit Kit; 1- EMT N J_ _ I I J EGCIGEC _j c ---- z—z c-7 — T GEC 1 TO 120/240V SINGLE PHASE UTILITY SERVICE I II Voc* = MAX VOC AT MIN TEMP POI_(1)CUTLER-HAMMER # BR230 PV BACKFEED BREAKER A —(1)COOPER N B-Line Meter Socket 011 /r,H D� Breaker, 30A 2P, 2 Spaces Meter Socket; 125A, 4-14AWG, Ring Type - 1 AW CAP; B-Line Meter Socket Accessory (1)Milbank)CL200D /Itron CIS Solid-State Single-Phase Meter; Digital B (1)CUTLER-HAMMER /DG221URB Disconnect; 30A. 240Voc, Non-Fusible, NEMA 3R -(1)CUTLER-HAMMER I DGO3ONB Grand/Neutral Kit; 30A, General Duty(DG) (1)AWG/10, THWN-2, Black - - (2)AWG {IT10, PV WIRE, Black Voc* =465.13 VDC Isc =8.92 ADC © (1)AWG/10, THWN 2, Red O a0L-(1)AWG/6, Stranded Bore Copper EGC Vmp =335.5 VDC Imp=8.36 ADC (1)AWG #10, THWN 2, White NEUTRAL Vmp =240 VAC Imp=23 MC (1)Conduit Kit; 3/4- EMT . . . -(1)AWG /8, THWN-2. Green. . _ EGC/GEC.-(1)Conduit,Kit:.3/4',EMT, . . _ _ . , . . . O La�(2)AMIG (1 0, PV WIRE, Black Voc* =465.13 VDC Isc =8.92 ADC (1)AWG#6, Stranded Bare Copper EGC Vmp =335.5 VDC Imp=8.36 ADC (1)Conduit Kit; 3/4' EMT CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-9722037 00 ��A CONTAINED SHALL NOT BE USED FOR THE GALLAGHER, SCOTT A GALLAGHER RESIDENCE Matt Yamamoto `'?''-SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: .,r NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12270 SW ASPEN RIDGE DR 5.61 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS P I,` ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 3055 Clearriew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN Z Z PAGE NAME: SHEET: REV DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: 5037039677 PV 5 7/25/2014 T:(650) 638-1028 F:(650)638-1029 POWER—ONE # AURORA PVI-5000—OUTD-US—Z—A THREE LINE DIAGRAM (666)-soL-CITY -2489) www.solarcity.com ELECTRICAL CALCULATIONS Module i 22 TRINA SOLAR#TSM 255 ZEP 232.2 Inv Power WPTC Voltage Drop Calculations Version 5.8.0 Inverter 1: 1 Power One PVI 5000 S AFCI 0.965 5000 4929.61 Vdrop= (Imp) * (2*Length)*(Resistance) / (Vmp) . Module: Imp(A) Max. Length(ft) Wire Inverter 2: String: 8.36 80 AWG_10 at Max Ave Hi:87 deg F • Module: Vdrop= (8.36 * 160 *0.001240hms) / 276.35135 0.6 Inverter 3: Branch: 1 8.36 I 50 1 AWG_10 I at Max Ave Hi:87 deg F Module: - Vdrop= (8.36 * 100 *0.001240hms) / 276.35135 0.38 Inverter 4: Total voltage drop in DC conductors= 0.98 - Inverter: 1 8.36 I 20 I AWG_10 at 240V Vdrop= (8.36 *40 *0.0012 Ohms) / 240 V 0.1672 Total: 22 Modules Total Inv Pwr: 5000 4929.61 PTC Combined:I 0 I 0 I AWG_10 at 240V Photovoltaic Module Electrical Specifications: Total STC: 5610 Vdrop= ( 0 * 0 0.0012 Ohms) / 240 V 0 Voc: 37.7 V deg F deg C Vmp: 30.5 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.17 Isc: _8.92 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 1.14 Imp: 8.36 A Record Hi Temp: 96 36 Tvoc: -0.12064 V/deg C Tisc: 4.1924 mA/deg C I String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch CircuitType A 1 way wire length: 50 Voc Correction Factor: Power-One_PVI-5000-S AFCI . 1 I strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input 120 11 TRINA SOLAR#TSM-255 ZEP 11 I modules per series string 11 I modules per series string Voc= 414.7 Min Vmp at Max Temp: 276.35 Voc= 414.7 V Voc= 414.7 V Max Voc at Min Temp: 465.13 Vmp= 335.5 Vmp= 335.5 V Vmp= 335.5 V Inverter Max Vdc Input: 600 Isc= 8.92 Isc= 8.92 A Isc= 8.92 A Imp= 8.36 Max String Size. 14 Imp= 8.36 A Imp= 8.36 A 1-way wire length: 80 Icont= 11.15 Art 690.8(A)(1) Icont= 11.15 A Icont= 11.15 A Art 690.8(A)(1) 1.a Conductor: AWG_10 J PV Wire 2.a Conductor 1: AWG_10 Conductor 2: AWG_10 lcont*1.25=(Amps) 13.94 I Conductor 1 Conductor 2 30 deg C ampacity= 40 Icont*1.25=(Amps) 13.94 13.94 1.b Icont=(Amps) 11.15 30 deg C ampacity= 40 40 Start ampacity 40 2.b Icont=(Amps) 11.15 11.15 Temperature derate(%=F) 0.76 Start ampacity 40 40 Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.76 0.76_ Derated ampacity 30.4 I Conduit fill derate(%=#) 0.8 0.8 1 C Derated ampacity 24.32 24.32 I Icont* 1.25=(Amps) 13.94 2.c Term 1 Term 2 Ampacity 40 Temp table 75degC 75degC 1.d Icont`1.25=(Amps) 13.94 Icont*1.25=(Amps) 13.94 13.94 OCP Size= 15 Ampacity 35 35 I Inverter Type A Output 2.d OCP Size= I 15 I 15 I Power-One PVI-5000-S AFCI 1 way wire length: 10 ft Combined Inverter Output Icont= I 23 I A Art 690.8(A)(1) Service Voltage= 3.a Icont* 1.25=(Amps) 28.75 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 0 OCP Size= 30 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG_10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) Icont'1.25 (Amps) 28.75 4.a Icont*1.25=(Amps) 28.75 Art 690.8(B)(1) 30 deg C ampacity= 40 I OCP size= 30 Art 240.6(A) 3.c Icont=(Amps) 23 4.b Conductor: I AWG_10 THWN-2 at 90 deg C:Table 310.16 Start ampacity 40 Icont*1.25=(Amps) 28.75 Temperature derate(%=F) 0.91 30 deg C ampacity= 40 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 23 Derated ampacity 36.4 Start ampacity 40 3.d Icont* 1.25=(Amps) 28.75 Temperature derate(%=F) 0.91 Ampacity 35 Conduit fill derate(%=#) 1 Derated ampacity 36.4 4.d Icont* 1.25=(Amps) 28.75 Ampacity 35 I CONFIDENTIAL - THE INFORMATION HEREIN JO8 NUMBER: J B-9 7 2 2 0 3 7 00 PREMISE OWNER: DESCRIPTION: DESIGN: ..,� ■ CONTAINED SHALL NOT BE USED FOR THE GALLAGHER, SCOTT A GALLAGHER RESIDENCE Matt Yamamoto -- SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ;•... NORTSH OTHERS DISCLOSED I RECIPIENTS IN Comp Mount Type C 12270 SW ASPEN RIDGE DR 5.61 KW PV ARRAY ORGANIZATION, EXCEPT IN CONNECTION MATH MODULES TIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (22) TRINA SOLAR # TSM-255PA05.18 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650)638-1028 F:(650)638-1029 POWER-ONE # AURORA PVI-5000-OUTD-US-Z-A 5037039677 ELECTRICAL CALCULATIONS PV 6 7/25/2014 (888)-soL-aTY(765-2489) www.sdarcity.com Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC) (P01) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 SECOND SOURCE IS NEC 690.64.B.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC) (INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER _A (DC)(INV) UNGROUNDED AND INVERTER IS POINT CURRENT(Imp) Per Code: MAY BE ENERGIZED UNGROUNDED MAXIMUM POWER-_V NEC 69053 POINT VOLTAGE(Vmp) 690.53 MAXIMUM SYSTEM Label Location: VOLTAGE(Voc) WARNING (AC) (POI) SHORT-CIRCUIT Per Code: CURRENT(Isc) A ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.B.7 DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC) (INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD, DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC Label Location: A OPERATING CURRENT (AC): AC Disconnect PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC _ (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D) (POI) (LC): Load Center Per Code: (M): Utility Meter PHOTOVOLTAIC SYSTEM NEC 690.64.B.4 CIRCUIT IS BACKFED (P01): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR lib 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �. San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - OR Label Set T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE l'/,�r�.So I a rC qty (888)-SQL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. 0 c ZS Comp Edge Zone Calculations 1 of 4 0 ZS Comp Edge Zone Calculations 2 of 4 Zep Sola C 5/28/13 Zep Solar 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing= module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs - -R. 401 note:use 10 psf minimum firr ;4► ,'� Snow Calculations Attachment Spacing Calculations 85818 I To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing p OREGON a lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes .v 5v above 30 degrees. Allowable Uplift Load FRvv.10ROOf.. uplift spacing= module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 p=qh GCN Design Snow Load 29.11 25.98 psf qh=0.00256 K,K„Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone - Combinations: 14 30 Importance Factor= 1.0 K,= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof Kzt= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf lorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 iscape effective area= 13.0 ft2 GCN portrait= -1.5 1147lbs in 2 landscape down force spacing = 39"x 32.46psf x 144 ftz = 130" ortrait effective area= 21.7 ft2 landscape= -30.79 psf qh= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ftz =78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) ' design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in • landscape uplift spacing = 39"x 29.05 psf x 144 ftz =83" 656 lbs in portrait uplift spacing = x 144 65"x 27.12 psf ft2 = 54" 0 ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 Zep Sola r 5/28/13 Zep So la r 5/28/13 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing= -1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing= -1.4545 x 32.46 psf+120.7273 =73" ps=Cs Pf Roof Pitch= 31 45 degrees Pf=0.7 Ce Ct l pg Ce= 0.9 Cs= 0.71 0.45 G= 1.2 pf= 22.68 22.7 psf portrait module spacing =-1.7917 x 32.46 psf+118.58=60" I= 1.0 p5= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait • 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) Lateral 30° 27° 30° 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755. 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 2921bs in landscape lateral spacing = 39"x 14.49 psf x 144 ft2 = 74" 292lbs in portrait lateral spacing= x 144 65"x 14.49 psf ft2 =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = 65"x 13.50 psf x 144 ft2 =48" SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep Compatible"'modules r aesthetics while minimizing roof disruption and • Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" ` • Insert Comp Mount flashing under upper utilizes Zep Compatible"' modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs,effectively eliminating the • Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition • Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions • • Secure Leveling Foot to the Comp Mount using machine Screw �—; 9 • Place module c • Components � � I if* I �. • 5/16"Machine Screw jai • Leveling Foot • • CD 41 Lag Screw Q • Comp Mount rte • • • Comp Mount Flashing s a `. njrA • • iliCit ® It cOMVAlB w„�� iA 0,10 ink • :,, SolarCity® January 2013 LISTED SolarCity �oMP'�. ® January 2013 I • TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE 4 Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DAM 04,STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PAOS.18 PA05.18 941mm Peak Power Watts-P.n.s.(Wp) 240 245 250 255 260 Power Output Tolerance-PMA.(%) 0/+3 0/+3 0/+3 0/+3 0/+3 ,,,,x„- o, Maximum Power Voltage-Vi,(V) 29.7 30.2 30.3 30.5 30.7 ° eox o Maximum Power Current-1.1T(A) 8.10 8.13 8.27 8.36 8.47 TSNI - PAO5 .1 8 ����.ir ° Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 iii msrurwcr,orr Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 g Module Efficiency nm(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE 3 STC:Irradiance 1000 W/m',Cell Temperature 25°C.Air Mass AMI.5 according to EN 60904-3. E Average efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. ° 3 3 ELECTRICAL DATA NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL Maximum Power-P..(Wp) 174 178 181 184 188 Maximum Power Voltage-V.,P(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE n,., „N •2,ar A A Maximum Power Current-Iim,(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME /Q0AA1N001 F Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 ) 812mm 1 180 I NOCT:Irradiance at 800 W/m'.Ambient Temperature 20°C,Wind Speed I m/s. • 240-260W Back View POWER OUTPUT RANGE DATA Our most versitile product I.11 � • Compatible with all major BOS components and system - Solar cells Multicrystalline 156 x 156 mm(6 inches) designs Cell orientation 60 cells(6 x 10) 1 o Module dimensions 650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) v lO Weight 18.6 kg(41.0Ibs) MAXIMUM EFFICIENCY Glass High transparency solar glass 3.2 mm(0.13 inches) Backsheet White One of the industry's most trusted modules • Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Alloy with Trinamount Groove 0,,, S v7O • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-Box IP 65 or IP 67 rated J/ Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), lo.m - - 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9m - 1000 m 8m Connector Original MC4 7m 800W/m2 Highly reliable due to stringent quality control f \MU 5m As a leading global manufacturer • Over 30 in-house tests(UV,TC,HF,and many more) 4m :: _�= TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic t - • In-house testing goes well beyong certification requirements ae \1� products,we believe close 2m 2 W/m2 mi. Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C P _ " \1 M Temperature(NOCT) Maximum System 1000V DC cooperation with our partners om MVO (EC)/ is critical to success. With local 0.m lam tam 3pm 40m Temperature Coefficient of Po. -0.43%/°C Voltage 600V DC(UL) presence around the globe,Trina is voRope(V) Temperature Coefficient of Vox -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service Temperature Coefficient of Isc 0.047%/°C to each customer in each market - and supplement our innovative, Certified to withstand challenging environmental reliable products with the backing conditions of Trina as a strong,bankable • 130 km/hr wind load(2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module (5400 Pa) tO year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors (Please refer to product warranty for details) and other partners as the backbone of our shared success in CERTIFICATION driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY ( PACKAGING CONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty \ �w -u spa Modules per box:24 pieces Trina Solar Limited www.trinasolor.com `v 100% ISO loft (E Om w-Y� Modules per 40'container.672 pieces Additional u ,, r MU Value 0 90% fro Trina Solor'x linear Warranty CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. rof4F4>i • a a 2013 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to tie B:. • Tr'nasolar L7 80% change without notice. Tr�nasolar g Smart Energy Together rears s o s 20 25 Smart Energy Together , rem eMP• . :, ■ Trina Solar I • r\ power-one z • TECHNICAL DATA VALUES PVI-5000.OUTD-US PVI-6000-OUTD-US \,.,1 Renewable Energy Solutions D Nominal Output Power W 5000 6000 0 Maximum Output Power W 5000 6000 Rated Grid AC Voltage V 208 240 277 208 240 277 PVI-5000-TL < Input Side(DQ Number of Independent MPPT Channels 2 2 Maximum Usable Power for Each Channel W 4000 41X10 P VI-6 0 0 0-T L Absolute Maximum Voltage(Vmax) V 600 600 •;}` Start-Up Voltage(Vstart) V 200 (adj.120350) 200 (adj.120-350) '. Full Power MPPT Voltage Range V 200-530 200-530 • Operating MPPT Voltage Range V 0.7xVstart-580 0.7hVstart-580 >:. - - Maximum Current Wanes)for both MPPT in Parallel A 36 36 . ,.F' ° Maximum Usable Current per Channel A 18 18 •-. 9 Maximum Short Circuit Current limit per Channel A 22 22 GENERAL SPECIFICATIONS T Number of Wire landing Terminals Per Channel 2Pain 2Pals rN y Array Wiring Termination Terminal block,Pressure Clamp,AWG8-AWG4 rrx��� Output Side IAq _ ' .k ] Grid Connection Type 10/2W Split-0/3W 10/2W 10/2W Split-013W 10/2W I ( tr sa AdjustableVoltage Range)Vm in-Vmax l V 1B3-228 211-264 244304 183-228 211-264 244-304 °° z>j ? Grid Frequency Hz 60 60 1:1.1.41...:..7',.) _ Adjustable Grid Frequency Range Hz 5760S 57-60.5 Maximum Current(lacmax) Aims 27 23 20 30 28 24 • •f.'; Power Factor >0.995 >0.995• . :1 Total Harmonic Distortion At Rated Power % <2 <2 • s_ Contributory Fault Current*' Ao/Aims 3625/25.63 36.5/2581 31.75/22.45 36.25/25.63 36.5/25.81 31.75/22.45 Designed for residential and small commercial PV installations,this . • Grid Wiring Termination Type Terminal block.Pressure Clamp,AWG8-AWG4 inverter fills a specific niche in the Aurora product line to cater for ti' Input ten bevies Input those installations producing between 5kW and 20kW. •- - Reverse Polarity Protection Yes Yes Over-Voltage Protection Type Varistor,2 for each channel Varistor,2 for each channel PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI Pre start-up Riso and dynamic GFDI This inverter has all the usual Aurora benefits,including dual input (Requires Floating Arrays) (Requires Floating Arrays) Output section to process two strings with independent MPPT,high speed • • Anti-Islanding Protection Meets UL 1741AEE1547 requirements Meets UL 1741/IEE1547 requirements and precise MPPT algorithm for real-time power tracking and Over-Voltage Protection Type Varistor,2(Li-L/L-G) Varistor,2(L-L/Li-G) Maximum AC OCPD Rating A 35 30 25 40 35 30 energy harvesting, as well as transformerless operation for high Emciency performance efficiencies of up to 97.1%. Maximum Efficiency % 97.1 97.1 • . CEC Efficiency 96 96 96.5 96.5 96 96.5 96.5 • Operating Performance The wide input voltage range makes the inverter suitable to low Stand-by Consumption Ww"r <8 <8 • ` ' -- ` -` Night time consumption Wxvs <Ob <0.6 power installations with reduced string size.This outdoor inverter ♦ Corot timec consumption has been designed as a completely sealed unit to withstand the - - -: User-Interface 16 characters x 2 lines LCD display harshest environmental conditions. Remote Monitoring Ii iRS485 incl.) AURORA-UNIVERSAL(opt.) Wired Local Monitoring(txRS485 incl.) PVI-USB-R5485_232(opt.),PVI-DESKTOP(opt.) Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) Environmental Ambient Air Operating Temperature Range °F CC) -13 to+140(-25 to+60) -13[a+140(25 to+60) with denting above 122(50) Ambient Air Storage Temperature Range °F(°C) -40 to 176(40 to+80) 40 to 176(-40 to+80) Relative Humidity %RH 0-100 condensing 0-100 condensing Acoustic Features ..um Oise atingiAlt Level db ft(m) <(2 50 0(2 50 s Maximum Operating Altitude without berating ft(m) 6560(2000) 6560(2000) Mechanical Specifications ;' ,y;' A'•`. Enclosure rating NEMA4X NEMA4X = Cooling Natural Convection Natural Convection • Each inverter is set on specific grid codes which can be selected in the field ' Dimensions IHxWxD) in(mm) 41.4 x128x8.6(1052x325x218) ••Single phase output 5: ( t Weight lb(kg) <59.5(27.0) <59.5(27.0) 9 P P Shipping Weight lb(kg) <78(35.4) <78(35.4) • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented '44 i• Mounting System Wall bracket Wall bracket • '-rq, .,x Trade Size Kos:(2ea x 1/2') Trade Size Kos:(tea x 1/2') in different directions conduit connections -_ and(2ea x 1-1/4;3 places side,front,rear) and(2eax 1-1/4;3 places side,front,rear) •Wide input range z DC Switch Rating)Per Contact) MI 25/600 25/600 sac • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting > Isolatyon Level Transformedess(Floating Array) Transfamedess(Floating Array) • • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance y? Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01,U11998 U116998, UL 1741,CSA-C222 N.107.1-01,UL1998 UL1r,998 i 'rt'g-`;,- FCC Pan 15 Class FCC Part 15 Class across the entire input voltage and output power range Safety Approval ,csA,. ,CSA. •Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions s , Warranty „f t I. Standard Warranty years 10 10 • RS-485 communication interface(for connection to laptop or datalogger) ` Extended Warranty years 15&20 15&20 • 'a's AvaIlable Models Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP k��`�:• •Into rated Arc Fault Detection and Interruption(-A Version) Standard-With DC Switch-Floating Array PVI50000UTD US PVIfi000 OV1D•us Integrated P ( ) rt,x+,.:.tG i With DC Switch,Wiring box and Arc Fault Detector•4 PVI 500001JTD USA PVIfi0000UTD-US-A and Interrupter h „y y c. a • - . •- r a- Tr•xy: p. 'All data s subject to change without nonce•s fcss ,. S, y r t b fi+s .. ja r .' ...Inverter can apply that much current Breaker will open . 41 o ry .. a��f '�i�`'r"�, . r _ AURORA UN0 3• ?i 1, '; CSA INTERNATIONAL Certificate of Compliance Certificate: 1841082 Master Contract: 173688 Project: 2439384 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Rob-if esnpstack, Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 5311 09 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-6000-OUTD-US,PVI-6000-OUTD-US-W and PVI-5000-OUTD-US, permanently connected. For details related to rating,size,configuration,etc.reference should be made to the CSA Certification Record, Annex A of the Certificate of Compliance,or the Descriptive Report. APPLICABLE REQUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment For Use With Distributed Energy Sources(January 28,2010) DOD 507 Rev 2009-09-01 Page.I Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 12270 SW ASPEN RIDGE DR, TIGARD, OR, 97224 Residential - Master Permit 199 Electrical final PASS MST2014-00129 Jeff Grove Violation Summary: Inspector Contractor Location: Record Type: Inspection Type: Result: Comments: Inspection Date: Record ID: Inspector: City of Tigard 13125 SW Hall Blvd. Tigard, OR 97223 Tel: 503.718.2439 12270 SW ASPEN RIDGE DR, TIGARD, OR, 97224 Residential - Master Permit 299 Final inspection PASS - No C of O MST2014-00129 Jeff Grove Violation Summary: Inspector Contractor